Loading...
HomeMy WebLinkAbout2236 RUTHERFORD RD; 103; FPC2019-0189; PermitCARLSBAD, CA 92008-8836 Work Class: Fire Sprinklers Track U: Lot U: Project U: Plan U: Construction Type: Orig. Plan Check U: Plan Check #: Print Date: 10/17/2024 Job Address: 2236 RUTHERFORD RD. # 103, Permit Type: FIRE-Construction Commercial Parcel U: 2120612600 Valuation: $355,801.50 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2019-0189 Status: Closed - Finaled Applied: 08/08/2019 Issued: 08/20/2019 Finaled Close Out: 04/08/2021 Final Inspection: INSPECTOR: Salcedo, Felix 112 4: okl~ Oki c7city of Carlsbad Project Title: Description: VESSEL BRANDS 7 SPRINKLER TI (27 HEADS) COMBINE SUITES 103 & 105 INTO SUITE 103) Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAZZMIN DEEKEN 9925 PROSPECT AVE, U STE B 9925 PROSPECT AVE, U B SANTEE, CA 92071 SANTEE, CA 92071 . (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: 1 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov 19~0 1 01, __ 0 18 11 tqco Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch {12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet 1FP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.61K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/barll2) FEBRUARY 2014 Temperature Rating 135°F(57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 2-7/8" (73,0 mm) DIA. -j TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 I (11,1 mm) /79 NOMINAL U II 11 L1 ____ MAKE-IN mm) t. iJ _ 2 _ g (50,8 mm) w 1/2 NPT** DEFLECTOR* STYLE 150r20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) ___________ FLUSH 3/8±5/16" (9,5±7,9 mm) MOUNTING/) \ 1/8" j I SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING - (57,2 mm) 5/16±1/4" / \ I 1/2(12,7mm) (7,9±6,4 mm) I II FLUSH MOUNTING \ ',: "- SURFACE \_ (3,2mm) CLOSURE SERIES MOUNTING 1-3/8"(34,9mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON I I TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 I 5.6K UPRIGHT (1/2NPT) TY313 PURE WHITE (RAL9O1O)** POLYESTER 371 5.6K PENDENT (1/2 NPT) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqcu Worldwide www.tyco-fire.com Contacts Series TYB - 2.8.1 5.6., and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in herein are standard response, standard coverage, decora- tive 5 mm glass bulb-type spray sprin- klers. They are designed for use in light, ordinary, or extra-hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The TY-B Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjust- ment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series TY-B 2.8, 5.6, and 8.0 K-fac- tor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contract the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Numbers (SIN) TY1151 ... Upright 2.8K, 1/2 in. NPT TY1251 .. .Pendent 2.8K, 1/2 in. NPT 1Y3151 ... Upright 5.61K, 1/2 in. NPT TY3251 .. .Pendent 5.6K, 1/2 in. NPT TY4151 ... Upright 8.01K, 3/4 in. NPT TY4251 . . .Pendent 8.0K, 3/4 in. NPT TY4851 ... Upright 8.01K, 1/2 in. NPT TY4951 . . .Pendent 8.0 K, 1/2 in. NPT JULY 2018 Technical Data Approvals UL and C-UL Listed FM, LPCB, VdS, and NYC Approved Refer to Table A for complete approval infor- mation, including corrosion-resistant status. Maximum Working Pressure Refer to Table B Discharge Coefficient K=2.8 GPM/psi½ (40,3 LPM/barY') K=5.6 GPM/psi½ (80,6 LPM/bar½) K=8.0 GPM/psi/2 (115,2 LPM/bar") Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb ...............................Glass Compression Screw .................Bronze Deflector .........................Copper Bushing (K=2.8) ....................Bronze TFPI5I UPRIGHT * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on ESCUTCHEON special request. PLATE SEATING SURFACE 7/16' _ _H11,1 mm) OMINAL 2-3/16 MAKE-IN —1(556 mm7/ (55,6 mm) 2-3/16 1-1/2 I (38,1 mm) ___ 1 4 t WRENCH FLATS PENDENT RI2 4 STYLE 10 -- 2-7/8 (73,0 mm) DIA. -.- RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 1/2 NPT* 2-7/8' (73,0 mm)DIA. RECESSED PENDENT CROSS SECTION TFP15I Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7/16 ________ / 2-1/4 _T // I 1 4-Bulb 1,1 mm) (57,2 mm) * Temperature rating is 7 3 - Sealing 6 - Deflector* Assembly 7 - Bushing 4 NOMINAL MAKE-IN ' 1-9/16 _______ indicated on Deflector. 23/16 (39,7 mm) _____ (55,6 mm) ** Pipe thread connections 6* per ISO 7-1 can be provided on special 1/2 NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TV-B UPRIGHT (TYI15I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE ALL FINISHES EXCEPT POLY-STAINLESS UPRIGHT WRENCH 1/2' ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated / I 7/16' 1,1 mm) OMNAL 2-3/16 SURFACE 4 - Bulb 6 - Deflector* on Deflector. 4AKEIN (55,6 mm) 2-3/16' 1-1/2' I (55,6 mm) (38,1 mm) I H _ STYLE 10 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TV3251) SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI5I Page 3 of 8 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 111 TT 1/2 _ (12,7mm) I NOMINAL 2-1/4 (58,7 mm) 1-9/16' I MAKE-IN ______ f 2-5/16 (57,2 mm) (39,7 mm) 3/4" NPT** WRENCH STYLE 40 -.---- 2-7/8 (73,0 mm) DIA. -.- FLATS RECESSED • UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated :k 1 1/2" \/ SURFACE 4 - Bulb 6 - Deflector * on Deflector. (12,7 mm) I NOMINAL I 2-5/16' MAKE-IN I _1 (58,7 mm) 2-1/4" 1-9/16" I (57,2 mm) (39,7mm) STYLE 40 RECESSED UPRIGHT PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TV-B UPRIGHT (TV4151) AND PENDENT (TV4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 3 - Sealing 6 - Deflector* Assembly i I 4 - Bulb 2-1/4" (57,2 mm) * Temperature rating is 1-9/16" indicated on Deflector. (39,7 mm) I 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. CROSS SECTION I71\ 7/16" I (11,1 mm) I NOMINAL I MAKE-IN 11/ I 2-3/16" (556 mm/ LN d 1/2" NPT** WRENCH FLATS UPRIGHT PENDENT FIGURE 4 SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE TFPI5I Page 4 of 8 - 2-7/8" DIA. 5/8±1/4' (73,0 mm) 3/4" (19,1 mm) DIA. (15,9±6,4 mm) 2-1/4' 1/4" (6,4 mm) R FACE OF (57,2 mm) MOUNTING SPRINKLE PLATE FITTING (3,2 mm) 7 MOUNTING SURFACE SERIES 1-1/4"(31,8 mm)1 CLOSURE TV-B 3/4' (19,1 mm) FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. 5/8±1/4" (73,0 mm) 1 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57 2 mm) FACE OF I I MOUNTING SPRINKLER L. .7.) .- PLATE FITTING 1/811 I - ____ ____ ______ MOUNTING -' SURFACE// -. CLOSURE SERIES 1- 5/16 (33,3 mm) 13/16" (20,6 mm) FIGURE 6 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel" Bulb...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the Style 10 or 40 Recessed Escutcheon, as applicable, for recessed pendent installations. Installation The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum TFPI5I Page 5 of 8 K Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish8 _____________ t Natural Brass __________________________ I Chrome Plated olyesterc Poly-Stainless Lead I Coated Wax Coated I Wax-Over- Lead Coated 135° F (57°C) Orange 2.8 1/2 in, NPT Upright (TY1151) and Pendent (TY1251) 1, 2, 3 N/A N/Ad 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange Upright (TY3151) 1,2,3,5 1,2,3,5 155°F (68°C) Red 175°F (79°C) Yellow 5.6 1/2 in. and Pendent (TY3251) Figure 2 1, 2, 3, 4, 5, 6, 7 1,2 Green 1,2,3,5 200°F (93°C) 286°F (141°C) Blue ib, 2b, 3b, 5b ib, 2b, 3b, 5b 360°F (182°C) Mauve N/A NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3251)a 1, 2, 3,4,5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F(57°C) Orange 8.0 3/4 in. Upright (TY4151) and Pendent (TY4251) Figure 3 155°F (68°C) Red 1,2,3,4,5,6,7 1,2 Green 1,2,5 1,2,3,5 1,2,5 175°F (79°C) Yellow 200°F(93°C) 286°F (141°C) Blue lb, 2b, 3b, 5b 1 , 2b, 5b 360°F (182°C) Mauve N/A NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4251)a 1,2,3,4,5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red 8.0 1/2 in. NPT Upright (TY4851) and Pendent (TY4951) 1, 2, 3, 4, 5,6 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F(182°C) Mauve NOTES Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by FM Global (FM Approvals). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 1011/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable 150'F (66'C) maximum ceiling temperature Frame and deflector only Not Applicable (N/A) TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 6 of 8 Sprinkler Finish K Type Natural Brass Chrome I Polyester' Lead I I Wax I Wax-Over-Lead Coated Coated Coated 2.8 Upright (TY1151) 1/2 in. and 175 psi (12,1 bar) N/A3 NPT Pendent (1Y1251) Upright (TY3151) and 5.6 Pendent (TY3251) 250 psi (17,2 bar)2 1/2 in. or NPT 175 psi (12,1 bar) Recessed Pendent (TY3251) Upright (TY4151) and 175 psi (12,1 bar) 8.0 Pendent (TY4251) 3/4 in. NPT I Recessed Pendent 175 psi (12,1 bar) N/A (TY4251) 8.0 Upright (TY4851) 1/2 in. and 175 psi (12,1 bar) NPT Pendent (TY4951) NOTES Frame and deflector only The maximum working pressure of 250 psi (17,2 bar) only applies to :he Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. Not Applicable (N/A) TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE torque of 10 to 20 lb-ft (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TV-B Upright and Pendent Sprinklers Installation The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7). For wax-coated sprinklers, use an 8 or 10 in. adjustable wrench. With reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, to the sprinkler wrench flats. Wax Coated Sprinklers When installing wax-coated sprinklers with an adjustable wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprin- kler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod in order to prevent the installer from being burned. TFPI5I Page 7 of 8 Series TY-B Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, apply the W-Type 7 Recessed Sprin- kler wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Recessed Pendent Sprinkler and push the Closure over the Mount- ing Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. I I TFPI5I Page 8 of 8 P/N 57 - XXX - X - XXX 'SIN SPRINKLER TEMPERATURE FINISH I RATING 1 NATURAL BRASS 135 135°F (57°C) POLY-STAINLESS GREY 155 155°F (68°C) 2 ALUMINUM (RAL9007)1 570 5.6K UPRIGHT (1/2 in. NPT) TY3151 POLYESTER - ___________________________ 175 175°F (79°C) PURE WHITE (RAL9010)2 571 5.6K PENDENT (1/2 in. NPT) 1Y3251 - POLYESTER 200 200°F (93°C) SIGNAL WHITE (RAL9003) 590 8.0K UPRIGHT (3/4 in. NPT) TY4151 - POLYESTER 286 286°F (141°C) JET BLACK (RAL9005)3 591 8.0K PENDENT (3/4 in. NPT) TY4251 - POLYESTER 360 360°F (182°C) 6 WAX COATED 560 8.0K UPRIGHT (1/2 in. NPT) TY4851 - 286°F (141°C) MAX 000 OPEN4 7 LEAD COATED WAX-OVER-LEAD 8 286°F (141°C) MAX 9 CHROME PLATED NOTES Only available on TV3151, TY3251, 1Y4151, and TY4251. Eastern Hemisphere sales only. Available in only 8.0K, 155°F (68°C) or 200°F (93°C): requires lead time to manufacture. Available only for 8.0 K-factor TY4151 and TY4251 for use in delJge systems (OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly). TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 530 2.8K UPRIGHT (1/2 in. NPT) TY1151 531 2.8K PENDENT (1/2 in. NPT) TY1251 561 8.0K PENDENT (1/2 in. NPT) TY4951 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 which is 150°F (66°C). Controls Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench- damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1- 286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F (141 OC) sprinklers is the same as for200°F(930C) sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F(930C) sprinkler 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and other Information shown were current soot document revision date and are subject to change wIthout notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA ore registered trademarks I National Pro ProlecEon Acsaclatiunl TEFLON iso registered IrodomarA of DuPont El Malleable Iron Threaded Pipe Union: Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar .200 to 1500 28.90 to 300 20.7 65.60 500 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34. 3000 148.90 185 12.8 360 24,8 460 31.7 3500 176,70 150 10.3 315 21.7 415 28.6 400° 204.4° 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 550° 287.8° - - 130 9.0 230 15.9 Note: Unions with Copper or CopperAlloy seats are not intended for use where temperatue exceeds 450°F c®us <:i3~> APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Represeitatiwe,, Malleable Iron Threaded Fittings Pr)ssure - Temperature Ratings Temperature Pressure Class 150 Class 300 ___________ Sizes 'A-i (6-25 mm) Sizes 11A- '32-51 mci) Sizes 21/x'_3 164-76 mm) (°F) (°C) .'psi bar psi bar psi', bar psi bar -200 -28.90 to to 300 20.7 1500 65.60 2,000 137.9 1,500 103,4 1,000 68.9 200° 93.3 265 18.3 1,785 123.1 1,350 931 910 62.7 2500 121.1 225 15.5 1,575 108.6 1.200 82.7 825 56.9 300° 148.9 185 72.8 1,360 93.8 1. C50 72.4 735 50.7 350° 176.7 150: 10.3 1,150 79.3 900 52.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 550° 2878 - - 300 20.7 300 20.7 300 20.7 Anvil Class 1E0/00 Malleable Iron Fitti-tgs coiform to ASME B16.3 and Un Dns conform to ASME B16.39. ALL ELBOWS & TEES /8" (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) PF-11.10 TO ct-4 best sprinkler" in the industry' F c®usLISTED <> APPROVED no /4ONFSA - Fs. NFPA s. BULL MOOSE TUBE COMPANY -I - Am WA Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 el c®us LISTED <> APPROVED [] A., ONFSA £,,_._, Fn NF I BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler-pipe is produced10 - meet sprinkler pipe standards and applications. c®us LISTED <> APPROVED col A ONFS4 NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARIJ Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube9 reserves the right to change product specifications without notice and without incurring obligation. H .w=i.i:i. c®us LISTED <> APPROVED ] 4NONFSA MI-I_a .i • Alnsdes,Th. SCHEDULE ID PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) - CRR** WEIGHT/FT WEIGHT SIZE F f114 Il 1.660 11 1.442 II 9.91 11 1.81 I67fF11 2:518 ]L -6 1 1 [_1-112 1.900 J[ 1.682 7 7.76 1111 2.01i3if][ 3.053 11 61 Ll 2 IL 2.375 II 2.157 II 6.27 jl 2."l 4.223 lL_ 37 [2-1I2 II 1_.8_75____J [ 2'35 J[_4_.92_____J F__3_.53 lbs/ft1[ 5.893_____J F 30 1 3 ][ 350071L 3260 II 354 7l434lb7fti11 7957 11 19 i 4 [ 4 500 J [ 4 260 1 [ 150 = [5 6Ib/f-F1 j 1 f7961 F 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 ii 1.315 U 1.049 IL 1.00 II 1.68_lbs/ft 2.055 _j I 7.0 I 11/4 II 1.660 IF 1.380 _Jt 100 II 227 I159ftJ1 2918 =E 51 II 1900 II_1_610][1_00 j[2_72 I/ft]1 3.602 II 44 2 ]I _2.375 Il_2.067 II_1.001l3.66_I6?ifFI[_5.114 IE_30 1i/2* ___II_T75i]r.418 _IL_ 1.00 F-801 7.875= 3500 II_3068 II_100___lF758I6sIfiT1L_10783_IL [ 4* =[ —4.500 - Jl 4.026 U 1.00 18II 16.316I 19 I *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 4 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas 1X Masurt OH BIJU.. MOOSE TUB3 COMEAJ%W 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and 'adãrven products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. FireLock® Outlet-I ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'/4 through 76.1 mm132 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183, Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para___________ Location Date Approved Date www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV C III, ta uI i c' 10.52 1 IPSCARBON STEEL PIPE - HOLE CUT PRODUCTS Nominal Size inches/mm Hole Diameter + 0.0641.5 Dimensions - inches/millimeters - App rox. Weight Each Run X Branch FPTt -0.00/-0.0 - ,, 11/4 ½ 1 3/io 1.30 1.83 1,10 3.87 2.56 1.0 x 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ 1/2 1 3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1,40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1 3A6 1.64 2.30 1.22 408 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ 1 3A6 1.66 2.19 1.46 4.60 2.56 1.3 x 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 1 1A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 ½ 1/6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1 3A6 1.89 2.44 1.71 5,40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 M. 2.13 2.79 1,71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 1 3A6 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/~ 1 3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 3/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS ELI1 I-I 'f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of rui to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY, ALL RIGHTS RESERVED. 10.52 2 JhtauIicr REV C IF6 CARBON STEEL PIPE - HOLE CUT PRODUCTS PERFORMANCE - Run Size x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT I Inches/mm Feet/meters II•iiIi- .1. Hazen-Williams coefficient of friction is 120 FireLock® Outlet-T STYLE 922 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV C, 4tauiicr 1fl.2 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ,jl(t2IUIjc. 10.52 3355 REV 0 UPDATED 12/2009 vIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. U).52 II S P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC I12&3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - C@ uLISTED s 2551 1"- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSJJMSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPAI3 PIPE ROD IWl. 5W1.+250 UL TEST LOAD 1 3/8 3075 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 551 0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in u listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCOsvproducts have been, or are used. 1/08 Not less than 2 nominal width Wood Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless Wood Joist drill/driver. Saves time from traditional 1< methods. Iof Not less than 3 nominal thickness (2-1/2') (depth or side vertical member) Double Sheo Ceiling Reduces installation cost. Made in the U.S.A. 1/4" 8002957 GET 100 1/401" 210 (7116- DEB) 25 125 /I4 8003957 GOT 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GOT 300 1/4 x 3" 2060 (Fir) 25 125 I 3/8" 8006957 GOT 75 1/403/4" 564 (3/4" Ply) 25 125 2 (7/16088) 300 - 25 3(8 8007957 GET 10 1/4o 1 -- 125 3/8" 8008957 GET 20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST2O-SS Hl/4x2" 1760 (Fir) 850 275 125 I 3/8" 8009925 081 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Black Nut Driver Part#8113910 3/8 8010957 08130 - - 1/4x3" 2060 7(L 1500 1475 25 125 I 3/8" 8069925 GET 30-SS 1/4x3" 2060 (Fir) 25 125 3/8 8011925 GST40 1/4x4 2180 (Fir) 25 125 3/8" 8012925 GET 60 1/4x6" 2230 (Fir) 25 125 - 112" 8013925 051 2 1/4x2" 1760 (Fir) 25 125 I #14SWRed 1/2" 8014925 081 .5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 G13 1/4x3" 22761 Ir 2 125 I 1/2" 8016925 0814 1/4x4" 2180 (Fir) 25 125 1/2' 8017925 0516 1/4x6" 2230 (Fir) 25 125 - Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. "Accommodates up to 3 %" x 12 pitch roof. • Reduces installation cost. "Allows 17° deflection from vertical. "Made in the U.S.A. 111111111111111111t L 3/8' 8139957 SK-G10 1/4 x 2" 1257 (Fir) 1050 1475 25 125 125 1 -°" 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 j a #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Flour Joist Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. Not less than 2" nominal width / (1-1/2") up to 3-112" pipe; not less than 3" (2-112") nominal width 4" & 5 pipe I Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: This requirement ohs/li not apply to 2" or thicker nailing strips resting on top of steel teams. - #14 SW Red Nut Driver 1/4" 8018557 SWG 100 114x1" 622 (Fir) .15 125 1/4" 8019957 SWG 200 1/4 x 2 1725 (Fir) 25 125 E. 3/8". 8020957 SWG 10 1/4x1 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1I4x2" 1725 (Fir) 1050 25 125 8073925 SWG 20-SS 1/4 x 2 1725 (Fir) ilo 25 125 /.. 3/8" 8022925 SWG 25-380 3/8o 2-1/2" 2249 (Fir) 1500 25 125 I 318" 8023925! SWG 30 1/4x3 1884 (Fir) 25 125 Part #8114910 Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, -stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. isr gill ; Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. ~Ew ii1I•I SPECIAL NUT DRIVER SYSTEM: The not drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are inslalling into, continue drilling until not driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.