HomeMy WebLinkAbout5919 SEA OTTER PL; 100; FPC2018-0009; Permit4 City of PERMIT REPORT Carlsbad Print Date: 10/24/2024 Permit No: FPC2018-0009 Job Address: 5919 SEA OTTER P1, # 100, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel : 2090820900 Track U: Applied: 01/09/2018 Valuation: $3,799,448.41 Lot U: Issued: 01/17/2018 Occupancy Group: Project U: Finaled Close Out: 04/08/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Wong, Cindy Plan Check U: Fieri, Dominic Workman, Carisa Project Title: Description: NORTEK OFFICE TO OFFICE-.SPRINKLER > 100 (442 HEADS) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $198.00 FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE NFPA 13 or 13R System > 100 heads $634.00 Total Fees: $964.00 Total Payments To Date: $964.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov - - Fire Protection by Computer Design Cosco Fire Protection, Inc 4990 Greencraig Lane San Diego, CA 92123 858-444-2000 Job Name : Nortek ECOH System 2 Building : Suite #100 Location : 5919 Sea Otter Place System : 2 Contract : 10.CA_5385 Data File : Nortek ECOH - 16x16 System 2.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Cosco Fire Protection, Inc Page 1 Nortek ECOH System 2 Date 1-26-18 Hydraulic Design Information Sheet Name - Nortek - T.I. Date - 01-26-18 Location - 5919 Sea Otter Place Building - Suite #100 System No. - 2 Contractor - Cosco Fire Protection, inc. Contract No. - 10.CA 5385 Calculated By - M. Lovely Drawing No. - FP-202 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 14' Occupancy - Ordinary Hazard - Room #177 PIR/Flex Open S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 2500 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make Viking D Area Per Sprinkler - 256 ( ) Dry Model VK572 E Elevation at Highest Outlet - 14 ( ) Deluge Size 3/4 S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 14.0 I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 500 N Note Calculation Flow Required - 1116.29 Press Required - 93.462 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-01-17 Cap. - T Time of Test - N/A Rated Cap.- Elev.- E Static Press - 126 @ Press - R Residual Press - 113 Elev. - Well Flow - 3425 Proof Flow S Elevation - -3 U P Location - North End of Sea Otter Place - Hydrant H20747 P L Source of Information - City of Carlsbad Y C Commodity General Storage Class Location O Storage Ht. 8 Area Aisle W. M Storage Method: Solid Piled Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf - O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cosco Fire Protection, Inc Page 2 Nortek ECOH System 2 Date 1-26-18 City Water Supply: Demand: Cl - Static Pressure : 113.4 Dl - Elevation : 7.363 C2 - Residual Pressure: 100.4 D2 - System Flow : 616.29 C2 - Residual Flow : 3425 D2 - System Pressure : 93.462 Hose ( Demand) : 500 D3 - System Demand :1116.29 Safety Margin : 18.304 150 140 130 p120 C1 R 110 - C2 "-' E 100 - s 90 03 S 80 u 70 R6° E5° 40 30 20 I.I I I 10 Dl I I I 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW( N ' 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cosco Fire Protection, Inc Page 3 Nortek ECOH System 2 Date 1-26-18 Fitting Legend Abbrev. Name 1/2 % 1 11/4 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Cosco Fire Protection, Inc Page 4 Nortek ECOH System 2 Date 1-26-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 43.76 0.15 130 7.8 40.4 0.15 130 7.8 39.54 0.15 130 7.8 39.55 0.15 130 7.8 40.81 0.15 130 7.8 43.85 0.15 130 7.8 40.16 0.15 130 7.8 39.1 0.15 130 7.8 39.1 0.15 130 7.8 40.12 0.15 130 7.8 45.16 0.15 130 7.8 41.59 0.15 130 7.8 40.64 0.15 130 7.8 40.65 0.15 130 7.8 41.86 0.15 130 7.8 14.0 14 9.77 na 14.0 14 8.33 na 14.0 14 7.97 na 14.0 14 7.98 na 14.0 14 8.5 na 14.0 14 9.81 na 14.0 14 8.23 na 14.0 14 7.8 na 14.0 14 7.8 na 14.0 14 8.21 na 14.0 14 10.41 na 14.0 14 8.83 na 14.0 14 8.43 na 14.0 14 8.43 na 14.0 14 8.94 na 21.75 18.04 na 21.75 15.0 na 21.75 14.26 na 21.75 14.27 na 21.75 18.13 na 21.75 14.8 na 21.75 13.89 na 21.75 13.89 na 21.75 19.38 na 21.75 16.06 na 21.75 15.22 na 21.75 15.22 na 21.75 15.37 na 21.75 14.77 na 21.75 16.3 na 20.0 30.28 na 20.0 30.98 na 20.0 32.11 / na 20.0 34.54 na 20.0 36.41 na 20.0 37.86 na 20.0 38.99 na 20.0 39.9 na 20.0 40.64 na 20.0 41.25 na 20.0 41.78 na 20.0 42.24 na 20.0 42.66 na 20.0 43.03 na 20.0 43.39 na 20.0 43.71 na 20.0 44.02 na 20.0 44.3 na 20.0 44.56 na 20.0 45.0 na 20.0 41.07 na 20.0 41.09 na 20.0 41.15 na 20.0 41.27 na 20.0 41.44 na 20.0 41.65 na 20.0 41.9 na 20.0 42.19 na 20.0 42.5 na 20.0 42.82 na 20.0 43.15 na 20.0 43.47 na Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Cosco Fire Protection, Inc Page 5 Nortek ECOH System 2 Date 1-26-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. C13 20.0 43.79 na C14 20.0 44.1 na C15 20.0 44.39 na C16 20.0 44.66 na C17 20.0 45.36 na Bi 20.0 29.88 na B3 20.0 30.46 na Fl 20.0 31.92 na F2 20.0 32.13 na F3 20.0 32.23 na F4 20.0 32.79 na F5 20.0 33.8 na F6 20.0 35.99 na F7 20.0 37.61 na F8 20.0 38.83 na F9 20.0 39.77 na FIO 20.0 40.51 na Fli 20.0 41.11 na F12 20.0 41.62 na F13 20.0 42.06 na F14 20.0 42.47 na F15 20.0 42.86 na F16 20.0 43.26 na F17 20.0 43.71 na F18 20.0 44.21 na F19 20.0 44.79 na F20 20.0 45.49 na F21 20.0 46.35 na F22 20.0 48.48 na TOR 20.0 51.96 na BOR 2.0 61.2 na UG1 -3.0 65.29 na UG6 3.0 73.1 na BFI 3.0 74.59 na BF2 -3.0 85.74 na UG7 -3.0 87.23 na UG8 -3.0 93.27 na SCR -3.0 93.46 na The maximum velocity is 19.65 and it occurs in the pipe between nodes 11 and B5 Computer Programs by Hydratec Inc. Revision: 50.52.1 500.0 Final Calculations - Hazen-Williams - 2007 Cosco Fire Protection, Inc Page 6 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 51 43.76 1.049 T 5.0 12.000 9.769 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 1 43.76 0.5539 0.0 21.000 11.632 Vel = 16.24 0.0 43.76 18.044 KFactor= 10.30 S2 40.40 1.049 T 5.0 12.000 8.326 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 2 40.4 0.4778 0.0 21.000 10.034 Vel = 15.00 0.0 40.40 15.003 K Factor = 10.43 S3 39.54 1.049 T 5.0 12.000 7.975 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 3 39.54 0.4591 0.0 21.000 9.642 Vel = 14.68 0.0 39.54 14.260 K Factor= 10.47 S4 39.55 1.049 T 5.0 12.000 7.979 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 4 39.55 0.4594 0.0 21.000 9.647 Vel = 14.68 0.0 39.55 14.269 KFactor= 10.47 S5 40.81 1.049 T 5.0 12.000 8.498 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 5 40.81 0.4869 0.0 21.000 10.224 Vel = 15.15 0.0 40.81 15.365 KFactor 10.41 S6 43.85 1.049 T 5.0 12.000 9.811 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 6 43.85 0.5561 0.0 21.000 11.679 Vel = 16.28 0.0 43.85 18.133 K Factor = 10.30 S7 40.16 1.049 T 5.0 12.000 8.230 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 7 40.16 0.4727 0.0 21.000 9.926 Vel = 14.91 0.0 40,16 14.799 KFactor 10.44 S8 39.10 1.049 T 5.0 12.000 7.800 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 8 39.1 0.4498 0.0 21.000 . 9.446 VeI= 14.51 0.0 39.10 13.889 KFactor 10.49 S9 39.10 1.049 T 5.0 12.000 7.800 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 9 39.1 0.4498 0.0 21.000 9.446 Vel = 14.51 0.0 39.10 13.889 KFactor 10.49 S10 40.12 1.049 T 5.0 12.000 8.214 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 10 40.12 0.4718 0.0 21.000 9.908 Vel = 14.89 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 7 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 40.12 14.765 KFactor= 10.44 Sli 45.16 1.049 T 5.0 12.000 10.406 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 11 45.16 0.5872 0.0 21.000 12.332 VeI= 16.76 0.0 45.16 19.381 KFactor= 10.26 S12 41.59 1.049 T 5.0 12.000 8.826 KFactor = 14.00 to 120.0 2E 4.0 9.000 -3.357 12 41.59 0.5043 0.0 21.000 10.590 Vel = 15.44 0.0 41.59 - 16.059 KFactor= 10.38 S13 40.64 1.049 T 5.0 12.000 8.427 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 13 40.64 0.4831 0.0 21.000 10.145 Vel = 15.09 0.0 40.64 15.215 KFactor= 10.42 S14 40.65 1.049 T 5.0 12.000 8.430 K Factor= 14.00 to 120.0 2E 4.0 9.000 -3.357 14 40.65 0.4833 0.0 21.000 10.149 Vel = 15.09 0.0 40.65 15.222 KFactor= 10.42 S15 . 41.86 1.049 T 5.0 12.000 8.942 K Factor = 14.00 to 120.0 2E 4.0 9.000 -3.357 15 41.86 0.5104 0.0 21.000 10.719 Vel = 15.54 0.0 41.86 16.304 KFactor= 10.37 1 -75.81 1.61 0.0 16.000 18.044 to 120.0 0.0 0.0 0.0 2 -75.81 -0.1901 0.0 16.000 -3.041 Vel = 11.95 2 40.40 1.61 0.0 16.000 15.003 to 120.0 0.0 0.0 0.0 3 -35.41 -0.0464 0.0 16.000 -0.743 Vel = 5.58 3 39.54 1.61 0.0 10.830 14.260 to 120.0 0.0 0.0 0.0 4 4.13 0.0008 0.0 10.830 0.009 Vel = 0.65 4 39.54 1.61 0.0 16.000 14.269 to 120.0 0.0 0.0 0.0 5 43.67 0.0685 0.0 16.000 1.096 Vel = 6.88 0.0 43.67 15.365 KFactor= 11.14 1 119.57 1.61 T 8.0 17.083 18.044 to 120.0 0.0 8.000 0.758 Bi 119.57 0.4416 0.0 25.083 11.076 Vel = 18.84 0.0 119.57 29.878 KFactor 21.87 6 -79.67 1.61 0.0 16.000 18.133 to 120.0 0.0 0.0 0.0 7 -79.67 -0.2084 0.0 16.000 -3.334 Vel = 12.56 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 8 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7 40.17 1.61 0.0 16.000 14.799 to 120.0 0.0 0.0 0.0 8 -39.5-0.0569 0.0 16.000 -0.910 Vel = 6.22 8 39.10 1.61 0.0 10.000 13.889 to 120.0 0.0 0.0 0.0 9 -0.4 0.0 0.0 10.000 0.0 Vel = 0.06 9 39.10 1.61 0.0 16.000 13.889 to 120.0 0.0 0.0 0.0 10 38.7 0.0548 0.0 16.000 0.876 Vel = 6.10 0.0 38.70 14.765 K Factor = 10.07 6 123.52 1.61 T 8.0 16.670 18.133 to 120.0 0.0 8.000 0.758 B3 123.52 0.4689 0.0 24.670 11.568 Vel = 19.47 0.0 123.52 30.459 K Factor 22.38 11 -79.51 1.61 0.0 16.000 19.381 to 120.0 0.0 0.0 0.0 12 -79.51 -0.2076 0.0 16.000 -3.322 Vel = 12.53 12 41.59 1.61 0.0 16.000 16.059 to 120.0 0.0 0.0 0.0 13 -37.92 -0.0528 0.0 16.000 -0.844 Vel = 5.98 13 40.64 1.61 0.0 16.000 15.215 to 120.0 0.0 0.0 0.0 14 2.72 0.0004 0.0 16.000 0.007 Vel = 0.43 14 40.65 1.61 0.0 16.000 15.222 to 120.0 0.0 0.0 0.0 15 43.37 0.0676 0.0 16.000 1.082 Vel = 6.83 0.0 43.37 16.304 KFactor= 10.74 11 124.68 1.61 T 8.0 17.083 19.381 to 120.0 0.0 8.000 0.758 B5 124.68 0.4771 0.0 25.083 11.967 Vel = 19.65 0.0 124.68 32.106 KFactor= 22.00 5 84.48 1.61 T 8.0 60.000 15.365 to 120.0 0.0 8.000 0.758 Fl 84.48 0.2322 0.0 68.000 15.792 Vel = 13.31 0.0 84.48 31.915 KFactor= 14.95 10 78.82 1.61 T 8.0 65.790 14.765 to 120.0 2E 8.0 16.000 0.758 F3 78.82 0.2043 0.0 81.790 16.707 Vel = 12.42 0.0 78.82 32.230 K Factor = 13.88 15 85.23 1.61 T 8.0 62.916 16.304 to 120.0 0.0 8.000 0.758 F5 85.23 0.2361 0.0 70.916 16.740 Vel = 13.43 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 9 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 85.23 33.802 K Factor = 14.66 B2 17.15 1.61 2T 16.0 136.000 30.278 to 120.0 0.0 16.000 0.0 F2 17.15 0.0122 0.0 152.000 1.848 Vel = 2.70 0.0 17.15 32.126 KFactor= 3.03 B4 16.95 1.61 2T 16.0 136.000 30.980 to 120.0 0.0 16.000 0.0 F4 16.95 0.0119 0.0 152.000 1.808 Vel = 2.67 0.0 16.95 32.788 KFactor= 2.96 B5 16.37 1.61 2T 16.0 136.000 32.106 to 120.0 0.0 16.000 0.0 F5 16.37 0.0112 0.0 152.000 1.696 Vel = 2.58 0.0 16.37 33.802 KFactor= 2.82 66 42.53 1.61 E 4.0 80.000 34.544 to 120.0 2T 16.0 20.000 0.0 Cl 42.53 0.0652 0.0 100.000 6.523 Vel = 6.70 0.0 42.53 41.067 KFactor= 6.64 B7 35.52 1.61 E 4.0 80.000 36.413 to 120.0 21 16.0 20.000 0.0 C2 35.52 0.0468 0.0 100.000 4.676 Vel = 5.60 0.0 35.52 41.089 KFactor= 5.54 B8 29.40 1.61 E 4.0 80.000 37.860 to 120.0 21 16.0 20.000 0.0 C3 29.4 0.0329 0.0 100.000 3.294 Vel = 4.63 0.0 29.40 41.154 KFactor= 4.58 139 24.07 1.61 E 4.0 80.000 38.994 to 120.0 21 16.0 20.000 0.0 C4 24.07 0.0228 0.0 100.000 2.276 Vel = 3.79 0.0 24.07 41.270 K Factor = 3.75 BIO 19.47 1.61 E 4.0 80.000 39.900 to 120.0 21 16.0 20.000 0.0 C5 19.47 0.0154 0.0 100.000 1.538 Vel= 3.07 0.0 19.47 41.438 KFactor 3.02 Bli 15.54 1.61 E 4.0 80.000 40.638 to 120.0 21 16.0 20.000 0.0 C6 15.54 0.0101 0.0 100.000 1.013 Vel = 2.45 0.0 15.54 - 41.651 KFactor= 2.41 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 10 Nortek ECOH System 2 Date 1-26-15 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin B12 12.22 1.61 E 4.0 80.000 41.254 to 120.0 2T 16.0 20.000 0.0 C7 12.22 0.0065 0.0 100.000 0.650 Vet = 1.93 0.0 12.22 41.904 KFactor= 1.89 B13 9.50 1.61 E 4.0 80.000 41.780 to 120.0 2T 16.0 20.000 0.0 C8 9.5 0.0041 0.0 100.000 0.408 Vet= 1.50 0.0 9.50 42.188 KFactor = 1.46 B14 7.35 1.61 E 4.0 80.000 42.242 to 120.0 2T 16.0 20.000 0.0 C9 7.35 0.0025 0.0 100.000 0.253 Vel = 1.16 0.0 7.35 42.495 K Factor = 1.13 B15 5.78 1.61 E 4.0 80.000 42.656 to 120.0 2T 16.0 20.000 0.0 C1O 5.78 0.0016 0.0 100.000 0.163 Vet = 0.91 0.0 5.78 42.819 KFactor= 0.88 B16 4.72 1.61 E 4.0 80.000 43.035 to 120.0 2T 16.0 20.000 0.0 CII 4.72 0.0011 0.0 100.000 0.111 VeI= 0.74 0.0 4.72 43.146 KFactor= 0.72 B17 4.12 1.61 E 4.0 80.000 43.385 to 120.0 2T 16.0 20.000 0.0 C12 4.12 0.0009 0.0 100.000 0.087 Vet = 0.65 0.0 4.12 43.472 K Factor= 0.62 B18 3.92 1.61 E 4.0 80.000 43.712 to 120.0 2T 16.0 20.000 0.0 C13 3.92 0.0008 0.0 100.000 0.079 Vel = 0.62 0.0 3.92 43.791 K Factor= 0.59 B19 3.98 1.61 E 4.0 80.000 44.017 to 120.0 2T 16.0 20.000 0.0 C14 3.98 0.0008 0.0 100.000 0.082 Vel = 0.63 0.0 3.98 44.099 K Factor= 0.60 B20 4.15 1.61 E 4.0 80.000 44.301 to 120.0 2T 16.0 20.000 0.0 C15 4.15 0.0009 0.0 100.000 0.088 Vel = 0.65 0.0 4.15 44.389 K Factor 0.62 B21 4.28 1.61 E 4.0 80.000 44.563 to 120.0 2T 16.0 20.000 0.0 C16 4.28 0.0009 0.0 100.000 0.093 Vet = 0.67 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 11 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe PV ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 4.28 44.656 K Factor = 0.64 B22 90.75 4.26 E 13.167 90.000 44.996 to 120.0 2T 52.668 65.835 0.0 017 90.75 0.0023 0.0 155.835 0.361 Vel = 2.04 0.0 90.75 45.357 KFactor= 13.47 Cl -44.37 1.61 2T 16.0 56.000 41.067 to 120.0 0.0 16.000 0.0 F6 -44.37 -0.0706 0.0 72.000 -5.080 Vel = 6.99 0.0 -44.37 35.987 K Factor= -7.40 C2 -36.16 1.61 21 16.0 56.000 41.089 to 120.0 0.0 16.000 0.0 F7 -36.16 -0.0483 0.0 72.000 -3.479 Vel = 5.70 0.0 -36.16 37.610 KFactor= -5.90 C3 -29.05 1.61 2T 16.0 56.000 41.154 to 120.0 0.0 16.000 0.0 F8 -29.05 -0.0322 0.0 72.000 -2.321 Vel = 4.58 0.0 -29.05 38.833 K Factor -4.66 C4 -22.93 1.61 2T 16.0 56.000 41.270 to 120.0 0.0 16.000 0.0 F9 -22.93 -0.0208 0.0 72.000 -1.498 Vel = 3.61 0.0 -22.93 39.772 K Factor -3.64 CS -17.68 1.61 21 16.0 56.000 41.438 to 120.0 0.0 16.000 0.0 F10 -17.68 -0.0129 0.0 72.000 -0.927 Vel = 2.79 0.0 N -17.68 40.511 KFactor= -2.78 06 -13.19 1.61 21 16.0 56.000 41.651 to 120.0 0.0 16.000 0.0 F11 -13.19 -0.0075 0.0 72.000 -0.539 Vel= 2.08 0.0 -13.19 41.112 KFactor= -2.06 07 -9.35 1.61 2T 16.0 56.000 41.904 to 120.0 0.0 16.000 0.0 F12 -9.35 -0.0040 0.0 72.000 -0.286 Vel = 1.47 0.0 -9.35 41.618 KFactor= -1.45 C8 -6.01 1.61 2T 16.0 56.000 42.188 to 120.0 0.0 16.000 0.0 F13 -6.01 -0.0018 0.0 72.000 -0.126 Vel = 0.95 0.0 -6.01 42.062 KFactor= -0.93 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final' Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 12 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C9 -2.68 1.61 2T 16.0 56.000 42.495 to 120.0 0.0 16.000 0.0 F14 -2.68 -0.0004 0.0 72.000 -0.028 Vet = 0.42 0.0 -2.68 42.467 K Factor = -0.41 dO 3.10 1.61 2T 16.0 56.000 42.819 to 120.0 0.0 16.000 0.0 F15 3.1 0.0005 0.0 72.000 0.037 Vet = 0.49 0.0 3.10 42.856 KFactor= 0.47 Cli 5.78 1.61 2T 16.0 56.000 43.146 to 120.0 0.0 16.000 0.0 F16 5.78 0.0016 0.0 72.000 0.117 Vel = 0.91 0.0 5.78 43.263 K Factor = 0.88 C12 8.44 1.61 21 16.0 56.000 43.472 to 120.0 0.0 16.000 0.0 F17 8.44 0.0033 0.0 72.000 0.236 Vel = 1.33 0.0 8.44 43.708 K Factor = 1.28 C13 11.49 1.61 2T 16.0 56.000 43.791 to 120.0 0.0 16.000 0.0 F18 11.49 0.0058 0.0 72.000 0.418 Vel = 1.81 0.0 11.49 ' 44.209 K Factor = 1.73 C14 15.12 1.61 21 16.0 56.000 44.099 to 120.0 0.0 16.000 0.0 F19 15.12 0.0096 0.0 72.000 0.693 Vet = 2.38 0.0 15.12 44.792 KFactor 2.26 C15 19.42 1.61 21 16.0 56.000 44.389 to 120.0 0.0 16.000 0.0 F20 19.42 0.0153 0.0 72.000 1.102 Vet = 3.06 0.0 19.42 45.491 K Factor = 2.88 C16 24.53 1.61 21 16.0 56.000 44.656 to 120.0 0.0 16.000 0.0 F21 24.53 0.0236 0.0 72.000 1.697 Vet = 3.87 0.0 24.53 46.353 K Factor = 3.60 C17 410.85 4.26 T 26.334 56.000 45.357 to 120.0 0.0 26.334 0.0 F22 410.85 0.0379 0.0 82.334 3.121 Vet = 9.25 0.0 410.85 48.478 KFactor= 59.01 Bi 119.57 2.635 0.0 10.000 29.878 to 120.0 0.0 0.0 0.0 B2 119.57 0.0400 0.0 10.000 0.400 Vel = 7.03 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 13 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn B2 -17.15 2.635 0.0 6.000 30.278 to 120.0 0.0 0.0 0.0 B3 102.42 0.0302 0.0 6.000 0.181 Vel = 6.03 B3 123.51 2.635 0.0 4.000 30.459 to 120.0 0.0 0.0 0.0 B4 225.93 0.1302 0.0 4.000 0.521 Vel = 13.29 B4 -16.95 2.635 0.0 10.000 30.980 to 120.0 0.0 0.0 0.0 B5 208.98 0.1126 0.0 10.000 1.126 Vel= 12.30 B5 108.31 2.635 0.0 10.000 32.106 to 120.0 0.0 0.0 0.0 B6 317.29 0.2438 0.0 10.000 2.438 Vel = 18.67 B6 -42.53 2.635 0.0 10.000 34.544 to 120.0 0.0 0.0 0.0 B7 274.76 0.1869 0.0 10.000 1.869 Vel = 16.17 B7 -35.52 2.635 0.0 10.000 36.413 to 120.0 0.0 0.0 0.0 B8 239.24 0.1447 0.0 10.000 1.447 Vel = 14.08 B8 -29.40 2.635 0.0 10.000 37.860 to 120.0 0.0 0.0 0.0 B9 209.84 0.1134 0.0 10.000 1.134 Vel = 12.35 B9 -24.07 2.635 0.0 10.000 38.994 to 120.0 0.0 0.0 0.0 B10 185.77 0.0906 0.0 10.000 0.906 Vel = 10.93 B10 -19.47 2.635 0.0 10.000 39:900 to 120.0 0.0 0.0 0.0 Bil 166.3 0.0738 0.0 10.000 0.738 Vel = 9.78 Bil -15.54 2.635 0.0 10.000 40.638 to 120.0 0.0 0.0 0.0 B12 150.76 0.0616 0.0 10.000 0.616 Vel = 8.87 612 -12.22 2.635 0.0 10.000 41.254 to 120.0 0.0 0.0 0.0 B13 138.54 0.0526 0.0 10.000 0.526 Vel = 8.15 B13 -9.50 2.635 0.0 10.000 41.780 to 120.0 0.0 0.0 0.0 B14 129.04 0.0462 0.0 10.000 0.462 Vel = 7.59 B14 -7.34 2.635 0.0 10.000 42.242 to 120.0 0.0 0.0 0.0 B15 121.7 0.0414 0.0 10.000 0.414 Vel = 7.16 B15 -5.78 2.635 0.0 10.000 42.656 to 120.0 0.0 0.0 0.0 B16 115.92 0.0379 0.0 10.000 0.379 Vel = 6.82 616 -4.72 2.635 0.0 10.000 43.035 to 120.0 0.0 0.0 0.0 B17 111.2 0.0350 0.0 10.000 0.350 Vel = 6.54 B17 -4.12 2.635 0.0 10.000 43.385 to 120.0 0.0 0.0 0.0 B18 107.08 0.0327 0.0 10.000 0.327 Vel = 6.30 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 14 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn B18 -3.92 2.635 0.0 10.000 43.712 to 120.0 0.0 0.0 0.0 B19 103.16 0.0305 0.0 10.000 0.305 Vel = 6.07 B19 -3.98 2.635 0.0 10.000 44.017 to 120.0 0.0 0.0 0.0 B20 99.18 0.0284 0.0 10.000 0.284 Vel = 5.84 B20 -4.14 2.635 0.0 10.000 44.301 to 120.0 0.0 0.0 0.0 621 95.04 0.0262 0.0 10.000 0.262 VeI= 5.59 B21 -4.29 2.635 T 16.474 1.500 44.563 to 120.0 0.0 16.474 0.0 B22 90.75 0.0241 0.0 17.974 0.433 Vel = 5.34 0.0 90.75 44.996 KFactor= 13.53 Cl 86.90 4.26 0.0 10.000 41.067 to 120.0 0.0 0.0 0.0 C2 86.9 0.0022 0.0 10.000 0.022 Vel = 1.96 C2 71.68 4.26 0.0 10.000 41.089 to 120.0 0.0 0.0 0.0 C3 158.58 0.0065 0.0 10.000 0.065 Vel = 3.57 C3 58.45 4.26 0.0 10.000 41.154 to 120.0 0.0 0.0 0.0 C4 217.03 0.0116 0.0 10.000 0.116 Vel = 4.89 C4 47.00 4.26 0.0 10.000 41.270 to 120.0 0.0 0.0 0.0 C5 264.03 0.0168 0.0 10.000 0.168 Vel = 5.94 C5 37.16 4.26 0.0 10.000 41.438 to 120.0 0.0 0.0 0.0 C6 301.19 0.0213 0.0 10.000 0.213 Vel = 6.78 C6 28.73 4.26 0.0 10.000 41.651 to 120.0 0.0 0.0 0.0 C7 329.92 0.0253 0.0 10.000 0.253 Vel = 7.43 C7 21.57 4.26 0.0 10.000 41.904 to 120.0 0.0 0.0 0.0 C8 351.49 0.0284 0.0 10.000 0.284 Vel = 7.91 C8 15.51 4.26 0.0 10.000 42.188 to 120.0 0.0 0.0 0.0 C9 367.0 0.0307 0.0 10.000 0.307 Vel = 8.26 C9 10.03 4.26 0.0 10.000 42.495 to 120.0 0.0 0.0 0.0 C10 377.03 0.0324 0.0 10.000 0.324 Vel = 8.49 dO 2.68 4.26 0.0 10.000 42.819 to 120.0 0.0 0.0 0.0 Cli 379.71 0.0327 0.0 10.000 0.327 Vel = 8.55 Cli -1.06 4.26 0.0 10.000 43.146 to 120.0 0.0 0.0 0.0 C12 378.65 0.0326 0.0 10.000 0.326 Vel = 8.52 C12 -4.31 4.26 0.0 10.000 43.472 to 120.0 0.0 0.0 0.0 C13 374.34 0.0319 0.0 10.000 0.319 Vel = 8.43 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 15 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C13 -7.58 4.26 0.0 10.000 43.791 to 120.0 0.0 0.0 0.0 C14 366.76 0.0308 0.0 10.000 0.308 Vel = 8.26 C14 -11.14 4.26 0.0 10.000 44.099 to 120.0 0.0 0.0 0.0 C15 355.62 0.0290 0.0 10.000 0.290 Vel = 8.00 C15 -15.28 4.26 0.0 10.000 44.389 to 120.0 0.0 0.0 0.0 C16 340.34 0.0267 0.0 10.000 0.267 Vel = 7.66 C16 -20.24 4.26 T 26.334 3.000 44.656 to 120.0 0.0 26.334 0.0 C17 320.1 0.0239 0.0 29.334 0.701 Vel = 7.21 0.0 320.10 45.357 KFactor= 47.53 Fl 84.48 2.635 0.0 10.000 31.915 to 120.0 0.0 0.0 0.0 F2 84.48 0.0211 0.0 10.000 0.211 Vel = 4.97 F2 17.15 2.635 0.0 3.500 32.126 to 120.0 0.0 0.0 0.0 F3 101.63 0.0297 0.0 3.500 0.104 Vel = 5.98 F3 78.82 2.635 0.0 6.500 32.230 to 120.0 0.0 0.0 0.0 F4 180.45 0.0858 0.0 6.500 0.558 Vel = 10.62 F4 16.95 2.635 0.0 10.000 32.788 to 120.0 0.0 0.0 0.0 F5 197.4 0.1014 0.0 10.000 1.014 Vel = 11.61 ES 101.61 2.635 0.0 10.000 33.802 to 120.0 0.0 0.0 0.0 E6 299.01 0.2185 0.0 10.000 2.185 Vel = 17.59 F6 -44.38 2.635 0.0 10.000 35.987 to 120.0 0.0 0.0 0.0 F7 254.63 0.1623 0.0 10.000 1.623 Vel = 14.98 F7 -36.15 2.635 0.0 10.000 37.610 to 120.0 0.0 0.0 0.0 F8 218.48 0.1223 0.0 10.000 1.223 Vel = 12.85 F8 -29.06 2.635 0.0 10.000 38.833 to 120.0 0.0 0.0 0.0 F9 189.42 0.0939 0.0 10.000 0.939 Vel = 11.14 F9 -22.93 2.635 0.0 10.000 39.772 to 120.0 0.0 0.0 0.0 F10 166.49 0.0739 0.0 10.000 0.739 Vel = 9.80 E10 -17.68 2.635 0.0 10.000 40.511 to 120.0 0.0 0.0 0.0 Eli 148.81 0.0601 0.0 10.000 0.601 Vel = 8.76 Eli -13.19 2.635 0.0 10.000 41.112 to 120.0 0.0 0.0 0.0 E12 135.62 0.0506 0.0 10.000 0.506 Vel = 7.98 E12 -9.36 2.635 0.0 10.000 41.618 to 120.0 0.0 0.0 0.0 E13 126.26 0.0444 0.0 10.000 0.444 Vel = 7.43 Computer Programs by Hydratec Inc. Revision: 50.52.1 Finall Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 16 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn F13 -6.01 2.635 0.0 10.000 42.062 to 120.0 0.0 0.0 0.0 F14 120.25 0.0405 0.0 10.000 0.405 Vel = 7.07 F14 -2.68 2.635 0.0 10.000 42.467 to 120.0 0.0 0.0 0.0 F15 117.57 0.0389 0.0 10.000 0.389 Vel = 6.92 F15 3.09 2.635 0.0 10.000 42.856 to 120.0 0.0 0.0 0.0 F16 120.66 0.0407 0.0 10.000 0.407 Vel = 7.10 F16 5.78 2.635 0.0 10.000 43.263 to 120.0 0.0 0.0 0.0 F17 126.44 0.0445 0.0 10.000 0.445 Vel = 7.44 F17 8.44 2.635 0.0 10.000 43.708 to 120.0 0.0 0.0 0.0 F18 134.88 0.0501 0.0 10.000 0.501 Vel = 7.94 F18 11.49 2.635 0.0 10.000 44.209 to 120.0 0.0 0.0 0.0 F19 146.37 0.0583 0.0 10.000 0.583 Vel = 8.61 F19 15.12 2.635 0.0 10.000 44.792 to 120.0 0.0 0.0 0.0 F20 161.49 0.0699 0.0 10.000 0.699 Vel = 9.50 F20 19.42 2.635 0.0 10.000 45.491 to 120.0 0.0 0.0 0.0 F21 180.91 0.0862 0.0 10.000 0.862 Vel = 10.64 F21 24.53 2.635 1 16.474 3.000 46.353 to 120.0 0.0 16.474 0.0 F22 205.44 0.1091 0.0 19.474 2.125 Vel = 12.09 0.0 205.44 48.478 K Factor= 29.51 F22 616.29 4.26 2E 26.334 17.000 48.478 to 120.0 0.0 26.334 0.0 TOR 616.29 0.0803 0.0 43.334 3.479 Vel = 13.87 TOR 0.0 4.26 0.0 18.000 51.957 to 120.0 0.0 0.0 7.796 BOR 616.29 0.0802 0.0 18.000 1.444 Vel = 13.87 BOR 0.0 4.1 E 14.534 12.000 61.197 to 140.0 0.0 14.534 2.166 UG1 616.29 0.0727 0.0 26.534 1.929 Vel = 14.98 UG1 0.0 4.07 2E 31.864 125.000 65.292 to 150.0 0.0 31.864 -2.599 UG6 616.29 0.0663 0.0 156.864 10.407 Vel = 15.20 UG6 0.0 4.1 E 14.534 6.000 73.100 to 140.0 0.0 14.534 0.0 BFI 616.29 0.0727 0.0 20.534 1.493 Vel = 14.98 BF1 0.0 4.1 2E 29.067 6.000 74.593 to 140.0 0.0 29.067 8.599 * Fixed Loss = 6 BF2 616.29 0.0727 0.0 35.067 2.549 Vel = 14.98 BF2 0.0 4.1 E 14.534 6.000 85.741 to 140.0 0.0 14.534 0.0 UG7 616.29 0.0728 0.0 20.534 1.494 Vel = 14.98 Computer Programs by Hydratec Inc. Revision: 50.52.1 Finl Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 17 Nortek ECOH System 2 Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin UG7 0.0 4.07 E 15.932 40.000 87.235 to 150.0 T 31.864 50.982 0.0 UG8 616.29 0.0663 G 3.186 90.982 6.035 Vel = 15.20 UG8 0.0 9.42 2E 49.22 62.000 93.270 to 150.0 T 55.931 110.744 0.0 SCR 616.29 0.0011 G 5.593 172.744 0.192 Vel = 2.84 500.00 Qa = 500.00 1116.29 93.462 K Factor = 115.47 Computer Programs by Hydratec Inc. Revision: 50.52.1 - - - Fire Protection by Computer Design Cosco Fire Protection, Inc 4990 Greencraig Lane San Diego, CA 92123 858-444-2000 Job Name : Nortek - T.I. ECOH - PIR/FLEX Open Building : Suite #100 Location : 5919 Sea Otter Place System : 6 Contract 10.CA_5385 Data File Nortek ECOH - 16x16 System 6 Calc.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Cosco Fire Protection, Inc Page 1 Nortek - Ti. ECOH - PIR/FLEX Open Date 1-26-18 Hydraulic Design Information Sheet Name - Nortek - T.I. Date - 01-26-18 Location - 5919 Sea Otter Place Building - Suite #100 System No. - 6 Contractor - Cosco Fire Protection Inc. Contract No. - 10.CA 5385 Calculated By - M. Lovely Drawing No. - FP202 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - Ordinary Hazard - Room #177 PIR/FLEX Open S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 2500 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make Viking D Area Per Sprinkler - 256 ( ) Dry Model VK572 E Elevation at Highest Outlet - 14 ( ) Deluge Size 3/4 S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 14.0 I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 500 N Note Calculation Flow Required - 979.734 Press Required - 104.140 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-01-17 Cap. - T Time of Test - N/A Rated Cap.-. Elev.- E Static Press - 126 © Press - R Residual Press - 113 Elev. - Well Flow - 3425 Proof Flow S Elevation - -3 U P Location - North end of Sea Otter Palce P L Source of Information - City of Carlsbad Y C Commodity General Storage Class N/A Location O Storage Ht. 8 Area Aisle W. M Storage Method: Solid Piled Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cosco Fire Protection, Inc Page 2 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 City Water Supply: Demand: Cl - Static Pressure : 113.4 Dl - Elevation : 7.363 C2 - Residual Pressure: 100.4 D2 - System Flow : 479.784 C2 - Residual Flow : 3425 D2 - System Pressure :104.140 Hose ( Demand) : 500 D3 - System Demand : 979.784 Safety Margin : 7.976 150 - 140 - _____ ________ __________ 130 p120 C1 R 110 E 100 - L - C2 - - D3 890 -- S80 -- u 70 R6° E5° 40 30 20 10 Dl 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cosco Fire Protection, Inc Nortek - T.I. ECOH - PIR/FLEX Open Page Date 3 1-26-18 Fitting Legend Abbrev. Name % % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no N adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure I Flow Summary - STANDARD Cosco Fire Protection, Inc Page 4 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. EC1 14.0 14 8.43 na 40.66 0.15 256 7.8 EC2 14.0 14 7.99 na 39.56 0.15 256 7.8 EC3 14.0 14 7.98 na 39.56 0.15 256 7.8 EC4 14.0 14 8.32 na 40.39 0.15 256 7.8 EC5 0.0 28.68 na EC6 14.0 14 8.11 na 39.87 0.15 256 7.8 EC7 14.0 14 7.8 na 39.1 0.15 256 7.8 EC8 14.0 14 7.81 na 39.12 0.15 256 7.8 EC9 14.0 14 8.27 na 40.26 0.15 256 7.8 EC10 0.0 28.02 na ECu 1 14.0 14 8.45 na 40.7 0.15 256 7.8 EC12 14.0 14 8.09 na 39.83 0.15 256 7.8 EC13 14.0 14 8.1 na 39.84 0.15 256 7.8 EC14 14.0 14 8.54 na 40.91 0.15 256 7.8 EC15 0.0 29.53 na 1 21.75 17.16 na 2 21.75 16.12 na 3 21.75 16.11 na 4 21.75 16.91 na 5 21.75 19.26 na 6 21.75 16.41 na 7 21.75 15.69 na 8 21.75 15.7 na 9 21.75 16.78 na 10 21.75 18.6 na 11 21.75 17.2 na 12 21.75 16.38 na 13 21.75 16.38 na 14 21.75 17.41 na 15 21.75 20.11 na M5 20.0 33.27 na M6 20.0 34.73 na M7 20.0 36.22 na MB 20.0 37.77 na M9 20.0 39.41 na M10 20.0 41.16 na Mil 20.0 43.08 na M12 20.0 45.25 na M13 20.0 47.73 na M14 20.0 50.65 na M15 20.0 54.14 na M16 20.0 58.39 na Ml 20.0 30.32 na M2 20.0 30.52 na M3 20.0 31.19 na M4 20.0 31.86 na M17 20.0 63.75 na M20 20.0 30.1 na M21 20.0 30.28 na M22 20.0 30.97 na M23 20.0 31.66 na M24 20.0 33.16 na M25 20.0 34.61 na M26 20.0 36.03 na M27 20.0 37.39 na M28 20.0 38.67 na M29 20.0 39.85 na M30 20.0 40.89 na M31 20.0 41.77 na M32 20.0 42.45 na M33 20.0 42.92 na M34 20.0 43.18 na Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - Standard Cosco Fire Protection, Inc Page 5 Nortek -1.1. ECOH - PIR/FLEX Open Date 1-26-18 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. M40 20.0 71.41 na TOR 2.0 81.31 na BOR 0.0 83.75 na UG1 -3.0 85.15 na UG2 -3.0 86.18 na UG3 -3.0 88.55 na BF1 2.0 87.33 na BF2 2.0 95.05 na UG4 -3.0 98.16 na UG5 -3.0 103.19 na SCR -3.0 104.14 na 500.0 The maximum velocity is 28.23 and it occurs in the pipe between nodes M16 and M17 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams -2007 Cosco Fire Protection, Inc Page 6 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "c",,/ or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn EC1 40.66 1.049 T 5.0 14.000 8.433 KFactor 14.00 to 120.0 3E 6.0 11.000 -3.357 1 40.66 0.4835 0.0 25.000 12.087 Vel = 15.09 0.0 40.66 17.163 K Factor= 9.81 EC2 39.56 1.049 1 5.0 14.000 7.986 KFactor = 14.00 to 120.0 3E 6.0 11.000 -3.357 2 39.56 0.4597 0.0 25.000 11.493 Vel = 14.69 0.0 39.56 16.122 KFactor= 9.85 EC3 39.56 1.049 1 5.0 14.000 7.983 KFactor = 14.00 to 120.0 3E 6.0 11.000 -3.357 3 39.56 0.4596 0.0 25.000 11.489 Vel = 14.69 0.0 39.56 16.115 KFactor= 9.85 EC4 40.39 1.049 T 5.0 14.000 8.323 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 4 40.39 0.4776 0.0 25.000 11.941 Vet = 14.99 0.0 - 40.39 16.907 KFactor 9.82 ECS 0.0 1.049 T 5.0 14.000 28.677 to 120.0 3E 6.0 11.000 -9A20 5 0.0 0.0 0.0 25.000 0.0 Vet = 0 0.0 0.0 19.257 K Factor = 0 EC6 39.87 1.049 T 5.0 14.000 8.111 K Factor= 14.00 to 120.0 3E 6.0 .11.000 -3.357 6 39.87 0.4664 0.0 25.000 11.659 Vel = 14.80 0.0 39.87 16.413 K Factor = 9.84 EC7 39.10 1.049 T 5.0 14.000 7.800 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 7 39.1 0.4498 0.0 25.000 11.245 Vel = 14.51 0.0 39.10 15.688 KFactor= 9.87 EC8 39.12 1.049 1 5.0 14.000 7.806 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 8 39.12 0.4501 0.0 25.000 11.253 Vel = 14.52 0.0 39.12 15.702 K Factor = 9.87 EC9 40.26 1.049 T 5.0 14.000 8.269 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 9 40.26 0.4748 0.0 25.000 11.869 Vet = 14.95 0.0 40.26 16.781 K Factor 9.83 EC10 0.0 1.049 1 5.0 14.000 28.021 to 120.0 3E 6.0 11.000 -9.420 10 0.0 0.0 0.0 25.000 0.0 Vet = 0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 7 Nortek - TI. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 0.0 18.601 K Factor 0 ECu 1 40.70 1.049 T 5.0 14.000 8.451 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 11 40.7 0.4844 0.0 25.000 12.110 Vet = 15.11 0.0 40.70 17.204 K Factor = 9.81 EC12 39.83 1.049 T 5.0 14.000 8.095 KFactor = 14.00 to 120.0 3E 6.0 11.000 -3.357 12 39.83 0.4655 0.0 25.000 11.637 Vet = 14.79 0.0 39.83 16.375 KFactor= 9.84 EC13 39.84 1.049 T 5.0 14.000 8.097 K Factor = 14.00 to 120.0 3E 6.0 11.000 -3.357 13 39.84 0.4656 0.0 25.000 11.640 Vel = 14.79 0.0 39.84 16.380 KFactor 9.84 EC14 40.91 1.049 T 5.0 14.000 8.538 KFactor = 14.00 to 120.0 3E 6.0 11.000 -3.357 14 40.91 0.4890 0.0 25.000 12.225 Vet = 15.19 0.0 40.91 17.406 KFactor = 9.81 EC15 0.0 1.049 T 5.0 14.000 29.526 to 120.0 3E 6.0 11.000 -9.420 15 0.0 0.0 0.0 25.000 0.0 Vet = 0 0.0 0.0 20.106 K Factor =0 1 -42.47 1.61 0.0 16.000 17.163 to 120.0 0.0 0.0 0.0 2 -42.47 -0.0651 0.0 16.000 -1.041 Vet= 6.69 2 39.57 1.61 0.0 16.000 16.122 to 120.0 0.0 0.0 0.0 3 -2.9 -0.0004 0.0 16.000 -0.007 Vet = 0.46 3 39.55 1.61 0.0 16.000 16.115 to 120.0 0.0 0.0 0.0 4 36.65 0.0495 0.0 16.000 0.792 Vet = 5.78 4 40.39 1.61 0.0 12.000 16.907 to 120.0 0.0 0.0 0.0 5 77.04 0.1958 0.0 12.000 2.350 Vel = 12.14 5 0.0 1.61 E 4.0 39.500 19.257 to 120.0 T 8.0 12.000 0.758 M20 77.04 0.1958 0.0 51.500 10.085 Vet = 12.14 0.0 77.04 30.100 KFactor= 14.04 6 -34.93 1.61 0.0 16.000 16.413 to 120.0 0.0 0.0 0.0 7 -34.93 -0.0453 0.0 16.000 -0.725 Vet = 5.50 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 8 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 7 39.10 1.61 0.0 16.000 15.688 to 120.0 0.0 0.0 0.0 8 4.17 0.0009 0.0 16.000 0.014 Vel = 0.66 8 39.12 1.61 0.0 16.000 15.702 to 120.0 0.0 0.0 0.0 9 43.29 0.0674 0.0 16.000 1.079 Vel = 6.82 9 40.26 1.61 0.0 8.000 16.781 to 120.0 0.0 0.0 0.0 10 83.55 0.2275 0.0 8.000 1.820 Vet = 13.17 10 0.0 1.61 E 4.0 36.000 18.601 to 120.0 1 8.0 12.000 0.758 M21 83.55 0.2275 0.0 48.000 10.919 Vet = 13.17 0.0 83.55 30.278 KFactor 15.18 11 -37.53 1.61 0.0 16.000 17.204 to 120.0 0.0 0.0 0.0 12 -37.53 -0.0518 0.0 16.000 -0.829 Vel = 5.91 12 39.83 1.61 0.0 16.000 16.375 to 120.0 0.0 0.0 0.0 13 2.3 0.0003 0.0 16.000 0.005 Vet = 0.36 13 39.84 1.61 0.0 16.000 16.380 to 120.0 0.0 0.0 0.0 14 42.14 0.0641 0.0 16.000 1.026 Vet= 6.64 14 40.90 1.61 0.0 12.000 17.406 to 120.0 0.0 0.0 0.0 15 83.04 0.2250 0.0 12.000 2.700 Vet = 13.09 15 0.0 1.61 E 4.0 36.000 20.106 to 120.0 T 8.0 12.000 0.758 M23 83.04 0.2250 0.0 48.000 10.798 Vet = 13.09 0.0 83.04 31.662 KFactor= 14.76 1 83.12 1.61 E 4.0 43.000 17.163 to - 120.0 T 8.0 12.000 0.758 Ml 83.12 0.2254 0.0 55.000 12.395 Vet = 13.10 0.0 83.12 30.316 KFactor 15.10 6 74.80 1.61 E 4.0 60.000 16.413 to 120.0 T 8.0 12.000 0.758 M2 74.8 0.1854 0.0 72.000 13.349 Vet = 11.79 0.0 74.80 30.520 KFactor= 13.54 11 78.23 1.61 E 4.0 57.000 .17.204 to 120.0 T 8.0 12.000 0.758 M4 78.23 0.2014 0.0 69.000 13.900 Vet = 12.33 0.0 78.23 31.862 KFactor= 13.86 M5 -3.69 1.61 2E 8.0 139.500 33.274 to. 120.0 2T 16.0 24.000 0.0 M24 -3.69 -0.0007 0.0 163.500 -0.116 Vet = 0.58 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 9 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -3.69 33.158 K Factor = -0.64 M6 -3.67 1.61 2E 8.0 139.500 34.727 to 120.0 21 16.0 24.000 0.0 M25 -3.67 -0.0007 0.0 163.500 -0.115 Vel = 0.58 0.0 -3.67 34.612 K Factor -0.62 M7 -4.90 1.61 2E 8.0 139.500 36.221 to 120.0 21 16.0 24.000 0.0 M26 -4.9 -0.0012 0.0 163.500 -0.195 Vel = 0.77 0.0 -4.90 36.026 KFactor= -0.82 M8 -7.08 1.61 2E 8.0 139.500 37.772 to 120.0 21 16.0 24.000 0.0 M27 -7.08 -0.0024 0.0 163.500 -0.387 Vel 1.12 0.0 -7.08 37.385 KFactor= -1.16 M9 -10.02 1.61 2E 8.0 139.500 39.405 to 120.0 21 16.0 24.000 0.0 M28 -10.02 -0.0045 0.0 163.500 -0.736 Vel = 1.58 0.0 -10.02 38.669 KFactor= -1.61 M10 -13.69 1.61 2E 8.0 139.500 41.159 to 120.0 21 16.0 24.000 0.0 M29 -13.69 -0.0080 0.0 163.500 -1.310 Vel = 2.16 0.0 -13.69 39.849 K Factor -2.17 Mu -18.08 1.61 2E 8.0 139.500 43.084 to 120.0 21 16.0 24.000 0.0 M30 -18.08 -0.0134 0.0 163.500 -2.191 Vel = 2.85 0.0 -18.08 40.893 KFactor -2.83 M12 -23.20 1.61 2E 8.0 139.500 45.245 to 120.0 21 16.0 24.000 0.0 M31 -23.2-0.0213 0.0 163.500 -3.475 Vel = 3.66 0.0 -23.20 41.770 KFactor= -3.59 M13 -29.08 1.61 2E 8.0 139.500 47.729 to 120.0 2T 16.0 24.000 0.0 M32 -29.08 -0.0323 0.0 163.500 -5.277 Vel = 4.58 0.0 -29.08 42.452 K Factor = -4.46 M14 -35.72 1.61 2E 8.0 139.500 50.646 to 120.0 21 16.0 24.000 0.0 M33 -35.72 -0.0472 0.0 163.500 -7.725 Vel = 5.63 0.0 -35.72 42.921 K Factor = -5.45 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc . Page 10 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn M15 -43.15 1.61 2E 8.0 139.500 54.138 to 120.0 2T 16.0 24.000 0.0 M34 -43.15 -0.0670 0.0 163.500 -10.957 Vel = 6.80 0.0 -43.15 43.181 KFactor= -6.57 M16 -51.36 1.61 2E 8.0 139.500 58.389 to 120.0 2T 16.0 24.000 8.662 M35 -51.36 -0.0925 0.0 163.500 -15.124 Vel = 8.09 0.0 -51.36 51.927 KFactor= -7.13 Ml 83.12 2.635 0.0 10.000 30.316 to 120.0 0.0 0.0 0.0 M2 83.12 0.0204 0.0 10.000 0.204 Vel = 4.89 M2 74.80 2.635 0.0 10.000 30.520 to 120.0 0.0 0.0 0.0 M3 157.92 00671 0.0 10.000 0.671 Vel = 9.29 M3 0.0 2.635 0.0 10.000 31.191 to 120.0 0.0 0.0 0.0 M4 157.92 00671 0.0 10.000 0.671 Vel = 9.29 M4 78.23 2.635 0.0 10.000 31.862 to 120.0 0.0 0.0 0.0 M5 236.15 0.1412 0.0 10.000 1.412 Vel = 13.89 M5 3.69 2.635 0.0 10.000 33.274 to 120.0 0.0 0.0 0.0 M6 239.84 0.1453 0.0 10.000 1.453 . Vel= 14.11 M6 3.67 2.635 0.0 10.000 34.727 to 120.0 0.0 0.0 0.0 M7 243.51 0.1494 0.0 10.000 1.494 Vel = 14.33 M7 4.89 2.635 0.0 10.000 36.221 to ' 120.0 0.0 0.0 0.0 M8 248.4 0.1551 0.0 10.000 1.551 Vel = 14.61 M8 7.08 2.635 0.0 10.000 37.772 to 120.0 0.0 0.0 0.0 M9 255.48 0,1633 0.0 10.000 1.633 Vel = 15.03 M9 10.02 2.635 0.0 10.000 39.405 to 120.0 0.0 0.0 0.0 MIO 265.5 0.1754 0.0 10.000 1.754 Vel = 15.62 M10 13.69 2.635 0.0 10.000 41.159 to 120.0 0.0 0.0 0.0 Mil 279.19 0,1925 0.0 10.000 1.925 Vel = 16.43 Mil 18.08 2.635 0.0 10.000 43.084 to , 120.0 0.0 0.0 0.0 M12 297.27 0,2161 0.0 10.000 2.161 Vel = 17.49 M12 23.20 2.635 0.0 10.000 45.245 to 120.0 0.0 0.0 0.0 M13 320.47 0.2484 0.0 10.000 2.484 Vel = 18.85 M13 29.07 2.635 0.0 10.000 47.729 to 120.0 0.0 0.0 0.0 M14 349.54 0.2917 0.0 10.000 2.917 Vel = 20.56 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 11 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn M14 35.72 2.635 0.0 10.000 50.646 to 120.0 0.0 0.0 0.0 M15 385.26 0.3492 0.0 10.000 3.492 Vel = 22.67 M15 43.16 2.635 0.0 10.000 54.138 to 120.0 0.0 0.0 0.0 M16 428.42 0.4251 0.0 10.000 4.251 Vel = 25.21 M16 51.36 2.635 E 8.237 2.000 58.389 to 120.0 0.0 8.237 0.0 M17 479.78 0.5240 0.0 10.237 5.364 Vel = 28.23 M17 0.0 4.26 4E 52.668 99.000 63.753 to 120.0 0.0 52.668 0.0 M40 479.78 0.0505 0.0 151.668 7.661 Vel = 10.80 0.0 479.78 71.414 KFactor= 56.77 M20 77.04 2.635 0.0 10.000 30.100 to 120.0 0.0 0.0 0.0 M21 77.04 0.0178 0.0 10.000 0.178 Vel = 4.53 M21 83.55 2.635 0.0 10.000 30.278 to 120.0 0.0 0.0 0.0 M22 160.59 0.0692 0.0 10.000 0.692 Vel = 9.45 M22 0.0 2.635 0.0 10.000 30.970 to 120.0 0.0 0.0 0.0 M23 160.59 0.0692 0.0 10.000 0.692 Vel = 9.45 M23 83.04 2.635 0.0 10.000 31.662 to 120.0 0.0 0.0 0.0 M24 243.63 0.1496 0.0 10.000 1.496 Vel = 14.33 M24 -3.69 2.635 0.0 10.000 33.158 to 120,0 0.0 0.0 0.0 M25 239.94 0.1454 0.0 10.000 1.454 Vel = 14.12 M25 -3.66 2.635 0.0 10.000 34.612 to 120.0 0.0 0.0 0.0 M26 236.28 0.1414 0.0 10.000 1.414 Vel = 13.90 M26 -4.90 2.635 0.0 10.000 36.026 to 120.0 0.0 0.0 0.0 M27 231.38 01359 0.0 10.000 1.359 Vel = 13.61 M27 -7.08 2.635 0.0 10.000 37.385 to 120.0 0.0 0.0 0.0 M28 224.3 0.1284 0.0 10.000 1.284 Vel = 13.20 M28 -10.02 2.635 0.0 10.000 38.669 to 120.0 0.0 0.0 0.0 M29 214.28 0.1180 0.0 10.000 1.180 Vel = 12.61 M29 -13.69 2.635 0.0 10.000 39.849 to 120.0 0.0 0.0 0.0 M30 200.59 0.1044 0.0 10.000 1.044 Vel = 11.80 M30 -18.07 2.635 0.0 10.000 40.893 to 120.0 0.0 0.0 0.0 M31 182.52 0.0877 0.0 10.000 0.877 Vel = 10.74 M31 -23.20 2.635 0.0 10.000 41.770 to 120.0 0.0 0.0 0.0 M32 159.32 0.0682 0.0 10.000 0.682 Vel = 9.37 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc Page 12 Nortek - T.I. ECOH - PIR/FLEX Open Date 1-26-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c'.or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn M32 -29.08 2.635 0.0 10.000 42.452 to 120.0 0.0 0.0 0.0 M33 130.24 0.0469 0.0 10.000 0.469 Vet = 7.66 M33 -35.72 2.635 0.0 10.000 42.921 to 120.0 0.0 0.0 0.0 M34 94.52 0.0260 0.0 10.000 0.260 Vet = 5.56 M34 -43.16 2.635 0.0 10.000 43.181 to 120.0 0.0 0.0 8.662 M35 51.36 0.0084 0.0 10.000 0.084 Vet = 3.02 0.0 51.36 51.927 KFactor= 7.13 M40 479.78 4.26 T 26.334 2.000 71.414 to 120.0 E 13.167 39.501 7.796 TOR 479.78 0.0505 0.0 41.501 2.096 Vet = 10.80 TOR 0.0 4.26 E 13.167 18.000 81.306 to 120.0 0.0 13.167 0.866 BOR 479.78 0.0505 0.0 31.167 1.574 Vet = 10.80 BOR 0.0 4.26 0.0 2.000 83.746 to 120.0 0.0 0.0 1.299 UG1 479.78 0.0505 0.0 2.000 0.101 Vet = 10.80 0.0 479.78 85.146 KFactor= 51.99 UG1 479.78 4.1 E 14.534 8.000 85.146 to 140.0 0.0 14.534 0.0 UG2 479.78 0.0458 0.0 22.534 1.032 Vet = 11.66 UG2 0.0 4.07 2E 31.864 25.000 86.178 to 150.0 0.0 31.864 0.0 UG3 479.78 0.0417 0.0 56.864 2.373 Vel = 11.83 UG3 0.0 4.1 E 14.534 6.000 88.551 to 140.0 0.0 14.534 -2.166 BF1 479.78 0.0458 0.0 20.534 0.941 Vet = 11.66 BF1 0.0 4.026 2E 20.0 6.000 87.326 to 120.0 0.0 20.000 6.000 * Fixed Loss = 6 BF2 479.78 0.0665 0.0 26.000 1.729 Vel = 12.09 BF2 0.0 4.1 E 14.534 6.000 95.055 to 140.0 0.0 14.534 2.166 UG4 479.78 0.0457 0.0 20.534 0.939 Vet = 11.66 UG4 0.0 4.07 6E 95.593 25.000 98.160 to 150.0 0.0 95.593 0.0 UG5 479.78 0.0417 0.0 120.593 5.034 Vet = 11.83 UGS 0.0 9.42 2E 49.22 1240.000 103.194 to 150.0 T 55.931 110.744 0.0 SCR 479.78 0.0007 G 5.593 1350.744 0.946 Vel = 2.21 500.00 Qa = 500.00 979.78 104.140 KFactor= 96.01 Computer Programs by Hydratec Inc. Revision: 50.52.1 C" C CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday AvenuO - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Nortek SRU: (Assigned upon plan submittal) PROJECT ADDRESS: 5919 Sea Otter Place CITY: Carlsbad PHONE: ( 858) 513-4949 (Western Fire Protection) FAX NUMBER:( 858 ) 513-1322 Largest Building (ft. 2): 80,000 Sprinkled? YES Construction Type: Concrete SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): North end of Sea Otter Place. TEST INFORMA T1ON IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 126 PSI Hydrant Number (if applicable): H20747 Elevation of test: 410 Feet Main Size: 10 INCH Pressure Zone: 700 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow:6PM Total Flow: 3,425 GPM Residual Pressure 113 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in the vicinity of the fire in excess of 8,000 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 3,425 gpm. There was no specific requestforfireflowfrom the Client or Fire Department. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:_______________________________________ Title/Or P_iectManager Date: 12/1/2017 N Legend 41 w..Hydrant ii Pipe V ZONE '•'t"••*q• -700 C • 1; 10 C Fire Flow Test Location H20747 [Project Site io" #4 8. 10• Ill WI WiMi.I 30. Al II oP.jP "fr 30. — 30 • ¶tCP0 _ 5919 Sea Otter Place - Fire Flow Analysis MCS Mission Consulting Services WATER SYSTEMS SPECIALISTS 9418 Mast Blvd. Santee, CA 92071 (619) 851-5178 BUM: Western Fire Protection Attn: Jason Nichol Invoice Invoice #: 00324 invoice Date: 1211/2017 Due Date: 1/1/2018 PrOject: 100009 Carlsbad Fire Flows P.O. Number: Date Description Amount Total Due $200.00 Page 1 of 6 NIIQ 4 ® MICROFAST® QUICK l:II[*.,yy RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking MicrofaW Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 LPCB Approved (( CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 *C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 ' IIII1G® MICROFAST® QUICK l:II[1..yy RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2fl ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking MicrofastO Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 MICROFAS QUICK %liI(IF1G® P RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 BIb I U o or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 oF (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 N iIIF1i 4 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vukingcorp.com Visit the Viking website for the latest edition of this technical data page www vikinggroupinc corn Approval Chart I (UL) Temperature KEY The Viking Microfast Quick Response Fin' h Pendent Sprinkler VK302 A'iX.Escutcheon (if applicable) Maximum 175 Psi (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Ap'pro.'aié' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number1 NPT BSP U.S. metric2 inches mm cULus4 VdS LPCB (' 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, 02, C2X Al A1Z, B1Y D1Z, dY - - 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 -- -- -- -- - D3 21354 VK302 Pendent -- 15mm 56 80.6 2-1/4 58 - -- -- - - D3 NOTICE - Product Below lability (Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, 02, C2X -- -- - - - 11 18021 VK302 Pendent 1 1/2" 15 mm 1 5.6 1 80.6 2-1/4 58 AIX, B1Y Al I AiX, B1Y I D1X, dY8 Dlx, dY9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 "C), 175°F 1 - Brass, Chrome, White X- Standard surface-mounted escutcheon or the (79 "C), 200 OF (93 "C), 286 OF (141 "C) Polyester56, Black Polyes- Viking Micromatic® Model E-i Recessed Escutcheon B - 135 OF (57 "C), 155 OF (68 "C), 175 OF ter56 Y - Standard surface-mounted escutcheon or the (79 °C), and 200 OF (93 °C) 2 - ENT' Viking Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 OF (68 °C), 175 OF (79 °C), and 3-Chrome matic® Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the O - 155 OF (68 °C), 175 OF (79 °C), 200°F Viking Microfast5 Model F-i Adjustable Escutcheon (93 °C), 286 OF (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F033314 17.10.05 Rev 17.2 Page 5 of 6 NIKIIs16® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfase Quick Response Pendent Sprinkler VK302 AIX4- Escutcheon appticable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric' Inches mm 12979 VK302 Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 .)tLdE - Producl:L Limited Availability 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, 131Y, D2X, C2 18021 VK302 I Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 1C), 200 OF Viking Micromatic3' Model E-I Recessed (93 °C), 286 OF (141 °C) Approved Finishes Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 1C), and 1 -Brass, Chrome, White Polyester4, Y - Standard surface-mounted escutcheon or the 200 OF (93 °C) and Black Polyester4 Viking Microfast® Model F-I Adjustable Escutcheon, C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic® Model E-1 OF (141 °C) or E-2 Recessed Escutcheon D - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-1 Adjustable Escutcheon Footnotes I Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) The Viking Microfase Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 1-1/8" (29 mm) Mm. 1-3/4" (45 mm) Max. !ling Opening Size: 6" (59 mm) minimum :" (64 mm) maximum Page 6 of 6 N II(IIIG MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 4 Ceiling Opening Size: 1/2" - 2-5/16" (59 mm) minimum (15 mm) .- r I21I2 (64 mm) maximum NPT 2-1I8"'I _________ (54 mm) (38 (h12) Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 6 MICROFAST® QUICK RESPONSE HORIZONTAL II I1G SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2020 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4" (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F / 57 °C = A, 155 °F / 68 °C = B, 175 °F / 79 °C = D, 200 °F / 93 °C = E, and 286 °F /141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) **A 1/2" ratchet is required (not available from Viking). Form No. F_060914 17.10.05 Rev 17.1 Replaces form F_060914 Rev. 16.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 MICROFAST® QUICK RESPONSE HORIZONTAL NJIKJNG* SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. '4T1TTT1 21475 • Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F060914 17.10.05 Rev 17.1 Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. Page 3 of 6 MICROFAST® QUICK RESPONSE HORIZONTAL N11KINGGJ4 SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient U 0 Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. ** A 1/2" ratchet is required Step 2: Carefully press the wrench onto the (not available from Viking) sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers Form No. F060914 17.10.05 Rev 17.1 Page 4 of 6 MICROFAST® QUICK "SI I F(I F16 RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 Finsh For Light or Ordinary Hazard Occupancies AiX 4- Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Deflector must be located 4" to 12" (102 mm to 305 mm) below the ceiling. Listings and Approvals3 Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length (Refer also to Design Criteria on page 43x.) Number Style NPT BSP U.S. metric2 Inches mm cULus4 LPCB 12997 VK305 HSW 1/2" 15 mm 5.6 80.6 2-11/16 68 AlY, B1X, - -- - 19782 VK305 HSW 1 1/2" -- 5.6 80.6 2-11/16 68 -- - -- E3 )t(.I J7T7I7l Availability Local Viking z 12121 VK305 HSW 1/2" 15 mm 5.6 80.6 1-11/16 68 1 AlY, B1X, -- -- -- Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 "C), 175 W - Installed with standard surface-mounted escutcheons "F (79 "C), 200 "F (93 "C), and 286 "F Approved Finishes X - Installed with standard surface-mounted escutcheons or (141 "C) 1 - Brass, Chrome, White Poly-ester' 6, the Viking Microfast® Model F-i Adjustable Escutcheon, B - 135 "F (57 "C), 155 "F (68 °C), 175 "F and Black Polyester56 or recessed with the Viking Micromatic5 Model E-1, E-2, (79 "C), and 200 "F (93 "C) 2 - ENT5 or G-1 Recessed Escutcheon C - 155 "F (68 "C), 175 "F (79 "C), 200 "F Y - Installed with standard surface-mounted escutcheons or (93 "C), and 286 "F (141 "C) 3 - Chrome the Viking Microfast® Model F-i Adjustable Escutcheon D - 155 "F (68 "C), 175 "F (79 "C), and 200 Z - Installed with standard surface-mounted escutcheons or "F (93 "C) recessed with the Viking Micromatic Model E-i E - 155 "F (68 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2Metnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate with the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F060914 17.10.05 Rev 17.1 Page 50f6 MICROFAST® QUICK J I FI I16 RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) - Temperature KEY Quick Response Sidewall Spnnklers ,u Fn A1XI— Escirtcheon (it ppIiciab1e) Maximum 175 PSI WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals'-' NPT BSP U.S. metric2 Inches mm Number' (Refer also to Design Criteria below.) 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE T I:4Ifi7flV 1TTILocal !711k.Jiil 12121 VK305 1/2" 15mm 5.6 80.6 2-11/16 1 68 1 A1Y,B1X Approved Temperature Ratings Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175 X - Installed with standard surface-mounted escutcheons or the Viking °F (79 °C), 200 °F (93 °C), and 286 Approved Finishes Microfast® Model F-i Adjustable Escutcheon, or recessed with the °F (141 °C) 1 - Brass Viking Micromatic® Model E-1, E-2, E-3, or G-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 Y - Installed with standard surface-mounted escutcheons or the Viking °F (79 °C), and 200 °F (93 °C) Microfast® Model F-I Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2Metnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. DESIGN CRITERIA - _FM (Also refer to Approval Chart 2 above.) FM Aonroval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM, Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F060914 17.10.05 Rev 17.1 2-3/4" (68 mm) 2-1/8" (54 mm) Minimum 1-7/8" 2-5/8" (67 mm) Maximum Page 6 of 6 MICROFAST® QUICK "1 I KI IsIG l:IIE•'yM RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Wall Opening Size: Installed with a Standard 2-5/16" (58.7 mm) minimum 1/8" Surface-Mounted 2-1/2" (63.5 mm) maximum Escutcheon jure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Installed with a Microfast Model F-I Adjustable Escutcheon Escutcheon Minimum Minimum 1-5/8" 1-3/4" (41 mm) (45 mm) 2-1/8" Li (54 mm) Ii 2-1/8" 454 mm) 2-1/4" 2-5/8" (57 mm) (67 mm) Maximum Maximum Wall Opening Size: Installed with the Installed with the 2-5/16" (58.7 mm) minimum Micromatic Model E-1 Threaded Model E-2 2-1/2" (63.5 mm) maximum Recessed Escutcheon Recessed Escutcheon Figure 4 Sidewall Sprinkler VK305 Dimensions with the Model E I and E 2 Recessed Escutcheons Form No F_060914 17 10 05 Rev 17 1 Replaces form F 060914 Rev. 17.1 (Replaced wrench 10896W/B with 21475M/B) - - AL/iTAuilder 2012 PRODUCT CATALOG www.itwbuildex.com 800-BUILDEX TABLE OF CONTENTS Sammys® for Wood ..........................................................................................................................4 Sidewinder® for Wood.......................................................................................................................5 Sammys Swivel Head for Wood......................................................................................................5 Sammys® for Steel............................................................................................................................6 Sidewinder® for Steel........................................................................................................................7 Sammys Swivel Head for Steel.......................................................................................................7 SammyX-Press® ............................................................................................................................... .8 SammyX-Press Sidewinder ............................................................................................................8 SammyX-Press SwiveIT ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete...................................................................................................................10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head for Concrete................................................................................................11 Concrete/Wood Installation Kit........................................................................................................11 SammysToggleT ............................................................................................................................12 CeilingScrews.................................................................................................................................12 Dektite® Pipe Flashing.....................................................................................................................13 SpeedyPole Tool 'TM..........................................................................................................................13 SpotRite Level ' .............................................................................................................................. 13 Approvalsand Listings ....................................................................................................................14 SpecialNotes ..................................................................................................................................15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. BUildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. Ii1STALLATJON STEPS 1I[eftNTO WOOD & STEEL I1NSTALLAT1ON STEPS :[.h4.1uiINTo WOOD & STEELI Insert the appropriate nut driver into a 3/8" or 1/2" portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, (hen add retainer nut and torque to 20 foot tbs. for maximumpullout in purlin steel. rirrrt' Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", MIO, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. ............ [INSTALLATION STEPS -INTO CONCRETE: 1 Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place lip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS -I']M'1if INTO CONCRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW (red) nut driver (p/n 81149 10) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. NO wl~j01 r- il"IMMMIii jlm~Mmm jq I;= a Iii mill SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYS® FOR WOOD Not less than 2 nominal width Not less than 3" nominal thickness (2-112') (depth or side of vertical member) Wood No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Doable Shei Ceiling Wood * Watch a video demonstmtion at www.itwbulldex.com i - #14 Black Nut Driver Part # 8113910 I #14 SW Red Nat Driver Part #8114910 - 1/4 8002957 GST 100 1/4 x 1' 670 25 125 I 1/4w 8003957 GST 200 1/4 x 2 1760 (Fir) 25 1 jIj 3/8 8007957 GST 10 1/4 x1" 300 25 125 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 ~25 3/8" 8068925 GST 20-SS 1/4x2" 1760 (Fir) 850 25 125 EI 3/8" 8009925 GST 25-380 3/8x2-112" 2113 (Fir) 1500 25 125 3/8' 8010957 GST 30 1/4x3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4 x 3 2060 (Fir) 25 - 125I - 1/2' 8013925 GST2 1/4x2" 1760 (Fir) 25 125 3_1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 ] V QwftMCTUvEO5.5A Or SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free, Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Black V#14 Nul Driver - 3/8° 8139957 SH-GST2O 1/4 x 2 1257 (Fir) 1050 1475 Part #8113910 1903 Dim. Lumber 3/8"" 8269957 SH-GST/CST 20 5/16 x 1-3/4 1500 1406 @ 45°off vertical Dim. Lumber 903 Dim. Lumber 1/2" 8303957 Sl-l-GST/CST 2.0 5/16 x 1-314" 1406 @ 45°off vertical Dim. Lumber - * May require pre-drilling; consult joist manufacturer. #14 SI-f Orange Nut Driver Part #8273910 25 125 25 125] 25 125 5"- W4JZMYS° Not less than 2" nominal width (1-1/2) up to 3-1/2" pipe: not less than 3 (2-1/2") nominal width 4 & 5 pipe I I Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. _____________ No pre-drilling required. 7Floor Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. ,"Waw a video dernonofrarion www.itwbulldex.com) - 1/4" 8019957 3/8" 8020957 3/8" 8021957 -F :10Z 3/8" 8073925 .c. 3/8" 8022925 #14SWRed LL 3/8" 8023925 Nut Driver Part #8114910 * May require pre-drilling; consult joist manufacturer. SWG 200 1/4 x 2 1725 (Fir) 25 125 SWG 10 114x1" 622 (Fir) 300 25 125 SWG 20 1/4 x 2 1725 (Fir) 1050 25 125 SWG 20-SS 1/4 x 2 1725 (Fir) 850 25 125 SWG 25-380 3/8 x 2-1/2 2249 (Fir) 1500 25 125 SWG 30 1/4 x3 1884 (Fir) 25 125 WONJOW serums Eliminates distortion of threaded rod. "Accommodates up to 3 /" x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. SAMMYS® FOR STEEL J-- 's —Z 1 (IM Wawa 3 ? , , Pa" a a jk I! F' Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the sci-ewgun should be a minimum of 6 amps and have an RPM range of 0-2500. Manufactured in the U.S.A. )Watch wwwa videodtwbuildex.com demonst,alion a'"t j i #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part #8114910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (Ibs) FM Test Min Load (lbs) Thick Max Thick Box Qty Case Qty I 1/4" 8024957 DSTR 100 * 1/4-20 xl" TEKS 3 1510 (20 ga.) .036-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14_x_1" TEKS_3 446_(20_ga.) .036'-20 ga 3/1&25 125] 1/4" 8026957 DST 150 1/4-14 x 1-1/2' TEKS 3 970 (16 ga.) 036-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8030957 TEK 500 12-24 x 1-1/2' TEKS 5 3125 (3/16") ,188"-3/16" 1/2" 25 125 8038957 DSTR 1 1/4-20 xl" TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 go 3/16" 25 125 1 - <C 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060-16 ga. 1/2" 25 125 8039957 DSTR 516*5/1618_x1-1/4" TEKS32200 (20ga.)15001475.036"-20ga3/16"25125 3/8" 8040957 DST 10 1/4-14 xl" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8077925 DST 10-SS 1/4-14 xl" TEKS 3 .036"-20 ga 3/16" 25 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036-20 ga 3/16 25 125 970 (16g3.) 3/8" 8042957 DST 20 1/4-14 x 2" TEKS 3 446 (20 .036-20 ga 3/16' 25 125 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 4 3/8" 8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16') 1500 1475 .125"-1/8" 3/16" 25 125 3/8' 8046957 _TEK5012-24x1-1/2" TEKS 53125(3/16")15001475.250-1/4"1/2"25125I 1/2" 8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 .188-3/16' 1/4" 25 125 1/2" 8033925 DSTR 1.0 * 1/4-20 xl' TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 1251 1/2" 8034925 DSTR 5.16 * 5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.) .036"-20 ga 3/16' 25 125 1/2" 8035925 DST 5.16 5/16-18 si-i/i" TEKS 3_1500_(3/16")_ .125-1/8" 3/16" 25 125 1 1/2" 8036925 TEK5.0 12-24x 1-1/2" TEKS S 3125 (3/16) .188-3/16" 1/2" 25 125 "Includes retaining nut \I/ (l1l1m. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sale installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins eoaajFvcrunss use. free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. MMYS° N/)JIItdLf Oil t'H" Made with Tekse self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Watch a ann demonnt,nlion at I Manufactured in the U.S.A. WWW.ifWbulldex.comj i- #14 SW Red Nut Driver Part #8114910 114" 8047957 SWD 100 1/4-14 ii I" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 II 1/4" 8049957 SWDR 100 114-20 xl TEKS 3 1900 (2o ga.) .036"-20ga3116" 25 125 318" 8050957 SAID 10 1/4-14 x 1TEKS 3 1477 (16 ga.) .060"-16 ga3116"25125 3/8" 8080925 SWD 10-SS 1/4-14 xl" TEKS 3 1477 (16 ga.) .060-16 ga 3/16" 25 125] 3/8" 8052957 SWD 20 1/4-14 x 2' TEKS 3 1477 (16 Qa.) .060-16 as 3/16" 25 125 3/8 8054957 SWDR 1-1/2 * 12-24 x 1-1/2 TEKS 5 2375 1500 1475 .188-3/16" 1/2" 25 125 15001475.036"-20ga3/16__25125 3/8' 8057957 SWT 15 12-24x 1-1/2" TEKS 5 2375(3/16) .188-3/16' 1/2" 25 125 "Includes retaining nut '1 #14 Black Nut Driver - Part #8113910 I #14 SH Orange Nut Driver Part #8273910 Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purtin; allows threaded rod to hang plumb. "Allows 17° deflection from vertical. Manufactured in the U.S.A. .3b5 (111 steel vertical) 3/8" 8268957 SH-TEK 50 12-24n 1-3/4" 1306 (45° off Vertical) 1500 (Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281 (3/16' HSS) 850(45" off Vertical) 2-1/2" 1585 (3/16" HSS 45" off Vertical) 2368(1/2" steel Vertical) 1/2" 8270957 SH-TEK 5.0 12-24 x 1-3/4" 1306(45° off Vertical) 3/16" 1/2 25 125 TEKS 5 2281 (3/16" HSS) 1585 (3/16" HSS 45° off Vertical) Toes not comply with ROHS requirements /Includes retaining nut SAMA1'( AX_PRESS Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press It5 Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Manufactured in the U.S.A. , watch a video demonstration at 1/4' 8181922 XP 200 Sammy 1146 (22 ga) 185 (Luminaire) .027' .125" 25 125 Metal Deck X-Press 200 250 (Luminaire) .056' 850 (2W Pipe) .027" 185 (Luminaire) 027' 940 (2' Pipe) .029' 3/8 8150922 XP 20 Sammy X-Press 20 1146(22 ga) 250 (Luminaire) 056' 1475 (4' Pipe) .104" .125' 25 125 Metal Deck 283 (Conduit & Cable) .029' 1500 (4" Pipe) .060' 185 )Luminaire) .020" 940 (2" Pipe) .020' 25 125 Purliri 3/8' 8153922 XP 35 Sammy 1783 (16 gal X-Press 35 250 (Luminaire) .056" 1475 (4" Pipe( 104' 416 (Conduit & Cable) .959' Pre-Pour Structural Concrete@ 3000 psi Metal Deck (Pre-Pour) 1 Sammy 1146 (22 ga) 850(2% Pipe) 25 125 3/8' 8150922 XP 20 X-Press 20 Post-Pour Range It LWCC 35 PCF Metal Deck j (Ibs/ft") (Post-Pour) Pre-Pour Structural Concrete @3000 pet Pout-Pour Range II LWCS 35 PCI' (Ibs! ft) 11 1 The Sammy X-Press Sidewinder expands to • Less jobsite material needed. provide horizontal attachment in: - 16 ga - 3/16" steel - purlin, tubular steel. • No retaining nut required. Installs in seconds with Sammy X-Press It® Tool, Provides design flexibility. saving time & installation costs. Manufactured in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; ie. metal root (SWXP) I deck, tubular steel, or vapor barrier fabric. oWatch a 'ides demonstration at 1 www.itwbuildex.comJ Sidewinder — 1-1 1 11.1 3/8" 8293957 SWXP 35 X-Press 35 1798 (16 ga) 80 (Luminaire) .059" .125" 25 125 Parlin (onvit&Cable)__________________________________________ QR1 DUSA V AJ'yc® I The Sammy X-Press Swivel allows you Less jobsite material needed. to hang plumb in extreme roof pitches: - 89 in z-purlin No retaining nut required. -45" in metal deck for 12/12 pitch IF OR Provides design flexibility. AREME • Installs in seconds with Sammy X-Press It° Tool, OR saving time & installation costs. Manufactured in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof Watch a video demoosfrat ROOc pCIS deck, tubular steel, or vapor barrier fabric. JlwrwJtwbulldex.comJ 750(2" Pipe) 170 Vertical (Luminaire) Swivel "> 31 8294922 SXP 20 X-Press 1061 (22 ga Vert) 80 @45" (Luminaire) .029" 635 (2" Pipe) .029" .125" 25 125 Metal Deck 829 (45- Off Vert) 283 Vertical (Conduit & Cable) 233 @45" (Conduit & Cable) 1250 (3-1/2' Pipe) Swivel 1675 (16 ga Vert) 250 Vertical (Luminaire) 4- S' 318" 8295922 SXP 35 X-Press35 1558 ( Off Vert) 500 Vertical (Conduit& Cable) 635 (2" Pipe) .029" .125" 25 125 Purlin 333 @ 89" (Conduit & Cable) 1/2" 8272957 SXP 2.0 Swivel 1061 (22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829 (45" Off Vert) Swivel 1675 (16 ga Vert( 112" 8271957 SXP 3.5 X-Press 3.5 1558 (89" Off Vert) .060" .125" 25 125 Purlin 7~ Vt'~l AM 1!kl~R 4 OL The Sammy X-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) Manufactured in the U.S.A. Watch a widen demonstration a7\ www.itwbuildex.comj 8194910 8152910 "Tool Includes; Sleeve, Oil Receiver, Hex Wrench, and 25/64" Drill Bit. -,1*t•lI•Iu•1,- Universal X-Press It Tool XPDB 25/64" Drill Bit 1 SAMMYS FOR CONCRETE Easy two step process (Drill hole & drive Sammys concrete anchor). 1/4' pre-drilled pilot hole required. Concrete Installation Tool available for a one tool installation process. Manufactured in the U.S.A. II - ~ 41~ I Watch a video demnnst,atioo www.itwbulldex.comJ #14 Black 1/4 8058957 CST 200 5/16 x 1-3/4 2400 25 125 Nut Driver Part# 8113910 [?!! f 3/8° 8059957 CST 20 5/16x 1-3/4° 2400 1475 25 125J #14SW Red 3/8" 8145925 CST 20-SS 5/16 x 1-3/4 2400 25 125 Nut Driver t 1 1/2" 8060925 CST 2 5/1601-3/4° 2400 25 125 Part # 811490 Tested in 3000 PSI concrete I 0 • Easy two step process (Drill hole & drive Sammys 0 T so concrete anchor). Y4" pre-drilled pilot hole required. t* 04 i — :::::h:U Concrete Installation : available for a one tool Watch a den dem foliO! 0 at www ,twbu,Idex.com I'M Test Box Case Size Number Descriptions JApprovals Rod Part Model Screw Load ! -[ LHORIZONTAL MOUNT 1/4° 8062957 SWC 200 5/16 x 1-3/4" 2450 25 125 3/8° 8061957 SWC20 5/16x 1-3/4° 2450 1475 25 125 j #14SW Red * Tested in 3000 PSI concrete Nut Driver Part# 8114910 ARk V (lIIuII SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins wo MiOurAccuRED c.n.n free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. LA "'jiMYS0 --ff A& ff - - - ~ - - -- § Installs vertically and swivels up to 89° in wood & concrete structures. Eliminates distortion of threaded rod. 1/4" pre-drilled pilot hole required. 'Concrete installation tool available for a one piece installation process. Manufactured in the U.S.A. - 3/8" 8269957 SN-GST/CST 20 5/16 x 1-3/4' 1/2' 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" #14 SH Orange Nut Driver Part #8273910 - Note: UL Listed for wood - see page 5 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 25 125 1636 @ 45°off vertical in 6000 psi concrete 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 25 125 1636 @ 45°off vertical in 6000 psi concrete * Tested in 3000 PSI concrete (b) (e) (h) () (d) (h) Aer am Part Number II Each Oty L. 8110_ Concrete Installation Kit (a) - - t°ii incivaes me iouowingitems: 8113910 #14 Black Nut Driver (b) 1 8114910 #14 SW Red Nut Driver (c) 1 8116910 #25O Bit (1/4")(d) 1 8117910 SIDS Bit (1/4°) (e) 1 8118910 7/32 Wood Bit (f) 1 8120910 HEX 250 Bit Receiver (1/4') (g) 1 8098910 SL 250 Sleeve (h) 1 1 8121910 SIDS B25O Bit Rec(V4")° 1 .j 'Only sold separately - not included in kit. ACCESSORIES +ct J k Pre-Cast Hollow Core Concrete 1 Pre-drill a 5/8" hole with a regular drill or hole saw. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. When bolt is secure and nut driver spins free, stop drill motor and remove. SST screw is now ready to receive 1/4", 3/8", or Metric all thread rod or bolt stock. Rod Size Part Number Model 7I.Tt 1/4" 8063925 SST 300 1/4 x 3" 3/8" 8064925 SST 30 1/4 x 3" #14 Black Nut Driver Part #8113910 450 (Lath & Plaster) 25 125 404 (2 Layers 5/8 Rock) 450 (Lath & Plaster) 25 125 404 (2 Layers 5/8 Rock) 3/16" eyelet to accommodate common wire size. ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. Approvals Substrate Part Model Point Description Overal Total Ultimate Max ICC Test Box Case Number Length Pullout (lbs) Gauge Load (Ibs) Qty Qty 14 r ICC STEEL 8107957 CWSD 1* Teks 1/4 xl" 2" 472 (20 ga) l6ga. 170(20ga.)j_jJ 1 1 1 ICC STEEL 8190957 CWSD 15" Gimlet 1/4 x 1-1/2" 2-314" 472 (20 ga) 20 ga. 170 (20 ga.) 25 125 WOOD Teks 1393 (Fir) 1_J L [lCC STEEL 8108957 CWSD 2* Teks 1/4 x 2" 3-1/4" 472 (20 ga) 16 ga. 170 (20 ga.) 25 125 1 CWIT ICC 8110910 CWIT Installation Tool 1 Installation Tool Does not comply with ROHS requirements Part # 8110910 CTAKHTff I k -4--DEK11TE STAY UP TO 3 CODE! with a quicker, more efficient way - ' H9(E to flash your refrigeration/freezer units. INSULATED FREEZER STRUtTUIE "Complies with NFPA 13 Code Changes. Flashing for dry pendant sprinklers subject to extreme temperature changes. One piece construction is easy to install. Pipe diameter markings ensure accurate fit. EPDM temperature range of -65°F to +250°F. j40019110 Mini 1/4"- 1-1/8" 3-1/2" 1-3/4" 20 j 4003910 1 1/4-2" 4-3/4" 3 10 [ 4004910 2 1-3/4" - 3-1/4" 6-1/4" 4" 10 Adaptor Plug (a) Socket Driver for SAMMYS (b) Socket Driver for Ceiling Wire Screws (c) Socket Driver for 1/4" Standard Nut Drivers (d) Stud Plug for Viper or Ladd Powder Actuated Attachment (e) (Items not sold seperately) c'Wavh a video demonstration at www.itwbulldex.com The Pole Tool and Universal Socket Kit provide easy and safe installation for: Sammys - Jack Chain Threaded Rod - Wire Pencil Rod - Screws Ceiling Screws Ideal for retrofit and hard-to-reach projects in wood and steel. 8123910 Pole Tool 6' 8124910 Pole Tool 12(4-12) 1 8125910 Pole Tool 18(6'- 18) 1 8126910 Pole Tool 24'(8'- 24) 1 FSpeedy TPole Tool Installation (specity choice when ordering pole tool) 8127910 Semmys Socket Driver 1 8128910 Ceiling Wire Socket Driver for wire and chain 1 8129910 Universal Pole Tool Socket Kit 1 PartNumber Model Ea. Qty 8130910 Spot Rite Level 1/2", 3/4", and 1" threading Magnetic strip for ease of use "Pocket Sized Lightweight 3-vial design for measurement of 00, 450 and 900 angles - Er APPROVALS L8007957 GST 10 3/8' Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST 20 3/8" Vertical 2-1/2" 850 1-1/2" 4" - 1475 1-1/2" 8068925 GST 20-SS 3/8" - Vertical - 2-1/2" 850 1-1/2" [0957 GST 30 3/8 Vertical 4 00 11/2 -4- 8009925 GST 25-380 3/8" Vertical 4" 1500 1-1/2" [82"7T25-380 - 3/8" Horizontal 3-1/2"-4"" 1500 - 71/2" - - - - - - 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3""" 1050 1-1/2" [i5 SWG 2o SS 3/8 Horizontal 21/2 850 11/2 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 1-1/2" - 850 [69957 _SH-GST/C51203/8°_45"Angle off Vertical 82 4" i500_i-1/2_ 8139957 SH-GST 20 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" L8038957..DSTR 1 3/8" Vertical 1500 - M35" 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" r03-9957 IDSTR 516 iw VI 7 037 T 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" [6957T a Vertical 4" 1500 250 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" [8o557 SWDR 516 &Honzontal 4" - - 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4 1475 .060" 8137957 SH-DSTR 1 3/8" -~7* Angle off Vertical 4 1500 - 035 - 1475 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 850 ___ _, glVj ____L 1S.,9P . L8150922 3/F Vertical 850 -. .02 __. " 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 4 1475 r2T' SXP 2o 3/8" - - Vertical orupto45 750 .027" 2" 635 1029" 8295922 SXP 35 3/8" Vertical or up to 89" 37/2" 1250 .060" 2" 635 .029" r8293957 ' SWXP 35 3/8" - Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE - PIPE HANGER 059957 _CST 20 3/8" - Vertical ".J475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 E922"rXP2o 3/8 Vertical 2-1/2" 850 Pre Pour Structural ©3000p_________ 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Rance II LWC 5 35 PCF (lbs/ft3) 8153922 XP 35 8181922 XP 200 8294922 SXP 20 [8295922 SXP 35 8293957 SWXP 35 185 .027" 3/8 Vertical 250 .035" 185 .027" 114 Vertical 250 .035" . Vertical 170 .0271' 3/8" 80 .027" Vertical 250 It .060" 3/8" 90" -.--80-- .060" 3/8" Horizontal 80 .060" 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit SXP 20 3/8 Verbcal - 283 - 027 Max 4 trade size EMT, RMC, and tMC& 5 trade size nd PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit r 8293957 - SWXP 35 3/8 Honzontal 060 Max 4 trade sizeEMT&6 trade sze RMC MC and rigid PVC conduit 8149957 CZ2000 1/4 or 3/8 Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies W/ NEC Standards Gauge No._-- 22ga._ 209a. Nominal Decimal Equivalent .030" .036" SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size is wood timber or blot allowed by UL is 4" ""SWO 20 Mdmum pipe size in composite wood joist allowed by UL is 2-1/2" 18 9_.. . _3/16" II4" .048" .060" .075" .105" .125" .188" .250" UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by IJL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press' was completed using (.030') or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments7 For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7132" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAJNEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM Approvals UL and FM reports are available at www.itwbuildex.com ALSO LIRWO AR 100000 FOR LOIIDJA000 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information MARLUFACTURED U.S.A. Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 - - BUILDING IDEAS THAT WORK FOR OVER 40 YEARS! QUALITY ,j At ITW Buildex we pride ourselves on serving the construction industry for over 40 years with innovative, quality products that help our customers save time and money. We are commited to our customers by providing world - class customer service and technical support. We are here to help! -. .-4 . \- -, ..—,. h.—.. \1 rnwRuiIdrn Snrnmys, Sammy S-Press , Sammy X-Press it. Sidewirrder. Sammy X-Press Swmei. Sammy X-Press Sidevarrder' Tapcorr Sammy Saddle-, Speedy Pole Tool'. Spot-Rite Level, Dektite'. Swivel Head"'. Sanrrnys 1eggle and Teds are trademarks of Illinois Toni Works. inc. DePute is a registered trademark stOcks Industries Pip Lid [ Product Data Sheet I Water - Grooved Products Pipe couplings and fittings Mech Tees - Threaded Approvals D ) UL CP [vds]< 09PROVED> I - D 1) The Rp1/2 and Rp3/4 outlet sizes are intended for direct connection to sprinklers onlys Nominal size Model Pipe OD mm 'Inch' Threaded Outlet Hole Dia +3.20 (+0.126) mm (inch) Part no. Approvals Weight DN Inch Red paint similar RAL Galvanized VdS 3000 LPCB FM UL kg (Ibs) 50 2 3J 60.3 (2.37) Rp1!2 38(1.50) 920025 920119 C - D D 0.7(l.53) Rp3/4 38(1.50) 920026 920117 C - D D 0.67(l.48) Rp1 38(1.50) 915519 915540 C - D D 0.73(l.6) Rp1.1/4 45(1.75) 915520 915541 C - D D 0.84(l.84) Rp1.1/2 1 45(1.75) 915521 915542 C - D D 0.86(l.89) 65 3 3J 76.1 (3.0) Rp1/2 38(1.50) 920027 920121 C - 0 D 0.96 (2.11) Rp3/4 38(1.50) 920028 920123 C - D 0 1.05 (2.30) Rp1 38(1.50) 915522 915543 C - D D 1.10 (2.43) Rp1.1/4 51(2.00) 915523 915544 C - D D 1.18(2.60) Rp1.112 51(2.00) 915524 915545 C - D 0 1.23 (2.72) 80 3 3J 88.9 (3.5) Rp1/2 38(1.50) 920051 920124 C - D 0 1.21 (2.66) Rp3/4 38(1.50) 920052 920125 C - D D 1.14 (2.51) Rp1 38(1.50) 915525 915546 C - D D 1.28 (2.71) Rp1.1/4 51(2.00) 915526 915547 C - D 0 1.31 (2.88) Rp1.1/2 51(2.00) 915527 915548 C - D D 1.35 (2.97) Rp2 64 (2.50) 915528 915549 C - D D 1.51 (3.32) 100 4 3J 114.3 (4.5) Rp1I2 38(1.50) 920053 920126 C - D D 1.59(3.51) Rp3/4 38(1.50) 920054 920127 C - D D 1.57 (3.45) Rp1 38(1.50) 915529 915550 C - D D 1.60 (3.53) Rp1.1/4 51(2.00) 915530 915551 C - D D 1.66 (3.67) Rp1.1/2 51(2.00) 915531 915552 C - D D 1.77 (3.91) 64(2.50) 915532 915553 C - D D 1.94 (4.27) 70 (2.75) 920055 920128 C C D D 2.06 (4.53) 3JS JR/4 70(2.75) 920056 920129 C - D D 1.68 (3.70) 3J 89(3.50) 920057 920130 C C D D 2.54(5.61) 125 5-1/2 139.7 (5.5) 3JS I 51(2.00) 915533 915554 C - D D 2.63 (5.79) Rp1.1/2 51(2.00) 915534 915555 C - D D 2.64 (5.83) Rp2 64 (2.50) 915535 915556 C - D 0 2.62 (5.77) Rp2.1/2 70 (2.75) 920058 920131 C C D D 2.80 (6.17) Rp2.1/2 70 (2.75) 920060 920132 - - D I D t 2.35 (5.19) > OD = Outside Diameter Working pressure: A = max. 12.1 bar (175 psi)! B = max. 15.5 bar (225 psi)/ C = max. 16 bar (232 psi)! D = max. 20.7 bar (300 psi)! E = max. 25 bar (363 psi)! F = max. 34.5 bar (500 psi)! - = no approvals a. © Viking S.A. I Z.l. Haneboesch I L-4562 Differdange/Nieclerkorn I www.viking-emea.com I Page 1/3 Product Data Sheet I Water Grooved Products Pipe couplings and fittings Mech Tees - Threaded Nominal size Model ,. )D mm 'Inch Threaded Outlet Hole Dia +3.20 (+0.126) mm (inch) Part no. Approvals Weight DN Inch Red paint similar RAL Galvanized VdS 3000 LPCB FM UL kg (Ibs) 150 6.1/2 3J 165.1 (6.5) Rp1.1/4 51 (2) 920061 920133 - - D D 2.75 (6.05) Rp1.1/2 51 (2) 920063 920134 - - D D 2.78 (6.12) Rp2 64(2.5) 920064 920135 - - D D 3.02 (6.65) Rp2.1/2 70 (2.75) 920065 920136 - C D D 3.17 (6.99) 3JS Rp2.1/2 70(2.75) 920067 820137 - - D 0 2.61 (5.75) 3J Rp3 89(3.5) 920070 920138 - C D D 3.54 (7.79) Rp4 114 (4.5) 920072 920139 - C D B 4.17 (9.19) US Rp4 114 (4.5) 920075 920141 - - D B 3.60 (7.94) 150 6 3J 168.3 (6.63) Rp1.114 51 (2) 915536 915557 C - D 0 3.11 (6.84) Rp1.1/2 51 (2) 915537 915558 C - D 0 2.97 (6.56) Rp2 64(2.5) 915538 915559 C - D D 3.28 (7.23) Rp2.1/2 70 (2.75) 920078 920142 C C D 0 3.57 (7.88) 3JS Rp2.1/2 70 (2.75) 920080 920143 - - D D 2.81 (6.19) 3J Rp3 89(3.5) 920082 920144 C C D D 4.12 (9.08) Rp4 114 (4.5) 920084 920146 C C D D 4.84 (10.7) 200 8 3J 219.1 (8.63) Rp2 64(2.5) 915539 915560 C - D D 4.94 (10.9) Rp2.1/2 70 (2.75) 920086 920147 C C D D 5.24 (11.6) Rp3 89(3.5) 920088 920149 C C D D 5.45 (12) Rp4 114 (4.5) 920090 920151 C C D 0 6.84 (15.1) 00 = Outside Diameter Working pressure: A = max. 12.1 bar (175 psi)! B = max. 15.5 bar (225 psi)! C = max. 16 bar (232 psi)! D = max. 20.7 bar (300 psi)! E = max. 25 bar (363 psi) / F = max. 34.5 bar (500 psi) / - = no approvals Technical data Ambient temperature ......-34 °C bis 110 °C (-30 °F bis 230 °F) Tightening torque: -DN5O ............................................... 40-60Nm(30-451b-ft) -0N65-DN100 .......................... 110-135Nm(80-1001b-ft) - 0N125, DN150 ....................... 135 - 175 Nm (100-130 lb-ft) -DN200 .................................... 175-245Nm(130-1801b-ft) Material I surface Mechanical tee ................................................ductile cast iron - Red paint ...............................liquid painting similar RAL 3000 - Galvanized ...................................................hot dip galvanized Gasket................................................................................EPDM Bolts and nuts .........................carbon steal, zinc electroplated Application Water based fire-fighting systems Note EPDM gaskets must never be brought into contact with lubri- cants or oils containing mineral oils, as well as other materials containing mineral oils (e.g. fuels or cleaning agents). Maintenance Visual check © Viking S.A. I Z.l. Flaneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 2/3 NJ I Ki W5 Product Data Sheet I Water - Grooved Products Pipe couplings and fittings Mech Tees - Threaded Dimensional drawing Dimensions in mm (inch) DN Inch Model Threaded outlet A B C D Bolts! Nuts SW 50/60.3 2 3J Rp1/2 - Rp1 116 (4.57) 68 (2.68) 60 (2.36) 39 (1.54) M10x55 16 Rp1.1/4 - Rp1.1/2 116 (4.57) 76(2.99) 65(2.56) 39(1.54) M10x55 16 65/76.1 3 OD 3J Rp1/2 - Rp1 137 (5.39) 71(2.80) 61.5 (2.42) 49.5(l.95) M12x70 16 Rp1.1/4 - Rp1.1/2 137 (5.39) 84.5 (3.33) 75(3.05) 49.5(l.95) M12x70 22 80/88.9 3 3J I Rp1/2 - Rp1 152 (5.98) 72.5 (2.85) 71.5 (2.81) 56.5 (2.22) M12x75 22 Rp1.1/4 - Rp1.1/2 152 (5.98) 85.5 (3.37) 80(3.15) 56.5 (2.22) M12x75 22 Rp2 152 (5.98) 98 (3.86) 80 (3.15) 56.5 (2.22) M12x75 22 100/114.3 4 3J Rp1/2 - Rp3/4 188 (7.40) 78.5 (3.09) 90(3.54) 70 (2.76) M12x75 22 Rp1 188 (7.40) 78.5 (3.09) 93 (3.66) 70 (2.76) M12x75 22 Rp1.114 188 (7.40) 89(3.50) 95(3.74) 70(2.76) M12x75 22 Rp1.1/2 188 (7.40) 89(3.50) 97(3.82) 70(2.76) M12x75 22 Rp2 188 (7.40) 104.5 (4.11) 100 (4.02) 70 (2.76) M12x75 22 Rp2.1/2 188 (7.40) 104.5 (4.11) 102 (4.02) 70 (2.76) M12x75 22 3JS Rp2.1/2 178 (7.01) 103.5 (4.07) 98(3.86) 67.5 (2.66) M12x76 22 3J Rp3 188 (7.40) 128 (5.04) 102 (4.02) 70 (2.76) M12x75 22 125/139.7 5-1/2 OD 3J Rp1.1/4 - Rp1.1/2 221.5 (8.72) 95(3.7) 112 (4.41) 84(3.31) M16x85 24 Rp2 - Rp2.1/2 221.5 (8.72) 112.5 (4.43) 115 (4.53) 84 (3.31) M16x85 24 3JS Rp2.1/2 210 (8.27) 110 (4.33) 125 (4.92) 94.5 (3.72) M16x85 24 150/165.1 6-1/2 OD 3J Rp1.1/4 - Rp1.1/2 244 (9.60) 93(3.66) 118 (4.65) 97.5 (3.84) M16x105 24 Rp2 - Rp2.1/2 244 (9.60) 112.5 (4.43) 128.5 (5.06) 97.5 (3.84) M16x105 24 3JS Rp2.1/2 235 (9.25) 110 (4.33) 125 (4.92) 1 94.5 (3.72) M16x108 24 3J Rp3 244 (9.60) 132 (5.20) 128.5 (5.06) 97.5 (3.84) M16x105 24 Rp4 244 (9.60) 154 (6.18) 135 (5.32) 97.5 (3.84) M16x105 24 Rp4 240 (9.45) 155 (6.10) 130 (5.12) 94.5 (3.72) M16x108 24 150/168.3 6 3J Rp1 .1/4 - Rp1 .1/2 247 (9.72) 95 (3.74) 122 (4.8) 98.5 (3.88) M16x105 24 Rp2 - Rp2.1/2 247 (9.72) 112.5 (4.43) 132 (5.2) 98.5 (3.88) M16x105 24 3JS Rp2.1/2 240 (9.45) 110 (4.33) 127 (5.00) 96.5 (3.80) M16x108 24 3J Rp3 247 (9.72) 98.5 (3.88) M16x105 24 Rp4 247 (9.72) 160 (6.30) 98.5(3.88) M16x105 24 200/219.1 8 3J Rp2 320(12.6) 117(4.61) 125(4.92) M20x115 30 Rp2.1/2 320(12.6) 132 (5.2)tl 118(4.65) g(6300)) 125(4.92) M20x115 30 Rp3 320(12.6) 136.5 (5.37 125(4.92) M20x115 30 Rp4 320(12.6) 164(6.46) 125 (4.92) M20x115 30 [j © Viking S.A. I Z.I. Haneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 3/3 1k 201" Product Data Sheet I Water - Grooved Products Pipe couplings and fittings Mech Tees - Grooved Approvals Vd~S C APPROVED LISTED RU Nominal size Model Pipe OD mm (Inch) Grooved outlet Hole Dia +3.20 (+0.126) mm (inch) Part no. Approvals Weight DN Inch Red paint similar Galvanized RAL 3000 VdS LPCB FM UL kg (Ibs) 50 2 3G 60.3 (2.37) DN32/42.4 45(1.75) 915561 915580 C - D D 0.73(1.6) DN40/48.3 45 (1.75) 915562 915581 C - D D 0.77 (1.7) 65 3 3G 76.1 (3.0) DN32/42.4 51(2.00) 915563 915582 C - D D 0.73 (1 .6) DN40/48.3 51(2.00) 915564 915583 C - D I D 0.77 (1 .7) 80 3 3G 88.9 (3.5) DN32/42.4 51(2.00) 915565 915584 C - D D 1.23(2.72) 0N40 /48.3 51(2.00) 915566 915585 C - D D 1.26 (2.77) DNSO /60.3 64 (2.50) 915567 915586 C - D D 1.39 (3.07) 100 4 3G 114.3 (4.5) 0N32/42.4 51(2.00) 915568 915587 C - D D (2.00) 0N40/48.3 51(2.00) 915569 915588 C - 0 D (2.00) DN50/60.3 64(2.50) 915570 915589 C - D D (2.50) DN65 / 73 70 (2.75) 920092 920152 - - D D (2.75) DN65/76.1 70(2.75) 915571 915590 C C - - (2.75) 3GS DN65 / 76.1 70 (2.75) 920093 920154 - - D 0 1.53 (3.37) 3G DN80 / 88.9 89 (3.50) 915572 915591 C C D 0 (3.50) 125 5-1/2 3G 139.7 (5.5) DN50/60.3 64 (2.50) 915573 915592 C - D D (2.50) DN65 / 76.1 70(2.75) 915574 915593 C C - - (2.75) 3GS DN65/76.1 70 (2.75) 920094 920155 - - D D 2.14(4.72) 150 6-1/2 3G 165.1 (6.5) DN50 / 60.3 64 (2.50) 920096 920157 - - - 0 3.04 (6.70) DN65 / 76.1 70(2.75) 920098 920158 - - C - 3.11 (6.86) 3GS DN65 / 76.1 70 (2.75) 920099 920160 - - D D 2.49 (5.48) 3G DN80 / 88.9 89 (3.50) 920100 920162 - - C D 3.22 (7.10) DN100 / 114.3 114 (4.50) 920101 920164 - - C D 3.78 (8.33) 150 6 3GS 168.3 (6.63) DN40 / 48.3 51(2.00) 920103 920165 - - D D 2.37 (5.23) 3G DN40/48.3 51(2.00) 915575 915594 C - 0 D 2.93(6.45) DN50/60.3 64 (2.50) 915576 915595 C - D D 3.15(6.95) DN65 / 73 70 (2.75) 920107 920169 - - D D 3.33 (7.34) DN65 / 76.1 70 (2.75) 915577 915596 C C - - 3.28 (7.24) 3GS DN65 / 76.1 70 (2.75) 920108 920170 - - D D 2.63 (5.81) 3G DN80/88.9 89 (3.50) 915578 915597 C C a D 3.44(7.57) DN100/ 114.3 114 (4.50) 915579 915598 C C D D 4.41 (9.72) 200 8 3G 219.1 (8.63) DN50 / 60.3 64 (2.50) 920110 920172 C - D 0 4.84 (10.7) DN65 / 76.1 70 (2.75) 920111 920173 C C D D 4.78 (10.5) DN80/88.9 89 (3.50) 920113 920174 C C D D 5.32 (11.7) DN100 / 114.3 114 (4.50) 920115 920175 C C D D 5.51 (12.2) OD = Outside Diameter . Working pressure: A = max. 12.1 bar (175 psi)! B = max. 15.5 bar (225 psi)! C = max. 16 bar (232 psi)/ D = max. 20.7 bar (300 psi)! E = max. 25 bar (363 psi) IF = max. 34.5 bar (500 psi)! - = no approvals © Viking S.A. I Z.l. Haneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 1/2 LII Product Data Sheet I Water - Grooved Products Pipe couplings and fittings Mech Tees - Grooved Technical data Type.....................................................................................3G Mechanical tee ............................................................grooved Ambient temperature.......... -34°C to 110°C (-30°F to 230 °F) Tightening torque: -DN5O .............................................. 40-60Nm(30-451b-ft) -DN65-DN100 .......................... .110-135Nm(80-1001b-ft) - DN125, DNI50 ....................... 135 - 175 Nm (100- 130 lb-ft) -DN200 .................................... 175-245Nm(130-l8olb-ft) Material I surface Mechanical tee ................................................ductile cast iron - Red paint ...............................liquid painting similar RAL 3000 - Galvanized ...................................................hot dip galvanized Gasket...............................................................................EPDM Bolts and nuts .........................carbon steal, zinc electroplated Application Water based fire-suppression systems Note EPDM gaskets must never be brought into contact with lubri- cants or oils containing mineral oils, as well as other materials containing mineral oils (e.g. fuels or cleaning agents). Maintenance Visual check Dimensional drawing Dimensions in mm (inch) DN Inch Model Grooved outlet A B C D Bolts - Nuts SW 50/60.3 2 3G DN32 - DN40 116 (4.57) 76.0 (2.99) 69.5 (2.74) 39.0 (1.54) M10x55 16 65/76.1 30D 3G DN32 - DN40 137 (5.39) 84.5 (3.33) 78.0 (3.07) 49.5(l.95) M12x70 16 80/88.9 3 3G DN32 - DN40 152 (5.98) 85.5 (3.37) 84.5 (3.33) 56.5 (2.22) M12x70 22 DN50 152 (5.98) 98.0 (3.86) 84.5 (3.33) 56.5 (2.22) M12x70 22 100/114.3 4 3G DN32 - DN40 188 (7.40) 89.0 (3.50) 102.0 (4.02) 70.0 (2.76) M12x70 22 DN50 - DN65 188 (7.40) 104.5 (4.11) 102.0 (4.02) 70.0 (2.76) M12x70 22 3GS DN65 178 (7.01) 103.5 (4.07) 98.0 (3.86) 67.5 (2.66) M12x76 22 3G DN80 188 (7.40) 128.0 (5.03) 102.0 (4.02) 70.0 (2.76) M12x70 22 125 / 139.7 5-1/2 OD 3G DN50 - DN65 221.5(8.72) 112.5 (4.43) 118.0 (4.65) 84.0 (3.31) M16x85 24 3GS DN65 210 (8.27) 110.0 (4.33) 113.0 (4.45) 82.0 (3.23) M16x85 24 150 / 165.1 6-1/2 OD 3G DN50 244 (9.60) 112.5 (4.43) 127.0 (5.00) 97.5 (3.84) M16x105 24 DN65 244 (9.60) 112.5 (4.43) 130.0 (5.12) 97.5 (3.84) M16x105 24 3GS 235 (9.25) 110.0 (4.33) 124.5 (4.90) 94.5 (3.72) M16x108 24 3G DN80 244 (9.60) 132.0 (5.20) 130.0 (5.12) 97.5 (3.84) M16x105 24 DN100 244 (9.60) 1154.0 (6.06) 128.5 (5.06) 97.5 (3.84) M16x105 24 150/168.3 6 3GS DN40 240 (9.45) 92.5 (3.64) 126.0 (4.96) 96.5 (3.80) M16x108 24 3G 247 (9.72) 95.0 (3.74) 128.0 (5.04) 98.5 (3.88) M16x105 24 DN50 247 (9.72) 114.0 (4.49) 134.0 (5.28) 98.5 (3.88) M16x105 24 DN65 247 (9.72) 112.5 (4.42) 134.0 (5.28) 98.5 (3.88) M16x105 24 3GS 240 (9.45) 110.0 (4.33)1 126.0 (4.96) 96.5 (3.80) M16x108 24 3G DNSO 247 (9.72) 132.0 (5.20) 141.0 (5.55) 98.5 (3.88) M16x105 24 DN100 247 (9.72) 160.0 (6.30) 138.0 (5.43) 98.5 (3.88) M16x105 24 200/219.1 8 3G DN50 - DN65 322 (12.7) 118.0 (4.65) 158.0 (6.22) 125.0 (4.92) M20x115 30 DN80 322 (12.7) 136.5 (5.37) 161.0 (6.34) 125.0 (4.92) M20x115 30 DN100 322 (12.7) 164.0 (6.46) 161.0 (6.34) 125.0 (4.92)1 M20x115 30 [_1 © Viking S.A. I Z.l. Haneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 2/2 Product Data Sheet I Water - Grooved Products Pipe couplings and fittings Sprinkler Tees Approvals 1 LISTED C Nominal size Pipe OD mm (Inch) Threaded outlet Part no. Hole Dia +1.60(+0 .063) Approvals Weight approx. DN lnch Red paint Galvanized mm (Inch) VdS FM UL kg (Ibs) 32 1-1/4 42.4(l.66) Rp1/2 919264 919252 30(1.18) C D D 0.41 (0.90) Rp3/4 919265 919253 30(1.18) C D D 0.44 (0.97) Rp1 919266 919254 30 (1.18) C D D 0.49 (1.08) 40 1-1/2 48.3(l.90) Rp1/2 919267 919255 30(1.18) C D D 0.40 (0.88) Rp3/4 919268 919256 30(1.18) C D D 0.43 (0.95) Rp1 919269 919257 30 (1.18) C 0 D 0.48 (1.06) 50 2 60.3 (2.37) Rp1/2 919270 919258 30(1.18) C 0 D 0.41 (0.90) Rp3/4 919271 919259 30(1.18) C 0 0 0.44 (0.97) Rp1 919272 919260 30(l.18) C D 0 0.49 (1.08) 65 3 OD 76.1 (3.00) Rp1/2 919273 919261 30(1.18) C 0 0 0.44 (0.97) Rp3/4 919274 919262 30(1.18) C 0 0 0.47 (1.04) Rp1 919275 919263 30 (1.18) C 0 D 0.51 (1.12) OD = Outside Diameter Working pressure: A = max. 12.1 bar (175 psi)! B = max. 15.5 bar (225 psi)! C = max. 16 bar (232 psi)! D = max. 20.7 bar (300 psi)! E = max. 25 bar (363 psi)! F = max. 34.5 bar (500 psi)! - = no approvals Technical data Type......................................................................................3L ! Thread .....................................................according to ISO 7/1 Ambient temperature ......... -34 C to 110 °C (-30 °F to 230 °F) Tightening torque................................40 - 60 Nm (30 - 45 lb-ft) Material I surface Sprinkler tee ....................................................ductile cast iron - Red paint ...............................liquid painting similar RAL 3000 > - Galvanized ...................................................hot dip galvanized Gasket...............................................................................EPDM Bolts and nuts ..........................carbon 10 steal, zinc electroplated Application Water based fire-suppression systems Note EPDM gaskets must never be brought into contact with lubri- cants or oils containing mineral oils, as well as other materials containing mineral oils (e.g. fuels or cleaning agents). Maintenance Visual check © Viking S.A. I Z.I. Haneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 3'4 Fl— - Product,Data Sheet I Water - Grooved Products Pipe couplings and fittings Sprinkler Tees Dimensional drawing Dimensions in mm (inch) DN Inch Threaded A B C Bolts SW outlet (mm /unch) (mm / inch) (mm /unch) Nuts 32/ 1-1/4 Rpli2 - Rp3/4 54.4 (2.14) 88.9 (3.50) 57.2 (2.25) M10x73 15 42.4 Rp1 57.7 (2.27) 88.9 (3.50) 57.2 (2.25) M10x73 - 15 Rp1/2 43(1.69) 88.9 (3.50) 57.2 (2.25) M10x73 15 40/ 48.3 1-1/2 Rp3/4 51(2.00) 88.9 (3.50) 57.2 (2.25) M10x73 15 Rp1 60.8 (2.39) 88.9 (3.50) 57.2 (2.25) M10x73 15 50/ 2 Rp1/2 - Rp3/4 63.3 (2.49) 95.3 (3.75) 57.2 (2.25) M10x90 15 60.3 Rp1 66.6 (2.62) 95.3 (3.75) 57.2 (2.25) M10x90 15 65/ 30D Rp1/2 - Rp3/4 69.9 (2.75) 108 (4.25) 57.2 (2.25) M10x105 15 76.1 Rp1 73.2 (2.88) 108 (4.25) 57.2 (2.25) M10x105 15 [ © Viking S.A. I Z.l. Haneboesch I L-4562 Differdange/Niederkorn I www.viking-emea.com I Page 4'4 IL 100" Fig. 200-/2 to 200-2 Fig. 200-21/2 to 200-8 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line 1133170NFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFC) Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size ** Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or200Mi0-11/2 - Fig. 200C 0 Fig. 200 200-I2 I L TI1t: 3/811-16 I M8 or M10 31/8 (79.4) ' 2I8 (66.7) I 400 I (1.78) 11 I (5.0) 200-I4 3/4 (20) /8"-16 MS or M10 31/8° (79.4) 21/2 (63.5) 400 (1.78) 11 (5.0) 200-1 1" (25) /8°-16 M8 or M10 3/8° (85.7) 25/8 (66.7) 400 (1.78) 12 (5.5) 200_11/4 11/4 (32) /8'-16 M8 or M10 33/4 (94.0) 2/8" (73.0) 400 (1.78) 13 (5.9) 200_11/2 /8"-16 M8 or M10 3/8° (98.4) 2I8" (73.0) 400 (1.78) 14 (6.4) 200-2 2 (0) /8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 400 (1.78) 15 (6.9) 200_21/2 21/2" (65) /8'-16 M10 5/8' (142.9) 41/8 (104.7) 600 (2.67) 27 (12.3) 200-3 3° (75) /8'-16 M10 5I8° (149.1) 4" (101.6) 600 (2.67) 29 (13.3) 200-3I2 31/2° (90) /811-16 M10 7/8" (187.3) 51/4" (133.3) 600 (2.67) 34 (15.6) 200-4 4° (100) /8'-16 M10 7 /8" (187.3) 5" (127.0) 1000 (4.45) 35 (16.0) 200-5 5° (125) 1/2"..13 M12 91/811 (231.8) 61/4 (158.7) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2°13 M12 101/8' (257.2) 6/4" (171.4) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2°..13 M12 131/8 (333.4) 8/4" (222.2) 1250 (5.56) 136 (62.3) B-Line by ET4%1 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 61 Pipe Hangers & Supports All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Pipe Hangers & Supports 62 B- Line by .j Pipe Hangers Fig. 200H - Heavy Duty Band Hanger (For Trapeze) ®TOLCC Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used US extensively to support trapeze installations and the increased loads LISTEO from both above and below the trapeze assembly. Features: Furnished with /8-16 or 1/2°..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Part number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 1Part INo. 200H-2-3/s Pipe I 2° Size (50) Rod Size /8°-16 in. 4I16" A (115.9) in. 3/32° B (81.7) CMax. Rec. Load 1200 (5.34) Approx.LIII 48 (21.8) 200H-2-1/2 2° (50) 1/2"13 423/32° (119.8) 3/8° (85.7) 1200 - (5.34) 45 (20.4) 200H-21/2-3/8 21/2' (65) /811-16 5I16° (134.9) 323/32" (94.4) 1200 (5.34) 59 (26.7) 200H-2112-112 21/2" - (65) - 1/2°_13 - - 515/" (138.9) 3/8" (98.3) 1200 (5.34) 56 -. (25.4) -- 200H-3-3/8 311 (75) /811-16 53/4° (146.0) 327/32" (97.6) 1200 (5.34) 63 (28.6) 200H-3-1/2 311 (75) 1/2°_13 . . 57/8" (148.1) 331/32" (100.8) 1200 (5.34) 60 (27.2) 200H-4-3/8 4° (100) /8°-16 -. 6/8° (174.6) 4/16° (.112.7) 1200 (5.34) 76 (34.5) 200H-4-1/2 4° (100) - 1/2"..13 - 71/32° 1 (178.6) 1 419/32' (1116.7) - 1200 - - (534) 1 73 * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b). All sizes are UL Listed to support up to 8° pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory.