HomeMy WebLinkAbout1891 RUTHERFORD RD; ; AS160261; Permit9/26/24, 2:27 PM AS160261 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160261 1891 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2121203600 Lot #: 0 Reference No.: Status: ISSUED Applied 8/18/2016 Approved: 8/30/2016 Issued: 8/30/2016 PC #: Inspector: Project Title: DNAE ELECTRONICS MODULAR CLEAN ROOM. EXISTING BUILDING HAS BEEN PREVIOUSLY SPRINKLERED WITH A COMPLETE, WET PIPE, AUTOMATIC FIRE SPRINKLER SYSTEM. "ADVANCE FIRE PROTECTION" TO EXTEND EXISTING SYSTEM TO PROVIDE SPRINKLER PROTECTION BELOW CEILINGS OF NEW MODULAR CLEAN ROOM. INTERSTITIAL PLENUM SPACE ABOVE CLEAN ROOM CEILINGS IS NON-COMBUSTILE AND REQUIRES NO SPRINKLERS. NEW CLEAN ROOM PROVIDES NO OBSTRUCTION TO EXISTING ROOF-LEVEL SPRINKLER PROTECTION. Applicant: Owner: PDG CARLSBAD 47&48 L P 1825 GILLESPIE WAY #102 EL CAJON CA L_Fees(s) fAdd Fees ($JTotal R Balance about:blank 1/2 9/26/24, 2:27 PM AS 160261 Permit Data IiIIIIIJIIIiio 325.5 0 about:blank 2/2 City of Carlsbad 08-30-2016 Fire Department Permit Permit No: AS160261 Job Address: 1891 RUTHERFORD RD CBAD St: 100 Permit Type: SPRINK Subtype: TI Parcel No: 2121203600 Lot #: 0 Fire Dept Ref#: AS160261 Building Permit#: cb162569 Location: Project Title: DNAE ELECTRONICS Description: MODULAR CLEAN ROOM. Contractor: ADVANCE FIRE PROTECTION Phone: 714-526-2231 1451 W. LAMBERT RD Fax: LA HABRA, CA 90631 Status: ISSUED Applied: 08/18/2016 Issued: 08/30/2016 Entered By: AR Total Fees: $325.50 Total Payments To Date: $0.00 # of Systems I # of Additional Risers or Floors 0 Plan Check Fee $0.00 Additional Plan Check Fee $112.50 #of Heads 0 $0.00 Permit Fee $0.00 Additional Permit Fee $71.00 Re-Inspection Fee 2 $142.00 ByPass Meter Fee $0.00 ByPass Addtl Meter Fee $0.00 Other $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $325.50 NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. a --- Fire Protection by Computer Design ADVANCE FIRE PROTECTION 1451 W. LAMBERT ROAD LA HABRA, CA 90631 562-691-0918 Job Name : DNA ELECTRONICS - CLEAN ROOM Building I Location : 1891 RUTHERFORD ROAD SUITE 100 CARLSBAD, CA System ENTIRE CLEAN ROOMS Contract 16-0502 Data File 16-0502-1.5.WXF AS1FILE COPY 60261 1891 RUTHERFORD RD 100 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ADVANCE FIRE PROTECTION Page 1 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 HYDRAULIC CALCULATIONS for Project name: DNAe ELECTRONICS Location: 1891 RUTHERFORD ROAD SUITE 100 CARLSBAD, CA Drawing no: 1 Date: AUG. 2016 Design Remote area number: ENTIRE CLEAN ROOMS Remote area location: ALL CLEANROOMS Occupancy classification: ORDINARY GROUP 2 Density: .2 - Gpm/SqFt Area of application: 2,2610 - SqFt Coverage per sprinkler: 130 S.F.MAX. - SqFt Type of sprinklers calculated: CONCEALED PENDENT K5.6 No. of sprinklers calculated: 29 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 1072.45 - GPM @ 77.75 -Psi Type of system: WET PIPE Volume of dry orpreaction system: N/A - Gal - Water supply information Date: 07/19/2016 Location: HYDRANT H61303 Source: CARLSBAD FIRE DEPT. Name of contractor: ADVANCE FIRE PROTECTION CO., INC. Address: 1451 W. LAMBERT RD LA HABRA, CA 90631 Phone number: 562-691-0918 Name of designer: RICK O'NEILL Authority having jurisdiction: CARLSBAD FIRE DEPT. Notes: (Include peaking information or gridded systems here.) THE SCOPE OF WORK IS THE ADDITION OF 29 SPRINKLERS IN ADDED CLEAN ROOMS. THE ORIGINAL SPRINKLER SYSTEM WAS HYDRAULICALLY CALCULATED FOR A DENSITY OF .45 GPM OVER A REMOTE AREA OF 3,000 SQUARE FEET. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C ADVANCE FIRE PROTECTION Page 2 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 City Water Supply: . Demand: Cl - Static Pressure : 126 Dl - Elevation : 6.063 C2 - Residual Pressure: 115 D2 - System Flow : 822.45 C2 - Residual Flow : 2000 D2 - System Pressure : 77.746 Hose ( Demand) : 250 D3 - System Demand :1072.45 Safety Margin : 44.781 150 140 130 P 120 R° E10° s90 D2 S80 U70 03 R6° -- ___ E5° 40 30 20 10 • I I I __________________________ 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary ADVANCE FIRE PROTECTION Page 3 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Fitting Legend Abbrev. Name 1/2 3/4 1 114 1V2 2 21,4 3 31/3 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I NFPA 1390 Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfc Febco 856 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fillings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD ADVANCE FIRE PROTECTION Page 4 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 0.0 66.18 na 3 0.0 66.18 na 5 0.0 66.18 na 6 0.0 48.0 na 7 0.0 46.81 na 8 0.0 46.83 na 10 0.0 66.2 na 11 0.0 48.8 na 12 0.0 47.63 na 13 0.0 47.64 na 15 0.0 66.23 na 16 0.0 41.75 na 17 0.0 39.2 na 18 0.0 39.07 na 19 0.0 39.33 na 21 0.0 66.27 na 22 0.0 44.2 na 23 0.0 42.29 na 24 0.0 42.26 na 25 0.0 42.41 na 27 0.0 66.23 na 28 0.0 45.19 na 29 0.0 43.47 na 30 0.0 43.45 na 32 0.0 66.22 na 34 0.0 66.21 na 36 0.0 66.21 na 38 0.0 66.2 na 40 0.0 66.2 na 6A 12.0 5.6 27.59 na 29.42 0.2 90 7.0 6B 12.0 5.6 28.69 na 29.99 0.2 90 7.0 6C 0.0 40.5 na 7A 12.0 5.6 26.81 na 28.99 0.2 90 7.0 7B 12.0 5.6 27.87 na 29.56 0.2 90 7.0 7C 0.0 39.5 na 8A 12.0 5.6 33.13 na 32.23 0.2 80 7.0 hA 12.0 5.6 25.61 na 28.34 0.2 90 7.0 11B 12.0 5.6 26.65 na 28.91 0.2 90 7.0 11C 0.0 38.15 na 12A 12.0 5.6 24.92 na 27.95 0.2 90 7.0 12B 12.0 5.6 25.91 na 28.5 0.2 90 7.0 12C 0.0 37.25 na 13A 12.0 5.6 32.78 na 32.06 0.2 80 7.0 16A 9.0 5.6 21.56 na 26.0 0.2 130 7.0 16B 9.0 5.6 22.57 na 26.6 0.2 117 7.0 16C 0.0 32.64 na 17A 9.0 5.6 20.33 na 25.25 0.2 117 7.0 17B 9.0 5.6 20.97 na 25.64 0.2 80 7.0 17C 0.0 30.63 na 18A 9.0 5.6 22.47 na 26.54 0.2 90 7.0 18B 9.0 5.6 22.13 na 26.34 0.2 80 7.0 18C 0.0 33.17 na 19A 9.0 5.6 27.08 na 29.14 0.2 80 7.0 22A 9.0 5.6 25.19 na 28.11 0.2 130 7.0 22B 9.0 5.6 26.17 na 28.65 0.2 104 7.0 22C 0.0 37.03 na 23A 9.0 5.6 23.97 na 27.42 0.2 130 7.0 23B 9.0 5.6 24.9 na 27.95 0.2 104 7.0 23C 0.0 35.44 na 24A 9.0 5.6 29.36 na 30.34 0.2 130 7.0 25A 9.0 5.6 29.47 na 30.4 0.2 130 7.0 28A 9.0 5.6 25.75 na 28.42 0.2 80 7.0 28B 9.0 5.6 26.75 na 28.96 0.2 80 7.0 28C 0.0 37.87 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard ADVANCE FIRE PROTECTION Page 5 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 29A 9.0 5.6 24.65 na 27.8 0.2 80 7.0 29B 9.0 5.6 25.61 na 28.34 0.2 80 7.0 29C 0.0 36.45 na 30A 9.0 5.6 23.05 na 26.89 0.2 130 7.0 30B 9.0 5.6 24.45 na 27.69 0.2 130 7.0 30C 0.0 35.95 na 50 0.0 66.47 na 2 0.0 56.59 na 4 0.0 56.58 na 9 0.0 56.57 na 14 0.0 56.57 na 20 0.0 56.57 na 26 0.0 56.58 na 31 0.0 56.62 na 33 0.0 56.71 na 35 0.0 56.76 na 37 0.0 56.8 na 39 0.0 56.81 na -. TR 0.0 67.25 na BR 0.0 67.75 na OH 0.0 68.46 na 250.0 DCA 0.0 70.11 na DCB 0.0 74.63 na CM -5.0 77.75 na - 13i-~( of- Rise The maximum velocity is 22.05 and it occurs in the pipe between nodes 6C and 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 6 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 -32.84 1.682 4T 39.599 254.000 66.180 to 120.0 0.0 39.599 0.0 2 -32.84 -0.0327 0.0 293.599 -9.592 Vel = 4.74 0.0 -32.84 56.588 KFactor= -4.37 3 -32.84 1.682 4T 39.599 254.000 66.180 to 120.0 0.0 39.599 0.0 4 -32.84 -0.0327 0.0 293.599 -9.596 Vel = 4.74 0.0 -32.84 56.584 K Factor = -4.37 5 -110.65 1.682 21 19.799 39.000 66.182 to 123.0 0.0 19.799 0.0 6 -110.65 -3.3091 0.0 58.799 -18.177 Vel= 15.98 6 59.42 1.682 0.0 16.000 48.005 to 120.0 0.0 0.0 0.0 -51.23 -0.0744 0.0 16.000 -1.190 Vel = 7.40 7 58.55 1.682 0.0 6.000 46.815 to 120.0 0.0 0.0 0.0 8 7.32 0.0020 0.0 6.000 0.012 Vel = 1.06 8 32.24 1.682 2T 19.799 191.500 46.827 to 120.0 0.0 19.799 0.0 9 39.56 0.0461 0.0 211.299 9.742 Vel = 5.71 0.0 39.56 56.569 K Factor = 5.26 10 -108.04 1.682 21 19.799 39.000 66.196 to 120.0 0.0 19.799 0.0 11 -108.04 -0.2958 0.0 58.799 -17.393 VeI= 15.60 11 57.25 1.682 0.0 16.000 48.803 to 120.0 0.0 0.0 0.0 12 -50.79 -0.0732 0.0 16.000 -1.171 Vel = 7.33 12 56.46 1.682 0.0 6.000 47.632 to 120.0 0.0 0.0 0.0 13 5.67 0.0012 0.0 6.000 0.007 Vel = 0.82 13 32.06 1.682 21 19.799 191.500 47.639 to 120.0 0.0 19.799 0.0 14 37.73 0.0422 0.0 211.299 8.927 Vel = 5.45 0.0 37.73 56.566 K Factor = 5.02 15 -129.95 1.682 2T 19.799 39.000 66.229 to 120.0 0.0 19.799 0.0 16 -129.95 -0.4163 0.0 58.799 -24.476 Vel 18.76 16 52.60 1.682 0.0 16.000 41.753 to 120.0 0.0 0.0 0.0 17 -77.35 -0.1594 0.0 16.000 -2.550 Vel = 11.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 7 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 17 50.89 1.682 0.0 6.000 39.203 to 120.0 0.0 0.0 0.0 18 -26.46 -0.0220 0.0 6.000 -0.132 Vel = 3.82 18 52.89 1.682 0.0 12.000 39.071 to 120.0 0.0 0.0 0.0 19 26.43 0.0219 0.0 12.000 0.263 Vel = 3.82 19 29.14 1.682 2T 19.799 179.500 39.334 to 120.0 0.0 19.799 0.0 20 55.57 0.0865 0.0 199.299 17.232 Vel = 8.02 0.0 55.57 56.566 KFactor= 7.39 21 -122.88 1.682 21 19.799 39.000 66.267 to 123.0 0.0 19.799 0.0 22 -122.88 -0.3753 0.0 58.799 -22.067 Vel = 17.74 .22 56.76 1.682 0.0 16.000 44.200 to 120.0 0.0 0.0 0.0 23 -66.12 -0.1192 0.0 16.000 -1.908 Vel = 9.55 23 55.36 1.682 0.0 8.000 42.292 to 120.0 0.0 0.0 0.0 24 -10.76 -0.0042 0.0 8.000 -0.034 Vel = 1.55 24 30.35 1.682 0.0 12.000 42.258 to 120.0 0.0 0.0 0.0 25 19.59 0.0126 0.0 12.000 0.151 Vel = 2.83 25 30.40 .682 2T 19.799 179.500 42.409 to 120.0 0.0 19.799 0.0 26 49.99 0.0711 0.0 199.299 14.168 Vel = 7.22 0.0 49.99 56.577 K Factor = 6.65 27 -119.77 1.682 2T 19.799 39.000 66.234 to 120.0 0.0 19.799 0.0 28 -119.77 -C.3579 0.0 58.799 -21.047 Vel = 17.29 28 57.38 1.682 . 0.0 16.000 45.187 to 120.0 0.0 0.0 0.0 29 -62.39 -0.1071 0.0 16.000 -1.713 Vel = 9.01 29 56.14 1.682 0.0 17.000 43.474 to 120.0 0.0 0.0 0.0 30 -6.25 -0;.0015 0.0 17.000 -0.026 Vel = 0.90 30 54.57 1.682 21 19.799 177.500 43.448 to 120.0 0.0 19.799 0.0 31 48.32 0.0668 0.0 197.299 13.174 Vel = 6.98 0.0 48.32 56.622 K Factor= 6.42 32 -32.70 1.682 41 39.599 254.000 66.222 to 120.0 0.0 39.599 0.0 33 -32.7 -0.i0324 0.0 293.599 -9.516 Vel = 4.72 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 8 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -32.70 56.706 K Factor = -4.34 34 -32.58 1.682 4T 39.599 254.000 66.214 to 120.0 0.0 39.599 0.0 35 -32.58 -0.0322 0.0 293.599 -9.451 Vel = 4.70 0.0 -32.58 56.763 K Factor = -4.32 36 -32.51 1.682 4T 39.599 254.000 66.210 to 120.0 0.0 39.599 0.0 37 -32.51 -0.0321 0.0 293.599 -9.414 Vel = 4.69 0.0 -32.51 56.796 KFactor= -4.31 38 -33.86 1.682 2E 9.9 222.000 66.201 to 120.0 4T 39.599 49.499 0.0 .39 -33.86 -0.0346 0.0 271.499 -9.389 Vet = 4.89 0.0 -33.86 56.812 K Factor = -4.49 40 -33.85 1.682 2E 9.9 222.000 66.201 to 120.0 41 39.599 49.499 0.0 41 -33.85 -0.0346 0.0 271.499 -9.384 Vet = 4.89 0.0 -33.85 56.817 K Factor= -4.49 6A 29.42 1.049 3E 6.0 23.000 27.593 K Factor = 5.60 to 120.0 0.0 6.000 5.197 6C 29.42 0.2657 0.0 29.000 7.705 Vet = 10.92 0.0 29.42 40.495 K Factor = 4.62 6B 29.99 1.049 2E 4.0 15.000 28.688 K Factor =5.60 to 120.0 T 5.0 9.000 5.197 6C 29.99 0.2754 0.0 24.000 6.610 Vel = 11.13 6C 29.42 1.049 E 2.0 0.700 40.495 to 120.0 T 5.0 7.000 0.0 6 59.41 0.9753 0.0 7.700 7.510 Vet = 22.05 0.0 59.41 48.005 K Factor = 8.57 7A 28.99 1.049 3E 6.0 23.000 26.805 K Factor = 5.60 to 120.0 0.0 6.000 5.197 7C 28.99 0.2587 0.0 29.000 7.501 Vet = 10.76 0.0 28.99 39.503 K Factor = 4.61 7B 29.56 1.049 2E 4.0 15.000 27.870 K Factor =5.60 to 120.0 T 5.0 9.000 5.197 7C 29.56 0.2682 0.0 24.000 6.436 Vet = 10.97 7C 29.00 1.049 E 2.0 0.700 39.503 to 120.0 1 5.0 7.000 0.0 7 58.56 0.9496 0.0 7.700 7.312 Vet = 21.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 9 DNA ELECTRONICS -CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 58.56 46.815 KFactor= 8.56 8A 32.23 1.049 3E 6.0 16.000 33.133 K Factor =5.60 to 120.0 T 5.0 11.000 5.197 8 32.23 0.3147 0.0 27.000 8.497 VeI= 11.96 0.0 32.23 46.827 KFactor= 4.71 hA 28.34 1.049 3E 6.0 23.600 25.611 K Factor =5.60 to 120.0 0.0 6.000 5.197 11C 28.34 3.2480 0.0 29.600 7.340 Vel = 10.52 0.0 28.34 38.148 K Factor = 4.59 11B 28.91 1.049 2E 4.0 15.500 26.648 K Factor = 5.60 to 120.0 T 5.0 9.000 5.197 .11C 28.91 0.2573 0.0 24.500 6.303 VeI= 10.73 hG 28.34 1.049 E 2.0 4.700 38.148 to 120.0 T 5.0 7.000 0.0 11 57.25 0.9107 0.0 11.700 10.655 VeI= 21.25 0.0 57.25 48.803 K Factor = 8.20 12A 27.95 1.049 3E 6.0 23.500 24.918 K Factor =5.60 to 120.0 0.0 6.000 5.197 12C 27.95 0.2418 0.0 29.500 7.133 Vel = 10.38 0.0 27.95 37.248 K Factor = 4.58 12B 28.50 1.049 2E 4.0 15.500 25.909 K Factor =5.60 to 12C.0 T 5.0 9.000 5.197 12C 28.5 0.2507 0.0 24.500 6.142 Vet = 10.58 12C 27.96 1.049 E 2.0 4.700 37.248 to 120.0 T 5.0 7.000 0.0 12 56.46 0.8875 0.0 11.700 10.384 Vet = 20.96 0.0 56.46 47.632 KFactor 8.18 13A 32.06 1.049 3E 6.0 20.000 32.782 K Factor = 5.60 to 120.0 T 5.0 11.000 5.197 13 32.06 0.3116 0.0 31.000 9.660 VeI= 11.90 0.0 32.06 47.639 K Factor= 4.64 16A 26.00 1.049 3E 6.0 28.000 21.556 K Factor = 5.60 to 1200 0.0 6.000 3.898 16C 26.0 0.2114 0.0 34.000 7.189 VeI= 9.65 0.0 26.00 32.643 KFactor= 4.55 16B 26.60 1.049 2E 4.0 19.000 22.568 K Factor =5.60 to 120.3 T 5.0 9.000 3.898 16C 26.6 0.2206 0.0 28.000 6.177 Vet = 9.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 10 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 16C 26.00 1.049 E 2.0 4.700 32.643 to 120.0 T 5.0 7.000 0.0 16 52.6 0.7786 0.0 11.700 9.110 Vel= 19.53 0.0 52.60 41.753 K Factor = 8.14 17A 25.25 1.049 3E 6.0 26.000 20.328 K Factor = 5.60 to 120.0 0.0 6.000 3.898 17C 25.25 0.2002 0.0 32.000 6.408 Vet = 9.37 0.0 25.25 30.634 K Factor = 4.56 17B 25.64 1.049 2E 4.0 19.000 20.966 K Factor= 5.60 to 120.0 T 5.0 9.000 3.898 17C 25.64 0.2061 0.0 28.000 5.770 Vet = 9.52 17C 25.25 1.049 E 2.0 4.700 30.634 to 120.0 T 5.0 7.000 0.0 17 50.89 0.7324 0.0 11.700 8.569 Vel = 18.89 0.0 50.89 39.203 K Factor 8.13 18A 26.54 1.049 3E 6.0 25.000 22.466 K Factor = 5.60 to 120.0 0.0 6.000 3.898 18C 26.54 0.2196 0.0 31.000 6.809 Vel = 9.85 0.0 26.54 33.173 K Factor = 4.61 18B 26.34 1.049 2E 4.0 24.000 22.127 K Factor =5.60 to 120.0 T 5.0 9.000 3.898 18C 26.34 0.2166 0.0 33.000 7.148 Vet = 9.78 18C 26.54 1.049 E 2.0 0.500 33.173 to 120.0 T 5.0 7.000 0.0 18 52.88 C.7864 0.0 7.500 5.898 Vet = 19.63 0.0 52.88 39.071 K Factor = 8.46 19A 29.14 1.049 3E 6.0 21.000 27.080 K Factor =5.60 to 120.0 T 5.0 11.000 3.898 19 29.14 0.2611 0.0 32.000 8.356 Vel= 10.82 0.0 29.14 39.334 KFactor= 4.65 22A 28.11 1.049 3E 6.0 26.500 25.194 K Factor= 5.60 to 120.0 0.0 6.000 3.898 22C 28.11 0.2442 0.0 32.500 7.938 Vet = 10.44 0.0 28.11 37.030 K Factor = 4.62 22B 28.65 1.049 2E 4.0 18.500 26.174 K Factor= 5.60 to 120.0 1 5.0 9.000 3.898 22C 28.65 02530 0.0 27.500 6.958 Vet = 10.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 11 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 22C 28.11 1.049 E 2.0 1.000 37.030 to 120.0 T 5.0 7.000 0.0 22 56.76 0.8962 0.0 8.000 7.170 Vel = 21.07 0.0 56.76 44.200 K Factor = 8.54 23A 27.42 1.049 3E 6.0 26.500 23.967 K Factor = 5.60 to 120.0 0.0 6.000 3.898 23C 27.42 0.2332 0.0 32.500 7.580 Vet = 10.18 0.0 27.42 35.445 KFactor= 4.61 23B 27.95 1.049 2E 4.0 18.500 24.902 K Factor = 5.60 to 120.0 T 5.0 9.000 3.898 23C 27.95 0.2416 0.0 27.500 6.645 Vel = 10.38 23C 27.41 1.049 E 2.0 1.000 35.445 to 120.0 T 5.0 7.000 0.0 23 55.36 0.8559 0.0 8.000 6.847 Vet = 20.55 0.0 - 55.36 42.292 K Factor = 8.51 24A 30.34 1.049 3E 6.0 21.000 29.357 K Factor = 5.60 to 120.0 T 5.0 11.000 3.898 24 30.34 0.2813 0.0 32.000 9.003 Vel= 11.26 0.0 30.34 42.258 K Factor = 4.67 25A 30.40 1.049 3E 6.0 21.000 29.475 K Factor = 5.60 to 120.0 T 5.0 11.000 3.898 25 30.4 0.2824 0.0 32.000 9.036 Vel = 11.29 0.0 30.40 42.409 K Factor = 4.67 28A 28.42 1.049 3E 6.0 27.000 25.750 K Factor =5.60 to 120.0 0.0 6.000 3.898 28C 28.42 0.2492 0.0 33.000 8.224 Vel = 10.55 0.0 28.42 37.872 K Factor = 4.62 28B 28.96 1.049 2E 4.0 19.000 26.746 K Factor = 5.60 to 120.0 T 5.0 9.000 3.898 28C 28.96 0.2581 0.0 28.000 7.228 Vet = 10.75 28C 28.42 1.049 E 2.0 1.000 37.872 to 120.0 T 5.0 7.000 0.0 28 57.38 0.9144 0.0 8.000 7.315 Vel = 21.30 0.0 57.38 45.187 KFactor= 8.54 29A 27.80 1.049 3E 6.0 27.000 24.650 K Factor = 5.60 to 120.0 0.0 6.000 3.898 29C 27.8 0.2394 0.0 33.000 7.899 Vel = 10.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 12 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0• 27.80 36.447 K Factor = 4.60 29B 28.34 1.049 2E 4.0 19.000 25.607 K Factor =5.60 to 120.0 T 5.0 9.000 3.898 29C 28.34 0.2479 0.0 28.000 6.942 Vel = 10.52 29C 27.80 1.049 E 2.0 1.000 36.447 to 120.0 T 5.0 7.000 0.0 29 56.14 0.8784 0.0 8.000 7.027 Vel = 20.84 0.0 56.14 43.474 K Factor = 8.51 30A 26.89 1.049 3E 6.0 29.000 23.050 K Factor = 5.60 to 120.0 T 5.0 11.000 3.898 30C 26.89 0.2250 0.0 40.000 8.998 Vel = 9.98 0.0 26.89 35.946 K Factor = 4.49 30B 27.69 1.049 3E 6.0 21.000 24.447 K Factor = 5.60 to 120.0 1 5.0 11.000 3.898 -30C 27.69 0.2375 0.0 32.000 7.601 Vel = 10.28 30C 26.88 -.049 T 5.0 4.000 35.946 to 120.0 0.0 5.000 0.0 30 54.57 0.8336 0.0 9.000 7.502 Vel = 20.26 0.0 54.57 43.448 K Factor = 8.28 1 32.84 6.357 0.0 12.000 66.180 to 12C.0 0.0 0.0 0.0 3 32.84 0.0 0.0 12.000 0.0 Vel = 0.33 3 32.84 6.357 0.0 12.000 66.180 to 120.0 0.0 0.0 0.0 5 65.68 0.0002 0.0 12.000 0.002 Vel = 0.66 5 110.65 6.357 0.0 12.000 66.182 to 1201.0 0.0 0.0 0.0 10 176.33 0.0012 0.0 12.000 0.014 Vel = 1.78 10 108.03 6.357 0.0 12.000 66.196 to 120.0 0.0 0.0 0.0 15 284.36 0.0028 0.0 12.000 0.033 Vel = 2.87 15 129.95 6 357 T 37.72 7.000 66.229 to 120.0 0.0 37.720 0.0 50 414.31 0.0055 0.0 44.720 0.245 Vel = 4.19 50 -822.45 6.357 T 37.72 1.000 66.474 to 120.0 0.0 37.720 0.0 21 -408.14 -0.0053 0.0 38.720 -0.207 Vel = 4.13 21 122.88 6.357 0.0 12.000 66.267 to 120.0 0.0 0.0 0.0 27 -285.26 -0.0028 0.0 12.000 -0.033 Vel = 2.88 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 13 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 27 119.77 6.357 0.0 12.000 66.234 to, 120.0 0.0 0.0 0.0 32 -165.49 -0.0010 0.0 12.000 -0.012 Vel= 1.67 32 32.69 6.357 0.0 12.000 66.222 to 120.0 0.0 0.0 0.0 34 -132.8 -0.0007 0.0 12.000 -0.008 Vet = 1.34 34 32.58 6.357 0.0 12.000 66.214 to 120.0 0.0 0.0 0.0 36 -100.22 -0.0003 0.0 12.000 -0.004 Vet = 1.01 36 32.51 6.357 0.0 43.000 66.210 to 120.0 0.0 0.0 0.0 38 -67.71 -0.0002 0.0 43.000 -0.009 Vet = 0.68 38 33.86 6.357 0.0 12.000 66.201 to 120.0 0.0 0.0 0.0 40 -33.85 0.0 0.0 12.000 0.0 Vet = 0.34 0.0 -33.85 66.201 K Factor= -4.16 -2 -32.84 4.26 0.0 12.000 56.588 to 120.0 0.0 0.0 0.0 4 -32.84 -0.0003 0.0 12.000 -0.004 Vet = 0.74 4 -32.84 4.26 0.0 12.000 56.584 to 120.0 0.0 0.0 0.0 9 -65.68 -0.0012 0.0 12.000 -0.015 Vet = 1.48 9 39.56 4.26 0.0 12.000 56.569 to 120.0 0.0 0.0 0.0 14 -26.12 -0.0002 0.0 12.000 -0.003 Vel = 0.59 14 37.73 4.26 0.0 12.000 56.566 to 120.0 0.0 0.0 0.0 20 11.61 0.0 0.0 12.000 0.0 Vet = 0.26 20 55.57 4.26 0.0 8.000 56.566 to 120.0 0.0 0.0 0.0 26 67.18 0.0014 0.0 8.000 0.011 Vet = 1.51 26 49.99 4.26 0.0 12.000 56.577 to 120.0 0.0 0.0 0.0 31 117.17 0.0038 0.0 12.000 0.045 Vet = 2.64 31 48.32 4.26 0.0 12.000 56.622 to 120.0 0.0 0.0 0.0 33 165.49 0.0070 0.0 12.000 0.084 Vet = 3.73 33 -32.69 4.26 0.0 12.000 56.706 to 120.0 0.0 0.0 0.0 35 132.8 0.0048 0.0 12.000 0.057 Vet = 2.99 35 -32.58 4.26 0.0 12.000 56.763 to 120.0 0.0 0.0 0.0 37 100.22 0.0028 0.0 12.000 0.033 Vet = 2.26 Computer Programs by Hydratec inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams ADVANCE FIRE PROTECTION Page 14 DNA ELECTRONICS - CLEAN ROOM Date AUGUST 2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Ce' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 37 -32.51 4.26 0.0 12.000 56.796 to 120.0 0.0 0.0 0.0 39 67.71 0.0013 0.0 12.000 0.016 Vel = 1.52 39 -33.86 4.26 0.0 12.000 56.812 to 120.0 0.0 0.0 0.0 41 33.85 0.0004 0.0 12.000 0.005 Vel = 0.76 0.0 33.85 56.817 K Factor= 4.49 50 822.45 6.357 E 17.603 22.000 66.474 to 120.0 0.0 17.603 0.0 TR 822.45 0.0195 0.0 39.603 0.772 Vel = 8.31 TR 0.0 6.357 0.0 26.000 67.246 to 120.0 0.0 0.0 0.0 BR 822.45 0.0195 0.0 26.000 0.506 Vel = 8.31 BR 0.0 8.27 E 28.468 83.000 67.752 to 140.0 T 55.354 90.148 0.0 OH 822.45 0.0041 G 6.326 173.148 0.705 Vel = 4.91 OH 250.00 7.68 E 22.555 175.000 68.457 Qa=250 to 150.0 0.0 22.555 0.0 DCA 1072.45 0.0084 0.0 197.555 1.658 Vel = 7.43 DCA 0.0 8.27 E 28.468 6.000 70.115 to 140.0 Zfc 0.0 28.468 4.282 * * Fixed Loss = 4.282 DCB 1072.45 0.0066 0.0 34.468 0.228 Vel = 6.41 DCB 0.0 7.68 T 43.857 65.000 74.625 to 150.0 G 5.012 48.869 2.166 CM 1072.45 0.0084 0.0 113.869 0.955 Vel = 7.43 0.0 1072.45 77.746 K Factor = 121.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ç CA CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: DNA Electronics SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 1891. Rutherford Road CITY: Carlsbad PHONE: ( 714)526-2231. (Advance Fire Protection) FAX NUMBER: (562) 691-5482 Largest Building (ft.2): Sprinkled? Construction Type:_________________ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): northeast end of cul-de-sac Rutherford Road TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 126 PSI Hydrant Number (if applicable):H61303 Elevation of test 260 (est) Feet Date/Time of T ct1 Ftot Tube ding PSI Corresponding Flow GM Total Flow: 2,000 GPM Residual Pressure 115 PSI At peak demand , this water system is capable of providing a fire flow discharge of 3,900 gpm at the maximum velocity of 15 fps. At 20 psi, the velocity in this area would exceed 15 fps and is not recommended per criteria. 'Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: I have witnessed and/or reviewed this water flow information and by personal knowledge and/or on-site observation certify that the above information is correct. Name: Jennifer R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:__________________________________________ Title/Org: P9 _ctManager Date: 07/19/2016 1891 Rutherford Road Fire Request _\,,_'•_ ... ) 'S , / — I,, . /1 H6i33-............. la-......... / / i• /• ' N / / •"p- / / // N p-'- / U • 10 /// / • /' : • / U _____ U/i - -'--- - Cb // S / N - 18 __/ -----•----, 18 ----------- - .,------------4-- - — N, I Prepared By: Jennifer R. Mael, P.E. - MCS Date: Tuesday, July 19, 2016 F~= 100 200 300 400 500 GPM 7.5 15 (FPS) 6.3 12.6 18.9 25.2 31.5 LIPS :14" 103.5 15 Description The FEBCO MasterSeries® Model 856 69.0 10 double check detector in-line configuration cc CD has low head loss and is used in non-health hazard (non-toxic) connections including: fire sprinkler and standpipe systems requiring detection of unauthorized water use. Features Easy to service Low head loss Shorter and lighter than traditional designs Fusion epoxy coated Protects against back pressure and back siphonage Maximum working pressure of 175 PSI (1200 Kpa) Temperature range of 32°F to 140°F (0°C to 60°C) See page 50 for listing of approvals Materials Main Valve Body: Ductile iron Coating: Fusion epoxy coated internal and external Trim: Bronze Elastomer Discs: EPDM Springs: Stainless steel Shut-Offs: OS&Y Gate Valves Bypass Valve Body: Bronze Bypass Elastomers: Nitrile lIr,QQ Q rin as Qt&r,Ic,. Q#c,I .t --------_ ------—_ ----_ I_ -- — - ---- -- — _ ------=_. L — ---- — _ SI_I 0 OL 0 0 KPa PSI 103.5 15 r 69.0 10 34.5 5 00 750 GPM ] (FPS) 47.3 IFS 3" 0 0I 0 KPa PSI 103.5 15 69.0 11) ca 34.5 5 00 '7 P"." V' • I%J. S.1LCIfl UOO KPa PSI 206.9 30 Options ° UL/FM OS&Y RW Gate Valves 0137.9 20 o Less Gates Left-Hand Bypass 69.0 10 00 0 1000 2000 7.5 0 63.1 126.2 A - Vertical Up Orientation B - Horizontal Orientation 118 1 FEBCO is a product of CMB Industries, Inc. I www.FEBCOonline.com 3000 4000 5000 GPM 15 20 (FPS) 189.2 252.3 315.4 LPS 300 600 900 1200 1500 GPM