Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FA160030; Permit10/10/24, 11:39 AM FA160030 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA160030 Status: ISSUED Applied 6/2/2016 Approved: 6/8/2016 Issued: 6/8/2016 Inspector: 2180 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2120702500 Lot #: 0 Reference No.: PC #: Project Title: CALLAWAY HQ FITNESS CTR SHOWER TI TO EXISTING FITNESS CENTER RESTROOMS. REMOVE EXISTING STROBES AND INSTALL 2 NEW SGTROBES AND 2 NEW HORN STROBES AS SHOWN ON PLANS IN EXISTING SPRINKLERED BLDG. REWORK EXISTING NAC CIRCUIT 3-2 ON EXISTING FACP ALL OTHER EXISTING DEVICES TO REMAIN AS IS. SYSTEM IS MONITORED BY CENTRAL STATION. Applicant: NOVA SECURITY SUITE 103 8779 COTTONWOOD AV SANTEE, CA 619-448-3007 Owner: CALLAWAY GOLF CO 2180 RUTHERFORD RD CARLSBAD CA Fees Md'I Fees (j) t ($) Balance 317 0 317 about:blank 1/1 - Callaway Golf HQ Bldg - Fitness Center Restroom T.I. 2180 Rutherford Road Carlsbad, CA. 92008 Fire Alarm Submittal Restroom Remodel T.I. 5-31-16 Submitted By; *VA SECURITY 8779 Cottonwood Ave. Suite 103 Santee, CA. 92071 619-448-3007 Cont. Lic. C-°"" - FA1 60030 2180 RUTHERFORD RD Callaway Golf HQ Bldg - Fitness Center Restroom T.I. Fire Alarm Submittal Equipment List Model Manufacture 5820XL SILENT KNIGHT RSSWP-24MCCH WHEELLOCK ASWP-2475C WHEELLOCK Description Existing FACP Weather Proof Strobe Weather Proof Horn/Strobe CSFM# 7165-0559:135 7300-0785:154 7125-0785:131 0 SILENT KNIGHT IntelliKnight® Model 5820XL Addressable Fire by Honeywell Alarm CoAtrol System The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD and SK SLC devices on a FACR lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The lntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows® based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:135; MEA 429-92-E Vol. VI; FM Approved lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel InteIIiKnight 5820XL Wnws Based Fadity Addressable Fire Alarm System Management Software SK (System Sensor) Protocol Devices Wndaws Bused Up/Download Software Ljl ¶j2o:L € T. 8Flexput 1/OCocuita C! can be inputs or outputs if 1 1:. Remote Annuncmor 5824 R'cta.Ccvmm 14dure 1! I!!O 8 Fbeput' I/O Circuits can be Inputs III oroulputs II CrI.3mte,. Ion. ,erLuC, f (4) caL ;i4 SK.Ion SK.fttnittoc Skiso SK-Control-6 BK.corlrol 5200SR St(AcdiInnte Si(.Zone Ad4mtX!o Adj3eetln Faj!tlsoittx ACeEeable CISc Me1 Soun.r Mut-ortere Z.. WOW;luri,-q.i:iWOW;Mt'Uu!9 rtcuricu ,! Gisu tor, Cr;it colitIs hileluce Cauct IV dg. mottle tdul5 wtectcr 1190 8K-PR000 SKMontor-2 SKRdeymon-2 c-I1ea1 8224R 022401 B2101 1l-Photo-T CeuMonter SKlleut-ROR Ruby ssrm M=ule Ocoldomitcr SK-Heal-MT Owe loll ttlOtCtIOflC Adaeenat4e Cetnctm lout .emto,c !.otot l/mIjc. I I i I I ffwm OK-Besen SK-Pbn-10 SK-etitl-OA SK.OIt $KMrthnon Stc.Relay-8 SK.Zone (-Rdav SK-Seam-T 'ccutnt rAomrstomeor A/settle BK-Pull-BA Ajswoetlu 1" "61" li.0000 D.m Module Aol S4morl Dlm.!ie Mtr!nr Recollect Mtmuotl0 AdISoteetl, Me/dc Mc/ulc iwerf3ce RMy MiCe b/eddIe * WJk 1 J 5865-4or5865.3 LEDAmLnclay i Use the 5880 to control up 104 - L 5883 Relay Interface Modules -232 Compatible CS Receiver Automat/on P;— Software Internet SK.2/2UD Connection VisocAlarm P Communicator R&ays lnte!!iKnight Mode! 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A © 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA © 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5'W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2"W x 264"H x 4.2"D (40.6Wx67Hx 11.8Dcm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ3IX (two required) S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the !ntelliKnight system. 5820XL supports three 5815XLs. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505-DTS-K Remote test switch. Used with SD505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 5K Devices Data Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our Made In America product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203) 484-7161, Fax: (203) 484-7118. www.slientknight.com. © 2012 Honeywell International Inc. lntelliknight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURiTY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000 : Control Units 058200P : Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor tntelliknight 5820: Enclosure 5860/5860R1RA-1000: Annunciator 5496: Power Module 5824 : Serial/Parallel Interface 5895/5895XL/RPS-1000 : Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM : Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM : Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June30; 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories L;?FJ E:* Description: Designed for life safety, performance and reliability, Cooper Notification's Wheelock cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-I2WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-35°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper Notification provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. D OU L !~~- X <@> M'EA APPROVED E5946 151-92-E 7125-0785:131 (ASWP) 85391 7125-0785:146 (E170WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM), Chicago (BFP) and ULC. See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal The series RSSWP, ASWP, AH-24WP, MTWP-2475W, and MT-1 2/24 have ULI ULC approval down to -4UF. The ET-1010 and ET70WP have UL approval down to-40'F. The AH-I2WP has UL approval down to -31 °F. Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-12/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max Current AH 24VDC I2VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 JL Reverberant dBA © 10 Feet Wafts 1/8 1/4 1/2 1 2 1 4 1 8 ET-1 010 77 180 1 83J 86 1 87 92 194 ET70WP 78 1 81 1 84 187 1901931 95 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - RSSWP-24MCWH X - X - - RSSWP-24MCCH X - X - - Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X - X - - ASWP-MCCH X - X - - Multitone Strobe MTWP-2475 X X X X - MTWP-MCWH X - X - - MT\NP-MCCH X - X - - Horns/Audibles AH-24WP X X X X X AH-12WP X X X X X T-12/24 X X X X I X Speaker Strobe T70WP-2475 X - X X - T70WP-185 X - X X - T70WP-177 X - X X - T70WP-115 X - X X - ET70WP-135 X - X X - NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT, VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount _ _I0RSSWP MflNP RSSWP MTWP MT AH ASWP ASWP ET70WP ET-1010 Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR_Red 5167 RSSWP-24MCWH-FW White 5165 LRSSWP-24MCCH-FWWhi Audible Strobe Audible Strobe ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 ASWP-24MCWH-FR Red 5137 SWP-2475C:? hi ASWP-24MCWH-FW White 5140 ASWI4MC60R Red 5149 Multi-tone Strobe ASWP-24MCCH-FW White 5157 MTWP-2475W-FR Red 8420 Multi-tone Strobe MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 Speaker Strobe MTWP-24MCCH-FW White 5122 ET70WP-2475W-FR Red 9077 Speaker Strobe ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70-24 185W-FR Red 4885 ET70WP-2475C-FW White 4454 ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24135W-FR Red 4872 ET70WP-24177C-FW White 4859 ET70WP-24135W-FW White 4875 ET70WP-2411 SC-FR Red 4550 ET70WP-24115C-RN White 4732 Candela Ratings Series UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F RSS, ET70WP and MT INP UL Max Current (Strobe Only) ASWP High Med Low 2475W 30° 180 115 0.138 0.168 0.155 0.150 2475C g 180 115 0.138 0.168 0.155 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 47 EO3TO 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 JL Max. Current (Audible) MTWP/MT 24 VOC MT 12 VOC IBA HI STD HI 510 Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Mounting Accessories WFP WFPA lOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Mounting Options: _______________________________________ Flush Plates Backboxes, Plates, Gasket Kits WFPA-R Red 4698 Surface Mount Flush WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 WFP-W White 4697 RSSWP Strobes WPSBB WPSBB + WP-KIT WFP Backboxes ET70WP Speaker Strobes lOB lOB + WP-KIT WFP IOBR* Red 5046 ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA lOBW* White 5047 WPSBBR* Red 9751 AHWP Horns WBB - WFP WPSBBW* White 3033 ET-1010 Speakers WBB - WFP WPBBR* Red 9014 WPBBW* White 4692 MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP WBB-R Red 2959 Multitone Horn lOB lOB + WP-KIT I WFP WBB-W White 2960 lOB, WPSBB and WPBB models include weep holes and plug in the event that moisture may have entered the appliance Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROM + _____ ______ + TO NEXT PRECEDING RED APPLIANCE APPLIANCE - OR EOLR OR FACP BLACK STROBE AUDIBLE SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12124 APPLIANCES FROM PRECEDING TO NEXT APPLIANCE + tt] I APPLIANCE OR OR EOLR - FACP SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWP Sync Strobe 0 Circuit Module P or ower 0 Audible } Circuit LIII ote Supply to FACP NAC#2 0 Strobe circuit requires constant voltage. Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc. dba Cooper Notification standard terms and conditions. S9004 WP 11/12 Notification Wheelock' NUM) ARCI4ITECTS AND ENGINEERS SPECIFICATIONS Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-11 010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. I1!EAt4 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0785:0154 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models RSSWP-2475W and RSSWP-2475C synchronous or non-synchronous strobe light. Model may be followed by two alpha or numeric characters indicating lettering and color, followed by W for wall mount or C for ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. Models RSSWP-24MCWH (wall mount) & RSSWP-24MCCH (ceiling mount) audible/strobes for the- hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. RATING: Electrical: 16-33 VDCNFWR Flash rate: 60 flashes/mm. Candela: RSSWP-2475W 30cd (115cd at-40 C) RSSWP-2475C 30cd (115cd at40 C) RSSWP-24MCWH Selectable 135/185cd (65/90cd at-40 C) RSSWP-24MCCH Selectable 115/177cd (50/75cd at-40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model can be used outdoors when used with WPSBB back box only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a strobe light for use with separately listed electrically compatible fire alarm control units. For indoor or outdoor use. Intended for wall mount or ceiling mount. Lens color may be white, red, blue, green or amber. For synchronized strobes, Models SM-12/24, SMX-12/24 Sync Modules, DSM-12/24 or DSMX-12/24 Duel Sync Modules (CSFM Listing No. 7300-0785:1323) or power supply PS-12/24-8 (CSFM Listing No. 7315-0785:149) must be used. NOTE: *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0131 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustnes.com DESIGN: Models AS-1215, -2415, -1230,-2430,-121575,-241575,-2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *ASWP 2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *Aswp24McwH and *ASWP..24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 Page 2 of 2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd,1575:15/75cd,30:30cd,75:75cd,95:95cd,100: 100cd,1 10:ll0cd MCW: Selectable l5cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at 40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at 40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-I2WP, AH-24WP, *ASwp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 øi This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division