HomeMy WebLinkAbout5909 SEA OTTER PL; 100; FPC2017-0142; PermitPERMIT REPORT 100=k yof Carlsbad Print Date: 10/24/2024 Permit No: FPC2017-0142 Job Address: 5909 SEA OTTER P1, # 100, CARLSBAD, CA 92010-6674 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090820900 Track #: Applied: 05/30/2017 Valuation: $1,591,432.67 Lot Th Issued: 07/12/2017 Occupancy Group: Project #: Finaled Close Out: 04/08/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Stowe, Daniel Plan Check #: Wong, Cindy Project Title: Description: SYNTERACT - FIRE ALARM Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC JEFF RODGERS 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (858) 560-7000 FEE AMOUNT FIRE New Alarm System $1,227.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $1,414.00 Total Payments To Date: $1,414.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov 4 HCI Systems Inc. FIRE I LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: SYNTERACT 5909 SEA OTTER PLACE SUITE 100, CARLSBAD, CA 92010 FPC20I7-0142 5909 SEA OTTER PL UNITIOO Ontario • San Diego • Irvine • Hayward • Burbank • Fresno • Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Website: www.hcisysfems.net SYNTERACT 5909 SEA OTTER PLACE SUITE 100, CARLSBAD, CA 92010 Manufacturer Device Model # Description C.S.F.M. # EDWARDS BPS6A BOOSTER POWER SUPPLY 73001657:0229 EDWARDS SIGA-PS PHOTOELECTRIC SMOKE DETECTOR 7272-1657:0126 EDWARDS SIGA.DH DUCT SMOKE HOUSING 3240-1657:0108 EDWARDS SIGA-DTS DUCT TEST STATION 7300-1657:0127 EDWARDS SIGA-CRH CONTROL RELAY HIGH VOLTAGE 7300-1657:0121 EDWARDS SIGA-CC1S SYNCHRONIZED INPUT SIGNAL MODULE 7300-1657:0121 EDWARDS GCF-VM MULTI-CANDELA STROBE 7125-1657:0219 EDWARDS GCF-HDVM MULTI-CANDELA HORN/STROBE 7125-1657:0202 HCI Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: SYNTERACT 5909 SEA OTTER PLACE SUITE 100, CARLSBAD, CA 92010 Ontario • San Diego • Irvine • Hayward • Burbank • Fresno • Sacramento Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Websife: www.hcisystems.net SYNTERACT 5909 SEA OTTER PLACE SUITE 100, CARLSBAD, CA 92010 Manufacturer Device Model # Description C.S.F.M. # EDWARDS BPS6A BOOSTER POWER SUPPLY 7300-1657:0229 EDWARDS SIGA-PS PHOTOELECTRIC SMOKE DETECTOR 7272-1657:0126 EDWARDS SIGA-DH DUCT SMOKE HOUSING 3240-1657:0108 EDWARDS SIGA-DTS DUCT TEST STATION 7300-1657:0127 EDWARDS SIGA-CRH CONTROL RELAY HIGH VOLTAGE 7300-1657:0121 EDWARDS SIGA-CC1S SYNCHRONIZED INPUT SIGNAL MODULE 7300-1657:0121 EDWARDS GCF-VM MULTI-CANDELA STROBE 7125-1657:0219 EDWARDS GCF-HDVM MULTI-CANDELA HORN/STROBE 7125-1657:0202 SPACE AGE ACE-il FIRE ALARM DOCUMENT CABINET 7300-0553:0110 Imp LIFE SAFETY INCIDENT MANAGEMENT Remote Booster Power Supplies' (BPS6A) BPS10A EDWARDS Catalog D Power Supplies and Accessories :TT Tiith1 ' i.iflI1 z 1/ MEA 476-91-E Vol. 13 1! * 7300-1657: 0229 Overview The Booster Power Supply (BPS) is a UL 864, 9th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS'S unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition (UO)O<)Fire Alarm Systems UL636 (ANEr, UEHX7) Holdup Alarm Units and Systems UL609 (AOTX, AOTX7) Local Burglar Alarm Units and Systems UL294 (ALW, UEHX7) Access Contro Systems UL365 (APAW, APAW7) Police Station Connected Burglar Alarm Units and Systems UL1076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1610 (AMCX) Central Station Alarm Unit ULC-5527 tiöC) Control Units, Fire Alarm (Canada) ULC-S303 (AOTX7) Local Burglar Alarm Units and Systems (Canada) 022.2 No. 205 Signaling Equipment (Canada) Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page lof4 DATA SHEET E850050125 Not to be used for installation purposes. Issue 1 Power-limited wiring area Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. Dimensions Top View J 00 D2-'1 Ii D3 o &4- D4 —*8 e Front View > 1) °D6 0 S All knockouts for 3/4 in conduit (1.9 cm)CD Dl BPS NACs can be configured for a 3-3-3 temporal or continuous output. California temporal rate outputs are also available on cer- tain models. This makes the BPS ideal for applications requiring signaling rates that are not available from the main system. Dl D2 D3 D4 D5 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) D6 12.0 in (30.4 cm) Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety and security applications, and the capacity of 65 ampere- hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 VdO power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 Notes 1 Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs, The BPS enclosure has mounting brackets for up to three Signa- ture modules to the tight of the circuit board. Route AC supply through these knockouts only (Nonpower-limited and supervised) Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the booster's terminals. This allows multiple boosters to be driven from a single NAC circuit without the need for special configurations. NAC Circuit I __________________ To next signaling NAC Circuit I device, booster, or EOL resistor CD CD NAC output #1 Fire Al arm ) NAC output #2 Control Panel 0I cn CD I > NAC output #3 r)l ) NAC output #4 C C Booster Power Configuring the Booster for AC Power Fail delay operation* NAC1/+ AUX1 - NAC2/ + AUX2 - NAC3/ +:9- AUX3 - NAC4/ + AUX4 - 200 mAAUX Continuous lN Sense 1 COM OUT IN Sense COM OUT No Trouble COM VNC 0 T131Notification appliance circuit (NAC) UL listed :::jIIIIj Notification appliance circuit (NAC) ULhsted 1011111 1 )EOL 47 kO - 109 CC1(S) module [1][3] 00 4321 h ITMA - t E ___________ - - - Eff L [9: Fff Multiple CC1 (5) modules using the BPS's sense inputs IBi Notification appliance circuit (NAC) NAC1/ + UL listed AUX1 - EOL15KW NAC2/ + AUX2 - NAC3/ + AUX3 - NAC4/ + AUX4 - 200 mAAUX Continuous IN Sense 1 COM OUT IN Sense 2 COM OUT NO Trouble COM NC CC1(S) module 00 [3] LmO 14111 previous device 5j Data out to ii • • • II Data in from \J I —* next device or Signature 3 2 controller Data in from previous >JItI Data out to The Booster supports AC Power fail delay device or Signature of three hours via its trouble contact when controller > next device dip switch SW2-6 is on. All other troubles are reported to supervising module or panel without delay via sense inputs. Notification appliance circuit 47 K 47 K -+ 109 CC1(S) module 00 UL listed EOL 15 KW Security and access BPS TB1 24 V 12V NAC1/ + ::1 6 24DC12 6 Security =device AUX1 - NAC2/ + AUX2 - NAC3I + AUX3 - NAC4/ + AIIVA -FW Control panel [11 Disable the BPS's ground fault jumper (JP3) E Security EOL deviice ]:=itoring device Card reader Card reader controller controller BPS [11 I ________ Card reader I controller I To next device or end Page 3 of 4 DATA SHEET' E85005-0125 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Model 6.5 amp Booster 10 amp Booster AC Line Voltage 120VAC or 220-240VAC 50760Hz 12OVAC or 220-240VAC 50/60Hz 390 watts 580 watts Notification Appliance 3.OA max. per circuit @ 24Vdc 3.OA max. per circuit © 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 1 O max total all NACs Trouble Relay 2 Amps © 30Vdc Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current 3mA © 12Vdc, 6mA © 24Vdc (from an existing NAC) Booster Internal 70mA + 35 mA for each circuit set to AUX Supervisory Current Booster Internal Alarm 270mA Current Signature Mounting Space Accomodates three two-gang modules. Maximum Battery Size 10 Amp Hours (2 of 12V1 CIA) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing @ 32°C Temperature Rating 32° to 120°F (0° to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model BPS°CAA provides selection for California rate, in place of temporal. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description Number Shipping Wt. lb (kg) BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply (ULC) 13 (5.9) BPS6N230 6.5 Amp Booster Power Supply (220\) 13(5.9) BPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) BPS10A 10 Amp Booster Power Supply 13(5.9) BPS1 OAC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 0N230 10 Amp Booster Power Supply (220V)- 13(5.9) BPS1 0CM 10 Amp Booster Power Supply with California rate 13(5.9) Requires installation of sepa- rate battery cabinet. BPS supports batteries greater than 24 Amp hours for access control applications only. For earthquake anchorage, including detailed mounting weights and center of gravity detail, refer to Seismic Applica- tion Guide 3101676. Approval of panel anchorage to site structure may require local AHJ, structural or civil engineer review. Related Equipment 12V6A5 7.2 Amp Hour Battery, two required 3.4(1.6) 12V1 OA 10 Amp Hour Battery, two required 9.5(4.3) 3-TAMP Tamper switch - BC-i EQ Seismic Kit for BC-i. Order BC-i separately. See note 3. BPSEQ Seismic kit for BPS6A or BPSi 0 Booster Power Supplies. See note 3 BC-1 Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) 12V24A 24 Amp Hour Battery, two required (see note 1) 20(9.07) 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40(18.14) 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) Page 4ot4 DATA SHEET E850050125 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 0-1657:09 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: ModelsfPS6A) BPSIOA, BPS6A/230, BPSI0A/230, BPS6CAA, and BPSIOCAA remote booster power supplies. *Models APS6A, APS6A/230, APS6CAA, APSIOA, and APS10A/230 Auxiliary Power Supply. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:229 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S853 * 7272-1657: 0126 I F 'FIANIPME" 05 Livew ies mww EDWARDS Catalog ' Intelligent Initiating LIFE SAFETY INCIDENT MANAGEMENT Intelligent Photoelectric Smoke Detector LSIGA-PS) Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detectors on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Page lof4 DATA SHEET E850010269 Not to be used for installation purposes. Issue 1 Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- ean BESA and 1-gang boxes with 60.3 mm fixing centers. J OEM mm) (51 mm) 4.4 012 mm) Tamper-Resist Lever m - Break oft to disable - (Located on Base) - Access Slot for Tamper-Resist Mechanism Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a 'dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- Lirements which must be conducted at the end of the first year nd every two years thereafter. he user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SlGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the 'room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SlGA-SB4, SlGA-RB4, and SlGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SlGA-AB4G mounts to a 4" sqare box only. VIV SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- ing base for EDWARDS Signature Series detectors. The SIGA- LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SlGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SlGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-I134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SlGA-LED - The remote LED connects to the SIGA-SB or SlGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Page 2of4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. EDWARDS recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-PS Photo Rise! Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood unsuitable optimum very suitable optimum Wood Pyrolysis optimum unsuitable optimum optimum Smoulderinci Cotton optimum unsuitable ootimum optimum Poly Urethane Foam very suitable suitable very suitable optimum ontimum Liquid Fire without unsuitable optimum very suitable very suitable Smoke Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 Normally- Normally- CAT UtWN Iii ti) From Signature Controller or Previous Device Remote LED Max resistance *__ per wire - must not exceed 10 Ohms Term Description 1 Not Used 2 DATA IN/OUT 1+) 3 Not Used 4 DATA IN(-) 4 Remote LED (-) 5 Remote LED 1+) 6 Not Used 7 DATA OUT (-) Term Description 1 Normally Open 2 DATAIN/OUT (+) 3 Common 4 DATA IN (-) 5 Not Used 6 Normally-Closed 7 DATA OUT (-) CONTACT RATING 1.0 Amp @30 VDC OUT C-) (Pilot Duty) OUT (i-) To Next Device IN N1 \\J I DATA OUT (-I DATA IN 1+) DATA OUT 1+1 From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-1113, SIGA-1134 Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used DAI DATm uu ¼') From Signature Controller or Previous Device Audible Detector Base, SIGA-AB4G oo ® Volume setting Tone setting Default = High volume Default = Temporal pattern I - Cut for steady tone now Cut for low volume tone, cot the Ct,xu board =figu re figure output volume lt as shown. 24 Vdc in - From power supply or previous base Data in From Signature controller or previous device OUT (+) To Next Device OUT (-) 24 Vdc out To next base or EOL relay Data out To next Signature device Page 3 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 Specifications 93 B Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Air Velocity Range: 0 to 5,000 ft/mm (0 to 25.39 m/s); Humidity: 0 to Environment 93% RH, Non-Condensing Operating Temp: 32"F to 120°F (0°C to LIFE SAFETY & INCIDENT MANAGEMENT 49°C); Storage Temp: -47to 140"F(-20"Cto 60°C) Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot Contact us... User Selected Alarm Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Email: edwards.fire@ls.utc.com Sensitivity Settings Less Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. Web: Edwards-fire.com Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) EDWARDS is a UTC brand. {QperatingCurr) çQuiescent: 45pA @JV.Alarm: 45pA @ 19 V. Puke Current: 100 pAJ 1016 Corporate Park Drive ((i0Qrnsec), During Communication: ,9mArnax Mebane, NC 27302 Construction & Finish High Impact Engineering Polymer - White Compatible Mounting SIGA-SB Standard Base, SlGA-RB Relay Base, SIGA-113 Isolator Base, © 2016 United Technologies Corporation. Bases SIGA-AB4, SlGA-AB4G Audible Bases All rights reserved. LED Operation On-board Green LED - Flashes when polled: On-board Red LED - Flashes when in alarm. Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm. Compatibility Use With: SIGNATURE Loop Controller Address Reauirements Uses one Device Address UL Listed Sacinq 30 ft Ordering Information Catalog Description - - - Ship Wt. - Number lbs (kg) (SIGA:Ps) Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SlGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2 (.09) SIGA-113 Detector Mounting Base w/Fault Isolator SlGA-1134 4-inch Detector Mounting Base w/ Fault Isolator, /w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SlGA-AB4G Audible (Sounder) Base .3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) .1 (.04) Page 4of4 . DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7272-1657:0126 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: Model SIGA-PHS is not intended for use in lieu of a required heat detector. Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division E ~Aw ffi FM' HIM 0- Li Ujh no, ies EDWARDS Catalog D Intelligent Initiating LIFE SAFETY , INCIDENT MANAGEMENT Intelligent Duct Smoke Detector Housing SIGA-DH [L 3257: > MEA S853 0108 Overview The SIGA-DH Duct Smoke Detector Housing is specially engi- neered to exploit all the capabilities of Signature Series intelligent photoelectric and multisensor smoke detectors. EDWARDS Signa- ture Series detectors gather analog information from each of their one or more sensing elements and converts it into digital signals. The detector's onboard microprocessor measures and analyzes these signals. It compares them to historical readings, time pat- terns and known characteristics to make an alarm decision. Digital filters and complex Algorithms are applied for optimum detector accuracy. Unwanted alarms are virtually eliminated. Each duct housing is packaged with detailed installation instruc- tions, gaskets and a self-adhesive drilling template for locating and mounting the detector. The large access door is completely re- movable to allow fast detector Installation and field wiring connec- tions. The 16 gauge steel housing is finished in red baked enamel for easy identification,, Five one-gang knockouts on the housing provide a convenient location for mounting intelligent Signature Series modules. The SIGA-DH Duct Housing comes with a 6 inch (150 mm) exhaust tube. Air sampling tubes are available in lengths from 8 inches (200 mm) to 10 feet (3048 mm) and must be ordered sepa- rately. Compatible smoke detectors, mounting bases, and acces- sories are listed in the Ordering Information. Refer to individual device catalog literature pages for more detail. Standard Features Suitable for high air velocity duct applications Up to 4000 ft/mm. (20.3 rn/sec.) with Photoelectric Detector. Standard Signature Series detectors Designed for use with standard 4D, 3D, and Photoelectric Signature Series smoke detectors. Does not require special' duct smoke heads. Standard, relay, or isolator detector base Detector plugs-in to base then easily installs into housing. Install inducts up to 10 ft. (3.05 m) wide Remote LED and test station accessories Designed and manufactured to ISO 9001 standards Typical Wiring The detector mounting bases and test station will accept #18 AWG (0.75mm1, #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5 mm wire sizes. Note: #14 AWG (1.5 mm2) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page 1 of 4 DATA SHEET E85001-0325 Not to be used for installation purposes. Issue 1 Application The SIGA-DH Duct Smoke Detector Housing requires a clear, flat, accessible area on the duct of at least 7-3/8 inches (188mm) W x 7 inches (175mm) H. The duct housing must be installed on ducts at least 8 inches (200mm) wide. Duct detectors are usually installed on the supply duct after the air filters; or in the return air stream prior to being diluted by outside air. Sample tube length must span the entire width of the air duct and the tube can be easily cut to any length. Inlet tubes longer than 3 ft.(900mm) must be supported at both ends. Duct detectors continually sample air flow in a HVAC duct and initiate an atari-n condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting Air velocity in the duct maintains the air flow that enters the detec- tor housing through perforations in the air sampling inlet tube and discharges through the outlet exhaust tube. The detector housing must be installed with its INLET air sampling tube upstream of the EXHAUST tube. Before installing the duct detector housing, test the duct air velocity to verify it is within the limits of the Signature smoke detector that is being installed. Also verify that duct air rela- tive humidity is within 0% and 93%. WARNING: Duct detectors have specific limitations. Duct detec- tors ARE NOT a substitute for an open area smoke detector. Duct detectors ARE NOT a substitute for early warning detection. Duct detectors ARE NOT a replacement for a building's regular fire detection system. Smoke detectors ARE NOT designed to detect toxic gases which can build up to hazardous levels in some fires. These devices WILL NOT operate without electrical power. As fires frequently cause power interruptions, EDWARDS suggests you discuss further safeguards with your local fire protection specialist. Installation and Mounting EDWARDS recommends duct detectors always be installed in ac- cordance with the latest recognized editions of local and national fire alarm codes. Typical Wiring The detector mounting bases and test station will accept #18 AWG (0.75mm2), #16 (1 .0mm2), #14 AWG (1 .50mm2) and #12 AWG (2.5 mm2) wire sizes. Note: #14 AWG (1.5 mm2) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page 2 of 4 Accessories Duct Detector Air Sampling Tubes One air sampling inlet tube must be ordered for each duct smoke detector housing. Refer to Ordering Information for available lengths. Detector Mounting Bases One detector mounting base must be ordered for each duct smoke housing. Removing a detector from its base (except isola- tor base) does not affect other devices operating on the same data loop. Available bases are: Standard Base SIGA-SB - This is the basic mounting base. The SIGA-LED Remote LED is \ supported by the Standard Base. tc- Relay Base SIGA-RB - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp @ 30 Vdc (pilot duty). The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if pro- grammed to do so at the control panel (EST3 V. 2 only). The Relay Base does not support the SIGA-LED Remote LED. Relay bases are not affected or activated by the SIGA-DTS Duct Test Station. Isolator Base SIGA-IB - This base includes a built-in line fault isolator. A detector must be installed for it to operate. The integral isolator relay is controlled by the detector or the loop controller. A maximum of 96 isolator bases can be installed on one loop. The Isolator Base does not support the SlGA-LED Remote LED. Alarm LED Indicator - The SIGA-LED Alarm Indicator is suitable for use with the SIGA-SB detector base only. A maximum of one can be operated for each detector. It features a red LED on a one-gang plastic plate and can be installed remote or directly on the SIGA-DH Duct Housing. Duct Test Station o ns1jo TheCSIGA-DTS_Duct Test Station uses a key switch along with an integral intelligent input module mounted on a two-gang plastic plate. It is supplied with two keys and features a red alarm LED. When the key is turned to the "TEST" position, the LED lights and the integral module remotely inputs a duct detector test alarm. The actions and sequences programmed at the control panel to activate dampers and other smoke control measures, are easily tested. Detector relay bases are not affected or activated. Resetting the control panel clears the test and returns the system to normal. The key cannot be removed when in the "TEST" position. The Duct Test Station mounts to standard 2-inch deep North American two-gang and 4-inch square electric boxes and Euro- pean 100 mm square boxes. Air Velocity Test Kit The 6263-SG Air Velocity Test Kit is specially designed to interface to the SIGA-DH Duct Housing. It is used to test or confirm the air velocity in HVAC ducts where the duct housing is installed. DATA SHEET E85001-0325 Not to be used for installation purposes. Issue 1 Specifications Compatible Smoke Detectors SIGA-PS SIGA-PHS SIGA-IPHS Ionization Photoelectric Photoelectric - Unipolar Photoelectric Smoke Sensing Element(s) - Light Scattering Principle - Light Scattering Principle Heat - - Light Scattering Principle Heat 135" F (57" C) Fixed Temperature - Alarms at 65" F (35" C) change in ambient temperature Air Velocity Range 300 to 4000 ft/mm. (1.5 to 20.3 m/sec) 300 to 1000 ft/mm. (1.5 to 5.0 m/sec) Temperature: 32 - 120" F (0 to Operating Environment 49" C) Temperature: 32 - 100" F (0 - 38" C) Humidity: 0 to 93% RH, Humidity: 0 to 93% RH, non-condensing non-condensing Storage Environment Temperature: -4 to 140" F (-20 to 60" C); Humidity: 0 to 93% RH, non-condensing ULl/ULC Sensitivity Range 0.67% to 3.77% obscuration/foot (305mm) 0.67% to 3.70% obscuration/foot (305mm) Dimensions 7-3/8 inches (188mm) W x 7 inches (178mm) H x 5 inches (127mm) D Material and Finish 16 Gauge Cold Rolled Steel, Red - Baked Enamel Conduit Knockouts Combination 1/2 inch & 3/4 inch Agency Approvals - UL, ULC, MEA, CSFM User Selected Sensitivity Settings Least Sensitive: 3.5%; Less Sensitive: 3.0%; Normal: 2.5%; More Sensitive: 2.0%; Most Sensitive: 1.0% Pre-alarm Sensitivity 5 % increments, allowing up to 20 pre-alarm settings Electrical, Physical Characteristics - Refer to individual detector catalog sheets Compatible Mounting Bases SlGA-SB Standard Base, SIGA-RB Relay Base, SIGMB Isolator Base Compatible Remote LED SIGA-LED (LED flashes when in alarm) Controller Compatibility SIGNATURE Loop Controller Addressing Restrictions Uses one Input Device Address Note: The SIGA-DH Duct Housing is not weatherproof or dust tight.) SIGA-DTS Duct Test Housing Operating Current iI4dp) Operating Voltage - 15.2 to 19.95 Vdc (19 Vdc nominal)• Replacement Key p/n - P-037449 Storage and Operating Temperature 32 to 1207 (0 to 49"C) Onboard LED Operation - Red LED - flashes when in alarm or test state Mounting North American electric box: 2 inch deep 2-gang or 4 inch square; European electric box: 100 mm square Construction & Finish High Impact Engineered Plastic 2-gang front plate - White Addressing Restrictions Uses one Module Address Page 3of4 DATA SHEET E850010325 Not to be used for installation purposes. Issue 1 Ordering Information Catalog Number Description Ship Wt lb. (kb) (rr (SiGA-Dl-J Duct Detector Housing 6.5 (3.0) LIFE SAFETY & INCIDENT MANAGEMENT Sampling Tubes 6261-001 8 inch (200mm) Air Sampling Inlet Tube 0.25 (0.1) Contact us... 6261-002 24 inch (600mm) Air Sampling Inlet Tube 0.5 (0.2) Email: edwards.fire@fs.utc.com 6261-003 42 inch (1060mm) Air Sampling Inlet Tube 1.6 (0.8) Web: Edwards-fire.com 6261-006 78 inch (1980mm) Air Sampling Inlet Tube 2.2 (1.0) 6261-010 120 inch (3048mm) Air Sampling Inlet Tube 4.4 (2.0) EDWARDS is a UTC brand. - 1016 Corporate Park Drive Compatible Detectors and Bases Mebane NC 27302 SlGA-lPHS 4D Multisensor Detector 0.5 (0.23) SlGA-PHS 3D Multisensor Detector 0.5 (0.23) @2016 United Technologies Corporation. SlGA-PS Photoelectric Detector 0.5 (0.23) All rights reserved. SlGA-SB Standard Base 0.2 (0.09) SIGA-RB Relay Base 0.2 (0.09) SIGA-113 Isolator Base 0.2 (0.09) Annunciation and Testing SIGA-LED Alarm LED Indicator 0.2 (.09) SiGA-DTSJ Duct Test Station 0.4 (.18) 6263-SG Duct Air Velocity Test Kit Page 4ot4 DATA SHEET E850010325 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. L3240-1657:01o18 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com - DESIGN: Models 6260(1)-100, 6265(1)-001/-002, 2435P, 1235B, A19863,[SlGA-D14) and 6260A-CU Duct Smoke Detector Units. Unit consists of a metal enclosure, relay, electrical components, a separately listed open area detector, a detector base and a sampling and exhaust tubes. Refer to listee's data sheet for additional detailed product description and operational considerations. (1): First four digits followed by an alpha suffix. RATING: 300-4000 fpm except for Model 6260B-100 is range from 4004000 fpm. Model SiGA-DH with Model SIGA-IPHS detector head, the sensitivity must be set at Levels 1 through 4 for velocities over 1000 fpm. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as duct smoke detector housing units for use with separately listed compatible control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 3240-1591:108, 3240-1388:104, 3240-0073:141, 3242-0073:141, 3240-0073:118 and 3241-0073:118 7-29-10 ma ØTI ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 0-1657:07 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Optional detector accessories: 5956; Remote Annunciator 6262-001 Key Switch 6254-003 Fire Alarm Relay 6254-001 Fire Alarm Power Supply 6256-200, C-DTS Fire Alarm /indicator/Testing Station SIGA-LED Remote LED Alarm Indicator IGA-DTS) Remote Test Station SIGA-DG Smoke Detector Guard SlGA-DGSB Smoke Detector Guard Surface Mount Box SIGA-DGMF Smoke Detector Guard Flange EC-LED Remote LED Alarm Indicator All prefixes may be followed by a alpha character between A and Z except C to classify a specific market. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as optional accessories. Intended for use with separately listed compatible detectors. Model SIGA-DG is intended for use only with Models SIGA-IPHS (CSFM Listing No. 7258-1657:123) and SIGA-PS (CSFM Listing No. 7272-1657:126) smoke detectors. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:127 and 7300-1388:191 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - • ._irb 1 14 LUUME I r iL now IN, L9 LN. 12, MAORI, Wpm Ui Ies EDWARDS Catalog Intelligent Input/Output LIFE SAFETY INCIDENT MANAGEMENT High Power Control Relay Module (SIGA-CRH) k: Description The SIGA-CRH High Power Control Relay Module is an address- able device designed for interface applications that require a high voltage, high current relay. Two identical sets of relay terminals are provided. Both sets of relay contacts transfer when the module is activated or restored. The state of the output terminals is not supervised. The module requires one address on the signaling line circuit (SLC). The address is assigned electronically. There are no ad- dress switches to set. Standard Features High Power Rating 120/240 VAC or 24 VDC rated contact can be used to control external appliances such as door closers, fans, dampers etc. Provides one relay with two Form C contacts Relay accepts 12 to 18 AWG (1.0 to 4.0 mm2) wiring from two sources Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Removable terminal blocks Easy wiring and module replacement. Electronic addressing Programmable addresses are downloaded from the loop con- troller or PC; there are no switches or dials to set. Intelligent device Distributed intelligence allows lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Page lof4 DATA SHEET E850010644 Not to be used for installation purposes. Issue 1 Application Personality code Use Personality Code 8 to configure the SIGA-CRH module: Personality code 8: Signal - dry contact output. Configures the module as a dry relay contact to control external appli- ances (door closers, fan controllers, dampers) or equipment shutdown. Indication The status LED shows the state of the module through the cover plate: Normal: Green LED flashes Alarm/active: Red LED flashes Compatibility The SIGA-CRH is part of the Signature Series intelligent process- ing and control platform. It is compatible with EST3, EST3X, and iO Series control panels. Warnings & Cautions The SIGA-CRH will not operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Testing & Maintenance SIGA-CRH automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing The loop controller electronically addresses the SIGA-CRH, saving valuable time during system commissioning. Setting complicated switches or dials is not required. The module has its own unique serial number stored in its on-board memory. Installation Compatible electrical box SIGA-CRH 0 Wall plate 0 ° Consult the SIGA-CRH High Power Control Relay Module Installa- tion Sheet for details. Wiring (i)ld ° ° ° II 0 I II 1 0 0 0 0 Signaling line circuit (SLC) from previous device Signaling line circuit (SLC) to next device Power-limited and supervised Normally closed contact (NC) Common contact (C) Normally open contact (NO) Relay terminal set 2. Not supervised. Power-limited unless connected to a nonpowerlimited source. If the source is nonpower-limited, eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm) space from power-limited wiring. For other mounting methods, see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring. The wire size must be capable of handling fault current from a nonpower-limited source. - or - Use type FPL, FPLR, FPLP, or permitted substitute cables, provided these power-limited cable conductors extending beyond the iacket are separated by a minimum of 0.25 in. (6.4 mm) space or by a nonconductive sleeve or nonconductive barrier from all other conductors. Refer to the NFPA 70 National Electrical Code for more details. (8) Relay terminal set 1. Identical to (7). Page 2of4 DATA SHEET E850010644 Not to be used for installation purposes. Issue 1 Specifications SLC operating voltage 15.20 to 19.95 VDC SLC current _______ Standb3) 75pAi ctivated) 75 pAmax.) Contact ratings [1][2] 240 V 50/60 Hz 7 A (PF 0.75), 1.5 A (PF 0.35) 120 V 50/60 Hz 7 A (PF 0.75), 3.0 A (PF 0.35) 24 VDC 6 A resistive Audio switching 0 to 20 kHz [3] Relay type 2 Form C, programmable Relay ready delay From power up 30 s max. (includes initial state set) From previous activation 5 s max. (one activation) 8 s max. (two activations, 1 s apart) Ordering Information Catalog Ship Weight Number Description lbs (kg) (IGA-C High Power Control Relay Module 0.4 (0.15) Circuit designation Signaling line circuits Relay circuits Number of SlGA-CRH per SLC Wire size Compatible electrical boxes Agency Listings Operating environment Temperature Relative humidity Storage temperature Class A, Style 6 or Class B, Style 4. Refer to the control panel technical publications for SLC wiring details. Class F 60 max. 12 to 18AWG (1.0 to 4.0 mm2) North American double-gang x 2-1/8 in. (54 mm) deep box North American standard 4 in. square x 2-1/8 in. (54 mm) deep box CAN/ULC-5527, UL 864 32 to 120°F (0 to 49°C) 0 to 93%, noncondensing -4 to 140°F (-20 to 60°C) [11 Provide external fusing and back-EMF mitigation as required by your application. Do not use the SIGA-CRH in a mixed application, where one set of relay terminals has high-power requirements and the other set carries a low-power signal, as this may result in physical contamination of the low-power signal contacts. [21 The minimum load required in order to avoid long-term contact oxidation is 100 mA and 12 V [3] Power must not exceed the contact ratings shown for a given PF (power factor). Page 3of4 DATA SHEET E850010644 Not to be used for installation purposes. Issue 1 bWAE DS (nnIn.rntnr1fl1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-firecom EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0644 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 73001657:0121 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SiGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SlGA-MCCI, SlGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SlGA-MPI, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-U102R, SIGA-U106 and SIGA-Ul06R motherboards. Model CS-SIGA-CC1P releasing module. Models SIGA-CCIS and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CT1 HT; Signature Series High Temperature Single Input Module. IGA-iHigh Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30,20K7) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog P Intelligent Input-Output I FA.00 - SM IL174 floIogies LIFE SAFETY INCIDENT MANAGEMENT Synchronization Output Module [S~IGA-CCis) MCC1S (I {:• i': Patented l®I ? MEA 7300657: 0121 S3424 [j Overview SIGA-CC1 S and MCC1 S Synchronization Output Modules are in- telligent analog addressable devices that form part of EDWARDS'S Signature line of products. The actual operation of the SlGA-CC1 S and MCC S is determined by the "personality code" selected by the installer, which is downloaded to the module from the Signa- ture loop controller during system configuration. Depending on their assigned personality, Synchronization Output Modules may be used as a signal power riser selector to provide synchronization of fire alarm Signals across multiple zones, or for connecting, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to operate au- dible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter's telephones. Standard Features Provides UL 1971-compliant auto-sync output for visual signals Use for connecting a supervised output circuit to a supervised 24 Vdc riser input and synchronizing multiple notification appli- ance circuits. Functions as an audible signal riser selector Use as a synch module or for connecting supervised 24 Vdc Audible/Visible signal circuits, or 25 and 70 VRMS Audio Evacuation and Telephone circuits to their power inputs. Built-in ring-tone generator When configured for telephone circuits, the SIGA-CC1 S gener- ates its own ring-tone signal, eliminating the need for a sepa- rate ring-tone circuit. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Page 1 014 DATA SHEET E85001-0543 Not to be used for installation purposes. Issue 1 Application The StGA-CC1S mounts to a standard North American two-gang electrical box, making it ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-MCCIS is part of the UIO family of plug-in Signature Series modules. It functions identically to the SlGA-CC1S, but takes advantage of the modular flexibility and easy installation that characterize all UIO modules. Two- and six-module UIO mother- boards are available. These can accommodate individual risers for each on-board module, or risers that are shared by any combina- tion of its UIO modules. All wiring connections are made to termi- nal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Personality Codes The operation of the SIGA-CC1 S is determined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. Personality Code 5: Signal Power or Audio Evacuation (sin- gle riser). Configures the module for use as a Class B Audible! Visible Signal power (24 Vdc polarized) or Audio Evacuation (25 or 70 VRMS) power selector. The ring-tone generator is disabled. The output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/ visible signal circuit to prevent connection to the power circuit. Personality Code 6: Telephone with ring-tone (single riser). Configures the module for use as a Telephone power selector. When a telephone handset is plugged into its jack or lifted from its hook, the module generates its own Ring-Tone signal. A separate ring-tone circuit is not needed. The module sends this signal to the control panel to indicate that an off-hook condition is present. When the system operator responds to the call, the ring-tone signal is disabled. Personality Code 25: Visual Signal Synchronization. This personality code configures the module to provide synchronization of fire alarm signals across multiple zones. It functions as a signal power (24 Vdc) riser selector. The output wiring is monitored for open circuits and short circuits. A short circuit will cause the fire alarm control panel to inhibit the activation of the audible/visual signal circuit so the riser is not connected to the wiring fault. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. EDWARDS recommends that these modules be installed accord- ing to latest recognized edition of national and local fire alarm codes. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Installation The SlGA-CC1S: mounts to North American 2-1/2 inch (64 mm) deep 2-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with 2-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. SIGA-MCC1S: mount the UIOxR motherboard inside a suitable EDWARDS enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlOxR motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mml wire size. UIO Motherboard 6-32 Self-tapping / screws Plug-in ~(UIO) >Captive Module screws #6 Flat washers '—Cabinet or electrical enclosure Electronic Addressing The loop controller electronically addresses each module saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its "on-board memory". The loop control- ler identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other perti- nent messages. Single modules may be turned off (de-activated) temporarily, from the control panel. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Page 2 of 4 DATA SHEET E85001-0543 Not to be used for installation purposes. Issue 1 Typical Wiring SIGA-CCIS (Standard Mount) Code UL/lJLC Listed Personality Typical Speaker Circuit 47KW EOL Personality Typical Telephone Circuit Code 6 ul/uLc Listed [111111111 iIC]In 471541 EOL Personality Enhanced Integrity and Genesis Devices Code 25 UL/ULC Listed 47KW (01 109 cc's 00 Riser Out 1+1 I I I I To next device Riser out I-I Riser in 1+1 0From control ponei To next device or EOL cesis Data out (-I Data out (+1 Riser in I-I I Data in 1+1 1 From Signature Controller I Data in I-I or Previous Device SIGA-MCCIS (UIO Mount) Code S UIJULC Listed DF) 38 Personality Typical Speaker Circuit 47KWEOL Personality Typical Telephone Circuit Code 6 UULC Listed 47KW (01 1xM Personality Enhanced Integrity and Genesis Devices Code 25 ULIULC Listed F-6V`~S7KWEOL 1210 UIOIRI series motherboard Dototn Riser lOut I signoture] • Riser I In Data 3 rein Circuit +Jl TO? ootoOut 5J U Green LEO lNorrnoll Red LED lActivel TBIS : 1234 Riser 1IntJ LL; Riser lout Multiple CCI(S) modules using the BPS's sense inputs NAC1/ + AUX1 - NAC2/ + AUX2 - NAC3/ + A UX3 - NAC4/+ AUX4 - 200 mAAUX Continuous Sense 1 COMII OUTE IN Sense 2COMEj OUT NO Trouble COM NC o TB1 Notification appliance circuit (NAC) UL listed EOL 15 KIN Notification appliance circuit (NAC) UL listed EOL 15KW - EOL47K II I +1 — - — - lN t Iff -EOL 47K -11•'•___ II ________ II ______________ 1O9 1 CC1(S)mod 109 CC1(S)module 0-o_- TB2 [3] Page 3 of 4 DATA SHEET E85001-0543 Not to be used for installation purposes. Issue 1 1.1FF SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CCIS SIGA-MCC1S North American 21/2 inch (64 mm) deep two-gang boxes and 11/2 Plugs into U102R, UI06R or U106 Mounting inch (38 mm) deep 4 inch square Motherboards boxes with 2-gang covers and SIGA-MP mounting plates Description Synchronization Output Module Type Code 50 (factory set) Address Requirements Uses one module address Wiring Terminations Suitable for #12 to #18 AWG (2.5 mm2 to 0.75mm2) perating Cuffe Sidby = 223pA (Acvated=1OOp Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) 24 Vdc = 2 amps Output Rating 25 V Audio = 50 watts 70 V Audio = 35 watts Construction High Impact Engineering Polymer Storage and Operating Operating: 32°F to 120°F (0°C to 49°C) Environment Storage: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation Green LED - Flashes when polled Red LED - Flashes when in alarm! active Compatibility Use with: Signature Loop Controller under EST3 version 2.0 or higher Agency Listings UL, ULC, CSFM, MEA Ordering Information Catalog Description . Shipping Wt. Number . lbs (kg) (SlGA-CCj) Synchronization Output Module (Standard Mount) - UL/ULC Listed 0.5 (0.23) SIGA- MCC1 Synchronization Output Module (UIO Mount) - UL/ULC Listed 0.18 (0.08) Related Equipment 27193-21 Surface Mount Box - Red, 2-gang 2(1.2) 27193-26 Surface Mount Box - White, 2-gang 2 (1.2) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32(0.15) Universal Input-Output Module Board w/Riser Inputs SIGA-UlO6R 0.62 (0.28) - Six Module Positions SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) 235196P Bi-polar Transient Protector 0.01 (0.05) MFC-A 7.0(3.1) supports Signature Module Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Sionature Module Mountina Plate. 1/2 footorint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4 of 4 DATA SHEET E85001-0543 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1657011 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CTI, SIGA-CT1 HT, SlGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SlGA-MCCI, SIGA-MCC2, SIGA-MCR and SlGA-MCRR remote transponders. Models SlGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MPI, SlGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UIO2R, SIGA-U106 and SIGA-U106R motherboards. Model CS-SlGA-CCIP releasing module. Models' SIGA-CC1S_'and SlGA-MCC1 S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SlGA-CR2 Control Relay Module. Model SlGA-CTI HT; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division WE III mirk Zwoll FJMR ME, qmn EDWARDS Catalog Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Field Configurable '0 1 k-. Ceiling Strobes Genesis Series IX, F:IRE RT One or more patents pending. \ FC 1.0 I®I MEA C E 7125-1657: 0219 55389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLJght technology. FullUght strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - idea] for long runs or existing wiring Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - ULJULC listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 2118' (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8" dia. I (173 mm) _\ I 1.0" (25 mm) —/ 0.60(15 mm) Light output (effective cd) Percent of UL rating versus angle Percentage of rated output - 0• Anglë— Hortzontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output - Candela switch (see ordering information). The output / setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. / The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices will not operatewithout electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 90• '5. f4 To listed To next fire alarm I l ___ I r ___appliance, control Il ll I end-of-line panel or return to + I control I equipment Page 2ot4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Light output setting, standard models UL 1 95" or "D" or fl75I or 949591 or "A" Rating RMS RMS RMS RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 Typical Light output setting, standard models "15" or "D" 1630" or "C" "75" or "B" "95" or "A" Current RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 24Vd L63) (90j, 1194i 33 Vdc 48 70 124 139 16Vtwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Light output setting, high output models "95" or "D" "115" or "C" "150" or "B" "177" or "A" RMS RMS RMS RMS 330 392 502 565 432 518 643 693 Light output setting, high output models 6195" or "D" "115" or "C" "150" or "B" "177" or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models g available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Ooeratinci environment Indoor: 321200 F (0-49° Cl ambient temoerature: 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC 5524-01. AJI models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 Cd (GC-VM) and 95/115/150/177 cd (GC-VMH) GC-VM series strobes: non-coded, filtered 16-33 Vdc Strobe operating voltage or unfiltered 16-33 Vdc RNR. GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. - SIGA-CC1S, SlGA-MCC1S, SlGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, i064, i0500, Fireshield Plus 3,5 and 10 zone. Add Gi M for G1-CVM &G1 -HDVM devices only. Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 LIFE SAFETY 8 INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Model I Housing I Marking I Lens I Strobe I Ship Wt Life safety Aooliances Ic/w runnina man icon screen orinted on housinal GC-VM White None Clear Selectable 15, 30, 75, 0r95 cd 181b (0.82 kg.) CF-\iM White FIRE" GCFR-VM Red FIRE' GC-VMH White None Selectable high output 95, 115, 150, or 177 ad GCF-VMH White "FIRE" ECS/MNS Aooliances (no runnina man icon on housinall GCWA-VMA White "Alert" Amber Selectable A. B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Al" ert Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. Page 4of4 DATA SHEET' E85001-0557 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125-1657:0219 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM,(GCF-VM GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model GIM-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017D Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division L 0 M 1101M,11; IVE! N__ ArA.1 F. t it!Iies EDWARIDS Catalog Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Field Configurable, -_ One or more patents pending. Ceiling Horn -Strobes Genesis Series Overview ' FC 7300. 1657: IVIEA 0202 S218 Standard Features Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullUght strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FuilLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for Jong runs or existing wir- ing Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page lot 4 DATA SHEET E85001-0559 Not to be Used for installation purposes. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Polarity: alarm c next )liance, I-of-line etum to ontrol iipment Note: Strobes must have continuous voltage. (173 mm) ' O6O(15 mm) Page 2 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 Cd 150 cd 177 cd RMS RMS RMS RMS 341 399 506 570 487 578 670 711 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd RMS Mean 115 cd RMS Mean 150 cd RMS Mean 177 cd RMS Mean 324 322 377 374 477 474 554 551 258 256 299 296 369 366 417 414 220 217 252 249 304 301 341 338 172 169 188 185 223 220 244 241 463 265 535 312 665 400 718 442 392 211 439 240 517 287 587 334 346 179 382 212 458 246 498 271 296 142 323 152 358 178 387 194 GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting 95 cd 115 Cd 150 cd 177 Cd RMS Mean RMS Mean RMS Mean RMS Mean 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 432 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 High dB - Setting UL464 Average Peak Temporal Steady Temporal/ Steady Temporal/ Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 1 95.7 1 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal/ Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 1 80.9 85.9 91.8 95.1 Percent of UL rating versus angle PC.,fULRng 90• Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting r UL l5cd 30cd 75 cd 95 cd Rating RMS RMS RMS RMS 16 Vdc 147 190 316 372 16Vfwr 189 253 417 451 GC-HDVM Temporal Horn-strobe: High dB Setting Typical l5 cd 30 cd 75 cd 95cd Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 - 276 333 328 20 Vdc 91 80 124 117 219 214 257 251 (24vd) W0,1 (1) (ö ö) (1 K)' (180) 33 Vdc 69 62 89 84 144 140 160 156 16Vfwr 153 81 218 123 388 240 420 268 20Vfwr 141 70 190 100 325 188 378 219 24Vfwr 135 64 176 90 280 154 310 180 33Vfwr 139 61 167 80 241 122 254 133 GC-HDVM Temporal Horn-strobe: Low dB Setting f'picai 15 cd 36 cd 75cd S6 cd Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 181 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for fitered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output Light output — (effective cd) Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room: 3. Average and Peak values are measured in ànechoic cham- ber. Page 3of4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 @2016 United Technologies Corporation. All rights reserved. Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rrdng. Red and white models available. Lens Optical grade polycarbonate (clear) Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-S526, year 2004 UL Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone ham-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources Gi M-RM, SlGA-CC1 5, SIGA-MCC1 5, BPS6A, BPS1 OA GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) ½ sec: ON, ½ sec OFF, ½ sec ON, ½secOFF, ½ sec ON, 11/2 sec Temporal audible pattern OFF, then repeat cycle Ordering Information Catalog Housing Ship Number Color Marking Description Wt. lbs (kg) GC-HDVM White None (GCFHDV.M White "FIRE" Genesis Ceiling/Wall Horn-Strobe with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red "FIRE" (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories G1 M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 (011) SlGA-CC1 S Intelligent Synchronization Output Module (2-gang) 3) SIGA-MCC1 S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with FIRE" marking. Page 4014 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125-1657:0202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST' GI-HVI5, -HV30, -HV60, -HV-75, GI-HOVI5, -HOV30, -HOV60, -H0V75, -HOV1I0, GIF-HOVI5, -HOV30, -HOV60, -H0V75, -HOVI10, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV1I0, G1-HDVM, G1R-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH,(GCF-HDVM GCFR-HDVM, GCF-HDVMH, G1-HDV1575, GI R-HDV1575, GIF-HDV1575, and GIRF-HDV1575 horn/strobes with or without suffixes -Rand -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33VdcNfwr - Models GI-HDVM, GIR-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, GI R-HDV1575, GI F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, GI R-HDV1575, Gi F-HDV1575, GI RE-H DVI 575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SIGNALING LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information FAD ACE-11 The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 41313 USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. [7 ISO9,091 ~D 241-M-1 1AFAMS Space Age Electronics, Inc. REGISTERE/D www.l~ae.com NFPA COMPANY 800.486.1723 Toll Free Made 508.485.0966 Local rrn r r 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! /,----JS PACE AGE /ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector ' Property Information Minimum Roq,red Dorn,,,flttion (SIG-FUN) — - - Key Ring -. .--.. .. Hooks Carfificaflam, and Approval - 16.1 SystemflWIIntiO1 COflS,CtOr iF • flSI,*Thfl..MdIttbdd - __._.._*.___.__ Business Card Holder 'i - j• I' ---- -- Equipment Inf,,,tIo - — - Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.1sae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # E00479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. C7300-0553:01 10 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFXIA and IFXID enclosures. ModelsACE-11) ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division