HomeMy WebLinkAbout5098 SHORE DR; ; FPR2019-0147; PermitIUANZ 014 ('7city of Carlsbad Print Date: 10/24/2024 Job Address: 5098 SHORE DR, CARLSBAD, CA 92008-4344 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2100320100 Track #: Valuation: $686,646.48 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Plan Check 4*: Permit No: FPR2019-0147 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 07/09/2019 Issued: 03/23/2020 DEV2017-0001 Finaled Close Out: 12/01/2020 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: PRITCHARD RESIDENCE Description: PRITCHARD RESIDENCE - REVISED PLANS FOR NEW 13D SYSTEM Applicant: FPContractor: ALLWAYS FIRE PROTECTION INC ALLWAYS FIRE PROTECTION INC CHRIS FOX 1451 KENT AVE 1451 KENT AVE ESCONDIDO, CA 92027-1419 ESCONDIDO, CA 92027-1419 (760) 535-9234 (760) 535-9234 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 FIRE Plan Review Per Hour - Office Hours - $408.00 Total Fees: $779.00 Total Payments To Date: $779.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 I Inspections: 442-339-2660 1 www.carlsbadca.gov IHydrau1ic Summary I Job Number: 74- 1HD CALC Renort DescriDtion: Residential (2( Job Job Ncaebe, 74 0eO Eoea,ee, ALLWAYS FIRE PRO. Job 500rDr PRITCHARD RESIDENCE SDrteCantdtbN1Lcense Plurither 897230 oasessi 5098 SHORE DR, CARLSBAD CA 92008 RIO CITY OF CARLSBAD FIRE DEPARTMENT Address 2 Job Si./Building bdcbess3 Dm0009 Name PRITCHARD RES System u. RemoteArea(s) MOSt Demondknq Srnirkteo Burn 4.9 K-Factor 20.00 at 16.660 Ossupancy Residential Job S.M. 1HD CALC Hoqe Pdlcsoanebt bounce 0.00 Density 0.05g pm/ft° Area etydrpleation 500ft° (Actual 71ft0) Additional Hose SuppILes Node Hose At Node 9 Flow(oom) 5.00 Number 0tbprinklers Calculated Numbor 01 1 0 5000105 Colculaled Couenogn Per Sprinkler 400ft° AutoPoaliResullO.Pt005ure FnnHonatedroels(iodjocerrtloteaslyeinolekce Total Hood St- 5.00 Syqtenr rlOeu Dentend 25.00 Coral Vuloter Requited (Including Hose djloouance) 25.00 Maairmcm Pressure bnbalanse On W- 0.000 11 `4Z` Ground 8.42 between nodes 7 and 6 Maximum Velocity Under Gre und 10.32 between nodes 8 and 7 tkkrrne cepaedy 00 VAt Pipes 30.32ga1 OSturne cepacty 00 Dry Pipes Supplies II Node Name Hose Flow Static Residual (gpm) (psi) (psi) Flow Available (gpm) (psi) Total Demand Required (gpm) (psi) Safety Margin 8 I Water Supply I 77.000 20.000 500.00 76.777 25.00 49.942 26.835 Contractor r Contraneor Hooter Connote N.— N.— .1 C.- 09000 Eaterrolon I FM BRItoNs 2 it-melt BddnesO3 Web-bite Inc. AutoSPRINK2019v15.1.15.0 1/17/2020 10:03:40AM Page 1 IHydrauIio Graph Job Number: 74- 1RD CALC Pnnrf fl'rir,*i,,n I') Water Supply at Node 8 100— go--- 80-1 Static Pressure 77.000 70- -\ - 60 CL 19.942 ' :1 T 30 - stem demand curve- 20- 500.00 20.. 10- 0—..l.l.lJ.l.l.I.1IIIIIiiliIi __________ IIIIiII iIrIIIII Illililil I I 00 200 300 400 500 800 700 800 900 1000 Water flow, gpm HIG,op, Water Supply at Node 8 SIafic:Prssu,e 77.000 Residual: R-- 20.000 @ 500.00 A aRe Pressu re at reree oF To at 76.777 @ 25.00 SrRem Oemard 49.942 @ 25.00 State m OCT end (FrAud Ir9 H tan Aeoaarce or SQU tel 49.942 @ 25.00 f, 0 M.E.P.CAD, Inc. jj AutoSPRINK 2019 05.1.15.0 1/17/2020 10:03:42AM Page 2 ~jjjjHydraullc Graph Job Number: 74- 1 H CALC BOR 100- 90- 80— Static Pressure 77.000 70 60 CL CL 40— .00 33.505 30— 20 stem demand curve ______ 00.00 2o.000________ 10--- UWWWiU.LIIIIIIHH IIIHtIH 11111111 0 111111111 IIII liii 1111111 I I I 11111 00 200 400 500 600 700 800 1000 Water flow, gpm flyd,auhcsi!aph BOR N/A Residual: Pressure N/A dusdablePressure ulmresrrest N/A Sillem userard 33.505 @ 20.00 srslalrroerraid (Iefldmg -A- 3 3.505 @ N/A , © ME.P.CAD, Inc. 11 AutoSPRINK 2019 05.1.15.0 1/17/2020 10:03:42AM Page 3 1111Hydraulic Graph :c Job Number: 74- 1 H CALC Rennrt flosririntion PpsidntiI (2 TOR 100- 90 80— tatic Pressure 77.000 70- -\ 60- CL 50 CL - 40- 30- .00 28.5b 20 - ______ ________ 000 20.000 .tern demand curve 10- ULLLLLWJ.I.UHhIHII?'IIIIIIII 11111111 IIII1III 111111111 IIllIIII liii I It 0— Q100 200 300 400 500 600 700 800 -: 1000 Water flow, gpm Hydraulic Staph TO Static: Pressure N/A Residual: Pressure N/A AsartablePieSsure atrltneotresa N/A Sysueet eseusra 28.515 @20.00 System aematta SrSSy cO,aSllcasnce at haulce) 28.515 @ N/A , 0 M.E.P.CAD, Inc. Ll AutoSPRINK 2019 05.1.150 1/17/2020 10:03:42AM Page 4 ~jjy jSummary Of Outflowrng Devices I Job Number 74 1HD CALC , © M.E.P.CAD, Inc. ImAutoSPRINK 2019 05.1.150 111712020 10:03:44AM Page 5 INde Analysis . I Job Number: 74- 1 H CALC Prvrf flnfinn PidntiI (\ Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 8 4-6 S 49.942 25.00 9 3-0 Hose(-0.000) 33.284 5.00 251 19-1% Spr(-16.660) 16.660 20.00 3 19-6 1(5-0) 19.399 4 10-6 E(7-0), TOR 28.515 5 1-6 E(7'-O), BOR 33.505 6 1-6 T(5-0), Tr(1-0) 33.948 7 -1-6 WMV(-6.000) 47.417 98 19-6 C(5'-O) 17.509 15, © M.E.P.CAD, Inc. J AutoSPRINK 2019 05.1.15.0 1/17/2020 10:03:45AM Page 6 ~jjj _____Analysis I Job Number: 74- 1HD CALC Report Description: Residential (2) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length _Total Length Summary Route 11 ..... DR 1.1010 20.00 6.74 150 0.068041 2-10% Pt 1.012 251 98 19-1% 19-6 20.00 4.9 16.660 17.509 Sprinkle E(7'-O), C(5'-O) 12-0 14-10% Pe Pv -0.163 BL 1.1010 11.02 3.71 150 0.022571 60-9 Pt 1.890 98 3 19-6 19-6 17.509 19.399 6Tr(1'-0), E(7'-0), Z, 2T(5'-O) 23-0 83'-9 Pe PV BL 1.1010 20.00 6.74 150 0.068041 34-7% Pt 5.214 3 4 19-6 106 8.98 19.399 28.515 Flow (q) from Route 3 2Tr(1-0), 5E(7'-0), 1(5-0), TOR 42-0 76'7% Pe Pv 3.902 BL 1.1010 20.00 6.74 150 0.068041 9-0 Pt 1.089 4 5 10-6 1-6 28.515 33.505 CV, E(7'-0), BOR 7-0 16-0 Pe Pv 3.902 BL 1.1010 2000 6.74 150 0.068041 1-6 Pt 0.442 5 6 1-6 1-6 33.505 33.948 T(5-0) 51-0 6-6 Pe Pv BL 1.1010 25.00 842 150 0.102815 53-0 Pt 12.168 6 7 1-6 -1-6 5.00 33.948 47.417 Flow (q) from Route 2 E(7'-0), WMV(-6.000) 7-0 60-0 Pc Pv 1.301 UG 0.9950 25.00 10.32 150 0.168329 15-0 Pf 2.525 7 8 -1-6 1'6 47.417 49.942 Water Supply 15-0 Pe Pv 0.00 Hose Allowance At Source 8 25.00 =...... Route 2 ..... BL 1.1010 5.00 1.68 150 0.005236 1-6 Pt 0.013 9 6 3-0 1-6 5.00 33.284 33.948 Hose(-0.000) Tr(1'-O) 1,-U 76 Pe PV 0.650 Route ..... DL 1.1010 8.98 303 150 0.015483 77-1 1.890 98 3 19-6 19'-6 11.02 17.509 19.399 Flow (q) from Route 1 14Tr(1'-0), 3E(7'-0), 2T(5'-O) 45-0 122'1 ~Pf Pc Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule 40 Steel Pipe Inside Diameter .1. 487 ) = Factor C Value Multiplier . value otc 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 ,, 0 M.E.P.CAD, Inc. AutoSPRINK 2019 v15.1. 15.0 1/17/2020 10:03:47AM Page 7 Job Number: 74- 1 H CALC rt Descriotion: Residential (2) Eq. Length Summa Total Length Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 900 Elbow EE 450 Elbow Eel 11W Elbow Ee2 22%° Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PD Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer I Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap lHydraulic Analysis Pipe Type Diameter Flow Velocity HWC Friction Downstream Elevation Discharge K-Factor Pt Pn Fittings Upstream Pipe Type Legend Units Legend e AO Arm-Over Diameter Inch BL Branch Line Elevation Foot CM Cross Main Flce gpm DN Drain DR Drop Discharge gpm DY Dynamic Velocity fps FM Feed Main Pressure psi FR Feed Riser Length Foot MS Miscellaneous Friction Loss psi/Foot OR Outrigger HWC Hazen-Williams Constant RN Riser Nipple SP Sprig Pt Total pressure at a point in a pipe ST Stand Pipe Pn Normal pressure at a point in a pipe UG Underground Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe , © M.E.P.CAD, Inc. lJAutoSPRINK 2019 v15.1 .15.0 1/17/2020 10:03:47AM Page 8 ICheck Point Gauge Data Job Number: 74- 1HD CALC IRiser Tag I Job Number: 74- 1HD CALC Job PRITCHARD RESIDENCE 5098 SHORE DR, CARLSBAD CA 92008 Design Basis Occupancy: Residential Total Sprinklers: 60 Number Of Sprinklers Calculated: I Number Of Nozzles Calculated: 0 K-Factor: 4.9 Orifice Size: 0.437 Design Density: 0.05gpm/ft2 Average Density: 0.28gpm/ft2 Area of Application: 500ft2 (Actual 71ft2) Demand At Base Of Riser (BOR) Total Demand Flow(gpm): 20.00 Pressure(psi): 33.505 Water Supply Information At Time Of Design Static Pressure(psi): 77.000 Residual Pressure(psi): 20.000 Supply Flow(gpm): 500.00 Total Demand Flow(gpm): 25.00 Total Demand Pressure(psi): 49.942 ,©M.E.P.CAD, Inc. M AutoSPRINK 2019 v15.1.15.0 1/17/2020 10:03:50AM Page 10 Hydraulic Summary Job Number: 74 - 2HD CALC Reoort Descriotion: Residential (1) Job Job Ni000rer 74 Design EnNl0000 ALLWAYS FIRE PRO. Job 150mw PRITCHARD RESIDENCE Stole CxrlreoattorolUoonse Disrober 897230 Address 1 5098 SHORE DR, CARLSBAD CA 92008 AHJ CITY OF CARLSBAD FIRE DEPARTMENT Address 2 Job Site/Building Address - Drawing Name PRITCHARD RES System RemoteArea(s) Most Demanding Sprinkler Data 4.9K-Factor 12.96 at 7.000 oouupency Residential Job SoilS 2HD CALC Hose Allowxnre At Soomox 0.00 Density 0.05g pm/ftc Aroe olAppicellon 500ft2 (Actual 161ft2) 4ddtt105r& 14050 Snpp000 Node Hose At Node 9 Flow(gpm) 5.00 Number or Sprinkiors Ceinuloted Number Oil Nonplus Cotnuiotod 2 0 Couorego PHi Sprinkler 256ft2 AutoPeek Resuitel 110000ro For Remote Areo(n) Adjaoert To Most Remote Area Right: 49.193 iota, lose Streams 5.00 System Flow Demand 31.00 Totei SIster Required tinoiudlng Hose Allewenox) 31.00 Maximum Pressure Unbalance In Loops 0.000 Maximum VeiooiryAbove Ground 10.45 between nodes 7 and 6 Maxi mnunn Veiootty Under Ground 12.79 between nodes 8 and 7 Volume sepeSily of IrIsh Pipes 30.32ga1 Volume eapsully of Dry Pipos Supplies Node Name Hose Flow Static Residual Flow (gpm) (psi) (psi) (gpm) Available (psi) @ Total Demand Required (gpm) (psi) Safety Margin (psi) 8 Water Supply I 77.000 I 20.000 500.00 76.668 31.00 49.366 27.302 Contractor - - Conlraoter Number Content Some Confect Ill - Neme of ContrxUtor, Phone Ertxnslon Address FAX Address 2 E-mail bddrssuy XIsb.SUo f,©M.E.P. CAD, Inc. AutoSPRlNK 2019 v15.1.15.0 1/17/2020 10:03:12AM Page 1 IHydraulic Graph I Job Number: 74 - 2HD CALC Rnort Dsrintion: Residential (1 Water Supply at Node 8 100-: 90 80------ Static Pressure 77.000 °—: 601 49.36,N .00 501: I 40 30 - stem demand curve- 00.00 20.000 201 OH - 01111LW11111.1111111111111111111 11111111 t?IIIIIII IItIIII IIIilIIl 11111 II 00 200 300 400 500 600 700 800 900 1000 Water flow, gpm stydraUUc Graph Water Supply at Node 8 Start: Pressure 77.000 flestdccal: P-- 20.000 @ 500.00 Avaeeble Pressure at limo 011051 76.668 @ 31.00 SystrmDerrrarst 49.366 @31.00 - System Oerrerd (IraIrtireHeseaII000rte at Source) 49.366 @31.00 (, © M.E.P.CAD, Inc. ] AutoSPRINK 2019 05.1.15.0 1/17/2020 10:03:14AM Page 2 1111Hydraulic Graph .. Job Number: 74- 2HD CALC Rssranrf flss'rinfinn RsidnfiI 111 BOR 100-: 90— 80—--- Static Pressure 77.000 70.\_ -\ 60 CL ' : r S fstem demand curve OH 0- IIJ.I.L1'i.I.U.I..LLI IIIIIItI 111111111 11111111 11111111 I II III III liii I I I I I I I 200 300 400 500 600 700 800 900 1000 00 Water flow, gpm Hyd,auflo Steps BOR Stalls: Pressure N/A Residual: Pressure N/A Available Pressure at lime at Test N/A Sestasr DemaM 28.405 @ 26.00 System (lasrrarlt p,idrdrg tress ulaaar5ca at Setete) 28.405 @ N/A I, © M.E.P.CAD, Inc. ] AutoSPRINK 2019 05.1.15.0 1/17/2020 10:03:14AM Page 3 11111Hydraulic Graph 1 Job Number: 74 - 2HD CALC Puanrt fl ,rirrfiysn Poraraideentiesi 11 TOR 100 90-: 80- -Static Pressure 77.000 70- 60 50— a) 0 40— 30 6.00 22.735 20- 0.00@20.000________ S stem demand curve OH 0_1LLLWJJ.UJ.LUhhhhhhhh1 llItlII IIlIIlII lIIllIt liii liii 11111111 00 200 300 400 500 600 700 800 900 1000 Water flow, gpm Etydreuffc Graph TOR Static: Pressure N/A Residual: Pressure N/A Avatabla Pressure at 11111001100* N/A System Demarer 22.735 @ 26.00 SeAter Demand (trdrdmng Hose Aeoe,arce at Source) 22.735 @ N/A I, © M.E.P.CADr Inc. IJ AutoSPRINK 2019 v15.1.15.0 1/17/2020 10:03:14AM Page 4 ISummary Of Outfiowing Devices I Job Number: 74- 2HD CALC Rnnrt flsrintinn RpsirintiI 11 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hose 9 5.00 5.00 0 28.460 I c Sprinkler 101 12.96 12.80 4.9 7.000 I Sprinkler 102 I 13.03 12.80 4.9 1 7.076 I ' Most Demanding Sprinkler Data (, 0 M.E.P.CAD, Inc. 9AutoSPRlNK 2019 05.1.15.0 1/17/2020 10:03:16AM Page 5 Node Analysis I Job Number: 74 - 211D CALC ReDort DescriDtion: Residential (11 Node Elevation(Foot) Fittings Pressure(psi) I Dscharge(gpm) 8 -1-6 S 49.366 31.00 9 3-0 Hose(-0.000) 28.460 5.00 101 19-1% Spr(-7.000) 7.000 12.96 102 19-1%] Spr(-7.076) 7.076 13.03 1 19-6 T(5-0) 7.340 2 19-6 T(5-O), Tr(1-O) 7.340 3 19-6 T(5-O) 10.362 4 10-6 E(7-0), TOR 22.735 5 1-6 E(7-O), BOR 28.405 6 1-6 T(5-0),Tr(1-0) 29.124 7 -1-6 WMV(-6.000) 45.607 , © M.E.P.CAD, Inc. MI AutoSPRiNK 2019 v15.1.15.0 1/17/2020 10:03:17AM Page 6 I -YdraU11c Analysis), Job Number: 74- 2HD CALC Reoort Descriotion: Residential (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Totai Length .Route l ..... DR 1.1010 12.96 4.37 150 0.030510 4'-5V2 Pt 0.502 101 1 19-1 V2 19-6 12.96 4.9 7,000 7.340 Sprinkler, E(T-0), T(5'-O) 12-0 16-5Y2 Pc Pv -0.163 BL 1.1010 0.49 0.16 150 0.000070 6-10 Pt 0.001 1 2 19-6 19'-6 7.340 7.340 Tr(1-0) 1-0 7'110 Pc Pv BL 1.1010 13.52 4.56 150 0.032974 67-8 Pt 3.022 2 3 19-6 19'6 13.03 7.340 10.362 Flow (q) from Route 2 7Tr(1'-O), E(7'-O), Z, 2T(5'-O) 24-0 91-8 Pc Pv BL 1.1010 26.00 8.76 150 0.110543 34-7Y2 Pr 8.471 3 4 19-6 10'-6 12.48 10.362 22.735 Flow (q) from Route 4 2Tr(1'-O), 5E(7'-O), T(5'-O), TOR 42-0 7571 Pc Pv 3.902 BL 1.1010 26.00 8.76 150 0.110543 9-0 Pr 1.769 4 5 10-6 1-6 22.735 28.405 CV, E(7-0), BOR 7-0 16-0 Pc Pv 3.902 BL 1.1010 26.00 8.76 150 0.110543 1-6 Pr 0.719 5 6 1-6 1-6 28.405 29.124 1(5-0) 5-0 6-6 Pc ~Pv BL 1.1010 31.00 10.45 150 0.153058 53-0 Pt 15.183 6 7 1-6 -1-6 5.00 29.124 45.607 Flow (q) from Route 3 E(7'-O), WMV(-6.000) 7-0 60-0 Pc ~Pv 1.301 UG 0.9950 31.00 12.79 150 0.250588 15-0 Pt 3.759 7 8 -1-6 .1'6 45.607 49.366 Water Supply 151 0 Pc Pv 0.00 Hose Allowance At Source 8 31.00 =. ..... Route 2 - DR 1.1010 13.03 4.39 150 0.030818 1-10 Pt 0.426 102 2 191h/2 19-6 13.03 4.9 7.076 7.340 Sprinkler, E(7'-O), 1(5-0) . 12-0 13-10 Pc Pv -0.163 Go .Route3 ..... BL 1.1010 5.00 1.68 150 0.005236 1-6 Pt 0.013 9 6 3-0 1-6 5.00 28.460 29.124 Hose(-0.000) rr(1'-O) 1-0 Pc 2-6 Pv 0.650 =. ..... Route 4 ..... BL 1.1010 12.48 4.21 150 0.028430 63-4 Pt 3.023 1 3 19-6 19'6 0.49 7.340 10.362 Flow (q) from Route 1 12Tr(1-0), 3E(7-0), 21(5-0) 43-0 Pc 106'4 Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual inside Diameter ( Schedule 40 Steel Pipe Inside Diameter k 4.87 ) = Factor Ic Value Multiplier Value OfC 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 , 0 M.E.P.CAD, Inc. AutoSPRINK 2019 v15.1.15.0 1117/2020 10:03:19AM Page 7 ~111111ydraulic Analysis" Job Number: 74- 2HD CALC Report Description Residential (1) Pipe Type Diameter Flow Velocity HWC Friction Loss IL en gth Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream ITotal Length Pipe Type Legend * Units Legend 4 ...Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backfiow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 900 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DeIV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 900 Elbow UG Underground P1 Pressure loss due to friction between points EE 450 Elbow Pe Pressure due to elevation difference between indicated Eel 11 %' Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe I Flow Device Id Flex Drop FDC Fire Department Connection IE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SEx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 900 Tr Tee Run U Union WrF Wrsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. J AutoSPRINK 2019 vl 5.1.15.0 1/17/2020 10:03:19AM Page 8 Djjj Check Point Gauge Data Job Number: 74- 2HD CALC Report Description: Residential (1) Gauge I Pressure(psl) K-Factor(K) Flow(gpm) Inlet StatIc Pressure(psl) Elevation(Foot) BOR 28.405 4.88 26.00 75.699 1-6 TOR 22.735 5.45 1 26.00 71.798 10-6 ,©M.E.P.CAD, Inc. Fifil AutoSPRlNK2019v15.1.15.0 1/17/2020 10:03:21AM Paae 9 IRiser Tag I Job Number: 74 - 2HD CALC I Job PRITCHARD RESIDENCE 5098 SHORE DR, CARLSBAD CA 92008 Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated Number Of Nozzles Calculated: K-Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand At Base Of Riser (BOR) Total Demand Flow(gpm): P ressu re( PSi): Residential 60 2 0 4.9 0.437 0. 05g pm/ft2 0.16gpm/ft2 500ft2 (Actual 161ft2) Water Supply Information At Time Of Design Static Pressure(psi): 77.000 Residual Pressure(psi): 20.000 Supply Flow(gpm): 500.00 Total Demand Flow(gpm): 31.00 Total Demand PreSSure(psi): 49.366 M.E,P,CAD, Inc, AutoSPRINK2O19v15115,O 111712020 10:0322AM Page I tqcu Worldwide I Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.91K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 flush ceiling position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFll Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable Approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (1Y2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. DECEMBER 2018 1 Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. The Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compli- ance with this document and the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) 1Y2234 TFP400 TFP400 Page 2 of 6 7/16 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA.________ 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 4 -Bulb 5 - Compression 2 2 Screw -1/4 3 - Sealing Assembly 1 6 - Deflector* (57,2 mm) L _____ 1-5/8 * Temperature (41,3 mm) I w STYLE 20 RECESSED rating is 6* .., FLATS ESCUTCHEON indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) Technical Data Approvals UL Listed (for use with wet pipe and dry pipe systems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 Note: Sprinklers with a polyester finish are UL Listed as corrosion-resistant sprinklers. See the Design Criteria section for details on these approvals. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi/2 (70,6 LPM/bar½) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White Polyester Coated, Signal White Polyester Coated, or Chrome Plated Physical Characteristics Frame .............................Brass Button ...........................Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb (3 mm) ........................ Glass Compression Screw .................Bronze Deflector ..........................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet 1FP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the design area comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 in. to 4 in. TFP400 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coverae Ordinary Temperature Rating Intermediate Temperature Rating Area ( 155°F (68°C) 175°F (79°C) Minimum ft x ft Deflector to Ceiling Installation Type Spacing ft Flow Pressure Flow Pressure (m x m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Smooth Ceilings 1-1/4 in. to 4 in. 14 x 14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or13R 1-1/4 in. to non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 X 18 17 12.0 17 12.0 (5,5 X 5,5) (64,3) (0,83) (64,3) (0,83) in. below bottom of beam. 11-3/4 20 X 20 20 16.7 20 16.7 (6,1 x6,1) (75,7) (1,15) (75,7) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the net highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (Ppm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/f52 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure (2)(3) Coverae Ordinary Temperature Rating Intermediate Temperature Rating Area 155°F (68°C) 175°F (79°C) Minimum ft x ft (m x m) Deflector to Ceiling Installation Type Spacing ft Flow Pressure Flow Pressure gpm (I/mm) psi (bar) gpm (I/mm) psi (bar) (m) 12x12 13 7.0 13 7.0 (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Smooth Ceilings 1-1/4 in. to 4 in. 14 x 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Recessed using Style 20 16 x 16 15 9.4 15 9.4 Ceilings Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D or13R 1-1/4 in. to non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 X 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-3/4 in. below bottom of beam. 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ftl over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA laD, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 4 of 6 Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calcu- lated (for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area). Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. _______ 2-7/8' DIA. (73,0 mm) - 7/16±1/8 I 1/2' (12,7 mm) (11,1±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER MOUNTING FITTING PLATE / MOUNTING SURFACE 1/8" (3,2 mm) CLOSURE 1Y2234 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER WRENCH RECESS (END A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4) With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP400 Page 5 of 6 Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFll 4.91K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass ..... ............ 51-201-1-155 Pure White (RAL 9010) Polyester1.2 ..................51-201-3-155 Signal White (RAL 9003) Polyester' ....................51-201-4-155 Chrome Plated ................51-201-9-155 175°F (79°C) Natural Brass.................51-201-1-175 Pure White (RAL 9010) Polyester1, 2 51-201-3-175 Signal White (RAL 9003) Polyester1 ........... ......... 51-201-4-175 Chrome Plated ............... .51-201-9-175 UL Listed as corrosion-resistant. Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 tqco® Worldwide I Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are dec- orative, fast response, fusible solder sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Con- cealed Pendent Spnnklers provides 1/2 in. (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprin- kler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: Wet and dry pipe residential sprin- kler systems for one and two fam- ily dwellings and mobile homes per NFPA 13D Wet and dry pipe residential sprin- kler systems for residential occupan- cies up to and including four stories in height per NFPA 13R o Wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFll Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in fire situation or cause it to-operate-prematurely. Page 1 of 6 in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (1Y3596) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offer a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. MAY 2018 NOTICE The Series LFII Residential Concealed Pendent Sprinklers (fl'3596) described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) 1Y3596 TFP442 SPRINKLER ASSEMBLY THREAD INTO RETAINER suPpom- WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS FLUSH WITH CEILING EJECTION SPRING SOLDER COVER PLATE COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) EALING iSEMBLY RINKLER ENCHING AREA IPRESSION SCREW LEVER DER LINK BODY (1/2° NP CAP SADDL SUPPOF CUP WI1 ROLL FOR THREAC GUIDE PIN GUIDE P HOUSIN DEFLECL.,,, LEMENT FLECTOR 'ERATED rOSITION) TFP442 Page 2 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to all requirements of NSF/ANSI 61 - The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII/RFIII Concealed Cover Plates having factory- applied finishes. Sprinklers and Cover Plates are separately ordered. Refer to the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psP (70,6 LPM/bar5) Temperature Rating 160°F (71°C) Sprinkler 139°F (59°C) Cover Plate Vertical Adjustment 1/2 in. (12,7 mm) Finishes Refer to Ordering Procedure section Physical Characteristics Body ..............................Brass Cap ..............................Bronze Saddle ................. ............ Brass Sealing Assembly. . Beryllium Nickel w/TEFLON Soldered Link Halves ................Nickel Lever .............................Bronze Compression Screw ..................Brass Deflector ..................Copper or Brass Guide Pin Housing ..................Bronze Guide Pins .........Stainless Steel or Bronze Support Cup .......................Steel Cover Plate .......................Copper Retainer ...........................Brass Cover Plate Ejection Spring .... Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link-halves separate allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet 1FP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. TFP442 Page 3 of 6 WET PIPE SYSTEM Maximum Minimum Flow and Residual Pressure 2.3 Coverage Maximum Spacing Ordinary Temp. Rating Area1 160°F (71°C) Minimum ft x ft ft (m) Deflector to Installation Spacing Flow Pressure (m x m) Ceiling Type ft GPM psi (m) (LPM) (bar) 12x12 12 13 7.0 (3,7 X 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 13 7.0 7/8 to 1-1/8 in. (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per Concealed 8NFPA13Dor (2,4) 16x16 (4,9x4,9) 16 (4,9) 13 (49,2) 7.0 (0,48) 13R, or 13. Installed in 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 in. below bottom 20 x 20 20 20 16.7 of beam (6,1 x6,1) (611) (75,7) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requrement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated usingthe nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 GPM/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) - NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flowand Residual Pressure 2.3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area 160°F (71°C) I Minimum ft x ft ft Deflector to Installation Spacing Flow Pressure (mxm) (m) Ceiling Type ft GPM psi (m) (LPM) (bar) 12x12 12 13 7.0 (3,7 X 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14x14 14 14 8.2 7/8 to 1-1/8 in. (4,3x4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 (2,4) 16x16 (4,9x4,9) 16 (4,9) 15 (56,8) 94 (0165) 13R, or 13. Installed in 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 in. below bottom - 20 x 20 20 21 18.4 , of beam (6,1 x6,1) (6,1) (79,5) (1,27) Notes For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated us- ing the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 GPMfft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DISPOSABLE DEFLECTOR IN TIP PROTECTIVE CAP OPERATED POSITION SPRINKLER- SUPPORT CLIP ASSEMBI /OPERATE SPRINKLE COVER PLATE RETAINE 5/8"(15,9 r 1-1/8° (28,6 TFP442 Page 4 of 6 2-1/2' DIA. n- (63,5 mm) 1/2' (12,7 mm) THREADED FACE OF SPRINKLER 2u NPT ADJUSTMENT FITTING L1-7/8°±1/4° (47,6 mm 1/8 GAP ±6,4 mm) (3,2 mm) COVER- SPRINKLER- RETAINER SUPPORT CUP ASSEMBLY ASSEMBLY 3-3/16° DIA. (81,0 mm) I f MOUNTING 3/16° J SURFACE (4,8 mm) FIGURE 2 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS, PROTECTIVE CAP, AND ACTIVATED DEFLECTOR Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area A minimum discharge of 0.1 GPM/ft2 over the design area comprised of the four most hydrauli- cally demanding sprinklers for actual coverage areas protected by the four sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 feet for a 20 ft x 20 ft coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only. Therefore, do not apply pres- sure to the fusible Link Assembly. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under-or over-tightening the Sprinkler. Re- adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 18 SPRINKLER WRENCH Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 3, install and tighten the Sprinkler! Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 in. ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." TFP442 Page 5 of 6 Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFlI Residential Concealed Pendent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 in. (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Res- idential Concealed Pendent Sprinkler, P/N 51-112-1-160 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFIl/RFllI Concealed Sprinkler Cover Plate Assembly, (specify finish), P/N (specify): Ivory (RALI015) ...............56-204-0-135 Beige (RAL1 001) ..............56-204-2-135 Pure White (RAL9O1O). ......... 56-204-3-135 Signal White (RAL9003). ........ 56-204-4-135 Grey White (RAL9002) .......... 56-204-5 -135 Brown (RAL8028)..............56-204-6-135 Black (RAL9005) ..............56-204-7-135 Brushed Brass ................56-204-8-135 Brushed Chrome ..............56-204-9-135 Brass .......................56-204-1-135 Custom Paint .................56-204-X-135 *Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265