Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5919 SEA OTTER PL; ; FPC2019-0083; Permit
PERMIT REPORT ('7city of Carlsbad • Ej3 1c Print Date: 10/24/2024 Permit No: FPC2019-0083 Job Address: 5919 SEA OTTER P1, CARLSBAD, CA 92010-6630 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 2090820900 Track U: Applied: 03/28/2019 Valuation: $1,316,23.00 Lot U: Issued: 04/09/2019 Occupancy Group: Project U: Finaled Close Out: 08/20/2019 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Fieri, Dominic Plan Check #: Wong, Cindy Salcedo, Felix Project Title: Description: DJO GLOBAL: - SPRINKLER 11(126 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC CRYSTAL LYONS 12316 OAK KNOLL RD, # STE A 12316 OAK KNOLL RD, U STE A POWAY, CA 92064-5364 POWAY, CA 92064-5363 (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $654.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carkbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov - oc3 MATERIAL CUT SHEETS DJO GLOBAL T.I. 5919 SEA OTTER PLACE CARLSBAD, CA 4 Page 1 of 6 N I I(II1c® MICROFAST QUICK III[U'1W.. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applicationswhere colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®os cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) °cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W(B with 21475M/B) Page 2 of 6 \J II(IItt,*IG® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 17.10.05 Rev 17.2 0. Page 3 of 6 N II(IFt*1c® MICROFAST® QUICK 4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' U Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for d pendent spri klers ** 1/2" ratchet (not available from Viking) . . Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W1B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 N II(II4n1c ® MICROFAST® QUICK 4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Te I The Viking Microfast Quick Response a - KEY Pendent vi- Spnnkler VK302 AiX+- Esctc apIcbH Maximum 175 PSI (12 Bar) WWP Base Thread Size Nominal Overall Listings and Approvals' Part SIN tSpr;;kler e ______ K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric' Inches mm cULus4 VdS LPCB (E 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2,C2X Al A1Z,B1Y D1Z,C1Y - - 19780 VK302 Pendent 1/2" - 5.6 80.6 2-1/4 58 -- -- - -- -- 03 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 - - - - - 03 NOTICE - Prodact Below -Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm F 5.6 80.6 2-1/4 58 AIZ, B1Y, 02, C2X -- -- - -- -- 18021 VK302 Pendent 1/2" 15 mm 1 5.6 1 80.6 2-1/4 58 AiX, B1Y Al AiX, B1Y Dix, dY8 Dlx, dY9 - Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 °F (57 °C), 155 °F (68 "C), 175 °F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 "C), 286 -F,,'141 °C) Polyester58, Black Polyes- Viking Micromatic Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter56 Y - Standard surface-mounted escutcheon or the (79 °C), and 200 °F (93 "C) 2 - ENT' Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 °F (68 °C), 175 °F (79 °C), and 3-Chrome mati& Model E-1, E-2, or E-3 Recessed Escutcheon 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the D - 155 °F (68 °C), 175 °F (79 °C), 200°F Viking Microfast Model F-i Adjustable Escutcheon (93 °C), 286 °F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 \J II(II1G ® MICROFAST® QUICK I:iir*1..7w RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) KEY The Viking Microfast° Quick Response Pendent Sprinkler VK302 A1X4- C ci Maximum 175 PSI (12 Bar) WtNP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number1 SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 1 15 m 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 '(.1110 __ I I/T2 Limited Availability (f fr1ct'Local Viking Offlpp) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 °F (57 °C), 155 °F (68 °C), 175°F (79 °C), 200 °F Viking Micromatic Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B- 135 -F (57 °C), 155°F (68 °C), 175°F (79 °C), and i - Brass,Chrome,White Polyester, Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfast Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 — Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 17.10.05 Rev 17.2 - 2-1/8" 51mmi + 1-314" (45 mm) Max. 1 2-1/8' (54 rnm)j.. ..y . 1-1/8" L (29 mm) 2" (29 mm) Mm. (51 mm) ., Mm. Max. - Ceiling Opening Size 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Page 6 of 6 MICROFAST® QUICK 4J II(II"lG RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2" ;•__• . 2-1/2" (64 mm) maximum (15 mm) NPT 2-1/8— (54 mm) 2-1/4" 11 1-3/4" 2' ) (38 mm) (57 mm) : (51 mm) .ç- j, Mm. 4, .: (45 mm) Max. y V Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon ft Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to ½" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS 0 4S cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 L VdS Approved: Certificate G4080021 . LPCB Approved: Ref. No. 096e/12 CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Form No. F_103005 18.04.12 Rev 18.1 Replaces Form No. F_103005 Rev 17.1 (added stainless steel cover plates) Page 2 of 7 MIRAGE® STANDARD AND uq..w'k QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C 11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 "C) = B, 175 "F (79 °C) = D, 200 "F (93 "C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5116" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 "F (57 "C) UL (139°F (59 °C) FM and LPCB) =A, 165 "F (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 "F (74 "C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 "F (57 °C) UL (139 "F (59 "C) FM and LPCB) =A, 165 °F (74 "C) = C For example, cover 21876 with a 165 "F (74 °C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.04.12 Rev 18.1 Page 3 of 7 ft MIRAGE® STANDARD AND \J I FJ ISIGI l:II[.Lu'JM QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE I: AVAILABLE SPRINKLERTEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Cover Plate Large Cover Square Cover Temperature Nominal Ambient Temperature Rating of Cover Base Part Plate Base Part Plate Base Part Bulb Color Classification Temperature Ceiling Assembly (Required) Number Number' Number' Rating' Temperature' 135 °F (57 °C) cULus Ordinary 155 °F (68° C) 100 °F (38 °C) 13504 or 21876 13642 or 21875 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175°F (79° C) 150°F (65° C) 165°F (74 °C) 13504 or 21876 13642 or 218751 15394 Yellow Intermediate 200°F (93° C) 150°F (65° C) 1 165°F (74 °C) 13504 or 21876 13642 or 2187551 15394 Green Cover Plate Finishes5: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. cus?b to (I— 0 0 NIKJNG All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers ,• 3-5I16° (84 mm) Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.04.12 Rev 18.1 Page 4 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'sj I 1(1 4 l:I1[•u1w' SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart I (UL) - Mirage' Concealed Pendent Sprinklers VK462 and VK463 AV1' Cy RI Ffrsh KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Inch mm U.S. metric' cULus' NYC VdS7 LPCB CE I (?) Base Part No.' Pressure Standard Response Applications 13503A VK462 1/2" 5.6 80.6 175 psi (12 bar) -- - AY1, CZ1 AY1, BZ1 AY1, CZ1' -- 19785A VK462 1/2" 5.6 80.6 175 psi (12 bar) -- - - - -- AY2, CZ2 21356A VK462 - 15 5.6 80.6 175 psi (12 bar) -- - - - -- AY2, CZ2 Quick Response Applications 13503A VK462 1/2° 15 5.6 80.6 175 psi (12 bar) AV1, BX1,AV1,BX16 - - - - AV1, BX1, 13503JN" VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX16 - - - - AS3, BT3 13667A VK463 1/2" 15 5.6 1 80.6 250 psi (17.2 bar)' AV1, BX1 AV1, BX1' -- -- - - Cover Plate Assembly Temperature Ratings', S - 135 OF (57 'C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes" Sprinkler Temperature Ratings T - 165 OF (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, A - 155 OF (68 'C) V - 135 OF (57 'C) cULus Listed cover 13504, 13642 (large diameter), Antique Brass, Brushed Brass, Brushed Copper, B - 175°F (79 'C) and 200°F (93 'C) or 15394 (square cover plate) Painted White, Painted Ivory, or Painted Black C - 200 OF (93 'C) X - 165 OF (74 'C) cover 13504, or 13642 (large diameter) 2 - Brass V - 135 OF (57 'C) cover 13504 LPCB Approved as 139 OF (59 'C) 3 - Stainless Steel Z - 165 OF (74 'C) cover 13504 Footnotes I Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 'Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 +A1:2001 +A.2:2004 +A3:2006, Certificate G4080021. 'CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 'The 135/139 OF cover has an orange label. The 165 OF (74 'C) cover has a white label. ° Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact 'liking for additional information. " cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.04.12 Rev 18.1 Page 5 of 7 MIRAGE® STANDARD AND \I I 1(1 t%IGI SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1 cULus Listing Reguirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Arrnroval Reouirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.04.12 Rev 18.1 Page 6 of ,7 R MIRAGE® STANDARD AND 'Si I FI Its1c!:i QR CONCEALED PENDENT SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) ' Tinwam~Rlx -11 . So Mirage" Standard Response Concealed Pendent Sprinkler VK462 AW1° Cr Pure Fn KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric' Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Ratings' .4 Cover Plate Assembly Finishes' Sprinkler Temperature Ratings Y- 139°F (59 °C) cover 21875 or 21876 Z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B - 175 °F (79 °C) and 200°F (93 °C) 15394 (square cover plate) Brushed Copper Painted White Painted X - 165 F (74 C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - _FM Also refer to Approval Chart 2 above.) Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F103005 18.04.12 Rev 18.1 2-1/16" (52 mm) Minimum 2-9/16' Ma 2-3/4" (70 mm) or 3-5/16" (84 mm) Page 7 of 7 MIRAGE® STANDARD AND NIKJv QR CONCEALED PENDENT u SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly - tj Protective cap Sprinkler Wrench removed -. Part No. 14047W/B** Use wrench - 14047 WIB** -4 Step 1: Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) I diameter opening required in the ceiling. Step 2 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. DO NOT overtighten. wrench Use only the designated sprinkler wrenches, Viking i i Sprinkler Part Numbers 14047W!B** or 14031**. A leak tight seal ..,lframe arms should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. - Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) 1/2" (15 mm) NPT IV J _ ,M) c ---- - NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.04.12 Rev 18.1 Replaces Form No. F_103005 Rev 17.1 (added stainless steel cover plates) Page 1 of 6 \J II(II%1G® MICROMATIC® STANDARD l:I1[.qiu,jAwA RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Micromatic Standard Response Upright VK100 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes and tem- perature ratings to meet design requirenents. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coat ngs as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on de uge systems. Refer to Ordering Instructions. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, 2017, 2043 AiWARNING: Cancer and Reproductive Harm- www.P65Wamings.ca.gov NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 ba)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar) Approvals ONLY is 5 psi (0.35 bar). The minimum operating pressure for LPCB and CE ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper U'JS-C 19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ttNot for FM Approval. Ordering Information: (Also refer to the Current Viking price list.) Order Micromatic® Standard Response Up-ight VK100 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-NV, ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C) = H, 500 °F (260 °C) = L. For example, sprinkler VK100 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12986A8 Available Finishes And Temperature Ratngs: Refer to Table 1. Form No. F_052014 18.10.11 Rev 17.1.P65 Replaces Form No. F_052014 Rev 17.1 (Added P65 Warning.) Page 2 of 6 MICROMATIC® STANDARD RESPONSE UPRIGHT \jII(IF41G® SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/8 (avai able since 2017). Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B (available since 2000) Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/13* (available since 2006) *A 1/2 ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standads. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® Standard Response Uright Sprinkler VK100 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's curren list price schedule or contact Viking directly. Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475M/B Coated Sprinklers 10896W113 Figure 1: Standard Sprinkler Wrenches Form No. F_052014 18.10.11 Rev 17.1.P65 Page 3 of 6 N II(IFt1G® MICROMATIC® STANDARD l:IIr.qi.,yw RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Mt 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient lb C or Classification Temperature Rating' Ceiling Temperature'0 Ordinary 135 'F (57 °C) 100 OF (38 °C) Orange Ordinary 155 'F (68 °C) 100 OF (38 °C) Red Intermediate 175 'F (79 °C) 150 OF (65 °C) Yellow Intermediate 200 'F (93 °C) 150 OF (65 °C) Green High 286 ¶ (141 °C) 225 OF (107 °C) Blue Extra High 360 ¶ (182 °C) 300 °F (149 °C) Mauve Ultra High' 500 "F (260 "C) 465 OF (240 "C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135 OF (57 "C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 OF (68 "C) Lt. Brown Wax 175 OF (79 "C) Brown Wax 200 OF (93 "C) Brown Wax 286°F (141 "C) Dk. Brown Wax' Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar erclosures with normal operating temperatures above 300 OF (149 "C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 "C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrcsion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to: installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with olyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Wax melting point is 170 OF (76 "C) for 286 OF (141 "C) tempeature rated sprinklers. Form No. F_052014 18.10.11 Rev 17.1.P65 Page 4 of 6 '.J 1 1(1 FIG® MICROMATIC® STANDARD lislIl[sflU.1f RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) -H KEY Micromatic Standard Response Upright Sprinkler VKIDU AX Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part SIN (Refer also to UL Design Criteria.) Number' NPT BSP U.S. I metric2 Inches mm cULus4 VdS LPCB CE Standard Orifice 12986 VK100 1/2" 15 mm. [ 1~180 0.6 2-1/4" 57 Al, B3, C4, D2, E5 .6 2-1/4" 57 Al, 83, C4, 02, E5 - - - NOTICE - Product Be1 Limited iiiu 10138 VKlOO 1/2" 15 mm 5.6 80.6 2-1/4" F 57 Al, B3, C4, 02, E5 - - - 10193 VK100 -- 15 mm 5.6 80.6 2-1/4" 1 57 Al, B3, C4, D2, E5 - -- - Approved Temperature Ratings A- 135 °F(57 °C), 155 "F(68 °C), 175 "F(79 °C), 200 °F (93 °C), 286 °F (141 "C), and 360 "F (182 Approved Finishes "C) 1 - Brass, Chrome, White Polyester 5, and Black Polyester B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 "C), 2 - Brass and Chrome and 200 °F (93 °C) 3 - Wax-Coated Brass and Wax Over Polyester' C - 286 °F (141 °C) 4 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient tem- 0 - 500 °F (260 "C)7 perature allowed at ceiling = 150 "F (65 °C) E - 155 °F (68 "C), 175 °F (79 °C), 200 °F (93 5- ENT5 °C), 286 °F (141 °C), 360 "F (182 "C), and 500 °F (260 "C)7 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kFa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colcrs. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar erclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 "C). the response time of the Ultra-High temperature rated sprinkler may be severely retarded. DfSlGN.CRITERIA - UL ~Alsc r'efe" t Appival Cist 1.) cULus Listing Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK100 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupaicies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. - Form No. F_052014 18.10,11 Rev 17.1.P65 Page 5 of 6 "tJ II(IF1G ® MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, 1-astings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-E464 Fax: 269-818-I80 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of Ihis technical data race: www.vikinggroupinc.com Approval Chart 2 (FM) T1 Micrornatic Standard Response Upright SprlmdEr VK100 K - Maximum 175 25j (12 bar) JVP AIX4 Sprinkler Base Thread Size Nominal K-Factor Overall Lergth FM Approvals' Part Number, SIN (Refer also to Design Criteria below.) NPT BSF U.S. I metric2 Inches mm Standard Orifice 12986 VK100 1/2' 15 mm 5,6 30.6 2-114" 57 Al, B27 C3, Dl, E4, F6 12993 VK100 -- 15 mm 5.6 . .30.6 2-1/4" 57 Al, Dl, E4, F6, G5 1t.1tI Limited Availability11Lo& Viking Office) 10138 VK100 1/2" 15 mm 5.6 30.6 2-1/4" 57 Al, B2, C3, Dl, E4, F6 10193 VK100 -- 15 mm 5.6 30.6 2-1/4" 57 Al, G5, Dl, E4, F6 Approved Temperature Ratings A- 135°F (57 °C), 155 °F (68 °C), 175°F (79 °C), 200 Approved Finishes I' °F(93°C) 212°F(100°C) 286 °F(141 °C), and 360 °F (182 °C) I - Brass, Chrome, White Polyester', and Black Polyester' B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F 2 - Wax-Coated Brass (corrosion resis:ait) (100 °C) 3-High Temperature 200°F (93 °C) ttax Coating (corrosion resistant); maximum ambient D -500 °F (260 °C)5 temperature ailcwed at ceiling = 150 F r65 °C) E - 155 °F (68 °C) 4- VVax-CoatEd Brass and Wax Over Pclyester4 F - 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286°F 5-White Polyester and Wax-Coated Eass (corrosion resistant) (141 °C), 360°F (182 °C), and 500 °F (260 °C)5 G-135°F(57°C),155°F(68°C),175°F(79°C),and 6- ENT6 200 °F (93 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured ri kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of print ng. Check witi the manufacturer for any additional approvals. Other colors are available on request with the same Approvais as the standard colors. Sprinklers of Ultra-High temperature rating are intenced for use inside ovens, dryers, or similar e,closures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM refor to jproeI Chort .; FM Approval Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK100 is is FM Approved as s:andard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ frm cULus and/or ."IFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI -3 for gen- eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, AFSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052014 18.10.11 Rev 17.1.P65 Wax Coated Upright Sprinkler Sprinkler wrench 135 must be used for ins wax coated sprinki Step 1: Carefully slic wrench sideways arou deflector, ensuring ei ment with the sprin wrench flats. V Page 6 of 6 L II(II1G® MICROMATIC® STANDARD l:IIrsqi..yy RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com ** A 1/2" ratchet is required Step 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Socket Wrench I 3577W/B for Wax Coated Sprinklers Form No. F052014 18.10.11 Rev 17.1.P65 Replaces Form No. F_052014 Rev 17.1 (Added P65 Warning.) U 3111111111111 25 25 25 25 - 1050 25 25 850 25 125j 15nrl 25 125 Watch a aideo derronstauon at www.itwbulldex.com Not less-thur 2' nominal width * No pre-drilling required. (1-1/2) up tc 3-1'2" pipe, not less than - - 3" (2-1,7) rjori i .al width 4"A 5" pipe Quick to install using the Sammy 4 Floor Jost Nut Driver with an 18V cordless Minimum 2-1/2 urorii bottom for - _________ dnll/driver. branch lines. Minimum 3 from bot- tom for main lines. Eizceptioo. Oh s Saves time from traditional - requirement snail notapply to 2" or methods. thicker nailing strips renting on top ot steel bearrs. Reduces installation costs. Marip in the U.S.A. 4111 I;Application Product Features - Eliminates distortion of threaded rod. _______________ • Accommodates up to 3 1/ x 12 pitch roof. Allows 17' deflection from vertical. Saves time from traditional methods, ANGLE SW Reduces installation costs Made in the U.S.A. MAX Roc Part Screw Ultimae UL Test Load FM Test Min Box Case Approvals Model h Size Number Descriptions Pullout (Ibs) Ilbs) Load (lbs) Thickness Cty City 914 Black - Lt.-/t> I ot06OT2O 1/4 iF 1475 25 125 Nut Driver . -f) 1 - . - --t#8113910 •, ' - - I 125 31 8269957 SH-GSTi2ST 21 5/16 a ; 25 125 - SH-GSI - . 25 it: - May requite "m-d illirg. :cnOutLjt,t manufacture..- 14 SJrarige Nut Drivu 'oil 9 82"' 1. Oft 411 SAMMYS FOR W1OD Wood Flooring • No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless "Shee~ock Joist • Saves time from traditional methods Ceilin j Reduces installation costs. 'Made in the U.S.A. - Wtch e vkleo de,0000r'aOoo or !— www.itwbuildex.com UltimateApprovals Rod Part Model Screw Size Number Descriptions Pullout UL Test FM Test Box Case __ 114 8002957 ( 100 1/4x 1 2 s) Load (Ibs) Load (Ibs) City City VEXTICAL MOUNT (7!i6 038) 25 125 [ 1,14' 800357 GST 2 1/4 K 2, 25 125 14x3 25 125 25 125 - 957 1760 1475 25 125 - uo925 ' 1760 25 125 6005925 -12' 2113 25 125 #14 Black 8016957 0 1475 25 125 Nut Driver - 8 8059925 Part#8113910 r T81 8011925 - - 12 8013925 Fr, 25 [ 1/2 0014925 s- (Fr) 25 — 1/2 8015925 GST3 1'4e3 2275 Fr 25 125 #149W/Sod Nut Driver Part #8114910 - QWAV SPECIAL NUT DRIVER SYSTEM: The out Jrive-s were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are irstalling irto, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use 01 the appropriate nut driver for installations. 1- #14 SW Rod Nut Driver Part # 8114910 Made with Teks° self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses, A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless ddlVdriver. I - 4'atch a virlao demonslration & 'I Manufactured in the U.S.A; . $'0Y wwwitwbulldex.comj 4 os,a,oc, rVA,rt 'o 114-1 v' "" 3 14 119 -' 2. 100' 114-2> 1 1 L, 3 19 3/16 1/4-14 1 TEKS 3 1477 (18 ga3 - 315 12o uu Li-SS 1/4-14> 1 TEKS 3 1477 (16 9>.) -- 3'l6 125 3.8 052957 SVD 20 1/4-14 x 2 TEKS 3 1477 (16 as.) 316 25 125 38 8055957 SWDR 1 -. 1/4-20> 1 TEES 3 1900 (20 ga) 1500 4 38 0354957 SO\DR 1-1/2 I 2->4 >1-12 TEVS >5'> 11 IC' I>> ,, L 38" 8055957 SWDR 515' 18> 1-1/4 3 - -. 147 036"- 20 ss 3/6' 8057957 SWT 15 12-24> 1-12 18 16") .188 -3/16' 1/2' 25 125 includes retaining nut Application Product Features - - ,,_-'7 • Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purtin allows threaded rod to hang plumb. 'Allows 17° deflection from vertical. Manufactured in the U.S.A. Watch a oWes demons Oation .vwwMwbuildex.com Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty Qty #14 Black F 3 -- 3137957 SH-DSTR 1' 3220 -' 1475 .035 316 Pao #8113910 - . 2368 (115' steel Vertical) 3'8 8268957 SI- - 122 1306(45' off Vertical( 1500 (Vertical) 4' 3t1E 1/2' 25 125 IF/CO 2281 (3/16 HSS) 850 (45° off aerl'cal) 2-12" 1586 (3/16' HSS 45' off Oe5Val) 2388 (1.2' steel Ver5ca 12 - H lEO 12-24> 1-3/4 (45 off Vnr' 25 125 - - TEES 5 1(316 HSS, 1/14 SR Drone - . - (316' HSS 45° off Veil ~ut Driver p -- a 82:73913 'DOeS not comply with ROHS requimmentn/Includes retaining out 14 S Note - Available in Electro-Galvanized and Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved. Fig. 98B - Rod Stiffener w/Break-off Bolt Head Seismic Restraints System Size Range - Secures 3/8 thru 7/8 hanger rod - - Material - Carbon Steel - - Function Secures hanger for - channel to rod vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and 'r Development (OSHPD). For additional load, spacing and placement ' information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines FIG. 98 Finish - Electro Galvanized Note - Available in HOG finish or Stainless Steel materials. - Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8' rod in 1 ' increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 HDG finish or Stainless Steel materials. 3/4 3230 Order By - Figure number, rod diameter, rod 7/8 4480 length and finish Fig 100- All Thread Rod Full Length Size Range - Secures 3/8 thru 11/2 rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5265 wwwtolco.com a" Fig. 200 — "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring C®US USTED Size Range - 1/2 thru 80 pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 thru 8) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2 thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/o 400 11 3/4 3/8 8mm or 10mm 31/a 21/2 400 11 1 3/8 8mm or 10mm 3% 2/e 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 1112 3/8 8mm or 10mm 37/6 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com D Victaulic® FireLockTM Outlet-T X04-c—tau-1ic~ Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 1 1/4 -21/2'1DN32—DN65 Threaded Outlet Sizes 1/2 /DN15, 3%'/DN20, and 1/DN25 NOTE IGS Grooved 1/DN25 Outlets available for this product. See jublication 10.54. Maximum Working Pressure 300 psi/2068 kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS coL E1 LLc @' u3n NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. H Location I Spec Section I I Paragraph Submitted By Date Approved Date victaulic.com 10.52 3355 Rev II Updated 06/2018 0 2018 Victaulic Company. All rights reserved. \/CtUIi victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Orange enamel (North America, Latin America, Asia Pacific). El Red enamel (Europe). El Optional: Contact Victaulic with your requirements for other coatings. Gasket': El Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: El Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). 10.52 3355 Rev H updated 06/2018 © 2018 Victaulic ComDany. All rights reserved. victaulic.com 2 victaulic.com S . 4.0 DIMENSIONS Style 922 Size ______ Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T V W Y Z (Each) inches inches inches inches inches inches inches inches lb ON mm mm mm mm mm mm mm kg 15 1/2 1.660 0.840 1 1,30 1 83 1 10 387 256 1 DN32 DN15 424 X 213 2 5vl 33 47 28 98 65 05 ~ 1.050 1.28 183 110 387 26 1 DN20 269 2 33 47 28 98 65 05 1 1 1 2 152 218 110 387 256 1 0N25 39 55 28 98 65 05 11/2 1/2 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 2 áx 1 36 50 31 104 65 0.5 ~ 1.050 2 hi 1.40 1.95 1.22 4.08 2.56 1 DN20 26.9 36 50 31 104 65 0.5 1 1.315 2 x 1 1.64 2.30 1.22 4.08 2.56 1 DN25 ! 42 58 31 104 65 0.6 2 1/ 2.375 0841 1.66 219 1.46 460 2.56 1 50 DN15 603 213 2 x1 42 56 37 117 65 0.6 1.05 1.64 2,19 1.46 4.60 2.56 1 DN20 26.9 42 5€ 37 117 65 0.6 1 131 188 2.51 1.46 460 256 2 0N25 33,7 48 6 .. 117 07 21/2 1/2 2.815 0.840 1.91 2.44 1.71 5.40 2.6 2 DN15 73.0 21.3 2 x1 49 62 43 137 65 0.7 3/4 I 1.050 1.89 2.44 1 1.71 5.40 2.56 2 DN20 26.9 2 x 11 48 62 43 137 65 0.7 1 ] 1.315 2.13 2.79 1.71 5.40 2.56 2 DN25 2 x 1 54 71 43 137 65 07 DN65 /2 3000 0.840 1.91 244 1.71 5.50 256 2 DN15 76.1 21.3 2 49 62 43 140 65 07 3/ 1 05 ' 1.89 2,44 131 5.50 256 2 DN20 269 48 62 43 140 65 0.7 1 1.31 213 279 171 550 256 2 33.7 13 X 54 71 43 140 65 '15 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NP threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 __________ victaulic.com p 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120) Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters jl/4 1 125 DN32 DN25 38 1½ 1 8.5 12.5 DN4O DN25 2.6 3.8 2 1 125 DN50 DN25 26 38 2½ 1 8,5 12.5 DN25 2.6 3.8 1 85 125 DN65 DN25 * 76 38 Hazen-Williams coefficient 01 friction is 120. 1 Firel-ock"I Innovative Groove System fIGS> outlet 6.0 NOTIFICATIONS WARNING Q Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm 1¼ All Outlet Sizes 30 32 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 ictsullilcr vtctaulic.com a • 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 I psi inches psi psi psi psi psi __ kPa - [ kPa 1 1/4 xY 300 300 300 '12 7'7 727 P\'2XDN15 2068 2068 100 1 1) 1¼x'/4 300 300 300 232 232 232 DN32XON20 2068 2 ' 068 • 2068 1 600 1600 .rn 1600 1'/4 X1 'I 300 - • 300 300 ....... 232 232 232 DN32 X DN25 2068 2068 - - 2068 1600 1 1600 1½x½ 1 300 300 300 232 I - - 1 232 DN40XDN15 j 2068 2068 2068 1600 1r 1600 1 i1x31~ 300 300 1. DN40XDN20 2 2068 1 ii ti 1½x1 300 DN40XDN25 2068 2068 2068 1600 1' 0 1600 2x½ 300 300 1 300 232 232 I 232 DN50XDN15 - 2068 - 2068 2068 1600 1600 1600 2x% 300 300 300 232 232 DN50X20 2068 2068 j 2068 11fl 'fl [ 1600 2 X, 300 300 300 - -2 232 DN50XDN25 2068 2068 2068 1 21/2 x 1h 300 300 300 232 232 232 2068 1 2068 2068 1600 - 1600 I 1600 2½x34 300 300 300 232 '2 r 232 2068 4 2068 2068 -- 1600 161)0 I 1600 2½x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 - 300 232 232 232 DN65XDN15 - - 2068 1020 1600 1600 300 - '32 232 232 L,pN65XDN20I - - 2068 1600 ] 1600 j 1600 300 232 232 232 .DN65XDN25 . . 2068 1600 1600 1600 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS ici,t,y,ikc,%si .iielgoitp.. G: 6de .. 2101: Victaiilic feror.s and Conditions of Sale -100 Installation lnstruct-ns -022 Installation Instructions Fii'eLock-51 Outlet-i User Responsibility for Product Selection and Suitability Note Loch user bears final respossibil:ly for shaking a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic spocilicotions. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with currant Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves tire right to change product specifications, designs and standard regulations as well as Victaulic performsiarice, maintenance, safety, and scorning equipment without notice and without incurring obligations. instructions. Nothing in this or any other docunrent, nor any verbal recommendation, - Installation advice or opinion front any Victaulic rnplokce shill be defamed to alter, vary, supersefte, Reference should always be math to the Vets Iic inst illalion handbook or r allatismr or waive any provision of Victsulic Corripany'o standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer, of Victaulic oroducts, providing complete installation and assembly data, and are available Intellectual Property Rights in POE format on WeCtral. No statement contained herein concerning a possible or suggested use of any material. Warranty product, serv.ce, or design in intended, or n"rould he constructed, to grant any license Refer to the Warranty section of the current Price List or contact Viclaulic for details. under any patent or other intellectual property right or Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use Of such Trademarks material, product, service, or design in the infringement of any patentor other intellectual Victaulic and all other Viclaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patsnts VictaLilic Company, and/or its affiliated enmities, in the U.S. and/sr other countries. or patent applications for articles and/sr methods of use in tire United States and/or other countries. 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 5 Aiictauh&