HomeMy WebLinkAbout1800 ASTON AVE; 100; FPC2018-0310; Permit4City of Carlsbad Print Date: 10/17/2024 Job Address: 1800 ASTON AVE, # 100, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121206100 Track 1t: Valuation: $671,650.91 Lot U: Occupancy Group: Project #: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check #: Permit No: FPC2018-0310 Status: Closed - Finaled Applied: 09/17/2018 Issued: 11/07/2018 Finaled Close Out: 04/07/2021 Final Inspection: INSPECTOR: Project Title: Description: BUZZTIME- FIRE ALARM T.I. INSTALLATION OF NEW ZONE EXPANDERS FOR MONITORING OF DUCT SMOKE DETECTORS Applicant: ADT COMMERCIAL JOHN STASUKEVICH 10107 CARROLL CANYON RD SAN DIEGO, CA 92131-1109 (760) 535-0045 - FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FPC20I8-0310 1800 ASTON AVE #100 BUZZTIME- FIRE ALARM T.I. INSTALLATION OF NEW ZONE EXPANDERS FOR MONITORING OF DUCT SMOKE - DETECTORS 2121206100 E DEPARTMENT 9/17/2018 N DIVISION FPC20I 8-0310 ! MY AVENUE )CA 92008 760402-4665 RECEIVED SEP 172018 CARLSBAD FIRE DEPARTMENT Construction Permit Application Form Name of Project: SUZ -TzT/'-1E' Address of job site: /OO 145 7-0/V /1Y,N(€ Suite# /ct) Building Permit No: CB ( I'bC ,Lij )o7 Project I.D.: Contractor Information Company Name /P Hi"< /2r/E ECitz?( Address 9zc' S. ,q/VD,'ZEASEM Di'?. STE. 'o2 City EcofVPPO State CJ4 Zip 90079 Phone: 760-Z.33 —9797 Fax: 7 go - E-Mail: Contractor License Class and Number C-0/c-16 713059 Exp. Date: I'/c30/a018' Do you currently have a business license on file with the Cxçofcrlsbad? or No No: 3Los 61S Name: 3i,v .5t.)/V1JC/l Signature: Date: Submit plans and completed permit application to: CARLSBAD FIRE PREVENTION 1635 FARADAY AVENUE CARLSBAD, CA 92008-7314 (760) 602-4665 Fax: (760) 602-8561 firemail@carlsbadca.gov Office Hours are: M-TH 7:30 a.m. - 5:30 p.m. PST FRI 8:00 a.m. - 5:00 p.m. PST To Schedule an Inspection: For inspections ONLY, please call (760) 602-4660, a minimum of two days in advance. Calls will be returned by the end of the next business day. Inspection Hours are: 6:30 AM - 5:00 PM Re-inspection fees and Hydrant Flow Test fees must be paid at the above address prior to receiving an inspection. Inspection Personnel are prohibited by law from accepting payments in the field. All payments must be made at the address above. Plan Check status Inquiries: Allow at least 10 business days for plan review comments and/or approval. This office will contact you when the plans are approved I disapproved. Please include a self-addressed stamped envelope for mail return of plans. If after 10 business days you have not received a communication from our office, you may contact us at 760-602-4665, by FAX to 760-602-8561 or e-mail us at: firemail@carlsbadca.gov Revised 9/3/2015 FPC20I8-0310 1800 ASTON AVE #100 BUZZTIME- FIRE ALARM T.I. INSTALLATION OF NEW ZONE EXPANDERS FOR MONITORING OF DUCT SMOKE DETECTORS 2121206100 9/17/2018 FPC20I8-0310 FIRE ALARM SYSTEM TENANT IMPROVEMENT SUBMITTAL For BUZZTIME 1800 ASTON AVENUE, SUITE 100, CARLSBAD, CA 92008 Submitted By: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 PROJECT INFORMATION SHEET PERMIT NUMBER: fP2oIgo3so INSTALLING CONTRACTOR: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 CONTRACTORS LICENSE: C-10/C-16 #713099, 11/30/18 PROJECT MANAGER: John Stasukevich PROJECT NAME: BUZZTIME PROJECT ADDRESS: 1800 ASTON AVENUE, SUITE 100, CARLSBAD, CA 92008 SCOPE OF WORK: FIRE ALARM SYSTEM TENANT IMPROVEMENT October 25, 2018 Re: Buzztime 1800 Aston Avenue, Suite 100, Carlsbad, CA 92008 Fire Alarm System - Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinklered. QTY- MODEL NO. DESCRIPTION C.S.F.M. 18 711 Single Input Monitor Module 7165-1157:0135 1 BPS 1OA Remote Booster Power Supply 7300-1657:0229 14 GCF-VM Strobe Only, Ceiling Mount 7125-1657:0219 6 G1F-VM Strobe Only, Wall Mount 7125-1657:0218 6 G1F-HDVM Horn Strobe, Wall Mount 7125-1657:0202 6 GCF-HDVM Horn Strobe, Ceiling Mount 7125-1657:0202 Notes: 1. The existing Fire Alarm Control Panel is manufactured by DMP and is compatible with all new devices. Respectfully Submitted, RED HAWK FIRE & SECURITY SECURITY SIGNALING LISTED Simple Expansion Solutions Expand your DMP panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, glassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 modules. SII9GELE AN D flt4JULTIIPJLE POUT - .......... ZONE EXPANSION NODULE FEATURES Provides Class B zones for burglary and fire • Proven design ensures stability and performance Compatible with DMP Panels that allow zone expansion • Data LED on zone expander indicates good panel Suitable for mounting near protection devices communication Connect devices using 4-wire bus Durable and attractive plastic or metal housing Easily mount attractive cases on wall or 3-gang bcx Low current draw Compatible with all panel zone types • Can be powered from panel or auxiliary power supply Easy connection to 4-Wire Keypad or LX Bus USE ON THE DMP LX-BUSTm The modules can be used on the LX-Bus of DMP Panels. The modules connect to the 4-wire bus and use only one zone address. To assign an additional zone expander use the next available zone address. CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, and 715-16 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the covers go on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708 and 710 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1 R Receivers. 708 BUS EXTENDER MODULES The 708 Bus Extender Modules allow you to increase the length of wire used to run an LX-Bus or keypad bus by a maximum of 4,000 feet, while providing immunity to noise on the wires. The 708 Bus Extenders are received from the factory as a pair of modules that connect between the panel and LX-Bus or keypad bus devices. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710 BUS SPLITTER! REPEATER MODULE The 710 Bus Splitter/Repeater Module allows you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710 Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! 710 As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional 12 VDC LX- Bus or keypad bus circuits. This makes the 710 module an excellent junction box when terminating multiple LX-Bus/ keypad bus runs at one location. As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 7I28 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included sI sc-a -o- 7141715 ZONE EXPANDERS 714-8,714-16,71 S-8, AND 714-8, 714-16, 715-8, AND The 714 contains four Class B burglary 715-16 DESCRIPTION 715-16 FEATURES zones and is suitable for use with burglary The expanders are housed in a Model 8 or 16 protection zones per and fire devices that are normally opened 340 locking metal enclosure suitable expander or normally closed. Individual zones are for mounting in a remote location. Durable metal enclosure housing supervised with 1k Ohm EOL resistors and Each expander provides screw terminal with lock and key can be programmed with any burglary or strips for zone inputs and data bus Individual screw terminals fire zone type. connections, a two position jumper to accommodate 14 to 22 gauge wire oesignae connection to the Keypad ous for easy connection or the LX-Bus, and an LED to indicate • Suitable for mounting in a remote communication with the panel. Separate location zone End-of-Line resistors are included with each expander. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 720T Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 720T. 714/715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-81714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8I71S-I 6 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. ill DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire Keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. DFEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing Digital Monitoring Proth,cto J!i P ) FMI i ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-HolePlastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC All DMP 12 VDC 710 N/A N/A Yes Yes 712-8 Dip Switch 8 Yes No 12 VDC XT Series and XR100/XR500 Series 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure MODULE SPECIFICATIONS 714/715 SPECIFICATIONS 708 SPECIFICATIONS (NON-UL) Operating Voltage 8.8 to 15.0 VDC Operating Voltage 8.8 to 15.0 VDC Operating Current Operating Current 20mA Per Pair 714 Average 7mA + 1.6mA per zone Dimensions 4.5" X 2.75" X 1.75" Alarm 7mA+ 2mA per zone Maximum Distance 4,000 feet between the two 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke 708 Modules Alarm 7mA + 58mA per shorted zone + 0.1 per 710 SPECIFICATIONS 2-wire smoke + 30mA per smoke in alarm Operating Voltage 8.8 to 15.0 VDC Dimensions 4.5" X 2.75" X 1.75" Operating Current 7148, 71416, 71 S8, AND 715-16 SPECIFICATIONS 710 30mA Operating Voltage 8.8 to 15.0 VDC Dimensions 4,5" X 2.75" X 1.75" Operating Current Distance 2,500 feet (one module), 714-8/16 15,000 feet maximum Average 20mA + 1.6mA per zone C7iIDSPECIFICATIONS Alarm 20mA + 2mA per zone Operating Voltage 8.8 to 15.0 VDC 715-8/16 ®perating'Gurrent Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Average limA + 1.6mA per active zone Alarm 20mA + 58mA per shorted zone + 0.1 per Alarm 11 mA + 2mA per zone in alarm 2-wire smoke + 30mA per smoke in alarm Zone VoLtage 5 VDC (1 .6mA across EOL) Enclosure 20-Gauge cold-rolled steel Dimensions 4.5" X 2.75" X 1.75" Dimensions 12.5" W x 11.5" H x 3.5" D 714-8/-16 Color Gray 712-8 SPECIFICATIONS 715-8/-16 Color Red Operating Voltage 8.8 to 15.0 VDC Current Draw 1 7mA + 1 .6mA per active zone LISTINGS AND APPROVALS 17mA + 2mA per zone in alarm Refer to the appropriate panel programming and installation guide Dimensions 4.5" H 2.5" W for specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshall (CSFM) New York City (FDNY COA #6055) (711, 714, 715 only) Underwriters Laboratories (UL) Listed For additional information, access www.dmp.com and select Compliance. now [ThmJ 2500 North Partnership Boulevard Ttnab Springfield, Missouri 65803-8877 W191t.1 MonW-ing Productm IF Contents ZONE EXPANSION MODULE FEATURES 1 USE ON THE DMP LX-BUS 2 CONNECT TO KEYPAD BUS 2 SIMPLE ADDRESSING 2 EASY INSTALLATION 2 ZONE PROGRAMMING 2 708 BUS EXTENDER MODULES 2 710/710F BUS SPLITTER/REPEATER MODULES 2 712-8 ZONE EXPANSION MODULE 2 712-8 FEATURES 2 714/715 ZONE EXPANDERS 3 714-8, 714-16, 715-8, AND715-16 DESCRIPTION 3 725 24 VDC EXPANSIONMODULE 3 711 DESCRIPTION 3 711 FEATURES 3 ZONE EXPANSION MODULE COMPARISON CHART 4 MODULE SPECIFICATIONS 4 LISTINGS AND APPROVALS 4 EDWARDS Catalog Power Supplies and Accessories LIFE SAFETY ,' INCIDENT MANAGEMENT Remote Booster Power Supplies BPS6A, R RS±ha Overview The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification/ Emergency Communication (MNEC), as well as life safety, security, and access control applications. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition lUO)OFire /iJarrn Systems UL636 (ANET UEHX7) Holdup Alarm Units and Systems UL609 (AoTx, AOD(7) Local Burglar Alarm Units and Systems UL294 (ALW, UEHX7) Access control Systems UL365 (APAW, APAW7) Police Station connected Burglar Alarm Units and Systems UL1 076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 (AMC) Central Station Alarm Unit ULc-5527 uoxxci control Units, Fire Alarm (Canada) uLc-5303 )AOD(7) Local Burglar Alarm Units and Systems (Canada) C22.2 No, 205 Signaling Equipment (Canada) 1 MEA / 476-91-E Vol 13 ' / "-. 7300-1657: 0229 Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page 1 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 Dimensions 1 0 00 Top View 1 D2-1 14 D3 0 04— D4 —*0 S Front View > ci) C/) . S • All knockouts for 3/4 in conduit (1.9 cm) Dl 101 OFIN Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. D5 06 3.375 in 12.0 in (8.6 cm) (30.4 cm) BPS NACs can be configured for a 3-3-3 temporal or continuous output. California temporal rate outputs are also available on cer- 17.0 in fain models. This makes the BPS ideal for applications requiring (43.2 cm signaling rates that are not available from the main system. D2 D3 04 3.5 in 13.0 in 6.5 in (8.9 cm) (33.0 cm) (16.5 cm) In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Power-limited wiring area Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere- hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall-not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. [2] Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. 13] Source must be power-limited. Source determines supervision, 4. when using larger batteries, make sure to position the battery terminals towards the door. DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 Route AC supply through these knockouts only (Nonpower-limited and supervised) Typical Wiring Single or cascaded booster NAC circuit > To next signaling NAG Circuit \ / device, booster, or anywhere on a notification appliance circuit V V EOL resistor Existing NAG end-of-line resistors are not required to be Fire Alarm Cl) (0 I ) NAC output #1 CD CD I I I ) NAC output #2 installed at the boosters terminals. This allows multiple Control Panel CD CD ) NAC output #3 C') I boosters to be driven from a single NAG circuit without the I - ) NAC output #4 0 0 need for special configurations. Booster Power Suoolv Configuring the Booster for AC Power Fail delay operation* TB1 Notification appliance circuit (NAC) NAC1/+ listed -UL - AUX1 EOL 15 kO - NAC2/ + AUX2 - Notification appliance circuit (NAC) NAC3/ + - AUX3 UL listed EOL 15 kO - - NAC4/ + AUX4 - 200 mAAUX Continuous lN t - Sense COM[ OUT __________ IN Eff Sense 2 COM )EOL 47 kO 109 OUT )I L Trouble C No OM CC1(S) module [1][3 I 00 Ii NC ____ -. . . Data infrom Cii previous device mo0dul[4j or Signature 4 3 2 controller Multiple CC1 (S) modules using the BPS's sense inputs B1 ° Notification appliance circuit (NAC) T NAC1/ +- jjj UL listed AUX1 Iff EOL 15 KW NAC2/ AUX2 Notification appliance circuit (NAC) UL listed AUX3 NAC3/ _ EOL 15 KW CC1(S) module 00 NAC4/ + AUX4 200 mAA1JX, - Continuous ca IN Sense 1 COM Eff I 1U OUT -EOL 47K II IN Eff U- Sense 2 COMLii JiilJ -EOL 47K OUT NOJIij -11+ F NOI - -0 Trouble COM 109 NC TB2 II CC1(S) module Data out to 00 118765 4321 next device OTIM 111VERMI L Data in from previous >J '-i--* Data out to *The Booster supports AC Power fail delay device or Signature L,. next device of three hours via its trouble contact when controller ,- dip switch SW2-6 is on. Al other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS 24V =24DC12 12V NACII/ <1,AUX1 device ____ Security EOL !d:e Ece v i device ____ AUX2 - LNAC3/ Control panel ____________ ICard reader I I Card reader controller I I controller + — Il+ - [i] Disable the BPS's ground fault jumper (JP3) [3] BPS [11 I __ er I r I t4mdevice' ______ To next _______ device or end Page 3 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 Specifications cb WARD 9 Model 65 amp Booster AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz 390 watts 580 watts LIFE SAFETY & INCIDENT MANAGEMENT Notification Appliance 3.0A max. per circuit @ 24Vdc 3.OA max. per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Contact us... Trouble Relay 2 Amps @ 30Vdc Email: edwards.fire@fs.utc.com Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary Web: Edwards-fire.com outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current 3mA @ 12Vdc, 6mA © 24Vdc EDWARDS is a UTC brand. (frornan existing NAC) 1016 Corporate Park Drive ferintein? QOmA + 35 mA for each circuit set to AUX Mebane, NC 27302 SisOdoé)t Booster Internal Alarm QtEA © 2016 United Technologies Corporation. Current All rights reserved. Signature Mounting Accomodates three two-gang modules. Space Maximum Battery Size 10 Amp Hours (2 of 12V1 OA) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing © 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model BPS*CAA provides selection for California rate, in place of temporal. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description Shipping Number Wt.,lb (kg) I BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPSGAC 6.5 Amp Booster Power Supply (ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply (220V) 13(5.9) BPS6CM 6.5 Amp Booster Power Supply with California rate 13(5.9) 10 Amp Booster Power Supply 13(5.9) BPS1 OAC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 0N230 10 Amp Booster Power Supply (220 13(5.9) BPS1 0CM 10 Amp Booster Power Supply with California rate 13(5.9) Requires installation of sepa- rate battery cabinet Related Equipment 2. BPS supports batteries greater 12V6A5 7.2 Amp Hour Battery, two required 3.4(l.6) than 24 Amp hours for access control applications only. 12V10A 10 Amp Hour Battery, two required 9.5 (4.3) For earthquake anchorage, 3-TAMP Tamper switch including detailed mounting BC-1 EQ Seismic Kit for BC-1. Order BC-1 separately. See note 3. weights and center of gravity BPSEQ Seismic kit for BPS6A or BPS1 0 Booster Power Supplies. See detail, refer to Seismic Applica- note 3 tion Guide 3101676. Approval of panel anchorage to site BC-1 Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) structure may require local BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) AHJ, structural or civil engineer 1 2Vi 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery, two required (see note 1) 20(9.07)_ 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40 (18.14) 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Page 4 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 EDWARDS Catalog Strobes, Horns, Bells, Chimes AN Rom 11. 11 (m, So CPXUnWi_tewd_Tdwc'h_nJ1-og1a LIFE SAFETY INCIDENT MANAGEMENT Field Configurable, I-ERT Ceiling Strobes Len es i se n es -- r I R E " One or more patents pending I" <E~> FCC XV. @ IVIEA C E 7125-1657: 0219 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/153/177 cd clear strobe lens models available - Switch settings ramain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind thE signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullUgi-it strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for st obes - Low current draw minimizes system overhead Approved for pulic and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - ULJULC listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Jot to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/' (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8" dia. (173 mm) (25 mm) - -- 0.60(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - 125 110 100 on no no go so an no ,n to o in 'o on an 50 en on as on Ins 110 120 90* 75\ 6 / 60* -- 15 0. Angle Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output / candela switch (see ordering information). The output I setting is changed by simply opening the I device and sliding the switch to the desired I setting. The strobe does not have to be I removed to change the output setting. The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices I not operefiewithoutelectricolpowei.Asfre fleqJenti cause power interruptions,we suggest you discuss turther safeguards with your local tire protection specialist.- To next To listed fire alarm appliance, control I end-of-line panel LJJ LCJ I or return to + + I control I equipment NEBAMEM-115i Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Light output setting, high outpufodils - "95" or "0" "115" or "C" "150" or "B" "177" or "A" RMS 1 RMS RMS RMS 330 392 502 565 432 518 643 693 Light output setting, high output models "95" or "0" "115" or "C" j "150" or "B" "177" or "A" AMS RMS 1 RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 UL Light outut iettin, stindaid moeIs "15" or "0" "30" or "C" "75" or "B" '95' or "A" Rating F RMS f RMS RMS 1 RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 Typical "45ó1 "0" 1130" or "C" "75"or "B" "95"or"A" Current RMS . RMS - RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 -24-'Vdc &P 9,00 168 194 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Housing Textured UV stabilized, color impregiated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR. GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS10A, APS6A, APS1OA, 064, 0500, Fireshield Plus 3, 5 and 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. Page 3of4 DATA SHEET E850010557 Not to be used for installation purposes. Issue 1 Ordering Information EDV1A.RDS Light output switch settings for UL 1971 listed models are selectable by numeric . - candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. LIFE SAFETY & INCIDENT MANAGEMENT Model Housing j Marking j Lens Strobe Life safety Appliances (0/w running man icon screen printed on housing) GC-VM White None Clear Selectable 15, 30, 75, 0r95cd 1.81b. (0.82 kg.) White FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95, 115, 150, 0r177cd GCF-VMH White "FIRE" ECS/MNS Appliances (no running man icon on housing) GCWA-VMA White "Alert" Amber Selectable A, B, C, 0 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output A, B, C or 0 Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. ERT -- ) -. Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 A un, 71251657: 0284 S218, C S5389, C E MEA EDWARDS Catalog h Strobes, Horns, Bells, Chimes WT.0.61M.11.6 LIFE SAFETY , INCIDENT MANAGEMENT Field Configurable Horns and Strobes Gem- s- is-=S ECS/MNS appliances available with clear or amber lenses. L Ai ' A LI L = E ALERr Overview The Genesis line of fire alarm and mass notification/emergency communications (ECS/MNS) signals are among the smallest, most compact audible-visible life safety signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular re- flectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the UL-1971 and ULC-5526 light distribution requirements. Genesis strobes and horn-strobes offer selectable candela output by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 od output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between fire alarm and mass notification alerts. Standard Features Unique low-profile design - The most compact UL-1971/ULC-5526 listed strobe available - Ultra-slim - protrudes less than one inch - Attractive appearance - No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 Cd model available ECS/MNS models available Easy to install - Fits standard 1 -gang electrical boces - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribuion - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improves soundpenetration - Field-programmable temporal strobe output option Page lof6 DATA SHEET E850010573 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as wall-mount- ed public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions further safeguards such as backup power supplies may be required Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Horn-only models may be ceiling-mounted or wall-mounted. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications. Available with amber lenses and optional ALERT housing labels, they are ideal for applications that require differentiation between fire alarm and mass notification alerts. nstallation Genesis horns and strobes mount to any standard one-gang sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. - - All Genesis signals come pre-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting :. hardware. The shallow depth of Genesis ' devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. 1 Field Configuration Genesis Horn/Strobe Temporal horn and horn-strobe models with optional trim plate are factory set to sound in a three-pulse temporal pattern. Units may be con- figured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required when horn- strobe models are configured for coded systems. Non-temporal, horn-only models sound a steady tone. Genesis clear strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis clear strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cuffing a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. G Polarity shown in alarm condition To next appliance, end-of-line or return to control equipment Note: Strobes must have continuous voltage. Page 2 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1 Horns Wall or Ceiling Mounted Temporal Horns (G1-HD UL iiHiah dRTiow 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16Vfwr 51 37 24 Vfwr 69 52 33Vfwr 76 70 Typical: .High dB Low dB Current RMS RMS 16 Vdc 22 17 20 Vdc 24 19 24 Vdc 27 22 33 Vdc 32 26 16Vfwr 34 30 20Vfwr 40 34 24 Vfwr 45 38 33Vfwr 52 47 Wall or Ceilina Mounted Horns 1G1-PI - Max. Current, UL Designation Voltage Range RMS Regulated 24 16-33 Vdc 13 mA Vdc 24fwr 16-33Vfwr ii mA Typical Current - RMS 24 Vdc 10 24 Vdc 11 31 Vdc 12 20Vfwr 9 24Vfwr 10 Current values are shown in mA. Current Draw Strobes, Horn-Strobes UL 15 cd* 30, cd* 15/75 cd** 75àd* 1 - 110 cd* Rating RMS RMS RMS RMS RMS 16 Vdc 103 141 152 255 311 16Vfwr 125 179 224 346 392 Gi-VM multi-cd; "(51 --Vi 575 fixed 15/15 cd Typical cd 30 cd 15/75 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 85 127 150 245 285 20 Vdc 71 98 123 188 240 24Vdc 82 104 1L52 191 33 Vdc 46 64 84 112 137 16Vfwr 119 169 223 332 376 20Vfwr 103 143 189 253 331 24Vfwr 94 129 169 218 262 33Vfwr 87 112 148 179 205 Rating RMS RMS RMS RMS RMS 16 Vdc 129 167 172 281 337 16Vfwr 176 230 269 397 443 Typical t5cP — jçd- 15/75 — 75 cd 1l0td Current RMS RMS RMS RMS RMS 16 Vdc 102 135 160 246 309 20 Vdc 88 109 137 193 248 24 Vdc 122 161 33 Vdc 74 72 106 124 154 16Vfwr 144 182 247 352 393 20Vfwr 141 162 220 274 362 24Vfwr 136 152 203 235 282 33Vfwr 125 144 196 201 232 Wall Temporal Horn-strobes - Low dB Setting Wff.!TeL M multi-cd J V1 575 fixed 15/75 cd - 15 30 15/75 75 110 *GiHD UL cd* cd* .cd** cd cd* **G1 F-HE UL - Rating 15 cd* 30 cd* 15/75 75 cd cd* 110 cd* RMS AMS R RS RMS RIVISi 16 Vdc 122 160 146 1 274 336-- 16 Vfvvr 162 216 231 1 383 429 *G1 -HDVM multi-cd **G1 F-H OV1 575 fixed 15/75 cd 1Typical 15 cd 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 16Vfwr 128 180 241 344 389 20Vfwr 118 157 213 266 343 24Vfwr 113 144 195 230 279 33Vfwr 112 137 182 197 226 Page 3 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1 dBA output Temporal Horns, Horn-strobes (G1-HD, G1-HDVM series) High - 4 _J Average f Peak dB Setting Temporal Steady Temporal/,,.Temporal/ Steady Steady 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 96.9 99.5 LowdB UL464 Average Peak Setting Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc t76.0 80.1 863 - 892 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Steady Tone Horns (G1-P series) UL464 Average Peak 16 Vdc (7 dBA, min 85 dBA 91 dBA 16 Vfwr 77 dBA, min 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet (3.01m). UL464 values measured in reverberant room. Average and Peak values are measured in anechoic chamber. Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at lOft) -75 -60 60 15 Light output - (effective cd) Percent of UL rating versus angle 1. 10 = 00 00 70 00 0000 110 .75 // 30. 0. Specifications Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Strobes and horn-strobes are for wall-mount installation only. Horn-only models may be ceiling- or wall-mounted. Mounting Flush mount: 21/2 inch (64 mm) deep one-gang box (indoor only) Surface mount: Model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor only: 32-120°F (0-495C) ambient temperature. 93% relative humidity Agency listings/approvals UL 1971 (S218), UL 1638 (S218), UL 464 (S218), ULC S525, ULC S526, CSFM, CE, FCC, MEA. (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2" x 2-3/4" x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5,, (127 mm); Height- 5-7!8 (149 mm); Depth - ½ (13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc F\NR (or coded (audible NAC only) when used with optional Gi M Genesis Signal Master) GI -VM series strobes: non-coded, filtered 16 - 33 Vdc or unfiltered 16-33 Vdc F\NR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe output rating UL 1971: 15 cd (fixed 15/75 cd models) UL 1638, ULCS526: 75 cd (fixed 15/75 cd models) G1-VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Strobe flash rate Gi M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of horns on same circuit S1GA-CC1S, SIGA-MCC1S, SIGA-CC2A, SlGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1OA, APS6A, APS10A, i064, i0500, Fireshield Plus 3, Sand 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. Horn pulse rate Gi -HD temporal-tone horns and G1 -HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely within 10 milliseconds. G1-P steady-tone horns: continuous, steady tone only Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle Page 4 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1 Candela Output Lens Switch Switch Switch Switch Color Rating Position A Position Position Position B C D Amber UL 1638 110 cd 75 cd 30 cd 15 cd Amber UL 1971 88 cd 60 cd 24 cd 12 cd Clear i 1971 L 1Ocd rl 7Sc fl rt r.rl 15 cd Fire appliances available with white or red housings. flVT\ , tj FIRE i t c - - - - - . . ECS/MNS appliances available with clear or amber lenses. * Equivalent Rating E El /LET{ ALE Ordering Information Model j Housing Marking ieJ_'o' IHorn ' ShiWt.lbs(kg) Fire Alarm Aooliances (ciw rutlnina man icon screen orinted on housina G1-VM White None Clear Selectable 15,30,75,or110cd Strobe only 0.25 (0.11 Gi F-HD White FIRE Clear Horn only Selectable high/low dB 0.25 (0.11)- G1F-H0V1575 White FIRE Clear 15/75 Cd1 Temporal hub dB-24V 0.25 (0.11)- ElDVM White FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11 Gi F-P White FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) Gi F-V1575 White FIRE Clear 15/75 cd' Strobe only 0.25 (0.11) iFVM White FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1-HD White None Clear Horn only Selectable high/low dB 0.25 (0.11) G1-HDVM White None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1-P White None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) GIRF-HD Red FIRE Clear Horn only Selectable higwlowdB 0.25 (0.11) G1RF-H0V1575 Red FIRE Clear 15/75 cd' Temporal hi/lo dB-24V 0.25 (0.11) G1RF-HDVM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1 RF-P Red FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1RF-V1575 Red FIRE Clear 15/75 cd' Strobe only 0.25 (0.11) Gi RF-VM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) G1R-HD , Red None Clear Horn only Selectable high/low dB 0.25 (0.11) Gi R-HDVM Red None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) G1 R-P Red None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) G1R-VM Red None Clear Selectable 15,30,75,or110cd fStrobeonly 0.25 (0.11) ECS/MNS Appliances (no running man icon on housing) G1WA-VMA White ALERT Amber Selectable A,B,CorD Strobeonly 0.25(0.11) G1WA-VMC White ALERT Clear Selectable15,30,75,or110cd Strobeonly 0.25(0.11) G1WN-VMA White None Amber Selectable A,B,CorD Strobeonly 0.25(0.11) Gi WN-VMC White None Clear Selectable15,30,75,or110cd Strobeonly 0.25(0.11) Trim Plates G1T White None GenesisTrimPlate(for two-gang or 4" square boxes) 0.15(0.7) G1 FIT Red None GenesisTrimPlate(for two-gang or 4" square boxes) 0.15(0.7) G1T-FIRE White FIRE Genesis TrimPlate(for two-gang cr4" square boxes) 0.15(0.7) GiRT-FIRE Red FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15(0.7) G1WL-ALERT White ALERT Genesis TrimPlate(for two-gang or 4"squareboxes) 0.15(0.7) Surface Boxes 27193-16 White N/A One-gang surface mount box 1(0.4) 27193-11 Red N/A One-gang surface mount box 1(0.4) I These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd output component complies with 1-11-1 971, while the 75 cd output component complies with UL 1638. Page 5of6 DATA SHEET E850010573 Not to be used for installation purposes, Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 6 of 6 DATA SHEET E85001-0573 Not to be used for installation purposes. Issue 1 Lim ted es LIFE SAFETY ' INCIDENT MANAGEMENT Field Configurable Ceiling Horn -Strobes EDWARDS Catalog Strobes, Horns, Bells, Chimes One or rnre patents pending. FCC - .. MEA ( E 7300-1657: 0202 S218 Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150,1177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 of 4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid, epileptic sensitivity. NOTE The flash intensity of some visible signals my not be adequate to alert or waken occupants in the protected area Research indicates that the intensity of strobe needed to awaken 90 of sleeping persons is approximately1 100 Cd EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd WARNING: These devices will not operate without electrical power. As tires trequentl cause power interruptions further safeguards such as backup power supplies may be required Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level hang a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions 6.5" dia. (173 mm) - /7 I 10" 25mm) 060(15!) Page 2 of 4 Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Polarity alarm c next Dliance, I-of-line etum to ontrol ipment Note: Strobes must have continuous voltage. DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting 1 UL Rating 15 c RMS 30 c RMS 75 c RMS 95cd RMS 16 Vdc 147 190 316 372 16Vfwr 189 253 417 451 9ypica1 - I dij. ?Ocd - c_75-6d—z--5cd Current RMS Mean.— RMS Mãtt RMS Wan- RMS _an 16 Vdc 111 95 152 143 281 276 333 328 20 Vdc 91 80 124 117 219 214 257 251 ?4'dc 80 ifl 108 185 18212 33 Vdc 69 62 89 84 144 140 160 156 16Vfwr 153 81 218 123 388 240 420 268 20Vfwr 141 70 190 100 325 188 378 219 24Vfwr 135 64 176 90 280 154 310 180 33Vfwr 139 61 167 80 241 122 254 133 GC-HDVM Temporal Horn-strobe: Low dB Setting ,t Typical l5cd - 30cd 75 c 95d Current RMS Mean RMS Mean RMS Mean .RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 18- 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting 95cd 115&1 150&1 177 Cd RMS -RMS RMS RMS. 341 399 506 570 487 578 670 711 GC-HDVMH High Cd Temporal Horn-strobe: High dB Setting - 95d - 115cd 150cd 177cd RMS Mean RMS Mean RMS Mean RMS Mean 324 322 377 374 477 474 554 551 258 256 299 296 369 366 417 414 220 217 252 249 304 301 341 338 172 169 188 185 223 220 244 241 463 265 535 312 665 400 718 442 392 211 439 240 517 287 587 334 346 179 382 212 458 246 498 271 296 142 323 152 358 178 387 194 GC-HDVMH High Cd Temporal Horn-strobe: Low dB Setting rgsd 115 cd 150 cd 177Td RMS Mean RMS Mean RMS Mean RMS Mean 1 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 432 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA_output Light output - (effective cd) Percent of UL rating versus angle High dB UL464 Average Peak (Setting Temporal -, Steady Temporal! Temporal/ Steady Steady 16 Vdc 798 832 90.6 T 93.6 4 93.6 96.6 24 Vdc 851 33 Vdc 85 87.8 95.7 j 98.7 Low dB 1 UL464 Average Peak Setting Temporal Steady Temporal! Temporal! 1 Steady Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 80.9 85.9 1 91.8 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. 60* -36 15 Page 3of4 DATA SHEET E85001.0559 Not to be used for installation purposes. Issue 1 Specifications 1(t3JtIJ}R D S Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- IWO- (5!,..wl 0 ULtiammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) LIFE SAFETY & INCIDENT MANAGEMENT Mounting North-American 4" square box, 21/8" (54 mm) deep (indoor wall or ceiling applications only). Contact us... Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 Email: edwards.fire@fs.utc.com AWG (0.75 mm2 to 2.5 mm2) wire size Web: Edwards-fire.com Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-5526, year 2004 UL EDWARDS is a UTC brand. Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies 1016 Corporate Park Drive with UL1 480. All horn-strobes comply with ADA Code of Federal Mebane, NC 27302 Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered © 2016 United Technologies Corporation. Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) All rights reserved, when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS1OA GC-H DVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, 1/2 sec ON, 11/2 sec OFF, then repeat cycle Ordering Information Catalog Housing Marking Description Number Color - - - - Ship Wt. lbs GC-HDVM White None White "FIRE" Genesis Ceiling/Wall Horn-Strobe GCFR-HDVM Red "FIRE" with selectable 15, 30, 75, or 95 cd output GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories Gi M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (023) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. Page 4 of 4 DATA SHEET E85001-0559 Not to be used foi- installation purposes. Issue 1 0.82 (1.8) STATE FIRE MARSHAL LISTING SHEETS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. t6TT5i:0t35 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XRI50, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers cit?714, 714-8, 714-16, 715, 715-8, 715-16: Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 2631-1: Cellular Communicator *(May be used as the standalone primary communicator) *263LTE: Cellular Communicator (NOT for use with XR350) *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter *Rev 03-07-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Burglary and other non-fire functions were not examined. *Rev 03-07-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 057R02 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models BPS6A, BPI, PS6A/230, BPS10A/230, BPS6CAA, and BPSIOCAA remote booster power supplies. *Models APS6A, APS6A/230, APS6CAA, APS10A, and APS10Af230 Auxiliary Power Supply. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:229 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7l 1I Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM, GcEVMGCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G1M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SlGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, 0r95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7*2a;_~51:657 02183= Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models G1-VM, G1R-VM, iEVM, G1RF-VM, GI41575, G1R-V1575, GIF-V1575, G1RF-V1575, G1WA-VMC and G1WN-VMC synchronizable type strobe lights. The suffix R refers to red and W refers to white color enclosure; the suffix F refers to the word 'FIRE" refers to a silk-screened word "FIRE" on the strobe housing; the A in the model number indicates (Alert) marking; N in the model indicates no marking. Intended for indoor and mounted on a wall only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33VdcNFWR Candela G1-VM and G1W-VMC series 15cd, 30cd, 60cd, 75cd, 1 10c Selectable G1-V1575 series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Units are synchronizable when used with Models Gi M or GI M-RM sync module (CSFM Listing No. 7300-1657:201) which may employ Models SIGA-CC1S or SIGA-MCC1S Auto-Sync output modules as an accessory (CSFM Listing No. 7300-1657:121). For indoor use and wall mount only. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:218 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 00 ~11 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1O262i Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST' G1-HV15, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -HOV75, -HOV1I0, GlF-HOVI5, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, 1:FHDV.M, G1RF-HDVM, GC-HDVM, GC-HDVMH, ®CFRVft/, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1R-HDV1575, Gi F-HDV1575, and Gi RF-HDV1 575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33VdcIVfwr - Models Gi-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, Gi F-HDV1575, Gi RF-HDV1 575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVM H, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, Gi F-H Dvi 575, 31 RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC.HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division