5909 SEA OTTER PL; 100; FPC2017-0228; Permit
rCity of Carlsbad Print Date: 10/24/2024 Job Address: 5909 SEA OTTER PL, # 100, CARLSBAD, CA 92010-6674 Permit Type: FIRE-Construction Commercial Work Class: Parcel U: 2090820900 Track U: Valuation: $1,591,432.67 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2017-0228 Status: Closed - Finaled Fixed Extinguishing Syste Applied: 08/09/2017 Issued: 08/29/2017 Finaled Close Out: 04/08/2021 Final Inspection: INSPECTOR: Wong, Cindy Fieri, Dominic Project Title: Description: SYNTERACT OFFICE (SERVER ROOM 117) -FIRE SUPPRESSION SYSTEM FPContractor: HCI SYSTEMS INC 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 (909) 628-7773 FEE AMOUNT FIRE Special Extinguishing System $568.00 Total Fees: $568.00 Total Payments To Date: $568.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov *Fire alarm & Clean Agent system cut sheets & California State Fire Marshall Listing sheets foi: - SYNTERACT HCR 5909 SEA OTTER PLACE CARLSBAD, CA 92010 goOw\ 'fl FPC20I7-0228 59O9 SEA OTTER PL UNITIOO FILE COPY 1. r.. 1354 PARKSIDE PLACE ONTARIO, CA 91761 (909) 628-7773 ! The AUTOPULSE 542R is a six-zone Agent Releasing Control Panel for single and dual hazard agent releasing applications. The AUTOPULSE 542R provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The AUTOPULSE 542R is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the panel Indicating the need for clean- ing and a supervisory 1reeze' signal when the ambient temperature falls below the detector rating of approximately 45 °F (7 °C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The AUTOPULSE 542R supervises all wiring, AC voltage, batery charger and battery level. Activation of a compatible smoke detector or any normally-open fire alarm Initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the panel, activate the panel alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The AUTOPULSE 542R(E) releasing panel offers the same features as the AUTOPULSE 542R but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and 220/240 VAC versions of the panels. Designed for agent releasing standards NFPA 12, 12A, 12B and 2001 Disable/Enable control per input zone and output zone Extensive transient protection Dual hazard operation Manual release/Abort combination zone Adjustable pre-discharge, discharge and waterflow delay timers Cross-zone (double-interlock) capability Six programmable Style B (Class B) IDCs (Initiating Device Circuit) System Sensor P series detector compatible Four programmable Style Y (Class B) output circuits - (special appli- cation power) Strobe synchronization - System Sensor - Wheelock - Gentex - Faraday - Amseco Three programmable Form-C relays Latching option for relays a Pre-discharge relay option 7.0 amps total 24 VDC output current a Resettable and non-resettable output power Built-in Programmer 007701 I Short circuit RAC supervision ANN-BUS for connection to optional devices (up to eight total of any of the following): - ANN-80 Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module 80-character LCD display (backlit) Real-time clock/calendar with daylight savings time control I History log with 256 event storage Piezo sounder for alarm, trouble and supervisory I 24 volt operation Low AC voltage sense I Outputs programmable for: - Releasing Circuits a NACs programmable for - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder - Stage Silenceable Option - Cross Zone Pre-discharge - Cross Zone Discharge I Automatic battery charger with charger supervision U Optional Dress Panel DP-51050 (red) U Optional Trim Ring TR-CE (red) for semi-flush cabinet mounting Optional CAC-5X Class A Converter Module for Outputs and lDCs U Optional 4XTM-F Municipal Box Transmitter Module U Optional Digital Alarm Communicators (411, 411 LID, 411UDAC) -FEA% PROGRAMMING AND SOFTWARE: R Custom English labels (per point) may be manually entered or selected frOm an internal library file a Programmable Abort operation Three programmable Form-C relay outputs Eleven pre-programmed templates and one user-defined template Continuous fire protection during online programming at the front Panel a Program Check automatically catches common errors not linked to any zone or Input point III Selectable timer options for Discharge I and 2, and Pre-discharge 1 and 2 USER INTERFACE: Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings adjustments ANN-Bus for connection to remote annunciators a Audible or silent walk test capabilities Piezo sounder for alarm, trouble, and supervisory CONTROLS AND INDICATORS LED IllINDICATORS 1 FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) DISCHARGED (red) PRE-DISCHARGE (red indicator) a ABORT (yellow Indicator) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL AC Power - T91 a AUTOPULSE 542R: 120 VAC, 50/60 Hz, 2.3 amps AUTOPULSE 542R(E): 240 VAC, 50 Hz, 1.15 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation E Supervised, nonpower-limited Battery (sealed lead acid only) - J12: a Maximum Charging Circuit - Normal Fiat Charge: 27.6 VDC © 1.4 amp Supervised, nOnpower-limited a Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the panel cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55). a Minimum Battery Size: 7 Amp Hour Initiating Device Circuits - 104 and T86 a Alarm Zones 1 —5 on TB4 Alarm Zone 6 on TB6 a Supervised and power-limited circuitry a Style B (Class B) or Style Z (Class A) with optional converter module a Normal Operating Voltage: Nominal 20 VDC a Alarm Current, 15 mA minimum a Short Circuit Current: 40 mA maximum a Maximum Loop Resistance: 100 ohms (700 ohms for linear heat detection) a End-of-Line Resistor: 4.7K ohms, 1/2 watt m Standby Current: 4 mA Notification Appliance and Releasing Circuit(s) - TB5 and 107 Four output circuits Style Y (Class B) or Style Z (Class A) with optional converter module Special application power a Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC a Maximum Signaling Current: 7.0 amps (3.0 amps maximum per NAC) a End-of-Line Resistor: 4.7K ohms, 1/2 watt Maximum Wiring Voltage Drop: 2 VDC Refer to the Device Compatibility Document for compatible listed devices. Form-C Relays - Programmable —108 Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) a Relay Contact Ratings: —2 amps @ 30 VDC (resistive) - 0.5 amps © 30 VAC (resistive) Auxiliary Trouble Input - J6 The Auxiliary Trouble Input Is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral such as a power supply, which is compatible with open collector circuits. Special Application Resettable Power - TB9 a Operating Voltage: Nominal 24 VDC a Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors (see Note) a Power-limited circuitry Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC a Maximum Available Current: 500 mA (see Note) a Power-limited circuitry a Jumper selectable by JP31 for resettable or nonresettable power Note: Total current for resettable power, nonresettable power and output circuits must not exceed 7.0 amps. AUTOPULSE 542R: Six zone, 24 volt Agent Release Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard clean agent appli- cations. AUTOPULSE 542R(E): Same as above but allows connection to 220/240 VAC. CAC-5X: Class A Converter Module can be used to convert the Style B (Class B) initiating Device Circuits to Style D (Class A) and Style V (Class B) Output Circuits to Style Z (Class A). Note: Two Class A Convener modules are required to convert all tour Output Circuits and six Initiating Device Circuits. 4XTM-F: Transmitter Module provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. ANN-80: LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the panel LCD display. Recommended wire type is un-shielded. ANN-LED: Annunciator Module mounts in the DP-5105OLED Dress Panel and provides three LEDs for each zone: Alarm, Trouble and Supervisory. ANN-RLY: Relay Module, which can be mounted inside the cabinet. provides 10 programmable Form-C relays. ANN-SIPG: Serial/Parallel Printer Gateway module provides a connec- tion for a serial or parallel printer. PRN-6: Printer. ANN-hO: LED Driver Module provides connections to a user-supplied graphic annunciator. DP-51050: Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allowing access to the membrane switch panel. DP-510SOLED: Dress panel is available as an option. The dress panel restricts access to the system wiring while allowing access to the membrane switch panel. It also allows the installation of an optional ANN-LED annunciator module. TR-CE: Trim-ring (red) is available as an option. The trim-ring allows semi-flush mounting of the cabinet. BB-26: Battery box, holds up to two 26 Amp Hour batteries and CHG-75. BAT Series Batteries The listings and approvals below apply to the basic AUTOPULSE 542R and AUTOPULSE 542R(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S4935 FM: Approved CSFM: 7165-0595:118 MEA: 333-07-E Part No. Description 433607 AUTOPULSE 542R Agent Releasing Control Panel, 120 VAC 433608 AUTOPULSE 542R(E) Agent Releasing Control Panel, 220/240 VAC SYSTEM CAPACITY Annunciators: 8 ELECTRICAL SPECIFICATIONS AUTOPULSE 542R (FLPS-7 Power Supply): 120 VAC, 50/60 Hz, 2.3 amps AUTOPULSE 542R(E) (FLPS-7 Power Supply): 240 VAC, 50 HZ, 1.15 amps Wire Size: Minimum 14 AWG (2.0 mm2) with 600 V insulation, super- vised, nonpower-limited CABINET SPECIFICATIONS Door: 19.26 in. (489 mm) high x 16.82 in. (427 mm) wide x 0.72 in. (18 mm) deep Backbox: 19.00 in. (483 mm) high x 16,65 in. (423 mm) wide x 5.25 In. (133 mm) deep Trim Ring (TR- CE): 2200 in. (559 mm) high x 19.65 in. (499 mm) wide SHIPPING DIMENSIONS - Height: 20.00 in. (506 mm) - Width: 22.50 in. (572 mm) - Depth: 8.50 in. (216 mm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 32 to 120 °F (0 to 49 C) and at a relative humidity 93%:t 2% RH (non-condensing) at 90 °F ±3 °F (32 °C ±2 CC). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 60 to 80 ¶ (15 to 27 °C). NFPA STANDARDS - NFPA 12 CO2 Extinguishing Systems (High Pressure Only) - NFPA 12A Halon 1301 Extinguising Systems - NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) - NFPA 2001 Clean Agent Fire Extinguishing Systems tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright @ 2011 Tyco Fire Protection Products All rights reserved Form Products Marinette, WI 54143-2542 www.ansuI.com No. T-2010233 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0595:0118 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: ANSUL FIRE PROTECTIONI Stanton Street, Marinette, WI 54143-2542 Contact: Jennifer Milostan (715) 735-7411 Fax (715) 732-3634 Email: jmilostan@tycoint.com DESIGN: Model Autopulse 542DE and 542RE conventional fire alarm control unit. Each unit employ six programmable input circuits, four programmable output circuits, and three relay contact outputs for alarm, trouble, and supervisory signals. These units do not contain an integral digital alarm communicator transmitter (DACT). The "E" suffix represents 240 V ac 50 Hz rated units. Model Autopulse 542DE is intended for water release, deluge, and pre-action control. Model Autopulse 542RE is intended for agent release control. FLPS-7 Power Supply module 4XTM Transmitter module CAC-5X Converter module ANN-80 LCD Annunciator ANN-I I 0 LED Driver module ANN-LED Annunciator module ANN-RLY Relay module ANN-S/ PG Serial/Parallel printer module DP-51050 Dress panel DP-5I050LED Dress panel INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use as a pre action, deluge and agent releasing panel. Units also provide fire detection, signaling and protection features. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. XLF: 7165-0075:0216 09-21-07 mt This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or Installation criteria. Refer to llstees data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Detection and Control Components EA4-Pu 1 ,4ti 44-14 44-f--H ++*4444 Features Provide secondary power for control units Gelled electrolyte Sealed and maintenance free Overcharge protected Extended shelf life Easy handling with leak-proof construction Ruggedly constructed, high-impact ABS plastic case Long service life Compact design Applications PS series batteries provide secondary power for the AUTOPULSE control systems. Use these batteries to pro- vide backup power for control units. Select batteries based on current requirements for your system and the capacity of its charger. These batteries can be used over a temperature range of-76 OF to +140 OF (-60 °C to +60 °C). Description The sealed construction of the battery allows trouble-free, safe operation in any position. There is no need to add elec- trolyte, as gases generated during overcharge are recom- bined in a unique "Oxygen Cycle." The battery is sealed, leak-proof, and maintenance free. The case is made of ABS, a high-impact plastic resin (acrylonitrile butadiene styrene copolymer) with high resistance to chemicals and flammability. Shipping assemblies consist of two (2)12 VDC batteries pro- viding 24 VDC to the control system when connected in series. Technical Information PS Series Batteries (IQ-318, 10-636X-2,542R, 542D, Z10) CHARACTERISTIC DISCHARGE CURVES 6.5 I.. 13 6.0 -12 5 0 _Q .0. On 16 1. Ill I ~_M_wq 1 01 nommm%,, IS N W 01111 ilk 1111111111111M Wool ••miiuuiuii•i XMIN0120011001 4.0 I- 8 0 I-" MINUTES "I HOURS DISCHARGE TIME @ 68 'F (20 'C) 004544 EFFECT OF TEMPERATURE ON CAPACITY 10000 pp- -MEN ___ I - 0.1c 09069P M-00000-0-0.25C oll P new 0.6C 0- MEN P 0----ow -W ow 0 N .IR_I MI•BI U 32 50 68' 86° 104° 122° 140 (0) (10°) (20) (30) (40°) (50°) (601) TEMPERATURE 'F (C') 004845 120% 100% Q 80% ir 60% 6) O 40% 20% 0% .-4 14 (-20')(-lOi The capacity of a battery is the total amount of electrical energy available from a fully charged cell. Its value depends on the discharge current, the temperature during discharge, the final cutoff voltage and the general history of the battery. Capacity expressed in ampere-hours (AH), is the product of the current discharged and the length of discharge time. The rated capacity (C, where C = rated Capacity of the battery in AH) of the PS series batteries is measured by its perfor- mance over 20 hours of constant current discharge at a tem- perature of 68 OF (20 °C) to a cutoff voltage of 1.72 volts, per cell (10.32 V on a 12 V battery). For example: Model PS-1250, with a rated capacity of 5.0 AH, will deliver 250 milli-amps (1/20 of 4 AH, or 0.05C) for 20 hours before the voltage drops to 10.32 V (1.72 x 6 cells). PS SERIES BATTERIES SEALED RECHARGEABLE BATTERY 3-13 Technical Information (Continued) Rated 20 Hour Height over Capacity Discharge Length Width Height Terminal Weight @20 Hour Rate in. in. in. in. lb Model Rate (AH) (mA rate) (mm) (mm) (mm) (mm) (kg) PS-1270 7.0 325 5.94 2.56 3.70 3.86 5.7 (151) (65) (94) (98) (2.6) PS-12120 12 600 5.94 3.86 3.70 3.86 8.8 (151) (98) (94) (98) (4.0) PS-12180 18 875 7.13 2.99 6.57 6.57 12.8 (181) (76) (167) (167) (5.8) PS-12260 26 1300 6.89 6.54 4.92 4.92 18.7 (175) (166) (125) (125) (8.5) PS-12550 55 3000 10.25 6.60 8.20 9.45 39.7 (260) (168) (208) (240) (18.0) Note: Individual batteries have a nominal voltage 0112 volts. Ordering Information Part No. Model No. Description Shipping Weight lb (kg) 417692 PS-1270 PS Battery Pack, 12 (5.4) 7.0 AH, 24 VDC 437022 PS-1270 PS Battery Pack, 12 (5.4) 7.0 AH, 24 VDC (ULC) 417693 PS-12120 PS Battery Pack, 18 (8.2) 12 AH, 24 VDC BAT-1 2120-BP PS Battery Pack, 18 (8.2) 12 AH, 24VDC (4-Pack) (ULC) PS-12180 PS Battery Pack, 18 AH, 24 VDC PS-12180 PS Battery Pack, 18 AH, 24 VDC (ULC) BAT-12260 BAT Battery Pack, 26 AH, 24VDC PS-1 2550 PS Battery Pack, 55 AH, 24 VDC 439042 417694 26 (11.8) 437090 26 (11.8) 417695 40 (18.1) 417997 (38.1) TYCO FIRE PROTECTION PRODUCTS Copyright 2011 Tyco Fire Protection Products ONE STANTON STREET All rights reserved. MARINEIFE. WI 54143-2542 715-735-7411 Form No. T-2007144-3 Detection and Control Components Ji!WLtt I flo Pulse i New Series Photoelectric and Photoelectric! 144 Thermal Smoke Detectors (542R1542D) Features Plug-in detector line - mounting base included. Large wire-entry port. In-line terminals with SEMS screws. Mounts to octagonal and single-gang backboxes, 4 in. (102 mm) square backboxes, or directly to ceiling. Stop-Drop 'N Lock T1 attachment to base. Removable detector cover and chamber for easy cleaning. Built-in remote maintenance signaling. Drift compensation and smoothing algorithms. Simplified sensitivity measurement. Wide-angle, dual-color LED indication. Loop testing via "EZ Walk" feature. Built-in test switch. Description New Series photoelectric and photoelectric/ thermal smoke detectors represent a significant advancement in conventional detection, Incorporating three key features: installation ease, intelligence, and instant inspection. Installation ease: The New Series redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire-entry port and in-line terminals provide ample room for neatly routing the wiring inside the base The base accommodates a variety of backbox mounting methods, as well as direct mounting with drywall anchors. To complete the installation, New Series heads plug into the base with a simple Stop-Drop 'N Lock action. Intelligence: New Series detectors offer a number of intelli- gent features to simplify testing and maintenance. Drift compensation and smoothing algorithms, to minimize nuisance alarms, are standard in the New Series. When connected to an AUTOPULSE 542R/542D Control Panel, two-wire New Series detectors are capable of generating a remote maintenance signal when they need cleaning. This signal is indicated by LEDs located at the AUTOPULSE 542R/542D Control Panel. Instant inspection: The New Series provides wide-angle red and green LED indicators for instant inspection of detector condition. The LEDs indicate: normal standby, out-of-sensitiv- ity, alarm, or freeze trouble conditions. The "EZ Walk" loop test feature is available on two-wire New Series detectors When connected to an AUTOPULSE 542R/542D Control Panel. The "EZ Walk" feature verifies the initiating loop wiring by provid- ing LED status indication at each detector. 003037 Physical Specifications Operating Temperature Range: For models 2W-B and 4WB: 32°F to 120 °F (0 °C to 49 °C); for thermal models 2WT-B and 4W1-B: 32 OF to 100 OF (0 "0 to 38 °C). Storage Temperature Range: —4 OF to +158 OF (-20 °C to +70 °C). Operating Humidity Range: 10% - 95% RH, non-condens- ing. Thermal Sensor: 135 OF (57 °C) fixed (models 2WT-B, 4WT-B). Freeze Trouble: 41 OF (5 °C) (models 2WT-B and 4WT-B). Sensitivity: 2.50/o/ft (0.7620/o`/meter) nominal. Input Terminals: Utilize 14 to 22 AWG wire. Dimensions (including base): 5.3 in. (135 mm) diameter, 2.0 in. (51 mm) high. Weight: 6.3 oz (178.6 grams). Mounting Options: 3.5 in. (89 mm) octagonal backbox; 4 in. (102 mm) octagonal backbox; single-gang backbox; 4 in. (102 mm) square backbox with a plaster ring; or direct mount to ceiling. 3-54 Electrical Specifications Operating Voltage: 12/24 V non-polarized nominal; 8.5 V minimum; 35 V maximum. Maximum Ripple Voltage: 30% of nominal (peak to peak). Standby Current: 50 pA maximum average. Peak standby current: for two-wire models: 100 pA; not applicable for four- wire models. Maximum Start-Up Capacitance: For two-wire models: 0.1 pF; not applicable for four-wire models. Latching Alarm: Reset by momentary power interruption. Maximum Initial Start-Up Time: For two-wire models: 45 seconds; for four-wire models: 15 seconds. Maximum Alarm Current: For two-wire models: 130 mA limited by control panel; For four-wire models: 20 mA @ 12 V, 23 mA @24 V. Alarm Contact Ratings: For four-wire models: 0.5 A @ 30 VACNDC; not applicable for two-wire models. Alarm Reset Voltage: 2.5 V. Alarm Reset Time: 0.3 seconds. Wiring Diagrams 2-WIRE ZONE 1 WEi I •i3 I I I ++i 2-WIRE I CONTROL I \ PANEL 2W-B or2WT-B 2W-B or2WT-8 DETECTOR DETECTOR -,- ililiL MEN ( \ f I ++ 1 I ++IZC) 4-WIRE 68 /20200 CONTROL I \ PANEL 4W-B or4WT-B 4W-B or4WT-B DETECTOR DETECTOR 008055 LED Modes Green LED Red LED Power Up Blink every Blink every 10 seconds 10 seconds Normal (Standby) Blink every OFF 5 seconds Out of Sensitivity OFF Blink every 5 seconds Freeze Trouble OFF Blink every 10 seconds Alarm OFF Solid ON Power Up Sequence for LED Indication Condition Duration Initial LED 80 Seconds Status Indication Initial LED 4 Minutes Status Indication (if excessive electrical noise is present) Agency Listings and Approvals UL Listed ........................S911 FM .........................Approved CSFM . . . . . . . . . . . . . . . . . . . . 7272-1653:152 MEA . . . . . . . . . . . . . . . . . . . . . . . . 290-01 -E Maryland State Fire Marshal ........Permit No. 2093 ETL ........................Approved USCG .....................161.002/A42/1 Ordering Information Shipping Weight Part No. Description lb (kg) 435893 2W-B: Two-Wire 1.5 (0.7) Photoelectric Smoke Detector 435894 2WT-B: Two-Wire 1.5 (0.7) Photoelectric Smoke Detector with 135 OF (57 °C) Fixed Thermal Sensor 435895 4W-B: Four-Wire 1.5 (0.7) Photoelectric Smoke Detector 435896 4WT-B: Four-Wire 1.5 (0.7) PhotoClectric Smoke Detector with 135 OF (57 °C) Fixed Thermal Sensor Stop-Drop 'N Lock" is a trademark of Honeywell International Inc. TYCO FIRE PROTECTION PRODUCTS Copyright © 2011 Tyco Fire Protection Products ONE STANTON STREET All rights reserved. MARINErTE, Wi 54143-2542 715-735-7411 Form No. T-2008081-3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-13 photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not Intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 0 This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/Or other data but does not make an independent verification of any claims. This listing Is not M. an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division L.J L, I wo m' ii (D)J Listings and Approvals UL...........................S692 FM .........................Approved California State Fire Marshall (CSFM). . . . 7150-0028:199 Ordering Information Shipping (140 mm) Weight Part No. Description lb (kg) 435471 NBG-1 2LR Dual-Action Agent 2 (0.91) Release Station 418990 SB-10 Surface BackBox 0.5 (0.23) 41/8 IN. ------------(105 mm) ME o -J 0 SB-1O o c o 13/8 IN. (35 mm) DEEP Detection and Control Components qopu-ISO) NBG-12LR Dual-Action Agent Release Station (10-318, I0-636X-21 542R, 542D) General The NBG-1 2LR is an Agent Release Station designed for use with AUTOPULSE Fire Suppression Control Panels. Features Non-coded, dual-action operation Made with durable polycarbonate Optional surface backbox Dual-action release only Applications The NBG-12LR is ideal for areas such as clean rooms and computer rooms where a chemical agent is used to extinguish afire. Wiring TO MANUAL RELEASE (+) 2 CIRCUIT OR ADDRESSABLE * MONITOR MODULE REFER TO CONTROL PANEL MANUAL FOR LISTED ELR Dimensions, Backboxes for NBG-12LR 3-13.1 TYCO ARE PROTECTION PRODUCTS Copyright 02011 Tyco Fire Protection Products ONE STANTON STREET All rights reserved. MARINEflt, Wi 541432542 715-735-7411 Form No. T-2008057-3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of I CATEGORY: 7150- FIRE ALARM PULL BOXES LISTEE: NotifierOrie Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-12LRA, NBG-12LAO, NBG-I2LAOB, NBG-12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-1 2L, NBG-1 2LX, NBG-1 2LA, NBG-1 2PS, NBG-1 2LSP, NBG-1 2LPS, NBG-1 2LPSP, NBG-I2SP, NOT-BGI2LX, NBG-I2LXSP, NBG-I2LXBL and NBG-I2LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-I2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-I2LWP, NBG-12LAO, NBG-12L0, NBG-1 2LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. "4 *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant.. CSFM •Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, Installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Detection and Control Components LA um u Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Abort Switch is used to momentarily interrupt the release circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- sion system will not release. (Note: When the control unit is programmed for lRl compliance, the abort will not be effec- tive after pre-discharge.) When the pushbutton is released, the release circuit is activated (unless the control unit has been reset to the non-alarm condition). Description The Abort Switch assembly consists of a momentary- contact pushbutton switch, normally-open contact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed (S3623) when installed In the surface- mount box (with gasket) that is provided with the surface- mount assembly. Abort Switch (IQ-318, IQ-636X-21 542R9 542D) ABORT SWITCH (PARALLEL) EOL RESISTOR }-0 (+) I CONTROL UNIT I A I ABORT CIRCUIT ...Ø (—)TERMINALS OR ADDRESSABLE N.O. ABORT I MONITOR MODULE SWITCH L.....___ SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REOUIREMENTS. Ordering Information Shipping Weight Part No. Description lb (kg) 76494 Abort Switch, Surface-Mount 76495 Abort Switch, Flush-Mount 436983 Extra Contact Block, NC 436982 Extra Contact Block, NO 1.0 (0.45) 1-0 (0.45) 0.25 (0.11) 0.25 (0.11) MOUNTING DIMENSIONS 2 718 IN. (73 mm) 0 FIRE SUPPRESSION SYSTEM ABORT O 45/BIN. (117 mm) PUSH AND HOLD 0 TYCO ARE PROTECTION PRODUCTS ONE STANTON STREET MARINEflE A/1 54143-2542 715-735-7411 SURFACE-MOUNT FLUSH-MOUNT 3IN. - ----- _ 25 /BIN. (76 mm) (67 mm) Li 007362 3-15 Copyright © 2011 Tyco Fire Protection Products All rights reserved. Form No. T-2007130-3 411/16 IN. (119 mm) 0 0 NORMAl. DISCONNECT 0 FIRE SUPPRESSION SYSTEM DISCONNECT 0 0 4 5(8 IN, (117 mm) FLUSH-MOUNT L 2 518 IN. (67 mm) SURFACE-MOUNT Detection and Control Components ut?ri Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the "lock-our mode to serve as a reminder that the release cir- cuit has been disconnected. Description The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assem- blies include a double-gang weather-proof box and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed when installed in the surface-mount box (with gasket) that is provided with the surface-mount assembly. Key Maintenance Switch (IQ-3189 IQ-636X-2, 542R, 542D) TYPICAL WIRING DIAGRAM CONTROL urr RELEASE KEY-OPERATED CIRCUIT TERMINALS OR LOCK-OUT SWITCH ADDRESSABLE RELEASE 24 VDC CONTROL Ii, I I NC.1 MODULE' ACTUATOR I I N.C. I () [1LA11Y IS SHOWN - J 24 C POWERCONDITION IN ALARM I- SOURCE 007380 - - 24 VDC INDICATOR LAMP SEE CONTROL UNIT MANUAL FOR SPECIFIC WRING REQUIREMENTS. Ordering information Shipping Weight Part No. Description lb (kg) 76498 Maintenance Switch, Surface-Mount 2.0 (0.9) 76499 Maintenance Switch, Flush-Mount 2.0 (0.9) 436983 Extra Contact Block, N.C. 0.25 (0.11) 436982 Extra Contact Block, N.O. 0.25 (0.11) 436088 Spare Key 0.25 (0.11) MOUNTING DIMENSIONS m7381 3-16 TYCO FIRE PROTECTION PRODUCTS Copyright 5 2011 Tyco Fire Protection Products ONE STANTON STREET AU rights reserved. MARINE'flE. WI 54143-2542 715.735-7411 Form No. T-2007129-3 Detection and Control Components E©PuIsej Electronic Sounder with Strobe (IQ-318; IQ-636X-2, 542R, 542D, Z-10) Features Approvals include: UL, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) (Pending for MTWP) ADA/NFPA/UFC/ANSI compliant Meets OSHA 29 Part 1910.165 Strobes produce one flash per second over the regulated voltage range (MTWP produces 30-62 flashes per minute) Synchronize with Wheelock SM One-alarm appliance with eight selectable signals Two installer-selectable sound output levels cover range of 76-94 dBA reverberant Fast installation with IN/OUT screw terminals using #12 to #18AWG wire Available as FIRE or AGENT units The strobe complies with the Americans with Disabilities Act (ADA) and the demanding requirements of the UL 1971 Standard for the Hearing Impaired. The MT-24MCW 15, 30, 75, or 110 multi-candela strobe meets the light intensity requirements for the space being protected. One of eight different warning tones can be selected during installation by arranging four programming switches. This provides for superior sound penetration for various ambient and wall conditions with two field selectable sound output lev- els. The MT model mounts directly to a 4 in. (102 mm) square back box with an optional SFP semi-flush plate. The MTWP model mounts to a 5.25 in. (133 mm) square lOB weatherproof back box. Screw terminations provide secure attachment for field wiring of up to 12 AWG wire size. Technical Information Input Terminals .........................l8to 12AWG Size.....................5.125 in. x 5.125 in. x 4.375 in. (130 mm x 130 mm x 111 mm) Weight ................................0.9 lb (0.4 kg) Color.........................................Red Operating Temperature: MT Models.............32 OF to 120 OF (0 °C to 49 °C) MTWP Model........-31 OF to 150 OF (-35 °C to 66 °C) Mounting: MT Surface ...................... 4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box MT Semi-flush ...................4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box with SFP mounting plate (ordered separately) MTWP Weather-Proof ........5.25 in. x 5.25 in. x 2.625 in. (133 mm x 133 mm x 67 mm) weatherproof lOB back box (ordered separately) Voltage Range. ............ . .............. 16-33 VDC Input Voltage ................................24 VDC DIMENSIONS __ JI jIIliIIlIIIl1 ' iJJJllkllDhl°°©Ilij TO r -] MOUNTING WITH OPTIONAL SEMI-FLUSH PLATE SFP SEMI- FLUSH PLATE ELECTRONIC SOUNDE WITH STROBE 006145 TONE SELECTION SWITCHES MMING 3-8 Description The electronic sounder with strobe provides either indepen- 5 /8 IN. dent or simultaneous audible and visual alarm indication. The mm) electronic sounder is UL listed for primary or secondary sig- naling and the strobe is suitable for primary signaling in pub- lic mode for life safety applications. STANDARD BACK BOX Technical Information (Continued) TABLE 1: dBAAND CURRENT RATINGS FOR MULTITONE AUDIBLE PORTION RMS Current (amps) dBA @ 10 ft dBA © 10 ft (UL Reverberant) (Anechoic) 24 VDC 24 VDC 24 VDC Hi Output © 24 UL VDC max* STD Output @ 24 UL VDC max* Hi Output STD Output Hi Output STD Output Horn 0.074 0.108 0.033 0.044 92 87 99 93 Bell 0.040 0.053 0.018 0.024 86 80 92 87 March Time Horn 0.067 0.104 0.033 0.038 89 84 99 93 Code-3 Horn 0.069 0.091 0.026 0.035 88 83 99 93 Code-3 Tone 0.061 0.075 0.026 0.035 85 80 95 90 Slow Whoop 0.069 0.098 0.028 0.037 90 89 98 93 Siren 0.080 0.104 1 0.027 0.036 89 84 98 93 HI/LO 0.044 0.057 1 0.020 0.026 86 81 93 88 Note: U me strobe and auaIDle operate on me same circuit, aocl me strobe current trom laDle 2 to me auaible current trom laflle 1. RMS current ratings are per UL average RMS method. UL max current rating Is the maximum AMS current Within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (iSv for 24v units) For audibles the max current Is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. TABLE 2: CURRENT RATINGS FOR STROBE RMS Current (amps) Model MTWP-2475 MT-24MCW Candela 180cd 15cd 30cd 75cd llocd @ 24VDC 0.094 0.041 0.063 0.109 0.140 UL max* 0.138 0.060 0.092 0.165 0.220 WIRING DIAGRAM + FROM PRECEDING TO NEXT APPLIANCE OR RED APPLIANCE FACP OREOLR a a BLACK + -1 01+-1 M160 STROBE AUDIBLE Alarm Tones Tone Alarm Tones Pattern Description Horn Broadband Horn (Continuous) Bell 1560 Hz Modulated (0.07 sec ON/Repeat) March Time Horn Horn (0.25 sec ON/0.25 sec OFF! Repeat) Code-3 Horn Horn (ANSI S3.41 Temporal Pattern) Code-3 Tone 500 Hz (ANSI 53.41 Temporal Pattern) Slow Whoop 500-1200 Hz Sweep (4.0 sec ON/ 0.5 sec OFF/Repeat) Siren 600-1200 Hz Sweep (1.0 sec ON/Repeat) HI/LO 1000/800 Hz (0.25 sec ON/Alternate) Listings and Approvals* UL..........................................E5946 Factory Mutual .............................Approved California State Fire Marshal (CSFM) MT Models..........................7125-0785:155 M1WP Models.......................7135-0785:156 MEA...................................... 151 -92-E tJstings and Approvals are under Wheelock Inc. Ordering Information Part No. Model Description Shipping Weight lb (kg) 433356 MT-24MCW-FR Strobe, Multi- 2 (0.9) Candela w/Sounder (FIRE) 433357 MT-24MCW-AR Strobe, Multi- 2 (0.9) Candela w/Sounder (AGENT) 431526 MTWP-2475W-FR Sounderl75cd*, 2 (0.9) Weatherproof w/Sounder (FIRE) 437034 MTWP-2475W-FR Sounder/75cd*, 2 (0.9) Weatherproof w/Sounder (ULC) 429701 SFP Semi-Flush Plate 0.5 (0.2) 429700 lOB Surface Back Box 2 (0.9) 437035 lOB-R Surface Back Box 2 (0.9) (ULC) 439041 ISP2-R Adapter 0.5 (0.2) Rated 75cd at -31 ¶ (-35 °C). Rated 180 Cd at 77 °F (25 C). 1'tta FIRE PROTECTION PRODUCTS ONE STANTON STRT MARINEflE.W1 54143-2542 715-735-7411 Copyright 0 2011 Tyco Fire Protection Products All rights reserved. Form No. T-2007136-3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:0156 Page 1 of I CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models MTWP Multitone audible/visual signal device. Unit may be followed by 24 indicating voltage, 75 indicating candela rating, followed by W for wall mount, or C for ceiling mount, followed by two alpha characters indicating lettering and color. The WP in model designation indicates weatherproof. This series can provide one of eight tone outputs. Refer to listee's data sheet for additional detailed product description and operational considerations. *Models MTWP-24MCWH (wall mount) and MTWP-24MCCH (ceiling mount) audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. RATING: Electrical: 16-33 VDC Flash Rate: 60 flashes/mm *Candela: MTWP: 11 5c at -40 C MCWH: 56177cd at -40 C MCCH: 47173CD at -40 C INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and In a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical, audibility, candela rating and UL label. APPROVAL: Listed as audible/visual signal devices for indoor or outdoor use with separately listed compatible fire alarm control units. For synchronized strobes, Models SM-12/24, SMX-12/24 Sync Modules, DSM-12124 or DSMX-12/24 Duel Sync Modules (CSFM Listing NO. 7300-0785:132) must be used. These units can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. *Rev. 09-06-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 041, an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Detection and Control Components 14 1.4 se J4,, Features Approvals include: UL, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual (FM), and Chicago (BFP) (Pending for RSSWP) ADA/NFPA/UFC/ANSI compliant Meets OSHA 29 Part 1910.165 Low current draw with temperature compensation to reduce power consumption and wiring costs 24 VDC model with wide new UL 'Regulated Voltage' using filtered (DC) or unfiltered VRMS input voltage Strobes produce one flash per second over the regulated voltage range (RSSWP produces 30-62 flashes per minute) Wall Mount Synchronize with Wheelock SM ZERO Inrush above Peak Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire Available as FIRE or AGENT units Description The strobe is suitable for primary signaling in public mode for life safety applications and complies with the Americans with Disabilities Act (ADA) and the demanding requirements of the UL 1971 Standard for the Hearing Impaired. The RSS-24MCW 15, 30, 75 or 110 multi-candela strobe meets the light intensity requirements for the space being protected. The RSS strobe is wall mounted only to a 4 in. (102 mm) square electrical back box. Semi-flush mounting is available with the addition of an SFP mounting plate. The weatherproof RSSWP strobe is wall mounted only to a 5-3/16 In. (132 mm) square WPSBB-R weatherproof back box. The unique lens/reflector design of the RSS strobe maintains a consistent light dispersement pattern at 15 or 75 candela (Cd) light intensities while flashing at the ADA minimum of 1 flash per second. The 75 cd RSSWP model produces 30 to 62 flashes per minute over the regulated voltage range. Screw terminations provide secure attachment for field wiring of up to 12 AWG wire size. Technical Information Input Terminals .........................18 to 12 AWG Size ...................... 43/4 in. x43/4 in. x23/4in. (102 mm x 102 mm x 76 mm) Weight ................................0.9 lb (0.4 kg) Color.........................................Red Operating Temperature: RSS Models ............ 32°F to 120°F (0 °C to 49 °C) RSSWP Models.......-31 OF to 150°F (-35°C to 66°C) Strobe Multi Candela (10-31181 10-636X-2, 542R3 542D9 Z-10) Mounting: RSS Surface 4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box (2.5 in. (64 mm) recommended) RSS Semi-flush: 4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box (2.5 in. (64 mm) recommended) with mounting plate (order separately) RSSWP 5-3/16 in. x 5-3/16 in. x 1-11/16 in. Weatherproof: (132 mm x 132 mm x 43 mm) weatherproof back box (order separately) Voltage Range ........................... 16 —33 VDC Input Voltage ................................24 VDC RSS Strobe Candela (cd) .................. 15/30/75/110 RSSWP Strobe Candela (ccl) .......................75 STROBE WITH DIMENSIONS 4314 I FIRE - 0 IIr1v0yyI-o iiIE. FIRE - 0016S MOUNTING WITH OPTIONAL SEMI-FLUSH PLATE STANDARD BACK BOX 0 SFP MOUNTING PLATE SIGNAL STROBE 005145 0 3-6 WIRING DIAGRAM FROM + PRECEOIN - APPLIANCE OR FACP STROBE CANDELA SELECTION - BACK VIEW 006170 Average RMS Current* RSSIRSSP 24VDC Models 241575W 1575cd RSS/RSSP - Wall Mount 24MCW 15cd 30cd 75cd 110 Cd 24MCWH 135cd 185cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 Candela Ratings Series UL 1971 UL 1638 @ 77 °F (25 °C) UL 1638 @ -40 °F (-40 °C) RSS, MTWP UL Max Current (Strobe Only) 2475 30** 180 115 0.138 "Wall mount rating only RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16.33v for 24v units). For strobes, the UL max current is usually at the minimum listed voltage (16v for 24v units), For audlbles, the max current Is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see instal- lation Instructions. Listings and Approvals* + TO NEXT UL APPLIANCE RSS Models ............................. .... S5391 - OREOLA RSSWP Models..............................S3078 Factory Mutual (FM)..........................Approved California State Fire Marshal (CSFM) ASS Models .......................... 7125-0785:141 RSSWP Models ......................7300-0785:154 MEA ...................................... 151 -92-E Listings and Approvals are under Wheelock Inc. Ordering Information Shipping Part No. Model Description Weight lb (kg) 429698 RSS-24MCW-FR Strobe, Multi- 2.0 (0.9) DELA Candela (FIRE) CTOR 437030 RSS-24MCW-FR Strobe, Multi- 2.0 (0.9) Candela (ULC) 433352 RSS-24MCW-AR Strobe, Multi- 2.0 (0.9) Candela (AGENT) 433353 RSSWP-2475-FR Strobe, 75cd 2.0 (0.9) Weatherproof (FIRE) 433354 RSSWP-2475W-AR Strobe, 75cd 2.0 (0.9) Weatherproof (AGENT) 433355 WPSBB-R Back Box, 0.5 (0.2) Weatherproof 433358 SHBB-R Back Box, 0.5 (0.2) Shallow 437031 SHBB-R Back Box, 0.5 (0.2) Shallow (ULC) 429701 SFP Semi-flush Plate, 0.5 (0.2) Composite 439041 1SP2-R Adapter 0.5 (0.2) 429699 SM-i 2/24-A Sync Module 2.0 (0.9) lt'(X) FIRE PROTECTION PRODUCTS Copyright ©2011 Tyco Fire Protection Products ONE STANTON STREET All rights reserved. MARINETIE, WI 54143-2542 715-735-7411 Form No. T-2007133-3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0141 Page 1 of 2 CATEGORY: 7125 FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperiridusfries.com DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-#41C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 4110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP-24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRS..MCW *ZRSMCCH and *ZRS..MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33V0C/FWR Candela 15=5cd,1575=15/75cd on axis,30=30cd,75=75cd, 110=ll0cd(Wall) RSS24MCW,RSSP24MCW,*ZRS.MCW:Selectable15cd,30cd,75cd orllOcd RSS24MCC,RSS24MCCR,RSSP24MCC,*ZRSMCC:Selectable 15cd,30cd,75cd and 95cd RSS24MCWH,RSS24MCWHR,RSSP24MCWH,*ZRSMCWH:Selectable 135cd, 1 85c RSS24MCCH,RSS24MCCHR,RSSP24MCCH,*ZRSMCCH:SeIectabIe 115cd,177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed FIt the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation Instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0141 Page 2 of 2 SM-12/24, SMX-12/24, DSM-12124 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ANSUL® System Components UL EX-4510 2-1-12 Page 1-1.1 REV.5 II:1A;t.m. CV-98 Valve/Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN® agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft (6.1 m) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300; Meets TC3AM 176 or T03AAM176 Valve Brass Safety Relief Valve Brass Valve/Cylinder UL Listed (EX-4510); Assembly Listed for use with FM Approved systems Shipping Cap Steel Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft3 (m3) ff3 m3 lb (kg) in. (mm) in. (mm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (1339) 8.5 (216) 426148 250 (7.1) 266 (7.5) 169 (77) .57.7 (1466) 9.3 (236) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (1516) 10.7 (272) 426620 (LC) 350 (9.9) 355 (10.1) 217 (98) 60.2 (1529) 10.5 (268) 428646 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (1699) 11.0 (279) 426150* (LC) 1 435 (12.3) 439 (12.4) 260 (117.9) 1 66.9 (1699) 1 11.0 (279) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (1339) 8.5 (216) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (1466) 9.3 (236) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (1516) 10.7 (272) 426621 (LC) 350 (9.9) 355 (10.1) 217 (98) 60.2 (1529) 10.5 (268) 426259 (LC) 435 (12.3) 439 (12.4) 1 260 (117.9) 1 66.9 (1699) 11.0 (279) * Note 1: For Shanghai version, order Part No. 430935. Note 2: For Shanghai version requiring 172-bar cylinder (rating on cylinder not actual pressure in cylinder), order Part No. 437299. CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD—-- VALVE TAG HEIGHT TO OUTLET CENTER A 002251 CV 98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. Note: Use Flexible Discharge Bend (Part No. 427082) when attaching valve to supply pipe or manifold, 311 IN. PRESSURE (89 mm) GAUGE REFERENCE SAFETY RELIEF VALVE oossm two Fire Protection One Stanton Street +1-715-735-7411 Copyright S 2012 Tyco Fire Products LP. All rights reserved. Products Marinette, WI 54143-2542 www.ansul.com Form No. F.9877-05 ANSUL® System Components ULEX-4510 11-1-00 Page 1-3.7 1.01.IANSUL.1 ATyco/ntemgJww/Company HF Electric Actuator Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 7327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 OF to 130 OF (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage:................12 VDC @ 0.57 amps Rated Voltage: Minimum: ..............................12.0 VDC Maximum .............................14.0 VDC Thread Sizefrype. ............ 1/2 in. straight female for electrical conduit hookup Material: Body....................................Brass Plunger: ........................... Stainless Steel Listings and Approvals UL....................................... E91021 ULC........................................1165 FM .....................................2T8A9.AF 2 1/41 N. (57 mm) 001355 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MAtITNEITE, WI 54143-2542 715-735-7411 Form No. F-2001067 02001 Armul Incorporated ANSUL® 1.01.jmoup A Tyco IntematwiW Company Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. System Components ULEX-4510 11-1-00 Page 1-3.6 Booster Actuator The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 11/4-18 UNEF 11/8-18 UNEF X6037 ANSUL and INERGEN are trademarks of Ansul Incorporated or Its affiliates. TYCO SAFETY PRODUCTS, MAINETTE, WI 54143-2542 715-735-7411 Form No. F-2001066 02001 Ansut Incorporated r1i 0T1!iU Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote manual pull station, the pull station must contain the com- ponents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. Four actuators are available. Each is designed for a specific component. * Add 1 9/16 In. (3.9 cm) to height when lever is in the straight up position. System Components UL EX-4510 2-1-12 Page 1-4.1 REV. 5 Lever Release Actuator Component Material Approvals All Manual Brass with UL Listed (EX-4510); Cable-pull Stainless Listed for use with Actuators Steel Pin FM Approved systems Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the 1 in. and 2 in. selector valves. Mounts directly to pressure operated stackable actuator for 1 in. and 2 in. selector valves. Actuator has the handle painted red. tqco Fire Protection One Stanton Street i-1-715-735-7411 Copyright 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansul.com All tights reserved. Form No. F-9879-05 * DIRECTI OF FLOV VISIBLE ORIFICE IDENTIFICATION 002197 ANSUL System Components UL EX-4510 2-1-12 Page 1-15 REV. 8 Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in,, 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 Cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in NPT pressure reducer/union 294 in (75 cm) 204 in (5.2 cm) 331 in (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer/ Body: Forged 1/2, 3/4, 1, UL Listed (EX-4&10); Union Steel 1 1/4, 1 1/2, Listed for use with FM Approved systems 2 in. NPT Orifice Plate: Stainless Steel Note: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. 'Orifice diameter must be specified when placing order. tqco Fire Protection One Stanton Street +1-715-735-7411 CopyrIght 5 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansuI.com All rights reserved. Form No. F-9311-10 System Components UL EX-4510 11-1-00 Page 1-16.1 REV. 2 ceaçJ 1800 Discharge Nozzle Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 1800 nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8, 1/2,3/4, 1, 1 1/4,1 1/2, 2 21/2,3 NPT Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle Size A-in. B-In. C-In. 1/4 in. 5/8 19/16 21/32 3/8 in. 3/4 15/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 11/8 25/32 7/8 1 in. 113/32 29/16 1 11/4in. 13/4 23/4 11/16 11/2 in. 2 231/32 1 1/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 1 1/4 NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. i - 2743 * Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Ansul Incorporated or Its affiliates. TYCO SAFETY PRODUCTS, M4JRINETIE, WI 54143-2542 715.735.7411 Form No. F-99020-1 @2001 Ansul incorporated ANSUL® rrn Clean .4 Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing com- ponents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coat- ing. Uprights and back frame assemblies can be bolted or System Components UL EX-4510 2-1-12 Page 1-17 REV. 9 Cylinder Bracketing welded together, which ever makes the installation more Convenient. Component Material Approvals Bracketing Steel UL Listed (EX-451 0); Listed for use with FM Approved systems Shipping Assembly Part No. Description 845120 200 0 (5.7 M3) cylinder strap (single cylinder) 845244 200 0 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 0 (7.1 m3) cylinder strap (single cylinder) 845261 250 0 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 0 (9.9 mS), 425 ft3 (12.0 m3), 435 ft3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft3 (9.9 m3), 425 ft3 (12.0 m3), 435 0 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft3 (12.0 mS) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 0 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 0 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 0 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 0 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft3 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 0 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 0 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row Multi-Cylinder Single Cylinder PUP RIGHT WEIGH RAIL SUPPORT / .1 / 'I I I #_J'I I I ii i I I II II I II BACK FRAME CYLINDERCLAMP II II CARRIAGE BOLT WITH NUT II CLAMP II I II II II I II II CHA RIGHT II I, I BRACKETFOOT I II II Ii I Ii II 1 Ii l I I tNNEL _j LEFT BRACKET FOOT 002200 tqco Fire Protection One Stanton Street i-i -715-735-7411 Copyright © 2012 Tyco Fire Products LP. All rights reserved. Products Marinette, WI 54143-2542 www.ansuI.com Form No. F-9309-09 ANSUL System Components UL EX-4510 2-1-12 Page 1-23 REV. 2 he Warning Plate — Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (.64 cm) UL Listed (EX-4510); Listed for use with FM Approved systems 12.00 WHEN ALARM SOUNDS VACATE AT ONCE INERGEN® AGENT BEING RELEASED V.Ineii@r Ct*aUINafl\\ , J S5fl?$ LABEL NO. 416265 002745 tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Products Marinette, WI 5414,3-2542 www.ansuI.com All rights reserved. Fore, No. F-9315-04 7.00 ANSUL® System Components UL EX-4510 2-1-12 Page 1-24 REV. 3 Warning Plate - Outside Room Without Alarm Description The warning plate is available for mounting outside the hazard area to warn the personnel that the space is pro- tected by an INERGEN® system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room 01 Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (56 cm) UL Listed (EX-4510); Listed for use with FM Approved systems U 8.00 WARNING THIS SPACE IS PROTECTED BY AN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. 7.00 DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. Ln%1WW 0 LABEL NO. 416266 002717 tqcci Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansuI.com All rights reserved. Form No. P.9314-OS kilAmsuLl A Tyco 1nzewa;ionlCompm' One Sanwn Sveez Mwinou& IM 54143-2542 VM'W.8fl6111. corn une DATE: June 8, 2012 TO: All Authorized ANSUL System Distributors FROM: Product Management — Engineered Systems SUBJECT: New Discharge Pressure Switch Introduction DESCRIPTION We are pleased to announce the new, improved Discharge Pressure Switch (Part No. 437900). The switch features a redesigned housing and face plate. The new housing provides two options for conduit Inlet sizes — the standard 314 in. and the new 1/2 in. size. The new face plate/plunger assembly design saves time during maintenance by allowing the switch to be tested without removing the cover. This feature also maintains the integrity of the switch by eliminating the exposure to environmental factors. The switch is three pole, double throw (3PDT) allowing for multiple connections and switching capabilities, and providing versatility and flexibility In the Installation process. Bulletin No. 5849 The pressure switch is operated by the system agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to shut down equipment (single or 3-phase), turn on lights or alarms, or provide pressure switch feedback to an AUTOPULSE control panel. The housing is constructed of 16 ga. steel, painted red, and is rated IP65 for dust and water ingress. The 3/8 In. NPT brass pressure inlet is used to connect the pressure switch to the suppression system. Minimum operating pressure is 50 psi (35 bar). Component Material Thread Sfze'Fype Electrical Rating Approvals Pressure Switch — Switch: Nickel-plated Conduit Inlets: 3/4 10A, 250 VAC UL Listed 3POT Brass in. and 1/2 in. 1 5A, 125 VAC Listed for use with Housing/Cover: C.R. Pressure Inlet: 318 3/4 HP, 250 VAC FM Approved 16 ga steel In. NPT Female systems Plunger: Stainless 1-, 2-, and 3-phase Steel Pressure Port: C37700 Brass UL EX-2968 (High Pressure CO2) UL EX-4510 (INERGEN, SAPPHIRE) Main Telephone Numbers 1.800-8626785 or I-715-735•7415 Customer Services: Press 2 Technical Services: Press I Training Services: Press 6 Quetily Assurance: Press 6 Literature Fax Orders; 1800.543.982 or 1-715-7323474 Bulletin No. 5849 June 8, 2012 Page 2 So CIL- ELECTRICAL SCHEMATIC "cv 1.1 008978 008979 INsTALLATIoMMIRINGrrEsTINGRESET AND RECHARGE Please see the attached instruction sheet for details. This bulletin is a supplement to the following ANSUL System Design, Installation, Operation and Maintenance Manuals: AQUASONIC (Engineered — Part No. 437205) dated March 1, 2010 AQUASONIC (Pre-Engineered — Part No. 435650-03) dated July 19, 2010 High Pressure CO2 (Part No. 427604-04) dated July 19, 2011 INERGEN 150-Bar (Part No. 416655-13) dated February 1, 2012 INERGEN 200-Bar (Part No. 430149-04) dated February 1, 2012 Low Pressure CO2 (Part No. 425908-01) dated February 1, 2010 SAPPHIRE (Part No. 570590-04) dated September 1, 2010 SAPPHIRE (India version — Part No. 570805) dated March, 2011 The information contained in this bulletin Will be added to the system manuals at the next issue date. Should you have questions regarding this bulletin, please contact Technical Services as noted below. UL EX-2968 (High Pressure CO2) UL EX-4510 (INERGEN, SAPPHIRE) Main Telephone Numbers: 1-800-862-6785 or 1-715-735-7415 Customer Services: Press 2 . Technical Services: Press 4 • Training Services: Press 6 . Quality Assurance: Press 8 Literature Fax Orders: 1-800-543-9822 or 1-715-732-3474 IN. nm) 314 IN. CONDU KNOCK FIGURE 1 CONIC two Fire Protection Products These Installation instructions are intended for use with the Discharge Pressure Switch (Part No. 437900). Personnel respon- sible for the system installation, recharge, or maintenance must read and fully understand these Instructions before attempting to Install or service any discharge pressure switch. The fire suppression system could actuate, Introducing a poten- tially hazardous environment, causing possible serious Injury or death if these instructions and precautions are not followed. Always read instructions and follow them carefully during Instal- latlon. DESCRIPTION The discharge pressure switch Is operated by agent pressure when the fire suppression system Is discharged. The three pole, double throw (3PDT) pressure switch can be used to open or close electrical circuits to shut down equipment (single or 3- phase), turn on lights or alarms, or provide pressure switch feed- back to an AUTOPULSE control panel. The pressure switch specifications are as follows: Body: Forged C37700 Brass Housing: C.R. Steel, painted red Pressure Connection: 3/8 In. NPT Female Actuation Pressure: Less than 50 psi (3.4 bar) Max. Working Pressure: 2900 psi (200.0 bar) Proof Pressure: 8333 psi (574.5 bar) Temperature Range: -4 OF to +130 OF (-20 °C to +54 °C) Dimensions: 4 1/2 in. (L) x 25/8 In. (W) x 41/2 in. (H) (114 mm (L) x 67 mm (W) x 114 mm (H)) Weight: 2.2 lb (1.0 kg) lPRating: IP65 Switch Configuration: 3PDT Electrical Ratings: iSA, 125 VAC bA, 250 VAC 3/4 HP, 250 VAC 1-, 2-, or 3-phase Electrical Connections: 1P2 In. and 3/4 In. Conduit Knockouts with #6-32 UNC Terminal Screws DISCHARGE PRESSURE SWITCH INSTALLATION INSTRUCTIONS 11-22-11 Page 1 1t2 IN. CONDUIT INSTALLATION Mounting the Enclosure The pressure switch enclosure is designed to be mounted on any suitable flat surface, near the agent storage tanks, using the two mounting tabs provided. Pressure Port Connection The switch is designed to be piped directly off the system discharge manifold (see Figure 2), which is the preferred method, or If the system is utilizing an AUTOMAN Il-C releasing device, the pressure switch can be piped off the actuation fine (see Figure 3). Piping requirements vary from system to system. Consult the system Installation manual for specific Installation piping require- ments for auxiliary pressure-operated devices. A 3/8 in. to 1/4 In. reducing bushing Is supplied with the pressure switch assembly to facilitate connection to 1/4 in. actuation hose. PRESSURE CONNECTION TO SYSTEM DISCHARGE MANIFOLD FIGURE 2 DISCHARGE PRESSURE SWITCH INSTALLATION INSTRUCTIONS Page 2 11-22-li Pressure Switch Feedback For system discharge feedback to p control panel, the switch should be Wired as shown In Figure 5. WIRING FOR PRESSURE SWITCH FEEDBACK I,. 1ESSURE vllc*I 1 -'4 TO CONTROL EOL RESISTOR PANEL 3 FIGURE 5 Upon system actuation, the normally-closed (N.C.) contacts OPBfl up and the nonnauy'open (N.O.) contacts close, bypassing the End-01-Line (EOL) resistor and signaling the panel that a discharge has occurred. Consult the specif Ia control panel Installation and operation manual for proper EOL resistor value, Direct Equipment Shutdown/Activation A WARNING FIGURE 3 WIRING INSTALLATION (Conhinued) PRESSURE CONNECTION TO AN AUTOMAN Il-C RELEASE Exeedinp the switches listed electrical ratings can damage the switch, creating a potentially hazardous situation that may cause serious Injuiy or death Care should be taken to ensure listed ratings are not exceeded To ensure the pressure switch maintains Its listed IP rating, proper conduit seals must be used when connecting the conduit system to the pressure switch enclosure Failure to do so may m result in preature pressure switch failure, resulting in a polOri lially hazardous; condition that may cause serious injury or death. NOTICE Power-limited and non-power-limited circuits should not be wired in the some pressure switch. Separate switches should be used If switching of both types of circuits is desired. The pressure switch can be wired to provide system discharge feedback to an AUTOF(JLSE control panel, or to directly switch equipment on or off upon system discharge. The contact arrange- ment of the switch is shown in Figure 4. Contacts are shown with the switch in the set" position. PRESSURE SWITCH 1 I I CONTACT ARRANGEMENT 1: Polo 1, Normally-Closed (NC,) 1Q Q Q 2; Polo 1. Common (COM,) 3 Pole 1, Normally-Open (NO,) 4: Pole 2, Ploima!IyCIosed (NC2) r 6 a 5: Polo 2. Common (COW) 6: Pole 2. Nommity•Opon IN02) 3 5 1: Polo 3, Nonnafly'Closod (NC3) 9; Polo S. Common (COM3) LL S Polo 3, NorrnalbjOpon(NO) PRESSURE INLET For direct equipment shutdown or activation, the switch should be wired as shown in Figures 6 and 7. WIRING FOR DIRECT EQUIPMENT SHUTDOWN TO POWER TO EQUIPMENT TO RE DE-ENERGIZED 2 FIGURE6 00002$ WIRING FOR DIRECT EQUIPMENT ACTI VATION TO 1OWM --A2 TO EQUIPMENT 3 TO BE ENERGIZED FIGURE 7 X,25 NOTICE A single pressure switch should not be used to switch circuits utilizing different voltages. If equipment utilizing different voltages Is being used, separate switches should be used for each voltage level. DISCHARGE PRESSURE SWITCH INSTALLATION INSTRUCTIONS 11-22-11 Page 3 WIRING (Continued) Ground-Fault Protection To properly ground the switch assembly, two green-colored ground screws are provided, one In the back box and one on the front cover (see Figure 8). Both should be bonded to earth, when required, to ensure the entire assembly Is protected against ground-fault short circuits. FUNCTIONAL TEST Ensure the suppression system is locked out when testing the discharge pressure switch. Failure to do so may result In intro- ducing a potentially hazardous environment causing serious Injury or death. i o The pressure switch plunger is designed so that, once Installed, 0 the switch cover does not have to be removed to test the switch's functionality. To test the switch, perform the following steps: EEC1RCAL *OW.1 Insert a flat-blade screwdriver or other Instrument into the : groove on the side of the plunger. Pull up on the plunger until an audible click is heard. The pressure switch c ontacts will transfer. Verttythe switch produced the desired system response. Depress the plunger, returning it to the set" position, to reset ro the switch contacts. / ° ° 1 RESET AND RECHARGE Cc825 GROUND To reset the pressure switch after a system discharge, perform SCREW the following steps: Remove the pressure from the actuation line of the pressure switch (If not already done). Depress the plunger on top of the switch until the top of the plunger Is flush with the top of the pressure port. An audible click should be heard. 0 0 ooa,ai ENCLOSURE GROUND SCREW (ABOVE) AND FRONT COVER GROUND SCREW (BELOW) FIGURE 8 tqca Fire Protection One Stanton Street +1-715-735-7411 copyright @2011 Fy00 Flie P,o!ecton Products AD rights reserved. Products Marinette, WI 54143-2542 www.ansuI.com Part No. 439090 ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved 1J.1.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 He: Data file name: C:\Program Files (x86)\INERGEN DESIGNER\Synteract RM117Jnr Job Number 7-89022-5 for SYNTERACT Address: 5909 SEA OTTER PLACE FILE ROOM 117 CARLSBAD CA 92010 Agent Storage Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 439 cubic feet of INERGEN stored in each of 2 cylinders. Total agent in storage is 878 cubic feet. Time to discharge 7 90 cubic feet (90% of INERGEN) is 80.1 seconds Maximum pressure downstream of manifold orifice is 1311 psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. SERVER ROOM 117 1539.0 45 878.0 44.1% at 80°F 42.9% at 60°F 34.2% at 60°F Sea level equivalent oxygen: 11.7% at 80°F Free Vent Calculation Peak Maximum Wall Minimum Free Area Rate Strength Vent Area SERVER ROOM 117 1632.4 cfm 5.0 lbs./sq.ft. 62 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee!. Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 40 1 0.0 38.0 0.0 MELD 1033 1009 425.1 2 3 3/4 801 1.0 . 1.0 1.0 MFLD 1009 1009 425.1 3 4 1 80T 1.0 1.0 0.0 MFLD 1009 1009 850.2 4 5 ORIFICE .257 INCHES DRILL NO. F 1009 424 850.2 5 6 1 401 11.0 18.9 5.0 424 579 850.2 6 301 1 40T 1.0 1.0 -1.0 579 579 850.2 1 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (JJ.I 2Y0A9.AF, (JLC listed CExIlSI Version 2.1.2 File: Data file name: C:\Program Files (x86)\1NERGEN DESIGNER\Synteract RMI I 7inr Job Number: 7-89022-5 Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions/ Eql Start End Pipe Size (ft) 90's Tee Tee Cplgs (ft) 1 2 1/2 401 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 3/4 801 1.0 0 0 0 0 3 4 1 80T 1.0 0 0 0 0 4 5 I 80 T 0 0 0 0 Man. Orifice 5 6 1 40T 11.0 3 0 0 0 6 301 1 40T 1.0 0 0 0 0 Nozzle Performance Summary Nozzle Nominal Drill Drill Quantity (Cu ft) Area Number Pipe Size Number Diameter Discharged Name 301 1 40 T U 0.368 878.0 SERVER ROOM 117 Wiessages/Errors ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 Calculation done on 8/4/2017 at 2:12:56 PM 'ipe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum ipe pressure for Grade A-5313, A-I 06B Seamless. To determine if other grades are acceptable, rerify that the maximum pipe pressures for other grades are equal to or greater than the maximum rnticipated downstream pressure. Calculation by HCl Systems, Inc. Ontario 91761 Telephone: 909-628-7773 Fax: 000-000-0000 2 End of Printout