3266 GREY HAWK CT; ; FA060033; Permit
10/31/24, 10:01 AM FA060033 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA060033 3266 GREY HAWK Job Address: Status: ISSUED CT Permit Type: FALARM Applied 6/8/2006 Parcel No: 2210150200 Approved: 6/8/2006 Lot #: 0 Reference No.: Issued: 6/8/2006 PC #: Inspector: Project Title: GREY HAWK BUSINESS CTR FIRE ALARM INSPECTIONS Applicant: JMG SECURITY 17150 NEWHOPE SUITE 109 800-900-4564 EXT.31 6 Owner: GREYHAWK ASSOCIATES C/O RUDY BALDONI 949 S COAST DR #600 COSTA MESA CA P Fees ($) FAdfflFees($) Total ($)i Balance ($) 60 0 60 I 0 about:blank 1/1 Fire Alarm System Record of Completion Name of Protected Property: Greyhawk Business Park, Lot 5 Building "T-U-V" Lam f =A66o6 33 Address: 3262. 3264 &3266 Greyhawk Court, Carslbad, CA. 92009. Representative of Protected Property. (name/ telephone): Authority Having Jurisdiction: CARLSBAD SAFETY CENTER Address/Phone Number: 2560 Orion Way, Carslbad, CA. 92010. tel 760) 931-2141. 1. Types of System or Service NFPA 72, Chapter 3 Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3 Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telepho'ne jacks included in system: NFPA 72 Chapter 4 Auxiliary Indicate type of connection: Local energy: Shunt: Parallel telephone: Location and telephone number for receipt of signals: Q NFPA 72 Chapter 4 Remote Station Alarm: Supervisory: NFPA 72, Chapter 4 Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number Of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 4- Central Station The Prime Contractor: DBA National Monitoring Center (NMC). Central Station Location: 26800 Laguna Hills Drive, Suite 250. Aliso Viejo, CA. 92656 Means of transmission of signals from the protected premises to the central station: Digital alarm communicator Means of transmission of alarms to the public fire service communications center: Central Station Operators telephone call System location: 26800 Laguna Hills Drive, Suite 250. Aliso Viejo, CA. 92656 Organization Name Representative Name Telephone Installer JMG SECURITY SYSTEMS Mike Trenblay 714-545-8882 Supplier JMG SECURITY SYSTEMS Mike Trenbtay 714-545-8882 Service Organization JMG SECURITY SYSTEMS Mike Trenblay 714-545-8882 Location of Record (As-Built) Drawings: At Premises Location of Owners Manuals: At Premises Location of Test Reports: At Premises A contract dated '? / , for test and inspection in accordance with NFPA standard(s) No(s) NFPA 72, dated 1999, is in effect. 2 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as listed below, was inspected by ___on I I - ' C-' , includes the devices listed below and has been in service since li—I O F?! NFPA 72, Chapters ® () () ® ® 6 (!) (circle all that apply) I?! NFPA 70, National Electrical Code, Article 760 I?! Manufacturer's Instructions Other (specify): Signed: Date:________________________________ Organization: 3. Record of System Operation All operational features and functions of this system were tested by_f7 Al on I"- t -06 , and found to be operating properly in accordance with the requirements of F?! NFPA 72, Chapters ® () © () 6 (Z) (circle all that apply) I?! NFPA 70, National Electrical Code, Article 760 F?! Manufacturer's Instructions 0 Other (specify): Signed: Date:_________________________________ Organization:_____________________________________________ 4. Alarm-Initiating Devices and Circuits (use blanks to indicate quantity of devices) MANUAL 1 Manual Station 0 Non-coded i:i Coded, Activating 1 Transmitters - Combination Manual Fire Alarm and Guard's Tour Coded Stations. AUTOMATIC Coverage: Minimum Code Required LSmoke Detector 0 Ion 0 Photo - Duct Detector 0 Ion 0 Photo Heat Detector 0 FT 0 RR 0 FTiRR RC I Sprinkler Waterfiow Switch 0 Noncoded 0 Coded, Activating 2 Transmitter - other (list): 5. Supervisory Signal Initiating Devices and Circuits (use blanks to indicate quantity of devices.) GUARD'S TOUR N/A Coded Stations N/A Non-coded Stations, Activating Transmitters (C) NIA... Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM - Coded Valve Supervisory Signaling Attachments 3 Valve Supervisory Switch, Activating 2 Transmitter El Building Temperature Points El Site Water Temperature Points Q Site Water Supply Level Points ELECTRIC FIRE PUMP JJ_. Fire Pump Power El Fire Pump Running U Phase Reversal ENGINE-DRIVEN FIRE PUMP Selector in Auto Position Engine or Control Panel Trouble (/) Fire Pump running ENGINE-DRIVEN GENERATOR (k) Selector in Auto Position (I) U Control Panel Trouble El Transfer Switches U Engine Running Other Supervisory function(s) (specify): 6. ALARM NOTIFICATION APPLIANCES AND CIRCUITS Quantity of indicating appliances connected to the systems: 1 Types and quantities of alarm indicating appliances installed: _Bell 10 Inch _Speakers 1 Horns - Chimes - Other: 0 Visual Signals Type::STROBE []with audible w/o audible (g) 1 Local Annunciator 7. SIGNALING LINE CIRCUITS Quantity and Style (see NFPA 72, Table 3-6) of signaling line circuits connected to a system: Quantity: 1 Style: 4 3 8. SYSTEM POWER SUPPLIES (a) Primary (Main): Nominal Voltage: 120 VAC Current Rating: 20 AMPS Overcurrent Protection: Type: BREAKER I I Current Rating: 20 AMPS Location: AT MAIN ELECTRICAL BREAKER PANEL (b) Secondary (Standby): Storage Battery Amp-Hour Rating: 7 A !..._ Calculated capacity to drive system, in hours Z 24 Hrs. 0 60 Hrs. N/A Engine-driven generator dedicated to fire alarm systems Location of fuel storage: N/A (c) Emergency or Stand-by System used as a backup to Primary Power Supply, instead of using a Secondary Power Supply: N/A Emergency System described in NFPA 70, Article 700 N/A Legally Required Standby System described in NFPA 70, Article 701 N/A Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. SYSTEM SOFTWARE Operating System Software Revision Level(s) NIA Application Software Revision Level(s) N/A Revision Completed by: N/A 10. COMMENTS: (signed) for the Central Station or Alarm Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s) System deviations from the referenced NFPA standard(s) are: NONE (4 j V VC11L 1 - '- (signed) for pentral Stati4r,4larrpfiervice Company 0 (title) (date) 4 (signed) Representative of Autholty having Jurisdiction ' (title)