5919 SEA OTTER PL; 100; FPC2018-0024; Permit
4ity of Carlsbad Print Date: 10/24/2024 Permit No: FPC2018-0024 Job Address: 5919 SEA OTTER PL, # 100, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel t: 2090820900 Valuation: $3,799,448.41 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 01/22/2018 Issued: 02/07/2018 Finaled Close Out: 04/08/2021 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: NORTEK - PRE-ACTION RELEASE PANEL IN SERVER ROOM (3 SPRINKLERS) Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JOHN MOCKER 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov fPcZoi S -OOL4 MRP-2001 (E) Deluge - Preaction Control Panel General The MRP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001 is compatible with System Sensor's detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire'Lite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appli- ance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2001 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm infor- mation on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2001E offers the same features as the MRP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels. Features Listed to UL Standard 864, 9th edition. FM Approved. Designed for sprinkler standards NFPA 13, 15 and 16. Dual hazard operation. Adjustable waterflow, discharge timer and two soak timers. Cross-zone (double-interlock) capability. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). System Sensor i3 series detectors compatible. Four programmable Style Y (Class B) output circuits - (spe- cial application power). Strobe Synchronization: - System Sensor - Wheelock - Gentex - Faraday - Amseco Three programmable Form-C relays. 7.0 amps total 24 VDC output current. Resettable and non-resettable output power. DF-60237:C1 • A2-300 (a Fure•LITeALarms by Honeywell Built-in Programmer. ANN-BUS for connection to optional devices (up to 8 total of any of the following): - ANN-80 Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module 80-character LCD display (backlit). Real-time clock/calendar with daylight savings time control. History log with 256 event storage. Piezo sounder for alarm, trouble and supervisory. 24 volt DC operation. Low AC voltage sense. Outputs Programmable for: - Releasing circuits or NACS NACs programmable for: - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder Disable/Enable control per input zone and output zone. Extensive transient protection. Automatic battery charger with charger supervision. Optional Dress Panel DP-51050 (red). Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet. Optional CAC-5X Class A Converter Module for Outputs and lDCs. DF-60237:C1 • 12/18/12 - Page 1 of 4 Standby Current: 4 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Notification Appliance and Releasing Circuit(s) - TB5 and TB7 Four Output Circuits. Style V (Class B) or Style Z (Class A) with optional con- verter module. Special Application power. Supervised and power-limited circuitry. Normal Operating Voltage: Nominal 24 VDC. Maximum Signaling Current: 7.0 amps (3.0 amps maxi- mum per NAC). End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Max. Wiring Voltage Drop: 2 VDC. Refer to the Fire.LiteDevice Compatibility Document for com- patible listed devices. Form-C Relays - Programmable - TB8 Relay 1 (factory default programmed as Alarm Relay). Relay 2 (factory default programmed as fail-safe Trouble Relay). Relay 3 (factory default programmed as Supervisory Relay). Relay Contact Ratings: —2 amps @ 30 VDC (resistive) - 0.5 amps @ 30 VAC (resistive) Auxiliary Trouble Input - J6 The Auxiliary Trouble Input is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector cir- cuits. Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors (see note 1). Power-limited Circuitry. Refer to the Fire.Lite Device Compatibility Document for com- patible listed devices. NOTE: 1. Total current for reseltable power, nonresettable power and Output Circuits must not exceed 7.0 amps. Special Application Resettable or Nonresettable Power - 189 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA (see note 1). Power-limited Circuitry. Jumper selectable by JP31 for resettable or nonresettable power. Refer to the Fire•Lite Device Compatibility Document for com- patible listed devices. Alarm Zones 1 - 5 on T134. Alarm Zone 6 on TB6. Supervised and power-limited circuitry. Style B (Class B) wiring with Style D (Class A) option. Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 Ohms. End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Page 2 of 4— DF-60237:C1 • 12/18/12 Optional 4XTMF Municipal Box Transmitter Module. Optional Digital Alarm Communicators (411, 411UD, 411 UDAC). PROGRAMMING AND SOFTWARE: Custom English labels (per point) may be manually entered or selected from an internal library file. Three programmable Form-C relay outputs. Pre-programmed and custom application templates. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. USER INTERFACE: Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. ANN-Bus for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) DISCHARGE (red) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL AC Power - TB1 MRP-2001: 120 VAC, 60 Hz, 3.66 amps. MRP-2001 E: 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum #14 AWG (2.0 mm2) with 600V insula- tion. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp. Supervised, nonpower-limited. Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55). Minimum Battery Size: 7 Amp Hour. Initiating Device Circuits - TB4 and TB6 Product Line Information MRP-2001: Six-zone, 24 volt Deluge-Preaction Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard deluge and preaction applications. MRP-2001E: Same as above but allows connection to 240 VAC. NOTE: For ULC-listed model, see DF-60441. CAC-5X: Class A Converter Module can be used to convert the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style V (Class B) Output Circuits to Style Z (Class A). NOTE: Two Class A Converter modules are required to convert all four Output Circuits and six Initiating Device Circuits. 4XTMF: Transmitter Module provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is unshielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside or out- side the cabinet, provides 10 programmable Form-C relays. (See DF-52431.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) DP-51050: Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allow- ing access to the membrane switch panel. TR-CE: Trim-ring (red) is available as an option. The trim-ring allows semi-flushing mounting of the cabinet. BB-26: Battery box, holds up to two 26 Amp Hour batteries and CHG-75. BB-55: Battery box, houses two 55 Amp Hour batteries. BAT Series Batteries: Refer to DF-52397. PRN-6F: UL-listed compatible event printer. Dot-matrix, trac- tor-fed paper, 120 VAC. PRT-PK CABLE: Programming cable. Used to update the FACP5 Flash firmware. (Also requires an RS485 to R5232 converter). DF-60237V • 12/18/12 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Annunciators .8 Electrical Specifications MRP-2001 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps. MRP-2001E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring (TA- CE): 22.00' (55.88 cm.) high x 19.65' (49.91 cm.) wide. Shipping Specifications Dimensions: - Height 20.00' (50.80cm) - Width 22.50' (57.15cm) - Depth 8.50' (21.59cm) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 271C/60 - 80°F NFPA Standards The MRP-2001(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - NFPA 13 Installation of Sprinkler Systems - NFPA 15 Water Spray Fixed Systems - NFPA 16 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems - NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) Agency Listings and Approvals The listings and approvals below apply to the basic MAP- 2001(E) and MRP-2001(E)E fire alarm control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL: S624 FM approved CSFM: 7165-0075:0216 MEA: 333-07-F NOTE: For ULC-listed model, see DF-60441. FlreLlte® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-60237:CI • 12/18/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0216 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models MRP-2001, MRP-2001 E, MRP-2002, and MRP-2002E conventional fire alarm control unit. Each unit employ six programmable input circuits, four programmable output circuits, and three relay contact outputs for alarm, trouble, and supervisory signals. These units do not contain an integral digital alarm communicator transmitter (DACT). The °E" suffix represents 240 V ac 50 Hz rated units. Models MRP-2001 and MRP-2001 E are intended for water release, deluge, and pre-action control. Models MRP-2002 and MRP-2002E are intended for agent release control. FLPS-7 Power Supply module 4XTMF Transmitter module CAC-5X Converter module ANN-80 LCD Annunciator ANN-I /0 LED Driver module ANN-LED Annunciator module ANN-RLY Relay module ANN-S / PG Serial/Parallel printer module DP-51050 Dress panel DP-5105OLED Dress panel RATING: INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use as a pre action, deluge and agent releasing panel. Units also provide fire detection, signaling and protection features. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 08-07-07 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52521 :B1 • F-505 P Series Photoelectric Smoke Detectors General System Sensor's i3TM Series photoelectric and photoelectric/ thermal smoke detectors represent a significant advancement in conventional detection, incorporating three key features: installation ease, intelligence, and instant inspection. Installation ease. The i3 Series redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire-entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of backbox mounting methods, as well as direct mounting with drywall anchors. To complete the installation, i3 Series heads plug into the base with a simple Stop-Drop 'N LockTm action. Intelligence. i3 Series detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensa- tion and smoothing algorithms, to minimize nuisance alarms, are standard in the P Series. When connected to the 2W-MOD loop test/maintenance module, two-wire P detectors are capa- ble of generating a remote maintenance signal when they need cleaning. This signal is indicated by LEDs located at the module and at the panel. To read the sensitivity of j3 detectors, the SENS-RDR is a wireless device that displays sensitivity in terms of percent-per-foot obscuration. Instant inspection. The P Series provides wide-angle red and green LED indicators for instant inspection of detector condi- tion. The LEDs indicate: normal standby, out-of-sensitivity, alarm, or freeze trouble conditions. The "EZ Walk" loop test feature is available on two-wire P Series detectors when con- nected to the 2W-MOD loop test/maintenance module. The "EZ Walk" feature verifies the initiating loop wiring by providing LED status indication at each detector. Features Plug-in detector line - mounting base included Large wire-entry port. In-line terminals with SEMS screws. Mounts to octagonal and single-gang backboxes, 4" (101.6 mm) square backboxes, or directly to ceiling. Stop-Drop 'N Lock attachment to base. Removable detector cover and chamber for easy cleaning. Built-in remote maintenance signaling. Drift compensation and smoothing algorithms. Simplified sensitivity measurement. Wide-angle, dual-color LED indication. Loop testing via "EZ Walk" feature. Built-in test switch. Specifications PHYSICAL SPECIFICATIONS Operating Temperature Range: For models 2W-B and 4W-B: 32°F to 120°F (0°C to 490C); for thermal models 2WT-6 and 4WT-B: 32°F to 100°F (0°C to 37.8°C). Operating Humidity Range: 0% - 95% RH, non-condensing. Thermal Sensor: 135°F (57.2°C) fixed (models 2WT-B, 4WT-B). F1reLuTeALarms by Honeywell Freeze Trouble: 41°F (5°C) (models 2WT-B and 4WT-B). Sensitivity: 2.5%/foot (0.762%/meter) nominal. Input Terminals: Utilize 14 to 22 AWG wire. Dimensions (including base): 5.3" (134.62 mm) diameter, 2.0" inches (50.8 mm) high. Weight: 6.3 oz. (178.6 grams). Mounting Options: 3.5" (88.9 mm) octagonal backbox; 4" (101.6 mm) octagonal backbox; single-gang backbox; 4" (101.6 mm) square backbox with a plaster ring; or direct mount to ceiling. ELECTRICAL SPECIFICATIONS Operating Voltage: 12/24 V non-polarized nominal; 8.5 V minimum; 35 V maximum. Maximum Alarm Current" For two-wire models: 130 mA lim- ited by control panel; For four-wire models: 20 mA © 12 V, 23 mA © 24 V. Alarm Contact Ratings: For four-wire models: 0.5 A © 30 VACNDC; not applicable for two-wire models. LED Modes Green LED Red LED Power Up Blink ever, 10 sec- onds Blink every 10 sec- onds Normal (Standby) Blink every 5 sec- onds OFF Out of Sensitivity OFF Blink every 5 sec- onds Freeze Trouble OFF Blink every 10 sec- onds Alarm OFF Solid ON Power Up Sequence for LED Indication Condition Duration Initial LED Status Indication 80 Seconds DF-52521:131 .4/13/2012—Page 1 of 2 Architectural/Engineering Specifications Smoke detector shall be a System Sensor j3 Series model number , Listed to Underwriters Laboratories UL 268 Fire Protection Signaling Systems. The detector shall be a photoelectric type (models 2W-B, 4W-B) or a combination pho- toelectric/thermal (models 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.20C). The detector shall include a mounting base for mounting to 3.5 (88.9 mm) and 4" (101.6 mm) octag- onal, single-gang, and 4' (101.6 mm) square backboxes with a plaster ring, or directly mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.50/o/foot (0.762%/meter) as measured in the UL smoke box. The detector shall be capable of auto- matically adjusting its sensitivity by means of drift compensa- tion and smoothing algorithms. The detector shall provide dual-color LED indication which blinks to indicate power-up, normal standby, out-of-sensitivity, alarm, and freeze trouble (models 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD module, two-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capa- bility to verify the circuit without testing each detector individu- ally. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S911 FM Approved CSFM: 7272-1653:152 MEA: 290-01-E Maryland State Fire Marshal: Permit # 2093 Product Line Information 2W-B: Two-wire photoelectric smoke detector. C211111-BA: Same as 2W-B, ULC listing. 2WT-B: Two-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C2WT.BA: Same as 2WT-B, ULC listing. 4W-B: Four-wire photoelectric smoke detector. C4W-BA: Same as 4W-B, ULC listing. 4WTB: Four-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C4WT-BA: Same as 4WT-B, ULC listing. ACCESSORIES: 2W-MOD2: Two-wire loop test/maintenance module. SENS-RDR: Sensitivity reader. A77-AB2: Retrofit adapter bracket, 6.6" (167.7cm) diameter FlreLlte® Alarms® is a registered trademark and 13T14 and Stop-Drop 'N Lock are trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ffi1?1NUMVI1MT1RIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52521 :BI • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4W-r-B photoelectric type smoke detectors. Models 2W-B and 2W1-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2W1-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listees printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division