Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3913 SHERIDAN PL; ; FPR2019-0217; Permit
(City of Carlsbad Print Date: 10/24/2024 Job Address: 3913 SHERIDAN P1, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2060424700 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPR2019-0217 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 11/04/2019 Issued: 02/05/2020 Finaled Close Out: 10/07/2020 Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Project Title: Description: SHERIDAN PLACE RESIDENCE -REVISED PLANS FOR NEW 13D SPRINKLER SYSTEM (28 HEADS) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 9475 CHESAPEAKE DR 9475 CHESAPEAKE DR SAN DIEGO, CA 92123-1336 SAN DIEGO, CA 92123-1336 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 FIRE Plan Review Per Hour - Office Hours $204.00 Total Fees: $575.00 Total Payments To Date: $575.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov y 2-OM O24 [Hydraulic Overview Job Number 19-0041 Report Description: 2 HD CALC (1) iob Jab Number I Design Er0lneer 19-0041 MIGUEL DLI drones Job Wane: SHERIDAN PLACE RESIDENTIAL FAX 619-586-6364 619-588-6805 Address 1 State Certthcatiorflicense Number 3913 SHERIDAN PLACE 684025 Address2 CARLSBAD, CA 92008 Address 3 diii CARLSBAD FIRE DEPT. Job Slt&edidjrN System Density Area otdpplicatsin 0.0509pm/ft2 512.00ft' (Actual 357.50ft2) Nest Derrrarstina Spnirdttet Data Prose Streams 4.9 K-Factor 13.00 at 7.039 5.00 000ersge Pe,Sptinkter 256.00ft2 NurSer Ot Spntntders Catutated na.nceaspr050esuacuaiea 2 0 SySem Pressure Demand 42.864 Sylasm FDa, DendOst 27.20 Total Depend 32.20 @42.864 Pressure Resist +29.135 (40.5%) Supplies a - Check Paint Gauges -. Node Name Flow(pm) Hose Fiowlppml Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(ppm) 1 Water Supply 1200.00 5.00 72.000 71.000 B4O.R. 28.477 5.1 27.20 190041 SHERIDAN PLACE RE3SIDENCE_ALL LVLS FIRE SPRl Water.Supply at Node 1(1200.00,5.00,72.000,71.000) 100- 90 80 tatic Pressure 72.000 70 f "200.00 @ 71.000 60 50 - - streamsL30 40 2.864 r32.2Ohose mand curve 20- 10- jLll• .IWLL• jjLLLL• •ILLLLW •LUJJJJJ .L.W.UJ.L 11111111 111111 I 2250 2500 P075010 1250 1500 1750 2000 Water flow, gpm , © M.E.P.CAD, Inc. 0,1 AutoSPRINK 2019 05.1.14.0 10/31/2019 2:42:07PM Pagel. [!jydrau1icSumn1ary - Job Number: 19-0041 Job I O. A_O.e t) Job Number Daorgrr Rwnrner 19-0041 MIGUEL DLI Jab Name. SHERIDAN PLACE RESIDENTIAL We Certificatioru'Ucerae Number 684025 Address I 3913 SHERIDAN PLACE AlA CARLSBAD FIRE DEPT Address 2 Job Site/Bvitdor9 - - CARLSBAD, CA 92008 - Address 3 Drauolrrg Name 190041—SHERIDAN PLACE RESIDENCE—ALL LVLS_FIRE SPRI System Remote Area(s) Most Demarsbng Sp,inldor Data 000rulonoY HA brotro 4.9 K-Factor 13.00 at 7.039 j 2 HD CALC Hose njroruaenoeott Source Presouee ottoaotApplication 5.00 O.OsOgpmlft2 512.00W (Actual 357.50f1a) Additional Hose Hupjats Number CI Sprkrtdero Calcitated Number Of Nozzles Catoviatarl Coverage Per Sprirrider Node Flow(gpm) 2 0 256.00W AAtopeeh eesUes: Presoure For Remote Area(s) Adjacent To Moot Remote Area Total noseSbeama 5.00 Sestamptowoemarrd TotalWaterRequ(red)InvindingHoseotJIovvanoe) 27.20 32.20 Maobrrum Pressure Uitalanoe In Loops 0.000 Masimum Velvody Above Ground 14.54 between nodes 7 and 8 Maoimum Vetocity Under Ground I 9.17 between nodes 1 and 2 VolunnaovpaoltnotvtetProoe VotumeoapaolyolbryPipos 18.92gaI Supplies Hose Flow Static 11 Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) 1 Water Supply 5.00 72.000 71.000 1 1200.00 f 71.999 32.20 42.864 29.135 Contractor Cvntraotor Nunter CoruaH Rarer. 1 SYMONS FIRE PROTECTION Coruact Tote Name otcontrootor Phone Esterrovon - SYMONS FIRE PROTECTION FAd 6195886364 12155 PAINE PL 6195886805 POWAY, CA 92064 MDELATORRE@SYMONSFp.COM Add... 3 DAb-Sot , © M.E.P.CADr Inc. AutoSPRINK 2019 v15.1.14.0 10/31/2019 2:42:10PM Page 2 IHydrau1ic'GraPh Job Number: 19-0041 Rnnrt fl,rinti,n I-lfl C'Ai C (1 Water Supply at Node I 100-: 90— 80- -Static Pressure 72.000 0C)00 @ 71.000 60- 0) 0. 50— CL 7.20 42.864 32.20 with hose streams 40- 30— item demand curve 20- 10 — 0—..l_LLLU_LIIIIIH1I 111111111 IIIIIIIl IIIIII.[1 IIlIIIL____L_ 11111111 liii liii 1150 oo 750 1000 1250 1500 1750 2000 2250 2500 Water flow, gpm ydUG,P0 Water Supply at Node 1 StaTic. PTeSSLfl 72.000 Re&dI P-- 71.000 @ 1200.00 A-1 M. Pres$U,eatTim,ofTesl 71.999 @32.20 42.864@27.20 . Sy.et,d I(Ckdg H$ 42.864 @ 32.20 , © M.E.P.CAD, Inc. M AutoSPRINK 2019 V15.1,14.0 . 10/31/2019 2:42:12PM Page 3 1111Hydraulic Graph Job Number: 19-0041 Paunnrt flcus,-rintnn' I-lfl ral C 11\ B.O.R. 100-: 90— 80— Static Pressure 72.000 120000 © 71.000 70- --- ____ _____ ______ -- ________ — 60—- 10 a 40-- 30 27.20 28.477- 32 . 20 with hose streams 20— item demand curve 10- 0-1w UULLLLI tIJ.I.J..LI.J.1IIllIII IllIllIll IIIlllIl 111111111 IIIIIIIL 1111111 I 11111 I III 250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow, gpm Hydtautc Gsa Pt, 6.O.R. Static: Pcesetze N/A Residual Pressure N/A *vailabte Pressure at Time of Test N/A 28.477 @ 27.20 Stuermsutluaurc,00 tt050 clGcaocc at 500,55) 28.477 @ N/A © M.E.P.CAO, Inc. J AutoSPRINK 2019 05.1.14.0 10/31/2019 2:42:12PM Page 4 [Summary Of Oitfiowing Devices I Job Number 190041 , © M.E.P.CAD, Inc. ill AutoSPRINK 2019 v151.14.0 10/3112019 2:42:13PM Page 5 INode Analysis .. I Job Number: 19-0041 - Keport uescrlptlon: 2 MU UALL (1) Node Elevation(Foot) Fittings Pressure(psi) I Discharge(gpm) i 1 -4-6 S 42.864 27.20 iOu 19-0Spr(-8.396) 8.396j 14.20 2 1 -30 31.853 -- ,.-. ::-9 ... . - 67 1. ............ t.. - cPi1'-9)P.. ..................8.477 - - -- _..5 - - !:P). ... . - .. . 9-61(3-0) - 21.842 H .7 - 19-67(3-0) ---- 19"-§ T(T-0 11.682 ) .............. 8 568j , © M.E.P.CAD, Inc. M AutoSPRINK 2019 v15.1 .14.0 10/31/2019 2:42:1 5PM Page 6 JJ Hydraulic Analysis ... I Job Number: 19-0041 Report Description: 2 HD CALC (1) Pipe Type Diarnetr Flow Velocity HWC Friction Loss Length Pressure Downstream Elevaticn Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length - Routel ..... DR 0.8740 13.00 6.95 150 0.094407 14-6Pf 1.747 100 19-0 13.00 4.9 7.039 Sprinkler, 4--0 Pe -0.217 8 19-6 8.568 E(4-0) i 18-6 jPv BL 0.8740 27.20 14.54 150 0.369926 5-5Pf 3.113 8 19-6 14.20 8.568 Flow (q) from Route 2 I 3-01Pe 7 19-6 11.682 T(3-0) 8-5!Pv FM -0.8740 17.40 930 - 150 . 0i618..7. 253jPf 5.871 7 19-6 11.682 11-0Pe 4.335 5 9-6 21.888 2E(4-0), T(3-0) 36-3 Pv FR ......1.1010 .....17....................P.1016_._ -- 2.904 5 9-6 9.80 21.888 Flow (q) from Route 3 .10-2Pf 14 -0lPe 3.685 4 1'O 28.477 E(5-0), 2f, 31r(1'-O), CV(5-0), 242 Pv cplg(V-0), B.O.R. L. . . 1.Q.P - . 27.20 108 10 0.170235 ............... 5-0IPf 0.851 4 1-0 28.477 Pe 1.739 3 4-0 31.067 5-0 Pv UG -- . 1.5050 . 27.20 - 4.91 150 . - . . 300iPf 0.787 3 -3-0 31.067 Pe 2 -3-0 31.853 30-0;Pv UG 1.1010 27.20 9.17 150 0.120163 3-0Pf 10.360 2 4-0 31.853 Pe 0.650 1 4-6 42.864 wrv(-10.000) s 3'-0iPv 5.00 Hose Allowance At Source 1 32.20 Route ..... DR 0.8740 14.20 7.59 150 0.111135 0-6Pf 0.389 101 14.20 4.9 396 Spnkier, j 3-0Pe -0.217 8 19-6 8.568 1(3-0) I 3-6Pv =. ..... Route 3 ..... 80-1 Pt FR 1.1010 --.-0 3.30 150 0.018187 2'-6Pf 0.045 6 9-6 9.80 21.842 Flow (q) from Route 4 Pe 5 9-6 21.888 2-6'Pv - Route 4 ..... FM - 0.8740 9.80 5.24 10 . . - 0055990 - .. 5.825 7 19-6 17.40 11.682 Flow (q) from Route 1 24'-OPe 4.335 6 9-6 21.842 6Tr(1-0), E(7-0), 1(3-0), 2E(4-0 104-1 Tv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) k C ValUe Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor - -. 1.16 -- 1.33 1.51 , © M.E.P.CAD Inc. L9 AutoSPRINK 2019 v1 5.1.14.0 ifli1i7fliQ 41fPM D.. 7 IHydrau11c Analysis Job Number 190041 Report Description: 2 HD CALC (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foo Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt i Total pressure at a point n a pipe DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90 Elbow UG Underground Pf Pressure loss due to friction between points EE 45 Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 221W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90 FireLock(TM) Elbow fEE 45 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet Pry Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90 Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. AutoSPRINK 2019 v15.1.14.0 10/31/2019 2:42:16PM Page 8 1111Hydraulic Ovdirview Job Number: 19-0041 Report Description: 1 HD CALC (1) Job Job Nw,ter oeelo,r Errerneer 19-0041 MIGUEL DLT Job Name Phone FAX SHERIDAN PLACE RESIDENTIAL 619-588-6364 619-588-6805 Address I State csrtificatlorhLicense NL,rrbar 3913 SHERIDAN PLACE 684025 Address 2 CARLSBAD, CA 92008 554 CARLSBAD FIRE DEPT. Address 3 Job Srte/Oraidirç System L)onsdo Ares alAppboation 0.050gpm/ft2 400.00ft2 (Actual 163.00ft2) Most penrarrdbtg sprurAs, Data Hose Streams 4.9 K-Factor 20.00 at 16.660 5.00 Cuae,aae Per Spltntde, Number 01 Spnntdsrs Caicubted - SrrSe, MSpretue,s C.- 400 .Ooft 2 1 0 SvatsrrrPreuurs Demaro 45.897 ovbemFb,eborr.rd 20.00 TSar Demand 25.00 @45.897 Pressure Aesdt +26.102 (36.3%) Supplies . Check Point Gauges Node Name Flcw(ppml Hose Flow(gpm) Static(psil Residua(osi) Identifier Pressure(psi) K-Factor(K) Flow(porn) 1 Nater Supply 120000 5.00 72.000 71.000 6.0.R. 32.377 3.51 20.00 190041_SHERIDAN-PLACE RESIDENCE ALL LVLS_FIRE SPRI Water Supply at Node 1 (1200.00.5.00, 72.000, 71.000) 100- 90- 80 tatic Pressure 72.000 70 I '200.00 I 71.&00" 7' ro L @45.89 F25Z.00,vAthhose streams - — - CL 50 30 ystem demand curve - 20- 10- 0 'IIIL'JIIIIL hUh .L)U.UJ.I.I L._A.LJ.IJ_J I.iI.I.U_L.1 II liii I II III I I 2250 2500 1500 1750 2000 M075010001 250 Water flow, gpm M.E.P.CADr Inc. L11 AutoSPRlNK 2019 05.1.14.0 10/31/2019 2:42:57PM Page 1 [ydrauIic_Summary Job Number 190041 Report Description: I HD CALC (1) Job - Job Number Design Ereneer 19-0041 MIGUEL DLT Job Name State CertieoetAriltjcerrea Number SHERIDAN PLACE RESIDENTIAL 684025 Address 1 3913 SHERIDAN PLACE ANJ CARLSBAD FIRE DEPT. Address 2 CARLSBAD, CA 92008 Job Sitetfluldir Address 3 Droning Name 190041_SHERIDAN PLACE RESIDENCE ALL LVLS_FIRE SPRI System Remote Area(s) Meet oennarHing Spoulder Data 0000panoy Job SuttSs 4.9 K-Factor 20.00 at 16.660 1 HD CALC I Hose pdowamoo At Source 5.00 Prsssrue 0.050gpnilft2 Hoes etAppflcation 400.00ft2 (Actual 163.00ft2) Additrenal Hose SApPies Number Of Sprtntders Catcldoted Number Of Nozzles Calcidated Coverago Per Sprinkler Node Flow(gpm) 1 0 400.00ft2 - -. -- -- - Total moss Streams 5.00 System Flow Demand - - Toast HAter Rysubed (InottlorN Hose ydeasnoe) 20.00 25.00 Maeimum Pressure tJrtatanoe fl Loops 0.000 Msoimumveteobyubocs Ground 10.70 between nodes 9 and 102 Masimum Velocey Under Ground 6.74 between nodes 1 and 2 Utauma capsAte of ttdet PAss Votume sspacOy St Sey Flyer 18.929a1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node j Name (gpm) (psi) (psi) (gpm) I (psi) (gpm) . (psi) t (psi) I Water Supply 5.00 J 799 I 71.000 I 1200.00 71.999 .1 2 45.897 26.102 Contractor Corflraotor Number 1 Cereact Name SYMONS FIRE PROTECTION Collect lyle sense OtCoflflactor. SYMONS FIRE PROTECTION Phone 6195886364 Estenloort Address n FAX 12155 PAINE PL 6195886805 Address 2 POWAYr CA 92064 Evmail MDELATORRE@SYMONSFP.COM Address 3 HAS-SOc f, © M.E.P,CAD, Inc. AutoSPRINK 2019 v15.1 .14.0 10/31/2019 2:43:00PM Page 2 ills IHydrauIic Graph Job Number 19004 Report Description: 1 HD CALC 0 Water Supply at Node I too- 80--- Static Pressure 72000 0000 @ 71.000 70- - - _____ _______ _________ 60- U, 0. to 50— 0.00 p45.897 25.00 with hose streams stem demand curve 30— 20- 1IIIlIjjJjJ_j 111111111 111111111 IIIIIlII 111111111 111111111 I 111111 II II I I I .._ p250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow, gpm Hydrath,c Graph Water Supply at Node 1 Static: Ptesstee 72.000 Resiccat. P.- 71.000 @1200.00 Acallabte Prescore at Time 01 Test 71.999 @25.00 St.Lacrad 45.897 @ 20.00 Soccer Deeraric lirtaiceg tare 0050cC at SWce) 45.897 @ 25.00 © M.E.P.CAD, Inc. 18 AutoSPRINK 2019 v15.1 .14.0 10/31/2019 2:43:02PM Page 3 IHydraUIic Graph fl I Job Number: 19-0041 Ortatrt nacrrinfin, I l-lfl ('Al ( (1\ B.O.R. too— go--- 80— Static Pressure 7200 .12 71.000 70— 60- 50 to to a. 40---- .00 32.377 - 25.00 with hose streams 20 5 3tem demand curve to--- 'llIlllllllllllllll 11111111 111111111 111111111 111111111 11111111 0 1150 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow, gpm Hyd,aljic G,ap, B.O.R. Static: PtesSt,e N/A Rn4LMI: P- N/A fla table P,essure at fires of Test N/A 32.377 @ 20.00 Sfalorecertartattrebltae5 He.. ajcolree .t Seercel - - 32.377 @ N/A 5, © M.E.P.CAD, Inc. M AutoSPRINK 2019 v15.1.14.0 10/31/2019 2:43:02PM Page 4 !ISummary Of Oijtflowinq Devices I Job.Number: 19-0041 , © M.E.P.CAD, Inc. AutoSPRINK 2019 05.1.14.0 10/31/2019 2:43:03PM Pages ~jjljNpde Anaiysis Job Number: 19-0041 <eport iescrlpton: 1 -IL) UALU (1) Node Elevation(Foot) Fittings I Pressure(psi) Discharge(gpm) 1 .........................4P 102 . .. _0 S. 45897 29.0j . i6.660 20.00 2 3 -3-0 ........................................35043 34.597 4 .. cp!g(1-9)9:R - 32.377 - I () Inc. AutoSPRINK 2019 v15.1 .14.0 10/31/2019 2:43:04PM Page 6 [Hydraulic Analysis .1 Job Number: 19-0041 Report Description: 1 RD CALC (1) Pipe Type Diameter Flow - - - Velocity HWC Friction Loss Length lPressure Downstream Elevation Discharge K-Factor Pt Pn Fittings 1 Eq. Length Summary Upstream Total Length Routel ..... DR - - - 08740 2000 - 10.70 150 0.209466 I 4-11 Pt 2.278 -- 102 i90 20.00 4 16.660 Sprintier, - 1 6-0Pe-0.217 9 196 18.721 21(3-0) 10-11 Pv FM 0.8740 10.87 . 5.81 150 0.067779 46-11 iPf 3.991 9 19-6 18.721 12-01Pe 4.335 5 9'6 27.047 Tr(1-0), 2E(4'-O), 1(3-0) 58-11 Pv FR 1.1010 20.00 6.74 150 0.068041 10'-2Pf 1.644 5 9-6 9.13 27.047 Flow (q) from Route 2 14-0 1 Pe 3.685 4 11-0 32.377 E(5-0), 2f, 3Tr(1-0), CV(5'-0), 24'-2 Pv cplg(1-0), B4O.R. I BL .........1..Q2_.0_. 7.7 ... ....15...................0.096394 0.482 4 1-0 32.377 .5'OPf iPe 1.739 3 4-0 34.597 5,-U Pv UG 1.5050 20.00 3.61 150 0.014848 30-0 Pt 0.445 3 -3-0 34.597 Pe 2 4-0 35.043 30-0 ipv UG 1.1010 20.00 6.74 150 0.068041 - - - . 3'-OiPf 10.204 2 4-0 - 35.043 - Pe 0.650 1 4-6 45.897 wtviv(-10.000), S 3'0 Pv 5.00 Hose Allowance At Source 1 25.00 =. ..... Route 2 ..... FM 0.8740 9.13 4.88 150 0.049118 58'-5IPf 3.951 9 19-6 - 10.87 18.721 Flow (q) from Route 1 22-0 Pe 4.335 6 9-6 27.007 4Tr(1'-0), E(T-0), 1(3-0), 2E(4'-O 80-5 Pv FR 1.1010 9.13 3.08 150 0.015955 2'-6Pf 0.040 6 9-6 27.007 lPe 5 9-6 27.047 2'-6 Pv lEquivalent Pipe Lengths of Valves and Fittiigs (C=120 only) C Value Multiplier Actual Inside Diameter 487 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiying Factor 0.713 - 116 1.33 1.51 © M.E.P.CAD, Inc. AutoSPRINK 2U9 v15.1 .14.0 1011/7019 2-4 -flRPM =.-= 7 1111 Hydraulic Analysis Job Number: 19-0041 Report Description: 1 HD CALC (1) Pipe Type Diameter Flow - Velocity HWC Friction Loss .Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length ISummary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Fool Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point n a pipe i DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90 Elbow UG Underground Pt Pressure loss due to friction between points EE 45 Elbow Pe Pressure due to elevation difference between indicated Eel 11 Elbow points Ee2 221W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90 FireLock(TM) Elbow fEE 45 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90 Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. J AutoSPRINK 2019 vi 5.1.14.0 10/31/2019 2:43:06PM Page 8 Hydraulic Overview I Job Number: 19-0041 Renort flescriotion 2 HI) (AI r (11 job Job Nurnbor 19-0041 &gn Engtneer MIGUEL DLT Job Name: Fto FAX SHERIDAN PLACE RESIDENTIAL 619-588-6364 619-588-6805 Address I State CoflilcatiotilUcense Number 3913 SHERIDAN PLACE 684025 Address 2 ANti CARLSBAD, CA 92008 Address 3 CARLSBAD FIRE DEPT, JOb Site/6ijld,flg System Oersity Obea OlApptroattofl 0.0509pm/ft' 400.00W (Actual 186.14W) MAX DemaJoing SHunNer Data Nose Streams 4.9 K-Factor 13.00 at 7.039 5.00 Coverage Per Spqi,frgej NumNe,OtSprifltdorsCaNulated torte, aSpreonCstJosd 400.00W 2 0 System pressOme Demand 35.211 System Ftreoerrard 27.13 TeSt Damand 32.13 @35.211 Peessore R- +36788(511%) Supplies Check Point Gauges Node Name Flow(gm) Hose Flow(ppm) Static(psi) Residual(psi) Identifier Pressureipsi) K-Factor(K) Flow(ppm) I Vier Supply 1200.00 5.00 72.000 71.000 B OR. 21.680 0 0.00 B.O.R. ADU 21.339 3.16 14.59 190041 SHERIDAN PLACE RESIDENCE _SLL LVLS_FIRE SPRI Water Supply at Node 1 (1200.00, 5.00, 72.000, 71.000) 100- 90 80- tatic Pressure 72.000 70 @ 71.0O f1200.06 50 a- 60E 3231@ 5.211 hose streams30 20 mand curve 10 jjjjjj; LLLLLLL J.LLLLLl LLLUJJJJ III liii Iii liii 2250 2500 P07501000 1250 1500 1750 2000 Water flow, gpm , © M.E.P.CAD, Inc. UN AutoSPRINK 2019 v15.1.15.0 1121/2020 3:29:20PM Page 1 IHydraulic Summary Job Number 190041 Report Description: 2 HD CALC (1) Job Job Number Design Engireer 19-0041 MIGUEL DLI Job Name: State CertutoaSoru1joerse Number - - - SHERIDAN PLACE RESIDENTIAL 684025 Address 1 3913 SHERIDAN PLACE AlA CARLSBAD FIRE DEPT. Address 2 CAR LSBAD, CA 92008 Job Slreiatulding Address 3 01mAr19 Name 190041_SHERIDAN PLACE RESIDENCE—ALL LVLS_FIRE SPRI System Remote Area(s) Most Dersandeg Spttntder Data 0005Parleo Job NullS 4.9 K-Factor 13.00 at 7.039 2 HD CALC 005. djbwanoe At bsurOe Density keg ototpptication 5.00 0.050gpm/ft9 400.001t2 (Actual 186.14ft) bdd5tonal Nose SuPs Number Of Sprirlders Caloriated sumNer ot NszztasCaloriated Coverage Per SprurMer Node Flow(gpm) 2 0 400.00ft2 buloPeak Results Pressure For Remote Area(s) Adjacent To Most Remote fAda Tetat Hose Streams 5.00 Nystenr Fbm Demand i Total PuNter ReSound (iroindirg Hose Pilowarve) 27.13 3213 ............. 0.000 Maoimunr Se1ect0 Above G- 14.51 between nodes 23 and 24 sraoununrVeotoityUodersre.and I 9.14 between nodes 1 and 2 ttosumeeapaooyofbbott0..-. VI DrOP... 21.66ga1 Supplies . . . . IHose Flow I Static Residual Flow Available Total Demand Required Safety Margin Node I Name (gpm) (psi) (psi) (gpm) (psi) @ (gpm) (psi) (psi) - Water Supply 5.90 J72.000I 71.000 - 1200.00 _71.999 ...32.13 I ?l 36.788 Contractor Csntractsr Nunoter CArdast Name Coldest rule 1 SYMONS FIRE PROTECTION same at Conlracror SYMONS FIRE PROTECTION Ptrorse 6195886364 Addresst 12155 PAINE PL - FAX 6195886805 Address 2 Perot POWAYr CA 92064 MDELATORRE@SYMONSFP.COM Add 3 VJwA.bos Q, ©M.E.P.CADr Inc. AutoSPRlNK 2019 v15.1.15.0 1/21/2020 3:29:23PM Page 2 1111Hydraulic Graph Job Number: 19-0041 Pnn,+ I rinIj,w ) 1-10 ('Al C Ill Water Supply at Node I too- 80 - tatic Pressure 72.000 1612 00.00 71.000 70- 60------- (a 0. 50- 40---- 7.13 35.211 32.13 with hose streams 30- ,stem demand curve 20- to— !lIll_I!! 111111111 111111111 111111111 11111111 111111111 I I I II I II _ °250 500 750 1000 1250 1500 1750 2250 2500 Water flow, gpm Water Supply at Node 1 State. Pressire 72.000 ResidI: P.- 71.000 @1200.00 Ava taN e Pressure at Time er to St 71.999 @32.13 S em Aorta 35.211 @27.13 Sysioaeard(trekertrs tosS PJirre5r. at Soiea) 35.211 @32.13 I— & @ M.E.P.CA Inc. M AutoSPRlNK2019v15.1.15.0 1/21/2020 3:29:24PM Page I§Hydraulic Graph . I Job Number: 19-0041 P,v,rt r-rintnn ) l-l1l ('Al ( (1' B.O.R. ADU 100— go--- 0 :Static Pressure 72.000 _4200.0C@71.000 70- 60----- 0, j 40 30---- 14.59 21.339 20- 19.59 with hose streams item demand curve 10- 0 jULUILL JjiJ.JJ.i_J.J 1111111111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 50 00 750 '000 1250 1500 1750 2000 2250 2500 Water flow, gpm H4Gp B.O.R. ADU Slaic Ft.flt,. N/A Reial P—re N/A AaRaS Piessure LI TIme LI Test N/A 21.339 @ 14.59 Syterri Demesa (memo9 HOe. flHe.rO. Semme) 21.339 @ N/A , © M.E.P.CAD, Inc. M AutoSPRINK 2019 v15.1 .15.0 1/21/2020 3:29:24PM Page 4 IN 1surnrnary ÔfO'tfIowing Devices Job Number: 19-0041 , © M.EPCAD, Inc. jigAutoSPRINK 2019 v15.115.0 1/21/2020 3:29:26PM Page 5 IM[Node Analysis I Job Number: 19-0041 Node Elevation(Foot) Fittings Pressure(psi) <eport I)escrlptlon: 2 HI) UAL (1' Discharge(gpm) 1 .-4'-6 S . 211 27.13 201 . ....... 1.9:9 SP!(: !21) ... 1 8.321 1413 202 9-0 Spr(-7.039) 7.039 13.00 2 10 -3-0 ..1-0.cpIg(i -0) .... 24.202 2122 1 - - 11 9-6 17.015 14 - -3-0 C(8-6) 23.419 J 20 -3-0 23.347 -- 21 1-0 cplg(1'-O) B.O.R. ADU 21.339 I 22 .........!j.4:01_ 16.990 .-j .............. - .1474........- 9.041 .. . ... - .,11 L. ..:3:9L.._............. L............- 23.364 ,(c)M.E.P.GAI) Inc. AutoSPRINK2019v15.1.15.O 1/21/2020 3:29:27PM Page IHydrau1ic Analysis Job Number: 19-0041 n....-.-;.%.;...,,. fl UM /'AI Pipe Type Diameter Flow - Velocity HWC Friction Loss Length 'Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings i Eq. Length Summary Upstream Total Length =. ..... Route l ..... DR 08740 . - 695 0.094407 j 11'-6Pf 2.219 202 9-0 13.00 4.9 7.039 Sprinkler, I 12-01Pe -0.217 24 9'6 9.041 E(4'-O), E(7'-0), Tr(1'-O) 23'6 Pv BL 0.8740 27.13 14.51 150 0.368312 7'-4Pf 5.634 24 9-6 14.13 9.041 Flow (q) from Route 2 8-0 Pe 23 9'6 14.674 E(7'-0), Tr(1'-0) 15'4 Pv BL 0.8740 14.59 7.80 150 0.116871 7'-10lPf 2.315 23 9-6 14.674 Tr(1'-0) 12'-0; Pe 22 9-6 16.990 E(7'-O), E(4'-O) 19-10 Pv FR 1.1010 14.59 4.92 150 0.037963 8'-6Pf 0.664 22 9-6 16.990 9-0 Pe 3.685 21 11-0 21.339 2f, 3Tr(1'-0), CV(5'-O), cplg(1'-O) 17'-6Pv B.O.R. ADU BL 19.0 . 14 5.67 . - 5' -0 0.269 21 1-0 21.339 Pa 1.739 20 -3-0 23.347 5'-0IPv 1.5050 14.59 2.63 150 0.008284 0-0Pf 0.072 20 -3-0 23.347 8'-8IPe 14 4-0 23.419 C(8'-8) 8-8 Pv LJG . ..........273 1.5050 .1. .89 .......JQ.. 0.026108 30'-OPf 0.783 14 -3-0 12.54 23.419 Flow (q) from Route 3 Pe 2 4-0 24.202 30'-0Pv UG - . 1.1010 . 27.13 g.14 .150 . 3'0 Pf 10.359 2 -3-0 24.202 Pe 0.650 1 . 4-6 35.211 wr1v(-10.000), S 3-0 Pv 5.00 Hose Allowance At Source 1 32.13 =...... Route 2 ..... DR 0.8740 14.13 7.56 150 0.110208 . . 1'-61Pf 0.937 201 9-0 14.13 4.9 8.321 Sprinkler, 1 7'-0Pe -0.217 24 9-6 9.041 E(4'-0), 1(3-0) 8'-6IPv =. ..... Route 3 ..... BL . 1.0250 1 54 .......4.88 150 . .0.0710. 5'-0Pf 0.203 10 1-0 21.422 1Pe 1.739 119 -3-0 23.364 5-0 1:Pv 1.5050 -. 12.54 2.26 150 0.006265 0'-0P1 0.054 119 4-0 23.364 8'-8Pe 14 -3-0 23.419 C(8'-8) 8'-8Pv =. ..... Route 4 ..... AO 0.8740 12.54 6.71 150 0.068376 13'-6Pf 2.341 23 9-6 14.674 1(3-0) 13'-0Pe 11 9-6 17.015 2T(3'-0), E(4'-O) 26-6 Pv FM ......Q 14 .. 4.23 150........08707 . 11'-2Pf 0.722 11 9-6 '17.015 14!-0 Pe 3.685 10 11-0 21.422 E(5-0), 2f, 3Tr(1'-O), CV(5'-0), 262Pv cplg(1'-O) Equivalent Pipe Lengths of Valves and Fittings (C=120 only)k C Value Multiplier Actual Inside Diameter 487 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0.713 -1.16 i. .. .1 51 . Is) M.E. F'.CAD, Inc. PjAutoSPRINK 2019 v15.1 .15.0 1/21/2020 3:29:29PM Page 7 j Hydraulic Analysis Job Number: 19-0041 1 Report Description: 2 HD CALC (1) Pipe Type Diameter Flow V!qity ..!Wc Friction Loss - Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length summary Upstream Total Length Pipe Type Legend Units Legind Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90 Elbow UG Underground Pf Pressure loss due to friction between points EE 45 Elbow Pe Pressure due to elevation difference between indicated Eel 11 '/ Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90 FireLock(TM) Elbow fEE 45 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90 Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. PjAutoSPRINK 2019 v15.l .15.0 1/21/2020 3:29:29PM Page 8 Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 May 2019 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. Model RFC76 Model RFC Cover Plate Sprinkler M del Nominal K-Factor gpmlpsi"2 Ø/min/barw). Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS lRA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20x20(6.1 x6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). I WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or Iso 7-1 R1/2 Nominal K-Factor 4.9(71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly. Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector. Bronze Alloy Cup: Steel Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) I Bottom View Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFc49LL Sprinkler Components and Dimensions [_ 2-5/16" (58 mm) Threads r Dia. Body Cup Tower I 1-3/4° (44 mm) +1- 1/4" (6 mm) c U Fusible Link Nominal face of fitting to ceiling Deflector (retracted) J1r3h165mm Pin (extended) V..—.. I& - •__ Deflector (extended) Model RFC Cover Plate _____ 3-5/16" (84 mm) Dia Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure"' Max. Coverage Area Ordinary Temperature Intermediate Temperature Flow Pressure _________________ Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (i/mm) . (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) . (0.48) (49.0) (0.48) 18x18 . 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 IIiIi Page 4 of 8 May 2019 www.reIiablesprinkler.com Cover Plate Finishes(') Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended - I- Min.to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling(' Ceiling Rating inch (mm) inch (mm) RFC30, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 135°F2 RFC43LL, RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 1650F'3 RFC49LL (74°C) 135°F2 RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/410 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protec- tive cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed us- ing the Model FC wrench by temporarily removing the protec- tive cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permit- ted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over thesprinkler until the wrench engag- es the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 141020 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 May 2019 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliabtesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 1 Page 8 of 8 May 2019 am www.reliabIesprinkler.com Z AeIiabI Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model FiRes Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model Fl Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 130. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Residential Sprinkler Summary Bulletin 135 May 2019 Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. ThbleA I Sprinkler Model Sprinkler Identification Orientation K-Factor gpm/psV'2 Thread Size Installation Options Max. Coverage Area Number (SIN) Opm/bar) NPT or 1S07-1 ft x ft (m x m) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30CCP R3511 Pendent 3.0(43) 1/2 Concealed or Conical Recessed 14x 14(4.3x4.3) F1Res49 COP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res58 COP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res76 COP R7618 Pendent 7.6(109) Conical Concealed or 20 x 20(6.1 x 6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) FiRes 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2" NPT or 1507-1 R1/2 Temperature Ratings Nominal K-Factor 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector Bronze Alloy Mel W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions i1u1tY 2-1/4' (57mm) 2-1/4' (57mm) (49m 1-15/16" to finished ceiling 4(49m ceiling Face of fitting DIA. Face of fitting 5/8' (16mm) (49mm) OIA. 1/?(13mm) to finished 3/8" (9mm) +/-1/4'(6mm) OWH 2-1/4 (57) l/4" (44mm) +1- 115/8'(4lmm)+/- 1/4'(6mm) 8" (9mm) L(32mm) 2-7/8" (72mm) DIA. - 1 1-1/4' I 2-7/8" (72mm) DIA.— Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemsm Maximum Coverage Aream ft x ft. (mx m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13(49) 7.0 (0.48) 1104 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0(0.48) 18 x 18(5.5 x 5.5) 17 (64) 12.0(0.83) 20 x 20 (6.1 x 6.1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7(0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0 (1.03) 20x 20(6.1 x 6.1) 22(83) 20.2(l.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 MPORM Page 3 of 15 May 2019 www.reliabIesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinlcler Fl, F2. FV, FP ), CCP, SWC (Conical) Sprinkler ('I Fl, ' FP, CCP, SWC (Conical) Escutcheons Cover Plates Escutcheons Cover Plates V) Bronze Brass - Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester (2) Polyester Polyester (2) Polyester -- Custom Color Custom Color Custom Color Paint - Polyester Polyester Electroless Nickel -- PTFE(2)- Notes: (1) Paint or any other coatng applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, R and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not al F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; fcr installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model GFR2 Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: .1/2" NPT and IS07-1R1/2: 8-18 ft-lbs (11 -24 N-m) 3/4" NPT and 1S07-1R3/4: 14-20 ft-lbs (19 -27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model W2 Bulletin 135 Page 14 of 15 May 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or IS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) 0 Bulletin 135 Page 15 of 15 May 2019 www.reliablesprinkIer.com Bulletin 014 March 2019 R I R Model F1 FR Series - e I a Quick Response ,b.le, Glass Bulb Sprinklers Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model FIFR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model FIFR42, FIFRXLH & FIFR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model FI171142, F1FR40, FIFRXLH & FIFR28 Recessed Sprinkler Types Standard Spray Pendent Model FIFR56LL & FIFR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation tabe in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL1 99. FM Approvals (EM) Loss Prevention Certification Board (LPCB) VdS Schadenverhütung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA 1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/172 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed PendentFl/F2 Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- I ton of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model Fl FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model Fl FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model Fl FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model Fl FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model Fl FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model Fl FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model Fl FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact With the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard;: ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height _____ Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches - mm Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA14131 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA14131 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA14231 cULus 1,2 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 1 57 W2 RA14151 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB I 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. 2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated s p r i n k l e r s o n l y . V d S a p p r o v e d s p r i n - klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable M o d e l C C P c o v e r p l a t e s , available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) o f a d j u s t m e n t . cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Min i m u m t o m a x i m u m d e f l e c t o r t o ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal S i d e w a l l s p r i n k l e r i s f o r L i g h t H a z a r d occupancies only. cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupanci e s o n l y . (°) The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LP C B a p p r o v a l o f t h e F l F R 5 6 V e r t i c a l Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector! Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) Temp. Rating I 175°F (79°C) Temp. Rating I 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb I Yellow Bulb I Given Bulb Blue Bulb Pendent cULus FIFR28 Recessed Pendent cULus -- _________ Upright cULus Pendent VdS Fl FR40 Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus Pendent -- I cULus, ULH I -- FIFR42LL Recessed Pendent -- ( cULus, ULH I -- Pendent cULus F1FRXLH Recessed Pendent cULus -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC cULus cULus,VdS,EC I cULus I Fl FR56 Concealed Pendent* -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- I cULus, ULH I FIFR56LL Recessed Pendent - I cULus, ULH I - Concealed Pendent* -- I cULus, ULH I -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM I -- FIFR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification s p r i n k l e r s u s e a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers u s e a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model Deflector/ (Fig. I & 3) (Fig. I & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB , cULus, VdS, EC RA1414 EC VdS,EC FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS - FIESCUTCHEONJ ADJUSTMENT F2ESCUTHEON 1/2712.7mm] ADJUSTMENT I---------- 1 15/16 D14 - [492mm] - FACE OF F1177NC TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS = 3/879.5mm] f F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] Fl ESCUTCHEON ,AT MAXIMUM RECESS 7/8722.2mm] AT MINIMUM RECESS = 1-5/8741.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8728.6mm] AT MINIMUM RECESS = 1-5/8741.3mm] Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon j-& 2 5/8w D14. [66.7mm] HOLE IN CEILING I 2 5/16 D14. [58.7mm] CUP CEILING - 1 X 1/2 REDUCER FACE OF FiTTiNG TO FACE OF CEILING DIMENSION AT MAX/MUM RECESS = 1-1/2738mm] AT MINIMUM RECESS = 1725.4mm] [12. 7mm] J I AT MAXIMUM RECESS = 9/16714.3mm] Y AT MINIMUM RECESS = 1725.4mm] ADJUSTMENT Ar 3 1/4 014. j t [82.6mm] Model Fl FR56, Fl FR561-L, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF F/fliNG TO FACE OF CEILING DIMENSION F? ESCUTCHEON AT MAX/MUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/89.5mm] F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4 19mm] AT MINIMUM RECESS = 3/89.5mmJ 2 1/4" HOLE 0/A. [5Z2mm] Fl ESCUTCHEON [L4 AT IAA WLII 114 DCC' I at iViflflflWI.fl7 flCI.,J.? - I ,Jf U £ ,_I7. OflflJ AT MINIMUM RECESS = 2- 1/16"[52. 4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] AT MINIMUM RECESS = 2- 1/16"[52.4mm] [3.2mm] "X 1/2" REDUCER I (T' 1 15/16" Dt44jJ4 ..I 4"-12" [701.. 6mm-304.8mm] _i±i! CEILING TO 27132- 014 [72.2mm] DEFLECTOR TURN COLLAR UNTIL liGHT AGAINST SPRINKLER LIP WRENCH BOSS. Fl ESCUTCHEON 1/212. 7mm] ADJUSTMENT alipum RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.404] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 7 x 1/2" REDUCING TEE OR ELBOW EITE :+z::i 25/8"DIA. 2 5/16 DIA - ______ HOLE IN CEILING CUP ,4IJ O3tV 1 1/2" MAX. I115?9JII 1 FACE OF FITTING ""L Ill I!! T]I TO FACE OF CEILING J '" t1t Ill DIMENSION CEILING 1/2" MAX. I ,7' 15/16" COVER ADJUSTMENT COVER PLATE - ASSEMBLY 35716 DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT 0I7FGO1A Fig. 4 Model Fl FR56iF1 FR56LL Concealed Pendent sprinkler with standard depth 1/24nch (12.7mm) adjustment - Model CCP cover plate 91 I" x 1/2" REDUCING TEE OR ELBOW 2 5/16" DIA - CUP ---- CEILING 5/16" MAX. COVER ADJUSTMENT COVER PLATE— DIA. ASSEMBLY 3 5116 SPRINKLER - 2 5/8" DIA. HOLE IN CEILING 1 1/2' MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" CONCEALED, 5/16" ADJUSTMENT oiivco Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent spunkIer with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plate' Bronze Brass I Chrome Chrome Plated Chrome Plated I White Polyester Coated 14 White Painted I Special Application Finishes Sprinkler Escutcheon Cover plate" Electroless Nickel PTFE'7 Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Pai020> Black Paint I Off White Off White2>6 Off White I Satin Chrome Chrome Dull I Chrome Dull I (I) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. 11) cULus Usted only. 's> 200°F (93°C) maximum. (41 cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. ' FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. ( LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. 171cULus; listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load ScrewPint1e: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28] [Fl FR40] [Fl FR42] [Fl FR42LL][F1 FRXLH][ Fl FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [1350F (570C)1[155°F (68°C)][ 175°F (790C)][200°F (930C)][286°F (1410C)] Sprinkler Finish Escutcheon Model: [F1][F2][FPJ Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some o f t h e m a n y precision-made Reliable products that guard life and property from fire arou n d t h e c l o c k . Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the late s t p u b l i s h e d S t a n d a r d s o f t h e National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by - Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices (j Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in USA. 03/19 Pfi'.J 9999970300