Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2830 WHIPTAIL LOOP; ; FPC2023-0040; Permit
City of PERMIT REPORT Carlsbad Print Date: 09/10/2024 Permit No: FPC2023-0040 Job Address: 2830 WHIPTAIL LOOP, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: 2091202900 Track #: Applied: 02/28/2023 Valuation: $0.00 Lot #: Issued: 11/07/2023 Occupancy Group: Project #: Finaled Close Out: 09/10/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Valdes, Rebecca Plan Check #: Salcedo, Felix Maldonado, Adalmira Cheung, Nathaniel Project Title: Description: IONIS LOTS 21 & 22 -INSTALL UNDERGROUND FIRE LOOP FDCS/PIV'S/HYDRANTS/BACKFLOWS (5 HYDRANTS) FEE AMOUNT FIRE Hourly Services (first hour) FIRE Hourly Services (first hour) FIRE Hourly Services (first hour) FIRE Hourly Services (first hour) FIRE Hourly Services (first hour) FIRE Plan Resub (3rd&Subsequent Submittal/hr) FIRE Underground Piping with 5+ Hyds/Risers $207.00 $207.00 $200.00 $200.00 $200.00 $170.00 $2,360.00 Total Fees: $3,544.00 Total Payments To Date: $3,544.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov RECEIVED FEB4 zd3 CAL BAD FIRE DFME FPC2023-0040 IONIS LOTS 21,1122 - INSTALL UNDERGROUND FIRE r rn it A p p I I cat I 0 LOOP FDC'S/Pl\IS/HYDRANTS/BACIçFLOWS (5 HYDRANTS) Project Information ionis Lots 21 and 22 Project Name Whiptail Loop (APN 209-120-23,24) Project Address Suite # Scope of Work Installation of underground fire loop, FDCs, PIVs, hydrants, backf lows Associated Building Permit U (if applicable) (V> t4) LI Fire Sprinkler System: Number of risers Underground: Number of Hydrants 5 LI Fire Alarm LI Sprinkler Monitoring LI New System LI Tenant Improvement LI Other: IM ioZL.Do49 Number of Heads 2091202300 2/28/2023 FPC2023-0040 Engineer —Contractor Information PLSA Company Name Address 119 Aberdeen Drive Applicant Name Jacob Wittier Phone 619-259-8212 ext 107 Cardiff City CA 92007 State Zip Email jwittier@plsaengineering.com Contractor License Number and Type Exp. Date City Business License Number Signature Date For questions about the application submittal package please email: Fire Permit Technician Fire Prevention 1 1635 Faraday Ave I Carlsbad, CA 92008 1 442-339-2660 1 www.carlsbadfire.org No. 294 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: lonis Shell SR#: (Assigned upon plan submittal) PROJECT ADDRESS: Whiptail Loop @ Gazelle Court CITY: Carlsbad PHONE: (858) 259-8212 (iwittler@plsaengineering.com) FAX NUMBER: Largest Building (ft 2) 164 Sprinkled? Construction Type: Il-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Whiptail Loop @ Gazelle Court TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 130 PSI Hydrant Number (if applicable):H61672 Elevation of test: 400 Feet Main Size: 16 INCH Pressure Zone: 700 Feet Date/Time of Test: Pitot Tube Reading: PS Corresponding Flow: GPM Total Flow: 8,000 GPM Residual Pressure 105 PSI At peak demand , this water system is capable of providing afire flow discharge at 20 psi in excess of 8,000 gpm. Based on the square footage and construction type provided, the maximum fire flow required is 8,000 gpm for 4 hours before any reduction is applied for sprinklers. Note that the City uses the bottom of the tank as the zone grade line for determining static pressures. Therefore, it is entirelylikelythatlowerflowscouldresultinpressuresabovethebaselinestaticpressure. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: _- Title/Org: P_ie_Mana Date: 11/28/2022 / W?PTAIL LOOP Fire Flow Test /1 I 47, . 80 8C \\ all IN CA 1130 \ I / \ \\ \ \ Legend ________ - - * w Hydrant ZONE —550 700 + #294 lonis Shell -Fire Flow Analysis - .4 USTEI 66? IFTE1) Straight Single Clapper Two—Way Inlets Exposed auxiliary inlet connection CERTIFICATIONS with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying APPROVED CE x 1191 LISTED 166Y Fire Dept. inlet requirements. Standard equipment: Cast brass two-way inlet body with single swing clapper and pin ______ or rocker lug hose thread swivel; a b straight NPT outlet connection. Branding: "AUTO SPKR" 4"x2-112" L_.._.._.t 5-33/64" T B J 8-5/64" I SPECIFY THREAD 900 Single Clapper Two-Way Inlets A >or SPECIFY THREAD Exposed auxiliary inlet connection with CERTIFICATIONS 00 G.P.M. inlet capacity to supplement fire protection U1 Water supply. Exposed design rpovides an economical CE x 1191 LISTED 166Y thod of satisfying Fire Dept. nlet requirements. tandard equipment: Fast brass two-way inlet body with single swing clapper fl b and pin or rocker lug hose thread swivel; 4" 2-1/2- angle NPT outlet connection. Branding: "AUTO SPKR" 4"x2-112"I A 8-5/64" B [6-11/16" I. T"' { 4-29/3 "-4"x2 1/2 2—WAY SIAMESE FDC 18"-24" 4" SWING CHECK OR WAFER CHECK VALVE FINISHED GRADE >)2 6" DUCTILE IRON PIPE (PER NFPA-13 2002ed. SECTIONS 10.1.2 & 10.1.3) DETAIL FIRE DEPARTMENT CONNECTION N.T.S. A UL Liste FM Appro AWWA AMERICAN Flow Control Submittal Information 4" - 12" SERIES 2500-1 RESILIENT WEDGE GATE VALVE, NRS SK20041101-1 SHOWN WITH 2" OPERATING NUT SHOWN WITH OPTIONAL HANDHWEEL F TYTON® (TY) OPTIONAL END CONNECTIONS DIMENSION YALIZ!_ EndtoEnd - MJIMJ 10.00 10.50 11.50 12.50 13.50 EndtoEnd - FIJFL 9.00 10.50 11.50 13.00 14.00 EndtoEnd - TY/TY 13.00 15.88 17.50 18.75 19.75 End to End - FLIMJ 9.50 10.50 12.38 13.62 14.38 End to End - FLTY 11.00 13.19 14.50 15.88 16.88 EndtoEnd - PVC/ PVC 1300 1588 1750 A 13.91 17.12 20.47 24.06 27.59 B 2.50 2.50 2.50 2.50 2.50 C 4.00 5.22 5.50 - - D 4.00 5.22 5.50 5.62 5.62 E 9.00 11.19 1 13.50 15.88 18.00 F DIA 1.00 1.00 1.00 1.31 1.31 Handwheel Diameter 10.00 12.00 14.00 15.50 15.50 No. of Turns to Open 14 20 26 1 32 38 FLOW CONTROL THE RIGHT WAY AMERICAN Flow Control Waterous Company P.O. Box 2727 125 Hardman Avenue South Birmingham, Al. 35202-2727 South St. Paul, Mn. 55075-1191 Phone: 1-800-326-8051 Phone: 1-888-266-3686 Fax: 1-800-610-3569 Fax: 1-800-601-2809 E-mail: atcsales@amencan-usa.com E-mail: afcsates@american-usa.com WWW.AMERICAN-USA.COM -4 / PC '' MECHANICAL JOINT (MJ) PVC (NOT AVAILABLE FOR UL/FM) Page lof 2 GV11055 Issued: 1/9/2012 29 17 STANDARD 2 OPERATING NUT 2 3 6 OPTIONAL HANOWHEEL 65 12 49 65 5 40 8 13 - 14 69 10 11 REF DESCRIPTION NO. MATERIAL 1 Hex Head Bolt, 5/8-11 x 1" 304 Stainless Steel 2 Operating Nut, Ductile Iron, ASTM A536 2" Square 3 0-Ring Rubber 5 Stuffing Box Gasket Rubber O-ring 6 Hex Head Bolt, 5/8-11 x 304 Stainless Steel 1-3/4" 7 Stuffing Box Ductile Iron, ASTM A536 8 Bonnet Ductile Iron, ASTM A536 10 Bonnet Gasket Rubber 11 Body Ductile Iron, ASTM A536 12 Stem Manganese Bronze, ASTM B763, UNS C86700 13 Wedge Nut Manganese Bronze, ASTM B763, UNS C86700 14 Resilient Wedge EPDM Rubber Encapsulated Ductile Iron ASTM A536 15 Hex Nut, 5/8-11 304 Stainless Steel 17 Handwheel Ductile Iron, ASTM A536 19 Hex Head Bolt, 5/8-11 x 304 Stainless Steel 2-1/4" 29 Flat Washer, 5/8 304 Stainless Steel 40 ULIFM Label Pressure Sensitive Acrylic Film 49 0-Ring Rubber 65 Thrust Washer 304 Stainless Steel 69 Wedge Cover Acetal Polymer OPTIONAL MATERIALS ARE AS FOLLOWS BOLTS and NUTS: 316 Stainless Steel STEM: Cast NDZ-S Bronze, ASTM B763, UNS C99500 STEM: Stainless Steel WEDGE NUT: Silicon Bronze, ASTM B584, UNS C87600 Open Direction: Left (C.C.W.) Right (C.W.) NOTES: Available in configurations that are UL Listed and FM Approved with 250 psig rated working pressure. Meets requirements of ANSI/AWl/VA C515 with 250 psig rated working pressure. Fusion-bonded epoxy-coated in accordance with ANSI/AWWA C550. Certified to ANSI/NSF Standard 61. PL52506-1 A1CAPIN Construction shown is typical of the 6-inch size with mechanical joint end con- FLOW CONTROL nections and is illustrative only. Construction of other sizes and end connection types vary slightly. See elsewhere on this submittal for specific details. THE RIGHT WAY AMERICAN Flow Control Walerous Company P.O. Box 2727 125 Hardman Avenue South Birmingham, Al. 35202-2727 South St. Paul, Mn. 55075-1191 Phone: 1-800-326-8051 Phone: 1-888-266-3686 Fax: 1-800-610-3569 Fax: 1-800-601-2809 E-mail: afcsalesamencan-usa.com E-mail: afcsales@amencan-usa.com RNW.AMERlCAN-USA.COM Page 2of2 GV11055 Issued: 1/9/2012 tltJfl Ut3KIVIUUI'I maltklA& railS NVlflfltk iJ. rut NO. BODY BRONZE I 2 STEM SLEEVE BRONZE F1630001 1 -- 3 STEM BRONZE F1630806 1 4 OUTLET BRONZE F1630003 1 5 CARRIER BRONZE P1630811 6 RETAINER NUT BRONZE F1630808 7 VALVE RUBBER I URETHANE T1530013 I 1 11 _0-RING(OUTLET) RUNA-N 11630276 1 13 0-RING (STEM) BUNA-N T1630269 2 14 0-RING (STEM SLEEVE) BUNA-N - 11630278 1 15 j PRO CAP GASKET C.1- RUBBER T1630176 1 16 PRO CAP PLASTIC 11630161 17 STEM NUT BRONZE P1630809 1 18 - LOCK PIN COPPER 11630062 1 2000 SERIES DIMENSIONS 29 t 26 Eq : 2 QDEL 21518" 2Z? /4 H, -111 14i/8" , L - II 1/4 lI 1/4 20/2' rV 2010 MODEL 13 I4j5 I MODEL JJLH 2dII/4" Traditional Engineering Excellence Over 100 Years Fire hydrants are a key element of a municipality's fire protection system. They must be reliable, easy to maintain and aesthetically pleasing to the community. Municipalities have depended on CLOW to meet these requirements for over 130 years. Advanced Technology The Clow Series 2000 The CLOW Series 2000 couples all bronze construction with a working water pressure of 200 psi. Hydrostatically shall tested up to 600 psi. Exceptional Performance Series 2000 Features Hydrant rated to withstand 200 psi working water pressure and fully hydrostatically tested to 400 psi. Valve assemblies can be interchanged with parts can be removed from outlet port side for easy maintenance and repairs. The 2000 Series low profile is namufactured with a geometric silhouette design which compliments the architecture of the most modern and progressive community. High strength all bronze body casting conforming AWWA C503 Standard. Removal of bronze outlets offer flexibility of field repairs without disassembling the hydrant head from the bury section. Threaded-in outlets with a bubble tight "0" ring make for quick, easy field repairs (without removing the hydrant head from the bury section). Heavy duty operating stems meet or exceed AWWA torque requirements. Light weight hydrant reducing handling and maintenance costs. Furnished with heavy duty plastic caps in all size pentagons, 11/8', 11/2', and 13/4', equipped with chains. (Bronze caps optional). Valve rubbers made from urethane rubber which is abrasion and nick resistant. Hydrant can be drilled to all size hole drillings, 6H, 6HSD, and 8H standards. Soecificotions All Bronze Wet Barrel Hydrants The wet barrel hydrant head shall be made of bronze meeting AWWA C503 Standard. It shall be capable of withstanding a hydrostatic test pressure of four times the working water without stressing the material beyond its yield point per Section 3.2.3.2 of AWW C503. Wet barrel fire hydrants shall feature independently valved parts. The working parts shall be engineered to function as a unit and to give trouble-free service over long periods of time. Hydrants shall be designed for working pressure of 200 psi. The design factor of safety of hydrant valves shall be 5 based on ft/lb torque required for the closing and opening of individual valves at 200 psi working pressure hydrant capable of being opened or closed after being subjected to and opening torque of 200 ft-lbs. applied at the operating system. Length of Bury The bury shall be specified to the nearest six inches measured from face of the hydrant flange to the center of the connecting pipe. The hydrant body shall be so designed that it may be removed by unbolt- ing from the bury section above the ground line. When specified by the purchaser, the bolts provided shall have tensile strength less than the shear force required to break the hydrant body. Marking All hydrants shall be permanently marked to identify the series number of the hydrant, the manufacturer, country and the year in which the hydrant was manufactured. Testing Hydrants shall be subjected to a hydrostatic pressure of 400 psi with the whole interior of the hydrant under pressure. Hydrant valves shall be fully opened and closed to insure full operation. Hose Threads Hose and pumper nozzle threads shall be in conformity with "National Standard Fire Hose Coupling Screw Threads", ASA Fi-26, unless otherwise specified. Protector Caps Protector caps shall be ABS plastic to meet ASTM D1788, Type 2, Grade 1. They shall be securely chained to the hydrant barrel and furnished (with or without) an inner gasket. Standard nut size of the valve stem and protector caps shall be of pentagonal shape and furnished with a nut of 1 1/8" measured from point to flat of the pentagon. Nut sizes measuring 1 1/2" and 1 3/4" also furnished. Bronze protector caps can be furnished when specified by the purchaser. Painting Exterior of hydrant shall receive a primer coat and will be furnished with a traffic yellow enamel finish coat unless otherwise specified. A suitable clear sealer in lieu of primer/paint may be used if specified by the purchaser per Section 4.2.2.2 of AWWA C503. Material Specifications Bronze Casting: ASTM B-62 Valve Facings: Individual valves of hydrant shall be a urethane polyether base compound and cured to a shore durometer hardness of 90; tensile strength of 2700 psi; approved by FDA for use with potable water. Bolts and Nuts: Bolts for joining the body to the bury section shall conform to ASTM A307, Grade B. Stem Packing: An "0" ring seal of proper design shall be used. "0" rings shall be compounded to meet ASTM D2000 and have physical properties suitable for the application. Hydrant Designation Model 2010-6 x 2-1/2 x 4/6 IPS Model 2050- 6 x 2-1/2 x 4/4 Model 2060-6 x 2-1/2 x 2-1/2 x 4/4-1/2 > Model 2065- 6 x 2-1/2 x 4/4-1/2 x 4/4-1/2 Job Name - Contractor Job Location Approval Engineer Contractor's P.O. No. Approval - Representative Colt TM Series LFC300 (LFColt 300), LFC300N (LFColt 300N) Double Check Detector Assemblies Sizes: 21/211 - 10" The Colttm LFC300, LFC300N Double Check Detector Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water sup- ply system.The Colt LFC300, LFC300N may be installed under continuous pressure service and may be subjected to backpres- sure. The Colt LFC300, LFC300N is used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. For use in non-health hazard applications. Features Extremely compact design 70% Lighter than traditional designs 304 (Schedule 40) Stainless Steel housing & sleeve Groove fittings allow integral pipeline adjustment Patented tn-link check provides lowest pressure loss Unmatched ease of serviceability - 'Available with grooved butterfly valve shutoffs May be used for horizontal, vertical or N Pattern installations Replaceable check disc rubber Specifications The Colt LFC300, LFC300N Double Check Detector Assemblies shall consist of two independent Tr-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tr-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tr-Link Checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. The bypass assembly shall consist of a meter, which registers in either gallon or cubic measurement, a double check valve assem- bly and required test cocks. Assembly shall be a Colt LFC300, LFC300N as manufactured by the Ames Fire & Waterworks. ** Metric Dimensions are nominal pipe diameter. This product is produced with ASME/ANSI flanged end connections. (LFColt 300GV) The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FIRE t3CWATERWORKS A WATIS Brand Ames Are & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Are & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. I-------------------- H ...........................I C-------------------- Configurations Available Models Horizontal Vertical up "N' pattern horizontal Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna N Tr-Link Checks: Noryl®, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Lead Free* Bronze Body Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Dimensions - Weights open) F--------------------------- A-------------------------- LFC300, LFC300N Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection *Q5 GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Pressure - Temperature Temperature Range: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 1 75ps1 (12.06 bar) SIZE DIMENSIONS WEIGHT in A in. mm C (OSY) in. mm D in. mm G in. mm H in. mm I in. mm J in. mm in. P mm LFC300 lbs. kgs. LFC300N tbs. kgs. 2½ 30/4 781 163/a 416 31/2 89 29V16 738 211/2 546 151/2 393 813/16 223 133A6 335 139 63 147 67 3 313/4 806 l8/8 479 3W16 94 301/4 768 22¼ 565 171/8 435 93A6 233 141h 368 159 72 172 78 _4_ 333/4 857 223/4 578 4 102 33 838 231/2 597 181/2 470 915A6 252 153A6 386 175 79 198 90 _6_ 43½ 1105 30½ 765 5½ 140 44% 1137 33¼ 845 23Yi6 589 13A6 332 19 483 309 140 350 159 849'/4..J264 37%. 959.. '/16 170 54¼ 13T5. 40½ _tQ19 276 .J9L 15 1A6 399. 21%s.... 538 j 494224 569 258 10 1 573/4 1467 1 453/4 1162 1 8,46 208 1 66 1676 .491/2 1257 1 321/2 1 826 1 l75A6440,. 24 610. 795 361 1 965 438 LFC300BFG, LFC300NBFG DIMENSIONS WEIGHT in. A in. mm C in. mm D in. mm G in. mm H in. mm I in. mm J in. mm P in. mm LFC3008FG lbs. kgs. LF300NBF lbs. kgs. 21h 27/4 705 8 203 3½ 89 297/8 759 211/2 546 1415A6 379 8'M 223 13 330 70 32 78 35 3 281/4 718 8/16 211 3A6 94 3011A6 179 221/4 565 157A6 392 91/16 233 131h 343 68 31 81 37 4 29 737 8W16 227 311A6 94 31W16 811 23½ 597 16¼ 412 915A6 252 14 356 75 34 98 44 6 361h 927 10 254 5 127 433A6 1097 33¼ 845 1911A6 500 131A6 332 141h 368 131 59 171 78 8 42/4 1086 121/4 311 61h 165 511A6 1297 401/a 1019 235A6 592 151A6 399 183A 462 275 125 351 159 Noryl® is a registered trademark of SABIC Innovative Plastics". ** Metric Dimensions are nominal pipe diameter. This product is produced with ASME/ANSI flanged end connections. Approvals Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The Unversity of Southern California (FCCCHR-USC) AWWA C510-97 For additional approval information please contact the factory or visit our website at www.amesfirewater.com ** SSIp1 ** (9 CP ~FM@ C us C®US Approved 1048 B64.5 (BFG & OSY Only) Horizontal - N-Pattern -----Z-Pattem 2½" PSI Service Flow Rated Flow *UL Rated Flow 14 - - - - —' N 12 - - - - - ---TiJ 10 OW I 0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 1pm 7.5 15 fps Capacity ULJFM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. is Rated Flow identifies maximum continuous duty performance determined by AWWA. UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than l0fps. 6" PSI Service Flow Rated Flow *UL Rated How 12 N 10 _____ _____ ____ U, a 6 o C 4 0 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 1pm 7.5 12 fps 3,' )SI Service Flow Rated Flow *UL Rated Flow 12 10 6 4 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 1pm 7.5 15 fps 4,, psi service mow RatedIaI,' ii CO C 24 20 16 12 4 0 _____-__ _____-__________ ~~ffl M~ :: - - -________ 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 1pm 0 7.5 13 fps at 4 psi 12 10 6 0 Service Row Rated Flow *UL Rated Flow 8" — — - - N 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 1pm 0 7.5 10 fps 10" Service flow Rated flew lit Rated How N -I H V 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 1pm 7.5 10 fps N N V H Psi 12 10 e 6 4 0 11111WITIM94111111111 Inquire with governing authorities for local installation requirements ILA LMNA AM E5 FIRE & WATERWORKS A WAITS Brand USA: Backilow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves 1: (713) 943-0688 • F: (713) 944-9445 • AmesFireWatercom Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 55-4122-0138 • AmesFireWater.com ES-A-LFC300/LFC300N 2005 © 2019 Watts VAI FINISHED GRADE DETAIL POST INDICATOR VALVE N.T.S. H - No. and Sue o Slots Equally 0 J - Bolt Circle 2 MJ Ends wrench nut as required ( Q - No. and Size of Hole Slots Equally Spaced on OR - Bolt Circle 2 FL Ends toe NO. DESCRIPTION B. Ott. MATERIAL *310 NOTES I COOSF?OTo I otuslolnloostoel FEES croupa.cw 2 W!en0T?Tqur l Duolpc TOt *536 1AO?i.TTOIIO,,00,flO, 0 *00101 S Born,? 1 0*0510 TNt *556 0 SenT I B?0nu0 5 l•• Net. IS eOttet OTt9 I NiTriC 6*60,? OS 532 IT ENoVMJ End, I duOlIleiTon *506 IS 030 0031*0 T 0*0110 Iron usd6 1,593 IS Donna? (1*5 IrS olBotonleo STool FEEd GT0up2.CW Rubber Encapsulated Ductile Iron Disc Ductile Iron ASTM A536 Rubber Options 1,536 .ASTM 02000 2.EPDM- ASTM D2002 Bronze Stem Orson,: 1*305 onese.AsTMDl3e Alloy C67600 2.Everdur - ASTM 038 Alloy C66100 SECTION A-A -TYPICAL MECH JOINT ENDS -MJ x MJ FLANGE ENDS - FL x FL APPROVED .. - ------- -- --- - ---- -I eerAflH€WSU0EBeT SO?37e,c.Aop29,2058) ECO#218272 - c 1 f rJ I to I urns to weight OR Weight Open Mio0*J 0 P 0 laoS cdo all FLcPu ITIFEE 'HE PART OW RECEPI-S —SE 2361 RWGV 350W W/ Ply SBX erie ow. NO Rev DI 7414 A SCALE: WEIGHT (lbo): SEE TABLE SHEET lOP 1 ![SUT1 FIELD ADJUSTMENT INSTRUCTIONS TELESCOPING BARREL 2945A TRENCH DEPTH LIMITS Valve Size Mm. Max. Mm. Max. Mm. Max. Mm. Max. IPARTSLIST DET P-i OTY 1 13361270 PART NO. DESCRIPTION LOCKING WRENCH MATERIAL CAST IRON ASTM A126 CLASS B P-2 1 3024872 OPERATING NUT BRONZE ASTM (4-14") 8584 ALLOY 864 P-3 1 442639P RETAINER 0-RING BUNAN 226 P-4 1 3020912 TOP SECTION CASTIRON ASTM A126 CLASS B P-5 2 441980P WINDOW GLASS LEXAN-UV STABILIZED P-6 2 443370P OPEN TARGET CAST ALUMINUM P-i 2 443371P SHUTTARGET CAST ALUMINUM P-8 1 - TARGET CARRIER ASSEMBLY P-8A 1 3005802 TARGETCARRIER BRONZEASTM (4-12") NUT B584 ALLOY 864 P-8B 2 443347P TARGET CARRIER 1/16" SHEET PLATE METAL P-8C 4 440736P CLAMPTARGET 16.GA302SS RETAINER P-8D 8 444171P #10-24X1/2" PAN ZINC PLATED HEAD STEEL P-8E 4 442411P #10-24 HEX NUT ZINC PLATED STEEL P-B 11 443476P 1/2" NPT PIPE PLUG MALL IRON P-10 1 440254P 3/8" EYEBOLT #23 FORGED STEEL P-11A 1 444303P 3/8-i 6X1" HEX ZINC PLATED CAPSCREW (ADJ. STEEL POST) P-12 1 ** STEM 1" SQUARE AISI M1020 HRS P-13 1 318035& CRANE COUPLING CAST IRON ASTM A126 CLASS B P-14 1 442190P COTTER PIN BRASS P-15 2 444342P 3/4" HEX HEAD ZINC PLATED SCREW STEEL P-16 1 3004774 TELESCOPING 5" D.I. Class 52 BARREL ANSI A21.51 P-li 1 ** LOWER STANDPIPE 4" DI Class 52 (ADJ. POST) ANSI A21.51 P-lB 1 3180402 BASEFLANGE CAST IRON (3-12") ASTM A126 CLASS B P-lB 3 444355P 5/8"Xl" HEX HEAD ZINC PLATED SCREW STEEL P-20 4 444357P 5/8"X2 1/4" HEX ZINC PLATED CAPSCREW STEEL P-21 4 442484P 5/8" HEX NUT ZINC PLATED _____ STEEL Updated 4/4/2014 idIiiavtsisii I