Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FPC2017-0111; Permit1J14RMAA18!'4__:L0J 'Ali (city of C arlsbad Print Date: 10/17/2024 Job Address: 2180 RUTHERFORD RD, CARLSBAD, CA 92008-7328 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120702500 Track #: Valuation: $73,625.33 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Permit No: FPC2017-0111 Status: Closed - Finaled Applied: 05/04/2017 Issued: 05/18/2017 Finaled Close Out: 04/07/2021 Final Inspection: INSPECTOR: Stowe, Daniel Fieri, Dominic Project Title: Description: CALLAWAY OGIO -SPRINKLER TI 7-100 (10 HEADS) / FPContractor: TITAN FIRE PROTECTION INC 1341 DISTRIBUTION WAY, #STE 14 VISTA, CA 92081-8843 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department. Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov OITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 1Pe2oi-- oR FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 17305 CALLAWAY - 0Gb 2180 Rutherford Road Carlsbad, CA 92008 V3801 and V3802 FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Standard and Quick Response Approvals/Listings: LPCB VZ-1 OT usnn 0832 104-la/02 See Victaulic Publication 10.01 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2'/13 mm adjustment to accommodate concealment needs. The "standard" design provides a consistent hemispherical spray pattern. The separate twc-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet mzny design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. \4taulicr 40.50 Technical Specifications: Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: 1/2/13 mm K-Factor: 5.6 Imp./8.1 SI.1 Nominal Thread Size: 1/2715 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinkler I FireLockw I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 JtauIicr victaulic.com I Sprinkler I FireLock I K5.6, V38 I Publication 40.50 Material Specifications: Accessories: Deflector: Bronze per UNS C22000 Installation Wrench: Cover Plate: Fusible solder El Concealed: V38-4 or V38-5 Bulb: Glass with glycerin solution. Sprinkler Finishes: LI Plain Brass (only) Bulb Nominal Diameter: LI Standard: 5,0 mm Cover Finishes: El Quick Response: 3,0 mm LI Chrome Plated LI White Painted3 Load Screw: Bronze per UNS C65100 LI Flat Black Painted3 Pip Cap: Bronze per UNS C65100 LI Custom Painted3 Spring: Stainless steel per UNS S30100 2 Teflon is registered trademark of Dupont Co UL Listed for corrosion resistance. Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 liliu Antaubc victaulic.com I Sprinkler I FireLocke I K5.6, V38 I Publication 40.50 Approval/Listings: Approvals/Listings Model V3801 V3802 Orifice Size (inches) 1/2" 1/2" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor SI.4 8.1 8.1 Response Standard 5mm bulb Quick' 3mm bulb Deflector Type Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C° V3801 V3802 135 Ff57 C 135 F/57 C 155 F/oS C 155 Ff68 C cULus 175 F/79 C 175 F/79 C 200 Ff93 C 200 Ff93 C 155 F/68 C4 FM5 NONE 175 F/79 C4 200 F/93 C4 135 F/57 C 135 F/57 C NYC/MEA5 #62-99-E 155 Ff68 C 155 F/68 C 175 Ff79 C 175 F/79 C 200 F/93 C 200 Ff93 C 135 F/57 C 135 F/57 C 155 F/68 C 155 F/68 C CSFM5 #7690-0531:112 175F/79C 175F/79C 200 F/93 C 200 Ff93 C 1550F/68C Sprinkler/138F/59C Cover 155°F/68°C Sprinkler/1 38°F/59C Cover LPCB 1 75Ff79°C Sprinkler/1 65°F/74°C Cover i 75F/79C Sprinkler/1 65F/74C Cover 200°F/930C Sprinkler/1 65°F/74°C Cover 200F/93C Sprinkler/1 65F/74°C Cover 135 F/57 C 135 F/57 C 155 F/68 C 155 Ff68 C VNIIPO 175 Ff79 C 175 Ff79 C 200 Ff93 C 200 Ff93 C 286 Ff141 C 286 Ff141 C CCCf ZSTDY NONE 155 Ff68 C For K-Factor when pressure is measured in Bar, multiply Si. units by 10.0. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 'j4'tauiic victaulic.com I Sprinkler I FireLockw I K5.6, V38,1 Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 25r/6S rum Max. Hole RV/60 Min. Hole 351s?80 mm 2ffrr7l rrttrt 2'A6"159 mm Ih"/38 W11 3 Typical Ceiling Tile rum torts Adjustment t 35.183mm Cover Plate Finished Surface Minimum Extension Maximum Extension 2'/51 rum Typical Ceiling Tile L Finished Surface Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory I I 4., 41, _ -- .. . 4 4 . 4 -- ___________,s. ,---- 4 S 4 4 — 4_ — — — — ------ -- -- -- --.. .. .4 '4 ---__ 2' 4' 6' 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7psi .... 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. Of victaulic.com 4 \JtaUI.c 3.0 8' 2.4 m 6 1.8 m 4, 1.2 m 2' 0.6 m 0 victaulic.com I Sprinkler I FireLocke I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -670F/-550C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature- F/C Temperature- F/C Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color I Identification Rating Allowed Ordinary A 135 F/57 C 1 100 F/38 C Orange A6 1358 57 100 57 Ordinary C 155 F/68 C 100 F/38 C Red D 7 165 16550 Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F/107 C Blue Extra High 8 K 360 F/182 C 300 F/149 C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C. 1 D For use with Standard or Quick Response Concealed Sprinkler 175F/79C or 200i/93C. 138F/59C per LPCB Note: Custom Finish - Customer to provide paint specification, al ow 4- 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent -V3801,V3802 V38-4 or V38-5 40.50 2658 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 \JtauIic. victaulic.com I Sprinkler I FireLocktm I K5.6, V38 I Publication 40.50 A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in POP format Victaulic reserves the right to change product specifications, designs and standard on our websve at www.vuctaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 6 \,/CtaUlic FireLock® V27, K5.6 \J C_ tauIic Models V2703, V2707, V2704, V2708 40.10 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp/S .1 SI.' Nominal Thread Size: ½ NPT/15 mm - :i V2703/V2704 V2707/V2708 V2707,V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /411 /19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location . Paragraph Contractor Approved Submitted By Date Date . victaulic.com I Sprinklers I FireLock® I K5.6,.V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 iCtaUIic - victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Installation Wrench: Bulb: Glass with glycerin solution Open End: V27 Bulb Nominal Diameter: El Recessed: V27-2 III Standard: 5.0 mm Sprinkler Finishes: El Quick Response: 3.0 mm El Plain Brass Load Screw: Bronze per UNS C65100 El Chrome plated Pip Cap: Bronze per UNS C65100 El White painted3 Spring: Beryllium nickel Black painted3 Seal: Teflon2 tape Custom painted3 Frame: Die cast brass 65-30 El Proprietary Nickel Teflon2 coating3 Lodgement Spring: Stainless steel per UNS S30200 D vC-250 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. i updated 07/2014 © 2014 Victaulic Company, All rights reserved. victaulic.com 2 \,,4tauIic victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Approvals/Listings: Model V ________ ________ APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/7" 1/2" 1/2 1/2" 1/7" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor SI.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard I Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/681C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F168°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/930C 175°F/79°C 286°F/141 °C 286°F/141 °C 286°F/1 41°C 286°F/141°C 286°F/141°C 200°F/930C 360°F/1820C 360°F/1820C 135°F/570C 1350F/57°C 135°F/57°C 1350F/57°C 155°F/680C 155°F/68°C 1350F/570C 155°F/68°C 155°F/68°C 135°F/57°C FM 1750F/790C 175°F/790C 155°F/68°C 175°F/79°C 1750F/79°C 155°F/680C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/930C 200°F/93°C 175°F179°C 286°F/141 °r 286°F/1 41°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/1 82°C 360°F/1 82°c 1350F/57°C 135°F/57°C 1350F/570C 135°F/570C 135°F/570C 155°F/68°C 155°F/680C 155°F/68°C 1550F/68°C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 175°F/79°C 175°F/791C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/930C 200°F/930C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/1410C 286°F/141°C 200°F/930C 360°F/1 82°C 360°F/1 82°C 1350F/570C 135°F/570C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 1750F/79°C 175°F/79°C 1750F/790C 175°F/79°C 1750F/79°C 155°F/68°C 200°F/93°( 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141 °C 286°F/i 41 °C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182'C 360°F/182°C 135°F/57°l: 155°F/68°L 135°F/57°C LPCB 175°F/79°C None None 1550F/68°C None None 200°F/93°C 175°F/79°C 2860F/141'C 200°F/93°C 360'F/1 82'C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 1550F/680C 1550F/680C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/680C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141 °C 286°F/141 °C 200°F/93°C 2867/141 oC 2867/141 OC 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 1550F/68"C 155°F/68°C None 1550F/68°C 155°F/68°C None 200°F/930C 200°F/93°C 200°F/93°C 200°F/930C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 1750F/79°C None None 175°F/790C None None 200°F/93°C 200°F/93°C 286°F/1 41 °C 2860F/1410C 360°F/1 82°C 135°F/57°C 155°F/68°C 1 55°F/68°C CE 175oF/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 86°F/141 °C 2 360°F/1 82°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with /2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 '..j4'tautic 17Ax/ 37 mm 2 60 1W! 2W! 41 mm 60 mm victaulic.com I Sprinklers I FireLock5 I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W160 mm Max. Hole 2/51 mm Mm. Hole• ±T1 30 mm 30 nm MAXIMUM RECESS 2'lAr"/ - 75 mm MAXIMUM EXTENSION ½" Adjustment Recessed - V2707, V2708 (drawing not to scale) 2"/51 mm 4W. HoleMm. Hole II1]l;ip1 15t/ 24 mm 18mm . A Typical Ceiling Tile A37 mm Finished Surface' 24 mm MAXIMUM RECESS 211V! - 75 mm MAXIMUM EXTENSION 3/4' Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulmc Company. All rights reserved. victaulic.com 4 . \ Al taUIic 17 mm 43 mn 10' 3.on, 8' 2,4,8 6' IA. 4, ten, 2' 0.6,8 victaulic.com I Sprinklers I FireLock.8 I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent uissriouuon l-'atserns - I rajecoory 2' 4' 6 8' 10' 12' 14' Mn, Sin, tOn, 2.4,8 3.081 3.7,8 4.3,,, Models V2703, V2704 K5.6 Standard Upright Distribution Patterns Trajectory 2' 4' 6' 8' 10' 12' 14' 16' 8.6,,, Sin, 1.0,,, 2.4,8 3.0n, 3.7,,, 4.3,,, 4.9,,, NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-welting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties, All patterns are symmetrical lathe centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 ,J Ac— tauIic 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLocke I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 1 C Red Intermediate E 175 F/79 C 150 Ff65 C Yellow Intermediate F 200 F/93 C 150 Ff65 C Green High J 286 1 C 225 F8/107 C Blue Extra High K 360 F/1 82 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703,V2704 Upright A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Ift Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. I, included with each shipment of Viclaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in POF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic fcr details. Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 Xj'ct9uIic '3 1G&SEDl ISTE Bull Moose Tube'sO Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube'se Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED AIPROVM (;]£fA NFPA --5- 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) O.D. (IN) I.D. (IN) CRR** WATER FILLED WEIGHT/FT WEIGHT BUNDLE SIZE 1 1.315 1.097 1527 141 lbs/ft 1.820 91 li/4r T°Th 1442 [9 91 [Th81fti/ft[2 5181[ 61' 11/2 1900 1.682 : 7 i6!?!LL053 61 -- 2.375 ' 2:1157-1 [627][2:64 IC#ft ][4223 2-1/2 r 2.87 5 2.635 492 353 Ibs/ftt 5 . 3[ 3500 jj 3260f :354ir34bs/ftTJc7957'r19 1 4 - 4500 4260 ' 250 562 l6s/ftT L 11796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1660 '[ 1.380- 227 16'W-1 2918 51 1 1/2 1.900 '11.610 - 1 00 - 272 lbs/ft 3.602 44 2: j[ 2375 '2O67LThu0 ][ 366I5/ftr 5114 [ 30 [ 2 1/2 2.875 2468 ' 100 5801bs/ft 7875 30 3500k 3068 100 758 iftIj[ 10783'[ 1 4 4500 4026 1 ioo lOsolb/ft 16316 19 'Only available in Casa Grande. AZ "Connosion Resistance Ratio per latest 01 Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q1 For Additional Information Contact (800) 325-4467 www.boIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,WA CasaGrandAZ DallasjX Masurti0H 63017 APPROV8I 1] AM- MUM _ NFPA' Bull Moose Tube'sa Eddythread 40® is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1 c®us LISTED ADVANTAGES OF BULL MOOSE TUBES EDDVTHREAD 40 Has a Corrosion Resistance Ratio of 1.0. Has a pressure rating of 300 psi. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 1ff MIC preventative coating. EDDVTHREAD 40 SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB/FT WEIGHT SIZE 1.295 1.083 1.00 1.461 1.860 70 [Thso i[ 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2375 2123 j[ jOo [33o8j[4.842 7L30 'Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q1 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIImoosetube.com 1819 Coa Road chesterfield MO 6era14 MO Kennt,WA Casa Grande, AZ Dallas, TX Masunt OH 63017 L Bull Moose Tube'sO EddyliteO is a lightwall threadable pipe manufactured in NPS 1" through 2". EddyliteO is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylitell is manufactured to meet the requirements of ASIM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVW (ONFSA NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 11 1.315 1137 0. 13 747 1 260 _"_____1.700 91 [11/4flfli66o][Th 482" lø 06""" 1[ 4 Th 1617""J[ 364 2 16 61 11/2 1.906- 1 712 0 12 i 453 -1.967 2.965 61 LT2 I1 2375 L JiiTL 1L1 t "Corrosion Resistance Ratio per latest UL Directory Iistinn PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q For Additional Information Contact (800) 325-4467 www.buHmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, Az Dallas, TX Masury.OH 63017 c®us LISTED APPROVW I] Art flfA_ NFPA' ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM A135 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry; preaction, and deluge type sprinkler systems. Lightweight — saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MlC preventative coating. NPS O.D. EDDY FLOWS EDDY FLOW" WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR PER FT. WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 [1 1Q rm 900 [i ns]f 2 2.375 2.203--^--'r 278 233o 3982 37 [21/2 'L 2875 11 2705 1[166f2809]['5299fl[ 30fl 3 3.500 3334 100 3361 j 7144 19 LJ9 J[ 4 310 l JEi J 19 J 'coosion Resistance Satin pee latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 clatlrson Road chesterfield MO Gerald, MO Kent WA Casa Grande,Z Dallas TX Masuty. OH 63017 7 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and fiielding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. Dull Moose Tube's Ultra Eddy is ADVANTAGES OF BULL MOOSE TUBES ULTRA EDDY I) a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit° Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddytm offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirenientfor dry systems. NPS O.D. ULTRA ULTRA EDDYtm WEIGHT WATER BUNDLE (IN) (IN) EDDY (ID) CRR°° PER Ft FILLED WT. SIZE 1 1.315 1.201 2.17 868 1.359 91 [1 1/4 1 660[1546 140 fl1 107]( 1 920[ !1i 1 1/2 1.900 1.786 111 1 )74 —2.360 61 E _2261 10O E 04 Jf 3344 '[37 Pressflt is a Registered Trademark of Viclaulic Company of America Corrosion Resistance Ratio per latest UI. Directory listing c®us LISTED APPRO983 omm NFPA -* PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q1 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa GrandAZ Dallas, TX Masoryt0H 63017 c®us LISTED APPROVUI I] 4LFA_ NFPA -- NPS(IN) 1 1-114 1-1/2 2 2-1/2 3 4 LnJ 1.315 1.660 1.900 2.375 0 (n)' 1.2011 1.546 1 786 2.261 UIJRAEDDY EmptyWeigh1ObIft) 0.868 1107 1.274 1604 WaerHIedWe4ght(Iblft 1.359--- 1.920 2360 3344 ___ 2.17 140 111 100 t 00(in)T I 1660 [1900 2375 2875 j[ 3500 14S00 i 1.530 j 1728 Jj 2203[ 2705 [ 3334i[ 43107 EWghtubJft) * 1.222 ir1 J 2 330 2.809 3.3M [ 4.968 EDDY FLOWS E2 019 t2 8601r 3 982 fl 2997[ 7 144'rll 2907 ______ cRTJ[51E 1 98[3 44J [2 78] 66 [Th oofloo7 1315 1660 1.900 2.P5 --r-2.875 3500 4500 E::IDcm)1 1097 1442 1682 2157 2635 3.260 4.260 SCHEDULE Li 9hiob/ft 1 410 1.810 2.090 2 640 3.530- 4.340 5620 a RIledWeght/b/ft) 1 820 2518 3053 4223 5893 7957 11 796 A 1527 991 776 627 1 492 354 - 250 I' 0D(in) 1315 1. 660-- r 19oofl37s ]E i[1 1[ 1482 j[ 1712 11T2 177j[ - k EDDYLITE [E5Weight(thtft)i1260[ 1 617[1 967 ]L26i7fl[ iii1[Tiii ii[T1 /ater-F/tied Weight (b/It) Th 700'7 [ 2 3647 [2 965 1r4 230] [ rir —i 013 'oos J[ LoTJLJ Jr T][ 1.295 1'650 1 900 2.375 - EDDYIHREAD T?in) j 1.083 1.418 1.645"-" 2.123 40 ei9ht (btft)j 1 461 2.070 2.547 3 308 iy eater 1/ed Weight (b/h) 1 860 2754 3.468 4842 RR. 100 100 100 100 r - — Dl r131sri66o'r1goo1cT37sncm87sr öoj[soo] 1(IJ[1 049 E-180 TJLi 610]L67]F2 469 ji7[a26j _5.6SCHEDULE r gtiThT8o[ 2 270E2 720E3 660 ro07[ Tol[10 iôöl - J [iL ió[i 1 A A For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@builrnoosetubecom O 1819 Clarkson Road - Chesterfield ' MO GerakiMO Kent.WA Casa GrandsAZ Daflas,TX Masurt0H 63017 9 PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRAEDDJ 0.868 91 1,659 1,896 1,975 CHEDuLE10J 1.410 91 2695 - 3079 3208 EoDYLITE:J' 1.260 91 ' 2408 2,752 2,867 EDDYTHREAD4O1 11.461 70 r 2148 2,454 2,557 UlE0ULE40 ---1680 70 2,470 2,822 2,940 mrRAEDDv]r 1 107 j[ &f JL 1418 1 621 1-.222---1 fl61[-j,5_5- 6 L --11,789=[ 1 864 SCHEDULE io[i 810 i6r )[2 319][2 650fl2 trEll 1617 i[611[2 071 J 2367 2.466- -2,070 W s11 t: 2 217 2 534 [2 639 SCHEDUIE'.,i 2270 iJfl 2,431 2778 1r2894 ULTRA EDDY 1 274 61 1 632 1,865 1,943 EDDYF1.06J 1,844 61 2362 2,700 2,812 2090 61 61 2,677 2,520 3,060 2,880 3,187 3,000 :EDDyLtTEJ 1.967 EDDYTHREW4O1 2.547 44 2,353 -- 2690 2802 CHEDULEÔ 2720 - 44 2513 2872 2,992 ULTRA EDDj 160]1 3ij[ 1 261r1 14 51 A ThDYFL0Wl1 2.330 3 1810 [2 069 J[ 2155 ThHEDULE10 2640 rir 2051 2344j[ 2442 1 3 308 30 2084 J[2 382j[ 2481 - 1 3.660 1[ 30 [ 23061126351[ 2745' - 2.809 - 1,770 1 2,022 2107 3.530 30 2224 2,542 2648 5.800 3654 4,176 4,350 7-1 r 1596 E44oj 19 [i 732 979J2O62 1 7.580 - 024 - '[ 3,456 3601 1 4.966 1,982 2,265 2,360 - 5.620 19 2,242 2,563 - -- 2,670 10.800 j - 4309 - 4925 - 5,130 F 928[Tj0 ] 1,951[ 2229 IE -i,322 T:1I4i 1L 2,846 2,9_65 NPS 1-1/4 1-1/2 2 c®us LISTED 2-112 AW 3 4 NFPA 10 * Only Available In Casa Grande AZ. ETWBE . LER PIPE SWAY BRACE C ]J BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@butlmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 3811 40 40 40 40 37 34 31 29 28 26 1 25 24 1 4 1544 1235 1 1012 1 867 1 7261 40 1 40 1 40 1 40 1 40 1 37 1 34 1 32 1 30 1 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 1 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 ( c®us LISTED ppRUvw no ONFM_ NFPA Q For Additional information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road ChesterfiektMO Gerald, MO Kent,WA Casa Grande. DaHa1)( MasurOH 63017 11 STYLE 922 The Style 922 outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2O68kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com vlcIAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vlc'rAuuc COMPANY. ALL RIGHTS RESERVED. REV_G Jt _au Iicr 10.52_i PS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 _________________________ I,nW,ir.,,pi.rTml1IITq.j.. __________ 1% ½ 13A6 1.30 1.83 1.10 3.87 2.56 1.0 32 35 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ~ 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 983 65.0 0.50 1 1 3/ 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ ½ 1 3/3 1.42 1 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 j, 0.54 14 1 3/3 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A3 1.64 2.30 1.22 4,08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 x 1h 53/3 1.66 2.19 1.46 4.60 2.56 1.3 50 15 302 422 556 371 1168 650 059 34 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 x '½ 1A3 1.91 2.44 1.71 1 5.40 2,56 1,6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1A6 1.89 2.44 1,71 5.40 2.56 1.6 20 30.2 48.0 62.0 43,4 137.2 65.0 0,73 1 . 1 ~/16 2.13 2.79 1.71 5.40 2.56 1.6 25.. 30.2 - 54.1 70.9 43.4 137.2 65.0 0.73 1h 76.1 mm X 1 1.91 2.44 1 1.71 5.50 2.56 1,6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 3/ 1.89 2.44' 1.71 ' 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1/3 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 1 70.9 1 43.4 j 139.7 65.0 0.80 FireLock® Outlet-T STYLE 922 DIMENSIONS p,I Ull II t Victaulic femae threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com - vIclAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. 2009 viclAuLic COMPANY. ALL RIGHTS RESERVED. . taul i c 10.52_2 . . . REVG 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Run Size u Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120), FT 40 25 2.6 50 25 21/2 x 1 65 25 )i.utipiuuuuuug Jr Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G A-c—ta-Ulicr 1O.52_3 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 Ac-ta U -1i d VIcTAuLIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings rspecfficatons i*_IIiI branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP DL Ductile iron castings conform to ASTM A536 us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME Bi 20 1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008, and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20t0 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 6& 320 650 300 Fig. 35E 3_900 Elbow C@US <~> APPROVED LISTED Size In Part Number _______ A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1 1.8 2-1/2 35E 3024 2.70 4 8 1 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1'1/4x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 11/4x1 35RE3012010 158 167 30 60 07 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 11/2 x 3/4 35RE3014006 1.52 1.75 25 50 07 1-112x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 tO 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 I Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 . 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number ________ A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T3010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 3513020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONALO • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com Size in Part Number A' in B in C in Packing Weight lb Inner Master 3/4x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1 26 1.26 1.36 30 60 0.6 1 xl/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1 x3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35R13010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x1/2x1-1/4 35R13012004012 1.75 1.53 175 25 50 0.9 1-1/4 x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x1-114 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 .1-114x1 x1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 35RT3012010010 1.58 1.50 1.69 20 40 0.9 -1/4xlx1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1f2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 - 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-112 35R13014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.80 12 24 1.2 1-1/2x1 x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 1, 3_ 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 11/2x1x1 1/4 35RT3014010012 182 167 188 12 24 12 1-1/2xlx1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-112x1-114 35RT3014012 1.82 182 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35R13014012006 152 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 c®US APPRJED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee - Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35B13006010 1.45 1.45 1,37 30 60 0.6 lx 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1-1/4xlxl-1/2 358T3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4 x2 35B13014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35HB3010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35H93014010 1.25 75 150 04 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 xl S 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 . 1.38 40 80 - 0.6 Fig. 355P3 - Square Head Plug Size in Part Number A. in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 JEE c(DUS <~> APPROVED A Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 -70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62. 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35RC3010004 169 80 160 0.3 1 x3/4 _35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2x 1 (riot hex) I 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smirhcooper.com Cells <~> APPROVED USTED Size in Part Number ______________ A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 . 35X 3020 2,25 6 12 2.8 Fig. 3513- Cross Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2x1 35RX3014010 1.80 1.65 12 - 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2. 2-1/2 350 3020 3503024 1.45 1.70 25 18 50 36 0.8 1.6 Fig. 35BC3 - Beam Size in Part Number A in Packing Weight lb I Inner I Master 3/8 35BC3003 0.75 1 100 200 0.3 1/2 35BC3004 F-075--1 80 160 0.5 I r -- SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 [INSTALLATION STEPS !A11lNTO WOOD & STEEL [INSTALLATION STEPS Ilii iiI.,INTO WOOD '& STEEL. Insert the appropriate nut driver into a 3/8'or 1/2° portable drill. Insert the SAMMYS5 into the #14 (black) nut diivar (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4' 3/8', 142'or metric all thread rod, bolt stock. (The 112' requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpulloul in puilin steel. I. Insert the appropriate nut driver into a 3/8'or 1/2' portable drill. Insert the SAMMYS into the #145W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. M-Offil _ lEiil'1ø INSTALLATION INSTRUCTIONS FOR CONCRETE INSTALLATION STEPS -j1LIN4TO CO4'CRETE:I Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Instakation note above). Insert the CSTscrew into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4', 3/8", 1/2", or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2' screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw LNSTALL'ATION STEPS -Ia. iIfINTO CONGRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/ rotary hammer drill set on impact mode. After pie-drilling has been completed, install the SLEEVE TOOL Over the bit (the bit should remain in the drill), and insert the #14.SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3./8"or metric all thread rod or boll stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. U1O SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYS FOR STEEL Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. ha eo demonswin a www.ftwbuildex.com 1/4" 8024957 DSTR 100 • 1/4-20 xl" TEKS 3 1510 1(20 ga.) .036*-20 ga 3116" 25 125 1 114 8025957 DST 100 1/414x I TEKS 3446(20ga) 038" 20 ga3/1625125J 114" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) .036-20 ga 3/18" 25 125 1/4 8027957 DST 200 1/4-14 x 2 TEKS3 446 (209a) 036 20ga 3/16 25 125] 1/4" 8030957 TEK500 12-24x1-1/2"TEKS5 3125 (3/16") .188"-3116" 112 25 125 3/8 8038957 DSTR I 1/4-20 xl TEKS 3 1510 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125] " 3/8" 8037957 DSTR 1-1/2 • 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .068"-16 ga. 1/2" 25 125 #14 Black 3/8" 8039957 DSTR5I6 5/16-18x1-1!4"TEKS3 1475 .036-20ga3 Nut 2200 (2093.) 1500 116" 25 125 J Part Driver 'io 3/8" 8040957 DST 10 1/4-14 xi" TEKS 3 446 (20 .03&-20 ga 3/16" 25 125 3/8" 8077925 DST 10-SS 1/4-14x1"TEKS3 .036-20 ga 3/16" 25 1251 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 .036-20 93 3/16" 25 125 3/8 8078925 DST 15-SS 1/4-14 xl 1/2 TEKS 3 446 (20 .036"-20 ga 3/16 25 125 ] 3/8" 8042957 DST 20 1/4-14x2TEKS3 446 (20 .036-20 ga 3/16" 25 125 3/8 8043957 DST 25 1/4-14 x 2-112 TEKS3 .036"-20446 (20 ga 3/16 25 125 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 .036-20 ga 3116" 25 125 1500 1475 .125"-1/8 3/16" 25 125 1 = . 318" 8046957 TEK 50 12-24x1-1/2" TEKS 5 3125 (3/16)1500 1475 .250"4/4" 1/2" 25 125 8031925 DST 2.01/4-14x2TEKS3 446 (20 .188"-3/16" 1/4" 25 125 1/2"8033925 DSTR 1.0_1/4-20x? TEKS 31510(20ga.) .036'-20 ga 3/16" 25 125 1/2" 8034925 DSTR 1/2" 8035925 DST 5.16 5/16-18x1-i/4" TEKS 3 1500 (3/16") .125-1/8 3/16" 25 125 #14d 8036925TEK5.012-24xl-1/2TEKS53125(3/16") .188-3/16 1/2"251J Part #8114910 lnc:udes retaining nut () Y SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins MADE 3 free. Installation is than complete. Warranty requires the use of the appropriate nut driver for installations. 74MMYS1 Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge — lIT thicknesses. dIft\ \ \ • A standard screwgun with a depth sensitive nosepiece should be used to r e qu ced install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Made in the U.S.A. WWWMWbuikieX.comj Ifl[.]1]If.iUcl1T12I? - 114° [ 1/4 - 8047957 SWD 100 8049957 SWDR 100 1/4-14 x 1° TEKS 3 1/4-20x 4 TEKS3 _i 1477 (16 ga.) 1900 (20 ga) .060-16 ga 036 20ga3/16_25125 1 3/16 25 I 125 3/8" 8050957 SWD 10 1/4-14 xl" TEKS 3 1477 (16 ga.) .060-16 ga 3/16° 25 125 8080925SWD10-SS 1/4-14 xj' TEKS 31477(16 ga) 3/8° 8051957 SWD 15 1/4-14x1-1/2'TEKS3 1477 (16 ga.) .060"-16 ga 3/16° 25 125 3/8 8052957 SWD 20 1/444 x T TEKS3 1477 (169 ___________ gIl 318' 8053957 SWD 516 5/16-18 x 1-1/4° TEKS 3 2480 (20 ga.) .036'-20 ga 3/16° 25 125 3/8 8055957 SWDR 1 ga) 1500 1475 .036-20 cia 3/16 25 125 1 #/4 SW Red Nut Dnver (> 3/6' 8054957 SWDR 1-1/2 • 12-24 x 1-1/2' TEKS 5 2375 (3/16) 1500 1475 .188-3/16" 1/2' 25 125 ['3/8 8056957 SWDR 516 5/16-1811/4 TEKS3 2480 (20 ga) 1500 1475 .036'-20 ga 3/16 25125] Part #8114910 — 3/8' includes retaining nut 8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16 .188-3116 1/2° 25 125 Eliminates distortion of threaded rod in sloped roof applications. "Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. Allows 17° deflection from vertical. Made in the U.S.A. I wwwMwbuildex.com #14 Black Nut Driver Part # 8113910 14 3/8° 8268957 SH-TEK50 12-24x1-314 uj 8270957 SH.TEK5O 12-4x1-/4 #14 SH Orange Nut Driver - Part #8273910 Does n1COrnp!y with ROHS requireirierds/mclude.s retaining nut 2368(1/2° steel Vertical) 1306(45° off Vertical) 1500 (Vertical) 2281 (3/16" HSS) 850(45° off Vertical) 1585 (3/16° HSS 45° off Vertical) 2368 (1/2° steel Vertical) 1306(45° off Vertical) 2281 (3/16° HSS) 1585(3/16° HSS 45° off Vertical) 4" 3/16° 1/2° 25 125 2-1/2' 3//6° 112" 25 125 S A 1111114 V X-P R E S 5) Installs into Metal Deck, Purlin, or Tubular Steel 4 T The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22ga. - 1/8'). Installs in seconds with Sammy X-Press It° Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. le. metal roof deck, tubular steel, or vapor baffler fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. c.Watc) a vJea 13vrww.i1wbui!dex.c) 114" 8181922 XP 200 Sammy 1146 (22 ga) 185 (Luminaire) .027 .125" 25 125 Metal Deck 16-Press 200 250 (Luminaire) .056" 850 (21YV Pipe) .02 940 (2 Pipe) 029" 3/8" 8150922 XP 20 Sammy .20 1146(22gal 185 (Luminalre) 250 (Lummaire) 1475 (4"Pipe) 104" .125" 25 125 Metal Deck X-Pre 283 (Conduit & Cable) .029" 1500(4" Pipe) 060" Sammy €> 3/8" 8153922 XP X Press 5 1783 (l6ga) 250 (Luminaire) :056: 1475 (4" Pipe) 125" 25 125 Purl/n 416 (Conduit & Cable) .059" r I Pre-Pour Structural Corrcrete@ 3000 Metal Deck I 3/8' 8150922 XP 20 Sammy1146(229a) 850(2%Pipe) 25 125 X-Press 20L L Metal Deck Post-Pour Range llLWC:535PCFQbs/tfl Pre-Pour Structural Concrete @3000 psi Post-Pour Range II LWC 35 PCF (lbs/tO') The -SidewlnderX-Press expands to provide Less jobsite material needed. horizontal attachment in: -16 ga -3/16" steel - purlin, tubular steel. No retaining nut required. "Installs in seconds with Sammy X-Press It° Tool, "Provides design flexibility. saving time & installation costs. "Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; le. metal roof deck, tubular steel, or vapor barrier fabric. l4chavideamons)stuna)'t • wwwllwbulldexcomJ - --- z Sidewinder . 3/8 8293957 SWXP3S X-Press 35 1798 (16 gal raj Lur,unaue) 059 125 25 125 Purlrn 416(Ci&C W V7,W-11 (SWXP) INNERM5AY1S The Swivel K-Press allows you to hang plumb in extreme roof pitches: - 89° in z-pudin - 450 in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press le Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Waitha *eo drnonstraaT\ www.ilwbulldex.comJ . 170 Vertical Luminaire) 4. > 3/8 8294922 SXP 20 Swivel 1061(22 5 im) 029" 635 (2"Pipe) .029' .125" 25 125 Metal Deck x Vert) 283 Vertical (Conduit & Cable) 1250(3-1/2° Pipe) Swivel 1675 (16 ga 250 Vertical (Luminaire) 3)9" 8295922 SXP 35 X-Press 1558 Off Vert) 500 Vertical (Conduit& Cable) .059 635 (2° Pipe) 029° .125° 25 125 Purlin 333 @89° (Conduit & Cable) Swivel 1/2 8272957 SXP 2.0 1061 (22 ga Vert) 027° 125 25 125 Metal Deck 1/2° 8271957 SXP 3.5 Swivel 1675(l6gaVert) X-Press3.5 1558(89° Off Vert) .060° .125° 25 125 Puttin The SammyX-Press expands to provide direct vertical attachment in: ui J metal deck (22-16 gauge) Z-pudin (18-16 gauge) Made / .; . •'- t J 1 I _____________ Part Number Model Description City 8194910 UXPFT Universal X Press It Tool 1 1 8152910 XPDB 25/84° Drill Bit 1 loot Includes: Sleev€, Bit Receiver Hex Wrench, and 25/84° Drill Bit 1 85 .027" Vertical 250 .035" 185 .027" Vertical -- 250 .035" 185 .027' Vertical 250 Vertical 170 .027" 450 80 .027" Vertical 250 .060" 90° 80 .060" Horizontal 80 .060" 8153922 XP 35 3/8" [ 8181922 XP 200 1/4" 8294922 SXP 20 3/8' EI 922 SXP 35 3/8' 8293957 SWXP 35 3/8" APPROVALS I 8020957 SWG 10 3/8" Horizontal _______ CPVC 1-1/2" 300 1-1/2" - 1.08957 20 Z erbcal -1 IT 2 "ZL 1-1/2"j 8068925 GST2O-SS 318' Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4' 1475 1-1/2" 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-3803/8 Horizontal 3-1/24 1500 11/2 8021957 SWG 20 3/8" Horizontal - 2-1/2"-3"°" 1050 1-1/2" 8073925 SWG2OSS 3/8 onzontal Ti 850 11/2 1 8269957 St1-GSTICST2O 3/8" 45° Angle off Vertical 2-1/2" 850 1-1/2" L8269957 SH-GST/CST2O3/& - 45° Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17"Angleofi Vertical 1050 1-112" 4" 1475 1-1/2" I !0!!7 DSTR 1__.!L!__,._Y L_. i05. i 8037957 DSTR 1-1/2 3/8" Vertical 1500 .035" 4' 1475 .1050 [8o399s7DSTRs Vertical'-_ 400 037 41475 105 3 8045957 DST 516 3/8" Vertical 4" 1500 .188" - 4" 1475 .188' f'6957 TE 3/8' Vertical 4_ 1500 250 4 1475 188 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" ETSWDR 516 3/8 -Horizontal 4 1500 037 4 1475 060 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" F"37957 SH DSTR13/8 17 Angle off Vertical 4 1500 035 4 1475 1051 8268957 SH-TEK 50 3/8 Vertical 2-1/2" 850 70°Angleoff Vertical 4" 1500 2" 940 I 8150922 XP 20 = 3/8" Vertical 2-1/2" 850 .027" 5 1475 _______ O5j 8153922 XP 35 3/8" Vertical 4" 1500 .060" [i94922 SXP 20 3/8" VesicIorupta45°2 750 27" 2" 8295922 SXP 35 3/8" Vertical or up to 89" 3-1/2" 1250 .060' 2" 635 .029" - r 8293957 SWXP35 3/8" Horizontal 31 2 1250 .060" L.805995L CST 20 3/8' Vertical 4' 1475_ 3000 8061957 SWC2O 3/8' Horizontal 4' 1475 3000 8150922 XP2O 3/8 Vertical 21/2 850 Pre-Pour Structural@3000pm_____ 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC :5 35 PCF (lbs/113) .027" ----Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8' Vertical 500 .060" Max 4 trade size ENT & 6 trade sze RMC, IMC, and rigid PVC conduit [8294922 SXP 203!8 Vertical 283 027" - Max4 trade size EMT RMC and INC &5trade size ngid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit [i5T Pi3I8 Horizontal 500 .060'_Max 4 trade size EMT &6 trade sze RMC, INC and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies WI NEC Standards GaugfN_o._ ________ 22ga Ogaj8ga Nominal Decimal Equivalent .030" .036" .048" 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe aloe in wood timber or joist allowed by UL is 4' "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1t2" ga. 14 p. 12 ga. 1I8" 3116" 1I4 .060" .075" .105" .125' .188" .250" UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118°. Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. SammysO Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.corn Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvlronmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite JoistlTruss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole !1lISize GST 2O .182" 118° GST 25-380 .280° 7132" SWG 20 .182" 1/8° SWG 25-380 .280' 7132° To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling NFPAINEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com ALsoLrnw.smnMDcAaEKAflgqE am, Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products EM Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information L1 Listings/Approvals - KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACl 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of AOl 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor IN— APPOR Indenendent code evaluation IBC®/ IRC®2015 IBC®/ IRC® 2012 IBC®/ IRC®2009 IBC®/IRCO 2006 -. _••__ Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 I Hilti (canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 319 Mechanical Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications 1,2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbs in. 1/4 Nominal embedment hnom in. 1-5/8 2-1/2 Effective embedment he1 in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T., ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 Tnn is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3,4.5 Nominal Nominal Tension- qN Shear - anchor embed. f', = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f' = 2,500 psi f' = 3,000 psi f', = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 1/4 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' .2,3,1,5 Nominal Nominal Tension - Shear - anchor embed. f' = 2,500 psi f' = 3,000 psi f', = 4,000 psi f' = 6,000 psi f', = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 1/4 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A = 0.60 Tabular values are for static loads Only. Seismic design is not permitted for uncracked Concrete. For seismic tension loads, multiply cracked Concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a5 = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear' Seismic shear' diameter thread diameter cpV in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 UNC (16.4) (3.6) (1.6) 1/4 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension (ON. = 4AOaNf, as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V <0.6A 5 f,,, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with (PV :5 4P 0.60 A,5 f,, as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. - ---.---- - -. =-=:- 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espatol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 5= Mechanical Anchoring Systems r 4D 111IIIIII KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 uncracked concrete I RN 'AV fRy I RV 'NV Embedment in. 1-5/8 2-1/2 1-5/8 2-/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a )j$ 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 _______ 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a lb .. E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a d 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 ca 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 0.98 0.83 0.72 0.93 ) 5-1/2 (140) 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CU 10 (254) 0.89 CL 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concret&' Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 cracked concrete f I RN JAy .fRV .fRV IHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-112 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a (15 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 0 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a oc 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 ca 4-1/2 (1 14) _______ 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 a ma 5-1/2 (140) 0.98 0.83 0.72 0.93 6(152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 ca 8(203) 0.98 0.82 9 (229) 1.00 0.86 10(254) 0.90 1 11(279) 0.94 1 12(305) 0.98 1 14(356) 1.00 1 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, I NV assumes an influence of a nearby edge. If no edge exists, then I NV = f AN 4 Concrete thickness reduction factor in shear, f, assumes ar, influence of a nearby edge. If no edge exists, then I NV = 1.0. ELJ If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espaCol 1 -800-879-5000 I Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 Mechanical Anchoring Systems - 3.3.7 kWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - 4N Shear - Tension - 4N Shear - anchor thread embed. f'0= 3,000 psi f= 4,000 psi f= 3,000 psi f= 4,000 psi f'= 3,000 psi f= 4,000 psi f= 3,000 Ps = 4,000 Ps diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"2'3'4'6'7'8 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - _pN Shear - _pV, Tension -cpN Shear - _pV anchor thread embed. f'= 3,000 Ps f= 4,000 psi f= 3,000 psi f'= 4,000 Ps f= 3,000 ID f'= 4,000 f= 3,000 psi f= 4,000 Ps diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) 1 (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) 1 (4.1) 1 (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h0,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0Nw, = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - ;,, = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. - 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) T.rp. 1 -800-363-4458 I www,hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2—Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm. 3/4" Mm. 3.000 psi sand-lightweight or normal-weight concrete L... Y6%b LLU - Liy55 Upper izC Mi flute n. 4-1/2" Minimum (typical) 20 gauge - - L \__ steel deck Mm 4 1/2 Anchor Flute edge Lower (typical)I flute Min. 1-1/4"'-__--•- Mm. 12' (typical) (ridge) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactoredi by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor',' Nominal Internal anchor thread Tensile3 Shear4 Shear' diameter diameter N, V in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N PS f R as noted in GSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V < 4 0.6 f,, R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V.,q < A 5 p 0.6 f, A as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. CO CO Hilti, Inc. (US) 1 -800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 Mechanical Anchoring Systems II11 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 H Design parameter Symbol Units Nominal anchor diameter Ref 1/4 - P23.3-14 Anchor O.D. d in. 1/4 (mm) (6.4) in. 1.18 1.92 Effective embedment h el (mm) (30) (49) Minimum nominal embedment2 h00 in. 1-5/8 2-1/2 (mm) (41) (64) in. 3-1/4 4-1/8 Minimum concrete thickness (mm) (83) (105) in. 2.00 2.78 Critical edge distance Cac (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 (mm) (38) I n. 1.50 Minimum edge distance Cmin (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 I 2-7/8 (mm) (51) I (73) Minimum specified ultimate strength uta psi 125,000 (N/mm') (862) W 0.045 Effective tensile stress area A N (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 0.5.3 lb 3,370 Factored steel resistance in tension N, D.6.1.2 (kN) (15.0) lb 750 Factored steel resistance in shear V D.7.1.2 1/4-20 UNC internal thread sar (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V51 (kN) (1.5) lb 725 Factored steel resistance in shear V D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V weq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k cr - 7 0.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 c,N - 1.0 D.6.2.6 Anchor category - - 3 1 D.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R 0.75 1.00 0.5.3 (c) Condition B5 lb 665 1,645 Factored pullout resistance in 20 MPa uncracked concrete6 N Pr, oncr D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete6 Nprçr lb 340 815 D.6.3.2 (kN) (1.5) (3.6) lb 275 815 Factored seismic pullout resistance in 20 MPa cracked concrete6 N 0.6.3.2 " (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex a See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, 4N = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k) or uncracked concrete (k0 ) must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA P23.3-14 section 0.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qj = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espahol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Anchoring Systems Fr 117- KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWlK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2,3,4,5 Nominal Tension - N Shear - V f' = 20 MPa f', = 25 MPa 1' 30 MPa f = 40 MPa P. = 20 MPa 1',, = 25 MPa f = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 .805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1/4 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concrete 1,2,3,4,5 Nominal Tension - N Shear - V IC = 20 MPa f = 25 MPa f' = 30 MPa f' = 40 MPa IC = 20 MPa IC = 25 MPa IC = 30 MPa f, = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) 1 (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by AC as follows: for sand-lightweight, A = 0.68; for all-lightweight, A = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. ~331.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca i Anchor Fastening Technical Guide 2016 325 Mechanical Anchoring Systems 11111_T1IiIiIcIii 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 iii Installation in lower flute Installation inupper flute Nominal Nominal iternal Nominal Tension - Nr Shear - V Tension - Nr Shear - Vr anchor thread embed. f' = 20 MPa f' = 30 MPa f' = 20 MPa f', = 30 MPa f' = 20 MPa I', = 30 MPa IC = 20 MPa f' = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/ UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5,6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Nr Shear - Vr Tension - N, Shear - Vr anchor thread embed. I'. = 20 MPa I'. = 30 MPa I = 20 MPa I' = 30 MPa I', = 20 MPa I. = 30 MPa f'c = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 / UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) 1 (2.8) (3.4) 1 1 See Section 3.1.8.6 to convert design strength value to ASO value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hnorn (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,!C = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 33.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 U 1-5/8NC 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.37 Table 16 - Hilti KWlK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Mm. effective embedment h ef in. Allowable load' Ultimate load Tension lb Shear lb45 Tension lb Shear lb45 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-I Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3- Installation of Hilti KWlK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7 I 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available On request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information" Internal thread Internal thread Description diameter - length KH-EZ 1/4x1-5/811/4 1/4 3/8 KH-EZ 1/4x2-1/2 11/4 1/4 - - 3/8 KH-EZ 1/4x1-5/813/8 3/8 7/16 KH-EZ 1/4x2-1/213/8 - 3/8 - 7/16 1 All dimensions in inches. Hole Minimum diameter embedment Qty / box 1/4 1-5/8 100 1/4 2-1/2 100 1/4 1-5/8 100 1/4 2-1/2 100 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./1100 3/8 16 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 11/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./1100 3/8 1A6 11/4 1 7/16 1 610 28 1/2 1½ 1¼ 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4M and 11/411 Throat Openings Component of State of California OSHPD Approved c YL us LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD Droiects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 * Max. loads for clamp with set screw in up or down position. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 II CUSTOMER SERVICE • 800.786.5266 www.tolco.com B-Line Fig. 25- Surge Restrainer c®Us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Size Range - Secures 3/8' thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Component of 5t ate of California OSHPD Approved c@ US LISTED Seismic Restraints System Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number .44:. Fig. 99 - All Thread Rod Cut to Length Fig. 100- All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. - CORONA, CA 92819. PH: 951.131.5599 • FAX: 951.131.0330 CUSTOMER SERVICE • 800.186.5266 www.toko.com Fig. 200-1 to 200-2 \ / B A Fig. 200_1/2. 200-I4 Fig. 200_2112 to 200-8 Fig. 200F Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) USTED C, US Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 0/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals; Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Part No. Pipe Size Rod Size A /1-16 ' 31/ B Approx.Wt./1100 (5.0 200-/4 3/4' (20) /8'-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) /8-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200-1I4 11/4° (32) /8'-16 33/4' (94.0) 2/8' (73.0) 13 (5.9) 200_11/2 11/2° (40) /8"-16 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200-2 2' (50) /8"-16 41/2° (114.3) 3" (76.3) 15 (6.9) 200_21/2 21/2' (65) 1 3/8"-16 5I8" (142.9) 41/6' (104.7) 27 (12.3) 200-3 3 (75) /8'-16 5/8' (149.1) 4° (101.6) 29 (13.3) 200-3I2 31/2' (90) /8"-16 7I8" (187.3) 51/4 (133.3) 34 (15.6) 200-4 4' (100) /8-16 7I8" (187.3) 5' (127.0) 35 (16.0) 200-5 511 (125) 1/2"13 9118" (231.8) 61/4' (158.7) 66 (30.2) 200-6 6.. (150) 1/2°..13 101/8" (257.2) 63/4' (171.4) 73 (33.4) 200-8 8' (200) 1/2"13 131/8 ' (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 00 COOPER B-Line ®TOLCO C&S Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 0/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe €1. types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. '.. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) Fl 2002 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-11 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel / materials will be supplied with (2) hex nuts / in place of a knurl nut. f' Order By Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200-1/7. 200-/4 Fig. 200-21I2 to 200-8 Pipe Part No. I 200M8-1/2 1/2 Size RodlTI'iIr4: A Iin. ._____OillD I (15) M8 31/8 (79.4) in. .___1___ 2/8 B Approx. Wt./1100 ' (66.7) 11 (5.0) 200M10-1/2 1/2 (15) M10 31/8' (79.4) 2/8' (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8 (79.4) 21/2' (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8 (79.4) 21/2 (63.5) 11 (5.0) 2001VI8-1 1" (25) M8 3/8' (85.7) 2/8' (66.7) 12 (5.5) 200M1-1 1" (25) MiO 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4' (32) M8 33/4 (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4' (32) M10 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2/8 (73.0) 14 (6.4) 200M10-1112 11/2" (40) M10 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200M8-2 2' (50) M8 41/2 (114.3) 3" (76.3) 15 (6.9) 200M10-2 2'. (50) M10 41/2 (114.3) 3 (76.3) 15 (6.9) 200M-21/2 21/2' (65) M10 5/8' (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3 (75) M10 5/8 (149.1) 4' (101.6) 29 (13.3) 200M-3112 31/2' (90) M10 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) M10 7/8" (187.3) 5" (127.0) 35 (16.0) 200M-5 (125) M12 91/8 ' (231.8) 61/4' (158.7) 66 (30.2) 200M-6 (150) M12 101/8 ' (257.2) 63/4 ' (171.4) 73 (33.4) 200M-8 8' (200) M12 13/8' (333.4) 8/4' (222.2) 136 (62.3) Al dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. p...- COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /"-16 or 1/213 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. .. 162*61 iiiiiiiiiiii c®us LISTEO 0H-2-/8 Pipe Size 2" (50) Rod Size /8"-16 A 4911 ,3T81748 B I Approx. }Wt./100 200H-2-1/2 (50) 1/2"..13 423/32' (119.8) 33/8' (85.7) 45 (20.4) 200H-21/2-3/8 21/2" (65) I8"-16 5/16' (134.9) 323/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4" (146.0) 3/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"13 5/8" (148.1) 3/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H 4 4 (100) 1/2"-13 71/32 (1786) 419/32 (11167) 73 (331) ° Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PW COOPER B-Line F P P I Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ" System Compatible Program* Certified to NSF/ANS/Std 61 -G FBC5. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPP, LubeFite are registered trademarks of Fire Protection Products, Inc. LA FGG/BM/CZ", Blaze-Master,", HowGuard Gold" and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread - sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique 1T pineAt' blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FB SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX+1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5g1. 55 gI. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu LA MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPPPTh, LubeF0 are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMastef3, HowGuard Golda and Co,zan® are registered trademarks of Noveon IP Holdings Corp. Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary ThieFiF lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. L - Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBCV; SYSTEM COMPATIBLE *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 UONSHEAD AVE CAIRLSBAD, CA 92010 TEL +1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil, absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEM TREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300. © 2013 Fire Protection Products, Inc. FPPP, ThreadFit5 are registered trademarks of Fire Protection Products, Inc.