Loading...
HomeMy WebLinkAbout152 SEQUOIA AVE; ; FPR2018-0138; PermitJ1:iliISTIti:1Ls]i4l (ity of Carlsbad Print Date: 10/24/2024 Job Address: 152 SEQUOIA AVE, CARLSBAD, CA 92008-4057 Permit Type: FIRE-Construction Residential Work Class: Parcel if: 2060110800 Track if: Valuation: $236,435.50 Lot if: Occupancy Group: Project #: ifof Dwelling Units: Plan if: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check if: Plan Check if: Permit No: FPR2018-0138 Status: Closed - Finaled Single Family Fire Sprinkli Applied: 07/24/2018 Issued: 08/08/2018 DEV2017-0034 Finaled Close Out: 08/14/2019 Final Inspection: INSPECTOR: Fieri, Dominic Wong, Cindy Project Title: CARR RESIDENCE Description: CARR RESIDENCE -SPRINKLER NFPA 13D (13 HEADS) FPContractor: MCMAHON FIRE PROTECTION 3620 GEORGIA ST, if APT 3 SAN DIEGO, CA 92103-4639 (619) 992-3034 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov IN Da oo Hydraulics Summary Sheet Project Information Calculation Date: 7/18/2018 9:16 PM rCARR RESIDENCE system ID drawing ref 152 SEQUOIA AVE CARLSBAD CA. 92006 contract# 2018 rgn4r,4,r Trif#iinafi,in McMahon Fire Protection Inc. 16458 Avenida Venusto unit A San Diego Ca. 92128 calculated by Todd L. McMahon telephone 619-992-3034 fax email mcmahonfiregmaiI.com i.— Sprinklers in Remote No. Mfgr Mod SIN# Size K [ 2 1 RELIABLE I RFC49 I RA0616 1 7/16 4.90 120 - 110 100 90 -- 80 —'- 70 40 50— CL 40, 30 20-7 10 oi 05 building 1 STORY construction VB occupancy R3 authority CITY OF CARLSBAD Hydraulics Criteria - density .05 GPM/1t2 system type WET design std NFPA 13D remote area KITCHEN/FA hazard LIGHT spr coverage MW sprs flowing 2 curve clnta, Tact, static pressure 71.28 psi residual pressure 20.00 psi quantity flowing 1100.0 GPM date & time of flow test Per Carlsbad Water Dept location of flow test 10 15 20 25 30 35 40 Water Flow (GPM) © Copyright 2016 Sigma Development Group, Inc. Page 1 of 4 Da Supply Analysis CARR RESIDENCE Sprinkler Flow: 26.OGPM Additional Flows: 5.0 GPM Hose Flow at Zero: None Total System Flow: 31.OGPM Maximum velocity in pipe 0-1 is 12.8 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 10 16.00 Sprinkler 4.90 13.00 7.07 13.03 9 16.00 Sprinkler 4.90 13.00 7.04 13.00 5 3.00 Hose Flow 18.82 5.0 0 Copyright 2016 Sigma Development Group, Inc. Page 2 of 4 8OO D Pipe Information ashboa,dHydraull s CARR RESIDENCE From Elevi I ID Pipe Flows Length C Value [Total (Pt) psi [ ft I Added GPM Inside Diameter Fittings i Notes Fitting ft Elev (Pe) psi Elev2 Friction Loss Total Total ft [Frict (PQ psi I To ft Type psi/ft 0 0.00 1" Type K Len 12.01 C = 150 Pt 1) 49.760 0.9950 E,T,GV Ftg 9.3 Pe 0.000 1 0.00 UN 31.0 0.25101 Pf 5.356 Total 21.3 Total Pressure at Node 0) 55.116 psi 1 0.00 1' Type L Len to] = 150 Pt 2) 43.623 r Hersey Residential Fire Meter Model REM 30: Loss = 1.0300 RFM Ftg 0.0 Pe 0.000 5.92 2 0.00 UN 31.0 0.21212 Pf 0.212 Total 1.0 Total Pressure at Node 1) 49.760 psi 2 0.00 1° Type L Len 2.01 c = 150 Pt 3) 43.198 1.0300 Ftg 0.0 Pe 0.000 3 0.00 UN 31.0 j2 Pf 0.424 Total 2.0 Total Pressure at Node 2) 43.623 psi 3 0.00 1" Type L T Len 2.0 1 = 150 1 Pt 4) 32.275 Zum 1° Reduced Pressure Zone Assembly Model 975XL2: 1.0300 RPZ Ftg 0.0 -------j Pe 0.000 Loss= 10.50 4 0.00 UN 31.0 0.21212 Pf 0.424 Tota2.0 Total Pressure at Node 3) 43.198 psi 4 0.00 11, CPVC 1.1010 4E Len 51.01 Ftg 28.3 C = 150 1 Pt 5) 18.819 Pe 1.300 Pf 12.156 5 3.00 UN 31.0 0.15332 Total 79 Total Pressure at Node 4) 32.275 psi 5 3.00 1" Type L Len Pt 6) 12.482 1.0300 CV Ftg 6.9 Pe 3.900 6 12.00 UN 26.0 0.15325 Pf 2.438 Total 15.9 Total Pressure at Node 5)18.819 psi 6 12.00 1" CPVC 1.1010 Len 4.01 Ftg 0.0 C=150 Pt 7) 10.305 Pe 1.733 Pf 0.443 7 16.00 UN 26.0 Total o117 Total Pressure at Node 6)12.482 psi 7 16.00 1" CPVC 1.1010 E Len 7.01 Ftg 7.1 C = 150 Pt 8) 8.747 Pe 0.000 Pf 1.559 8 16.00 UN 26.0 0.11077 Total 14.1 Total Pressure at Node 7)10.305 psi 8 16.00 ?CPVC Len 58.0 [ C = 150 Pt 9) 7.040 1.1010 2E,T, Ftg 26.6 Pe 0.000 9 16.00 CM 10.4 6TR 0.02019 Pf 1.707 Total 84.6 0 Copyright 2016 Sigma Development Group, Inc. Page 3 of 4 á8 Dwh OO Pipe Information CARR RESIDENCE Pipe ID Flows I Length ft I I I C Value 1 Total (Pt) psi I I From ft Added GPM Inside Diameter Fittings I Notes I I Fitting ft I I Elev (Pe) psi To EIev2 Type in I Friction Loss [ psi/ft j Total b0tal ft Frict (Pt) psi Total Pressure at Node 8) 8.747 psi 8 16.00 1" CPVC 1.1010 E,3TR ILen 28.0 I Ftg 10.8 C = 150 I -•------------I It 10) 7.068 Pe 0.000 1.678 10 16.00 CM 15.7 0.043261Pf -ii-1 rTotal Total Pressure at Node 8) 8.747 psi 10 16.00 1"CPVC 1.1010 T Len 13.0 Ftg 5.0 j C = 150 j— J Pt 9) 7.040 Pe 0.000 0.029 9 16.00 CM 2.6 0.00160jPf Total _lij Total Pressure at Node 10) 7.068 psi 0 Copyright 2016 Sigma Development Group, Inc. Page 4 of 4 Bulletin 006 Rev. L June 2018 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL). Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC58 and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link operating element. Sprinklers with a 165°F (74°C) tempera- ture rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are intermediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust- ment. Model RFC58and RFC76 sprinklers allow 3/4"(l9mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. Model IRFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 5 C Model RFC76 Model RFC Cover Plate Sprinkler Model p Nominal K-Factor gpm/psilm 0/minIbar1 ) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14x 14(4.3x4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL RA3211 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL RA3212 RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0,25% Lead content). www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 112" NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor. Nickel Alloy Solder Link Sprinkler Body". Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals ctJLus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions 2-5/16' (58 mm) Threads Dia. Body Cup Tower 1-3/4° (44 mm) +1- 1/4' (6 mm) Fusible Link \\\- 'I' / Nominal face of fitting to ceiling Deflector (retracted) 3/16° i— (5 mm) Pin (extended) I I II Deflector (extended) 3-5/16" (84 mm) Dia. Ceiling Model RFC Cover Plate Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressuret11 Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm'sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. - Bulletin 006 Rev. L Page 2of8 June 2018 Reivabjd www.reliablesprinkler.com -- Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure; 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly; Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) lfiliiiVAti .11 Model RFC43 & RFC43LL Sprinkler Components and Dimensions , 2-5/16° (58 mm) Threads - Dia. Body Cup - Tower Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) - 1-3/4"(44 mm) +1- 1/4° (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate 3-5/16 (84 mm) Dia. 3/16"(5mm) Ceiling Model RFC43 & RFC43LL. Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area (Z Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 15x15 12 7.8 (4.6 x 4.6) (45) (0.54) 16x16 13 9,1 (4.9 x 4.9) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) 20x20 21 23.8 (6.1x6.1) (79) (1.64) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpmlsq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. L Page 3 of 8 June 2018 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2' NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Bottom View / Model RFC49 & RFC49LL Sprinkler Components and Dimensions iIT1RC Threads 2-5/16° (58 mm) Dia. Body ______________________ Cup Tower 1-3/4° (44 mm) +1- 1/4° (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector(retra 3/16" (5 mm) ' •• M r Pin (extended) Deflector (extended) Model RFC Cover Plate 3-5/16" (84 mm) Dia. V, Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressuret1t Max. Coverage Area Flow Pressure ft. xft. gpm psi (m x m) (I/mm) (bar) 16x16 13 7.0 (4.9 x 4.9) (49.0) (0.48) 18x18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20x20 20 16.7 (6.1x6.1) (75.7) (1.15) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table 0 above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. L Page 4 of 8 June 2018 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2 NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast-response Mm. Spacing: 8 ft. (2.4 m) Temperature Ratings Material Specifications Ordinary: Thermal Sensor. Nickel Alloy Solder Link 165°F (74°C) sprinkler Sprinkler Body: Brass Alloy 135°F (57°C) cover plate Levers: Bronze Alloy Intermediate: Yoke: Brass Alloy 212°F (1 00°C) sprinkler Sealing Assembly: Nickel Alloy with PTFE 165°F (74°C) cover plate Load Screw: Bronze Alloy Towers: Copper Alloy Cover Plate Pins: Stainless Steel Model RFC Cover Plate Deflector Chrome Plated Bronze Alloy Cup: Steel Sprinkler Wrench Model FC Listings and Approvals cULus Listed Bottom View Model RFC58 Sprinkler Components and Dimensions 2-5/16 (58 mm) Dia. Threads Body Cup Tower Deflector (retracted) (48 mm) +1- 3I8 (9 mm) Fusible Link _______ Nominal face of fitting to ceiling Pin (extended) II Deflector (extended) Model RFC Cover Plate 3-5/16 (84 mm) Dia. i_3116(5mm) Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria _1r1 Minimum Flow and Residual Pressure01 Max. Coverage Area (Z Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5x5.5) (68.1) (0.66) 20x20 20 11.9 (6.1x6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. -bi Bulletin 006 Rev. L Page 5of8 June 2018 ReIua www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast-response Mm. Spacing: 8 ft. (2.4 m) Temperature Ratings Material Specifications Ordinary: Thermal Sensor Nickel Alloy Solder Link 165°F (74°C) sprinkler Sprinkler Body: Brass Alloy 135°F (57°C) cover plate Levers: Bronze Alloy Intermediate: Yoke: Brass Alloy 212°F (100°C) sprinkler Sealing Assembly Nickel Alloy with PTFE 165°F (74°C) cover plate Load Screw: Bronze Alloy Towers: Copper Alloy Cover Plate Pins: Stainless Steel Model RFC Cover Plate Deflector Bronze Alloy Cup: Steel Sprinkler Wrench Model FC Listings and Approvals cULus Listed Bottom View Model RFC76 Sprinkler Components and Dimensions J.1tI(Z Threads Body Cup - Tower - Fusible Link Deflector (retracted) Pin (extended) Deflector (extended) - 2-5/16° (58 mm) Dia. -7/8" (48 mm) 3/8 (9mm) Nominal face of fitting to ceiling +1- \\\\\\\ Model RFC Cover Plate 3/16(5 mm) Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure(i) Max. Coverage Area R Flow Pressure ft. xft. gpm psi (m x m) (1/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1x6.1) . (128.7) (1.4) Notes: 1, For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. L Page 6 of 8 June 2018 www.reliablesprinkler.com Cover Plate Finishes() Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paintt2 Notes: I I I Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Min. to Min. to Max. Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Sprinkler Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model Model inch inch inch Ceiling()Ceiling Rating (mm) (mm) (mm) inch inch (mm) (mm) RFC3O, RFC3OLL, RFC43, RFC 3-5/16 2-5/8 1/2 1-1/2t02 1/2 to 1 135°F RFC43LL, (84) (67) (13) (38 to 51) (13t025) (57°C) RFC49, RFC49LL 135°F2) RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 1650F13t (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2' x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49 LL sprinklers are available in ordinary temperature classifica- tion for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC58 and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Bulletin 006 Rev. L Page 70f8 June 2018 www.reliablesprinkler.com Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Bulletin 006 Rev. L Page 8 of 8 June 2018 www.reliabtesprinkter.com (0 (0 (0 (0 (0 -.J 0 N.) C) Fire Protection Products Worldwide I Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties ha ving jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313 .....Upright 5.6K, 1/2"NPT TY323 .....Pendent 5.6K, 1/2" NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi/2 (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb ...................... ......... Glass Compression Screw .................Bronze Deflector ..........................Bronze JULY 2017 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 2-7/8" (73,0 mm) DIA. TFP172 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2' 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 (11,1 mm) NOMINAL 2 1-3/8 MAKE-IN ______ (50,8 mm) 2' (50,8 mm) (34,9 mm) I / WRENCH FLATS 1/2° NPT** DEFLECTOR* STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TV323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141 °C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8' DIA. (73,0 mm) 2-1/4° DIA. FACE OF (57,2 mm) 5/8(15,9 mm) SPRINKLER FITTING _____ \ FLUSH 3/8±5/16° 9,5±7,9 mm) 4/A I / ti/ MOUNTING / 1/8° J SURFACE/ -_ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" \ 1/2" (12,7 mm) (7,9±6,4 mm) FLUSH #(3,~2/ MOUNNG SURFACE/m) CLOSURE SERIES MOUNTING 1-3/8°(34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON SIN 370 5.6K UPRIGHT (1/2" NPT) TY313 371 5.6K PENDENT (1/2" NPT) TY323 * Use suffix "1° for ISO 7-1 connection; for example, 77-370-4-175-I TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED TOLYESTERC 135°F (57°C) Orange UPRIGHT 155-F (68-C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6 5.6 1/2" NPT PENDENT (TV323) ________________ 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange RECESSED PENDENT (TY313) Figures 4a and 5b 1,2,3,4 155-F (68-C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact TYCO Fire Protective Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ret. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2" NPT) 5/8° Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/N*77_X(X_ -xxx SPRINKLER TEMPERATURE FINISH I RATINGS 1 NATURAL BRASS - PURE WHITE (RAL9010)** POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 CHROME PLATED 135 135-F (57-C) 155 155-F (68-C) 175 175-F (79-C) 200 200°F (93°C) 286 286-F (141-C) ** Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is registered trademark of DuPont Fire Protection Products ItYil Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" guiellef SYSTEMSJJ Features APPLICATIONS: The Hersey Residential Fire Meter (RFM) is specifically designed for use in residential fire protection systems or combination systems that supply domestic plumbing needs and residential sprinkler fire protection service when installed as specified in NFPA 130 or NFPA 13R, (Standards for the installation of sprinkler systems in one and two family dwellings, manufactured homes and residential occupancies up to and including four stories in height). The RFM utilizes Herseys unique vertical turbine measuring element to measure flow rates comparable to traditional positive displacement meters, yet provides a measuring element that allows suspended particulate matter to pass through the element unobstructed when emergency flow requirements for water are demanded. No other meter provides more flexibility and dependability for measuring water accurately in residential fire suppression and domestic use applications. CONFORMANCETO STANDARDS: Each Hersey Residential Fire Service Meter is tested to assure compliance with ANSI/AWWA Standard C701, Class 1. Each male and female threaded RFM has UL Approval. EnviroBrass Il® options conform to the NSF 61 Standard. II 2" RFM 160 CONSTRUCTION: Hersey Residential Fire Water Meters consist of three basic parts: maincase, rotor assembly, and a permanently sealed register. Maincases and bottom plates are made of bronze for long service life. Rotor assemblies are thermoplastic, which is dimensionally stable and will not corrode. Retro Thrust® rotor design extends the life of the meter by dividing wear between two points: during low flow the tungsten carbide thrust bearing floats against a sapphire bearing surface; during high flowthe stainless steel shaft gently contacts a second sapphire bearing and during medium flow, the rotorfloats between the thrust bearings without contact. The measuring chamber is protected by an internal strainer with four times the effective straining area of the inlet pipe diameter. No external strainer is required. Fire service connections are easily recognized by the bright red register collar and lid on all visual read meters. Electronic meters are distinguished by the red collar and lense terminal cover on top of the Translator® register. Optional test ports are available on all 1-1/2" and 2" meters. REGISTER: The permanently sealed register has a unique L seal and heat treated glass to eliminate dirt, moisture infiltration and lens fogging. The totalizing register has a straight-reading odometer type display, a 360 test circle with center sweep hand and a low flow (leak) detector. All Hersey Meter models have electronic meter reading systems available for increased reading efficiency (see Meter Reading Systems). OPERATION: Water flows through the integral strainer and into the vertical turbine assembly. There, the direction of the water flow is directed by the hub into the rotor at the precise angle necessary for accurate measurement over the full range of flow rates. No straight pipe requirements apply before or after the meter. The turbine turns freely and rotates in direct proportion to the volume of water passing through the meter. The Hersey turbine operates more quietly than conventional disc or piston meters. MAINTENANCE: All Hersey Residential Fire Meters are designed and manufactured to provide long service life. The register on all sizes can be replaced without removing the meter from the line. Modular design and economical internal parts allow for inexpensive, speedy rebuilds. CONNECTIONS: Available with external (N.P.S.M.) straight pipe threads (ANSI B1.20.1) on 3/4" and 1" sizes; internal (NPT) pipe threads (ANSI B1.20.1) on 1-1/2" and 2" sizes. Ji:sI MODEL Residential Fire Meter (RFM) SIZES 3/4°, 1°, 1-1/2" and 2° STANDARDS Manufactured and tested to meet or exceed all applicable parts of ANSI/AV,WA C101, Class 1 Standard All Male and Female Threaded RFMS have UL Fire Service Approval SERVICE Cold water measurement with flow in only one direction OPERATING FLOW RANGE See Charts ACCURACY See Charts MAXIMUM WORKING PRESSURE 175 PSI Meets Hydrostatic Pressure Testing to 875 PSI. TEMPERATURE RANGE 33°F TO 130°F - MEASURING ELEMENT Rotor STRAINER 4 times the inlet pipe diameter of straining surface area with .080 perforations. REGISTER TYPE Straight reading, permanently sealed, magnetic drive with low flow indicator. Remote reading units optional. METER CONNECTIONS 3/40 and 1" external (NPSM) straight pipe threads, 1-1/2" size and 2" size available with internal thread (NPT) ends same nominal size as size of meter MATERIALS Maincase - bronze UNSC84400; Rotor assembly - thermoplastic; Strainer - stainless steel; Casing bolts - stainless steel ANSI B18. OPTIONS Meter case - EnviroBrassll® UNSC89520, Translator registers and AMR Systems rlrlrlR—L4u ffP2lIrir cvcTrAAi xi1 EEE1 Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" I1M1RLto1n IIhatW NM Meter Size 'Initial Dial * Capacity 'Initial Dial * Capacity 3/4U 10 Gallons 10 Million 1 Cubic Foot 1 Million 1' 10 Gallons 10 Million 1 Cubic Feet 1 Million 100 Gallons 100 Million 10 Cubic Feet 10 Million 2° 100 Gallons 100 Million 10 Cubic Feet 10 Million Meter Size Typical 1.0w Flow (95% Minimum) I Typical Operating Range (100% ± 2%) Maximum Continuous Operation I Maximum Intermittent Flow 3/4° 1/2 GPM 1 t 30 GPM 25 GPM 35 GPM 1° 3/4 GPM 1-1/2 to 50 GPM 35 GPM 55 GPM 1-1/2° 1-1/2 GPM 2 t 100 GPM 70 GPM 110 GPM 2° 2GPM 3 t 160 GPM 115 GPM 175 GPM [ J equal to one full revolution of the sweep hand. [D:i1i1whs 3/4" and 1" COMPACT RFM 1-1/2" and 2" COMPACT RFM with Internal NPT ends Meter Size 3/4" 1° 1 1-1/2" 2" Ends Threaded (screwed) Dimensions A 7-1/2" 9° 9" 10-1/2' B 5' 5-1/2" 5-3/4' 6-1/4" C 1-13/16" 2-3/8" 2-3/8" 3" Max.width 3-3/4" 4-1/4" 4-3/8" 5-3/8' Net weight 5* 7* 9* 14- * Weights are in pounds and are approximate. Head loss - 1-1/2" and 2" — 18 U) a 16 w 14 Cr CD 12 U) uj 10 (L 8 U- 06 (I) U) 4 0 '2 AAueller SysTE Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" C ~ V[I Warwr ifrima'n:ce II1ith.rim"an:ce i!I tII 102 IIIIIIIH___ IIIlIIIIII________ _____ 16 :1 w 14 w 98 cc 12 __IIIIIuIIII-------- LL iiuiuui.ri-mii.ii IIIIllluIl______CC 94 11111111111 11111111111 '2 0 5 10 20 30 40 50 RATE OF FLOW - U.S. GPM uuiumuu uuiuiuuui• I 'IIIuIuIuI.—____ : iuniiuuui• Iululuhul.----- m 0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160 RATE OF FLOW - U.S. GPM RATE OF FLOW - U.S. GPM *Performance curves are typical only and not a guarantee of performance. 0 90 Cr 88 86 w 0 5 10 20 30 40 RATE OF FLOW - U.S. GPM Accuracy - 1-1/2" and 2" 11 II 0 9 8 10 11 15 12a 12 15- 16 14 IiMuIIIPf cvcTrMcl1 X EEE1 Models RFM-30, RFM 50, RFM 100 and RIM 160 2 3 1 5 6 0- 7 13 cAJ©cJ@u EkL~iJ Models RFM-30, RFM 50, RFM 100 and RFM 160 rMueller SYSTEMS]) Ref. No. Description Model RFM-30 Model RFM-50 Model RFM-100 Model RFM-160 1 Lid (Plastic) Red 50377FS 50377FS 50377FS 50377FS 2 Red Clamp Band for Visual Register Red Clamp Band for Translator Register 50379FS B8602FS 50379FS B8602FS 50379FS B8602FS 50379FS B8602FS 3 Lid Seal Screw 19945 19945 19945 19945 4 Lid Nut 19999 19999 19999 19999 5 Sealed Registers (Specify unit of measurement) 3/40 M.I.P. Ends See pages 7.7-7.8 6 RFM 30 Top Case (7-1/2 length): 50466(A) - - - 6 RFM 50 lop Case (9" length): 1° M.I.P. Ends RFM 100 Top Case (90 length): - 50566F5(B) - - 6 1-1/2°F.l.P.Ends - - 50776FS(C) - 6 RFM 160 lop Case (10-1/2 length): 2" F.I.P. Ends - - - 50866FS(D) 7 Rotor 50471 50571 50771 50871 8 Inlet Hub 50467 50567 50767 50867 9 Lower Bushing 50374 (2) 50574 (2) 50574 (2) - 10 Interior Screw 98394 (4) 98394 (4) 98394 (4) 98394 (4) 11 Strainer (Metal Ring) 50480 50580 50780 50880 12a Rubber Gasket - B7647 50786 C5488 12b Liner 50365 87646 50766 C5491 13 Inlet Plug Assembly 50493 50493 50493 53105 14 Bottom (Bronze) only C6592 C6593 C6594 03594 15 Case Washer A51792 (4) A57792 (4) 98378 (4) 98378 (4) 16 Case Bolt 90010 (4) 90010 (4) 90073 (4) 90073 (4) Bushing Spacer - - - 53114 Bushing - - - 54915 (2) Sapphire Thrust Bearing (Case) 98371 98371 98371 98371 Complete Interior 50477F5 50517FS 50777F5 50872F5 Bearing Adhesive* - - - - Adapters**: 3/4° Adapter 3/4' Adapter Washer 10 Adapter 1" Adapter Washer 1-1/2° Female Adapter 2° Female Adapter 95046 95014 - - - - - - 95063 95064 - - - - - - 95095 - - - - - - 95195 Order 3/40 Adapter 95046 and Adapter Washer 95038 to replace standard 3/40 disc meter, 90 long. Order 10 Adapter 95063 and Adapter Washer 95064 with Top Case 50566 to replace standard 10 disc meter, 10-3/4" long. Order 1-1/2° Adapter 95095 with Top Case 50776 to replace 1-1/2° female end meter installed with union connections. Assemble to length of 12-5/8°. 0: Order 2" Adapter 95195 with Top Case 50866 to replace stanJard 20 Female End disc meter, 15-1/4 long. *purchase locally. Use a cyanoacrylic adhesive, such as Loctite Super Bonder #30-13, Eastman #916, Permabond or Aron Alpha. **Must be ordered separately. Not an integral meter component. NOTE: If more than one part is required, quantity is noted after part number (in parenthesis). II _.4MuIIr cvcTFAAcil w@64 Visual Register Options Cubic Feet U.S. Gallons RFM Model Register Part Numbers Internal Ratio Relation to other Registers Register Part Numbers Internal Ratio Relation to other Registers RFM-30 B79821FS 551.99 -4% (in relation to B79825) 879813FS 738.92 -4% (in relation to B79817) RFM-30 879822FS 546.34 -3% (in relation to 879825) B79814F5 731.88 -3% (in relation to B79817) RFM-30 B79823FS 540.85 -2% (in relation to B79825) 879815FS 723.79 -2% (in relation to B79817) RFM-30 B79824FS 536.22 -1% (in relation to 879825) 879816F5 715.86 -1% (in relation to B79817) RFM-30 B79825FS 530.07 - B79817FS 709.01 - RFM-30 B79826F5 523.96 +1% (in relation to B79825) 879818F5 702.61 +1% (in relation to B79817) RFM-30 B79827FS 519.6 +2% (in relation to 879825) B79819FS 694.85 +2% (in relation to B79817) RFM-30 I B79828FS 514.2 +3% (in relation to B79825) B79820F5 688.55 +3% (in relation to 879817) RFM-50 879861FS 269.44 -4% (in relation to 879865) B19851F5 360.58 -3% (in relation to B19854) RFM-50 879862FS 266.44 -3% (in relation to B79865) B79852FS 356.41 -2% (in relation to B79854) RFM-50 B79863FS 264.51 -2% (in relation to B79865) B79853F5 353.17 -1% (in relation to B79854) RFM-50 B79864FS 262.07 -1% (in relation to B79865) 879854FS 349.42 - RFM-50 B79865FS 258.83 - 879855FS 345.93 +1% (in relation to 879854) RFM-50 B79866FS 256.52 +1% (in relation to B79865) B79856F5 342.53 +2% (in relation to B79854) RFM-50 879867FS 254 +2% (in relation to 879865) B79857FS 339.04 +3% (in relation to B79854) RFM-100 B79901FS 1973.95 -3% (in relation to 879904) B79891FS 2664.16 -3% (in relation to B19894) RFM-100 879902FS 1951.68 -2% (in relation to B79904) 879892F5 2646.98 -2% (in relation to B79894) RFM-100 B79903F5 1935.27 -1% (in relation to B79904) B79893FS 2605.61 -1% (in relation to B79894) RFM-100 B79904F5 1912.65 - B79894F5 2586.61 - RFM-100 B79905F5 1901.98 +1% (in relation to 879904) B79895F5 2554.55 +1% (in relation to B79894) RFM-100 B79906F5 1882.77 +2% (in relation to B79904) 879896FS 2526.66 +2% (in relation to 879894) RFM-100 B19907F5 1862.97 +3% (in relation to B79904) B79897FS 2505.78 +3% (in relation to 879894) RFM-160 B79941F5 604.34 -3% (in relation to B79944) 879931FS 808.31 -3% (in relation to 879934) RFM-160 B79942FS 598.37 -2% (in relation to 879944) B79932FS 800.5 -2% (in relation to B79934) RFM-160 B79943FS 592.81 -1% (in relation to 879944) B79933F5 192.41 -1% (in relation to B79934) RFM-160 B79944FS 587.03 - 879934FS 184.64 - RFM-160 B79945FS 580.58 +1% (in relation to B79944) B19935FS 775.87 +1% (in relation to 879934) RFM-160 879946FS 575.56 +2% (in relation to 879944) B79936FS 768.47 +2% (in relation to 879934) .. $1i.PI Translator Register Options for RFM 30 to 160 AINUOI'leF SYSTEMS]] Ref Description RFM-30 RFM-50 RFM-100 RFM-160 1 Translator Register* Gallons Cubic Feet Specify Electronic Reading Value 4, 5, or 6 Wheel 035231mm 035232xxx 035241)m 035242)z D35251xxx D35252xxx D35261xxx 035262mm 2 Red Clamp Band (Plastic) Translator Only B8602FS B8602FS B8602FS B8602FS 3 Clamp Band Seal Nut 19999 19999 19999 19999 4 Clamp Band Seal Screw 19945 19945 19945 19945 5 lens Terminal Cover Red B8447FS B8447FS B8447FS B8447FS 6 Terminal Lug Screw 98197 (3) 98197 (3) 98197 (3) 98197 (3) 7 Wall Pad 11234 11234 11234 11234 8 Pit Pad 11240 11240 11240 11240 9 TrueRead (not shown) C6551G C6551G C6551G C6551G 10 1,000 Spool of Wire (not shown) A5755 AS755 AS755 AS755 *Call Mueller Systems Customer Service for appropriate Translator Register and AMR device part number. © Mueller Systems 03125/2011 EtIP110f cvcTrAAczii1 This page intentionally left blank. 1 WILKINS Reduced Pressure Principle Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Standards Compliance ASSE® Listed 1013 IAPMO® Listed UL® Classified (less shut-off valves or with OS&Y valves C-UL® Classified CSA® Certified B64.4 AWWA compliant C511 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA 425-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers NorylTM, NSF Listed Springs Stainless Steel, 300 series Features Sizes: 3/4", 1°, 1-1/4", 1-1/2°, 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Options (Suffixes can be combined) El - with full port QT ball valves (standard) L - less ball valves, male pipe thread O U - with union ball valves 0 MS - with integral relief valve monitor switch 5 - with bronze °Y type strainer BMS - with battery operated monitor switch FDC - with fire hydrant connection; 2° only E] FT - with integral male 450 flare SAE test fitting TCU - with test cocks up V - with union swivel elbows (3/4° & 1°) SE - with street elbows (3/4° & 1) Accessories O Air gap (Model AG) 0 Repair kits E] Thermal expansion tank (Mdl. XI) E] Soft seated check valve (Model 40XL) Shock arrester (Model 1250XL) 0 QT-SET Quick Test Fitting Set O Ball valve handle locks Relief Valve discharge port: 3/4"-l" - 0.63 sq. in. 1 1/4"-2" - 1.l9 sq. in. Dimensions & Weights (do not include pkg.) ___________ _____________ DIMENSIONS _(approximate) MODEL 975XL A C D E F G WITH BALL SIZE VALVES in. mm in. mm in. mm in. I mm in. I mm in. I mm in. I mm in. I mm lbs. I kg 3/4 20 1 12 305 1 73/4 197 21/8 54 3 76 31/2 89 5 1127 161/8 410 12 5.5 1 25 13 330 73/4 197 21/8 54 3 76 31/2 89 5 127 173/8 441 14 6.4 11/4 32 17 432 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 229/16 573 28 12.7 11/2 40 173/8 441 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 241/16 611 28 12.7 2 50 181/2 470 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 261/2 673 34 15.4 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. C Date: 6/14 Document No. BF-975XL Product No. Model 975XL www.zurn.com I Page 1 of 2 Flow Characteristics 0 Rated Flow (established by approval agencies) MODEL 975XL 3/4", 1", 1 1/4",11/2" & 2" (STANDARD & METRIC) FLOW RATES (us) w a. 1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 ______________ 0. -1 1 _________ 137 - (I) m 20 4(32mm) p. 103 ______ U) ______ 0 —J 15 W cc _____ _____ _____ _____ _____ 69 10 Cl) U) w ______ ______ ______ ______ ______ 35 5 Q. 0 50 100 150 200 250 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. CENTRAL STATION ALARM PANEL BATTERY MONITOR Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 1/8" 1 1 2 3 1/4' 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 52 78 105 167 PROTECTIVE ENCLOSURE 1 /fl ) -" U WATER METER\ L1I AIR GAP / :T( DRAIN DIRECTION OF FLOW FLOOR DRAIN DIRECTION OF FLOW CD INLET SHUT-OFF INDOOR INSTALLATION OUTDOOR INSTALLATION (Shown w/optional BMS) Specifications The Reduced Pressure Principle Backflow Preventer shall be shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NoryPM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. It installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Back- flow Preventer shall be a ZURN WILKINS Model 975XL. Zum Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 112 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2