HomeMy WebLinkAbout2231 RUTHERFORD RD; 110; FPC2020-0153; PermitPERMIT REPORT C CL7city of arlsbad Print Date: 11/12/2020 Permit No: FPC2020-0153 Job Address: 2231 RUTHERFORD RD, # 110. CARLSBAD, CA 92008-8820 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120701900 Track #: Applied: 08/31/2020 Valuation: $581,037.00 Lot #: Issued: 09/16/2020 Occupancy Group: Project #: Finaled Close Out: 11/12/2020 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: IMPLUS (CARLSBAD COURTYARD) -SPRINKLER MONITORING TI Applicant: FPContractor: JMG SECURITY SYSTEMS JMG SECURITY SYSTEMS TREVOR ASHFORD 17150 NEWHOPE ST, # 109 17150 NEWHOPE ST, U 109 FOUNTAIN VALLEY, CA 92708-4273 FOUNTAIN VALLEY, CA 92708-4250 (714) 545-8862 (714) 943-6156 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $136.00 Total Fees: $136.00 Total Payments To Date: $136.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov [HIGHLIGHTED SEll UL & FM Certificates of Compliance Cut Sheets and CSFM listings: CARLSBAD COURTYARD IMPLUS 2231 RUTHERFORD ROAD CARLSBAD, CA 92008 REVISION 1 TENANT IMPROVEMENT ADDITIONS Installation Company: "J KISECURITY UIVIU SYSTEMS Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 (714) 545-8882 U Applicant ID No: 25705701 Service Center No: I Expires: 31-MAR-2021 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service Company: (257057-001) Service Center: (257057-0011 ADVANCED PROTECTION INDUSTRIES LLC, ADVANCED PROTECTION INDUSTRIES LLC, DBA NATIONAL MONITORING CENTER DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR 25341 COMMERCENTRE DR LAKE FOREST CA 92630 LAKE FOREST CA 92630 The Alarm Service Company is Listed In the following Certificate Service Categories: File-Vol No. CCN Listing Category S81261 UUFX 7 [Signal and Fire Alarm Equipment and Services] (Protective Signaling 1 Services) Central Station / / I / / I I :1 ii 1 t ' \ \ / / THIS CERTIFICATE EXPIRES ON 31MAR2021*** / "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" tXR]50F(JXR550F( FAR FEATURES Up to 562 two wire smoke Eight communication paths Built-in 32 character LED detector or fire initiating between the panel and annunciator on panel door zones on XR550FC central station Output groups deliver cup to 142 two wire smok Built-in remote or maximum functionality ?detector or fire initiating) on site firmware with easy programming (zones on XP150FC upgrade capability Onboard Network jip to 5 Amp 12 VD C I 12,000 event buffer Onboard 10/100 (smoke and auxiliary output I autosensing Ethernet or (with OVC protection) - French Spanish and English Wi Fi connection menus available ( Upto 7Amps12VDO Customizable check in time (supervised bell outpu6 Multiple onboard status LEDs and retry time Up to 506 fully Up to 100 output schedules Suitable for multi site programmable Form C relays to control relays and panel applications outputs ' Serial 3 Digital Dialer orCID reporting to multiple receivers 32 individual reporting areas with common areas DMP.COM 0 0 0 0 0 0 @DMPALARMS XR150FC AND XR550FC FIRE PANELS The XR15ODFC and XR550DFC provide basic fire monitoring for any single site application. The XR150DNFC and XR55ODNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC, enhanced by the onboard Ethernet connection that allows the use of Network Monitoring. Both panels come fully assembled from the factory with the following components: Control Panel The XR150FC and XR550FC Series addressable fire panelsprovide complete system control for local NAC operation. Additionally, DAd, NET, or Cell communication to the central station are provided. The microprocessor-based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. - Keypad Annunciator The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy to use. Transformer and Enclosure The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PlC for power circuit protection. FLEXIBLE COMMUNICATION The XR150/XR550 Series of commercial fire panels has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and central station. The unique DMP Serial 3 format supports 16 or 32-character users, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. REMOTE ANNUNCIATOR Install up to eight 630F remote annunciators to meet the requirements of virtually any installation. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series panels may be used with the 263 Series Cellular Communicators as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263 communicator provides the security of a communication link that continues to function, even when landlines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works over a variety of carriers in the USA and Canada. EIGHT COMMUNICATION PATHS Configure up to eight communication paths between the panel and central station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the central station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and e-mail status from the keypad. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignal, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR150FC and XR550FC provide up to 574 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on board and four on the 715 Module, plus eight panel burglary zones. Up to 64 zones are available on 16 keypad addresses, and up to 100 zones are available on each built-in LX-Bus using expansion modules. FIRE VERIFY This is used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR550FC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The One-Man Walk test allows a single technician to check the panel response to fire, burglary, panic, and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX- Bus for missing, overlapping and/or extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATABLE The XR150FC and XR550FC panels accept software updates using Remote Link—software. This makes it easy to perform the flash update remotely any time new panel feature updates release. FIRE PANELS OUTPUTS The XR150FC and X550FC allow the use of two SPDT relay outputs and four open collector outputs, which may be activated by zone or system events, by schedule, through the User Menu, or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched-ground outputs. STATUS LIST To provide maximum system flexibility, fire zones may be p'ogrammed to display at a specific: keypad. In this manner, all fire zones can be monitored in one location, and other zones can be programmed to display and be monitored at different keypad locations. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® Windows®. The XR150FC and XR550FC panels include an interface connection for installers to use to connect a laptop computer. COMMERCIAL WIRELESS FIRE DEVICES The list of DMP wireless devices that have earned the UL Commercial Fire Listing include: 1103 Universal Transmitter: Two-input transmitter typically used in commercial burglary door or window applications. 1100R Wireless Repeater: Extends the communication range of DMP receivers, enabling physically larger, more reliable wireless security systems. 1100X Wireless Receiver: The 1100X Receiver supports up to 500 transmitters and satisfies all wireless applications. 1100XH High Power Wireless Receiver: Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments. Commercial Smoke Detectors: The 1164 includes synchronized sounders, and a tamper switch. The 1164NS is for applications with existing sounder/ notification devices. 1183 Wireless Heat Detector: The 1183 Series is a reliable, ceiling-mount heat sensor available in two versions. The 1183-135F responds if the temperature exceeds 135°. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more. 1184 Carbon Monoxide Detector: The 1184 Carbon Monoxide Detector is the ideal choice for difficult-to- wire locations, applications where room aesthetics are critical, or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper, and low-battery messages to the panel. L 7. Mini-Horri Motor Bell th' Strobe Horn Strobe t 4 Sync Module Sync Module 7.!.\ 1183-135R 1103-W 1164-W Wireless Rate of Rise Universal Transmitter Commercial Listed Smoke Detector Heat Detector . with Sychronized Sounder I PULL \ 5SSsS. t Li I 1103-W 850S Universal Transmitter Manual Fire Alarm I Pull Station i184-W Wireless Carbon F11100R-W Monoxide Detector 1100XH-W 630F Remote Annunicator 711 715-8 or 715-16 Zone Expansion Module Zone Expansion Module FIRE PANELS Keypads ___ (LCD Remote Fire Command) Expansion Modules 710 Bus Splitter/Repeater (Single Zone Expgjo 114 4-zone Class Expansion 114-8 8-zone Class-B Expansion 114-16 16-zone Class-B Expansion 115 4-zone 2-wire Smoke Expansion 715-8 8-zone 2-wire Smoke Expansion 715-16 16-zone 2-wire Smoke Expansion 716 Output Expansion, 4 Form C relays, 4 Open Collector Outputs 717 Graphic Annunciator: 20 Open Collector Outputs Cellular Communicators 263( COMA Cellular Communicator 263H HSPA Cellular Communicator 263HCAN HSPA+ Cellular Communicator Canada (263lIE-\IEV (LIE Communicator for Verizon 263LTE-A LIE AT&T ming Soon Auxiliary Modules 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A 'Dual Phone Line Module Power Supplies 505-12/LX 5 Amps @12 VDC 505-121 5 Amps @12 VDC 505-12A 5 Amps @12 VDC Pull Stations 850 Series Pull Stations Smoke/Heat Detectors 2W-BLX Conventional Smoke 2W1-BLX Conventional Smoke/Heat Accessories 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push Button 305 Plug-in Output Relay 306 Tamper Harness 301-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 lightning Suppressor 374 Surge Voltage Suppressor 381-2 18' Coax Extension 431 Output Harness 861 Power Distribution Module Central Station Receivers SCS-1R Network Enabled Receiver compatible with central station receivers that accept Standard (ID, DD, or DMP Serial 3 messaging SCS-VR Virtual Receiver Software only solution that runs on a server for network IP and cellular communications DMP Wireless 1100X Receiver 1100XH High-Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1164 Wireless Smoke Detector with Synchronized Sounder 1164N5-W Wireless Smoke Detector with No Sounder 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector Computer Software Remote Link Programming Software Dealer Admin System Specifications Primary Power (included) 16 VAC 56 VA Iran former Secondary Power: .. 12 VDC Battery Models: 365, 366, 368 or 369 Output Rating: Bell Up to .7 rrips at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For installations, total be/f, smoke, and auxiliary cannot exceed 12 Amps using a 56 VA transformer. Current Draw: l8OmA Enclosure: Material Cold-rolled steel (Red) Ordering Information 1XR150DFC-R XR150 Fire Control Panel XR15ODNFC-R XR150 Fire Control Panel with Nntwnrk XR55ODFC-R XPIY3 Fire Control Panel 'ODNF(-R XR550 Fire Control Panel with Network Listings and Approvals California State Fire Marshal ( Pl1 New York FDNY Refer to the XR150FC/XR550F Li si pt oce Guide (11-1330) and specific rpliance listings for installation and pr r tmming requirements necessary to meet a particular approval. FCC Pa FCC Pa rt 15 Underwriters Laboratori (UL) Li led ANSI/UL 864 Fire Protective Signaling For additional information, go to DMP.com/Compliance. 800.641 4282 I DMP.com 2580 N. Partnership Bind, Springtieid, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global comp on 01 2018 Digital Monitoring Prod do, Fr. 1 11 I I 1 11 suitable for Class B (as applicable for the Initiating and signaling line circuits per ANSI/UL 864 Table 48.2 or 48.3). tie Zone Installation limes under 9 10 local Authority Having Jurisdiction (A/O). Using verification delays on zones 9 and 10 is optional. Use the delays marked on the Ohm Ohm smoke detectors or Resistor Resistor the smoke detector = Supervised Circuit installation wiring diagram. IVerification IConEjol Uniti Smoke I Detector I Zones I Delay I Model I Delay 13.6 sec. I_sec I Zone Expander Model 715 7)1 7mA © 12 VDC Models 715-8, 715-16 OmA © 12 VDC one Expander p to 8 Zones) Model 712-8 2 19mA © 12 VDC - - Ell System Components 31 Wiring Diagram The diagram shows some of the accessory modules you can connect for use in various applications. A brief description of each module follows in section 3.4. a FeAt Emu st be nconduitaed out the bet side of the oncosure. exit right arid maintain 1/4" separation I I LED 0 5r4r0 CO/ar Coda-Model 431 Harfiwi Wiring on terminals S through 22 must I I power Form C Relay. P2) Activity LED Link LED OuuO 2 N/s Orangnp/khltn JI from the AC and battery posatve wiring. 1 I o,rwo 2 Corn Wilte/COoy ET1IERNEF Ou/Put 2 N/C k101nt/Wlrlto Front NSVA 1118175VA Output L N/u 0run9e PHONE LINE 00/POt 1 Cxv Gray Output 1 N/C CO/Ot Rea Lp AnnoinolatOr Oiitpoito (211) 00/Put CO/or Code Ta XR55OFC Series Panel 0050013 Rod Output 4 voiiow no/Puts Green no/Putt eliok 318 (333 LOAD • • Heat detectors, pull stations, or any other contact devices listed PUT 1)2 2 316 • [i]] for Fire protective Signaling can be O3-6 fl 324 connected to zones 113 310 Lncj [Ir RESET 36 9 and 10. Zones 9 and 10 and BatteryClD Start ..00)4 XBUS LX CELL MODULE Model 715 compatibility TAMPER Identifier: A 38 314 39 315 317 P g~~ 319 Maximum operating runge:9.8 VDC to F1 ROG FIF]• 14.0 VDC. Class B (Style A). 11 18 Z9+Z9-Z10+Z10- NFPA 72 This equipment should be installed in accordance with Chapter 11 of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenance, evacuation planning, and repair service in to be provided with this equipment. All circuits are inherent Power Limited except the red battery wire and AC terminal. DMP Transformer 16 VAC 56 VA Clans 2 Wire-in. Secondary Power Supply 1.0 Amps Max. charging current. Use only 12 VDC rechargeable batteries. DMP Models 364, 365, 366, 368, or 369. Replace batteries every 3 to 5 yearn. Bell 12 VDC nominal Minimum cutoff time is 5 minutes. .7 Amp Max Keypads Model 630F 60mA at 8 to 14.5 VDC (3 8 (3888 _ 010101 EEE .8 .8 PU 0 0 5 saGa 6 Gaul 1k V 1 1k 1 C - 01010101 C r`1 C rod rod 0/not Or. Ohm 0/tm tamo 01w 01w 0/ Listed Resistors 1.0k Ohm - DMP Model 311 -edIt r`1 3.3k Ohm - DMP Model 309 lv n n Ohm - DMP Model 308 d Cold Water Pipe t Earth 10K Ground Ink'' aa to U Auxiliary Power Bell Total current combined from Bell ojtelf time at terminals 1, 11, 25, 27, and - LX500-LX900 range i55to99 minutes marchtime RED .5 Amp Max and non-coded. - RED YELLOW t GREEN I BLACK fifi DD tth mImi DCOe-lE3 I Zone Expander I I Zone I I I Model 714 I Expander I I I 7mA© 12 VDC I I Model 711 I I( Smoke Models 714-8, 714-16 I I 7mA © 12 I I Detector \ 20mA © 12 VDC I VDC I Use UL Listed Power SupervIsIon Relay I I U U lkOhm 1k Ohm lkolurr 1k 0/nfl 1k rated at 12 VDC. 1o_) WARNING 1k 0/fin THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION FEATURE THAT RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS WARNING: Incorrect SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER connections may cause SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS damage to the unit. APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION (ANJ). CAUTION: DO NOT USE LOOPED WIRE [] UNDER TERMINALS. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. Figure 1: XR1 50FC/XR550FC Series Wiring Diagram 3.2 Lightning Protection Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on XR1 50FC/XR550FC Series input and output circuits. Additional surge protection is available by installing the DMP 370 or 370RJ Lightning Suppressors. 3.3 Network Protection The Model 270 Network Transient Suppression Module protects the XR1 50FC/XR550FC panel from surges on the ETHERNET port. XR l5OFCIXR55OFC Series Installation Guide Digital Monitoring Products 3 II.1STLLTIO11 - Installation 4.1 Mounting the Enclosure The metal enclosure for the XR1 50/XR550 Series must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the panel PCB when installing the enclosure. Figure 2 shows the mounting hole locations for the Model 350/350A Enclosures. Figure 3 shows the Model 341 Kiosk Enclosure. Figure 4 shows the Model 352X panel cabinet and 3525 shelf cabinet for multiple batteries. The 350A Attack Resistant enclosure is factory shipped with one knockout on the top left of the enclosure. As needed, additional knockouts or antenna exits may be added at the time of installation. See Figure 2 for the positions on the enclosure that can be added. Each additional knockout must be filled with conduit. ,fl Enclosure Mounting Holes o i o XR550 Panel ED 3-Hole o P. G -D '— Pattern for Accessory - Modules o U I! Dual 13/4" and 13/8" Conduit Knockouts * 350A Optional Knockout Front and Rear Tamper 0 0 Switches for 350A Attack Resistant Enclosure * Battery Shelf holds up to three 7 Ah Batteries ' Figure 2: XR550 Series in Model 350 or 350A Enclosure Ps for optional battery bracket See 341 Installation sheet for °Lid Mounting Holes (4 places) additional information. 0 _J d Mounting Holes (4 places) 0 Q 0 / 0 ii Dual 1/2 and 3/4 Conduit Knockouts / Figure 3: XR550 Series in Model 341 Enclosure XRI50/XR550 Series Installation Guide Digital Monitoring Products 7 o r-o XR550 Panel 0 .,— - - flJlLJ E o 9, Enclosure Mounting Holes (4 Taces)>,/ 6.8 (Power Reciuire During AC power failure, the XR1 50/XR550 Series panel and all connected auxiliary devices draw their power from the battery. All devices must be taken into consideration when calculating the battery standby capacity. The following table Lists the XR150/XR550 Series panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. Standby Battery Power Calculations Standby Current Alarm Current 1XR550i Control Qty 1 x [7jrl 2jmA Qty _1 x 17rnj2iLmA Relay Outputs 1-2 (ON) Qty _______ 30mA Qty _______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones 1-8 Qty _______ 1.6mA Qty _______ 2mA* Active Zones 9-10 Qty _______ 4mA Qty _______ 30mA 2-Wire Smoke Detectors Qty _______ 0.1mA Qty _______ 0.1mA Panel Bell Output 1500mA mA 893A Dual Phone Line Module Qty _______ x 12mA Qty _______ x 50mA 263LTE Cellular Communicator Qty x 13mA Qty _______ x 13mA 263H HSPA+ Cellular Communicator Qty x 24mA Qty _______ x 28mA 277 Buzzer Module Qty _______ x 5mA Qty _______ x 5mA 1100X Wireless Receiver Qty _______ x 46mA Qty _______ x 46mA 1100XH Wireless High Power Receiver Qty x 160mA Qty _______ x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty _______ x 34mA All four relays active 138mA 138mA 865 Style Y or Z Notification Module Qty x 26mA Qty _______ x 85mA 866 Style W Notification Module Qty x 45mA Qty _______ x 76mA 867 LX-Bus Style W Notification Module Qty x 30mA Qty x 86mA 869 Dual Style D Initiating Module Qty _______ x 25mA Qty x 75mA 630F Remote Fire Command Center Qty x 63mA Qty _______ x 92mA 7060/7160 Thinline/7060A Aqualite Keypad Qty _______ x 72mA Qty _______ x 80mA 7063/7163 Thinline/7063A Aqualite Keypad Qty x 85mA Qty _______ x lOOmA 7070/7170 Thinline/7070A Aqualite Keypad Qty x 72mA Qty _______ x 87mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7073/7173 Thinline/7073A Aqualite Keypad Qty x 85mA Qty _______ x 100mA* Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA 7760 Clear Touch Keypad Qty x 65mA Qty _______ x 115mA 7872 Graphic Touchscreen Keypad Qty _______ x 130mA Qty _______ x 188mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7873 Graphic Touchscreen Keypad Qty _______ x 130mA Qty _______ x 188mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 734 Wiegand Interface Module Qty x 15mA Qty _______ x 15mA Active Zones (EOL Installed) Qty _______ x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty ________ x 20mA 734N Wiegand Interface Module Qty _______ x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty _______ x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty x _______ 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA 734N-WiFi Wiegand Interface Module Qty _______ x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty x 2mA* Annunciator (ON) Qty x 20mA Wiegand Reader Qty x 200mA Qty x 200mA Copy Sub-Totals to next page Sub-Total Standby ______mA Sub-Total Alarm mA E *Based on 10% of active zones in alarm. Digital Monitoring Products XRI50IXR550 Series Installation Guide 12 INSTALLATION Standby Battery Power Calculations Standby Current Alarm Current 736P POPIT Interface Module Qty x 25mA Qty _______ x 25mA Radionics Popex, POP1Ts, OctoPOPITs Qty _______ x __mA Qty _______ x __mA 738A Ademco Wieless in, tdffàce ModUle Qty x 75mA. ______ Qty x 75mA. 738Z Z-Wave Interface Module Qty x 35mA Qty _______ x 35mA 763 Wi-Fi Module . Qty ______ x 31mA Qty x 31mA 710 Bus Splitter/Repeater Module Qty x 32mA Qty _______ x 32rnA 711 Zone Expansion ModuleL.. . Qty _______ x ilmA. ~Actiye,;W(~~EOL 711mA Qty x Installed) .Qty ______ x Qty ______ x . 2mA' 714 Zone Expansion Module Qty x 7mA Qty _______ x 7mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* 712-8 Zone Expansion Module Qty . . . . x 17mA . Qty _______ x 17mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA 714-8, 714-16 Zone Expansion Module Qty x 20mA Qty _______ x 20mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* 715 Zone Expansion Module Qty ______ x 7mA . Qty ______ x 7mA_ Active Zones (EOL Installed) Qty x 4mA Qty _______ x 30mA* 2-Wire Smokes. . Qty _____. x .1mA• Qty . x .1mA 715-8, 715-16 Zone Expansion Modules Qty x 20mA Qty _______ x 20mA Active Zones (EOL Installed) Qty x 4mA Qty x 30mA* 2-Wire Smokes Qty x .1mA Qty ______ x .1mA 716 Output Expanion Module Qty _______ x 13mA Qty _______ x 13mA Active Form ç Relays. . . . Q , _______ x 12rnA 717 Graphic Annunciator Module Qty x lOmA Qty _______ x lOmA Annunciator Outputs Qb,' _______ x imA 2W-BLX, 2WT-BL)( Smoke Detectors Qty _______ x 11m4: Qt' x 31mA* COSMOD2W Module Qty x 45mA Qty ______ x 174mA*# COSMO-2W. Smoke and CO Detectors Qty . x. 1mA, Qty . x 50mA*# 572 Indicator LED Qty x 20mA Qty _______ x 20mA Aux. Powered Devices on Terminals 7 and 11 . mA mA Other than Keypads and LX-Bus Modules Sub-Totals this page Sub-Total Standby mA Sub-Total Alarm ______mA Sub-Totals from previous page Sub-Total Standby ______mA Sub-Total Alarm mA *Based on 10% of active zones in alarm Total Standby mA Total Alarm _______mA # For systems that are not central station monitored, multiply alarm current by 12. - Total Standby mA x number of Standby Hours needed = mA-hours Total Alarm mA + mA-hours Total mA-hours X .001 = __Amp-hrs Required Refer to section 6.9 for standby battery selection. XRI50IXR550 Series Installation Guide Digital Monitoring Products 13 SECURITY SIGNALING 0 USTED Simple Expansion f iI Solutions Ir Expand your DMP panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, glassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 modules. II*N j1:F,1 [•1 U [.1 '1'J I T__ ZONE EXPANSION MODULE FEATURES Provides Class B ones for burglary and fire Compatible with DMP Panels that allow zone expansion Suitable for mouting near protection devices Connect devicesusing 4-wire bus Easily mount attractive cases on wall or 3-gang box Compatible with all panel zone types Easy connection o 4-wire Keypad or LX-Bus Proven design ensures stability and performance Data LED on zone expander indicates good panel communication Durable and attractive plastic or metal housing Low current draw Can be powered from panel or auxiliary power supply _E LE _TCCFDA0& 171 S 0 ..' USE ON THE DMP LX-BUSTM 708 BUS EXTENDER MODULES 710 The modules can be used on the LX-Bus The 708 Bus Extender Modules allow you As a splitter, the 710 provides superior of DMP Panels. The modules connect to to increase the length of wire used to run mechanical wire connecting capability the 4-wire bus and use only one zone an LX-Bus or keypad bus by a maximum of for up to three additional 12 VDC LX- address. To assign an additional zone 4,000 feet, while providing immunity to Bus or keypad bus circuits. This makes expander use the next available zone noise on the wires. The 708 Bus Extenders the 710 module an excellent junction address. are received from the factory as a pair of box when terminating multiple LX-Bus/ mndiiIc that connect between the nin4 kvnd hiic runs it one lnratinn. CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714,714-8,714-16,715, 715-8, and 715-16 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic' housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the covers go on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708 and 710 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1 R Receivers. and LX-Bus or keypad bus devices. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710 BUS SPLITTER! REPEATER MODULE The 710 Bus Splitter/Repeater Module allows you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710 Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included S EP' EE SD-fl EE EE U 714/715 ZONE EXPANDERS 714-8,714-16,71 5-8, AND 714-8,714-16,715-8, AND The 714 contains four Class B burglary 715-16 DESCRIPTION 715-16 FEATURES zones and is suitable for use with burglary The expanders are housed in a Model 8 or 16 protection zones per and fire devices that are normally opened 340 locking metal enclosure suitable expander or normally closed. Individual zones are for mounting in a remote Location. Durable metal enclosure housing supervised with 1k Ohm EOL resistors and Each expander provides screw terminal with lock and key can be programmed with any burglary or strips for zone inputs and data bus Individual screw terminals fire zone type. connections, a two position jumper to accommodate 14 to 22 gauge wire The 715 contains four Class B powered designate connection to the keypad bus for easy connection zones and is suitable for use with 12 VDC, or the LX-Bus, and an LED to indicate Suitable for mounting in a remote 2-wire smoke detectors and non-powered communication with the panel. Separate location fire or burglary devices. Individual zones zone End-of-Line resistors are included DESCRIPTION) on the 715 are sunervised with a 3.3k with each expander. 7 . 4A.JI Ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 7201 Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 7201. 7141715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8/714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8/715-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. i He i ii LUIIC CXIJdiiiUiI IVIUUULC LUiiIiC(LS to the panel's 4-wire Keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing _ Digit.I Mai*arIn Product. 6ALVA QVVU_91! - On 7141715 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714 Average 7mA+ 1.6mA per zone Alarm 7mA + 2mA per zone 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 7mA + 58mA per shorted zone +.0. 1 per 2-wire smoke + 30mA per smoke in alarm Dimensions 4.5" X 2.75" X 1.75" 714-8, 714-16, 715-8, AND 715-16 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714-8/16 Average 20mA + I .6mA per zone Alarm 20mA + 2mA per zone 715-8/16 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 20mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Enclosure 20-Gauge cold-rolled steel Dimensions 12.5" W x 11.5" H x 3.5" D 714-8/-16 Color Gray 715-8/-16 Color Red LISTINGS AND APPROVALS Refer to the appropriate panel programming and installation guide for specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshall (CSFM) New York City (FDNY COA #6055) (711, 714, 715 only) Underwriters Laboratories (UL) Listed For additional information, access www.dmpcom and select Compliance. 0 ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-Hole Plastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC ALL DMP 12 VDC 710 N/A N/A Yes Yes 712-8 Dip Switch 8 Yes No 12 VDC XT Series and XR100/XR500 Series 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B MODULE SPECIFICATIONS 708 SPECIFICATIONS (NON-UL) Operating Voltage 8.8 to 15.0 VDC Operating Current 20mA Per Pair Dimensions 45"X 2.75" X 1.75" Maximum Distanc& 4,000 feet between the two 708 Modules 710 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 710 30mA Dimensions 4.5" X 2.75" X 1.75" Distance 2,500 feet (one modiilé), 15,000 feet maximum Ii I SPECIFICATIONS OperatingVdltage 8.8 to 15.0 VDC Operating Current g. .. EAtarm iA+1.6mAperactiveth ) . (11mA+ 2mA per zone in alarm) Zone Voltage 5 VDC (1 6mA across EOL) Dimensions 4.5" X 2.75" X 1.75" - 712-8 SPECIFICATIONS Operating Voltage &8 to 15.0 VDC Current Draw 17mA + I 6mA per active zone 17mA + 2mA per zone in alarm Dimensions '' 4.5" H x 2.5" W 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. [7165-1157:0135) Page 1 of 2 CATEGORY: J7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: (Digital Monitoring Products)lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com DESIGN: (Models XR10) XR350 and XR550(combination fire and burglary alarm control unj Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure (630F: Supervised LCD Keyp 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers __ 714, 714-8, 714-16, 715, 715-8, 715-16! Zone Expanders) *711S: Zone Expander (NOT for use with XR350) Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 2631-1: Cellular Communicator (May be used as the standalone primary communicator) 263LTE: Cellular Communicator (NOT for use with XR350) (May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 fQigExpJ 30, 2021) Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 (June 30, 2021 ) Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division AIR PRODUCTS AND ONTROLS LDUCT 2000 SERIES SMOKE DETECTORS / f You /in Control H/-Temp, Low-F/ow& No- Tools PRODUCT APPLICATION - The SL-2000 Series Conventional Duct Detector , is the latest innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and - Residential applications. The unit is designed to prevent '--... the recirculation or spread of smoke by air handling - - systems, fans and blowers. Complete systems maybe shut down in the event of smoke detection. The SL-2000 is designed and built to meet all local code requirements, as well as the NEPA and ICC standards regarding HVAC supply and return duct smoke detectors. Output terminals are provided for a wide range of remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or push buttons. PRODUCT DESCRIPTION The SL-2000 includes many features that represent true 4-. .-- innovations from current generation duct smoke detectors. Our traditional installer/servicer-friendly approach has been closely followed and expanded - throughout the SL-2000. This philosophy provides a new level of efficiency in after-purchase value to both the installer/servicer and end-user. Our attention to --t detail has yielded a host of "No-Tools Required" Mum features, as well as a murti-application performance 0 @,CSFM LISTED MEA ACCEPTED level as yet unmatched in the industry. Innovative product combined with unsurpassed customer service equals the right combination for all of your projects. The key features below detail many of the customer-driven innovations incorporated in the SL-2000 Series. FEATURES Low-Flow Technology: Both Ionization and Photoelectric models listed for velocities between 100-4000 ft./min + Both models listed for high-temperature applications + Operating voltages: 230VAC, II SVAC, 24VAC, 24VDC + Interconnect up to 30 units for common functions + Patented "No-Tools Required" front or rear loading and removing sampling/exhaust tubes + Patented "Test Port Valve" allows for aerosol smoke testing without cover removal + Clear cover fitted with four captive "No-Tools Required" thumbscrews + Instantaneous cover: removal trouble indication + Staggered terminal blocks for easier wiring Flashing LED on detector head indicates normal operation Magnet test capability (magnet included) + More wiring space than competitive models + Footprint allows easy retrofit in many applications without additional drilling + Over IS remote accessories available + Duct wall gaskets on back of enclosure are pre-installed + Compatible with the WP-2000 weatherproof enclosure Air Products and Controls is a Brand of Apollo America A 25 Corporate Drive Auburn Hills, Ml 48326 HALMA (248) 332-3900 Phone GROUP (888) 332-2241 To// free (248) 332-8807 Fax COMPANY www.ap-c.com .. Reset switch is also an alarm test switch - competitive models require a magnet or cover removal to test at unit + Unit includes green pilot and red alarm visual indicators + External mounting tabs do not require cover removal to install + Colored cover gasket indicates proper cover seal + UL, CUL, CSFM, and MEA Listed + Compact, lightweight size means easy handling, lower shipping costs + Two sets of I OA form "C" alarm contacts + One set of 2A form "A" alarm contacts One set of I OA form "C" trouble contacts + Large terminal connection screws + Standard interchangeable "plug-in" UL268 photoelectric or ionization heads + Advanced detector head design yields internal dust filtering + No additional screens or filters to clean + Compatible with building automation and fire alarm systems + Ionization and Photoelectric versions available + Complete wiring details permanently attached to unit Distributed By: REMOTE ACCESSORY WIRING INTERCONNECTION WIRING /COMMON FUNCTIONS POWER M220Q4 C ake ,o,e 0 000 OPTR00ICDRTUULIOI000000AOAOe00OTOO NAek.suns OCT0TAdWTO00IP0O00 N 0UPP j RED BUZZER 4 @ .6Tj D-2'......... 'AC :RaED IS @ 0 r@ r@ ALARM (8 - P- - H LED 19 BLACK ALARM MPER ___ CONDITION. I 05 0IaTT 00/, Oporalo wilh &T5IO All 0101111 RIOYE opthole 0i11 01T50 I~KEI L5K (\_..—fit/ '(5I YELLOW I 0/OTT. 11dM/A/Ihom/ATobaOTtle eIeTT. 0/I horn/AROSe OP/IC ED '-_-' ''TROUBLE I ope,aleop oBTpeddeto0bOrAlIy. opelaIooToTyeIn9IRoIoTT OR A GREEN I LEO I ebRA 30 do/Rol,, TOE PUU1TON PILOT (i/,UNITA1 IJNR02 UNITBX SIN/TOO UNITB2 UNETIIX 'TEST LED °'° BLACK ®..._®........® O-®_-(....,...® TROUBLE ®i5'O ®jCfii CANNOT SE CONNECTETROUBLECOUTACTSD €t TO FIRE ALARM PANEL AU alarm relaya operate 0,4th elfle CommUl beS/W800 30 deleOlOrSlTao. TEST I RESET PILOT WITHOU CIOIPb• 30 dobeolore TOO. (ueo TOT0010/ open I000IreSeI So/ICR) T THE USE OF A WIRING o TOATROUBLE bA ALARM POWER INPUT CONTACT CONTACT 2AVACOIDC = S NC C NO NC C NO I I III II I 0 1 2 3 415 6 718 9 10 G 220 115 11 12 13 14 15 16117 18 19 20 I°I OAPACP IRA ALARM AUX POWER ALaRM ALA/WI CONTACT OUT LINK CONTACT PRODUCT SPECIFICATIONS MODEL NUMBER: SL-2000-N Ionization: 230VAC, 115VAC, 24VAC, 24VDC (SL-2000-P (PhotoelectriE23OVAC115VAC, 24VAC, 24V SrI"Tf'C RA/"SI'bI FII IR,1DD. CI _)Aflfl_M rlZrInn_°)')P,0CN SL-2000-P 55000-328AP0 SAMPLING TUBES: FAST Tube Sectional sampling tube, kit fits up to 90" duct width STN-1.0 Sampling tube for 12' or less duct width STN-2.5 Sampling tube for 6" to 2.5' duct width STN-5.0 Sampling tube for 2.5' to 5.0' duct width STN-10.0 Sampling tube for 5.0' to 10.0' duct width ACCESSORIES: MS- and MSR-Series remote accessories, WP-2000 weatherproof enclosure, TG-2000 aerosol test gas, and T-PB power supplies (All available from Apollo America) POWER REQUIREMENTS: (without accessories) 230VAC 12 mA Standby: 115VAC 22 mA 24VAC 55 mA 24VDC 14 mA Alarm: 230VAC 18 mA 115VAC 32 mA 24VAC 190 mA 24VDC 68 mA RELAY CONTACT RATING: Alarm Contacts: Resistive load: 2 sets form "C" rated at 10 Amps © 115VAC Resistive load: I set form "A" rated at 2 Amos Polh( VLL)UI I Y: iou to 4,000 rumln. AMBIENT TEMPERATURE: SL-2000-N 32°F to 158°F (0°C to 70°C) SL-2000-P 32°F to 140°F (0°C to 60°C) HUMIDITY: 85 ±5 % RH (@32 ±20,C; 86 ±3.6°F) Non-Condensing I Non-Freezing WIRING: Solid or stranded: #12 to #22 AWG terminals APPROVALS: UL & CUL Listed (UL268A, UROX, UROX7) File # S2829 CSFM Listed (3240-1004:105) Do not expose to corrosive atmospheres HARDWARE: 7" exhaust tube, sampling tube end cap, mounting template, test magnet, and mounting hardware included ENGINEERS & ARCHITECTS SPECIFICATIONS Air duct smoke detectors shall be Air Products and Controls SL-2000 Series. For ionization detectors the model number is SL-2000-N. For photoelectric detectors the model number is SL-2000-P. The detectors shall be listed by Underwriters Laboratories per UL 268A. The detectors shall operate at air velocities from 100 feet per minute to 4,000 feet per minute and at temperatures of no greater than 140°F (60°C). Visual indication of alarm and power must be provided on the detector front. A manual reset switch shall be located on front of the device. Detector head shall not require additional filters or screens which must be maintained, and shall include both a standby and alarm visual indication. The housing shall contain a detector base which will accept photoelectric or ionization detector heads. Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote pilot, remote alarm indications, strobe/horn, and remote test/reset switch. All wiring must comply with local codes and regulations. A method of testing the alarm function with a magnet must be provided. A method of smoke testing the detector without removing the cover must be provided. - All unit, remote accessory, and common function connection designations must be permanently affixed to the unit. Cover and sampling/exhaust tube installation or removal must not require the use of tools. Capability for interconnection of up to 30 units shall be provided for common functions. Sample and exhaust tubes shall be capable of removal/installation from the front and/or rear of the detector for inspection/maintenance. NOTICE: The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific inatructionahinstallation documentation, which covers various technical, approval, code, limitation and liability information. Copies of this documentation along with any general product warning and limitation documents, which also contain important information, are provided with the product and are also available from Apollo America The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning the products, contact Apollo America. Apollo America reserves the right to change any and all documentation without notice. ©Apollo America 2013 DS-DU-1 H080424 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 240-1004:01O Page 1 of 1 CATEGORY: (3240 -- DUCT SMOKE DETECTOR H0USING/BASE1 LISTEE: (Apoo America Inc.25 Corporate Dr., Auburn Hills, Ml 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models RWH-N, RWH-P, RWL-N, RWL-P, RWX-N, RWX-P, RWJ-N, RWJ-P, RWF-N, RWF-P and SL-2000-N andtSL-2000-P duct smoke detectors All units are four-wire duct detectors. Suffix -N indicates the unit employs an ionization smoke detector head. Suffix -P indicates the unit employs a photoelectric smoke detector head. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VAC, 24 VDC, 115 VAC or 230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as duct detectors for use with separately listed compatible fire alarm control units when installed in HVAC systems with air velocity between 500 and 4000 ft/mm. *The Model SL-2000-N duct detectors are suitable for use in ducts where the air velocity is between lOOft/min and 4000ft/min. When the air deflector is used, the air velocity range is between lOOft/min and 2000ft1min. When not used, the range is between 300 ft/min and 4000ft/min. *The Model SL-2000-P duct detectors are suitable for use in ducts where the velocity is between lOOft/min. and 4000ft/min. When the air deflector is used, the air velocity range is between lOOft/min and 4000ft/min. When not used, the range is between 1000 ft/min and 4000ft/min. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 08-15-2007 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not : an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 (jJingExpJpj (June 30, 2021) Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division VA II C'I'RACI'Ol{S MRE & CABLE Product Specification Issued: 1994 FIRE ALARM UNSHIELDED, RISER RATED PART NUMBER: (FPL112ó DESCRIPTION: f2I1SoIid FPLR Cable) CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor (IAWG bare coppj Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.060" Number of Conductors Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter ______ Approximate Cable Weight (lbs.!Kft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20t 6.43 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 C to 60 C Insulation Colors Chart 2 Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT EX6418X (UL) 18AWG TYPE FPLR DEVICE A B C C E F ZONE 0 12 34 56789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Contractors Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Contractors Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: August 20, 1994 CONTRACFORS WIRE 6 CABLE 6611 Preston Ave Ste A Livermore, CA 94551 Ph: (800) 444-8816 Fax: (925) 454-3444 www.contractorswire.com X7-M'1tiWI1)RS WIRE & CABLE Product Specification Issued: 1994 FIRE ALARM JACKETED UNSHIELDED PART NUMBERI_FPL11 DESCRIPTION: (4/18 Solid FPLR Cable) CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable. Construction Parameters: Conductor (18 AWG bare copp Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated CondL'ctor Diameter 0.060" Number of Concuctors Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" Nom. Overall Cable Diameter i0.19" Approximate Cable Weight (lbs .IKft.) 35 Flame Rating UL 1581 vertical tray flame test. !IectrIcaI Properties: Nom. DC Resistance per Conductor @ 201C 6.43 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 35 pFlft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 C to 60 °C Insulation Colors Chart 2 Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT EX6418X (UL) 18AWG TYPE FPL DEVICE A B C D E F ZONE 0 12 34 56789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Contractors Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Contractors Wire & Cable. Customer Name Date Signed Customer Approval Specification issue Date: August 20, 1994 €ONTRAfl1111{S 40k.WIRE 6 CABLE 6511 Preston Ave Ste A Livermore, CA 94551 Ph: (800) 444-8816 Fax: (925) 454-3444 www.contractorswire.com