Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
786 GRAND AVE; ; FPC2021-0113; Permit
(?ity of Carlsbad Print Date: 10/17/2024 Job Address: 786 GRAND AVE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4*: 2033020400 Track 4*: Valuation: $0.00 Lot 4*: Occupancy Group: Project 4*: #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Plan Check 4*: Permit No: FPC2021-0113 Status: Closed - Finaled Applied: 06/22/2021 Issued: 07/29/2021 Finaled Close Out: 10/11/2024 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: GRAND JEFFERSON -NEW FIRE ALARM SYSTEM (NEW CONSTRUCTION, 4 STORY, MIXED USE, ADDRESSABLE, 81 DEVICES) Applicant: FPContractor: SYMONS FIRE PROTECTION INC SYMONS FIRE PROTECTION INC MICHAEL GULINO 9475 CHESAPEAKE DR 12155 PAINE PL SAN DIEGO, CA 92123-1336 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov _rF MIe j7v-Ar Lj ERN =1 Fire Alarm System Complete Material Submittal Prepared for: THE GRAND JEFFERSON 786 GRAND AVENUE, CARLSBAD, CA JUNE 15th7 2021 9475 Chesapeake Drive San Diego, CA 92064 (619) 588-6364 Fax (619) 588-6805 CA Lic. #682025 , K] .Iquo TABLE OF CONTENTS - FIRE ALARM SYSTEM SUBMITTAL 1. FIRE ALARM SILENT KNIGHT - FIRE ALARM CONTROL PANEL - SK-6700 SILENT KNIGHT - FIRE ALARM REMOTE ANNUNCIATOR - SK-6860 INTERSTATE - FIRE ALARM BATTERIES 8Ah - 12V - SLA-1075 SPACE AGE— FIRE ALARM DOCUMENT CABINET - ACE- il TELGUARD - FIRE ALARM CELLULAR DIALER - TG7-FS SILENT KNIGHT - REMOTE POWER SUPPLY - SK-5499 SILENT KNIGHT - SINGLE INPUT MONITOR MODULE - SK-MONIOTR SILENT KNIGHT - DUAL INPUT MONITOR MODULE - SK-MONIOTR2 SILENT KNIGHT - RELAY MODULE - SK-RELAY FIRE-LITE - LOW VOLTAGE RELAY - PAM-1 SILENT KNIGHT - FIRE ALARM PULL STATION - SK-PULL-DA SILENT KNIGHT —FIRE ALARM SMOKE DETECTOR - SK-PHOTO-W SILENT KNIGHT —FIRE ALARM HEAT DETECTOR - SK-HEAT-W SYSTEM SENSOR —OUTDOOR WALL MOUNTED - HORN/STROBE - P2RK SYSTEM SENSOR —OUTDOOR CEILING MOUNTED - HORN/STROBE - PC2RHK SYSTEM SENSOR —WALL MOUNTED - HORN/STROBE - P2WL SYSTEM SENSOR —CEILING MOUNTED - HORN/STROBE - PC2WL SYSTEM SENSOR —LOW FREQUENCY - HORN - HWL-LF 9475 Chesapeake Drive San Diego, CA 92064 c (619) 588-6364 Fax (619) 588-6805 0 CA Lic. #682025 6700 6700 Addressable Fire Alarm Control Par Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can suppOrt 50 System Sensor® (SK) sensors and 50 SK modules or 50 Hochiki® (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the The 6700 supports a variety of devices, including 6860 remote annunciator which also has four programmable function the 6860, 5860, and 6855 remote annunciators, buttons to help automate tasks and reduce time spent at the panel. 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, SWI FT® wireless compatibility provides options for wireless detection 5895XL power module, and SK or SD devices. through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where newwiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS Capable of providing up to 100 points to satisfy smaller installation needs Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models Convenient field-u pgradeable firmware Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting 6860 annunciator with a 4 x 40 large display Four user- programmable buttons minimize time spent executing complex or routine tasks Built-in USB interface for convenient and quick programming Programmable date setting for automatic and convenient Daylight Saving Time changes JumpStart® auto programming reduces installation time 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC Loops support multiple device types, maintenance alerts, and a built-insensortesttocomplywith NFPA 72 calibration testing requirements. INDICATOR LIGHTS General Alarm (Red): Flashes if in alarm; solid when alarm is silenced Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4-to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart® auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows® software system configuration tool. to create a detailed Bill of Material(BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft® Windows®. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860: 4x4O LCD remote fire annunciator (4 lines and up to 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED/ 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.silentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. UL Listed: S2766 CSFM 7165-0559:0501 FDNYCOA#6250 annunciators give you on-site access to 160 characters) per system; four current system programming. programmable buttons Programming can also be accomplished 5860: 4x20 LCD remote fire using the Windows®-based Honeywell annunciator. 5860 is gray; 5860R is red Fire Software Suite (HFSS) program. 6855: 4x2O LCD remote fire annunciator Page 2 of 4— 351607:13 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1351F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (1351F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1901F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(-IV): 6 base for SK-W Series B21OLP: 6 mounting base B501(-BL,-IV,-WHITE): 4"flangeless base B501: 4 Flangeless mounting base B200S(-IV,-WH): Intelligent sounder base B200S: Intelligent sounder base B200S-LF(-IV,-WH): Low-Frequency intelligent sounder base B200S-LF: Low-frequency intelligent sounder base B224RB(-IV,-WH): Relay base B224RB: Relay base B224B1(-IV,--WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6 base SD505-61B: Addressable 6 short circuit isolator base SD505-6RB: Addressable 6 relay base SD505-6SB: Addressable 6 sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the 5D505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. S0505-DUCTR: Addressable Duct Dtector housing with relay base. SD505-HEAT: Absolute temperature heat detectcr. Trip point range from 135°F-150°F (0°C-37°C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sulentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and B510W4 base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and B510W4 base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and B510W4 base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10"H x 6" D (406mm W 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4— 351607:13 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Flexput®, Honeywell®, Overall Dimensions: 12.71"W 15.12 H x 3.33"D Two programmable circuits which can be JumpStart®, Silent Knight®, SWIFT®, and System Weight: 15 lbs programmed individually as: Sensor® are registered Color: Red NACs: 2.5A @ 27.4VDC per circuit, power-limited trademarks of Honeywell (with a panel maximum current of 2.5A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits: 2.5A ® 27.4VDC per Hochiki® isa registered Operating Temperature: 32°F to 120°F (0°C to circuit, power-limited trademark of Hochiki 49°C) Corporation. Microsoft® Humidity: 0 to 930/o relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) and Windows® are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING: See the product manual for wiring details This document is not 6700 Primary AC: 120 VAC @ 60 Hz, 1.5A Total intended to be used for Accessory Load: 2.5A @ 27.4 VDC power-limited installation purposes We try to keep our product Standby Current: 165mA information up-to Alarm Current: 310mA date and accurate. We Battery Charging Capacity: 7 to 35AH cannot cover all specific applications Battery Size: 74H max. allowed in control panel or anticipate all requirements All cabinet. Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet, to change without notice. For Technical Support, call 800-446-6444. Honeywell Sitént Knight 12 Clintonville Road Northford, CT 06472 DJorrneellEI 800-328-0103 351607 I B 09/18 'r www.silentknight.com © 2018 Honeywell International Inc. KJ1GH•r p ), tNI I] I I4I(1I i Remote Annunciator The 6860 remote annunciator can be used to view system status indicators for Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere within the system. It provides a convenient way to view system status indicators. The 6860 comes in a locked, key controlled cabinet - combining security with easy access. It does not require a code or firefighter's key to silence or reset a panel, and also has convenient separate scroll buttons for alarm, supervisory and trouble conditions. The remote annunciator communicates With the main fire alarm control panel through an RS-485 connection. The 6860 has a large 160 character, Ax 40 display and four programmable buttons. These features provide more options for set-up and operation when compared to similar remote annunciators. 6860 The 6860 can be surface or flush mounted. The RA-100TR trim ring can be used for surface mounts. COMPATIBILITY The 6860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel. with up to 1,110 addressabLe points 6820EVS: Addressable fire alarm control panel with an emergency voice system, up to 1,110 addressable points 6808: Addressable fire alarm control pane[ with up to 198 addressable points 6700: Addressable fire alarm control pane[ with up to 100 addressable points FEATURES & BENEFITS Four line LCD display with 40 characters per line; 160 characters provides ample space for communicating operating messages Larger keypad buttons makes iteasierto maneuver for system reset and silencing Initiate and end fire drills with a single key press Easily view current status by alarms, supervisories, or troubles On-board piezo sounder audibly indicates alarms, troubles, and supervisories Uses the RS-485 SBUS to interface with the panel Five status LEDs make it easier to monitor and respond to status changes. They include: Alarm, Supervisory, Silence and AC Power indicators. Accommodates wiring Lengths up to 6000 ft. from the control panel for added design and install flexibility System access through a user code or firefighter's key Support for simultaneous use of multiple 6860s Can be flush or surface mounted. Trim ring available for surface mounting. Four programmable function keys for for improved efficiencies and time-savings; frees-up time spent at the panel Comfortable tactical feel and clear audible confirmation supports accurate programming and easy operation 6860 Technical Specifications Review Events Individually by Alarms, Supervisories, or Troubles 160 Character Large Buttons for Stem Silence, Reset, vent Acknowledge, and Fire Drill rgonomic ;ned Keypad len door is closed) 6,860 FEATURES For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft. Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. PHYSICAL Flush Mount Outside wait: 12.25W x 11.5"H x 7/8"D (31.1W x 29.2H x 2.20 cm) Inside watt: 9-3/8"W x 8-3/8"H x 20 (23.8W x 21.3H x 5.10 cm) Surface Mount: (Including Trim Ring) 12.25W x 11.5"H x 3"D (31.1W x 29.2H x 2.20 cm) ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 930/o relative humidity (non- condensing) ELECTRICAL Operating Voltage: 24VDC Standby Current: 25mA Alarm Current: 50m4 ORDERING INFORMATION 6860: Remote Annunciator. Four line (4x40) LCD annunciator. Red ACCESSORIES RA-100TR: Red surface mount trim ring AGENCY LISTINGS AND APPROVALS UL listed CSFM # 7165-0559:0500 NFPA 72 FM approved FDNY COA approved For more information Learn more about Silent Knights 6860 and other products available by visiting www.SilentKnight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 800.328.0103 www.honeywell.com 3516121 Al 11/17 © 2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0501 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interlace 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerl'ace Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued; July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME, F.P.E. Fire Engineering Division Listing No. 7165-0559:0501 Page 2 of 2 and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division STA1ET ]4JERIES General Purpose Outrageously Dependable' The Power of a Perfect Fit Interstate's SLA battery family powers more than devices. They empower the people who use them-and choose them. Part # SLA0826 volts 4V Ah Capacity* 4.5 Ah 1.89 A 2.07 Dimensions H 3.70 .. 3.94 Terminal Fl SLA0833 4V 8Ah 358 197 398 398 F2 SLA0836 4V 10Ah 4.02 1.97 3.70 3.94 F2 SLA0855 6V llAh 201 165 2.01. 224 Fl SLA0865 6V 12Ah 382 098 205 224 Fl SLA0184 6V 20Ah 1..69 146 299 299 Fl SLA0902 6V 2.8Ah 2.60 1.30 3.82 4.06 Fl SLA0885 6V 32Ah 528 134 236 260 Fl SLA0905 6V 45Ah 276 185 402 417 Fl SLA0906 6V 5 264 264 378 398 Fl SLA0916 6V 5 264 264 382 4.6.5 SPR SLA0935 6V 7Ah 386 220 402 402 Fl SLA0925 6V 7 Ah 5.94 1.34 3.70 3.94 Fl SLA0945 6V 9Ah 386 220 465 472 Fl SLA0955 6V 10 5.94 1.97 3.70 3.90 Fl SLA0959 6V 12 5.914 197 370 390 F2 SLA0961 6V 12 594 197 370 390 Fl SLA0986 6V 20 6.18 3.27 4.92 4.92 NB SLA0993 6V 42 Ah 6.38 3.46 6.42 6.69 F2 SLA0994 6V 42 638 346 642 685 NB SLA0988 8V 3.2Ah 5.28 1.42 2.48 2.72 Fl SLA1 000 12V 700 mAh 3.78 098 2.44 2.44 Plug SLA1005 12V 1.3Ah 3.82 1.69 2.09 2.28 Fl SLA0218 12V 2 276 189 386 409 Fl SLA1020 12V 2 A 591 079 354 354 Fl SLA1016 12V 2.3 Ah 7.01 1.38 2.36 2.60 Fl 5LA1015 12V 2.3Ah 7.01 1.34 2.36 2.36 Fl SLA1022 12V 2.9 Ah 3.11 2.20 3.90 4.21 Fl S LAO O77 12V Z9 Ah 3.11 2.20 3.90 4.13 Fl SLA1 042 12V 3 Ah 5.28 2.64 2.36 2.60 F2 SLA1035 12V 3.5 Ah 5.28 2.64 2.36 2.60 Fl 5LA1041 12V 3.5 Ah 5.28 2.64 2.36 2.60 Fl SLA1055 12V 5 Ah 3.54 2.76 3.98 4.21 Fl SLA1056 12V 5 Ah 3.54 2.76 3.94 4.21 F2 SLA1075 12V 8 A 5.94 2.56 3.70 3.94 Fl SLA1079 12V 8 A 5.94 2.56 3.70 3.94 F2 SLA1 080 12V 7.5 Ah 5.94 2.56 3.70 3.90 F2 SLA1097 12V 10Ah 5.94 2.56 4.37 4.61 F2 SLA1104 12V 12 Ah 5.94 3.86 3.66 3.86 F2 SLA1105 12V 12 Ah 5.94 3.86 3.66 3.86 Fl SLA1098 12V 12 Ah 5.94 3.86 3.66 4.09 NB SLA1116 12V 18 Ah 7.13 2.99 6.57 6.57 NB SLA1115 12V 18 Ah 7.13 2.99 6.57 6.57 F2 SLA1146 12V 26 Ah 6.50 6.89 4.88 4.88 NB SLA1150 12V 30 Ah 6.50 4.88 6.89 6.89 NB SLA1156 12V 35 Ah 7.72 5.12 6.22 6.65 INS SLA1155 12V 35 Ah 7.76 5.16 6.26 7.09 Flag SLA1161 12V 44 Ah 7.76 6.50 6.69 6.69 INS SLA1165 12V 55 Ah 9.02 5.43 8.07 8.90 Flag SLA1160 12V 55 Ah 9.02 5.43 8.27 9.25 NB - Reversed SLA1180 12V 65 Ah 13.70 6.61 7.01 7.01 INS 5LA1175 12V 75 Ah 10.20 6.61 8.35 8.98 Flag SLA1185 12V 100Ah 12.09 6.61 8.19 9.06 Flag 5LA1189 12V 100Ah 12.09 6.61 8.19 8.43 INS 02019 Interstate Batteries I ABC-985 ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Space Age Electronics, Inc. MadeIS.A. R*RE7/ NFPA COMPANY 800.486.1723 Toll Free MEPAMER 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! hzISPACEAGE Lt =ol' ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge The enclosure will supply 4 mounting holes Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure A legend sheet will be permanently attached to the door for system required documentation key contacts and system information The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel USB Storage Interface Requires Standard USB-B Connector property information CrotlllctIont end ApprovIr 16.1 Syrt,r, tn,*oIl,tion Contractor: 16,5 Authority bAng Jurisdiction: saombd.s Equipment Infom,011on Miflinton, Required Doconrontatlon (Sit-FUN) eFocm .fld.m1..toolnuroo -rn-rn--- .0 . II 00 I. a$ln00.0.neeepAreto 12 010*2 (0-202) 00100. Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doe # ED0479 for legal disclaimer ED0549 LT1 0559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCXIA 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any daims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division M 44 TELGUARD TG-7FS LTE-V P/N: TG7LVFO1 CELLULAR ALARM -- COMMUNICATORU FOR LIE NETWORKS COMMERCIAL FIRE PRODUCT FEATURES I Certified for use on Verizon's LTE network for long, sunset-free installation. I- Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LIE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS LTE-V CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD Transmit Power: 200mW in all bands. Power Consumption: 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. I -- ---a -. g oansceiver. LTE Bands 4&13 Antenna: 9" dipole with 2dBi gain 12 ft of cable and universal mounting bracket. FCC part 15, 27 and 68 compliant. __ .. TG-7FS LTE-V: 7.5" H x 11.5" W x 3.5' D. Shipping Weight:81bs. Operating Environment: 0°C to +50'C; up to 95% humidity - (non-condensing). - - (f if LTE 11-r~ LTE-V C Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-O: High gain directional antenna. EXDL-0: External antenna. Full data reporting. Automatic self-test (60 mm. & daily). Power supply ith battery harness. Locking, red metal enclosure.- Two programmble supervisory, trip outputs. Supports virtually all alarm formats (Contact ID, S1A2, and others), using dial capture for.universal panel compatibility. Telephone line monitor built-in, with Standard Line Security. UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 • central station burglar alarm units; Line security,•servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems For the most current product specifications and UL Listings visit www.Telguard.com, SECURITY - SIGNALING 0 ONIC -t~svy'. `c-T,`rrY ver'7—on NFPA® ' 1, NETWORK God LISTED INTEATIONAL CERTIFIED Telguard, a Division of Telular corporation 3225 Cumberland Blvd SE Suite 300 • Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com • copyright ©2017 Teliiar Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA001, TG7LAA01, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee s printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19gt This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division