Loading...
HomeMy WebLinkAbout5909 SEA OTTER PL; 200; FPC2020-0014; Permitbty of Carlsbad I1ti11F1 4 % J- U1IJJE Print Date: 10/24/2024 Job Address: 5909 SEA OTTER P1, # 200, CARLSBAD, CA 92010-6675 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090820900 Track #: Valuation: $961,594.25 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0014 Status: Closed - Finaled Applied: 01/29/2020 Issued: 02/11/2020 Finaled Close Out: 04/08/2021 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: AIRSPACE TECHNOLOGIES -SPRINKLER TI (97 HEADS) Applicant: FPContractor: PACIFIC FIRE SYSTEMS INC PACIFIC FIRE SYSTMES INC DARIEN MORAN 12316 OAK KNOLL RD, # STE A 12316 OAK KNOLL RD POWAY, CA 92064-5364 POWAY, CA 92064-5363 (858) 722-9865 (858) 883-2333 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov F'aZcy2O -oot4 MATERIAL DATA SUBMITTAL Airspace Technologies Tenant Improvement 5909 Sea Otter Place Carlsbad, CA 92010 hCFI0 FIRE SYSTEMS, INC Pacific Fire Systems, Inc. 12316 Oak Knoll Road, Suite A Poway, CA 92064 858-883-2333 Phone. 858-883-2334 Fax November 16, 2010 F 041er41a MICROFAST® AND NiKi I1Gi MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 Pi y Approved: Calendar riumoer Li S-!O-Ik and Mk 89-92-L, Volume lb ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-C PD-40 170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41 d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http://www.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 06662B and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F_081296 Replces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 06720B.) Sprinkler 41 b November 16, 2010 MICROFAST® AND :RESPONSE icrofastHP® QUICK 'i IF(IIs1G PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°I57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 "Ff68 "C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B* (available since 2003) Optional Protective Sprtnkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. "A 1/2 ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® ant, MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fats Protective Sprinker Cap 10896 (0 Figure 1: Standard Sprinkler Wrench 10896W/B November 16, 2010 Sprinkler 41c MICROFAST® AND MicrofastHP® QUICK 4.111(1 MMM RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES 47 pnnklTempeatre fln Bulb Color - ~Te Ordinary 135 °F(57°C) 100 °F(38C) Orange Ordinary 155 °F(68 °C) 100 °F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the propcsed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon5 coatings. I / F7777777777771 F77777771 .. .......................... Sprinkler Wrench 12144W/B** For installing coated , I and/or recessed pendent sprinklers ,J Carefully slide the with protective caps 'L------- wrench sideways I around the protective I ] cap, ensuring engage- nent with the sprinkler wwA 1/2 ratchet is required wrench flats. (not available from Viking). Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d November 16, 2010 MICROFAST® AND MicrofastHP® QUICK N11UNG4 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval -ha I (UL) r--_mmPera KEY - ., F n oh Microfst ançMicrofastHPuIcesponse Pendent Sprinklers AIX -4 Escutcheon (f opphcabe) SIf(12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric2 Inches I mm cULus4 NYC5 VdS LPCB CE I Standard Orifice 1/2" 115 mm 5.6 80.6 2-1/4" 1 58 1 AIX, B1Y AIX, B1Y A3 A3X, B3Y C3X, E3Y11 C3X, E3Y13 Large Orifice 06666B I VK352 1 3/4" 20 mm 1 8.0 1 115.2 1 2-3/8" 1 60 1 AIX, B1Y I AIX, BIY I A3 I A3X I C311 -- 06765B I VK352 1 1/2" 1 15 mm 1 8.0 1 115.2 1 2-3/8" 1 60 1 AIX, B1Y I AIX, B1Y I A3 -- -- -- Small Orifice' 06718139 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AIX, B1Y AIX, B1Y -- -- - -- 06720B9 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AIX, BIY AIX, B1Y -- -- -- -- 06932B VK331 - 10 mm 4.2 57 2-3/8" 60 -- -- A3 -- G212 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric? Inches mm cULus4 NYC'- VdS LPCB CE 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX, B1Y AIX -- -- I -- -- Maximum 250 PSI (17 bar) WWP Small Orifice9 1229010 1 VK342 1/2" 15 mm I 2.8 40.3 1 2-3/16" I 56 1 AIX, BiY AIX -- -- I - -- Approved Temperature Ratings A - 135 "F (57 "C), 155 "F (68 "C), 175 °F (79 °C), 200 "F (93 "C), Approved Escutcheons and 286 "F (141 "C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 200 "F 1 - Brass, Chrome-Entoy®, White the Viking Microfast® Model F-i Adjustable Polyester67, Black Polyester87, Escutcheon C - 155 "F (68 "C), 175 "F (79 "C', 200 "F (93 "C), and 286 "F and Black Teflon (141 "C) Y - Standard surface-mounted escutcheon or D - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 286 "F 2 - Brass and Chrome-Enloy5 the Viking Microfast® Model F-1 Adjustable (141 "C) . 3 - Brass, Chrome-Enloy®, White Escutcheon or recessed with the Viking E - 155 "F (68 "C), 175 "F (79 "C), and 200 "F (93 "C) Polyester7, and Black Polyester7 Micromatic® Model E-i or E-2 Recessed F - 155 "F (68 "C), 175 "F (79 "C), and 286 "F (141 "C) Escutcheon G - 155 "F (68 "C) I Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 8 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. 10 psepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 ( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 11 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1008. 1/2' (15 mm) NPT 1-5/8' mm) (58 (41 mm) tJ W i 2' 1-1/2' (38.1 mm) (508 mm) Minimum Maximum November 16, 2010 Sprinkler 41e MICROFAST® AND MicrofastHP® QUICK '.1 IF(II1G RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESlGNCRlTERlA' UL refr tApproaP CLart1 Cn page"41d) cULus Listing Requirements: Microfast and MicrofastHP'5 Quick Response Pendent Sprinklers are cULUs Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F091699 - Care and Handling of Sprinklers. Also refer to page 011111-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 mm) minimum 2-1/8' I 2-1/2' (63.5 mm) maximum (54 Installed with a Pendent Sprinkler standard 1/8' surface- 06662B (VK302) mounted escutcheon, Installed with a Microfast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8' Ceiling Opening Size: (54 mm) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum 1-1/8' (286 mm) Minimum (44.5 mm) Maximum 1 - Installed with a Micromatic Model E-1 Recessed Escutcheon 2' \ft. ) ,fl/ 1-1/8' (28.6 mm) (50.8 mm) Minimum Maximum Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 41f November 16, 2010 MICROFAST® AND MicrofastHP® QUICK I KJ:N::C:*;] RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval €hart 2 (FM) - KEY - Microfast Quick'tResponse Pendent Sprinklers F l (Maxirum175S(12bar)WrNP Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals:' Base Part No.1 SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm Standard Orifice 06662B VK302 1/2" 115 mm 5.6 80.6 1 2-1/4" 58 A2X, 132Y Large Orifice 06666B VK352 20 mm 8.0 115.2 1 2-3/8" 60 I AiX, B1Y Small Orifice4 06718B6 VK329 1/2" 15 mm 2.8 40.3 2-3/16" I 56 AiX Approved Escutcheons Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon orthe Viking A- 135°F (57 °C), 155°F (68 "C), 175°F (79 °C), 1 - Brass and Chrome-Enloy Microfast5 Model F-i Adjustable Escutcheon 200 "F (93 °C), and 286 °F (141 °C) 2- Brass, Chrorne-Enloy', White Polyester5, V - Standard surface-mounted escutcheon or the °F °C), °F °C), °F °C), B - 135 (57 155 (68 175 (79 and Black Polyester5 Viking Microfast Model F-i Adjustable Escutcheon °F °C) and 200 (93 or recessed with the Viking Micromatic Model E-i or E-2 Recessed Escutcheon Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. ,;DE5lGNCRITERlA-:FM - , '-Fo 'f r toproI Chart 2 above ,6 FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. tSpnnklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated October 8, 2010. (Updated deflector material for PN 06720B.) April 8, 2011 picoW -oOt4 Sprinkler 54a MIRAGE® STANDARD AND QR CONCEALED PENDENT "4jJ FJ Is1J SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-pro- file cover assembly that provides up to 1/2 (12.7 mm) of vertical adjustment. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 ({Pce) LPCB Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to Approval Chart 1 and Design Criteria on page 54c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54d for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65'F (-55°C) Patents Pending *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMethc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Viking Technical Data may be found on Phosphor Bronze UNS-051000 for Sprinkler VK463 The Viking Corporation's Web site at Deflector Pins: Stainless Steel Alloy http://www.vikinggroupinc.com. Bulb: Glass, nominal 3 mm diameter The Web site may include a more recent Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel edition of this Technical Data Page. UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-05 1000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F103005 Replaces page 54a-f, dated February 25, 2011. (Revised LPCB Approval. Removed UL listing from 165 °F Cover 15394. Obsoleted sprinkler 14697.) Sprinkler 54b April 8, 2011 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP I F(J I'IG SPRINKLER VK463 (K5.6) The Vidng Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C 11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking MirageQ Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°I68° = B, 175°/79° = 0, 200°/93° = E For example, sprinkler VK463 with a 155°F/68°C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B I Temperature Suffix (°F/°C): 135°/57° UL (139'/59* FM and LPCB) =A, 165°/74° = C For example, cover 13504 with a Polished Chrome finish and a 165°F/74°C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135°F (57°C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/13 (available since 2006), or Head Cabinet Wrench Part No. 14031' (available since 2006) Optional Concealed Ccver Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 11z ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 :and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. April 8, 2011 Sprinkler 54c The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES I 1Sprinklrnaal ' xu n Ternperatureting of Cover Classification Temperature Rating' Ce,ling Temperature I Assembly (Required Bulb Color Ordinary 155°F (68°C) 100°F (38°C) Red 139°F(59°C)FM and LPCB Intermediate 175°F (79°C) 150°F (65°C) 165°F (74°C) Yellow Intermediate 200°F (93°C) 150°F (65°C) 165°F (74°C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. CUS ((0)) Identification of Custom Point Colon All custom color pointed cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint dot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers 3D NOT PAINT 3-5/16 (84,1 mm) Figure 2: Square Cover Assembly 15394 Sprinkler 54d April 8, 2011 MIRAGE® STANDARD AND s QR CONCEALED PENDENT j I FI F4#1Gu SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Apro1'C hr1 (UL) •-- Cver Plate TemsteRating mirag"~.f.-Coneealed Pendent Sp.r,ln~l 46 AW 14 F'ni KEYI I NPT Thread 1 - Nominal Maximum Listings and Approvals4 Sprinkler I SIN I Size I K-Factor I Water Working L (Refer also to Design Criteria below.) Inch I mm U.S. metric' cULus' NYC VdS LPCB I CE Base Part No.1 Pressure Standard Response Applications 13503A VK462 1/2" 15 5.6 80.6 1 175 psi (12 bar) I -- -- AY1, CZ1 AY1, BZ1 AY1, CZ17 Quick Response Applications 13503A VK462 I 1/2" 15 I 5.6 I 80.6 I 175 f5I (12 bar) AV1, BX1 AV1, BW16-- 13667A I VK463 I 1/2" 15 5.6 I 80.6 1 250 psi (17.2 bar)3 I AV1, BX1 I AV1, BW16-- Cover Plate Assembly Temperature Ratings' Cover Plate Assembly Finishes' Sprinkler Temperature Ratings V - 135°F (57°C) cULus Listed cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, or 153941 (square cover plate) A- 155°F (68°C) W- 165°F (74°C) cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, B - 175°F (79°C) and 200°F (93°C) X - 165°F (74°C) cover 135041, or 136421 (large diameter) Brushed Brass, Brushed Copper, C 200°F (93°C) Y - 135°F (57°C) cover 135041 LPCB Approved as 139°F (59°C) Painted White, Painted Ivory, or Z - 165°F (74°C) cover 135041 Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 The 135/139 °F cover has an orange label. The 165 °F cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are, available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. - '. .. DES GN:CRlTERIAc-UL. Al ri refer toAppoval Chart 1 abc cULus Listing Requirements: Mirages Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. April 8, 2011 Sprinkler 54e " MIRAGE® STANDARD AND QR CONCEALED PENDENT I IF(IFsIG SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approva1Chart2 (FM) Mirages Standa1 Responc ConcealedlPendent Sprinkler VK462 AW1.*Rt F F KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metnc2 Pressure 13503A VK462 1(2" 15 5.6 80.6 175 psi (12 bar) AW1,BX1 Cover Plate Assembly Temperature Ratings4 Cover Plate Assembly Finishes' Sprinkler Temperature Ratings w- 139°F (59°C) cover 135041, 136421 (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68°C) or 153941 (square cover plate) Brass, Antique Brass, Brushed Brass, B - 175°F (79°C) and 200°F (93°C) X - 165°F (74°C) cover 135041, 136421 (large diameter), Brushed Copper, Painted White, Painted or 153941 (square cover plate) Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139°F cover has an orange label. The 165°F cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. - . DESIGN CRITERIA - FM -- -- ' - -, . '. '1 - . 'I u refer to Approval Tchart t FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F,...091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler Frame Arms Sprinkler Wrench Flat NEVER install the sprinkler by applying the installation Wrench across the frame arms. Sprinkler 54f April 8, 2011 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP N4 I l(I I1G SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 2-1/4' (572 mm) diameter opening Is required in the ceiLing. bly ap Ase Sprinkler Wrench <Part No 4047 Is shown) EA 1/2' ratchet s required (not ilable from Viking) Step 2' Carefully press the Step 1' Carefully slide the wrench upward and turn slightly wrench sideways around to ensure engagement with the the deflector and pins, sprinkler wrench flats. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. DO NOT apply more than 25 ft lbs. of torque. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Correct Use of Wrenches 1/2' (15 mm) NPT 2-3/16' (55 mm) 2-1/16' (52 mm) Minimum 3/4' (70 mm) o 3-5/16' (84.1 mm) Note' Upon sprinkler activation, the deflector descends to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 Replaces page 54a-f, dated February 25, 2011. (Revised LPCB Approval. Removed UL listing from 165 OF Cover 15394. Obsoleted sprinkler 14697.) iCZo2O —014 Page i of 6 'I II(ING® MICROMATIC® STANDARD III['1iU.7V RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Micromatic® Standard Response Upright VK100 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. LISTINGS AND APPROVALS c®us cULus Listed: Category VNlV FM Approved: Classes 2001, 2002, 2015, 2017, 2043 WARNING: Cancer and Reproductive Harm- /Aq NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring - Exposed, Screw and Pipcap - ENT plated. ttNot for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® Standard Response Upright VK100 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-N\/, ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C) = H, 500 °F (260 °C) = L. For example, sprinkler VK100 with a 1/2" thread, Brass finish and a 155 F (68 °C) temperature rating = Part No. 12986AB Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F_052014 18.10.11 Rev 17.1.P65 Replaces Form No. F_052014 Rev 17.1 (Added P65 Warning.) Page 2 of 6 'tJ II(JF,.1G® MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B (available since 2000) Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/Be (available since 2006) *A W' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly: Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic5 Standard Response Upright Sprinkler VK100 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Cap - Wrench Flat Standard Sprinkler Standard Sprinkler Wrench for Wax Wrench 21475M/B Coated Sprinklers 10896W113 Figure 1: Standard Sprinkler Wrenches Form No. F_052014 18.10.11 Rev 17.1.P65 Page 3 of 6 MICROMATIC® STANDARD A A RESPONSE UPRIGHT 'J I KI W4j SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES -- Sprinkler Temperature ' Sprinkler Nominal i- '5 - Maximum Ambient Classifiation Temperature' Rating - Ceiling Temperature Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F(182°C) 300 °F(149°C) Mauve Ultra High' 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyester' for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax5 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 F (149 °C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Wax melting point is 170 °F (76 °C) for 286 °F (141 C) temperature rated sprinklers. Form No. F_052014 18.10.11 Rev 17.1.P65 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) .-- Temperature - Finish 7KE Micrcmatic'- Stan'da RdspsjUpg hiSprinkler VKIOO Escuheor ( Maximum _75 PSI 2bar)WvVP -- Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part SIN (Refer also to UL Design Criteria.) N mber1 NPT BSP U.S. metric2 Inches I mm cULus' VdS LPCB CE Standard Orifice 12986 VK100 1/2" 15 mm 1 5.6 80.6 2-1/4" 57 Al, B3, C4, D2, E5 - -- -- 12993 VK100 - 15 mm 5.6 80.6 2-1/4" 57 Al, B3, C4, D2, E5 - -- NOTICE - Proyl 1:If Limited (Contact Local Viking Office) 10138 VK100 1/211 " 15 mm 1 5.6 80.6 2-1/4" 1 57 1 Al, 133, C4, D2, E5 - -- - 10193 VK100 - 15 mm 1 5.6 80.6 1 2-1/4" 1 57 Al, 63, C4, D2, E5 - -- - Approved Temperature Ratings A- 135°F (57 "C), 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 Approved Finishes °C) 1 - Brass, Chrome, White Polyester56, and Black Polyester58 B - 135 °F (57 °C), 155 'F (68 'C), 175 'F (79 'C), 2 - Brass and Chrome and 200 'F (93 °C) 3 - Wax-Coated Brass and Wax Over Polyester' C - 286 'F (141 'C) 4 - High Temperature 200 'F (93 °C) Wax Coating (corrosion resistant); maximum ambient tern- D - 500 'F (260 °C)7 perature allowed at ceiling = 150 °F (65 'C) E - 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 5- ENT5 °C), 286 'F (141 °C), 360 °F (182 °C), and 500 'F (260 'C)7 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metiic K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F (149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 'F (149 'C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. DESIGN CRITERIA - UL cULus Listing Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK100 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052014 18.10.11 Rev 17.1.P65 S Page 5 of 6 41KJNG4 MICROMATIC@ - STANDARD l.l:II[.1i•iyw RESPONSE UPRIGHT SNPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart .2 (FM) Tempersture KEY Mieromtic Standard Response Upright Sprinkler VK100, f - rsh Maximum 175_PSI (12 bar) WWP AX4—EscuicheanfapptcabIe) Sprinkler Base T Thread Size fNominal K-Factor Overall Length FM Approvals Part Number1 SIN (Refer also to Design Criteria below.) NPT BSP U.S. I metric, Inches mm Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 1 2-1/4" 57 Al, B2, C3, Dl, E4, F6 12993 VK100 -- 15 mm 5.6 80.6 2-1/4" 57 Al, Dl, E4, F6, G5 ItNOTICE Product IBelow lTh7 ;v.iny. (Contact Local Viking f.JIff 10138 VK100 1/2" 15 mm 5.6 80.6 2-1/4" 157 Al, B2, C3, Dl, E4, F6 10193 VK100 - 15 mm 5.6 80.6 2-1/4" 1 57 Al, G5, Dl, E4, F6 Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200 Approved Finishes °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C) 1 - Brass, Chrome, White Polyester', and Black Polyester' B - 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F 2 - Wax-Coated Brass (corrosion resistant) C-286°F(141°C) °C) 3-High Temperature 200°F (93 °C) Wax Coating (corrosion resistant); maximum ambient D -500 °F (260 °C)5 temperature allowed at ceiling = 150 °F (65 °C) E - 155°F (68 °C) 4-Wax-Coated Brass and Wax Over Polyesters F - 155°F (68 °C), 175 °F (79 °C), 200°F (93 °C), 286 °F - White Polyester and Wax-Coated Brass (corrosion resistant) (141 °C), 360°F (182 °C), and 500 °F (260 °C)5 6- ENT6 G-135°F(57°C), 155°F(68°C), 175°F(79°C),and 200 °F (93 °C) Footnotes 1 Base part number is shown. For Complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. DESIGN CRITERIA FM els° i efFr tr3Ap l flhT1 FM Approval Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK100 is is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for gen- eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052014 18.10.11 Rev 17.1.1365 Page 6 of 6 N41KING*MICROMATIC@ STANDARD lsi:II[.n•.yly RESPONSE UPRIGHT SPRINKLER VKIOO (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler wrench 13577W/B** must be used for installing wax coated sprinklers. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. Wax Coated Upright Sprinkler ** A 1/2" ratchet is required Step 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Socket Wrench 13577W/B for Wax Coated Sprinklers Form No. F_052014 18.10.11 Rev 17.1.P65 Replaces Form No. F_052014 Rev 17.1 (Added P65 Warning.) FM Approved and Fully Listed Sprinkler Pipe Wheatland's WLS steel fire sprinkler pipe is hot-dip galvanized to meet FM requirements for dry systems and is UL. C-UL and FM Listed. Approvals and Specifications The product meets or exceeds the following standards: ASTM: A795, Type F, Grade A ANSI/ASME B1.20.1 pipe threads NFPA13 Manufacturing Protocols WLS is subjected to the toughest possible testing protocols to assure the highest quality and long-lasting performance. Finishes and Coatings WLS is finished in black or hot-dip galvanized. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SPECIFICATIONS NIPS NOM OD NON ID UL CRR WLS SchedtiIeSchduIe ,ScheduIe:rN,In-&7 Pcs./ Pcs.I 10 40 WLS 40 wt /ft LIft 21 1 Z Lift 25 1 1.315 1.087 N/A 1.049 57 100 1462 70 60 w4,j 1660 1.426 1.442 1.380 46 100 1.928 55 45 1% 1.900 1.650 1682 1.610 64 100 2.370 45 40 1 2 2,375 2.125 2.157 2,067 .52. 1.00 - 3.004 . 30. Calculated using Standard UL CRR formula, (IL Fire Protection Directory, Category VIZY. & C & < > .... .... PROJECT: CONTRACTOR DATE ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK F1 HOT-DIP GALVANIZED P 800.257.8182 I vhtln ha SiT43W1IMWE$j Not less than 2' nominal width (1-1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5 pipe 4 Ftusr Joist -II Minimum 2-1/2' from bottom for branch lines. Minimum 3' from bot- tom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. Consuhl No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. '' WaSh o idao damo,,soahon -, -. wwwitwbuildex.comJ :[,1lMI]yuugr.1uja 1/4' 8019957 SWG 200 1/402' 1725 (Fir) 25 125 3/8 2095 'SWG 1/4w °° (Fir( T300 2 125 a 3/8" 8021957 SWG 20 1/40 2" 1 5 (Fir) 1050 25 - 125 L 8To 92 TT 742 (Fir) 25 125 3/8" 8022925 SWG 25-380 3/80 2-1/2' 2249 (Fir) 1500 25 125 #14SWRed 8 02392 SWG30 4X " 884 7 25' 5 Nut Driver Part # 8114910 mr - 1/2' 8ju39E May require pre-drilling; consult joint manufacturer. 1/4s2 1257 (Fir) 1050 1475 25 125 1I4o 1720 (Di)1475T_25 125 1903 Dim. Lumber 1500 5/16x 1-3/4' 1406 @ 45'off vertical 850 @ 45 25 125 Dim. Lumber 903 Dim: Lumber 5I16 x;-. 1405 l45'off vel vl 25 125 Dim. Lumber -- - Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8' pipe. Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2') Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2 thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/a 400 11 3/4 3/8 8mm 0r10mm 3½ 21/2 400 11 1 3/8 8mm or 10mm 33/8 2% 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 3½ 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/s 41/6 600 27 3 3/8 10mm 57/s 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 10½ 63/4 1250 73 8 1/2 12mm 131/s 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737,0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com