Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2020-0159; Permitty PERMIT REPORT Cdisbad cci of Print Date: 10/17/2024 Permit No: FPC2020-0159 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 2121304400 Track U: Applied: 09/17/2020 Valuation: $0.00 Lot U: Issued: 10/15/2020 Occupancy Group: Project #: - Finaled Close Out: 10/11/2024 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Salcedo, Felix Plan Check U: Project Title: Description: THERMO FISHER -SPRINKLERS FOR NEW MEZZANINE (66 HEADS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC LORRIE DIERDORFF 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (619) 954-8613 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov No. 226 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Thermo Fisher (All areas Nos. 2 -7) SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 5781 Van Allen Way CITY: Carlsbad PHONE: (858) 513-4949 x1310 (Western Fire Protection) FAX NUMBER: Largest Building (ft.2) Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Van Allen Way west of College Blvd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 131 PSI Hydrant Number (if applicable):H61391 & H61385 Elevation of test: 248 Feet Main Size: 8 INCH Pressure Zone: 550 Feet bate/Time of Test: Pitot Tube Reading: Psi, Corresponding Flow: GP Total Flow: 2,700 GPM Residual Pressure 108 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the City's maximum velocity criteria. The fire flow that meets both velocity and pressure criteria is 2,700 gpm. Flow was split evenly between the two hydrants shown. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer _R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: Title/Org: P_ie_Mana er Date: 05/07/2020 • SECTION DESCRIPTION CONTENTS 1. SPRINKLERS A. GLOBE GL8118 QRUPRTGHT 8K 2. PIPE & FITTINGS BULLMOOSE SCH 10 & SCH 40 BLACK STEEL PIPE WHEATLAND SCH 10 & SCH 40 BLACK STEEL PIPE TEX-TUBE SCH 10 & SCH 40 BLCK STEEL PIPE VICTAULIC FIRELOCK FITTINGS VICTAULIC FIRELOCK RIGID COUPLING #009N VICTAULIC FIRELOCK RIGID COUPLING #005H VICTAULIC FIRELOCK FLEXIBLE COUPLING #75 VICTAULIC No. 50 CONCENTRIC GROOVED REDUCER VICTAULIC STYLE 750 REDUCING COUPLING VICTAULIC STYLE 920 MECHANICAL-T BOLTED BRANCH OUTLET VICTAULIC STYLE 922 MECHANICAL-T BOLTED BRANCH OUTLET MERIT WELDED OUTLET FITTINGS SMITH COOPER DUCTILE IRON THREADED FITTINGS 3. VALVES A. WATTS MODEL 709 DOUBLE DETECTOR CHECK BACKFLOW 4. HANGERS & EQB TOLCO FIG 200 ADJUSTABLE BAND HANGER TOLCO FIG 25 SURGE RESTRAINER TOLCO FIG 100 ALL THREAD ROD TOLCO FIG 58 THREADED SIDE BEAM BRACKET F. POWERS DeWALT HANGERMATE+ SUSPENDER FOR STEEL TOLCO FIG 980 SWIVEL SWAY BRACE ATTACHMENT TOLCO FIG 4L & 4LA IN-LINE SWAY BRACE ATTACHMENT TOLCO FIG 1000 & 100 1 SWAY BRACE ATTACHMENT ERICO CADDY BRANCH LINE RESTRAINT 5. MISCELLANEOUS ARGCO FIRE SPRINKLER SPARE HEADBOX ARGCO FIRE SPRINKLER IDENTIFICATION SIGNS MATERIALS MAY BE SUBSTITUTED WITH LISTED EQUAL DUE TO PRODUCT AVAILABILITY* 4077 -GL&)BE SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 GENERAL DESCRIPTION Globe Series GL-QR sprinklers are Listed Quick Response sprinklers which utilize a 3mm frangible glass bulb as the thermosensitive operating element. These sprinklers are available in upright, pendent, and recessed pendent orien- tations. They are Listed and Approved as Standard Cover- age sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13; FM 2-0). These sprin- klers are available in various K-factors, temperatures and finishes as shown. Recessed escutcheons with either 1/2' or %" vertical adjustment are available (See Approvals Ta- bles for appropriate sprinkler/escutcheon combinations and Listings). Some pendent models are additionally available with a special "Seismic" escutcheon to meet the IBC-ASCE/ SEI 7 requirements for use in seismic design categories C, D & E. OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. TECHNICAL DATA SIN Upright: GL2815, GL4215, GL5615, GL8115, GL8118 Pendent, Recessed Pendent: GL2801, GL4201, GL5601, GL8101, GL8106 Approvals cULus" FM • LPCB • CE See Approval Tables Maximum Working Pressure 175 psi (l2bar) Factory tested to 500 psi (34 bar) Minimum Operating Pressure 7 psi (48 kPa) Temperature Rating See Approval Tables Materials of Construction Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy. Seal - teflon Bulb - glass with alcohol based solution, 3mm Escutcheon Assembly - carbon steel SEP 2019 RECESSED PENDENT UPRIGHT PENDENT L RECESSED PENDENT SEISMIC IBCIASCEiSEI CODES FINISHES AND ACCESSORIES Finishes Factory Bronze • Chrome • White Polyester Black Polyester - special order Escutcheons Brass • Chrome • White Polyester• Black Polyester Wrenches Standard • Recess • 1/2" NPT • 3/4" NPT NOTE: Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be expected when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmo- spheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, humidity, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTE: Users should refer to Globe's web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. PAGE 1 OF 6 GFS-1 00 INSTALLATION NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak- age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads; 20 ft. -lb. (26.8 Nm) to 3/4 inch NPT threads. Stepi. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. FIGURE 1: STANDARD SPRINKLER WRENCH ½" NPT PIN 325390 NPT P/N 312366 44 L4-~~7 Mql FIGURE 2: RECESSED SPRINKLER WRENCH V NPT PIN 325391 3/4" NPT P/N 325401 CARE AND MAINTENANCE Prior to installation, it is important to read and follow the "Sprinkler Caution" sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe's web site (www.globesprinkler.com). Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- suiting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler's coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner's responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). SEP 2019 GFS-100 PAGE 2 OF 6 TABLE A: UPRIGHT SPRINKLER APPROVALS SIN GL2815 GL4215 1 GL5615 1I GL8115* GL8118(1) ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR 2.8 (40 metric) 4.2(60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2' (15mm) 1/2" (15mm) 1/2" (15mm) 1/2° (15mm) 3/4" (20mm) HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C)°° 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c/05 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. DEFLECTOR FRAME COMPRESSION SCREW BULB 2-1/4° ( BULB SEAT 57.1 mm) H FLAT IG OBE WRENC H NPT 1/2" 7/16° (11.1 mm) NOMINAL MAKE-IN FIGURE 3: SERIES GL-QR UPRIGHT SPRINKLERS GL2815, GL4215, GL5615, GL8115 COMPRESSION BULB BULB SEAT— WRENCH 2-7/16° (62 mm) 314° NPT SEP 2019 1/2° (12.7 mm) NOMINAL MAKE-IN FIGURE 4: SERIES GL-QR UPRIGHT SPRINKLERS GL8118 GFS-1 00 PAGE 3 OF 6 TABLE B: PENDENT SPRINKLER APPROVALS SIN GL2801 GL4201 (1) GL5601 (1) GL8I0I * GL8106 (1) ORIENTATION PENDENT PENDENT PENDENT PENDENT PENDENT K-FACTOR 2.8 (40 metric) 4.26O metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2" (15mm) 1/2" (15mm) 1/2(15mm) 1/2" (15mm) 3/4" (20mm) HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) FM Approved NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c/05 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) CE NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. SEP 2019 7/16° (11.1 mm) NOMINAL MAKE-IN 1/2° NPT WRENCH FLAT BULB S 8O1OI $ BULB COMPRESSION SCREW FRAME DEFLECTOR FIGURE 5: SERIES GL-QR PENDENT SPRINKLERS GL2801, GL4201, GL5601, GL8I0I 1/2° (12.7 mm) NOMINAL MAKE-IN 3/4" NPT WRENCH FLAT BULB SEAT 2-7/16' BULB COMPRESSION SCREW FRAME DEFLECTOR FIGURE 6: SERIES GL-QR PENDENT SPRINKLERS GL8106 GFS-1 00 PAGE 4 OF 6 TABLE C: RECESSED PENDENT SPRINKLER APPROVALS SIN GL2801 (2) GL4201 ((2) GL5601 (11(2) GLBIOI * (1)(2) GL8106 (1)(2)(3) ORIENTATION RECESSED FEND. RECESSED PEND. RECESSED FEND. RECESSED PEND. RECESSED FEND. K-FACTOR 2.8 (40 metric) 4.2 (60 metric) 5.6 (80 metric) 8.0 (115 metric) 8.0 (115 metric) NPT 1/2' 1/2' 1/2" 1/2" 3/4" HAZARD L.H. L.H L.H./O.H. L.H./O.H. L.H./O.H. 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) cULus Listed 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) 286°F (141°C) FM Approved 135°F (57°C) 135°F (57°C) 1 Note: /2 Adjustable Recessed NA NA 155°F (68°C) NA 155°F (68°C) 175°F (79°C) 175°F (79°C) Escutcheon only 200°F (93°C) 200°F (93°C) 135°F (57°C) 135°F (57°C) LPCB 155°F (68°C) 155°F (68°C) Ref. No. 147c/05 NA NA 175°F (79°C) NA 175°F (79°C) 200°F (93°C) 200°F (93°C) 286°F (141°C) 286°F (141°C) 135°F (57°C) 135°F (57°C) '.'E NA NA 155°F (68°C) NA 155°F (68°C) 175°F (79°C) 175°F (79°C) 200°F (93°C) 200°F (93°C) * FOR RETROFIT USE ONLY cULus LISTED CORROSION RESISTANT SPRINKLER WITH POLYESTER COATING cULus I LPCB ICE APPROVED WITH 1/2" ADJUSTABLE AND 3/4" ADJUSTABLE RECESSED ESCUTCHEON FM APPROVED FOR BRASS FINISH ONLY -2 15/16" DIA, 2 DIA. MIN. HOLE IN CEIUI -1 29/32" DIA. REDUCER 1/8" MIN. MAX. - 1/2° AD). MAX. -3/4" AD). 1/8° (3mm) MIN. 1/8° (16mm) MAX. - 1/2" (12mm) AD). 7/8" (22mm) MAX.3/4" (1.) AD). DIA. REDUCER CEIUNG 1" MIN. 13/4- MAX. —L 1 (25mm) MIN. 11/2" (38mm) MAX. - 1/2 AD). 1314" (44mm) MAX. - 3/4 AD). FIGURE 7: RECESSED ESCUTCHEON TABLED: STANDARD ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2° NPT 3/4" NPT Chrome 325422 325423 Brass 325424 325420 White Polyester 325426-W 325427-W Black Polyester 325426-B 325427-B Stainless Steel 326140 NA 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2" NPT 3/4" NDT Chrome 332071 326040 Brass 332072 326041 White Polyester 332073-W 326042-W Black Polyester 332073-B 326042-B FIGURE 8: SEISMIC RECESSED ESCUTCHEON Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E. TABLE E: SEISMIC ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326170 326177 White 326172-W 326178-W 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2" NPT 3/4" NPT Chrome 326201 326208 White 326203-W 326210-W SEP2019 GFS-100 PAGE 50F6 TABLE F. PART NUMBER SELECTION PART NUMBER SIN + TEMPERATURE + FINISH xxxx xxx xx T -L F SIN I II TEMPERATURE 0L2815 2815 GL4215 4215 GL5615 5615 GL8115 8115 GL8118 8118 GL2801 2801 GL4201 4201 GL5601 5601 GL8101 8101 GL8106 8106 135 135°F (57°C) 155 155°F(68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F(141°C) FINISH LIi BRONZE 02 CHROME LiI WHITE POLYESTER 04 1 BLACK POLYESTER Note: All combinations may not be available. Refer to Listing/Approval Tables for available listed combinations. ORDERING INFORMATION SPECIFY: SPRINKLER Quantity• SIN • Orientation• Orifice• NPT• Temperature Rating Finish • Part Number (See TABLE F) ESCUTCHEON Quantity. Finish• Part Number (See TABLE D & TABLE E) WRENCH Quantity. Part Number 1/2" NPT Standard ....................325390 3/4" NPT Standard ....................312366 1/2" NPT Recess . . . . . . . . . . . . . . . . . . . . . 325391 3/4" NPT Recess . . . . . . . . . . . . . . . . . . . . . 325401 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 989-846-4583 . www.globesprinkler.com Technical Support. 989-414-2600. techservicegIobesprinkler.com 6) SEP 2019 GFS-100 PAGE 6 OF 6 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. 1.315 _ . 1.097 . 1.41 Ibs/ft 91 1 1/4 ,166O I1442. 1.81 lbs/ft 61 1 1/2 1 1.900 1.682 - 2.09 lbs/ft i 61 2.375 L12 2.157 2.64 lbs/ 37 ...... /2 - 2.875 11 2635 35 lbs/ft i 30 13... 4 3.500 L4.500 II 3.260 Ibs/ft 19 _____Jbs//ft 1.9 Schedule 40 Pipe 1/4 1.315 1.660 1.049 1.380 1.68 lbs/ft 2.27lbs/ft 70 51 1 _ 2 2.375 1L.._.06? 121/2 2.875 2.468 0 lbs/ft 1L35o0 HL_4.50 ____ 3.068 ~8 lbs/ft 19 1 4 4.P26IL_10.8Ojbs/ft __19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, U Chesterfield, MO 63017 contact your salesperson c us (800) 325-4467 todayat (800) 325-4467 or USTED BUI..L. MCOSE TLE øfPANV FAX: (636) 537-2645 (636) 537-2600 in the USA, ______ www.bullmoosetube.com or from Canada FM ACf1FRRcompany e-mail: saIes(äbu11moosetube.com call (800) 882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed, Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES mm j[] 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1~i 1.9001{ 48.3 1.682 42.7 1092] 2.09 II 3.11 J[ 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2' 2.B75j[_7j 2.635 Jf 66.9 .127 3.05 3.53 II 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4.500 114.3 4.260 108.2 IL.120 5.62 II II_1.6 19 5 5.363 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 '1 r L 6.625 168.3 6.357 161.5 L.13 _jE 9.30 l 13.85 1 1.0 If 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES Iii.i_mmjJt mm [In.iT]['J1 k9/Jt CRR jNftj 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 . 1c- ________ 1% 1.660 Il 42.2 1.380 35.1 j .140 3.56 2,27 3.39 H 1.00 51 it 1% 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 '2 375][ 2067[ 154391 366 545 100 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). C @ APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: fl BLACK LI HOT-DIP GALVANIZED P800.2578182 Wheatland Tube 700 South Dock Street Sharon, PA 16146 I F 724.346.7260 I infowheatland.com wheatland.com M)ol Chi is — manufacturer secifi Schedule 10pie Specificé tion: 9 , \ \• \\ 1 SCHEDULE 10. High Strength Steel FirSprinkler'Pipe Me 10 steel sprinkler pipe is available in the listed nominal diameters for wet, dry, In and deluge type sprinkler systems with unthreaded ends intended to be joined by or by Listed rubber gasketed fittings as indicated in Underwriters Laboratories Listings ory for Fittings, Rubber Gasketed (VIZM), when installed in accordance with the fitting y Mutual approved for roll-grooved, plainéd and welded lengths for wet systems. H F 1 11 products are coated with a durable, paintable, environmentally approved acrylic or water-based coating. 11 111 11 11 11 ATM A995, Grade A, Typé"E 1 E: 1 I NPS NOMINAL WALL WEIGHT WEIGHT NUMBER LENGTH' RATED CORROSION (inches) ID .-(znchesj THICKNESS; inche') lb/fO -FILLED LENGTHS PER H 2O (fi) PRESSURE (psi)RATIO RESISTANCE (CRR) (lb/fl) BUNDLE UL FM SCHH, 10 1 ScH. 40 3 3.260 .120 4.33 7.95 24 - 21 300 300 3.00 1.0 4 .- 561— 1179 19 - - 21 300 300 190 10 6 6.357 134 929 2304 10 21 300 300 121 10 J 8 8.249 188 16.94 40.10 7 21 300 300 1.81 1.0 Notes: J. - Other iéngthsareava1lblupon request. SCI-iEDULE40 High.Strength Steel Fire Sprinkler Pipe I / Schedule 40 steel sprinkler pipe is available in the listed nominal diameters for wet, dry, preaction and deluge type sprinkler systems with unthreaded ends intended to be joined by welding or by Listed rubber gasketed fittings as indicated in Underwriters Laboratories Listings under the category for Fittings, Rubber Gasketed (VlZM), when installed in accordance with the fitting manufacturers specifications. It is Factory Mutual approved for roll-grooved, plain-ended and welded lengths for wet systems. Schedule 40 pipe products are coated with a durable, paintable, environmentally approved acrylic or water-based coating. Specification: ASTM A795, Grade A, Type E NPS NOMINAL WALL WEIGHT WEIGHT NUMBER LENGTH' RATED CORROSION (inches) ID THICKNESS (lb/fl) H2O LENGTHS (f1) PRESSURE RESISTANCE (inches) (inches) FILLED PER (psi) RATIO (CRR) (lb/fl) BUNDLE L_ 6 82 1 4.026 6.065 7.981 3.068 21__. .237 . .280 .322 7.58 -. 10.79 18.97 10.78 24 19 10 7 21 21 21 21 16.31 31.50 28.55 50.24 Notes: - Other lengths are available upon request. - 8 inch SCH 30 (.277 inches) pipe can be supplied from 8" Sch 40. C(U)USLISTEOTEX-TUBE FIRE -PROTECTION PIPE ___ APPPflUFfl,i - UL FM Refrrence Value 1.0 - 300 300 300 300 1.0 300 300 - 1.0 300 - 300 '\ 1.0 ' Victaulic® FireLockTM Fittings A—Cta-ulicr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes 1 ¼ - 8'/DN32 - DN200 Maximum Working Pressure Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials Carbon steel 2.0 CERTIFICATION/LISTINGS C@.zeusm Ral EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: o Orange enamel. O Red enamel in Europe, Middle East, Africa, and India. 0 Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic company. All rights reserved. 1 ictaulic victaulic.com 4.0 DIMENSIONS k-CtoE.1 °toE°l Cto" 0 0 C to No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap Approximate Approximate Approximate Approximate Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 1 ¼ 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 1 ½ 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 0N65 76.1 76 1.5 57 1.1 76 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 - 124 6.9 - - 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. viCtauliC.Com \,Ltaulic victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No. 001 No. 003 Nominal Outside Size Diameter 900 Elbow 450 Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1'/4 I1.660 - - - - DN32 42.4 1½ 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DNSO 160.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 - DN65 I76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 - 1.5 6.4 3.2 15.3 6A 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 -- 5.563 - 8.5 4.2 -_- 21 8.5 141.3 - 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 --- 50 - 9 -----. 4.9 .o -- 9.6 -- _ 58.8 2.9 1.5 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 16.500 9.8 4.9 245 9.8 65 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1 1.5 . 10.1 4.0 8515 13.0 - 33.0 13.0 ¶2163 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 0912017 © 2017 Victaulic Company. All rights reserved. victaulic.com '\j1taUIiC victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic® FireLock TM Rigid Coupling Style 009N 10.02: Victaulic® FireLock T" Rigid Coupling Style 005H with Vic-Plus°" Gasket System 29.01: Victaulic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual properly right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com '/ctauIic Victaulic® FireLockTM Installation-Ready1M Rigid Couplings JtauIicr Style 009N and Style 109 10.64 1.0 PRODUCT DESCRIPTION Available Sizes Style 009N: 11/4 - 12/DN32 - DN300 Style 109: 11/4 —2 ½/DN32 - 73.0 mm Pipe Material Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic. Maximum Working Pressure Up to 365 psi/2517 kPa. Function Joins carbon steel pipe with grooved ends conforming to publication 25.01. Provides a rigid pipe joint designed to restrict axial or angular movement. 2.0 CERTIFICATION/LISTINGS LPCB CE USM C104-1a/36 EN 10311 Regulation (EU) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date virfuiIir rnm 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. 1 JtauIicr 2 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic company. All rights reserved. victaulic.com J C_ t _Su Iicr victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Orange enamel (North America, Asia Pacific) Red enamel (Europe) El Optional for Style 009N: Hot dipped galvanized Gasket: (specify choice) Grade "E" EPDM (Type A) Vic-PIusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-400C and above. Not compatible for use with hot water services or steam services. NOTES Reference should always be made to publication 1-100, Victaulic Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). El Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' I Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish. victaulic.com 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling A. RIVER -. Size Maximum Maximum Allow. - Bolt/Nut Dimensions Weight Actual Outside Working End Pipe End Pre-assembled Joint Assembled Approx. X Y X V Nominal Diameter Pressure2 Load2 Separation3 Qty. Size Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DN mm kPa N mm - mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 , 3/8 X2 3.13 5.00 2.75 5.00 2.00 1.4 0N32 42.4 2517 3514 2.54 M10x51 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.10 1 3/8 8 x 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 M10x51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 2 3/8X21/2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7193 3.05 M10x63_- 102_143 89 143 51 0.9 21/2 2.875 365 2370 0.12 2 3/8 X2½ 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 - M10x63 114 156 102 156 51 1.0 3.000 365 2580 0.12 2 3/sx21/2 4.63 6.00 4.13 6.13 2.00 2.1 0N65 76.1 2517 11476 3.05 M10x63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 1 ¼x2½ 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 M10x63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 3/8 X2½ 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 M10x63 152 J 200 143 191 54 1.3 4.250 365 5178 0.17 2 3/8 X2'/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 1 M10x63 152 1.87 137 187 54 1.4 5 5.563 365 8872 0.17 1 ½ x 3 725 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 M12x76 184 235 171 232 57 2.3 5.250 365 7901 0.17 '/2x3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 M12x76 168 229 162 229 57 2.2 5.500 365 8672 0.17 1 '/2X3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 4 M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 ½X3'/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 1683 2517 44469 4.32 2 1 M12x83 213 264 1 200 257 57 2.7 6.250 365 11198 0.17 ½x3¼ 7.88 10.00 738 9.88 2.25 5.6 159.0 2517 49753 432 2 M12x83 200 254 187 251 57 2.5 6.500 365 12112 0.17 ½x3¼ 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 M12x83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 1 5/ex4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94863 432 M16x 101 276 340 260 333 64 5.2 8.500 365 20712 0.17 5/8 X4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 1 M16x 101 270 337 1 260 257 67 5.2 10 10.750 300 27229 0.25 7/8 X6½ 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 M22x165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 1 7/8X6½ 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.4 M22 x 165 406 483 394 486 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or con:raction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Cry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade 'E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 i'(ctau1 ic victaulic.com 4.1 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Style 109 Pre-Assembled Style 109 Joint Assembled Size Maximum Maximum Pipe End - Bolt/Nut Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Separation Approx. YL - YB - X Z - YL YB X Z Nominal Diameter Pressure4 Load4 Allowable5 Qty. Size (Each) inches inches psi lb inches inches inches inches inches inches inches inches inches inches lb mm Minn kPa N mm mm mm mm mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 1 3/8X2V4 1.88 2.50 3.13 1.88 1.88 2.63 2.75 1.88 1.4 DN32 42.4 2517 3514 2.54 M10x57 48 64 79 48 48 67 70 48 0.6 1½ 1.900 365 1035 0.10 1 3/8x2' /4 2.00 2.63 3.25 1.88 2.00 2.75 3.00 1.88 1.5 DN40 48.3 2517 4604 2.54 M10x57 51 67 83 48 51 70 76 48 0.7 2 2.375 365 1616 0.12 1 3/8 X2½ 2.25 2.88 3.88 2.00 2.25 3.13 3.50 2.00 1.8 DNSO 603 2517 7193 3.05 M10x63 57 73 98 51 57 79 89 51 0.8 2½ 2.875 365 2370 0.12 1 'Is x2½ 2.50 1 3.13 4.38 2.00 2.50 3.38 3.88 2.00 2.1 73.0 2517 10542 3.05 M10x63 64 79 1 111 51 64 86 98 51 0.9 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets and cannot be used with the Style 009N or Style 109 couplings. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victáulic.com 4 \4tauhcr 5.0 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM" VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 365 365 363 363 363 363 11/4 DN32 1.660 42.4 2517 2517 2503 2503 2500 2500 25 25 1 25 25 25 25 365 365 363 363 363 363 11/2 DN40 i48.3 c 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 2 DN5O 2375 603 2517 2517 2503 2500 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 2½ 2.875 2517 2517 2503 2500 2500 2500 73.0 365 363' 363 363 DN65 1: 73;000 2517 N/A 25038 2500 2500 N/A 25 25' 25 25 365 365 363 363 363 363 3 3.500 DN80 88.9 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 4 4.500 DNiOO 1 2517 2517 2503 2503 2500 2500 . 25 25 25 25 25 25 363 363 4.250 N/A N/A 2503 2503 N/A N/A 80 25 25 290 365 363 363 232 363 5 563 2000 2517 2503 2503 1600 2500 141.3 20 25 25 25 16 25 5 250 3638 133.0 N/A N/A 25038 N/A N/A N/A 25 290' 3638 232 363 DN125 500 2000 N/A 25038 N/A 1600 2500 139.7 20' 258 25 25 300 365 363 363 232 363 6 6.625 DN150 168.3 2068 2517 2503 2503 1600 2500 20 25 257 25 16 25 3638 6.250 N/A N/A 25038 N/A N/A N/A 159.0 25 29010 3638 363 6.500 200010 N/A 25038 N/A N/A 2500 165.1 20 258 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual I-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 102204.0mm pipe wall. '° cULus listed for EN 10255 4.5 mm pipe wall. ' With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the erd face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 5 \)tauIiice victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus" FM" VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 300 365 363 363 232 363 1692 2068 2517 2503 2503 1600 2500 DN200 20 25 25 25 16 25 290 3638 8.500 2000 N/A 25038 N/A N/A N/A 216.0 20 25 300 300 300 300 10 10.750 2068 2068 2068 2068 N/A N/A DN250 20 20 20 20 30012 300 250 300 12 12.750 206812 2068 1720 2068 N/A N/A N300 323.9 2012 25 17 1 20 6 Listed/Approved for Continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. ° cULus listed for EN 102204.0mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 cUL listed to 250 psi/1720 kPa /17 bar. 5.1 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals13 The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM________________ Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi inches inches kPa kPa kPa kPa DIN mm bar bar bar bar 365 365 365 365 2517 2517 2517 2517 DN32 • 25 25 25 25 365 365 365 365 1 ½ 1.900 DN40 483 2517 2517 2517 2517 25 25 25 25 365 365 365 365 2 DN5O 2.375 2517 2517 2517 2517 25 25 25 1 -.-. 25 365 365 365 365 21/2 2.875 3.0 2517 2517 2517 2517 25 25 25 25 13 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems .40° F/C and above. Please see the Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com Jtaukcr victaulic.com 5.2 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM psi psi inches kPa kPa Pipe Type DN bar bar 1¼-4 300 EF 0N32—DN100 2068 N/A 20 300 300 EL 2068 2068 DN32—DN50 20 20 300 ET40 2068 N/A DN32—DN50 20 300 EZF 3-4 2068 N/A DN80—DN100 20 300 300 EZr 2068 2068 DN32—DN50 20, 20 300 FF 1 1/2-4 2068 N/A DN4O—DN1'DO 20 300 300 GL 2068 2068 DN32—DN5O 300 300 DN32— DIN 100 2068 2068 20 20 IMF 175 175 6 DN150 15 1205 12 12 300 300 MT 2068 2068 DN32—DN50 20 20 300 MLT DN32—DN50 N/A 2068 20 300 IF 21/2-4 N/A 2068 730 20 175 300 WG5,WG5E,WF5,WG7,WG7E,WL7 1205 2068 DN32— DIN 100 20 300 300 WLS 2068 2068 DN32—DN50 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFlow 5 steel pipe manufactured by Wuppermann Stahl GmbH. WGJ, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 7 \4taulic 8 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com \4taulic victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM inches psi psi kPa kPa Pipe Type DIN bar bar 300 1 1/4 _2 1/2 N/A 2068 DN32 —73.0mm 20 EF 300 2 2068 N/A DN40— mm 20 300 Easy-Flow N/A 2068 DN32—DN50 20 300 EL N/A 2068 0N32—DN50 20 300 300 E140 2068 2068 DN32—DN50 20 20 300 lh/4 2 N/A 2068 0N32 - DN50 20 EZT 300 1 1/2-2 2068 N/A DN40—DN50 300 300 FF 2068 2068 DN40-73.0mm 20 20 300 GL N/A 2068 DN32—DN50 300 300 IMF 114-2'/2 2068 2068 DN32 —73.0mm 20 20 300 300 MT 1/4-2 2068 2068 0N32—DN50 20 20 300 300 MILT 1 2068 2068 DN32—DN50 20 20 300 TF 2½ N/A 2068 73.0 mm -- 300 WG7, WG7E 0N32—DN50 N/A 2068 20 300 WLS DN32—DNSO N/A 2068 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT = MILT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. victaulic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of Q any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 25,01; Original Groove System (OGS) Groove Specifications I-009N: Installation Instructions FireLock EZTM Rigid Coupling Style 009N -100; Victaulic Field Installation Handbook 1-109: Installation Instructions FireLockM One-Bolt Rigid Coupling Style 109 l-ENDCAP: Victaulic End Caps Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.64 7072 Rev M Updated 12/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 01 \ Ac- t _au i-id FireLock® Rigid Coupling Style 005H with Vic-PIusTM Gasket System oI Patented Exaggerated for clarity tn PIuS et System Approvals/Listings: USTED 104-la/02 See Victaulic Publication 10.01 for more details. [PC and VdS Approved, see notes on page 3 Product Description: FireLock Style 005H rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005H FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-Plus°" Gasket System: Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Job/Owner System No. I Location I Contractor Submitted By Date 4tauhcr 10.02 Material Specifications: Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Standard: Orange enamel (North America); red enamel (Europe) 0 Optional: Hot dipped galvanized Coupling Gasket: (specify choice) NOTE Additional gasket styles are available. Contact Victaulic for details. 0 Grade "E" EPDM Type A VicPlusr Gasket System' EPDM (Violet color code). FireLock products have been Listed by underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade °E" Type A Vic-Plus" Gasket System, requiring no field lubrication for most installation conditions. 0 Grade "L" silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade 'E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. I Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on 'typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 10.02 1538 Rev M updated 10/2014 © 2014 Victaulic Company. All rights reserved. 1 ictaulic victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Dimensions: Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 ¼ - 4/32 - 100 mm sizes and 300 psi /2068 kPa for 4 1/4 - 8/108 - 200 mm sizes; Schedule 10 roll grooved or 0 Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular deflection. Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End Dimensions __________ Weight X V Z Size Diameter Pressure 14 Load' Separation2 Bolt/Nut' Each inches inches psi lbs. inches No- size inches inches inches lbs. mm mm kPa N mm inches mm mm mm kg 1 1/4 1.660 350 755 0.05 2 -3/8 X21/4 2.75 4.50 1.88 1.2 32 42.4 2413 3370 1.2 70 114 48 0.5 1 1/2 1.900 350 990 0.05 2-3/8 x21/4 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 76 121 48 0.5 2 2.375 350 1550 0.07 2-3/,x2½ 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 89 133 48 0.7 21/2 2.875 350 2270 0.07 2- /,x2Y2 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 102 146 48 .09 76.1 mm 3.000 3.000 350 2475 0.07 4.13 5.75 1.88 1.9 76.1 2413 11010 1.7 105 146 48 0.9 3 3.500 350 3365 0.07 2-/, x 21/2 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 118 156 48 1.0 4 4.500 350 5565 0.16 2-/, x 21/2 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 146 184 54 1.4 108.0mm 4.250 300 4255 0.16 5.63 7.25 2.13 3.1 108.0 2068 18940 4.1 2-3/8 X2½143 184 54 1.4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2-1/2 x3 175 229 54 2.0 133.0 mm 5.250 300 6495 0.16 2-½x23% 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 168 229 54 2.0 139.7 mm 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 2-1/2 x23/4 175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 2-1/2 x3 203 254 53 2.3 159.0 mm 6.250 300 9200 0.16 2-½X23/4 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 54 2.5 165.1 mm 6.500 300 9955 0.16 2- ½ x 3 8.15 10.00 2.13 5.5 165.1 2068 44295 4.1 207 1 254 54 2.5 8 8.625 300 17525 0.19 2-'/,x 41/4 10.50 1 13.14 2.63 11.3 200 1 219.1 1 2068 78000 4.8 267 334 67 5.1 1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only. Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and LPC Approved to 16 Bar/235 psi. 10.02 1538 Rev M Updated 10/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 jtauIic victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Listings/Approvals: The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure psi Related Working Pressure psi Related Working Pressure psi Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM Pipe Sch. Size inches UL ULC FM 5 U/43 175 175 175 EL 11/4 2 300 N/A N/A MT 11/4-2 300 N/A N/A 11/4 -3 350 350 350 ET 11/4_2 300 N/A N/A STF 11/4_4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 3006 N/A 300 Steady11/4 -2 N/A N/A 300 BLT 11/4-2 300 300 N/A FF 11/4-4 N/A N/A 300 IF 3-8 N/A N/A 300 DF 11/4 -4 300 300 300 GAL -7 11/4-2 300 N/A N/A WLS 11/4 -2 300 300 N/A DT 11/4 -2 300 300 N/A MILT 1¼-2 300 N/A N/A XL 11/4 -3 1 300 300 300 EF 11/4 -4 1757 N/A 175 MF 11/4 -4 1 300 N/A 300 5 FM approved for service in 11/2 -4' pipe. 6 UL Listed for service up to 4 pipe only. 7 UL Listed for service up to 3 only. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shalt be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in POE format Victaulic reserves the right to charge product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaalic° is a registered trademark of Victaulic Company. 10.02 1538 Rev M updated 10/2014 © 2014 Victaulic Corn Dany. All rights reserved. victaulic.com 3 \4taulicr Victaulic® Flexible Coupling A_r_ —ta -U1 - C Style 75 06.05 1.0 PRODUCT DESCRIPTION Available Sizes 1 - 8/DN25 - DN200 Pipe Material Carbon steel Stainless steel Maximum Working Pressure Accommodates presswes ranging from full vacuum (29.9 in Hg/760mm Hg) up to 500 psi/3447 kPaI34 bar Working pressure dependent on material, wall thickness and size of pipe Application Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories Provides a flexible pipe joint which allows for expansion, contraction and deflection Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS -- NOTES Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. See publication 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. 1 \,,LtEIIUIIC victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) O Standard: Orange enamel El Optional: Hot dipped galvanized 0 Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') El Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. 0 Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range —20"F to +180"F/-29"C to +82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140°F/+600C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. I Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) 0 Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FES, finish Type Ill (imperial) or Type II (metric). Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593; Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.om 2 's.J(t _au Iic victaulic.com 4.0 DIMENSIONS Style 75 Pipe End Deflection from Size Separation3 Centerline3 Bolt/Nut - Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X V Z (Each) inches inches inches inches/ft. imperial inches inches inches lb ON mm mm Degrees mm/rn - metric mm mm mm kg 1 1.315 0-0.06 2 -43' 0.57 2 %x2 2.38 4.27 1.77 1.3 DN25 1 33.7 0-1.6 48 1 - M10x51 61 108 45 0.6 1 1/4 1.660 0-0.06 0.45 2 ¼x2 2.68 4.61 1.77 1.4 0N32 42.4 0-1.6 2 - 10' 38 M10x51 68 117 45 0.6 1 1/2 1.900 0-0.06 1 56' 0.40 2 %x2 2.91 4.82 1.77 1.5 DN40 48.3 0-1.6 - 33 - M10x51 74 122 45 0.6 2 2.375 0-0.06 1 1 - 3 032 2 ¼x2 3.43 5.22 1.88 1.7 DN50 60.3 0-1.6 26 M10x51 87 133 48 0.8 21/2 2.875 0-0.06 1 - 15' 0.26 2 3/8 X2 3.88 -1.88 1.9 - 73.0 0-1.6 22 M10x51 98 144 48 0.9 3.000 0-0.06 1 - 12' 0.26 2 %x2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 M10x51 102 150 48 0.9 3 3.500 0-0.06 1 - 2' 0.22 2 ½x23/4 4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 18 M12x70 114 178 48 1.3 31/2 4.000 0-0.06 0 54' 0.19 2 ½ x 2/4 5.00 7.50 1.88 2.9 DN90 101.6 0-1.6 - 16 M12x70 127 191 48 1.3 4 4.500 0-0. - 13 1 36' 034 2 ½X2 3/4 5.80 8.03 2.13 4.1 DN100 1143 0-3.2 28 M12x70 147 204 54 1.9 4.250 0-0.13 1 - 41' 035 2 ½x23/4 5.55 7.79 2.13 3.7 108.0 0-32 29 M12x70 141 198 54 1.7 5.000 0-0.13 1 26' 025 2 ¼X3Y4 6.13 9.43 2.13 5.5 127.0 0-3.2 21 M16x83 156 240 54 2.5 5 5.563 0-0.13 1 18' 0.27 2 ¼x3'/4 6.88 10.07 2.13 5.8 141.3 0-3.2 23 - - M16x83 175 256 54 2.6 5.250 0-0. - 13 1 21' 028 2 5/8X3¼ 6.55 9.37 2.13 6.0 133.0 0-3.2 - 24 - M16x83 166 238 54 2.7 5.500 0-0.13 1 - 18' 028 2 ¼ x 3¼ 6.80 9.59 2.13 6.3 0N125 139.7 0-3.2 24 M16x83 173 244 54 2.9 6.000 0-0.13 1 - 12' 021 2 %x3¼ 7.38 10.48 1.88 6.2 152.4 0-3.2 18 - M16x83 187 266 48 2.8 6 6.625 0-0.13 1 0.23 2 5/sx3¼ 8.00 11.07 2.13 7.0 DN150 168.3 0-3.2 18 - M16x83 203 281 54 3.2 6.250 0-0.13 1 9' 0.24 2 5/8x3¼ 7.63 10.49 2.13 6.8 159.0 0-3.2 20 - M16x83 194 266 54 3.1 6.500 0-0.13 1 - 7' 0.23 2 ¼x3¼ 7.84 10.66 2.08 6.6 165.1 - 0-3.2 58 M16x83 199 271 53 3.0 8.515 0-0.13 0 51' 0.18 2 3.4X4 1/4 10.19 13.75 2.32 13.2 216.3 0-3.2 - 46 - M20 108 259 350 59 6.0 8 8.625 0-0.13 0 - 50' 0.18 2 3/4X4¼ 10.34 13.97 2.13 12.4 DN200 219.1 0-3.2 14 - M20x108 263 355 59 5.6 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 1/4 -3 1h*/DN20 - DN90; 25% for 47DN 100 and larger. NOTE Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 3 Ais-tauhcr victaulic.com 5.0 PERFORMANCE Style 75 Size Maximum Actual Outside Working Maximum Nominal Diameter Pressure4 End Load4 inches inches psi lb DN mm kPa N 1 1.315 500 680 DN25 33.7 3447 3,025 1 ¼ 1.660 500 1080 DN32 42.4 3447 4,805 1 ½ 1.900 500 1420 DN40 483 3447 6,320 2 2.375 500 2215 DNSO 60.3 3447 9,860 21/2 2.875 500 3245 73.0 3447 14,440 3.000 500 3535 DN65 76.1 3447 15,730 3 3.500 500 4800 DN80 88.9 3447 21,360 31/2 4.000 500 6300 DN90 101.6 3447 28,035 - 4 4.500 500 7950 DN100 114.3 -- 3447 35,380 4.250 450 6380 108.0 3103 28,395 5.000 450 8820 127.0 3103 39,250 5 5.563 450 10935 141.3 3103 48,660 5.250 450 9735 133.0 3103 43,325 5.500 450 10665 0N125 139.7 3103 47,460 6.000 450 12735 152.4 3103 56,670 6 6.625 450 15525 DN150 168.3 3103 69,085 6.250 450 13800 159.0 3103 61,405 6.500 450 14930 165.1 3103 66,412 8.515 450 25625 216.3 3103 113,986 8 8.625 450 26280 DN200 219.1 3103 116,945 Working Pressure and End Load are total, from all internal and external loads, based on ANSI B36.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4 Ais—taul—icr victaulic.com 6.0 NOTIFICATIONS WARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS 02.06 Victaulicll Potable Water Approvals ANSI/NSF 05.01: Victaulic® Seal Selection Guide - Elastomeric Seal Construction 06.15: Victaulic® Pressure Ratings and End Loads for Victaulic Couplings on Steel Pipe 1001: Victaulic® Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01: Victaulic® Pine Preparation for Use on Stainless Steel Pine With Victaulic Products 17,09: Victaulic® Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pine 25.01: Victaulic® Standard Groove Specifications 26.01: Victaulic® Design Data 29.01: Victaulic® Terms and Conditions of Sale -100: Victaulic® Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, is accordance with industry standards and project specifications, anc the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other locument, nor any verbal recommendation. advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use stony material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products lobe installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. Warranty Refer to the Warranty section at the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.05 1470 Rev P Updated 10/2017 tO 2017 Victaulic Company. All rights reserved. victaulic.com JtaUIiC victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric to El E to E - 9 n~ No. 50 No. 51 M-EtoE-+1 +-EtoE 1:::]~ - Fabricated Steel Fabricated Steel No. 50 ND.51 E ltoE E to E -1 - E to E -+ r'- [to E No. 50 No. 51 Fabricated Steel Fabricated Steel No. 50 No. 51 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb ON mm kg mm kg 1¼ 3/4 1.9 DN32 DN20 + 'I 09 - - 1.9 1 DN25 + 0.9 - - 1½ 3/4 1.4 DN40 DN20 + 0.6 - - 1 2.50 0.8 8.50 (sw) 4.5 DN25 64 0.4 216 2.0 11/4 2.50 1.0 DN32 64 0.5 - - 2 3/4 2.50 1 0.9 9.00 (sw) 2.0 DN5O DN20 64 0.3 229 0.9 1 2.50 0.7 9.00 (sw) 2.3 DN25 64 0.3 229 1.0 11/4 2.50 1.2 9.00 (sw) 4.6 DN32 64 1 0.5 229 2.1 11/2 2.50 1.0 3.50 1.1 DN40 64 0.5 89 0.5 21/2 3/4 13 3.3 DN20 + 0.6 + 1.5 2.50 1.1 9.50 3.5 1 DN25 64 0.5 241 1.6 11/4 3.50 3.3 3.50 1.4 DN32 89 1.5 89 0.6 11/2 2.50 3.6 9.50 (sw) 3.7 DN40 64 1.6 241 1.7 2 2.50 3.9 3.50 43 0N50 64 1.8 89 -. 2.0 3 1/4 1.5 4.5 DN80 DN20 + 0.7 + - 2.0 1 2.50 1.3 9.50 (sw) 4.8 DN25 64 0.6 241 1 2.2 11/4 2.50 1.4 4.8 DN32 64 0.6 + 2.2 11/2 2.50 5.1 9.50 (sw) 5.1 DN40 64 2.3 241 2.3 2 2.50 1.6 3.50 6.0 DN50 64 0.7 89 2.7 21/2 2.50 1.8 3.50 7.0 64 0.8 89 3.2 DN65 2.50 2.1 64 1.0 31/2 3 2.50 2.0 9.50 (sw) 7.0 DN90 DN80 64 0.9 241 3.2 4 1 3.00 3.0 13.00 (sw) 6.5 DN100 DN25 76 1.4 1 330 1 2.9 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb ON mm kg mm kg 11/4 4.6 0N32 + 2.1 - - 11/2 3.00 (sw) 2.6 10.00 (sw) 8.1 DN40 76 1.2 254 3.7 2 3.00 2.4 4.00 3.3 DN50 76 1.1 102 1.5 21/2 3.00 2.7 4.00 3.4 76 1.2 102 1.5 3 300 3.2 4.00 3.5 DN80 76 1.4 102 1.6 31/2 3.00 2.9 10.00 (sw) 8.0 -- - DN90 - 76 1.3 254 3.6 5 2 11.00 (sw) 9.0 11.00 (sw) 5.2 DNSO 279 4.1 279 2.4 2/2 4.00 4.3 11.00 (sw) 10.8 102 2.0 279 4.9 3 4.00 5.5 11.00 (sw) 11.1 DNSO 102 2.5 279 5.0 4 3.50 4.3 5.00 12.0 DN100 89 1.9 127 5.4 6 1 4.00 5.0 11.50 (sw) 14.5 DN150 0N25 102 2.3 292 6.6 P12 5.5 DN40 + 2.5 + + 2 4.00 6.6 11.50 (sw) 14.5 DNSO 102 3.0 292 6.6 21/2 4.00 6.4 11.50 (sw) 14.2 102 2.9 292 6.4 3 4.00 6.4 5.50 15.0 DN80 102 2.9 140 6.8 4 4.00 6.5 5.50 17.0 DN100 102 2.9 140 7.7 - 5 4.00 6.4 5.50 17.0 102 2.9 140 7.7 8 21/2 16.00 7.9 12.00 (sw) 26.1 DN200 406 3.6 305 11.8 3 5.00 9.3 12.00 (sw) 22.0 DNSO 127 4.2 305 10.0 4 5.00 10.4 12.00 (sw) 23.0 DN100 127 4.8 305 10.4 5 5.00 11.6 12.00 (sw) 23.0 127 5.2 305 10.4 6 5.00 11.9 6.00 24.0 DN150 127 5.4 152 10.9 07.01 1449 Rev AF Updated 08/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 21 j$'tauIic Victaulic® Reducing Coupling A tlUIiC Style 750 06.08 1.0 PRODUCT DESCRIPTION Available Sizes: 2 x 1 through 10 x 8'/DN50 x DN25 through DN250 x DN200 Pipe Material: Carbon steel Maximum Working Pressure: Up to 500 psi/3447 kPa Working pressure dependent on material, wall thickness and size of pipe Application: Joins OGS roll grooved and cut grooved pipe, as well as OGS grooved fittings, valves and accessories Permits direct reduction on piping run Optional steel washer prevents telescoping of the smaller pipe inside the larger pipe during vertical system assembly Pipe Preparation: Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications. 2.0 CERTIFICATION/LISTINGS NOTES o Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 06.08 1536 Rev L Updated 10/2017 © 2017 Victaulic Company. All rights reserved. 1 4'tauIIc victaulic.cnm 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Standard: Orange enamel. Optional: Hot dipped galvanized conforming to ASTM A153. Optional: Contact Victaulic with your requirements. Gasket: (specify choice') El Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30"F to +230"F/-34"C to +110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+820C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. El Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range —20"F to +180"F/-29"C to +82"C. May be specified for petroleum products, hydrocarbons, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140°F/+60°C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Others El For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide. I Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts (specify choice2): D Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FES, finish Type Ill (imperial) or Type II (metric). 0 Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Assembly Washer (optional): Galvanized carbon steel. 2 Optional bolts/nuts are available in imperial size only 06.08 1536 Rev L Updated 10/2017 © 2017 Victaulic company. All rights reserved. victaulic.com ,4 _tau I ic victaulic.com 4.0 DIMENSIONS Style 750 I IINN INN =1 Pipe End Size Separation2 Deflect. From CL3 Bolt/Nut Dimensions Weight Approximate Nominal Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches lnjFt. inches inches inches inches lb DN mm Degrees mm/rn - mm mm mm mm kg 2 1 0-0.07 0.20 3.38 5.28 1.88 2.7 0 57 2 3/8 x 2 DN50 DN25 0-1.8., 17 85 134 48 1.2 11/2 0-0.07 0.20 3.38 5.28 1.88 2.0 DN4O 0-1.8' 0 57 17 2 /8 x 2 85 134 48 1.0 21/2 2 0-0.07 0.16 4.00 5.93 1.88 3.1 0 -47 2 3/s x 2 DN50 0-1.8 14 102 151 48 1.4 2 0-0.07 0.6 4.38 6.63 1.88 4.6 0 47 2 DN65 DN50 0-1.8 14 ½ x 21/4 111 168 48 2.1 3 2 0-0.07 0.13 4.75 7.13 1.88 4.9 -39 2 ½ x 2~ DN80 DN50 0-1.8 ]0* 11 121 181 48 2.2 2½ 0-0.07 0.13 4.75 7.13 1.88 4.3 -39 2 ½ x2~ 0-1.8 11 121 181 48 2.0 0-0.07 • 0.13 4.75 7.13 1.88 4.2 0-39 2 1/2 x 2.4 DN65 0-1.8 11 121 181 48 1.9 4 2 0-0.13 0.28 6.25 8.90 2.25 8.1 1 -19 2 ½ x 3¼ DN100 DN50 0-3.2 25 159 226 57 3.7 21/2 0-0.13 0.28 6.25 8.90 2.25 8.6 1 -19 2 5/ x 3¼ 0-3.2 25 159 226 57 3.9 0-0.13 0.28 6.25 8.90 2.25 6.9 lo-191 2 ½ x 31/4 DN65 0-3.2 25 159 226 57 3.1 3 0-0.13 0.28 6.00 8.90 2.25 6.7 1 -19 2 /8 x 31/4 DN80 - 0-3.2 25 152 226 57 3.0 5 4 0-0.13 0.22 7.18 10.70 2.13 11.2 1 -3 2 3/4 x 4¼ DN100 0-3.2 19 182 272 54 5.1 4 0-0.13 0.19 8.63 11.90 2:25 15.2 o 2 3/4 x 4¼ 165.1 DN100 0-3.2 16 219 302 57 6.9 6 4 0-0.13 0.18 8.63 11.90 2.25 16.7 0 -52 2 3/4 x 4¼ DN150 DN100 0-3.2 15 219 302 57 7.6 5 0-0.13 0.18 8.31 11.90 2.25 12.9 0'- 52 2 3/4 X41/4 0-3.2 15 211 302 57 5.9 8 0-0.13 0.13 10.75 14.88 2.50 23.2 0 -38 7/a x DN200 165.1 0-3.2! 11 1 2 273 378 64 10.5 6 0-0.13 , 0.13 10.81 14.88 2.50 22.4 2 /8 X DN150 3.2_ 275 _378 64 1 10.2 10 8 0-0.13 0.90 13.12 17.26 2.62 31.4 0 -25 2 0N250 DN200 0-3.2 8 1 x 5½333 438 1 67 14.2 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes, these figures should be reduced by: 50% for 3%_3 W/DN20 - DN90; and 25% for 4/DN100 and larger. NOTE Metric thread size bolts are avaialble (colord-coded gold) for all coupling sizes upon request. Contact Victaulic for details. 06.08 1536 Rev L Updated 10/207 © 2017 Victaulic Company. All rights reserved. victaulic.com JtaU1ic victaulic.com 5.0 PERFORMANCE Style 750 Size Maximum Working Maximum End Nominal Pressure4 Load4 inches psi lb DN kPa N 2 1 350 500 0N50 DN25 2413 2,225 350 1000 1½ DN40 2413 4,450 21/2 2 500 2215 DNSO 3447 9,850 2 350 1550 DN65 DN50 2413 6,900 3 2 350 1550 DN80 DN50 2413 6,900 500 3250 21/2 3447 14,460 350 2475 DN65 2413 11,010 4 2 350 1550 DN100 DNSO 2413 6,900 350 2275 2½ 2413 10,125 350 2475 DN65 2413 11,014 500 4810 3 DN80 3447 21,400 5 4 350 5565 DN100 2413 24,765 6 4 350 5565 DN150 x DN100 2413 24,765 350 8500 5 2413 37,825 8 350 11610 DN200 x 165.1 2413 51,645 350 12060 6 - DN150 2413 53,645 10 8 350 20450 DN250 x DN200 2413 90,970 Working Presssure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe and material. Maximum working pressure rating based on larger pipe size. Maximum end load rating based on smaller pipe size. NOTES WARNING: FOR ONE-TIME FIELD USE ONLY, the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown. For joint pressure ratings on additional carbon steel wall thicknesses, see publication 06.15. 06.08 1536 Rev L Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com X 0 A~c tauIic• victaulic.com 5.1 PERFORMANCE Flow Data - Head Loss Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water flowing at +60°F/+16°C. Flow Reducing Flow Expanding Equivalent Size Pipe Length Small Nominal Diameter inches ft DN m 2 1 5.9 DN50 DN25 1.8 2.0 1½ DN4O 0.6 2½ 2 1.9 DN50 0.6 2 1.9 DN65 DN50 0.6 3 2 5.5 DN80 _2!. 1.7 3.8 2½ 1.2 3.8 0N65 1.2 4 2 6.0 DN100 .!!52. 1.8 6.0 2½ 18 60 DN65 1.8 6.0 3 DNSO 1.8 5 4 3.0 DN100 0.9 4 6.0 165.1 DN100 1.8 6 4 6.0 DN150 DN100 1.8 4.5 5 1.4 8 7.3 DN200 165.1 2.2 7.3 6 DN15O 2.2 10 8 8.7 DN250 DN200 2.7 Equivalent Size Pipe Length Small Nominal Diameter inches ft DN m 1 2 2.7 DN25 DN50 0.8 1½ 2 1.9 DN40 DN50 0.6 2 1.0 DN50 x 2½ 0.3 1.0 DN65 0.3 3.5 3 DN8O 1.1 3.0 4 DN100 0.9 2½ 3 2.5 DN8O 0.8 3.0 4 DN100 0.9 3 2.5 0N65 DN80 0.8 3.0 4 DN100 0.9 3 4 2.5 DN80 DN100 0.8 4 5 3.3 DN100 1.0 4.6 165.1 1.4 4.6 6 DN1SO 1.4 5 6 2.3 DN15O 0.7 8 5.4 165.1 x DN200 1.7 - 6 8 6.0 DN150 0N200 1.8 8 10 6.3 DN200 x DN250 1.9 06.08 1536 Rev L updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com -IuAic--ta-ulicr victaulic.com 6.0 NOTIFICATIONS A WARNING ONE Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Only No. 61 bull plugs shall be used with Style 750 reducing couplings in systems where a vacuum may develop. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS 05.01 Victaulic® Seal Selection Guide 10.01: Victaulic® Products for Fire Protection Pining Systems - Regulatory Approval Reference Guide 25.01: Victaulic® Original Groove System (OGS) Groove Specifications 26.01: Victaulic® Design Data 29.01: Victaulic® Terms and Conditions of Sale 400: Victaulic® Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property night of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the night to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks on registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/on other countries. 06.08 1536 Rev L Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com J1tSlUIiC Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/-I-30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved Para___________ www.victaulic.com vlclAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 vlclAuuc COMPANY. ALL RIGHTS RESERVED. REV-0 \,4tauIic 11.021 DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at an' location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Style ~Max. ork~ Approx. size Pressure@ TA* X ½)a) 500 150 200 253 - 161 I 535 275 31 920N 50 1 5 - 3450 38.1 51 64 41 136 70 15 3/4 (a) 0 920N 500 1.50 197 2.53 1.61 5.35 2.75 3.1 20 3450 381 50 64 - 41 136 70 1.5 - 1(a) a 920N 500 150 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 381 47 64 - 41 136 70 1.4 - 1¼ (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 445 52 70 79 41 136 83 17 1.5 2½ x ½ (a) §o 920N 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 381 56 70 - 46 143 70 1 14 - Y4 (a) §0 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §0920N 500 1.50 206 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 1¼ t (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 111 t (a) a 92014 500 2.00 2.28 300 325 1.82 626 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1,6 ½ (a) 76.1 x 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 1.8 1/4 (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1(a) 920N 300 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 11/4 (a) 0 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 1 76 84 49 1 160 76 1 1.6 1.5 11/2 (a) D 920N 500 2.00 228 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 1/2 (a) o 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1,6 - N (a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 920N 500 1,50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 381 61 78 - 58 156 70 16 - 1¼ (a) t 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 I 3.7 32 )b) 1.8 [1.8 11/2 (a) to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a) a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 1 4.6 50 3450 63.5 70 89 90 58 172 99 23 2.1 31/2 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 I 3.8 50 3450 1 63.5 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21h' BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vIcTAULIc COMPANY. 02018 VIcTAuUc COMPANY ALL RIGHTS RESERVED. 11.02_2 or- tIIUIiC REV_O DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seat Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available or use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Style Max. Work Approx. Size No- sure@ Dimensions Weight Each Nominal Size 920 W TABLE CONTINUED FROM PAGE 2 4 ½ (a) 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 - 100 15 3450 38.1 77 90 68 178 70 1.8 - 3,4 (a) a 500 1.50 3.00 3.56 - 2.69 7.01 2.75 3.7 - 20 3450 38.1 76 90 - 68 178 70 1.8 1(a) a 020N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 11/4 (a) to 920N 500 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2 (a) ta 520N 500 2.00 3.28 4.00 4.00 2.69 7.01 3,25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 1 2.1 21/2 (a) 3 920 500 275 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5 .0 65 3450 69.9 fl 102 102 68 186 118 Th fl 76.1 mm 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 29 3(a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 108.0 X 1l/(a)a 920N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 3450 44.5 78 96 67 194 78 2.3 1 1h (a)a 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 - 67 194 83 2.3 2 (a( 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 288 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1 1/2 (a) 3 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 508 102 121 121 80 246 94 34 3.4 2 (a) t 920 500 2.50 4.00 4.75 4,75 3.16 9.70 4.38 8.2 8.0 50 3450 615 102 121 121 -80 6 111 3.7 36 2½ (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 36 76.1 mm n 920 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 _ 3450 699 95 121 80 246 118 36 3(a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 1330 x 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 3450 63.5 95 114 81 203 ....22...... 3.6 ..... 920 500 3.50 3.81 5.00 [ 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 1 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for File Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify 8SPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for Fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com taulie vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-0 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1h'750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. size Style M a X. Work Approx. No. ~Pre ss ure@ Dimensions Weight Each TABLE CONTINUED FROM PAGE 1397 x 1½t 920N 500 200 378 1 450 330 823 3.25 70 40 3450 508 96 114 - 84 209 83 3.2 2 i 920N 500 2.50 3.75 4.50 3.30 8.23 388 9.0 50 3450 63.5 95 114 - 84 209 99 41 - 6 x 1¼ (a) 920N 500 1.75 4.43 5.13 5.13 3,79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1½ (a) to 920N 500 200 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2 ½ 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 1 3.4 761 mm c 920 500 2.75 4.15 5.21 3.69 10.51 463 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 37(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) tu 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 0 1143 97 146 137 94 267 159 46 4.6 1590 x 11/2 (a) 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 j - 92 239 83 3.5 - 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 239 99 3.6 - 761 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 699 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 37 6.4 1080mm 920 500 4.50 4.45 - 538 3.63 9.40 612 10.0 __- 3,150 114.3 j_ 137 92 239 j55 _ 920 500 450 i 3.81 - 5.75 - - 3.63 - 9.40 6.25 18.0 100 I 3450 114.3 96.80 146 - 92 239 I 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ictaulice VIcTAULIc IS REGISTERED TRADEMARK OF vICTAuLIc COMPANY. 02018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.022 REV _O CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½0/50 x 15mm through 8 x 4/200 x 100 mm Max. Work Approx. Size Pressure@ Dimensions We ight Each mffi TABLE CONTINUED FROM PAGE 4 1 165.1 x 920N 500 1.50 3.88 ' 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 3.6 - 1 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - 1112 (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 54 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 1 6.0 50 3450 63.5 111 130 130 96 237 1 99 3.9 2.7 761 mm 920 500 2,75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a) t 0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 I 3450 88.9 110 140 130 92 267 135 4.6 3.8 4(a) to 920 500 4.50 3.81 5.75 538 3.63 1051 6.25 10.5 84 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 920 1 500 2.75 5.44 6.19 6.25 4.81 1242 4.50 11.6 11.6 >< 200 50 I 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2 (a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 1 5.3 5.3 761 mm 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 - 159 122 316 116 - 5.3 3(a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.viCtauliC.com viciuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-0 11.02_5 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. @ t Exaggerated for clarity Formulas for C,K. Values: = Q2 Where: ET Q = Flow (GPM) = Pressure Drop (psi) Q = C x C = Flow Coefficient = Where: Q = Flow (m3/hr) AP = Pressure Drop (Bar) Q = K x JAT K = Flow Coefficient Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe OUTLET SIZE ' Values V2 15 0.840 213 2 - 11 94 _Y4 20 1.050 26.7 - - 16 13.7 1 25 1.315 337 3 8 - 21 1.8 1¼ 32 1.660 42.7 5 /2 6 50 42.9 48 41.1 1 ½ 40 1.900 48.3 11 11 53 53 454 2 50 2.375 603 9 10 lb 112 96 104 89.1 21/2 65 2.875 73.0 20 121' 2 119 102 150 128.5 76.1 MM 3.000 16 - 161 - 76.1 138.1 80 3.500 88.9 14 15 /2 249 213.4 237 203.1 4.500 20 22 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1' FireLock Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 622018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. XA_i~cn_a _U, i 11.02 REV-0 I CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Nominal Size Outlet Size Actual Outside Pipe Approval Agency Rated Working Pressures - psi/kPa Vd, Size 21/2-6 Diameter 2.875 - 6.625 All 10 40 400 400 400 290 232 1 362 65-150 73.0- 168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875 - 4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 34 3040 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10 40 400 - 145 - 200 219.1 2755 - - 1000 8 8.625 34 10 300 - 250 - 145 - 200 219.1 2065 1724 1000 8 8.625 3,4 3040 300 300 145 - 200 219.1 2065 - 2065 - 1 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8°/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4'/100mm, 5'/125mm, 6/150mm and 8'7200 Trim diameter pipe. The Style 931 comes with a 21h'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 2018 VICTAUL C COMPANY. ALL RIGHTS RESERVED. REV-0 11 J A ~ s t _au I iC 11.027 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 vIcTAuuc COMPANY. ALL RIGHTS RESERVED. 11.02L Victaulic® FireLockTM Outlet-I jttauIic Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 1 1/4 -2 1/2"/DN32—DN65 Threaded Outlet Sizes: 1/2"/DN15, 3/4'/DN2O, and 1/DN25 NOTE IGS Grooved 1'/0N25 Outlets available for this product. See publication 10.54. Maximum Working Pressure 300 psi/2068 kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS E1 ILPCBI @' WM NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date ,rê,i .lie ian, 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. 1 X. Ai -C- t —SU I —ic r victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Orange enamel (North America, Latin America, Asia Pacific). El Red enamel (Europe). El Optional: Contact Victaulic with your requirements for other coatings. Gasket: El Grade EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines Only, It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: El Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). 10.52 3355 Rev H Updated 06/2018 © 2018 victauric Company. All rights reserved. victaulic.com 2 \,htlIUIIC victaulic.com 4.0 DIMENSIONS Style 922 • Style 922 Size Bolt/Nut - Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W V 7 (Each) inches inches inches inches inches inches inches inches lb ON mm - mm mm mm mm mm mm kg 1¼ 1/2 11 1.660 0.840 2 1 1.30 1.83 1.10 3.87 2.56 1 DN32 DN15 42.4 21.3 X 47 28 98 65 0.5 2 1 X 1 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 DN20 26.9 33 47 28 98 1 65 0.5 2 X 1 1.52 2.18 1.10 3.87 2.56 1 1 1.315 0N25 39 55 28 98 65 0.5 11/2 1/2 1.900 0.840 2 xit 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 36 50 31 104 65 0.5 2 X 1 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 DN20 26.9 36 50 31 104 65 0.5 2 %x il 1.64 2.30 1.22 4.08 2.56 1 1 1.315 0N25 33.7 42 58 31 104 65 0.6 2 1/2 2375 0.840 2 1xil 1.66 2.19 1.46 4.60 2.56 1 50 DN15 60.3 21.3 42 56 37 117 65 0.6 2 X 1 1.64 2.19 1.46 4.60 2.56 1 3/4 1.050 DN20 26.9 42 56 37 117 65 0.6 2 x1 1.88 2.54 1.46 4.60 2.56 2 1 1.315 DN25 1l. 48 65 37 117 65 0.7 21/2 1/2 2.875 0.840 2 x1 1.91 2.44 1.71 5.40 2.56 2 DN15 73.0 21.3 49 62 43 137 65 0.7 .. 1 1.89 2.44 1.71 5.40 2.56 2 3/4 1.050 0N20 26.9 48 62 43 137 65 0.7 2 X 1 - 2.13 2.79 1.71 5.40 2.56 2 1 1.315 0N25 54 71 43 137 65 0.7 0N65 1/2 3.000 0.840 1.91 2.44 1.71 5.50 2.56 2 DN15 76.1 21.3 2 49 62 43 140 65 0.7 ., X 1 1.89 2.44 1.71 5.50 2.56 2 3/4 1.050 DN20 ' 26.9 48 62 43 140 65 0.7 X1 2.13 2.79 1.71 5.50 2.56 2 1 1.315 0N25 33.712 54 -71 43 140 65 0.8 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com Jt _au Iic uigfiilir mm 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DIN meters meters 11/4 1 8.5 12.5 0N32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DNSO DN25 2.6 3.8 21/2 1 8.5 12.5 DN25 2.6 3.8 1 8.5 12.5 DN65 DN25 2.6 3.8 Hazen-Williams coefficient of friction is 120. 1 FireLockTM Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING 9 0 0 Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes 13(6 1'/4 30 32 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 '.41ttauIic. victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 1 Y4X½ 300 300 300 232 232 232 DN32XDN15 2068 t 2068 2068 1600 1600 1600 1 1/4X3/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1 1/4 X1 300 300 300 232 232 232 DN32XDN25 2068s 2068 2068 1600 1600 1600 1½x½ 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1 ½x1/4 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1½x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2x1/a 300 300 300 232 232 232 DN50XDN15 2068' 2068 1600 - 1600 1600 2x3/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1 300 300 300 232 232 232 DN50XDN25 2068J 2068 2068 1600 1600 1600 21/aX½ 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x1/4 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 - 1600 1600 300 232 232 232 DN65XDN25 2068 1600 1600 1600 - 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide 29.01: Victaulic Terms and Conditions of Sale -100: Installation Instructions 1-922: Installation Instructions FireLockTM Outlet-T User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendatior, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or offer intellectual property right. The terms "Patented" or 'Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on WeChat. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details, Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/sr its affiliated entities, in the U.S. and/or other countries. 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com \1ttaUlic Fire. Pq.c: QM .raJjqnaI www.anviistar.com RIT 0 MERIT® WeIdMiserTM Tee-Let® Welding Outlet Fittings Unified DesignTM Series b Merits Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit® Weld_MiserTM Tee-Lets® are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: - • The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. Each outlet size 11/2 and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are UL/ULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit® Weld-Miser1M Tee-Lets® are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify WeldMiserTM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI 131.20.1, or ISO-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® WeldMiserTM Tee-Let®. Method No. 2 Use the following system: - x Quantity Outlet Size Header Size I I Always Column 'A" Insert size order a few of Chart consolidation more than from Column actually "B" of chart. required for the job. Type Merit Steel Weight End Tee-Let Material I Sch. 10 A - Female Thread Standard B - Male Thread C - Cut Groove C/R - Roll Groove Method No. 1 Specify quantity desired followed by the part number shown in the "dimensions" chart for the type and size of outlet desired. Quantity Part Number —2— IñiLStar Fire Products Division WeIdMiserTM Tee-Let® Welding Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser1M Tee-Lee Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings spe- cifically designed and manufactured to be installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or 1S07/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria de- veloped for ASME B31 piping code. k~g APPROVED For listing/approval details contact your AnvilStar' Representative. TEE-LET IWELDED iOUTLET Outlet Model Outlet Pipe Size (Inch) Header Pipe Size (Inch) 1T1iiiiiui Rated Pressure (psig) Tee-Let Type A (F-Threaded End) 1/2,3/4,1 11/4,11,, 2, 2½, 3,4 1h8(Sch.10,40) 300 6 (EZ-Flow) ½ -4 (Sch. 5, DynaFlow) 2 4 (EZ-Flow) 2,4 Tee-Let Type C (Grooved End) 11/4 8 11/4 8 (Sch.10,40) 300 ______________________________ 2½-8 11,4 (Sch. 5, DynaFlow) Tee-Let Type C/R (Roll _Grooved _End) 11/4 6 11/4 8 (All Schedules) 300 Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe is 175 psi. AWtLStar Fire Products Division WeIdMiserTM Tee-Let® Welding Outlet Fittings Type A Female Threa WELD -MISER ITEE-LET' DIMENSIONS & PARTI1TNUMBERS Part Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each A B C D NPT(BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (kg) 1002002 1/4 x 11/4 -8 0.080 - 6 x 6 -200 004 1005012 11/4 1½ 1.063 0.700 0.500 0.171 - 32 -40 27.0 17.8 12.7 0.08 1005015 11A -2 1.063 0.700 0.500 0.171 - ½x 13x 40-50 270 17.8 12.7 0.08 1005020 2- 2½ 1.063 0.700 0.500 0.171 - 50-65 27.0 17.8 12.7 0.08 1005025 2½-8 1.063 0.700 0.500 0.169 65-200 27.0 17.8 12.7 0.08 1007012 11/4 1½ 1.125 0.900 0.500 0.260 - 32-40 28.6 22.9 12.7 0.12 1007015 1½ -2 1.125 0.900 0.500 0.260 - 3/tx 19x 40-50 28.6 22.9 12.7 0.12 1007020 2-21/2 1.125 0.900 0.500 0.260 - 50-65 28.6 22.9 12.7 0.12 1007025 2½ -8 1.125 0.900 0.500 0.256 - 65-200 28.6 22.9 12.7 0.12 1010012 11/4 - 1½ 1.250 1.145 0.500 0.331 1110012 32-40 31.8 29.1 12.7 0.15 1010015 1½ -2 1.250 1.145 0.500 0.331 1110015 40-50 31.8 29.1 12.7 0.15 1010020 2- 2½ 1.250 1.145 0.500 0.320 1110020 1 x 25 , 50-65 31.8 29.1 12.7 0.15 1010025 2½-3 1.250 1.145 0.500 0.314 1110025 65-80 31.8 29.1 12.7 0.14 1010030 3-4 1.250 1.145 0.500 0.309 1110030 80-100 31.8 29.1 12.7 0.14 1010050 5-8 1.250 1.145 0.500 0.291 1110050 125-200 31.8 29.1 12.7 0.13 1012012 11/4 -11,42 1.375 1.490 0.500 0.432 1112012 32-40 34.9 37.8 12.7 .019 1012015 1½-2 1.375 1.490 0.500 0.421 1112015 40-50 34.9 378 12.7 .019 1012020 2- 2½ 1.375 1.490 0.500 0.421 1112020 11/4 x 32x 50-65 34.9 37.8 12.7 .019 1012025 2½ -3 1.375 1.490 0.500 0.411 1112025 65-80 34.9 37.8 12.7 .019 1012030 3-4 1.375 1.490 0.500 0.389 1112030 80-100 34.9 37.8 12.7 .018 1012050 5-8 1.375 1.490 0.500 0.389 1112050 125-200 34.9 37.8 12.7 .018 1015015 1½ 1.625 1.610 0.875 0.477 1115015 40 41.3 40.9 22.2 .022 1015020 2 1.625 1.610 0.875 0.477 11/5020 1 1h 2½ 50 41.3 40.9 22.2 .022 1015025 1.625 1.610 0.875 0.477 1115025 40x 65 41.3 40.9 22.2 .022 1015030 3-4 1.625 1.610 0.875 0.477 1115030 80-100 41.3 40.9 22.2 .022 1015040 4 1.625 1.610 0.875 0.477 1115040 100 41.3 1 40.9 1 22.2 .022 1015050 5-8 1.625 1 1.610 1 0.875 1 0.477 1115050 125-200 41.3 40.9 22.2 .022 WflT II1 gjiiiir'i1PART N UMBERS Part Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each A B C 0 M NPT (BSPT) In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (kg) 1020020 2 1.750 2.067 0.875 0.857 1120020 50 44.5 52.5 22.2 0.38 1020025 2½ 1.750 2.067 0.875 0.829 1120025 65 44.5 52.5 22.2 038 1020030 3 1.750 2.067 0.875 0.829 1120030 2x 80 44.5 52.5 22.2 0.39 1020040 4 1.750 2.067 0.875 0.800 1120040 50x 100 44.5 52.5 22.2 0.36 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 22.2 1134 1020060 6 1.750 2.067 0.875 0.743 1120050 150 44.5 52.5 22.2 0.34 1020080 8 1.750 2.067 0.875 0.743 1120080 200 44.5 52.5 22.2 0.34 1025025 2½ 2.215 2.469 1.125 1.250 1125025 65 54.0 62.7 28.6 055 1025030 3 2.215 2.469 1.125 1.200 1125030 80 54.0 62.7 28.6 0.55 1025040 4 2.215 2.469 1.125 1.150 1125040 2½x 65K 100 54.0 62.7 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125050 125 54.0 62.7 28.6 0.52 1025060 6 2.215 2.469 1.125 1.150 /125060 150 54.0 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 200 54.0 62.7 28.6 0.52 1030030 3 2.500 3.068 1.500 1.750 - 80 63.5 779 1 38.1 0.19 1030040 4 2.500 3.068 1.500 1.700 - 3x 100 63.5 779 38.1 0.17 1030050 5 2.500 3.068 1.500 1.700 - 80K 125 63.5 779 38.1 037 1030060 6 2.500 3.068 1.500 1.650 - 150 63.5 77.9 38.1 1 075 1030080 8 2.500 3.068 1.500 1.650 200 63.5 779 38.1 0.75 1040040 4 3.000 4.026 2.000 3.000 - 100 76.2 102.3 50.8 1.36 1040050 5 3.000 4.026 2.000 2.900 - 4x bOx 125 76.2 102.3 50.8 1.32 1040060 6 3.000 4.026 2.000 2.800 - 150 76.2 1 , I .8 1.27 1040080 8 3.000 4.026 1 2.000 1 2.800 200 76.2 102.3 50.8 1.27 Note: Part #1002002 is not UL Listed or FM Approved. All size-on-size (i.e. 2 X 2) Tee-Lets are not FM Approved. iiKAL.Star Fire Products Division Type B Male Thread Standard Weight Type C Cut Groove Standard Weight WeIdMiserTM Tee-Let® Welding Outlet Fittings WELD-MISER Tm II1 iIIT lrsiaiiii SIZES i:i;iuw1 Male Thread Cut Groove Nominal Outlet Nominal Header Outlet Length Inside Diameter Outside Diameter Wall Thickness ej Wt Std. Wt. A B C D E F NPT(BSPT) NPT(BSPT) In. (mm) In. (mm) In. (mm) In. (mm) In. (MM) In. (mm) 1310012 2010012 11/4 11/2 3 1.049 1.315 0.133 32-40 80 26.6 33.4 3.4 1310015 2010015 11/2 -2 3 1.049 1.315 0.133 1 x 40-50 80 26.6 33.4 3.4 1310020 2010020 2- 21A 3 1.049 1.315 0.133 25x 50-65 80 26.6 33.4 3.4 1310025 2010025 21/2 -4 3 1.049 1.315 0.133 65-100 80 26.6 33.4 3.4 1310050 2010050 5-8 3 1.049 1.315 0.133 125-200 80 26.6 33.4 3.4 1312012 2012012 11,44 3 1.368 1.660 0.140 32 80 34.7 42.2 3.6 1312015 2012015 1½ 3 1.368 1.660 0.140 11/4 x 40 80 34.7 42.2 3.6 1312020 2012020 2-2½ 3 1.368 1.660 0.140 32x 50-65 80 34.7 42.2 3.6 1312025 2012025 3-4 3 1.368 1.660 0.140 80-100 80 34.7 42.2 3.6 1312050 2012050 . 5-8 3 1.368 1.660 0.140 125-200 80 34.7 42.2 3.6 1315015 2015015 1½ 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 1315020 2015020 2 3 1.610 1.900 0.145 1½x 50 80 40.9 48.3 3.7 1315025 2015025 21/t 3 1.610 1.900 0.145 40x 65 80 40.9 48.3 3.7 1315030 2015030 3-4 3 1.610 1.900 0.145 80-100 80 40.9 48.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 125-200 80 40.9 48.3 3.7 1320020 2020020 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 1320025 2020025 21/2 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 1320030 2020030 3 3 2.067 2.375 0.154 2x 80 80 52.5 60.3 3.9 1320035 2020035 4 3 2.067 2.375 0.154 50x 100 80 52.5 60.3 3.9 1320050 2020050 5 3 2.067 2.375 0.154 125 80 52.5 60.3 3.9 1320060 2020060 6 3 2.067 2.375 0.154 150 1 80 52.5 60.3 3.9 1320080 2020080 3 3 2.067 2.375 0.154 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a niven Te.e-Let is made to fit nerfer.tiv on the first listed header 5i7e If installed on the second header size marked on the fitting, a slight gap of approximately 1/2' will appear along the longitudinal centerline of the header. For example, a lx 2 - 214' Tee-Let, is a 1' outlet fitting manufactured to fit perfectly, on the 2' header size listed, while leaving a 1/32" gap along the longitudinal centerline of the 211/ size. If a perfect fit is required for a 21&' header pipe, then a 1' x 21A - 3' Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. ANA.Star Fire Products Division WeIdMiserTM Tee-Let® Welding Outlet Fittings Type B Male Thread Standard Weight Type C Cut Groove Standard Weight Type C/R Roll Groove Schedule 10 4 TII iIfl1II! ILET' - DIMENSIONSiII .j Cut Nominal Nominal Outlet Inside Diameter - D Outside Wall Thickness - F Male Thread Wt.. Groove StdStd. Wt.Sch Roll Groove Outlet 10 Header Length Diameter Standard Schedule Standard Schedule A B C Weight 10 E Weight 10 NPT (IS0-7-1) NPT (ISO-i-i) NPT(ISO-7-1) In. (MM) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) 1325025 2025025 2225025 21/t 3 2.469 2.635 2.875 0.203 0.120 2125025 65 80 62.7 67.0 762 5.0 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 2125030 80 80 62.7 67.0 76.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125035 2½x 65k 100 80 62.7 67.0 76.2 5.0 3.0 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 2125050 125 80 62.7 67.0 1 76.2 5.0 3.0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 175 80 62.7 6710 76.2 5.0 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 200 80 62.7 67.0 76.2 5.0 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 80 78.0 83.0 88.0 5.0 3.0 1330035 2030035 2230035 31A 3 3.068 3.260 3.500 0.216 0.120 85 80 78.0 83.0 88.0 5.0 3.0 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3x 80x 100 80 78.0 83.0 88.0 5.0 3.0 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 125 80 78.0 83.0 880 5.0 3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88-0 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 1 80 78.0 83.0 88.0 5.0 3.0 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 114.0 6.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4x bOX 125 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 150 1 100 102.0 108.0 114.0 1 6.0 3.0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 100 102.0 708.0 114.0 6.0 3.0 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6x 150x 150 100 155.0 161.5 168.3 71 3.0 - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 200 100 1 155.0 161.5 1 168.3 7.1 3.0 - 2080080 - 8x 1 8 4 1 7.981 8.329 8.625 0.322 0.148 200x 200 100 203.0 212.0 213.0 8.0 3.0 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a aiven Tee-Let is made to fit nerfectiv on the first listed header Si7P If installed on the second header size marked on the fitting, a slight gap of approximately 142" will appear along the longitudinal centerline of the header. For example, a 1' x 2 - 21h' Tee-Let, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1A2 gap along the longitudinal centerline of the 21," size. If a perfect fit is required for a 21/t' header pipe, then a 1 x 21h - 3" Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. -6- ANi1LStar Fire Products Division Threading Practice Weld-Miser Tm Tee-Let® N_h Hand Va,h Pjtdh Una L' Mal. Pip. T 111haperad MERIT NPT THREAD FORM 12 Fr ala Thth sj truncatiah on L3 th.ad. STANDARD NPT THREAD FORM Installation Welding Outlet Fittings NPTiir 1!1PIPE I! Drop Nipple LI LI Total 12 or Tee-Let Hand Tight Wrench Tight Li - 13 Effective Outlet Size Lenoth Threads In. (mm) In.(mn) Threads fjjj d' '1!jqjjj Threads fl) d" ½ 0.320 448 0.214 300 0.534 7.48 0.534 7.47 15 ._ -136 3/4" 0.339 0.214 300 0.553 7.75 M 20 8.6 54 14.0 j27 _ 0.400 0.261 0.661 7.60 683 7.85 25 102 6.6 1 - 16.8 - 11/4' 0.420 483 0.261 300 0.681 7.83 0.707 813 32 WI 6 -18.0 1½' 0.420 4.83 0.261 3.00 0.697 7.83 &32 40 J2L_ - -18.4 0.436 501 0.261 300 0.706 8.01 0.157 8.70 50 11.1 6.6 17.9- - 21/2' 0.682 546 0.250 2.00 0.932 7.46 1138 9.10 85 17.3 6A 23.7 28.9 3 0.766 6 0.250 2.00 1.016 8.13 1,200 9.60 80 19 6A - 25.8 -30,5 4 0.844 675 0.250 2.00 1.094 8.75 300 40 I°° _ ILL - I 33- Domestic Manufacture Increasingly, federal, state, municipal, and quasi municipal authorities require domestic content for fire sprinkler systems. Merit® Tee-Lets® meet these requirements. The need to maintain dual inventories; one domestic; one import is eliminated. Welding Practice Tee-Let® thread form is consistent with Aeronautical National Form (ANPT) AS71051. The thread is fully formed over both the L-1 hand tight and L-3 wrench tight threads. NPT tapered threads are typically gauged only over the L-1 threads. This makes Tee-Lets more forgiv- ing of field cut threaded pipe that may only marginally conform to the specification. Fewer leaks translate into lower costs. Ease of Installation Merit Manufacturing Tee-Lets are designed to sit higher on the pipe, thereby requiring less weld and eliminating burn through. Tee-Lets sit higher on the header or branch line pipe than competitive fittings. This allows the welding torch to remain in an optimum position for welding. In addition, 11,' and larger Type A female threaded and Type C grooved Tee-Lets require the same hole size for installation. This re- sults in fewer change overs when installed using automatic welders. When measured with respect to linear inches of weld required for installation, Tee-Lets require up to 15% less weld than competitive fittings. This reduces time and savings over time are substantial. The diameter of the contoured end of Type A Tee-Lets has been reduced so that the wall thickness more nearly matches the header or branch line pipe wall thickness. Therefore, current and voltage settings required for welding are set to provide for adequate penetration without burn through and cold shutting. Also, weld volume required for installation is lower for Tee-Lets than most other fittings. Typically, Tee-Lets re- quire one-weld pass for attachment. 2.650' - 2.820' .205'-4 I-.--- 2" Merit Weld-Miser Tee-Let .325"-11 - 2" Competitive Fitting WELDINGPRACTICE Outlet I MERIT WELD-MISER TEE-LET I COMPETITIVE FITTING WELD VOLUME LINEAR WELDING WELD VOLUME* LINEAR WELDING Size In. (mm) Cross Sec. Area %Iess In. (mm) %Iess Cross Sec. Area %more In. (mm) %Iess 0.051 sq. in. 2.48 0.058 sq. in. 2.48 12% 0% 12% 0% 25 32.9 sq mm 62.9 37.4 sq mm 62.9 11/4' 0.032' 2.88 0.063 3. 01 48% 4% 48% 4% 32 20.6 73.1 40.6 76.4 1½' 0.036' 3.12 0.060 3. 46 40% 10% 40% 10% 40 23.2 79.2 1 38.7 1 87.8 0.040' 3.77 0.106 4.41 62% 15% 62% 15% 50 25.8 95.7 68.3 112.0 ANJtL.Star -7- Fire Products Division RECOMMENDED TEE-LET HOLE SIZES Tee-Let Size Type Recommended Hole Size In./mm In/mm /2 Type % 13 16 34 Type 19 22 1 Type 11/8 25 28 114 Type 1h 31 38 11/4 Type 1% 31 35 11½ Type AorC 1% 38 41 2 Type AorC 2 50 50 21½ Type AorC 2A 63 61 3 Type AorC 3 75 75 4 Type AorC 4 100 100 Holes may be cut emolovina mechanical means—includino hole sawino. mechanical flame cutting (oxy-acetylene or propane), and air plasma cutting (constricted tungsten arc) machines. Merit offers a simple approach to cut- ting the hole. Hand-held templates are sized to match your plasma cutter. l/ 3/4 & 1 Outlet Weld:MiserTM Tee-Let® Installation (cant.) Welding Outlet Fittings Recommended Installation Procedures Merit Weld-Miser Tee-Let Welding Outlet Fittings are designed and manufactured to reduce the cost of installa- tion from both the standpoint of labor required and energy consumed. In addition, by following the recommended in- stallation procedures, many of the problems associated with installing welding outlet fittings on standard weight or light weight pipe are eliminated, including burn through and excessive shrinkage resulting in pipe distortion. Recommended Hole Sizes The hole cut in the branch or header pipe can be cut prior or sub- sequent to attachment of the Tee-Let. One advantage of cutting the hole after welding is that the pipe is left intact during welding thereby reducing shrinkage and possible distortion. If holes are cut prior to welding, as some codes require, then the following hole sizes are recommended. Note that the same hole diameter for a given outlet size is required for both Type A and Type C Tee-Lets 1-1 /2 larger. Recommended Welding Procedures Merit Weld-Wiser Tee-Lets are designed to be installed on standard weight or light weight pipe with one weld pass on Type A outlet sizes from 1/20 through 21/2 inclu- sive, and on Type C outlet sizes through 4u Moreover, the wall thickness at the weld end of the fitting approximately matches standard weight pipe. Accordingly, heat setting can be made to optimize penetration on both the fitting and the pipe which it is being welded. Aside from reducing the likelihood of burn through and distortion resulting from excessive heat, the amount of weld required for adequate penetration is significantly reduced. Merit Tee-Lets are manufactured from continuous cast aluminum killed steel with a carbon range of from 0.05 to 0.25. Merit specifies that residuals, such as chrome, nickel and other metals resident in the scrap used for production of the steel be reported and kept to a minimum. On the other hand, certain grades of carbon steel pipe are manufactured from skelp whose chemical composition is not speci- fied. When the metal inert gas shield (MIG) welding process is employed, certain residuals may cause excessive porosity, spatter or lack of penetration. Specifically, gases released during the welding process do not escape before the molten puddle sets up. Wheh porosity or lack of penetration occurs, one approach is to slightly increase the heat in order to give the gases time to escape from the puddle. A flux cored wire can also be used. This wire contains scavengers which allow gases in the molten weld puddle to escape before the weld solidifies.The following recom- mended settings for welding therefore may need to be adjusted slightly higher if any of the above mentioned adverse conditions exist. As a general rule, the weld should be only as hot as required to allow the weld to penetrate the materials being welded while concomitantly allowing gases developed in the welding process to escape. Every effort must be made to avoid welding too hot or overheating both the pipe and the Tee-Let. Excessive heat may cause the wrench tight threads (those in the bottom of the Tee-Let near the weld zone) to distort while also causing the branch pipe to bend. It should be noted that Merit Tee-Lets have been subjected to exhaustive testing and evaluation, and only negli- gibly distort when subjected to excessive heat. The threads, on the other hand, may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide, and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. —8- RECOMMENDED AMOUNT :iiaviu' Outlet A B Size In/mm In./mm In/mm 1/2 '/4 /l6 13 7 5 1/ 19 7 5 1 1/4 /16 25 7 5 1'/4 V4 A6 31 7 5 1/4 38 8 7 2 A6 1/4 50 8 7 21½ 1/4 63 8 7 3 75 10 5 4 % 100 10 5 AiIi...Star Fire Products Division WeldMiserTM Tee-Let® Installation (cont.) Welding Outlet Fittings RECOMMENDEDT WELDING PROCESS, CONTINUED i,iiui NEXT .soi Header Size Pipe Wall Thickness Tee-Let Types A, B, C Electrode Size Welding Current Arc. Volts Wire Feed Travel Speed In/mm In/mm In 1mm AMPS-DC PUS. IPA! IPM ½-2 0.035 100-130 16-20 210 25-30 0.065 13-50 2½-4 0.035 115-150 17-21 270 20-25 2 114-2 63-100 14-2 0.035 110-140 18-22 220 25-30 31-50 0.109 13-50 214-4 0.035 120-160 19-22 290 20-25 3 63-100 14-2 0.035 110-140 17-20 210 20-25 0.083 13-50 214-4 0.035 120-150 17-20 270 20-25 2.5 214-4 63-100 14-2 0.035 120-160 19-22 290 20-25 63-100 0.120 13-50 214-4 0.035 130-160 19-22 240 20-25 3 63-100 14-2 0.035 120-150 17-20 210 20-25 0.109 13-50 21/2 -4 0.035 130-150 18-20 270 15-20 3 63-100 5-6 14-2 0.035 130-160 19-22 290 20-25 125-150 13-50 214-4 0.035 140-160 20-22 270 15-20 0.134 3.5 63-100 214-4 0.045 180-205 20-24 245 27-32 63-100 14-2 0.035 120-150 17-20 240 20-25 13-50 2h/24 0.035 130-150 18-20 260 15-20 0.109 3 63-100 214-4 0.045 170-220 18-22 290 12-18 8 63-100 14-2 0.035 130-160 19-22 240 20-25 200 13-50 0.148 214-4 0.035 140-160 20-22 260 15-20 3.5 63-100 214-4 0.045 180-225 20-24 290 12-18 63-100 Shielding Gas Flow (FOR ALL sizEs) 20-25 CFH Co2 - Deeper penetration, faster welding, low cost. 25% - Argon, 75% - CO2, Recommended for .134 wall and lighter, high welding speeds without melt through, minimum distortion and spatter, good penetration. Merit assumes no liability for any consequential damages resulting from the improper use of its Tee-Let Welding Outlet Fittings, not for any recommendations made with respect to installation procedures. iiMLStar —9— Fire Products Division wJ ANVI Li INTERNATIONAL, INC. Corporate Offices 110 Corporate Drive, Suite 10 • P.O. Box 3180 Portsmouth, NH 03802-3180 Tel: 603-422-8000 • Fax: 603-422-8033 E-mail address - Webmaster@anvilintl.com www.nvilintl.com For Sales and Service Information Contact the Regional Service Center Nearest You or Visit Our Website at www.anvilstar.com U.S. Regional Service Centers NORTHEAST REGION Servicing: Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, East Pennsylvania, Rhode Island, Vermont, Virginia 2530 Pearl Buck Road Bristol, PA 19007 Tel: 215-788-4056 • Fax: 215-788-4475 Toll Free: 1-800-451-2935 MIDWEST REGION Servicing: Illinois, Indiana, Iowa, Kansas, Kentucky, Michigan, Minnesota, Missouri, Nebraska, North and South Dakota, Ohio, West Pennsylvania, West Virginia, Wisconsin 750 Central Avenue University Park, IL 60466 Tel: 708-534-1414 • Fax: 708-534-5441 Toll Free: 1-800-301-2701 SOUTHERN REGION Servicing: Alabama, Arkansas, Colorado, Florida, Georgia, Louisiana, Mississippi, New Mexico, North and South Carolina, Oklahoma, Tennessee, Texas, Wyoming 1313 Avenue R Grand Prairie, TX 75050 Tel: 972-343-9206 • Fax: 972-641-8946 Toll Free: 1-800-451-4414 WESTERN REGION Servicing: Alaska, Arizona, California, Hawaii, Idaho, Montana, Nevada, Oregon, Utah, Washington 1385 Greg Street Sparks, NV 89431 Tel: 775-331-7029 • Fax: 775-331-5075 Toll Free: 1-800-572-0051 EUROPE & MIDDLE EAST REGION Rick van Meesen, Business Director the Netherlands Tel: +31 53 5725570 Fax: +31 53 5725579 U.S. Customer Service Tel: +1 708 534 1414 LATIN AMERICA, PUERTO RICO & MEXICO Art Gutierrez, Sales Manager Tel: 813-300-3721 U.S. Customer Service Tel: 708-534-1414 • Fax: 708-534-5441 tar TM Fire Products Division of Anvil' International ANVILSTAR CUSTOMER SERVICE CENTER Tel: 708-534-1414 • Fax: 708-534-5441 Toll Free: 1-800-301-2701 #327 / Printed in USN RPI / 2.5M / 4.05 / ©2005 Anvil International, Inc. Juctile Iron Threaded Fittinc • -. S. -C. •, .. •• '5'. • • .5 . . . - /1 - 71,17v M- -1. III SMITH COOPERS INTERNATIONAL Ductile Iron Threaded Fittings citications <: branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP cULus Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working. Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 C@U, APPROVED Fig. 35E 3_900 Elbow LISTED I Size Part Number A in Packing Weight lb Inner Master I 1/2 35E 3004 1.13 100 200 0.2 I 35E 3006 1.31 70 140 0.3 I 1 35E 3010 1.50 40 80 0.5 L 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x1/2 35RE3006004 1.20 1.22 80 160 0.3 1x1/2 35RE3010004 1.26 1.36 70 140 0.4 1x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 - 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1J2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2x1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1 13 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow I L Size _in Part Number A in Packing Weight lb Inner Master 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 _ 1/2 1 35F 3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 35F 3020 1.69 101 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T3004 1.13 80 160 0.3 3/4 35T3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmichcooper.com C@US APPROVED Fig. 35RT3 - Reducing Tee LISTED Size in Part urn er A in B in C in Packing Weight lb Inner Master 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 lx 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1x3/4 35R13010006 1.38 1.38 1.45 25 50 0.6 1 x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x 3/4 x1-i/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35R13012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x lxi 35R73012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35R13014004 1.41 1.41 1.66 16 32 tO 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-112 x 1/2 x 1 1/2 35R13014004014 1.94 1.66 194 12 24 12= 1-1/2x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35fRT3014006012 1.94 1.66 1.88 20 40 ii 1-1/2x3/4x1-1/2 35RT3014006014 1,94 1.75 1.94 18 36 1.2 i-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 :10 . 1.44 115 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 i • 1.88- 1.2 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35R13014012 :1.. 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-i/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35R13014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35R13020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35R13020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-i/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x 3/4 35R13020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-i/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35R13020014014 2.02 1 1.94 2.16 8 16 1.8 Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1 35B13006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 _0. lx 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 i-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35813014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 . 35813014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • www.smithcooper.com 112 Fig. 35CP3 - Straight Coupling with Ribs c®uS <> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 1 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Pa rt Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 I 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35SP3 - Square Head Plug Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2x 1 (not hex)l 35RC3020010 2.81 20 40 1 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35U 3- Union with Brass Seat Size in Part Number ______________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smichcooper.com I L. !H ceus APPROVED A Fig. 3513- Cross LISTED Size in Part Number ____ A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 1 2.25 1 6 12 1 2.8 Fig. 35R13 - Reducing Cross I Size ' I in I Part Number I I A I . I in I B I in acking I Weight I lb I Master 1-1/4x1 35RX3012010 1.67 I 1.58 FInner 30 1.2 1-1/2x1 I 35RX3014010 1.80 1.65 24 1.4 2x1 35RX3020010 2.02 1.73 16 2.0 Fig. 35C 3- Cap LJI Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 1 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C3024 1.70 18 36 1.6 Fig. 358C3 - Beam Clamp Size in Part N umber u A in Packing J Weight 1 lb Inner Master 3/8 35BC3003 0.75 100 1200 1 03 1/2 35BC3004 0.75 80 1 160 1 0,5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 wwwsmithcooper.com 114 For reference only-Existing ES-7O9DCDA Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series 709DCDA Double Check Detector Assemblies Sizes: 3" -10" (80-250mm) Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authori- ty containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable qual- ity from being pumped or siphoned into the potable water line. Benefits: Detects leaks. . . with emphasis on the cost of unac- countable water; incorporates a meter which allows the water utility to: detect leaks underground that historically create great annual cost due to waste. provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves, %" x 3/4' (16 x 19mm) meter and ball type test cocks. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with /8" x 3/4' (16 x 19mm) bronze meter No special tools required for servicing Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water sup- ply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be UL/FM approved with UL/FM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; AWWA Std. C510 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709DCDA. 7O9DCDAOSY Check / Mo Test Cock Cover Seat Disc Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not inter- changeable. T Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INS TALLAI1ON REQUIREMENTS Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- IWWATM out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Body: Epoxy coated cast iron Seat: Bronze Disc Holder: Bronze Trim: Stainless steel Check Valve Discs: Rubber Test Cocks: Bronze Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter LF - 4" - 10" (100 - 250mm) without shutoff valves Dimensions - Weights Pressure - Temperature Temperature Range: 33°F - 110°F (0.5° - 43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175psi (112.1 bar) Standards AWWA Standard C510 Approvals Approved C US 1 8 B.64 048 Approved by the foundation for Cross-Connection Controland Hydraulic Research at the University of Southern California. Sizes 4 - 10° (100 - 250mm) approved for horizontal and vertical 'flow up". Size 3" (76mm) approved for horizontal only. Factory Mutual approved 4" - 10" (100-250mm) vertical "flow up". .................A ................................................ I SIZE (DN) DIMENSIONS WEIGHT In. mm in. A mm C in. mm D in. mm in. E mm in. L mm in. R mm T in. mm in. mm U.W,OSYt gates lbs. kgs. 3 80 40 1016 181/8 479 3½ 89 12 305 24 610 14 356 3 76 14 356 190 86 4 100 52 1321 22/4 578 33/4 95 17 432 34 864 15 381 6 152 14 356 403 183 6 150 621/2 1588 1 301/a 765 1 41/2 114 21 533 411/2 1054 16 406 71/2 191 16 406 727 330 8 200 1 75 1905 1 373/4 959 51/2 140 1 26 660 1 52 1321 1 17 432 1 9 229 1 21 533 1 1327 602 10 250 1 90 2286 1 453/4 1162 61/2 165 1 32 813 1 64 1626 1 18 457 1 101/4 260 1 25 635 1 2093 949 ° Service clearance for check assembly from center. tUL/FM apprbved backflow preventers must include UL/FM approved OSY. Capacity *Typical maximum system flow rate (7.5 ft/Sec.) **UL rated flow :••••• F• --• r•••• i•...•u•..... rr••••u i••.••. ....• MMEIMMMMMEMMMM_, (ti ii .Iii 7i ii I1ti iI UIl' U lUl l• __I !' 1IIiI]ii1Th ---- riii' ------ ---- —-- IULUJ =-- ---- ii. ,------ —___ ---- ,. ------ ---- ---- ---- ---- LII I I It It •ll Il II I jl I I.1l *Il A IL.1'1T1Th _______. ____ I__ =---- i___ ___It ___ i•i ru•i . i I •• ii• ----- ._ ,____.. ----a . .• [I1,!I For additional information, visit our web site at: www.watts.com WWArrS® A Watts Water Technologies Company USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. 1-71- 51-17; www.wattscanada.ca ES-709DCDA 0638 0 2009 Watts Fig. 200F a Fig. 200 Fig. 200S Fin 9flfl - "TrimIin" Arfi"qtahle Rind Hinnr 1flnnnr R-I ina Fin R217flPJR _- ®TDLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Coope;B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c@ us USTEO Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUt.) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) - Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C 200_1/2 Pipe I2 Size (15) Rod Size 3/8"-16 iin. 31/8 A üIi1I -1-1 (79.4) in. .............1......... 2/8 B (66.7) Approx. I lbs.. 11 Wt./100 (5.0) 200-3/4 3/4 (20) 1 3/8"-16 31/8 (794) 21/2 (63.5) 11 (50) 200-1 1' (25) /8'-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200_11/4 11/4" (32) /8'-16 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200_11/2 11/2' (40) /8'-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2' (50) ¶ /8'-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200_21 /2 21/2 (65) /8'-16 5/8" (142.9) 4/8" (104.7) 27 (12.3) 200-3 3 (75) II 3/8"-16 57/8 (149.1) 4 (101.6) 29 (13.3) 200_3112 31/2' (90) /8"-16 7/8" (187.3) 5/4" (133.3) 34 (15.6) 200-4 4" (100) /8'-16 7/8' (187.3) 5' (127.0) 35 (16.0) 200-5 (125) 1/2"13 91/8" (231.8) 6/4" (158.7) 66 (30.2) 200-6 (150) 1/2"13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 112"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) 44 Fig. 200-1 to 200-2 Fig. 200-2I2 to 200-8 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pill- 00 COOPER B-Line All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 53 Seismic Bracing Products B-Line by ET.N Seismic System Attachments Fig. 25 - Surge Restrainer ®TDLCO Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe. c®us Material: - Pre-Galvanized Steel LISTED Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UI) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 'i Part iNo. . B3205-318 x 'L' Thread Size 3I811 1;.O' Threp.j' Length 21/2' ' Standnrd TL (63.5) 650IF (343'C) II}. 730 wkl'i N (3.25) Load 750-F (399oC) 572".. (2.54) B3205-1/2 x ____ 21/2' (63.5) 1350 I (6.00) 1057 N..j4.70) B3205-518 x 'L' " /81-11 21/2 (63.5) 2160 T (9.61) 1692 B3205-3/4 X 'j,' /4"-10 3' (76.2) 3230 (14.37) 2530 V. (11.25) B32051'L' /8"-9 31/2' (88.9) 1 4480 1 (19.93) 3508 (15.60) er sizes consult full line pipe hanger catalog. N IDTC3LCCY T TL Specify Len TL Thread Size B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) >832O5L - Threaded Rod (right & left hand threads) Size Rang 3/'-16 thru 3-4 rod Material: SteeN.... Function: Recommëhd for use as a hanger support in hanger assemblies. Rod is threaded on bothbRds with right hand threads of the length shown. Also available with left and right h threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (Q) Finish: Plain. Contact Cooper B-Line fdN finishes and materials. Order By: Figure number, rod size, length Fig. ATR - All Threaded Rod (TOLCO Fig. 99& Fig. 100) Size Range: /8-16 thru 11/2"-6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part AIR 1/4" No. X 'L' Threads 20 Recommended ' 240 Load (1.07) Ft. Approx. Wt./100 12 ' (5.44) AIR W X '1' 16 ii 730 (3.24) 29 (13.15) AIR I2" x '1' 13 1350 (6.00) 53 (24.04) AIR W X 'L' 11 2160 (9.60) 89 (40.37) AIR 3/4" x 'L' 10 3230 (14.37) 123 (55.79) AIR /8" X 'L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line C®us USTEO APPROVED 2-#14x1" Tek Type Screws Into Mm. 16 Gauge Steel Up to 4" (100mm) pipe UL Listed Fastener Table Pipe Size Wy Fastener Type Material Bolt & Hex Nut Up to 4(100mm) pipe 2" 2 #16 xZ' Drive screws Wood 2" 1 3[9" Lag bolt Wood - 4" 1 'If Lag bolt Wood 31/2" 2 1/4' x 11/2" Lag bolts Wood 4" 2 1/4' x 2" Lag bolts ** Wood 4° 2 1/4°xl"Tekscrews Metal (l5gauge) [4° 2 1/4" xl" bk screws Metal (16 gaugJ ** No pre-drilling Larger pipe sizes can be hung with reduced spacing. Part No. Pipe Size Rod A B C Approx. Wt./100 in. (mm) Size in. (mm) in. (mm) in. (mm) Lbs. (kg) 58 i/f -4" (15- 100) !8°-16 23/4' (69.8) 11/2" (38.1) 11/8" (28.6) 14 (6.3) 1 Per NFPA 1-3/a"or1/f Lag Bolts Up to 4" (100mm) pipe 2- #16 x 2" Drive Screws 'If (15mm) -4" (100mm) pipe Upper Attachments TOLCO Fig. 58 - Threaded Side Beam Bracket Size Range: /8"-16 rod, pipe sizes 1/2° (15mm) thru 4(100mm) Material: Pre-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustmem. Center mounting hole will accept /8" and 1/2" fastener bolts. Per NFPA 13: 1/2" (15mm) thru 2° (50mm) pipe requires /8" fastener, 21/2" (65mm) thru 4° (100mm) pipe requires 1/2" fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" (100mm) pipe. Finish: Pre-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2- 114!'x 2°, Lag Bolts (No Pre-Drilling Up to 4" (100mm) pipe All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 91 Eaton Ii L :T DEWALT 4 od Concrete, Wood & Hanging iffi ENGINEERED BY?OWerS I- l-• 1 - - - ,--- --- ---- I / r ' - anqermate'5+ DEWALT 11W Buildex Hangermate+ Sammys' ITf9jf9i Suspender No I 1II1irn Yes All 2-piece I iivaoI:enTiTr 12 SKUs 8 SKUs *On select sizes with coupling nut Sammys is registered trademark of Illinois Tool Works Inc. stallath Driver Reference DEWIJPTION PHangermaote+ DRIVER Steel - Vertical iii 1/4-20 1"#3 PFM2201200 II 1/4-20x1#3 PFM2201200 ON 1/4-20 xl' #3 / nut PFM2201200 I 114"-20x 1-1/2 #5 PFM2201200 1/4-20 x 1-112' #5/ nut PFM2201200 II 1/4-20 x 1-1/2" #3 PFM2201200 I 1/4-20x1-1/2" #3/nut PFM2201200 I 1/4-20 x 2" #3 PFM2201200 Hangermate+ Steel - Horizontal 100 1/4-20 x "#3 PFM2201200 ON 1/4-20 xl" #3 / nut PFM2201200 0 1/4-20 x 1-1/243 PFM2201200 1/4-20 x 1-1/2 #3/nut PFM2201200 I I 1/4-20 x 1-1/2 #5 PFM2201200 I 1/4-20 x 1-1/2 #5 /nut PFM2201200 Pivot Steel - Angled Applications 1/4-20x1"#3 PFM2201250 }; Is 12-20 x 1-3/4" #5 PFM2201250 ! !I; 1Jo• 1/4-14 x "#3 PFM2201250 Suspender Steel - Dual-Directional ON 1/4-20 xl" #3 / nut PFM2201300.4 I 1/4-20x1-1/2" #3 /nut PFM2201300i I 1/4-20x1-1/2" #5 /nut PFM2201300 Steel - Acoustical Ceiling Screw Eyelet 1/4" x3" PFM2201350 1/4 x 3-1/4 PFM2201350 A s1AriUIeEluJI;1EI DESCRIPTION SAMMYS® MODEL # HANG ROD SIZE QTY MSTR CITY Steel - Vertical PFM2231000 1/4-20 1' #3 DSTR 100 Vertical 1/4 25 PF M2231 I: 1/4-20 x 1" #3 - Vertical 3/8" 25 ON 1 1/4-20 x 1 #3 / nut DSTR 1 Vertical 3/8 25 11111 I 1/4'-20x 1-1/2 #5 DSTR 1-1/2 Vertical 3/8 25 1/4-20 xl -1/2 #5/nut DSTR 1 Vertical 3/8 25 I I 1/4-20 x 1-1/2" #3 - Vertical 3/8 25 I 1/4-20x1-1/2" #3/nut DST15 Vertical 3/8" 25 II' I 1/4-20 x 2" #3 DST 20 Vertical 3/8" 25 Hangermate+ For Steel - Horizontal r II 100 1/4-20 x 1" #3 SOW 10 Horizontal 3/8" 25 I 1/4-20 x 1" #3 / nut SDWR 1 Horizontal 3/8" 25 :p , 15 Horizontal 3/8" 25 I 1/4-20 x 1-1/2" #5 /nut SWDR 1-1/2 Horizontal 3/8 25 Hangermate+ Pivot For Steel - Angled Applications r - V ; I 1/4-20 x 1" #3 SH-DSTR 1 Variable 3/8 25 ___________ 12-20 x 1-3/4" #5 SH-TEK 50 Variable 3/8" 25 u ; I 1/4-14 xl" #3 - Variable 3/8 25 Hangermate+ Suspender For Steel - Dual-Directional - - PFM2271,I ON 1/4-20 x 1" #3 / nut - Vert. & Horz. 3/8 25 1/4-20x1-1/2" #3 nut - Vert. &Horz. 3/8" 25 -- -PFM22713ON 1/4-20 x 1-1/2 #5 nut - Vert. & Horz. 3/8' 25 Hangermatci. For Steel - Acoustical Ceiling Screw Eyelet 1/4" x 3" CWSD 1 Vert. & Horz. EIIEyelet Hole 25 Ii. IL .J 1kI' 1{s 1/4' x 3-1/4" CWSD 2 Vert. & Horz. 3/16" 25 Recommended 1300 to 2000 rpms for proper installation. The Complete Anchoring Solution - Installation Accessories and Tools DESCRIPTION HANGERMATE+ OTY MSTR OTY _______ K4IWIIIII Steel Socket (Silver) Rod Hanger 1 5 Suspender Driver Suspender 1 5 Pivot Driver Pivot 1 5 Ceiling Screw Eyelet Driver Acoustical 1 5 ______ èDiIIII•I Pole Tool Kit Rod Hanger 1 5 _______ YAK4!.aIiIMII Adapter for hanging 1/2 rod (3/8" to 1/2" Adapter) I1PI1JJIl 20 V MAX* XR Lithium Ion Brushless 3-Speed Drill / Driver Kit - IIP;f:1,Jl 20V MAX* XR 1/4" 3-Speed Impact Driver Kit * Maximum initial battery voltage (measured without a workload) is 20 volts. Nominal voltage is 18. 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 APPROVALS I1angermate.i. For Steel - Vertical F (i) < SPP..D > A ULTIMATE DESCRIPTION HANG ROD DRIVER MIN. MAX. TENSILE LOAD LOAD PIPE UL PIPE FM SIZE THICK. THICK. (MATERIAL DIRECTION SIZE THICK. SIZE THICK. THICKNESS) 1/4-20 1" #3 Veil. 1/4 PFM2201200 0.060 0.250 2,375 (0.125) V 4" 0.125 4" 12 ga. 1/4-20x1"#3 Veil. 3/8" PFM2201200 0.060 0.250 2,375(0.125") V 4" 0.060 4' 16 ga. 1/4-20 xl" #3/nut Veil. 3/8' PFM2201200 0.060 0.250 4,690 (0.125") V 4' 0.125 4" 12 ga. 1/4-20 x 1-1/2 #5 Veil. 3/8' PFM2201200 0.188 0.250 3,675(0.188') V 4" 0.060 4' 16 ga. 1/4-20 x -1/2" #5/nut Veil. 3/8 PFM2201200 0.060 0.250 5,810 (0.188) V 4" 0.125' 4" 12 ga. 1/4-20x1-1/2"#3 Veil. 3/8 PFM2201200 0.188 0.250 2,375(0.125') V 4" 0.060" 4" 16 ga. 1/4-20 x 1-1/2' #3/nut Veil. 3/8 PFM2201200 0.060 0.250 4,690 (0.125') V - - 4" 0.125 1/4-20 x 2" #3 Veil. 3/8" PFM2201200 0.060 0.250 2,375 (0.125") V For Steel- 'Horizontal 1/4-20 x 1" #3 Horiz. 3/8' 'PFM2201200 0M60 0.250 2,570 (0.111") H - - - - 1/4-20 x 1" # /nut Hoiiz. 3/8'HPFM2201200 '0060 0.250 2,810 (0.111 ") 'H 4' 0.060" 4" 16 ga. 1/4-20x 1-1/2 #3 Horiz. 3/8' PFM2201200 0.060 0.250 2,570 (0.111') H - - - - 1/4-20 x 1-1/2" #3/nut Horiz. 3/8' PFM2201200 0.060 0.250 2,810(0.111") 'H 4" 0060" 4" 16 ga. 114-20 x 1-1/2' #5 Horiz. 3/8" :PFM2201200 10.060 0.500 3,530 (0.188') H - - - - 1/4-20 x 1-112' #5/nut Horiz. 3/8" iPFM2201200 0.060 0.500 2,810 (0.111') H 4' 0060" 4" 16 ga. Pivot For Steel- Anqled Annlicätlons 3,210 (0.188') - - - - 1/4-20 x 1' #3 Variable 3/8' PFM2201250 01060 0.188 V 45 - - - - 975 (0.188") 3,270 (0.188") V - - - - 12-20 x 1-3/4' #5 Variable 3/8" PFM2201250 10.11 0.188 975 (0.188") 45 - - - - 1/444 xl' #3 Vanable 3/8' PFM2201250 10.188 05 2,875 (0.188") V - - - - 45- 875(0.188") spender For Steel - DualDirectional 1/4-20x 1" #3/nut Vert.2 HorZ. PFM2201300 0.060 0.210 4,690 (0.125") V 4 0.060' 4" 16 ga. H 4" 0.060' 4" 16 ga. 1/4-20x 1-1/2" #3/nut Vert.& 3/8" Horz. PFM2201300 0.060 0.210 4,690 (0.125") V 4" 0.060" 4 l6 ga H 4" 0.060" 4" l6 ga 1/4-20x1-l/2"# nut Vert.2 orz. 3/8" PFM2201300 0.188 0.500 4,690(0.125') V 4" 0.060" 4" 16 ga. H 4" 0.060" 4" 16 ga. For Steel - Acoustical Ceiling Screw Eyelet 1/4" x 3" 3/16" PFM2201350 - 0.060 590 (0.188") - - - - - I 1/4" x 3-1/4 3/16" PFM2201350 - 0.060 590 (0.188") - - - - - Loads vary depending on steel thickness. Contact DEWItT for more information. Set Bolt Included Mounting Hardware Is Not Included Fig. 980 Seismic Braci TOLCO Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" (FM Approved) OPM Size Range: One size fits bracing pipe 1(25mm) thru 2' (50mm), B-Line series APPROVED 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting Features: This products design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2016) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO 'braced pipe" attachment, Fig. 1000, 1001, 3000, 4L, 4LA, or other TOLCO approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be forowed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-1 3. For UL Listed information refer to UL Listed page 60. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L, 4LA or other TOLCO approved attachment to pipe that make up a sway brace system of bracing materials which satisfies the requirements of Factory Mutual Engineering and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Fig. 1001 Contact customer service for alternative finishes. / Order By: Figure number and finish. Fig. 980 Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, /....... Fig. 41 Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Brace Pat. #7,669,806 Designed to meet or exceed requirements of FM DS 2-8. Lateral Brace Longitudinal Brace Part Mtg. Hdw. Mounting Hole Max. Design Load** (FM) Approx. Number Size A B D 30° - 440 450 -590 50 -590 60° -14° 750 -900 50 -900 Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) IbsI(kN) IbsI(kN) lbsl(kN) IbsI(kN) lbs. (kg) I 980i8 I8" (9.5) 51/4" (133.3) 1718" (47.61 13/32" (10.3) 149 (67.6) 1 980-1/2 * 1/2-02.7) 51/4" (133.3) 1/8" (47.6) I 5/8 /8" (15.9) 51/4" (133.3) 1/8" (47.6) 980-/4 3/4" (19.0) 51/4" (133.3) 1/8" (47.6) /32" (13.5) 1320 11/16" (17.5) (5.87) 13/16" (20.5) 1970 2310 2550 I 148 (67.1) (8.76) (10.27) (11.34) 147 (66.7) I 146 (66.2) * Standard size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Important! - For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors, see page 106. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise B-Line series Fire Protection Solutions 61 Eaton OPM APPROVED Set Bolt & Hardware Included Seismic Braci TOLCO Fig. 41 - Longitudinal In-Line Sway Brace Attachment (FM Approved) Size Range: 21/2 (65mm) through 8" (200mm) IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance Approvals: Approved by Factory Mutual Engineering (FM), 21/2 (65mm) through 8' (200mm) pipe. For UL Listed information refer to UL Listed page 74. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Installation Instructions: Fig. 4L is the 'braced pipe attachment component of a longitudinal sway brace assembly. ft is intended to be combined with the "bracing pipe' and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage 'bracing pipe' into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8 Brace Fig. 980 Fig. 41 Longitudinal Brace Part No. Pipe Size in. (mm) A in. (mm) C in. (mm) D in. (mm) Bolt Size 30°-44° lbs. (kN) Max. Rec. Load (FM) 450590 600-140 lbs. (kN) lbs. (kN) 750900 lbs. (kN) Approx. Wt./100 lbs. (kg) [4 1/2 21/2" (65) 6/16" (163.5) 21/2" (63.5) 2/4" (69.8) 1/2"..13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 253 (114.7) 40 3" (80) 7' (177.8) 2/4" (69.8) 31/16' (77.8) '/2'13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 268 (121.5) [41-4 4" (100) 81/2" (215.9) 3/8" (85.7) 31/16' (93.7) 1/2 -13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 348 (157.8) ] 41-5 (125) 93/4' (247.6) 3/8" (98.4) 4/8' (111.1) '/2'13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 380 (112.3) [ 41-6 (150) 111/2" (292.1) 5" (127.0) 51/' (130.2) 1/f13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 640 (290.3) ] 41-8 8" (200) 131/4" (336.5) 55/8' (142.8) 5/8" (142.9) '/2'-13 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) 728 (330.2) FM Approved when used with 1', 11/4', 11&' or 2" Sch. 40 brace pipe. FM Approved design loads are based on ASD design method. * UL Listed not FM Approved. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. D;mensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 75 Eaton OPM <j> APPROVED Seismic Braci TOLCO Fig. 4LA - In-Line Sway Brace Attachment (FM Approved) Size Range: 1' (25mm) through 12' (300mm) IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance Approvals: Approved by Factory Mutual Engineering (FM), 1(25mm) through 12' (300mm) pipe. For UL Listed information refer to UL Listed page 76. Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Installation Instructions: Fig. 4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be 4LA-1 thru 4LA-4 combined with the 'bracing member' and TOLCO transitional attachment and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. To Install: Place the Fig. 4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member (pipe or strut) with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number, pipe size and finish. Uip 4LA-6 thru 41A-12 Part No. Pipe Size in. (mm) A in. (mm) C in. (mm) D in. (mm) Bolt Size 300 440 lbs. (kN) FM Max. Rec. Load Longitudinal & tateral** 450590 600 740 lbs. (kN) lbs. (kN) 750 900 lbs. (kN) Approx. Wt./100 lbs. (kg) I 41A-1 I" (25L .9j2'j91.2) 15/16' (33.5) 15/16' (33.5) 3/t"-16 680 (3.02) 970 (4.31) 1190_(5.29)_1320 (5.87) 119 (PL....J 4LA-11/4 11/4' (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8'-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 123 (55.8) I_4LA-11/2 11/2'(40)45/32'(105.7)11/2"(38.5)11/2'(38.5)3/8'-16680(3.02)970(4.31)1190 (5.29)1320(5.87)127(57.6)] 4LA-2 2'(50)511/32'(135.6)21/32'(51.9)21/16"(51.9)3/8 -16 680(3.02)970(4.31)1190(5.29)1320(5.87)142(64.4) r412112(65)527/32(1487)25h6 _(58 5) 25h6 (58 5) 3/8 16680 (302)970(431)1190(529) - 1320 (587) 173 (LJ 4LA-3 3' (80) 61/2' (164.9) 25/8" (66.6) 25/8' (66.6) 3/8 -16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 187 (84.8) 4LA31/2 31/2' (90) 7.407" (188.1) 2/8" (73.1) 2/8' (73.1)3/8 -16 680 (3M2) 970 (4.31)1190(5.29)1320(5.87) 198 (88).J 4LA-4 4'.(100) 7 3/32" (190.8) 31/8"(79.5)31/8" (79.5) 3/8 -16 680(3.02)970(4.31)1190(5.29)1320(5.87)209(94.8) 4LA-66'(150)105/8'7269.9)49/16'(115.9)4,/16"(115.9)1/131620(Nótè1 N5i3Nöth5521 (236.3)1 4LA-8 8" (200) 1213/16" (325.5) 59/16" (143.7) 521/32' (143.7) 1/2.13 1620 (7.20) Note 2 Note 4 Note 6 629 (285.3) [41A-10 10' (250) 161/2' (419.1) 71/4" (942) 71/4" (184.2) 1/2 .13 1620 (7.20) Note 2 Note 4 Note 6 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) '/2'-13 1620 (7.20) Note 2 Note 4 Note 6 1496 (678.6) ** Longitudinal and Lateral Loads are the same except where noted in chart Brace Note 7: Longitudinal Load 2260 lbs. (10.05kN) - Lateral Load 2300 lbs. )10.23kN) Brace Note 2. Longitudinal Load 1660 lbs. (7.38kN) - Lateral Load 2300 lbs. (10.23kN) Longitudinal Fig. 980 Note 3. Longitudinal Load 2010 lbs. (8.94kN) - Lateral Load 2820 lbs. (12.54kN) Brace Fl UA Fig. 980 Note 4: Longitudinal Load 1570 lbs. (6.98kN) - Lateral Load 2820 lbs. (12.54kN) 0 g. Note 5: Longitudinal Load 2220 lbs. (9.87kN) - Lateral Load 3140 lbs. (13.96kN) V / ( ' Fig. 4LA Note 6: Longitudinal Load 1740 lbs. (7.74kN) - Lateral Load 3140 lbs. (13.96kN) ,.' Lateral - Brace Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise B-Line series Fire Protection Solutions Eaton <1> APPROVED Included Seismic Bracin TOLCO Fig. 1000 - "Fast Clamp" Sway Brace Attachment (FM Approved) Size Range: Pipe size to be braced: 1' (25mm) thru 4' (100mm) 40 1 PS. Pipe size used for bracing: 1' (25mm) and 11/4' (32mm) Schedule 40 IPS. For pipe sizes larger than 4" (100mm) please refer to TOLCO Fig. 1001. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Features: Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation: Fig. 1000 is the braced pipe' attachment component of a lateral sway brace assembly. It is intended to be combined with the 'bracing pipe' and TOLCO structural attachment component, Fig. 980 or other approved TOLCO seismic brace to form a complete bracing assembly. Follow NFPA 13 guidelines. To Install: Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals: Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For UL Listed information refer to UL Listed page 68. Application Note: Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1' pipe extension beyond the Fig. 1000 is recommended. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1' (25mm) or 11/4' (32mm)) , and finish. Designed to meet or exceed requirements of FM DS 2-8. Pipe Part Number & Approx. Wt./100 Design Load - Allowable Horizontal Capacity (lbf) Per Installation 1,Z3 Size 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe 300-440 450..590 600 740 750.900 in. (mm) I Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 1" (25) 1000-1 X 71.6 (32.5) 1000-1 X 11/4 75.8 (34.4) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) 11/4" (32) 1000-11/4 X 74.8 (33.9) 1000-11/4 X 11/4 79.1 (35.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) [11/2" (40) 1000-11/2 X 77.8 (35.3) 1000-1'/2X1'/4 82.1 (37.2) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) ] 200 (50) 1000-2 X 84.1 (38.1) 1000-2 X 11/4 88.4 (40.1) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) [1/2" (65) 1000_21/2 X j 90.2 (40.9) 1000-2'/2X1'/4 94.6 (42.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.691 (80) 1000-3 X 97.3 (44.1) 1000-3 X 11/4 101.7 (46.1) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00) FI/2" (90) 1000-31/2 X1 104.0 (47.2) 1000-3'/2X1'/4 108.4 (49.2) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2i)J (100) 1000-4 X 110.3 (50.0) 1000-4 X 11/4 114.6 (52.0) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00) 1 FM Approved when used with 1, 11/4, 11/2, or 2 inch NPS Schedule 40 GB/T 3091, EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/I 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and H, or AS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 69 Eaton OPM APPROVED Seismic Braci TOLCO Fig. 1001 - Sway Brace Attachment (FM Approved) Size Range: Pipe size to be braced: 1 (25mm) thru 8(200mm) (PS. Pipe size used for bracing: 1' (25mm) and 11/4' (32mm) Schedule 40 (PS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedule 7 through schedule 40 (PS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1' (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-1.3. For UL Listed information refer to UL Listed page 66. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1' (25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. Pipe Size in. (mm) Part Number & Approx. Wt.I100 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe Lbs. (kg) Lbs. (kg) Design Load - For Sch. 1, Sch. 10, & Sch. 40 Pipe Allowable Horizontal Capacity (lbt) Per Installation U3 30°-44° 45°-59° 60014D 15°-90° Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) (25) 1001-1 X 100.0 1001-1 X1'/4 118.0 (535) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 1 11/4"(32) 1001-11/4 X 100.0 (45.3) 1001-1'/4 X 11I4 114.0 (51.7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 11/2"(40) 1001-11/2X1 100.0 (45.3) iODi-i'/2X1'14 115.0 (52.1) 30 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58)1 (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9)30 (5.47) f 1740 (7.74) 2140 (9.52) 2380 (10.58) '(65) 1001-2'/2X1 138.6 (62.8) 1001-2'/2X1'/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (J (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X jLl60.9 (73.0) _X1 1001-4 i/_4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29)J 6" (150) 1001-6X1 190.0 (86.2) 1001-6X11I4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 8" (200) 1001-8X1 217.4 (98.6) 1001-8X11I4 238.8 (108.3) , 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/I 3091,EN 10255K, or AS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as Schedule 3". These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. Note: Metric sizes are available, contact factory. VR9~1001 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 67 Eaton CFIDDY fl Li I I I : IL iJ INO AtT 3 (Ord 10111 mv: - - 1 EMCD www.erico.com H TBranch Line Restraint System L ( Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and —v surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY' line of hanging and bracing solutions for the fire nrntnrtinn rn, rL'nt Irma fnr ractr a i ni nr, 1 " 1) C rnrn\ ii The system meets the requirements of NFPK 13, making it ideal for new construction applications. The total system is cULus Listed and FM' Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). 1JIJLLL¼IJI l%.JL(J$ '¼J I ,&J through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 800',) compared to other methods. Unlike most solutions that only accept 3/8" (Mb) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3.8" or 1/2' (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2' (M12) threaded rod. Features Accepts 3/8" or 1/2" (M 10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can beinstalled with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection JL RS 00 Li Specifications Material: Steel Finish: Electro-galvanized c®uS Part Number Pipe Size Outer Diameter Rod Size Height Length vivm1IIIIIIIIII csaBRp0100EG 1.32" 3/8", 1/2" 6.67" 1.63" 0.88" CSBBRPO125EG" 1 1/4" 1.66" 3/8" "1/2 T 7561 1 97 088 CSBBRP0150EG 1 1/2" 1.90" 3/8", 1/2" 8.20" 2.21" 0.88" CSBBRP6200EG'c ' 2.38" M 94 www.erico.com Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to steel members with self-drilling/tapping screw Specifications Material: Steel Finish: Electro-ga Ivan ized lk c®us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 95 ERIED' DIMENSIONAL LEGEND A Adjustment BS Bolt Size CL Center Line H Height HS Hole Size ID Inside Diameter I Length MRI Minimum Rod Insertion OD Outside Diameter PS Pipe Size R Radius RS Rod Size I Thickness W Width MATERIAL USED CAST IRON: Grey Cast Iron, ANSI/ASTM® A 48-76, Class #20 MALLEABLE IRON: ANSIIASTM A 47-77, Grade Number 32510 SPRING STEEL: High Carbon Steel, tempered. STAINLESS STEEL: (54) ANSI Type 304 Stainless Steel: (S6) ANSI Type 316, ASTM A240 STEEL: M1020 Merchant Bar Quality, ANSIIASTM A 36 Prime Quality, Low Carbon, Hot Rolled Sheet, (may be Pickled and Oiled) ANSI/ASTM A 569 Commercial Quality, Low Carbon, Cold Rolled, ANSI! ASTM A 366 INSTALLATION All pipe supports, hangers, intermediate components and structural attachments must ONLY be used to support pipe, tubing or conduit as stated herein and are NEVER to be used for any other purpose. All pipe supports and hangers are designed ONLY for STATIONARY piping unless otherwise noted. All supports, hangers, clamps and accessories shown to use two nuts on the hanger rod or a jam nut must have nuts tightened securely to assure proper performance. II rC71DDy COATINGS Zinc Electroplate, Electrogalvanized (EG) ANSI/ASTM B633 This corrosion protective coating is applied after the fabrication of steel or malleable iron parts and uses an electrolytic plating process that deposits zinc up to 0.5 mils. A second passivation coating of chromate is then applied for additional protection. Zinc electroplate products are recommended for indoor and mildly corrosive applications. Pre-galvanized Zinc (PG) ANSI/ASTM A 525 and 526 Pregalvanized zinc is produced by continuously rolling steel coils or sheets through molten zinc at the mills. The coils or sheets are slit to size and fabricated by forming, shearing or punching to produce the fi nished product. During fabrication cut edges are not generally zinc coated; however, the zinc near the uncoated metal be comes a sacrificial anode to protect the bare areas. Pregalvanized zinc products are generally recommended for indoor use on mildly corrosive environments. Hot Dip Galvanized Zinc (HDG) ASTM A123 After a product has fi nished its fabrication process, it is dipped into a bath of molten zinc. The zinc completely coats all edges and surfaces. Zinc thickness is controlled by the time the part is immersed in the molten zinc bath. Hot dip galvanized zinc products are recommended for indoor, outdoor and mildly corrosive environments. IMPORTANT: For more detailed information on a specific product, application or application environment, please contact ERICO Engineering. CADDY® ARMOUR The CADDY® ARMOUR coating system features bi-metallic corrosion protection with an inorganic basecoat for sacrificial protection and an organic topcoat for barrier protection. The ERICO standard for CADDY ARMOUR includes at least 1,000 hours resistance against red rust when tested per the ASTM Bill, DIN 50021, or ISO/R 1456 salt spray tests. The CADDY ARMOUR manufacturing line is optimized to control heat energy, thereby minimizing fossil fuel use. Our energy-efficient coating process minimizes waste by reusing coatings in the process, rather than by burning off excess coatings, into the air. The entire coating process has been designed with a waste minimization approach, which allows the reuse of water and process streams. CADDY® ARMOUR is RoHS compliant. *Note Spring steel fasteners are for indoor use in non-corrosive environments. Mild steel fasteners can be used outdoors in humid or mildly corrosive environments. Not to be used in certain areas such as over indoor pools, etc. 122 www.enco.com ERICO 0 www.erico.com AUSTRALIA CHINA HUNGARY NORWAY SWITZERLAND Phone 1.800-263-508 Phone ,86-21-3430-4878 Phone 06-800-16538 Phone 800-100.73 Phone 0800-5546-97 Fax 1-800423-091 Fax .86-21-5831-8177 Fax +39-0244-386-107 Fax 800-100-66 Fax 0800.55-96-15 BELGIUM DENMARK INDONESIA POLAND THAILAND Phone 0800-75748 Phone 80849-372 Phone .62-21-575-0941 Phone +48-71-349-04-60 Phone +66-2-267-5776 Fax 0800.757-60 Fax 80849-373 Fax +62-21-575-0942 Fax .48-71-349-04-81 Fax .66-2-636-6988 BRAZIL Phone .55-11-3623-4333 Fax ,55-11-3621.4066 H CANADA Phone .1-800-677-9089 Fax .1-800-6774131 11 FRANCE Phone 0-800-901-793 Fax 0-800-902-024 GERMANY Phone 0-800-189-0272 Fax 0-800-189-0774 H ITALY Phone 800.870-938 Fax 800-873-935 MEXICO Phone .52-55-5260-5991 Fax ,52-55-5160-3310 SINGAPORE Phone .65-6-268-3433 Fax .65-6-268-1389- I SPAIN Phone. 900-993-154 Fax 900-807-333 UNITED ARAB EMIRATES Phone +971-4481-7250 Fax +971-4-881-7270 UNITED KINGDOM Phone 0808-2344-670 Fax 0808-2344-676 CHILE HONG KONG NETHERLANDS SWEDEN UNITED STATES Phone .56-2-370-2908 Phone .852-2764-8858 Phone 0800-0200-135 Phone 020-790-908 Phone 1-800-750-9321 Fax .56-2-369-5657 Fax .852-27644486 Fax 0800-0200-136 Fax 020.798-964 Fax +1-440-248-0734 WARNING ERICO products shall be installed and Used only as indicated in ERICO'S product instruction sheets and training materials. Instruction sheets are available at swiw.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO'S instructions and warnings may cause product-malfunction, property damage serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALl. EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformilies ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return she purchase price to the Buyer. THE FOREGOING STATES BUYER'S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful Or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY WSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. ANSI is a registered trademark of American National Standards Institute. cULus is a registered certification mark of UL ILC. FM is a registered certification mark of FM Approvals L-C, LTD. HangerMate is a registered trademark of Acument Intellectual Properties, LLC. NFPA is a registered trademark of National Fire Protection Association, Inc. UL is registered certification mark of UL U.C. Copyright 02008, 2009, 2010, 2013 ERICO International Corporation. All rights reserved. CADDY, CAOWELD, CRITEC, ERICO, ERIFLEX. ERITECH, and LENTON are registered trademarks of ERICO International Corporation. M1148C.NAEN M380C1136A6N w80813 3 Head Box Heavy duty 20 gauge steel construction (6510152) 6 Head Box 6 Large Head Box (6510151A) 6510 151) — 1:icIj. FIRE SPRINKLER SPARE HEADBOXES 12 Head Box (6510150) Red powder coated finish Knockouts and shelf to accommodate any 1/2" or 3/4" sprinkler head All-welded construction and full length hinge Slotted for easy mounting with screws, rivets or strapping The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM ARGCO VINYL SPRINKLER IDENTIFICATION DECALS 'White Vinyl Crack and Peel Decals with Bright Red Ink. -Available as generic signs or personalized. 'ID signs, inspection decals, hydracalc placards and services stickers. AIR CONTROL] ~~ANTRREEZESY~M][FIRE EXTINGUISHERO INSPECTORS TEST} 50-20-010 AIR LINE ] 50-20-045 AUXILIARY DRAIN 50-20-200 [HREDEPARIMENIVALVE 50-20-270 MAIN CONTROL 50-20-020 ALARM LINE_ 50-20-070 CONTROL VALVE 50-20-201 :FIRE HOSE 50-20-280 MAIN DRAIN 50-20-030 50-20-100 50-20-205 50-20-290 ALARM TEST] DRAIN VALVE FIRE SKLER IOPEN SPRINKLER CONTROL] PIPE 50-20-040 50-20-140 50-20-221 50-20-300 FIRE PROTECTION ESPRINKLER 8"x 2" 50-20-219 50-20-317 TEST & DRAIN 50-20-355 WATER MOTOR LINE 50-20-390 SPRINKLER SPRINKLER .0 SERVICE STICKERS A Great Way to Advertise Right on the Jobsite *AR1CCAPut your Company Name & Logo on your Service Decals A ARGCO's art department can take your personalized artwork and recreate it on your signs - , SP RNP. MSRMPONIICIION 24 HR. EMERGENCY SERVICE Custom to your specs. "2t5'" 770-339.3737 59fl5 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the users responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Western Fire Protection Inc. Thermo Fisher Mezzanine 5781 Van Allen Way Carlsbad, CA 92008 New Mezzanine 20-1830-04 Hydraulic Calculations & Seismic Calculations 9-1-2020 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 HYDRAULIC CALCULATIONS 1111 Hydraulic Overview Job Number: 20-1830-04 Renort Descriotion: FM HC-2 Job Job Numb Design Enginean 20-1830-04 Mitchell Struck Job Name: THERMO FISHER MEZZANINE Phone (858) 513-4949 x1311 FAX Mdn055 I 5781 VAN ALLEN WAY Stat, CenhfioabonlUeanoe Number Mdness 2 CARLSBAD, CA 92008 Al-U CITY OF CARLSBAD MdneSs 3 Jab Sitetteuitding SYSTEM #3 NEW MEZZANINE System Deersity Area of Application 0.200gpm/ft2 2500.00ft2 (Actual 2591 47ftD) MoSt Demanding hprtnljerDeta lose Streams 8 K-Factor 26.00 at 10.560 250.00 c000nage Pen Sp,int,Jen Nu bar Of SprinklerS Calculated 130.00ft2 27 System Pnesare Demand System rnoceeomend 96.459 788.03 Total Demand 1038.03 @96.459 Pressure Result +17.910 (15.7%) Supplies - - Check Point Gauges Node Name Flow(pDm) Hose Flow(pm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(pm) 1 Water Supply 2700.00 250.00 117.900 97.200 BOR 83.973 86 788.03 20-1830-04_ Thermo _Fisher Water Supply at Node 1(2700.00, 250.00, 117.900, 97.200) 150- 135- - I1w 120 - Static Pressure 117.9(0—..— - - 70a0O97.200 .....105- Ill II IT I go- 1038.03 with hose streams 75- -------- _ _ 60IVrn and curve 45 30- 15- 0- 1liIIL0UliI1Jl.l.ii.l.tI'.i.I.I.I.I.I.I.t.I.I.l.LI.J.I.IIIIIIIlIIIIIIIlIlIIIIII 5500 d°65200 3300 4400 2750 3850 4950 Water flow, gpm , © M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 9/11/2020 10:00:56AM Page 1 1111 Hydrau1ic Summary Job Number: 20-1830-04 Report Description: FM HC-2 Job Job Number 20-1830-04 Design Engineer Mitchell Struck Job Name: THERMO FISHER MEZZANINE State CerSficationdi00005 Number Address I 5781 VAN ALLEN WAY Hi-S CITY OF CARLSBAD Address 2 CARLSBAD, CA 92008 Job Site/Building SYSTEM #3 NEW MEZZANINE AddresS 3 Greet/B Name 20-1830-04—Thermo—Fisher System Remote Area(s) Most Demanding Sprtflkien Data 8 K-Factor 26.00 at 10.560 000upancy FM HC-2 Job Suffix Bore Allowance Al Source 250.00 Density 0.200gpm/ft2 Ales of rippilcaden 2500.00ft2 (Actual 2591.47W) Additional Hose Supplies Node Flow(qpm) Number Of Sprinklers Calculated 27 C000nage Per Sprinkler 130.00ft2 AutoPeak Results. Pressure For Remote Glee(s) Adjacent To Most Remote Area rotA 0050 Slnearns 250.00 System Floss Demand 788.03 Total Wets, Required (Including Hose Allowance) 1038.03 Maole,um Pressure unbalance In Loops 0.000 Mae/mum VolocriyAb000 Ground 30.29 between nodes 13 and 12 Madmen, Velocity Under Ground 5.42 between nodes 3 and 4 Volume capacity of Wet Piper 2984.44ga1 Volume capacity of Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 250.00 117.900 97.200 2700.00 114.369 1038.03 96.459 17.910 Contractor Contracton Number Contact Name Contact ride Name on Contractor Phone Eaters/on Address I FAX Address 2 Dm01 Address 3 Web-She G ©M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 9/11/2020 10:00:58AM Page ~jjjjHydraulic Graph Job Number: 20-1830-04 O.S,..+ ai LJr , Water Supply at Node I 150- 135--- 120 Static Pressure 117.900- 10 --- 788.03 @ 96.459 %700.00 97.200 1038.03 with hose streams 90 - 75 60 System demand curve 30- 15- 0— UJ.LIIJL1.I.I1..I..II IHIIIIII 111111111 IllillIll 1111111 11111 I I liii I I I I I I I I I 2750 5500 %50 1100 1650 2200 3300 3850 4400 gso Water flow, gpm Hydraulic Graph Water Supply at Node 1 Sldtic: P-- 117.900 Raslduat Pressure 97.200 @ 2700.00 Available Pressure at urns atTest 114.369 @ 1038.03 System award 96.459 @ 788.03 System Demand IIraaaag sasedaee.snaa at aautsal 96.459 @ 1038.03 ©M.E.P.CAD, Inc. M1 AutoSPRlNK 2018 04.4.5.0 9/11/2020 10:01:00AM Page 3 IHydrau1ic Graph Job Number: 20-1830-04 Rnsrt fl,rintirsn 1M WC'.. BOR 150- 135--- 120 Static Pressure 117.900 105- 2700.00 97.200 788.03 @ 83.973 1038.03 with hose streams 75 60= - yst'm demand cue_ 30— 1SH 01 '11fflL'J.LW.Uhhhhhh1 11111111 11111111! 111111111 111111111 lull liii III 11111 50 1100 1650 2200 2750 3300 3850 4400 4950 5500 Water flow, gpm Hydrauty G,aph BOR Stadu Pressure N/A Residual, Pressure N/A Available Pressure at lirria atTest N/A Sd.'.., Derrard 83.973 @ 788.03 Ses's" Eteererd (lvdualrg rtesadJty.arca at Souyea) 83.973 @ N/A ,,©M.E.P.CAD, Inc. 111 AutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:00AM Page 4 111 1Summary Of Outfiowing Devices Job Number: 20-1830-04 Renort Descriotion: FM HC-2 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) I Sprinkler 101 26.00 26.00 8 10.560 Sprinkler 102 26.24 26.00 8 10.754 Sprinkler 103 27.36 26.00 8 11.692 Sprinkler 104 29.38 26.00 8 13.485 Sprinkler 105 26.21 26.00 8 10.733 Sprinkler 106 26.45 26.00 8 10.930 Sprinkler 107 27.58 26.00 8 11.883 Sprinkler 108 29.61 26.00 8 13.702 Sprinkler 109 26.68 26.00 8 11.123 Sprinkler 110 26.93 26.00 8 11.327 Sprinkler 111 28.07 26.00 8 12.312 Sprinkler 112 30.14 26.00 8 14.192 Sprinkler 113 27.50 26.00 8 11.816 Sprinkler 114 27.75 26.00 8 12.032 Sprinkler 115 28.92 26.00 8 13.073 Sprinkler 116 31.05 26.00 8 15.061 Sprinkler 117 29.04 26.00 8 13.175 Sprinkler 118 29.30 26.00 8 13.413 Sprinkler 119 30.53 26.00 8 14.564 Sprinkler 120 32.75 26.00 8 16.763 Sprinkler 121 29.41 26.00 8 13.514 Sprinkler 122 29.76 26.00 8 13.838 Sprinkler 123 30.85 26.00 8 14.874 Sprinkler 124 31.18 26.00 8 15.191 Sprinkler 125 31.46 26.00 8 15.464 Sprinkler 126 32.77 26.00 8 16.776 Sprinkler 127 35.13 26.00 8 19.283 c Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. kjl AutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:08AM Page 5 111INode Analysis Job Number: 20-1830-04 Report Description: FM HC-2 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 16 30-9 P0(12-31/.) 58.451 17 30-9 P0(12-3%) 59.277 18 30-9 P0(12-3%) 60.006 19 30-9 P0(12-31/.) 60.653 20 30-9 P0(12-3%) 61.235 21 30-9 P0(12-3%) 61.762 22 30-9 P0(12-31/2) 62.247 23 30-9 P0(12-31/2) 62.696 24 30-9 P0(12-31/.) 63.118 25 30-9 P0(12-3%) 63.518 26 30-9 P0(12-3%) 63.900 27 30-9 P0(12-3%) 64.268 28 30-9 P0(12-3%) 64.625 29 30-9 P0(12-3%) 64.971 30 30-9 P0(12-3%) 65.306 31 30-9 P0(12-31/.) 65.628 32 30-9 P0(12-3%) 65.935 33 30-9 P0(12-3%) 66.223 34 30-9 P0(12-3%) 66.489 35 30-9 P0(12-31/.) 66.729 36 30-9 P0(12-31/.) 66.940 37 30-9 67.029 38 30-9 P0(12-3%) 67.041 39 30-9 P0(12-31/.) 67.062 40 30-9 P0(12-3%) 67.078 41 30-9 P0(12-3%) 67.091 42 30-9 P0(12-3%) 67.107 43 30-9 P0(12-3%) 67.114 44 30-9 P0(12-3%) 67.118 45 30-9 P0(37-81/.) 67.122 46 30-9 P0(12-3%) 69.276 47 12-41/. P0(9-11) 18.649 48 30-9 P0(12-3%) 69.114 49 30-9 P0(12-3%) 68.967 50 30-9 P0(12-3%) 68.834 51 30-9 P0(12-3%) 68.713 52 30-9 P0(12-3%) 68.603 53 30-9 P0(12-3%) 68.504 54 30-9 P0(12-3%) 68.413 55 30-9 P0(12-31/.) 61.883 56 30-9 P0(12-3%) 61.894 57 30-9 P0(12-3%) 61.930 58 30-9 PO(12'-3',4) 61.997 59 30-9 P0(12-3%) 62.100 60 30-9 P0(12-31/2) 62.240 61 30-9 P0(12-3%) 62.415 62 30-9 P0(12-31/.) 62.622 63 30-9 P0(12-31/.) 62.860 64 30-9 P0(12-3%) 63.123 65 30-9 P0(12-3%) 63.409 66 30-9 P0(12-3%) 63.714 67 30-9 P0(12-31/.) 64.035 68 30-9 P0(12-31/i) 64.369 69 30-9 P0(12-3%) 64.714 70 30-9 P0(12-3%) 65.069 71 30-9 P0(12-31/.) 65.436 72 30-9 P0(12-31/.) 65.817 73 30-9 P0(12-3%) 66.215 74 1 30-9 1 P0(12-3%) 66.634 75 30-9 P0(12-31/2) 67.081 76 30-9 P0(12-3%) 67.561 77 30-9 130(12-3%) 68.084 , © M.E.P.CAD, Inc. JJ AutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:10AM Page 6 INode Analysis Job Number: 20-1830-04 Pnrf fl,,+i,,,,. CRA IJ('') Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 78 30-9 68.372 1 -01-0 S 96.459 788.03 101 13-01/2 Spr(-10.560) 10.560 26.00 102 13-0% Spr(-10.754) 10.754 26.24 103 13-0% Spr(-11.692) 11.692 27.36 104 13-0% Spr(-13.485) 13.485 29.38 105 13-0% Spr(-10.733) 10.733 26.21 106 13-0% Spr(-10.930) 10.930 26.45 107 13-0% Spr(-11.883) 11.883 27.58 108 13-01/2 Spr(-13.702) 13.702 29.61 109 13-0% Spr(-11.123) 11.123 26.68 110 13-0% Spr(-11.327) 11.327 26.93 111 13-01/2 Spr(-12.312) 12.312 28.07 112 13-0% Spr(-14.192) 14.192 30.14 113 13-01/2 Spr(711.816) 11.816 27.50 114 13-01/2 Spr(-12.032) 12.032 27.75 115 13-01/2 Spr(-13.073) 13.073 28.92 116 13-0% Spr(-15.061) 15.061 31.05 117 13-0% Spr(-13.175) 13.175 29.04 118 13-01/2 Spr(-13.413) 13.413 29.30 119 13-0% Spr(-14.564) 14.564 30.53 120 13-01/2 Spr(-16.763) 16.763 32.75 121 13-01/2 Spr(-13.514) 13.514 29.41 122 13-0% Spr(-13.838) 13.838 29.76 123 13-0% Spr(-14.874) 14.874 30.85 124 13-0% Spr(-15.191) 15.191 31.18 125 13-01/2 Spr(-15.464) 15.464 31.46 126 13-0% Spr(-16.776) 16.776 32.77 127 13-0% Spr(-19.283) 19.283 35.13 2 4-0 LtE(22'-01/2) 98.025 3 -4-0 LtE(16'-7) 90.004 4 4-0 T(59'-41/2) 87.908 5 1-0 E(17'-7) 85.273 6 1,-0 fE(12'-7), BOR 83.973 7 12-41/2 P0(9-li) 18.737 8 12-41/2 P0(9-li) 19.029 9 12-41/2 P0(9-11) 19.687 10 1241/2 P0(9-11) 20.853 11 12-41/2 P0(9-11) 23.134 12 12-41/2 P0(9-I1) 26.505 13 1241/2 49.720 14 30-9 P0(12-31/2) 56.413 15 30-9 P0(12-31/2) 57.504 ,©M.E.P.CAD, Inc. jffiAutoSPRINK2018v14.4.5.0 9/11/2020 10:01:10AM Page 7 1111 Hydrau1ic Analysis Job Number: 20-1830-04 Report Description: FM HC-2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary =. ..... Route l ..... BL 1.6820 26.00 3.75 120 0.021207 9-2 Pt 0.194 101 102 13'-O'/z 13-0% 26.00 8 10.560 10.754 Sprinkler 9-2 Pe Pv BL 1.6820 52.23 7.54 120 0.077102 12-2 Pt 0.938 102 103 13-0% 13-0% 26.24 8 10.754 11.692 Sprinkler 12-2 Pe Pv BL 1.6820 79.59 11.49 120 0.168052 10-8 Pt 1.793 103 104 13-0% 13-0% 27.36 8 11.692 13.485 Sprinkler 10-8 Pe Pv BL 1.6820 108.97 15.73 120 0.300512 1-8 Pt 4.963 104 7 13-0% 12-41/2 29.38 8 13.485 18.737 Sprinkler, E(4-111/2), P0(9-11) 14-10 16-6 Pe Pv 0.289 CM 3.2600 198.99 7.65 120 0.036485 8-0 Pt 0.292 7 8 12-4% 12-4% 90.02 18.737 19.029 Flow (q) from Route 6 8-0 Pe Pv CM 3.2600 308.84 11.87 120 0.082277 8-0 Pt 0.658 8 9 12-41/2 12-41/2 109.85 19.029 19.687 Flow (q) from Route 2 8-0 Pe Pv CM 3.2600 420.65 16.17 120 0.145726 8-0 Pf 1.166 9 10 12-41/. 12-41/2 111.82 19.687 20.853 Flow (q) from Route 3 8-0 Pe Pv CM 3.2600 535.87 20.60 120 0.228058 10-0 Pt 2.281 10 11 12-4% 12-4% 115.22 20.853 23.134 Flow (q) from Route 4 10-0 Pe Pv CM 3.2600 657.49 25.27 120 0.332952 10-1% Pt 3.371 11 12 12-41/2 12-41/2 121.62 23.134 26.505 Flow (q) from Route 5 10-1% Re Pv CM 3.2600 788.03 30.29 120 0.465466 49-101/2 Pf 23.215 12 13 12-41/2 12-4% 130.54 26.505 49.720 Flow (q) from Route 7 49-10% Pe Pv CM 4.2600 788.03 17.74 120 0.126483 67-111/2 Pt 14.659 13 14 12-4% 30-9 49.720 56.413 fT(21-6), 3fE(8'-111/2) 47-11 115-11 Pe Pv -7.966 CM 4.2600 727.47 16.38 120 0.109091 10-0 Pt 1.091 14 15 30-9 30-9 56.413 57.504 10-0 Pe Pv CM 4.2600 673.70 15.16 120 0.094644 10,-0 Pf 0.946 15 16 30-9 30-9 57.504 58.451 10-0 Pe Pv CM 4.2600 626.28 14.10 120 0.082690 10,-0 Pt 0.827 16 17 30-9 30-9 58.451 59.277 10-0 Pe Pv CM 4.2600 584.77 13.16 120 0.072837 10-0 Pf 0.728 17 18 30-9 30-9 59.277 60.006 10-0 Pe Pv CM 4.2600 548.73 12.35 120 0.064750 10,-0 Pf 0.648 18 19 30-9 30-9 60.006 60.653 10-0 Pe Pv CM 4.2600 517.71 11.65 120 0.058142 10,-0 Pt 0.581 19 20 30-9 30-9 60.653 61.235 10-0 Pe Pv CM 4.2600 491.28 11.06 120 0.052770 10,-0 Pt 0.528 20 21 30-9 30-9 61.235 61.762 10-0 Pe Pv CM 4.2600 469.01 10.56 120 0.048429 10,-0 Pt 0.484 21 22 30-9 30-9 61.762 62.247 10,-0 Pe Pv CM 4.2600 450.46 10.14 120 0.044945 10,-0 Pf 0.449 22 23 30-9 , 30-9 62.247 62.696 10-0 Pe Pv CM 4.2600 435.20 . 9.80 120 0.042169 10,-0 Pt 0.422 23 24 30-9 30-9 62.696 63.118 10-0 Pe Pv CM 4.2600 422.78 9.52 120 0.039971 10,-0 Pt 0.400 24 25 30-9 30'-9 63.118 63.518 10-0 Pe Pv , © M.E.P.CAD, Inc. 1jjjAutoSPRlNK 2018 04.4.5.0 9/11/2020 10:01:12AM Page 8 1111 Hydrau1ic Analysis Job Number: 20-1830-04 P,rnrt r.,-rinti,n• PH I-Ir'!.. Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary CM 4.2600 412.75 9.29 120 0.038234 10,-0 Pt 0.382 25 26 30-9 30-9 63.518 63.900 10,-0 Pe Pv CM 4.2600 404.56 9.11 120 0.036843 10.-0 Pf 0.368 26 27 30-9 30-9 63.900 64.268 10-0 Pe Pv CM 4.2600 397.60 8.95 120 0.035678 10-0 Pt 0.357 27 28 30-9 30-9 64.268 64.625 10,-0 Pe Pv CM 4.2600 391.08 8.80 120 0.034604 10-0 Pr 0.346 28 29 30-9 30-9 64.625 64.971 10-0 Pe Pv CM 4.2600 384.20 8.65 120 0.033485 10-0 Pt 0.335 29 30 30-9 30-9 64.971 65.306 10-0 Pe Pv CM 4.2600 376.16 8.47 120 0.032201 10-0 Pf 0.322 30 31 30-9 30-9 65.306 65.628 10,-0 Pe Pv CM 4.2600 366.33 8.25 120 0.030662 10,-0 Pf 0.307 31 32 30-9 30-9 65.628 65.935 10,-0 Pe Pv CM 4.2600 354.18 7.97 120 0.028806 10-0 Pt 0.288 32 33 30-9 30-9 65.935 66.223 10,-0 Pe Pv CM 4.2600 339.22 7.64 120 0.026596 10,-0 Pt 0.266 33 34 30-9 30-9 66.223 66.489 10,-0 Pe Pv CM 4.2600 321.01 7.23 120 0.024016 10,-0 Pt 0.240 34 35 30-9 30-9 66.489 66.729 10,-0 Pe Pv CM 4.2600 299.13 6.73 120 0.021074 10,-0 Pf 0.211 35 36 30-9 30-9 66.729 66.940 10,-0 Pc Pv CM 4.2600 273.12 6.15 120 0.017811 5,-0 Pt 0.089 36 37 30-9 30-9 66.940 67.029 6-0 Pc Pv CM 6.3570 273.12 2.76 120 0.002536 5-0 Pt 0.013 37 38 30-9 30-9 67.029 67.041 s-a Pc Pv CM 6.3570 244.45 2.47 120 0.002065 10,-0 Pt 0.021 38 39 30-9 30'-9 67.041 67.062 10,-0 Pc Pv CM 6.3570 215.00 2.17 120 0.001629 10,-0 Pt 0.016 39 40 30-9 30-9 67.062 67.078 101-0 Pc Pv CM 6.3570 184.64 1.87 120 0.001229 10,-0 Pt 0.012 40 41 30-9 30-9 67.078 67.091 10,-0 Pc Pv CM 6.3570 152.64 1.54 120 0.000864 12-6 Pt 0.016 41 42 30-9 30-9 67.091 67.107 fEE(6'-3'/2) 6-3% 18'-9'/2 Pc Pv CM 6.3570 118.87 1.20 120 0.000544 13-51/2 Pt 0.007 42 43 30-9 30-9 67.107 67.114 13-5% Pc Pv CM 6.3570 82.74 0.84 120 0.000278 13-51/2 Pt 0.004 43 44 30-9 30-9 67.114 67.118 13-5% Pc Pv CM 6.3570 43.92 0.44 120 0.000086 13-51/2 Pt 0.004 44 45 30-9 30-9 67.118 67.122 P0(37-8%) 37-8% 51-2 Pc Pv DY 2.1570 43.92 3.86 120 0.016662 102-2 Pt 2.154 45 46 30-9 30-9 67.122 69.276 fE(4'-31/2), fT(10'-S%), P0(12-3 27-1 129-3 Pc Pv CM 6.3570 788.03 7.97 120 0.018006 49-71/2 Pt 1.799 46 6 30-9 1-0 744.11 69.276 83.973 Flow (q) from Route 8 4fE(12'-7), BOR 50-31/2 99-111/2 Pc Pv 12.897 ,©M.E.P.CAD, Inc. AutoSPRlNK 2018 04.4.5.0 9/11/2020 10:01:12AM Page 9 Hydraulic Analysis Job Number: 20-1830-04 Reoort DescriDtion: FM HC-2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary CM 6.3570 788.03 7.97 120 0.018006 29'-5'/2 Pt 1.301 6 5 1-0 1-0 83.973 85.273 2fE(12-7), E(17'-7) 42-9 7221/z Pe Pv UG 8.3900 788.03 4.57 140 0.003505 45-0 Pt 0.467 5 4 1-0 4-0 85.273 87.908 LtE(22'-01/.), PlV(6-9'/2), T(59'-4 88-2% 133-2% Pe Pv 2.168 UG 7.7100 788.03 5.42 150 0.004656 389-0 Pt 2.097 4 3 4-0 4-0 87.908 90.004 T(44-8), LtE(16'-7) 61-3 450-3% Pc Pv UG 8.3900 788.03 4.57 140 0.003505 10-0 Pt 8.020 3 2 4-0 4-0 90.004 98.025 3LtE(22'-01/.), BFP(-7.753) 66-2 76-2 Pc Pv UG 7.7100 788.03 5.42 150 0.004656 19-7 Pt 0.168 2 1 4-0 -0-0 98.025 96.459 LtE(16'-7), s 16-7 36-2 Pe Pv -1.734 250.00 Hose Allowance At Source 1 1038.03 =. ..... Route 2 ..... BL 1.6820 26.21 3.78 120 0.021529 9-2 Pt 0.197 105 106 13-0% 13-0% 26.21 8 10.733 10.930 Sprinkler 9-2 Pc Pv BL 1.6820 52.66 7.60 120 0.078269 12-2 Pt 0.952 106 107 13-0% 13-0% 26.45 8 10.930 11.883 Sprinkler 12-2 Pc Pv BL 1.6820 80.23 11.59 120 0.170589 10-8 Pt 1.820 107 108 13-0% 13-0% 27.58 8 11.883 13.702 Sprinkler 10-8 Pc Pv BL 1.6820 109.85 15.86 120 0.305033 1-8 Pt 5.038 108 8 13-0% 124% 29.61 8 13.702 19.029 Sprinkler, E(4'-111/2), P0(9-11) 14-10 16-6 Pc Pv 0.289 Route 3 ..... BL 1.6820 26.68 3.85 120 0.022252 9-2 Pt 0.204 109 110 13-0% 13-0% 26.68 8 11.123 11.327 Sprinkler 9'-2 Pc Pv BL 1.6820 53.61 7.74 120 0.080897 12-2 Pt 0.984 110 111 13-0% 13-0% 26.93 8 11.327 12.312 Sprinkler 12-2 Pc Pv BL 1.6820 81.68 11.79 120 0.176305 10-8 Pt 1.881 111 112 13-0% 13-0% 28.07 8 12.312 14.192 Sprinkler 10-8 Pc Pv BL 1.6820 111.82 16.14 120 0.315214 1-8 Pt 5.206 112 9 13-0% 12-41/2 30.14 8 14.192 19.687 Sprinkler, E(4'-111/2), P0(9-11) 14-10 16-6 Pc Pv 0.289 Route4 ..... BL 1.6820 27.50 3.97 120 0.023531 9'-2 Pt 0.216 113 114 13-0% 13-0% 27.50 8 11.816 12.032 Sprinkler 9-2 Pc Pv BL 1.6820 55.25 7.98 120 0.085543 12-2 Pt 1.041 114 115 13-0% 13-0% 27.75 8 12.032 13.073 Sprinkler 12-2 Pc Pv BL 1.6820 84.17 12.15 120 0.186406 10-8 Pt 1.988 115 116 13-0% 13-0% 28.92 8 13.073 15.061 Sprinkler 10-8 Pc Pv BL 1.6820 115.22 16.64 120 0.333206 1-8 Pt 5.503 116 10 13-0% 12-41/2 31.05 8 15.061 20.853 Sprinkler, E(4'-111/2), P0(9-11) 14-10 16-6 Pc Pv 0.289 Route ..... BL 1.6820 29.04 4.19 120 0.026023 9-2 Pt 0.239 117 118 13-0% 13-0% 29.04 8 13.175 13.413 Sprinkler 9-2 Pc Pv BL 1.6820 58.34 8.42 120 0.094598 12-2 Pt 1.151 118 119 13-0% 13-0% 29.30 8 13.413 14.564 Sprinkler 12-2 Pc Pv BL 1.6820 88.87 12.83 120 0.206090 10-8 Pt 2.198 119 120 13-0% 13-0% 30.53 8 14.564 16.763 Sprinkler 10-8 Pc Pv ,©M.E.P.CAD, Inc. AutoSPRlNK2018v14.4.5.0 9/1112020 10:01:12AM Page 10 111 1 HydrauIic Analysis I Job Number: 20-1830-04 Pn,rt A I-U'..) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary BL 1.6820 121.62 17.56 120 0.368256 1-8 Pt 6.082 120 11 13-0% 12..41/z 32.75 8 16.763 23.134 Sprinkler, E(4-11%), P0(9-11) 14-10 16-6 Pe Pv 0.289 Route ..... BL 1.6820 29.41 4.25 120 0.026642 12-2 Pt 0.324 121 122 13-0'/2 13..01/2 29.41 8 13.514 13.838 Sprinkler 12-2 Pe Pv BL 1.6820 59.17 8.54 120 0.097107 10-8 Pf 1.036 122 123 13-0% 13-0% 29.76 8 13.838 14.874 Sprinkler 10-8 Pe Pv BL 1.6820 90.02 13.00 120 0.211070 1-8 Pf 3.486 123 47 13-0'/2 124h/z 30.85 8 14.874 18.649 Sprinkler, E(4-111/2), P0(9-11) 14-10 16-6 Pe Pv 0.289 CM 3.2600 90.02 3.46 120 0.008411 10-6 Pf 0.088 47 7 12 -4% 12-41/2 18.649 18.737 10-6 Pe Pv Route ..... BL 1.6820 31.18 4.50 120 0.029688 9-2 Pf 0.272 124 125 13-0% 13-0% 31.18 8 15.191 15.464 Sprinkler 9-2 Pe Pv BL 1.6820 62.64 9.04 120 0.107908 12-2 Pt 1.313 125 126 13-0% 13-0% 31.46 8 15.464 16.776 Sprinkler 12-2 Pe Pv BL 1.6820 95.41 13.78 120 0.235020 10-8 Pt 2.507 126 127 13-0% 13-0% 32.77 8 16.776 19.283 Sprinkler 10-8 Pe Pv BL 1.6820 130.54 18.85 120 0.419749 1-8 Pt 6.933 127 12 13-0% 12-41/2 35.13 8 19.283 26.505 Sprinkler, E(4'-111/2), P0(9-11) 14-10 16-6 Pc Pv 0.289 Route ..... CM 6.3570 744.11 7.52 120 0.016194 10-0 Pt 0.162 48 46 30-9 30-9 705.29 + 38.82 69.114 69.276 Flow (q) from Route 9 and 42 10-0 Pc Pv .Route 9 ..... CM 6.3570 705.29 7.13 120 0.014666 10-0 Pt 0.147 49 48 30-9 30-9 669.16 + 36.14 68.967 69.114 Flow (q) from Route 10 and 43 10-0 Pc ~Pv =. ..... Route lO ..... CM 6.3570 669.16 6.76 120 0.013306 1 10-0 1 Of 0.133 50 49 30-9 30-9 635.39 + 33.77 68.834 68.967 Flow (q) from Route 11 and 44 10-0 Pc Pv .Route ll ..... CM 6.3570 635.39 6.42 120 0.012090 10-0 Pt 0.121 51 50 30-9 30-9 603.39 + 31.99 68.713 68.834 Flow (q) from Route 12 and 41 10-0 Pc Pv - Route 12 ..... CM 6.3570 603.39 6.10 120 0.010988 10-0 Pr 0.110 52 51 30-9 30-9 573.03 + 30.36 68.603 68.713 Flow (q) from Route 13 and 40 10-0 Pc Pv =. ..... Route 13 ..... CM 6.3570 573.03 5.79 120 0.009987 10-0 Pt 0.100 53 52 30-9 30-9 543.58 + 29.45 68.504 68.603 Flow (q) from Route 14 and 39 10-0 Pc Pv Route 14 ..... CM 6.3570 543.58 5.49 120 0.009058 10-0 Pf 0.091 54 53 30-9 30-9 514.91 +28.67 68.413 68.504 Flow (q) from Route 15 and 38 10-0 Pc Pv = ..... Route 15 ..... DY 2.1570 60.56 5.32 120 0.030187 135-8 Pf 5.470 14 55 30-9 30-9 56.413 61.883 P0(12-31/.) 2fT(10'-51/.), P0(12-31/2) 45-6% 181-2% Pc Pv 0.000 CM 4.2600 60.56 1.36 120 0.001098 10-0 Pt 0.011 55 56 30-9 30-9 61.883 61.894 10-0 Pc Pv CM 4.2600 114.33 2.57 120 0.003556 10-0 Pt 0.036 56 57 30-9 30-9 53.77 61.894 61.930 Flow (q) from Route 16 10-0 Pc Pv 1,© M.E.P.CAD, Inc. AutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:12AM Page 11 Iff Hydraulic Analysis Job Number: 20-1830-04 Report Description: FM HC-2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary CM 4.2600 161.75 3.64 120 0.006757 10-0 Pt 0.068 57 58 30-9 30-9 47.42 61.930 61.997 Flow (q) from Route 17 10-0 Pe Pv CM 4.2600 203.26 4.58 120 0.010311 10,-0 Pt 0.103 58 59 30-9 30-9 41.51 61.997 62.100 Flow (q) from Route 18 10-0 Pe Pv CM 4.2600 239.30 5.39 120 0.013947 10,-0 Pf 0.139 59 60 30-9 30-9 36.04 62.100 62.240 Flow (q) from Route 19 10-0 Pe Pv CM 4.2600 270.32 6.08 120 0.017474 10,-U Pt 0.175 60 61 30-9 30-9 31.02 62.240 62.415 Flow (q) from Route 20 10-0 Pe Pv CM 4.2600 296.75 6.68 120 0.020766 10-0 Pt 0.208 61 62 30-9 30-9 26.43 62.415 62.622 Flow (q) from Route 21 10-0 Pe Pv CM 4.2600 319.02 7.18 120 0.023741 10,-0 Pt 0.237 62 63 30-9 30-9 22.27 62.622 62.860 Flow (q) from Route 22 10-0 Pe Pv CM 4.2600 337.57 7.60 120 0.026358 10,-0 Pt 0.264 63 64 30-9 30-9 18.55 62.860 63.123 Flow (q) from Route 23 10,-0 Pe Pv CM 4.2600 352.83 7.94 120 0.028604 10,-0 Pt 0.286 64 65 30-9 30-9 15.26 63.123 63.409 Flow (q) from Route 24 10,-0 Pe Pv CM 4.2600 365.25 8.22 120 0.030494 10,-0 Pt 0.305 65 66 30-9 30-9 12.41 63.409 63.714 Flow (q) from Route 25 10,-0 Pe Pv CM 4.2600 375.28 8.45 120 0.032062 10,-0 Pt 0.321 66 67 30-9 30-9 10.03 63.714 64.035 Flow (q) from Route 26 10-0 Pe Pv CM 4.2600 383.47 8.63 120 0.033367 10-0 Pt 0.334 67 68 30-9 30-9 8.19 64.035 64.369 Flow (q) from Route 27 101-0 Pe Pv CM 4.2600 390.43 8.79 120 0.034498 10,-0 Pt 0.345 68 69 30-9 30-9 6.97 64.369 64.714 Flow (q) from Route 28 10,-0 Pe Pv CM 4.2600 396.95 8.94 120 0.035570 10,-0 Pt 0.356 69 70 30-9 30-9 6.51 64.714 65.069 Flow (q) from Route 29 10,-0 Pe Pv CM 4.2600 403.83 9.09 120 0.036720 10,-0 Pt 0.367 70 71 30-9 30-9 6.89 65.069 65.436 Flow (q) from Route 30 10,-0 Pe Pv CM 4.2600 411.87 9.27 120 0.038083 10,-0 Pt 0.381 71 72 30-9 30-9 8.04 65.436 65.817 Flow (q) from Route 31 10-0 Pe Pv CM 4.2600 421.70 9.49 120 0.039781 10-0 Pt 0.398 72 73 30'-9 30-9 9.83 65.817 66.215 Flow (q) from Route 32 10-0 Pe Pv CM 4.2600 433.85 9.77 120 0.041929 10-0 Pf 0.419 73 74 30-9 30-9 12.16 66.215 66.634 Flow (q) from Route 33 10-0 Pe Pv CM 4.2600 448.81 10.10 120 0.044642 10,-0 Pt 0.446 74 75 30-9 30-9 14.96 66.634 67.081 Flow (q) from Route 34 10,-0 Pe Pv CM 4.2600 467.02 10.51 120 0.048050 10,-0 Pt 0.480 75 76 30-9 30-9 18.21 67.081 67.561 Flow (q) from Route 35 10-0 Pe Pv CM 4.2600 488.90 11.01 120 0.052299 10,-0 Pt 0.523 76 77 30-9 30-9 21.89 67.561 68.084 Flow (q) from Route 36 10,-0 Pe Pv CM 4.2600 514.91 11.59 120 0.057560 5,-0 Pt 0.288 77 78 30-9 30-9 26.00 68.084 68.372 Flow (q) from Route 37 5'-0 Pe Pv CM 6.3570 514.91 5.20 120 0.008194 5'-0 Pt 0.041 78 54 30-9 30-9 68.372 68.413 5-0 Pe Pv =...... Route 16 ..... ©M.E.P.CAD, Inc. AutoSPRlNK2U18v14.4.5.0 9/11/2020 10:01:12AM Page 12 dkydraulic Analysis Job Number: 20-1830-04 Renort Derintinn FM HC-2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary DY 2.1570 53.77 4.72 120 0.024227 135-8 Pt 4.390 15 56 309 30-9 57.504 61.894 P0(12-31/.) 2fT(10-51/2), P0(12-31/2) 45-6% 181-2% Pe Pv 0.000 =. ..... Route 17 ..... DY 2.1570 47.42 4.16 120 0.019201 135-8 Pf 3.479 16 57 30-9 30-9 58.451 61.930 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-61/2 18121/2 Pe Pv 0.000 Route 18 ..... DY 2.1570 41.51 3.64 120 0.015010 135-8 Pt 2.720 17 58 30-9 30-9 59.277 61.997 P0(12-3%) 2fT(10-5%), P0(12-3---l%) 45-61/2 181-21/2 Pe Pv 0.000 =. ..... Route 19 ..... DY 2.1570 36.04 3.16 120 0.011559 135-8 Pt 2.095 18 59 30-9 30-9 60.006 62.100 P0(12-3%) 2fT(10-51/2), P0(12-3%) 45-61/2 181-2% Pe Pv 0.000 Route 20 ..... DY 2.1570 31.02 2.72 120 0.008756 135-8 Pf 1.587 19 60 30-9 30-9 60.653 62.240 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-6% 181-2% Pe Pv 0.000 Route 21 ..... DY 2.1570 26.43 2.32 120 0.006511 135-8 Pt 1.180 20 61 30-9 30-9 61.235 62.415 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-6% 181-2% Pe Pv 0.000 = ..... Route 22 ..... DY 2.1570 22.27 1,96 120 0.004745 135-8 Pt 0.860 21 62 30-9 30-9 61.762 62.622 P0(12-3%) 2fr(10-51/2), P0(12-31/.) 45-61/2 181-2% Pc Pv 0.000 Route 23 ..... DY 2.1570 18.55 1.63 120 0.003383 J 135-8 Pt 0.613 22 63 30-9 30-9 62.247 62.860 P0(12-31/.) 2fT(10-5%), P0(12-3%) 45-61/2 181-2% Pc Pv 0.000 Route 24 ..... DY 2.1570 15.26 1.34 120 0.002357 135-8 Pt 0.427 23 64 30-9 30-9 62.696 63.123 P0(12-3%) 2fT(10'-5%), P0(12-3%)--1 45-6% 181-2% Pc Pv 0.000 Route 25 ..... DY 2.1570 12.41 1.39 120 0.001608 1 135-8 Pt 0.291 24 65 30-9 30-9 63.118 63.409 P0(12-31/2) 2fT(10-5%), P0(12-3%) 45-6% 181-2% Pc Pv 0.000 = ..... Route 26 ..... DY 2.1570 10.03 0.88 120 0.001085 135-8 Pf 0.197 25 ' 66 30-9 30-9 63.518 63.714 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-61/2 181-21/2 Pc Pv 0.000 =. ..... Route 27 ..... DY 2.1570 8.19 0.72 120 0.000745 135-8 Pt 0.135 26 67 30-9 30-9 63.900 64.035 P0(12-3%) 2fT(10'-51/2), P0(12-3%) 45-6% 181-2% Pc Pv 0.000 Route 28 ..... DY 2.1570 6.97 0.61 120 0.000553 1 135-8 Pt 0.100 27 68 30-9 30-9 64.268 64.369 P0(12-3%) 2fT(1051/,), P0(12-3%) 45-61/2 181-2% Pc Pv 0.000 Route 29 ..... DY 2.1570 6.51 0.57 120 0.000488 135-8 Pt 0.088 28 69 30-9 30-9 64.625 64.714 P0(12-3%) 2fT(10-5%), P0(12-3%) 45-6% 181-2% Pc Pv 0.000 Route 30 ..... DY 2.1570 6.89 0.60 120 0.000541 135-8 Pt 0.098 29 70 30-9 30-9 64.971 65.069 P0(12-3%) 2fT(10'-51/2), P0(12-31/2) 45-61/2 181-21/2 Pc Pv 0.000 -Route 31 ..... DY 2.1570 8.04 0.71 120 0.000720 135-8 Pt 0.130 30 71 30-9 30-9 65.306 65.436 P0(12-3%) 2fT(10-5%), P0(12-31/2) 45-6% 181-2% Re Pv 0.000 Route 32 ..... DY 2.1570 9.83 0.86 120 0.001044 1 135-8 Pt 0.189 31 72 30-9 30-9 65.628 65.817 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-6% 181-2% Pc Pv 0.000 Route 33 ..... .,©M.E.P.CAD, Inc. AutoSPRlNK 2018 04.4.5.0 9/11/2020 10:01:12AM Page 13 1111Hydraulic Analysis Job Number: 20-1830-04 Report Description: FM HC-2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary DY 2.1570 12.16 1.07 120 0.001547 135-8 Pt 0.280 32 73 30-9 30-9 65.935 66.215 P0(12-3%) 2fT(10'-51/.), P0(12-31/i) 45-6% 181-2% Pe Pv 0.000 =. ..... Route 34 ..... DY 2.1570 14.96 1.31 120 0.002272 135-8 Pf 0.412 33 74 30-9 30-9 66.223 66.634 P0(12-3%) 21T(10-5%), P0(12-3%) 45-6% 181-2% Pe Pv 0.000 =. ..... Route 35 ..... DY 2.1570 18.21 1.60 120 0.003268 135-8 Pf 0.592 34 75 30-9 30-9 66.489 67.081 P0(12-31/z) 2fT(10-51/1), P0(12-3%) 45-6% 181-2% Pe Pv 0.000 Route 36 ..... DY 2.1570 21.89 1.92 120 0.004594 135-8 Pt 0.832 35 76 30-9 30-9 66.729 67.561 P0(12-3%) 2fT(10-5%), P0(12-3%) 45-61/2 181-2% Pe Pv 0.000 Route 37 ..... DY 2.1570 26.00 2.28 120 0.006317 135-8 Pt 1.145 36 77 30-9 30-9 66.940 68.084 P0(12-3%) 2fT(10-5%), P0(12-3%) 45-6% 181-2% Pe Pv 0.000 Route 38 ..... DY 2.1570 28.67 2.52 120 0.007570 135-8 Pf 1.372 38 54 30-9 30-9 67.041 68.413 P0(12-3%) 2fT(10-51/2), P0(12-31/2) 45-6% 181-2'/2 Pe Pv =. ..... Route 39 ..... DY 2.1570 29.45 2.59 120 0.007956 135-8 Pt 1.442 39 53 30-9 30-9 67.062 68.504 P0(12-31/.) 2fT(10'-51/2), P0(12-3%) 45-61/2 181-21/2 Pe Pv =... ... Route 4O ..... DY 2.1570 30.36 2.67 120 0.008417 135-8 Pt 1.525 40 52 30-9 30-9 67.078 68.603 P0(12-31/2) 2fT(10-5%), P0(12-31/2) 45-6% 181-2% Pe Pv =. ..... Route 41 ..... DY 2.1570 31.99 2.81 120 0.009271 135-8 Pt 1.623 41 51 30-9 30-9 67.091 68.713 P0(12-3%) fE(4-31/2), fT(10-51/.), P0(12-3 '/2) 394% 175-0% Pe Pv Route 42 ..... DY 2.1570 38.82 3.41 120 0.013258 111-2 Pt 1.996 44 48 30-9 30-9 67.118 69.114 P0(12-31/2) tE(4'-31/,), fl(10'-S%), P0(12-3 %) 394% 150-7 Pe Pv =. ..... Route 43 ..... DY 2.1570 36.14 3.17 120 0.011614 120-2 Pt 1.853 43 49 30-9 30-9 67.114 68.967 P0(12-3%) fE(4-31/2), fT(10-51/2), P0(12-3 1/2 39-4% 159-7 Pc Pv Route 44 ..... DY 2.1570 33.77 2.97 120 0.010248 129-21/2 Pt 1.727 42 50 30-9 30-9 67.107 68.834 P0(12-31/2) tE(4-31/2), fT(10'-S%), P0(12-3 39-41/2 168-7 Pe Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule 40 Steel Pipe Inside Diameter 4.87 - ) - Factor C Value Multiplier Value 0C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 (,©M.E.P.CAD, Inc. AutoSPRlNK 2018 v14.4.5.0 9/11/2020 10:01:12AM Page 14 ~jjljHydraufic Analys I Job Number: 20-1830-04 repon uescription: -M hL-Z Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge g gp m BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DelV Deluge Valve SP Sprig i DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point n a pipe E 90° Elbow UG Underground Pt Pressure loss due to friction between points EE 450 Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 221/.* Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection tE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. AutoSPRlNK 2018 04.4.5.0 9/11/2020 10:01:12AM Page 15 III Riser Tag Job THERMO FISHER MEZZANINE 5781 VAN ALLEN WAY CARLSBAD, CA 92008 Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K-Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand At Base Of Riser (BOR) Total Demand Flow(gpm): Pressure(psi): Job Number: 20-1830-04 ort Description: FM HC-2 FM HC-2 692 27 8 0 0.200gpm/ft2 0.304gpm/ft2 2500.00ft2 (Actual 2591 .47ft2) 788.03 83.973 Water Supply Information At Time Of Design Static Pressure(psi): 117.900 Residual Pressure(psi): 97.200 Supply Flow(gpm): 2700.00 Total Demand Flow(gpm): 1038.03 Total Demand Pressure(psi): 96.459 ,© M.E.P.CAD, Inc. jAutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:13AM Page 16 ©M.E.P.CAD, Inc. Us AutoSPRINK 2018 04.4.5.0 9/11/2020 10:01:15AM Page 17 SEISMIC CALCULATIONS TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: Thermo Fisher Mezzanine Address: 13630 Danielson Street Poway, CA 92064 FaON 5781 Van Allen Way Phone: 858-513-4949 Carlsbad, CA 92008 Licence: C-16 588039 Job #20.1830-04 Calculations based on 2016 NFPA Pamphlet #13 Brace Information TOLCO TM Brace Components Maximum Brace Length TO" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig. 1001 Clamp 1200 lbs (544 kg) 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 450 Min. *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail LJR Value 200 Max Horizontal Load 1310 lbs (594 kg) TOLCO FIG. 98 UNIVERSAL SWAY BRACE Other Requirements - FM Approved Loads ATTACHMENT 0 STEEL PIPE / Fastener Information Orientation to Connecting Surface NFPA Type H Fastener s / / Type Bolt t-+ Diameter 3/8in. (10 mm) Length N/A TOLCO FIG. 1001 FAST CLAMP / Maximum Load 1035 lbs (469 kg) - Brace Identification on Plans 3 Lateral Prying Factor N/A Brace Type Lateral [X] Longitudinal [ ] 4-Way [1 Sprinkler System Load Calculation (Fpw = CpWp) Cp = 0.5316 Diameter Type Length Total Length Weight Per Unit Length Total Weight 3" (80 mm) Sch. 10 30 ft (9.1 m) 30 ft (9.1 m) 7.94 lb/ft (11.82 kg/m) 238 lbs (108 kg) 1.5(40mm) Sch. 10 101 ft(30.8rn) 101 ft(30.8m) 3.04 lb/ft (4.52kg/m) 307 lbs (139kg) Subtotal Weight 545 lbs (247 kg) Wp (incl. 15%) 627 lbs (284 kg) Main Size - Type/Sch. Sch. 10 Spacing (ft) 30 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 333 lbs (151 kg) 633 lb (287 kg) JOdL, versiulu o use or ujLDrece- is suoject to terms ana conatuons per me end user license agreement TOLBraceTM Seismic Calculations Thermo Fisher Mezzanine 5781 Van Allen Way Brace Identification Brace Type (Per NFPA#13) Braced Pipe (ft) Spacing of Brace Orientation of Brace Bracing Material Maximum Brace Length Slenderness Ratio used for Load Calculation Twe Angle of Brace for Calculation Type of Fastener Length of Fastener Job #20-1830-04 ELI ftwens 8iinessWadda 3 Lateral NFPA Type H 3" Sch.10 Steel Pipe 30'0" (9.14 m) Lateral 1" Sch.40 7'0" (2.13 m) 200 45" 3/8 (10mm) Bolt N/A Summary of Pipe within Zone of Influence 3" Sch.10 Steel Pipe (76.2 mm) 30 ft (9.1 m) 1.5' Sch.10 Steel Pipe (38.1 mm) 101 ft (30.8 m) G-Factor Used 0.5316 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 333 lbs (151 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 1035 lbs (469 kg) Fig. 1001 Clamp 1200 lbs (544 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member Steel C Channel Calculations prepared by WFP *The description of the Structural Member is for informational purposes only. T01-13race"0 software calculates the brace assembly only, not the structure it is attached to, Calculated with 1OLSrace'0 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Western Fire Protection Project Address: Therrno Fisher Mezzanine Address: 13630 Danielson Street Poway, CA 92064 5781 Van Allen Way Phone: 858-5134949 Carlsbad, CA 92008 Licence: C-16 588039 Job #20-1830-04 Calculations based on 2016 NFPA Pamph let #13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'0" (2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 11. Fig. 4LA Clamp 970 lbs (440 kg) 970 lbs (440 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) 1970 lbs (894 kg) Type of Brace Scft40 See Fastener Information Angle of Brace 450 Mm. *Calculation Based on CONCENTRIC Loading Please Note: These calculations are for TOLCOTM components only. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42(11 mm) Seismic Brace Assembly Detail URValue 200 Max Horizontal Load 1310 lbs (594 kg) Other Requirements - FM Approved Loads Ul-AY Fastener Information Orientation to Connecting Surface NFPA Type E Fastener Type Boft Diameter 3/81n. (10 mm) A Length N/A Maximum Load 1200 lbs (544 kg) mats FKZ&A Brace Identification on Plans 3 Longitudinal Prying Factor N/A Brace Type Lateral[ ] Longitudinal [X] 4-Way Sprinkler System Load Calculation (Fpw = CpWp) Cp 0.5316 Diameter Type Length Total Length Weight Per Unit Length Total Weight 3(80mm) Sch. 10 55ft(16.8m) 55ft(16.8m) 7.94 lb/ft (11.82kg/m) 437 lbs (198kg) Subtotal Weight 437 lbs (198 kg) Wp (incl. 15%) 503 lbs (228 kg) Main Size Type/Sch. Spacing (ft) 3" Sch. 10 65 I Total (Fpw) Maximum Fpw per 9.3.5.5.2 (if applicable) 267 lbs (121 kg) N/A IULBF5C version ai, use or i QLrace" is subject to terms and conditions per tile end user license agreement TOLBraceTM Seismic Calculations Thermo Fisher Mezzanine 5781 Van Allen Way Brace Identification Brace Type (Per NFPA#13) Braced Pipe (ft) Spacing of Brace Orientation of Brace Bracing Material Maximum Brace Length Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener Job # 20-183004 3 Longitudinal NFPA Type E 3" Sch.10 Steel Pipe 55 0(16.76 m) Longitudinal 1" Sch.40 7'0" (2.13 m) 200 450 3/8 (10mm) Bolt N/A [cN F~Kvmg Business Wà Summary of Pipe within Zone of Influence 3' Sch.1O Steel Pipe (76.2 mm) 155 ft (16.8 m) G-Factor Used 0.5316 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 267 lbs (121 kg) Material Capacity 1310 lbs (594 kg) Fastener Capacity 1200 lbs (544 kg) Fig. 41-A Clamp 970 lbs (440 kg) Fig.980 Universal Swivel 1970 lbs (894 kg) Structural Member Steel C Channel Calculations prepared by WFP * The description of the Structural Member is for informational purposes only. T01-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with TOLBrac&0 8 Visit us at vi.tolco.com