Loading...
HomeMy WebLinkAbout3125 LIONSHEAD AVE; ; FPC2024-0073; PermitI1:i IJIi1.]F4I Cr'city of Carlsbad Print Date: 09/23/2024 Job Address: 3125 LIONSHEAD AyE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2218801800 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2024-0073 Status: Closed - Finaled Applied: 05/21/2024 Issued: 08/14/2024 Finaled Close Out: 09/23/2024 Final Inspection: INSPECTOR: Robinson, Jarrod Salcedo, Felix Project Title: Description: UPS -INSTALL SPRINKLER SYSTEM IN NEW CONVEYOR BANDS (704 HEADS) (E-REVIIEW) (REV. 1: REVISED PER FIELD INSTALL CONDITIONS. REV 1 SUBMITTED DIGITALLY, ORG IS HARD COPIES) Applicant: FPContractor: HILLER COMPANIES THE HILLER COMPANIES LLC BRIEN PISKE 140 GRAND ST, # STE 300 7130 CONVOY CT WHITE PLAINS, NY 10601-4840 SAN DIEGO, CA 92111-1019 (251) 661-1275 (858) 277-3473 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $823.00 FIRE Plan Review (per hr - Regular Office Hours) $170.00 Total Fees: $993.00 Total Payments To Date: $993.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov CARLSBAD RACEWAY 3125 Lionshed Ave Carlsbad, CA 92008 Product Data Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. 1. FIRE SPRINKLERS 14 tqC00 Worldwide I Contacts www.tyco-fire.com Series TYB and TYFRB Poly-Stainless Sprinklers IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp682 General Description The TYCO Series TY-B and TY-FRB Poly-Stainless Sprinklers are corrosion resistant sprinklers designed for use in commercial occupancies where corro- sive atmospheres may exist. The series characteristics are as follows: TV-B Series 5 mm diameter heat sensitive glass bulb Standard response (SR) rating TY-FRB Series 3 mm diameter heat sensitive glass bulb Quick response (QR) rating Although corrosion resistant sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of this coating material for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity, should be consid- ered, at a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. Upright and Pendent Sprinklers The upright and pendent sprinklers are standard coverage spray sprinklers available in either 5.6 or 8.0 K-factor. The recessed version is intended for use in areas with a finished ceiling. The two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) recessed escutcheons provide 1/2 inch (12,7 mm) of recessed adjustment or 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the recessed escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Horizontal Sidewall Sprinklers The horizontal sidewall sprinklers are designed for installation along a wall or side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of upright and pendent sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. A recessed version of the horizon- tal sidewall sprinkler can be achieved by using the Style 10 recessed escutcheon. NOTICE The Series TY-B and TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TV-B Standard Response 1Y3151 ... Upright 5.6K, 1/2 in. NPT TY3251 . . . Pendent 5.6K, 1/2 in. NPT TY4151 ... Upright 8.0K, 3/4 in. NPT TY4251 . . . Pendent 8.0K, 3/4 in. NPT TY3351 .....HSW* 5.6K, 1/2 in. NPT TY-FRB Quick Response TY3131 ... Upright 5.6K, 1/2 in. NPT TY3231 . . . Pendent 5.6K, 1/2 in. NPT TY4131 ... Upright 8.0K, 3/4 in. NPT TY4231 . . . Pendent 8.0K, 3/4 in. NPT TY3331 .....HSW* 5.6K, 1/2 in. NPT = Horizontal Sidewall Page 1 of 10 AUGUST 2022 TFP682 TFP682 Page 2 of 10 Model K-Factor Response Type Temperature RatingColor Bulb Liquid Sprinkler Material Brass TV-B 5.6 1/2 in. NPT SR Upright TY3151 and Pendent TY3251 _______________ 135°F (57°C) Orange 1,2,3 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve Recessed* Pendent TY3251 See Figure 1 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue TV-B 8.0 3/4 in. NPT SR Upright TY4151 and Pendent TY4251 _______________ 135°F (57°C) Orange 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve Recessed— Pendent TY4251 See Figure 1 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue NOTES: ULLlsted C-UI. Listed EAC Approved * Installed with Style 10 (1/2 NPT) Recessed Escutcheon Installed with Style 40 (3/4 NPT) Recessed Escutcheon TABLE A POLY-STAINLESS SERIES TV-B STANDARD RESPONSE 5.6 AND 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS Technical Data Approvals UL and C-UL Listed EAC Approved Note: For complete approvals information, see Tables A, B, and C. Maximum Working Pressure 175 psi (12,1 bar) Temperature Rating See Tables A, B, C, and D Physical Characteristics Frame ..............Polyester coated Brass Button ................L316 Stainless Steel* Compression Screw .....L316 Stainless Steel' Bulb...............................Glass Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON° Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. "Beryllium Nickel (UNS N03360) Gold Plated per MIL 0-45204, Type 3, Class 2. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B and TY-FRB Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency - for example, the UL Listing is based on the requirements of NFPA 13. Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed installation. TFP682 Page 3 of 10 Model K-Factor Response Type Temperature Rating Bulb Liquid Color Sprinkler Material Brass TY-FRB 5.6 1/2 in. NPT QR Upright TY3131 and Pendent TY3231 135°F (57°C) Orange 1,2,3 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent. TY3231 See Figure 2 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue TV- FR B 8.0 3/4 in. NPT OR Upright TY4131 and Pendent TY4231 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent** TY4231 See Figure 4 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) Blue NOTES: UL Listed C-UL Listed EAC Approved * Installed with Style 10(1/2 NPT) Recessed Escutcheon ** Installed with Style 40 (3/4 NPT) Recessed Escutcheon TABLE POLY-STAINLESS SERIES TY-FRB QUICK RESPONSE 5.6 AND 8.0 K-FACTOR UPRIGHTAND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP6B2 Page 4 of 10 Model K-Factor Type RatinResponse Temperature Bulb Liquid Color Sprinkler Material Brass TY-B 5.6 1/2 in. NPT SR Horizontal Sidewall TY3351 135°F (57°C) Orange 1, 2, 3 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve _______________ Recessed Horizontal Sidewall* 1Y3351 See Figure 5 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue TY-FRB 5.6 1/2 in. NPT QR Horizontal Sidewall TY3331 135°F (57°C) Orange 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Horizontal Sidewall* TY3331 See Figure 6 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green 286°F (141°C) Blue NOTES: UL Listed C- UL Listed EAC Approved * Installed with Style 10(1/2 NPT( Recessed Escutcheon TABLE C POLY-STAINLESS SERIES TY-B STANDARD RESPONSE AND POLY-STAINLESS SERIES TY-FRB QUICK RESPONSE 5.6 K-FACTOR HORIZONTAL SIDEWALL SPRINKLERS LABORATORY LISTINGS AND APPROVALS 2-7/8 (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION 7/16' (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6 mm) UPRIGHT 2-3/16" (55,6 mm) (38,1 mm) STYLE 10 RECESSED ESCUTCHEON 2-7/8' (73,0 mm) DIA. RECESSED PENDENT PENDENT 2-7/8" (73,0 mm) DIA. TFP6B2 Page 5 of 10 WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. UPRIGHT 7/16 1,1 mm) OMINAL 2-3/16 4AKE-IN (55,6 mm) J(525 mm) (38,11 STYLE 10 RECESSED PENDENT ESCUTCHEON FIGURE 1 POLY-STAINLESS SERIES TV-B STANDARD RESPONSE UPRIGHT (TY3151) AND PENDENT (TY3251) 5.6 K-FACTOR 1/2 INCH NPT SPRINKLERS WRENCH 1/2 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. thu.' CROSS SECTION FIGURE 2 POLY-STAINLESS SERIES TV-FRB QUICK RESPONSE UPRIGHT (TY3131) AND PENDENT (TY3231) 5.6 K-FACTOR 1/2 INCH NPT SPRINKLERS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. UPRIGHT 1/2 (12,7 mm) i NOMINAL MAKE-IN 2-5/16" _F (58,7 mm) 16" (57,2 mm) (39,7mm) STYLE 40 RECESSED PENDENT ESCUTCHEON RECESSED PENDENT Iti11 CROSS SECTION FIGURE 3 POLY-STAINLESS SERIES TV-B STANDARD RESPONSE UPRIGHT (7Y4151) AND PENDENT (TY4251) 8.0 K-FACTOR 314 INCH NPT SPRINKLERS 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFP682 Page 6 of 10 WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. UPRIGHT 1/2" (12,7 mm) NOMINAL MAKE-IN 2-5/16 I I 1 (58,7 mm) 1-9/16 I (57,2 mm) (39,7 mm) STYLE 40 RECESSED PENDENT ESCUTCHEON FIGURE 4 POLY-STAINLESS SERIES TY-FRB QUICK RESPONSE UPRIGHT (TY4131) AND PENDENT (TY4231) 8.0K-FACTOR 3/4 INCH NPT SPRINKLERS DEFLECTOR 1 - Frame 2 - Button HAT 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw / 6 - Deflector* 6* 9/16 WRENCH 1/2' (14,3 mm) FLATS NPT 1-13/16" 7/16" 46,0 mm) ______ (11,1 mm)_ CENTERLINE NOMINAL I OF SPRINKLER MAKE-IN WATERWAY 1-1/2" (38,1 mm) ESCUTCHEON PLATE SEATING ______ 2-3/16 SURFACE (556 mm) STYLE 10 RECESSED f ESCUTCHEON *Temperature rating is indicated on Deflector 2-7/8" DIA (73,0 mm) [}_. FIGURE 5 POLY-STAINLESS SERIES TY-B STANDARD RESPONSE HORIZONTAL SIDEWALL (TY3351) 5.6 K-FACTOR 112 INCH NPT SPRINKLERS Installation The TYCO Series TY-B and TY-FRB sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 ft-lbs (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 10 to 20 ft-lbs (13,4 to26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the sprinkler by under- or over-tightening the sprin- kler. Re-adjust the position of the sprin- kler fitting to suit. *Temperature rating is indicated on Deflector 2-7/8" (73,0 mm) FIGURE 6 POLY-STAINLESS SERIES TY-FRB QUICK RESPONSE HORIZONTAL SIDEWALL (TY3331) 5.6 K-FACTOR 1/2 INCH NPT SPRINKLERS TFP682 Page 7 of 10 Upright and Pendent Sprinklers The Poly-Stainless Series TV-B and TY-FRB Upright and Pendent Sprin- klers must be installed in accordance with the following instructions: Step 1A. Upright sprinklers must be installed in the upright position, and pendent sprinklers are to be installed in the pendent position. Step 2A. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3A. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, refer to Figure 10. With reference to Figures 1,2,3, and 4, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Recessed Pendent Sprinklers The Poly-Stainless Series TV-B and TV-FRB Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step lB. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe sealant applied to the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step 213. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, refer to Figure 11. With reference to Figures 1, 2, 3, and 4 apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step 3B. After the ceiling has been installed or the finish coat has been applied, slide the Style 10 or 40 Closure over the sprinkler and push the Closure over the Mounting Plate until it comes in contact with the ceiling mounting surface. Horizontal Sidewall Sprinklers The Poly-Stainless Series TV-B and TY-FRB Horizontal Sprinklers must be installed in accordance with the follow- ing instructions: Step 1C. Horizontal sprinklers must be positioned in the horizontal position with their centerline of waterway per- pendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2C. With pipe thread sealant applied to the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step 3C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, as shown in Figure 10. Apply the W-Type 6 Sprinkler Wrench to the wrench flats shown in Figure 5 and Figure 6. 1 - Frame DEFLECT( HAT 2 - Button 3 - Sealing Assembly 4-Bulb 5 - Compression Screw 6 - Deflector* 9/16° (14,3 mm) CENTERLINE OF SPRINKLER WATERWAY Recessed Horizontal Sidewall Sprinklers The Poly-Stainless Series TV-B and TY-FRB Recessed Horizontal Sidewall Sprinklers must be installed in accor- dance with the following instructions: Step 1E. Recessed horizontal sidewall sprinklers are to be positioned in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2E. After installing the Style 10 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step 3E. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, refer to Figure 11. Apply the W-Type 7 Sprinkler Wrench to the wrench flats shown in Figure 5 and Figure 6. Step 4E. After the wall has been installed or the finish coat has been applied, slide the Style 10 Closure over the sprinkler and push the Closure over the Mounting Plate until it comes in contact with the wall mounting surface. WRENCH 1/2" FLATS NPT 7/16" I (11,1 mm)_ I NOMINALI - MAKE-IN 1-1/2" (38,1 mm) ESCUTCHEON PLATE SEATING • 2-3/16' SURFACE (55,6 mm) STYLE 10 RECESSED ESCUTCHEON TFP682 Page 8 of 10 2-7/8 DIA. 5/8±1/4 (73,0 mm) - 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4 DIA. 1/4° (6,4 mm) FACE OF MOUNTING SPRINKLER (57,2 mm) M PLATE //# FITTING 1/8° I - (3,2 mm) J MOUNTING SURFACE 7 CLOSURE 3231 or 1-1/4(31,8 mm) f 1Y3251 3/4" (19,1 mm) FIGURE 7 POLY-STAINLESS SERIES TY-B OR TY-FRB RECESSED PENDENT 5.6 K-FACTOR 1/2 INCH NPT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON - 5/8±1/4 (15,9±6,4 mm) MOUNTING FACE OF SPRINKLER SURFACE FITTING CLOSURE 2-7/8° DIA. TY3331 or DIA. I I1 3,0 mm) mm) MOUNTING I TY3351 (57,2 PLATE 1/8 I (3,2 mm) 1-1/4(31,8mm) 3/4°(19,1 mm) 3/4" (19,1 mm) 1/4° (6,4 mm) FIGURE 9 POLY-STAINLESS SERIES TV-B OR TY-FRB RECESSED HORIZONTAL SIDEWALL 5.6 K-FACTOR 1/2 INCH NPT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2-7/8° DIA. 5/8±1/4" - (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER r' L_- PLATE FITTING I i- (3,2 mm)' \ MOUNTING / SURFACE / CLOSURE 1Y4231 or 1-5/16" (33,3 mm) TY4251 13/16" (20,6 mm) FIGURE 8 POLY-STAINLESS SERIES TV-B OR TY-FRB RECESSED PENDENT 8.0 K-FACTOR 3/4 INCH NPT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4° NPT MODELS) FIGURE 10 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 11 W-TYPE 7 SPRINKLER WRENCH TFP6S2 Page 9 of 10 Care and Maintenance P/N 57 - XXX - Standard Response (SR) SIN 570 TY-B 5.6K Upright SR 1V3151 590 TV-B 8.0K Upright SR TV4151 571 TV-B 5.6K Pendent SR TV3251 591 TY-B 80K Pendent SR TY4251 578 TV-B 5.6K HSW SR 7V3351 Quick Response (OR) SIN 370 TV-FRB 5.6K Upright OR TY3131 390 TV-FRB 8.0K Upright OR TY4131 371 TV-FRB 5.6K Pendent OR TY3231 391 TV-FRB 8.0K Pendent QR TV4231 378 TV-FRB 5.6K HSW OR TV3331 The TYCO Series TY-B and TY-FRB Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent oper- ation may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more informa- tion, seethe Installation section. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the integrity of the corrosion resistant material of construction. Thereafter, annual inspections accord- ing to NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprin- kler condition and the long term integ- rity of the corrosion resistant material of construction, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. J_I Temperature Rating 135 135°F(57°C) 155 155°F(68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) 360 360-F (182-C)' * TY-B - Only Sprinkler Finish Grey Aluminium (RAL9007) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies Specify: (specify SIN), (specify Stan- dard Response or Quick Response), (specify K-factor), (specify) tempera- ture rating, (specify Upright, Pendent or HSW), P/N (specify from Table D) Recessed Escutcheon Specify: Style (specify 10 or 40) Recessed Escutcheon, Grey Aluminum (RAL9007) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Recessed Sprinkler Wrench, P/N 56-850-4-001 TABLED POLY-STAINLESS SERIES TV-B AND TV-FRB UPRIGHT, PENDENT AND HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION TFP682 Page 10 of 10 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 C 2022 Johnson Controls. All sights reserved. All specIficatIons and other Information shown were current soot document revision date and are subject to change without notice. Johnson I' NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are regIstered t,udanarrhs ulNutiosul FIre P,otshtlunflsseclutlon; Controls TEFLON Is utrudon,u,h of The Chereosra Company FC, LLC LI Victaulic® FireLockTM Installation-ReadyTM Rigid Couplings \%taulicr Style 009N and Style 109 10.64 .I . Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes Style 009N: 11/4 - 12/DN32 - DN300 Style 109: 11/4 - 4°/DN32 - DN100 Pipe Material Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic For exceptions reference section 6.0 Notifications Maximum Working Pressure Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) to 365 psi/2517 kPa Function Joins carbon steel pipe with grooved ends conforming to publication 25.01 Provides a rigid pipe joint designed to restrict axial or angular movement 2.0 CERTIFICATION/LISTINGS USTED LIPS 1219 Iooue 3.1 EN 10311 Cert/LPCB Ref. 104-la/36 Regulation (EU) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic company. All rights reserved. 1 ictaul.c 2. PIPE & FITTINGS victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange coating Red coating (standard for EMEA-1 and Asia Pacific) Optional for Style 009N: Hot Dipped Galvanized per ASTM A123 Optional for Style 109: Mechanically Galvanized per ASTM B695 (available only in North America and Latin America). Gasket: (specify choice) 0 Grade "E" EPDM (Type A) Vic-PIusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES Reference should always be made to publication 1-100, victaulic Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) Standard: Carbon steel oval neck track bolt(s) meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' 1 Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish. 10.64 07072 Rev R Updated 10/2021 © 2021 victaulic Company. All rights reserved. victaulic.com 2 \JtauIic victaulic.com 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling Size Maximum Maximum Allow. - Bolt/Nut Dimensions Weight Actual Pre-assembled Joint Assembled Outside Working End Pipe End Approx. X V X V Nominal Diameter Pressure2 Load2 Separation3 Qty. Size Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DIN mm kPa N mm - mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 2 3/8 X2 3.13 .5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 2.54 Ml0x51 79 127 70 127 151 0.6 11/2 1.900 365 1035 0.10 Isx 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 2 - M10x51 86 130 76 130 51 0.7 2 2.375 365 1617 012 2 3/8 X2½ 400 563 350 563 200 19 DN50 60.3 2517 7193 3.05 - M10x63 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 2 3/8 X2½ 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 M10x63 114 156 102 156 51 1.0 3.000 .365 .2580 0.12 /ø<2½ 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 2 - M10x63 118 152 105 156 51 1.0. 3 3.500 365 3512 0.12 2 3/Bx2½ 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 M10x63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 3/8X2½ 6.00 7.88 5.63 7.50 2.13 2.9 DN100 . 114.3 2517 25822 4.32 - M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 2 3/8 X2½ 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 - M10x63 152 1.87 137 187 54 1.4 5 5563 365 8872 017 2 ½x3 725 925 675 913 225 50 141.3 2517 39456 4.32 - M12x76 184 235 171 232 57 2.3 5.250 365 7901 0.17 2 1/2 X3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 - M12x76 168 229 162 229 1 57 2.2 5.500 365 8672 0.17 . 2 ½x3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 .38529 4.32 M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 - 2 ½x3¼ 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 44469 4.32 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 ½x3¼ 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 - M12x83 200 254 187 . 251 57 25 6.500 365 12112 0.17 ½x3¼ 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 - M12x83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 5/sX4 10.88 .13.38 10.25 1313 2.50 11.4 DN200 219.1 2517 94863 4.32 2 - M16x 101 276 340 260 333 64 5.2 - 8.500 365 20712 0.17 2 51ax4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 M16x 101 270 337 260 257 67 5.2 10 10.750 300 27229. 0.25 . 7/a x6½ 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 2 M22 165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 7/8 X6½ 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.4 2 - M22 165 406 483 394 486 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the 'EZ' marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation- Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 \/tauIic victaulic.com 4.1 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Style 109 Pre-Assembled Style 109 Joint Assembled Size Max. Max. Allow. Pipe Bolt/Nut Dimensions Weight Actual Pre-Assembled Assembled Outside Working End End Sep. Approx. YL YB X Z YL YB X Z Nominal Diameter Pressure Load Maximum Qty. Size (Each) inches inches psi Lbs. inches inches inches inches inches inches inches inches inches inches lb DN mm kPa N mm mm mm mm mm mm mm mm mm mm kg 1 1/4 1.660 365 790 0.10 3/a X21/4 1.97 2.49 3.17 1.95 1.93 2.59 2.84 1.95 1.5 DN32 42.4 2517 1 3514 2.54 1 M10x57 50 63 81 50 49 66 72 50 1 0.7 11/2 1.900 365 1035 0.10 3,x2'/4 2.13 2.60 3.41 1.95 2.1 2.68 3.07 1.95 1.6 DN40 48.3 2517 4603 2.54 1 M10x57 54 66 87 50 53 68 78 50 0.7 2 2.375 365 1617 0.12 1 3/8 X21,'4 2.32 2.85 3.76 1.98 2.29 2.95 3.45 1.98 1.9 DN50 60.3 2517 7192 3.048 1 M10x57 59 1 72 96 1 50 58 1 75 88 50 0.9 21/2 2.875 365 2370 0.12 %x2¼ 2.63 3.09 4.29 1.99 2.61 3.15 3.93 1.99 2.1 73.0 2517 10540 3.048 1 M10x57 67 78 109 51 66 80 100 51 1.0 3.000 365 2580 0.12 1 7/isx2~ 2.68 3.22 4.56 2.03 2.64 3.45 4.22 2.03 2.4 0N65 76.1 2517 11476 3.048 M11 x69 68 82 116 52 67 88 107 52 1.1 3 3.500 365 3512 0.12 7/J6x234 2.93 3.53 5.13 2.07 2.89 3.78 4.67 2.07 2.7 DN80 88.9 2517 15620 3.048 1 M11 x69 74 90 130 53 73 96 119 53 1.2 4 4.500 300 1 4771 0.17 7A6X2 3/4 3.47 4.01 6.03 2.08 3.43 4.22 5.56 2.08 3.5 DN100 114.3 2068 1 21223 4.318 1 1 M11 x69 88 102 153 53 87 107 141 53 1.6 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the 'EZ" marking on the inside face or No. 60 end caps containing the QV EZ' marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade 'E' Type A gaskets. These gaskets include an integral pipe stop that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation-Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 'jtauIic victaulic.com 5.0 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch. 40 Sch. 10 Sch. 40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 365 365 363 363 363 363 DN32 2517 2517 2503 2503 2500 2500 • 25 25 25 25 25 25 365 365 363 363 363 363 00 DN40 48.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 363 363 2 2375 DN5O 603 2517 2517 2503 2503 2500 2500 • 25 25 25 25 25 25 365 365 363 363 - 363 21/2 2.875 2517 2517 2503 2503 - 2500 o 25 25 25 25 - 25 365 7 - 3638 - 363 363 DN65 3.000 2517 7 - 25038 - 2500 2500 6.1 25 7 - 258 - 25 25 3 3.500 365 365 363 363 363 363 DN80 2517 2517 2503 2503 2500 2500 • 25 25 25 25 25 25 - - 363 363 - - 4.250 + - - 2503 2503 - - - - 25 25 - - 365 365 363 363 363 363 4 DN100 4.500 114.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 3638 - 5.80 133.0 2503 5. 8 25' 290' - 3638 - 232 363 DN125 2000' - 25038 - 1600 2500 35 • 20' - 258 - 16 25 290 365 363 363 232 363 5.563 141.3 2000 2517 2503 2503 1600 2500 25 25 25 16 25 • 60 159 25038 6.500 29010 - 3638 - - 363 165.1 2000 0 25038 - - 2500 2010 - 258 - - 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40 F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required, cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 10220 4.0 mm pipe wall. 1 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 FM approved for 0.188 pipe wall. 11 cULus listed for 0.188 pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 _ictaullill _________ victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch. 40 Sch. 10 Sch. 40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON mm bar bar bar bar bar bar 300 365 300 363 232 363 6.625 2068 2517 2068 2503 1600 2500 DN150 1683 20 25 20 25 16 25 290 - 3638 - - 8.515 2000 25038 = 216.3 20 : 25 1 1 300 365 30012 363 232 363 8 8.625 2068 2517 206812 2503 1600 2500 DN oo 20 25 2012 25 16 25 30013 300 30012 300 - - 10 10.750 206813 2068 206812 2068 - - DN250 273.0 . 2013 20 2012 - - 30013 20 12 300 25012 12.750 2068" 2068 172012 2068 - - DN300 323.9 2013 1 20 1 1712 20 - - 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required, cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. 8 FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 102204.0mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. " With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of "316 on the end face of the bolt. 12 FM approved for 0.188" pipe wall. 13 cULus listed for 0.188" pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 6 \,htauIjc° victaulic.com 5.1 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals'5 The information provided below is based on the latest listing and approval data at the time of publication. Listings! Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Sch. 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 365 365 365 365 232 363 2517. 2517 2517 2517 1600 2503 DN32 25 25 25 25 16 25 365 365 365 365 232 363 1 1/2 1.900 DN40 48.3 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 365 365. 365 365 232 363 2 2.375 2517 2517 2517 2517 1600 2503 DN50 60.3 25 25 . 25 . 25 . 16 . 25 365 365 365 365 - - 21/2 2517 2.875 73.0 2517 2517 2517 - - 25 25 25 25 - - 365 365 365 365 232 363 3000 DN65 76.1 2517 2517 2517 2517 . 1600 2503 • . . . 25 . 25 .25 . 25 16 25 365 365 365 365 232 363 3 3.500 DN80 889 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 300 . 365 300 300 - 290 4 4.500 DN100 1143 2068 2517 . 2068 . 2068 - 2000 20 25 20 20 - 20 15 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems .400 F/C and above. Please see the Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. 10.64 07072 Rev R Updated 10/2021 02021 Victaulic Company. All rights reserved. victaulic.com 7 \JtauIic victaulic.com 5.2 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM psi psi inches kPa kPa Pipe Type DN bar bar lh/4_4 300 EF DN32—DN100 2068 N/A 20 300 300 EL 2068 2068 DN32—DN50 20 20 ET40 2068 N/A DN32 -50 20 300 EZF 3-4 2068 N/A DN80—DN100 20 300 300 EZT 1 1/4-2 2068 2068 DN32—DN50 20 20 300 FF 2068 N/A DN40—DN100 20 300 300 GL 1 1/4-2 2068 2068 DN32-0N50 20 20 300 300 2068 2068 DN32—DN100 20 20 MF 175 175 1205 1205 DN150 12 12 - 300 300 MT 2068 2068 0N32—DN50 20 20 300 MILT N/A 2068 0N32—DN50 20 300 TF 21/2-4 N/A 2068 73.0 rnm—DN100 20 175 300 WGS, WGSE, WFS, WG7, WG7E, WL7 1205 2068 DN32— ioo 12 20 300 300 WLS 2068 2068 DN32—DN50 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZF = EZ-Flow steeli pipe manufactured by Northwest Pipe Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MILT steel pipe manufactured by Wheatland Tube Co TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFIow 5 steel pipe manufactured by Wuppermann Stahl GmbH. WG7, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH WLS = WLS steel pipe manufactured by Wheatland Tube Co. I 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 8 ________ victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM inches psi psi Pipe Type DN bar bar 300 1¼-2'/2 N/A 2068 DN32 —73.0mm 20 300 EF 1 1/2-21/2 2068 N/A DN40 —73.0mm 20 300 300 34 2068 2068 DN80—DN100 20 20 300 1¼-2 N/A 2068 DN32 - DN50 Easy-Flow 20 34 N/A 300 2068 DN80—DN100 20 300 EL 11/4 -2 N/A 2068 DN32 - DNSO 20 300 300 ET4O 1'/4-2 2068 2068 0N32 - DN50 20 20 300 1¼-2 N/A 2068 DN32 - DN50 20 EZT _____________________________ 300 1 ½-2 2068 N/A DN40 - DN50 20 300 300 FF 11/2-4 2068 2068 DN40—DN100 20 20 300 GL 1¼-2 N/A 2068 DN32—DN50 300 300 IMF 2068 2068 DN32 DN32—DN100 20 20 300 300 MT 1¼-2 2068 2068 bN32 - DN50 20 20 300 300 MLT P/4-2 2068 2068 DN32 - DNSO 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru, EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FF = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = CL steel pipe manufactured by Wheatland Tube Co. MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT = MILT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. p 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 9 iictaulliitX u1,I iii,. ran. 5.3 PERFORMANCE (CONTINUED) Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM inches psi psi kPa kPa Pipe Type DN bar bar 300 TF 2½ 4 N/A 2068 73.00 mm—DN100 20 300 1¼-2 N/A 2068 DN32 - 0N50 20 W67,WG7E 34 N/A 300 2068 DN80—DN100 20 300 WLS 11/4-2 N/A 2068 DN32—DN50 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FF = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. MF = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 10 \J'(ctauIic victaulic.com 6.0 NOTIFICATIONS TtIl[ei1 Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. NOTICE Victaulic does not recommend the use of any furnace butt-welded pipe with sizes 2"/DN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 0501: Seal Selection Guide 2501 Original Groove System (OGS) Groove Specifications 1-009N: Installation Instructions FireLock EZTM Rigid Coupling Style 009N 1-100: Victaulic Field Installation Handbook 1-109: Installation Instructions FireLockTM One-Bolt Rigid Coupling Style 109 l-ENDCAP Victaulic End Caps Installation Instructions I-IMPACT Impact Tool Usage Guidelines AN-001: Application Notification - Potential Incompatibility of Type F Pipe, Sizes NPS 2 I DN50 and Smaller User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination auto the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our websile at www.victaulic.com, Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 11 \4tauIic Victaulic® Grooved End Fittings Ai -C- t -au I -ic 07.01 No. 20 Tee No. 10 Elbow 1.0 PRODUCT DESCRIPTION Available Sizes 3/4 - 60/DN20 - DN1500 Maximum Working Pressure .. Pressure ratings for Victaulic standard fittings conform to the ratings of Victaulic Style 177N couplings (refer to publication 06.24 for more information). Application Connects pipe, provides change in direction and adapts sizes or components Supplied with Victaulic OGS grooves Exclusively for use with Victaulic couplings, valves, accessories and pipe which feature ends formed with the Victaulic OGS groove profile Pipe Materials Carbon steel or stainless steel NOTE These fittings are not intended for use with Victaulic plain end couplings. Intended for use only in grooved piping systems. When connecting wafer or lug type butterfly valves direc:ly to Victaulic fittings using Style 741 or Style 743 flange adapters, be sure to check disc clearance dimensions with I.D. dimension of fitting. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 07.01 1449 Rev AFt Updated 07/2022 © 2022 Victaulic Company. All rights reserved. 1 jtiuIicr victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Other Fitting Styles AGS - Advanced Groove System from 14— 60/DN350 - DN1500 Ductile Iron for AWWA size pipe Publication 20.05 Publication 23.05 Stainless Steel Publication 17.16 XL fittings for abrasive services Publication 07.07 Galvanized Publication 07.01 for Original Groove Fittings Publication 20.05 for AGS Fittings Aluminum Publication 21.03 Extra Heavy EndSeal ES" Publication 07.03 Shouldered Ends Publication 07.06 Copper Publication 22.04 Plain End Publication 14.04 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2 A C -ta U -1i C victaulic.com 2.0 CERTIFICATION/LISTINGS UK Fvdjs CR EN 10311 BS EN 10311 CPR (EU) No. 305/2011 CPR (UK) 2019 No. 465 NOTES When supplied as "hot dip galvanized" the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold +86"F/+30"C potable water service and ANSI/NSF 372: No. 10 90" Elbow, No. 1145" Elbow, No. 12 22½" Elbow, No. 13 111/4" Elbow, No. 100 90" Long Radius Elbow, No. 110 45" Long Radius Elbow, No. 20 Tee, No. 25 Tee with Grooved Branch, No. 3045" Lateral, No. 60 Cap, No. 50 Concentric Reducers, No. 51 Eccentric Reducers. The following Victaulic fittings are VdS approved: No.10 90" Elbow, No.11 45" Elbow, No.20 Tee and No.60 Cap. The following Victaulic fittings are LPCB approved: No.10 90" Elbow, No.11 45" Elbow, No.12 22½ Elbow, No.13 11¼" Elbow, No.30 45" Lateral, No.30-13 Reducing Lateral, No.100 Long Radius Elbow, No.110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. The following Victaulic fittings are FM approved: No.10 90" Elbow, No.11 45" Elbow, No.12 22½ Elbow, No.13 11¼" Elbow, No.30 45" Lateral, No.100 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee and No.50 Concentric Reducer. 3.0 SPECIFICATIONS - MATERIAL Fitting: (specify choice) El Standard: Ductile iron conforming to ASTM A536, Grade 65-45-12. Optional: Segmentally welded steel as shown under nipples Nipples: (specify choice) 3/4 - 47DN20 - DN100: Carbon steel, Schedule 40, conforming to ASTM A53, Type F 5 - 6/DN125 - DN150: Carbon steel, Schedule 40, conforming to ASTM A53, Type E or 5, Gr. B 8 - 127DN200 - DN300: Carbon steel, Schedule 30 or 40, conforming to ASTM A53, Type E or S, Gr. B Flanged Adapter Nipples: (specify choice) Class 125 Flange: Cast iron conforming to ANSI B16.1 Class 150 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face El Class 300 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face Fitting Coating: (specify choice) El Standard: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications Flanged Adapter Nipple Coating: (specify choice) C] Standard: None (Unfinished) 0 Optional: Orange enamel, hot dip galvanized and others 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 3 X.A-C-t:a-ulicr victaulic.com 4.0 DIMENSIONS Elbows No. 10 900 Elbow No. 1145* Elbow No. 12 221/20 Elbow No. 13 111/4' Elbow No. 100 900 Long Radius Elbow No. 110 450 Long Radius Elbow C to E Cto tE <( L~-( I, •I .- C to E CtoE Cto Ct Tf 7 I Standard and GSNK No. 100 No. 110 No. 10 No. 11 No. 12 No. 13 900 Long Radius 45° Long Radius Size 90" Elbow 45" Elbow 22V2* Elbow 11 ¼° Elbow Elbow Elbow Actual Approx. Approx. Approx. Approx. Approx. Approx. Outside Wgt. Wgt. Wgt. Wgt. Wgt. Wgt. Nominal Diameter C to E (Each) C to E (Each) C to E (Each) C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb inches lb inches lb inches lb DN mm mm kg I mm kg I mm kg I mm kg I mm kg mm kg 3/4 1.050 2.25 0.5 1.50 0.5 1.63 (sw) 1.38 (sw) 2.50 (sw) 0.4 1.88 (sw) 0.3 DN20 26.9 57 0.2 38 0.2 41 - 35 - 64 0.2 48 0.1 1 1.315 2.25 0.6 1.75 0.6 3.251 0.6 1.38 (sw) 0.3 2.88 (sw) 0.6 2.25 (sw) 0.5 DN25 33.7 57 0.3 44 0.3 83 0.3 35 0.1 73 0.3 57 0.2 11/4 1.660 2.75 1.0 1.75 0.9 1.75 0.8 1.38 (sw) 0.5 3.25 (sw) 1.1 2.38 (sw) 0.7 DN32 424 70 05 44 04 44 04 35 02 83 05 1 60 03 1 1/2 1.900 2.75 1.2 1.75 0.9 1.75 0.8 1.38 (sw) 0.5 3.63 (sw) 2.2 2.50 (sw) 1.3 DN40 48.3 70 0.5 44 0.4 1 44 0.4 1 35 0.2 1 92 1.0 64 0.6 2 2.375 3.25 1.8 2.00 1.3 1.88 1.2 1.38 1.0 4.38 2.5 2.75 1.8 DN50 603 83 0.8 51 0.6 48 0.5 35 0.5 111 1.1 70 0.8 21/2 2.875 3.75 3.2 2.25 2.2 4.001 2.3 1.50 1.1 5.13 3.4 3.00 2.8 73.0 95 1.5 57 1.0 102 1.0 38 0.5 130 1.5 76 1.3 3.000 3.75 3.7 2.25 3.4 2.25 1.50 0N65 76.1 95 1.7 57 1.5 57 - 38 - - - - - 3 3.500 4.25 4.5 2.50 3.1 4.501 3.1 1.50 2.1 5.88 6.0 3.38 4.9 DN80 88.9 108 2.0 1 64 1.4 114 1.4 38 1.0 1 149 2.7 86 2.2 31/2 4.000 450 56 275 43 250(sw) 40 175 (sw) 27 DN90 101.6 114 2.5 70 2.0 64 1.8 44 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 7.50 12.3 4.00 7.3 DN100 114.3 127 3.2 76 2.5 73 2.5 44 1.6 191 5.6 102 3.3 4.250 5.00 11.0 3.00 5.6 108.0 127 5.0 76 2.5 5.000 5.25 (sw) 10.0 3.13 (sw) 6.0 3.50 (sw) 6.6 1.88 (sw) 4.2 127.0 133 4.5 79 2.7 89 3.0 48 1.9 - - - - 5 5.563 5.50 11.7 3.25 8.3 2.88 (sw) 7.8 100 (sw) 5.0 9.25(5w) 18.0 4.88 (sw) 14.8 141.3 140 5.3 83 3.8 73 3.5 51 2.2 1 235 8.2 124 6.7 5.250 5.50 11.7 3.25 8.3 133.0 140 5.3 83 3.8 5.500 5.50 11.7 3.25 83 2.88 2.00 DN125 139.7 140 5.3 83 3.8 73 - 51 - - - - - 6 6.625 6.50 17.2 3.50 10.8 6.251 12.2 2.00 7.0 10.75 30.4 5.50 17.4 DN150 168.3 165 7.8 89 4.9 159 5.5 51 3.2 273 13.8 140 7.9 6.250 650 186 350 108 159.0 165 8.4 . 89 4.9 6.500 6.50 15.5 3.50 9.8 3.13 11.4 2.00 7.4 10.75 (sw) 29.0 5.50 (sw) 19.0 165.1 165 7.0 89 4.4 79 5.2 51 3.4 1 273 13.2 140 8.6 Gooseneck design, end-to-end dimension fittings in this size, contact your nearest Victaulic sales representative. (S) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victauliC.Com 4 tqJ(1tauIic 4.0 DIMENSIONS (CONTINUED) Elbows No. 10 900 Elbow No. 11450 Elbow -CtOE No. 12 22½° Elbow No. 13 111/40 Elbow rCtoE1 Cto( No. 100 900 Long C to No Radius Elbow Co Ct+ Radius Elbow o E . 110 45' Long t LV I I I I I I Standard and GSNK No. 100 No. 110 No. 10 No. 11 No. 12 No. 13 900 Long Radius 450 Long Radius Size 90" Elbow 45" Elbow 22W Elbow 11 ¼° Elbow Elbow Elbow Actual Approx. Approx. Approx. Approx. Approx. Approx. Outside Wgt. I Wgt. Wgt. Wgt. Wgt. Wgt. Nominal Diameter C to E (Each) C to E (Each) C to E Each C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg mm kg mm kg 8 8.625 7.75 29.9 4.25 20.4 7.751 20.0 2.00 10.1 14.25 66.0 7.25 36.0 DN200 219.1 197 13.6 108 9.3 197 9.1 51 4.6 362 30.0 184 16.3 10 10.750 9.00 63.3 4.75 37.5 4.38 (sw) 30.0 2.13 11.8 15.00 107.0 6.25 57.0 0N250 273.0 229 28.7 121 17.0 111 13.6 54 5.3 381 48.5 159 25.9 12 12.750 1000 740 525 667 4.88 (sw) 400 225 293 1800 1560 750 900 DN300 323.9 254 33.6 133 30.3 124 18.1 57 13.3 457 70.8 191 40.8 142 14.000 14.00 136.0 5.75 65.0 5.00 (sw) 46.0 3.50 (sw) 32.0 21.00(s) 164.0 8.75 82.0 DN350 355.6 356 61.7 146 29.5 127 20.9 1 89 14.5 1 533 74.4 222 37.2 14.843 14.84 149.3 6.13 82.0 377.0 377 67.7 156 37.2 162 16.000 16.00 171.0 6.63 88.0 5.00 (sw) 58.0 4.00 (sw) 42.0 24.00(s) 210.0 10.00(s) 100.0 DN400 406.5 406 77.6 168 39.3 127 26.3 102 19.1 610 95.3 254 45.4 16.773 16.75 198.6 7.00 101.3 _____ 426.0 425 90.1 178 45.9 182 18.000 18.00 228.0 7.50 108.0 5.50 (sw) 65.0 4.50 (sw) 53.2 27.00(s) 273.0 11.25(s) 135.0 DN450 457.2 457 103.4 190 50.0 140 29.5 1 144 24.1 1 686 123.8 1 286 61.2 18.898 18.88 291.0 7.83 141.7 480.0 480 132.0 200 64.3 202 20.000 20.00 298.0 8.25 138.0 6.00 (sw) 78.6 5.00 (sw) 65.0 30.00(s) 343.0 12.50(s) 174.0 DN500 508.0 508 135.2 210 62.6 152 36.0 127 29.5 762 155.6 318 78.9 20.866 20.88 355.0 8.63 179.0 _____ 530.0 530 161.0 219 81.2 242 24.000 24.00 438.0 10.00 221.0 7.00 (sw) 140.0 6.00 (sw) 60.0 36.00(s) 516.0 15.00(s) 251.0 DN600 609.6 1 610 1 198.7 1 254 1 100.2 1 178 1 63.5 1 152 27.2 914 234.1 381 1 113.9 24.803 24.80 545.0 10.25 255.2 630.0 630 1 247.2 1 261 1 115.7 For AGS fitting information, see publication 20.05 14-60 DN350-DN1500 A GS' Gooseneck design, end-to-end dimension fittings in this size, contact your nearest Victaulic sales representative. 2 For 14'/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (5w) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5 Aiata-uhcr victaulic.com 4.1 DIMENSIONS Reducing Base Support Elbow No. R-10G Grv. x Grv. No. R-10F Grv. x Flange CtoE-1 CtoE-.1 No. R-1O Size Reducing Base Support Elbow Approx. Weight Each Nominal C to E H B Diameter Grv. x Grv. Grv. x Flange inches inches inches inches lb lb DN mm mm mm kg kg 6 4 900 125 150 190 330 DN150 DN100 229 32 38 8.6 15.0 5 900 150 150 230 380 229 38 38, 10.4 17.2 8 6 10.50 2.13 1.50 33.0 52.0 DN200 DN150 267 24 38 15.0 23.6 10 8 1200 240 150 610 880 0N250 DN200 305 61 38 27.7 39.9 4.2 DIMENSIONS Adapter Elbow No. 18 90" Adapter Elbow No. 1945" Adapter Elbow C GE to Cto GE EO Q TE No. 18 No. 19 Size 90" Adapter Elbow 45" Adapter Elbow Actual Approximate Approx. Outside Weight Weight Nominal Diameter C to GE C to TE (Each) C to GE C to TE (Each) inches inches inches inches lb inches inches lb DN mm mm mm kg mm mm kg 3/4 1.050 2.25 2.25 ' 0.5 1.50 1.50 0.5 DN20 26.9 ' 57 57 ' 0.2 38 , 38 0.2 1 1.315 2.25 2.25 0.5 DN25 33.7 57 57 0.2 - - - 11/4 1.660 275 275 09 DN32 42.4 70 ' 70 0.4 11/2 1.900 2.75 2.75 1.1 1.75 1.75 0.9 DN40 48.3 70 70 0.5 44 44 0.4 2 ' 2.375 ' 3.25 , 4.25 2.5 DN50 60.3 ' 83 108 ' ' ' 1.1 - - - 21/2 2.875 3.75 3.75 3.0 2.25 2.25 2.3 73.0 95 95 1.4 57 57 1.0 3 3.500 4.25 6.00 5.8 2.50 . 4.25 5.0 DN80 ' 88.9 108 ' 152 2.6 64 . 108 2.3 31/2 4.000 4.50 6.25 8.0 5.25 5.25 8.8 DN90 101.6 1 114 159 3.6 133 133 L 4.0 6 6.625 6.50 ' 6.50 17.6 3.50 , 3.50 12.7 DN150 1683 165 165 80 89 89 58 NOTE Available with British Standard Pipe Threads, specify "BSP" clearly on order. 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com JtaUIiC victaulic.com 4.3 DIMENSIONS Tees, Crosses and True Wyes .• C to E GE C 0 C to TEEL~ No. 20 No. 35 No. 33 No. 29M Size Tee Cross (sw) True Wye (sw) Tee with Threaded Branch Actual Approx. Approx. Approx. Approx. Outside Weight Weight Weight Weight Nominal Dimeter C to E (Each) C to E (Each) C to LE C to SE (Each) C to GE C toTE (Each) inches inches inches lb inches lb inches inches lb inches inches lb DN mm mm kg mm kg mm mm kg mm mm kg 3/4 1.050 2.25 0.6 2.25 0.9 2.25 2.00 0.7 2.25 2.25 (sw) 0.6 DN20 26.9 57 0.3 57 0.4 57 51 0.3 57 57 0.3 1 1.315 2.25 1.0 2.25 1.3 2.25 2.25 1.1 2.25 2.25 1.0 DN25 33.7 57 0.5 57 0.6 57 57 0.5 57 1 57 0.5 11/4 1.660 2.75 1.5 2.75 2.1 2.75 2.50 1.5 2.75 2.75 1.5 DN32 42.4 70 0.7 70 1.0 70 64 0.7 70 70 0.7 11/2 1.900 2.75 2.0 2.75 2.5 2.75 2.75 1.8 2.75 2.75 2.0 DN40 48.3 70 0.9 70 1.1 70 1 70 0.8 70 70 0.9 2 2.375 3.25 3.0 3.25 3.8 3.25 2.75 2.5 3.25 4.25 3.0 DN50 60.3 83 1.4 83 1.7 83 70 1.1 83 108 1.4 21/2 2.875 3.75 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 4.3 73.0 95 2.0 95 2.8 95 76 2.0 95 95 2.0 3.000 3.75 5.2 3.75 3.75 (sw) 5.2 - DN65 76.1 95 2.4 - - - - 95 95 2.4 3 3.500 4.25 6.8 4.25 10.5 4.25 3.25 6.1 4.25 6.00 6.8 DN80 88.9 108 3.0 1 108 4.8 108 1 83 2.8 1 108 152 3.1 31/2 4.000 4.50 (sw) 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50 (sw) 7.9 DN90 101.6 114 3.6 114 5.2 114 89 4.4 114 1 114 3.6 4.250 5.00 15.5 5.00 5.00 (sw) 15.5 108.0 127 7.0 - - - - - 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 5.00 3.75 9.8 5.00 7.25 11.9 DN100 114.3 127 5.4 1 127 7.2 127 95 4.4 127 184 5.4 5.000 5.25 (sw) 15.0 5.25 18.5 5.25 5.25 (sw) 15.0 127.0 133 6.8 133 8.4 - - - 133 133 6.8 5.250 5.50 17.8 5.50 5.50 (sw) 17.8 133.0 140 8.1 - - - 140 140 8.1 5.500 5.50 17.8 5.50 5.50(sw) 17.8 DN125 139.7 140 8.1 - - - - - 140 140 8.1 5 5.563 5.50 17.8 5.50 20.0 5.50 4.00 15.0 5.50 5.50 (sw) 17.8 141.3 140 8.1 1 140 9.1 140 102 6.8 140 140 8.1 6.250 6.50 27.1 6.50 6.50 (sw) 27.1 159.0 165 12.3 - - - - 165 165 12.3 6.500 6.50 22.0 6.50 28.0 6.50 6.50(sw) 22.0 - 165.1 165 10.0 165 12.7 - - - - 165 165 10.0 6 6.625 6.50 25.7 6.50 28.0 6.50 4.50 22.3 6.50 6.50 (sw) 25.7 DN150 168.3 165 11.7 165 12.7 165 114 10.1 165 165 11.7 8 8.625 7.75 47.6 7.75 48.0 7.75 6.00 36.0 7.75 7.75 47.6 - DN200 219.1 197 21.6 197 1 21.8 197 152 16.3 197 21.6 10 10.750 9.00 99.0 9.00 121.5 9.00 6.50 69.9 99.0 DN250 273.0 229 44.9 229 55.1 229 155 31.7 229 49- 0( 449 12 12.750 10.00 133.0 10.00 110.0 10.00 7.00 80.0 10.00 133.0 DN300 323.9 254 60.3 254 49.9 254 178 36.3 254 60.3 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (5w) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com J(1tUIic• victaulic.com 4.3 DIMENSIONS (CONTINUED) Tees, Crosses and True Wyes w C to E to Cto"\ Cto GE ctIr I 2StE0 ____ _ No. 20 No. 35 No. 33 No. 29M Size Tee Cross (sw) True Wye (sw) Tee with Threaded Branch Actual Approx. Approx. Approx. Approx. Outside Weight Weight Weight Weight Nominal Dimeter C to E (Each) C to E (Each) C to LE C to SE (Each) C to GE C to TE (Each) inches inches inches lb inches lb inches inches lb inches inches lb DN mm mm kg mm kg mm mm kg mm mm kg 142 14.000 11.00 (sw) 1450 1100 1980 1100 750 1342 DN350 355.6 279 65.8 279 89.8 279 191 60.8 - T 377 • 0 11.50 145.0 292 65.8 162 16.000 1200(sw) 1860 1200 2500 1200 800 1670 DN400 4064 305 844 305 1134 305 203 757 - - - 426 • 0 13.00 186.0 300 84.4 182 18.000 15.50 (sw) 2600 1550 3500 1550 850 2340 DN450 457.0 394 117.9 394 158.8 394 216 106.1 - - - 4800 14.63 256.0 372 116.1 202 ________ 20000 17.25 (sw) 3360 17.25,4520 1725 900 2810 DNSOO 508.0 438 152.4 438 205.0 438 229. 127.5 - - - 530 • 0 15.38 (sw) 339.0 391 153.8 242 24.000 20.00 (sw) 5920 2000 7950 2000 1000 5230 DN600 6100 508 2685 508 3606 508 254 2372 - - - 6300 17.38(sw) 473.0 441 214.5 For AGS fitting information, see publication 20.05 14-60 DN350 - DN1500 A 65' 2 For 14"/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (SW) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (SW) or (5). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com j4tauIiC victaulic.com 4.4 DIMENSIONS Reducing Tee No. 25 Grooved Branch No. 29T Threaded Branch r.CtoE.l to to No. 25 No. 29T No. 291 No. 25 wl Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb DN mm mm kg 1 DN25 x 1 0N25 3/4 2.25 DN20 (sw) 57 2.25 (sw) 57 1.0 0.5 11/4 DN32 1 ¼ 0N32 1 0N25 2.75 (sw) 70 2.75 (sw) 70 1.3 0.6 1 ½ DN40 1 ½ DN40 3/4 DN20 2.75 (sw) 70 2.75 (sw) 70 1.5 0.7 2.75 (sw) 2.75 (sw) 1.5 1 0N25 70 70 0.7 2.75 (sw) 2.75 (sw) 1.7 11/4 DN32 70 70 0.8 2 DN50 2 DNSO 3/4 DN20 3.25 83 3.25 83 2.5 1.1 3.25 3.25 2.7 1 DN25 83 83 1.2 1 ¼ 3.25 (sw) 3.25 (sw) 1.8 DN32 83 83 0.8 1 ½ 3.25 3.25 (sw) 3.0 DN40 83 83 1.4 21/2 x 21/2 x 3/4 3.75 (sw) 3.75 (sw) 3.9 0N20 95 95 1.8 1 3.75 3.75 (sw) 3.8 0N25 95 95 1.7 3.75 3.75 4.2 1 ¼ DN32 95 95 1.7 3.75 3.75 3.9 1 ½ DN40 95 95 1.8 2 3.75 3.75 (sw) 4.5 0N50 95 95 2.0 3 DN80 3 DN80 3/4 0N20 4.25 (sw) 108 4.25 (sw) 108 5.7 2.6 4.25 4.25 6.1 1 DN25 108 108 1 2.8 4.25 4.25 8.0 1 ¼ DN32 108 108 3.6 4.25 4.25 (sw) 6.5 11/2 DN40 108 108 2.9 4.25 4.25 (sw) 6.2 2 DN50 108 108 2.8 21/2 4.25 4.25 (sw) 6.4 108 108 2.9 (5) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE Cast fitting available. Contact Victaulic for details. C to E Io No. 25 No. 291 No. 25 wl Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb ON mm mm I kg 4 DN100 4 DN100 3/4 DN20 5.00 (sw) 127 5.00 (sw) 127 8.0 3.6 5.00 5.00 7.8 1 DN25 127 127 3.5 5.00 (sw) 5.00 (sw) 9.6 1 ¼ 0N32 127 127 4.4 5.00 5.00 10.2 1 1/2 DN40 127 127 4.6 5.00 5.00 11.2 2 0N50 127 127 5.1 5.00 5.00 11.4 21/2 127 127 5.2 5.00 5.00 11.6 3 DN80 127 1 127 5.3 5 x 5 x 1 5.50 (sw) 5.50 (sw) 14.0 0N25 140 140 6.4 1 ½ 5.50 (sw) 5.50 (sw) 14.3 DN40 140 140 6.5 5.50 (sw) 5.50 (sw) 14.5 2 DNSO 140 140 6.6 21/2 5.50 5.50 (sw) 15.2 140 140 6.9 5.50 5.50 (sw) 16.6 3 DN80 140 140 7.5 5.50 5.50 (sw) 16.7 4 DN100 140 140 7.6 6 DN150 6 DN150 - 1 0N25 6.50 (sw) 165 6.50 (sw) 165 23.0 10.4 6.50 (sw) 6.50 (sw) 24.0 1 ½ DN40 165 165 10.9 2 6.50 6.50 21.6 DNSO 165 165 1 9.8 6.50 6.50 21.4 21/2 165 165 11.7 6.50 6.50 26.5 3 DN80 165 165 12.0 6.50 6.50 25.0 4 DN100 165 165 11.3 6.50 6.50 23.2 5 165 165 10.5 61/2 x 61/2 x 3 6.50 6.50 (sw) 24.0 DN80 165 165 10.9 4 6.50 6.50 (sw) 25.0 DN100 165 165 11.3 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE Cast fitting available. Contact Victaulic for details. C to El to No. 29T 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 9 jtauIicr victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 Grooved Branch No. 291 Threaded Branch .CtoE1 -CtoE.1 to to No. 25 No. 29T No. 291 No. 25 w/Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb DN mm mm kg 8 DN200 8 DN200 11/2 DN40 7.75 (sw) .197 7.75 (sw) 197 33.0 15.0 7.75 (sw) 7.75 (sw) 33.5 2 DN50 197 197 15.2 7.75 (sw) 7.75 (sw) 39.0 21/2 197 1 197 17.7 7.75 (sw) 7.75 (sw) 33.6 3 DN80 197 197 15.2 . 7.75 7.75 41.8 4 . DN100 197 197 19.0 7.75 (sw) 7.75 (sw) 34.0 5 197 197 . 15.4 7.75 7.75 42.3 6 DN150 197 197 19.2 7.75 (5w) 197 7.75 (5w) 197 48.0 21.8 1651 mm 10 DN250 10 DN250 1 ½ DN40 9.00 229 9.00 229 62.0 28.1 9.00 (sw) 9.00 (sw) 62.0 2 DNSO 229 229 28.1 9.00 (sw) 9.00 (sw) 62.4 21/2 229 229 28.3 9.00 (sw) 9.00 (sw) 60.0 3 DN80 229 229 27.2 9.00 (sw) 9.00 (sw) 61.0 4 DN100 229 229 27.7 9.00 (sw) 9.00 (sw) 52.0 5 229 229 23.6 9.00 (sw) 9.00 (sw) 59.0 6 DN150 1 229 229 1 26.8 1 9.00 (sw) 9.00 (sw) 64.7 8 DN200 1 229 229 29.3 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE Cast fitting available. Contact Victaulic for details. C to E.. . C to E to to No. 25 No. 29T No. 291 No. 25 W/ Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb DN mm mm kg 12 12 1 10.00 (sw) 10.00 (sw) 77.0 DN300 DN300 DN25 254 254 34.9 10.00 (Sw) 10.00 (sw) 80.0 2 DN50 254 254 36.3 10.00 (sw) 10.00 (sw) 78.0 21/2 254 . 254 35.4 10.00 (sw) 10.00 (sw) 82.0 3 DNSO 254 254 37.2 10.00 (sw) 10.00 (sw) 80.0 4 DN100 254 254 36.3 10.00 (sw) 10.00 (sw) 75.0 5 254 254 34.0 10.00 (sw) 10.00 (sw) 75.0 6 DN150 254 254 34.0 10.00 (sw) 10.00 (sw) 80.0 8 DN200 254 1 254 36.3 10.00 (sw) 10.00 (sw) 84.0 10 0N250 254 254 38.1 142 DN350 14 DN350 4 DN100 11.00 (sw) 279 11.00 (sw) 279 102.0 46.3 11.00 (sw) 11.00 (sw) 108.2 6 DN150 279 279 1 49.1 11.00 11.00 112.0 8 DN200 279 279 50.8 11.00 11.00 120.0 10 DN250 279 279 54.4 11.00 11.00 129.1 12 DN300 279 279 58.6 162 DN400 16 DN400 4 DN100 12.00 305 . 12.00 305 130.0 59.0 12.00 (sw) 12.00 (sw) 133.5 6 DN150 305 305 60.6 12.00 12.00 145.0 8 DN200 305 305 65.8 12.00 12.00 149.5 10 DN250 305 305 67.8 12.00 12.00 154.0 12 DN300 305 305 69.9 12.00(sw) . 167.0 14 DN350 305 - 75.8 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE Cast fitting available. Contact Victaulic for details. 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 10 \J$1tauIic victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee .l .- No. 25 Grooved Branch ______ CtoE. I CtoE No. 29T Threaded Branch ft -__[IL. [•f] C to E.] to No. 25 No. 29T No. 25 w/Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb DN mm mm kg 182 DN450 18 DN450 4 DN100 15.50 (sw) 394 15.50(5w) 394 194.0 88.0 15.50 (sw) 15.50 (sw) 200.0 6 DN150 394 394 90.7 8 15.50 (sw) 15.50 (sw) 202.0 DN200 394 394 91.6 15.50 15.50 212.0 10 DN250 394 394 1 96.2 15.50 15.50 222.6 12 DN300 394 394 101.0 14 15.50 230.1 0N350 394 - 104.4 15.50 247.6 16 DN400 394 - 112.3 202 20 6 17.25 17.25 240.0 DN500 DN500 DN150 438 438 108.9 17.25 17.25 244.0 8 0N200 438 438 110.7 17.25 17.25 256.0 10 DN250 438 438 116.1 12 17.25 17.25 264.0 DN300 438 438 119.8 17.25 275.0 14 0N350 438 - 124.7 17.25 288.6 16 DN400 438 - 130.9 17.25 297.0 18 DN450 438 - 134.7 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE Cast fitting available. Contact Victaulic for details. No. 29T No. 25 W/ Thd. Size Std. Branch Approx. Weight Nominal C to E C to E (Each) inches inches inches lb DN mm mm kg 242 24 8 20.00 20.00 340.0 DN600 0N600 DN200 508 508 154.2 20.00 20.00 343.9 10 DN250 508 508 156.0 20.00 20.00 352.8 12 DN300 508 508 160.0 20.00 360.0 14 DN350 508 - 163.3 20.00 378.0 16 DN400 508 - 171.5 18 20.00 380.0 DN450 508 - 172.4 20.00 373.0 20 DN500 508 - 169.2 For AGS fitting information, see 14-60 publication 20.05 DN350- 1500 A GS' 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTES No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. All fittings are ductile iron unless otherwise noted with an (sw) or (s). Cast fitting available. Contact Victaulic for details. r9 No. 29T No. 25 07.01 1449 Rev AFt Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 11 14tauiic victaulic.com 4.5 DIMENSIONS Bull Plug No. 61 E to E ED No. 61 No. 61 Size Bull Plug (s) Actual Approx. Outside Weight Nominal Diameter E to E (Each) inches inches inches lb DN mm mm kg 2 2.375 4.00 2.5 DN50 60.3 102 1.1 21/2 2.875 5.00 3.0 73.0 127 1.4 3 3.500 6.00 4.5 DN80 88.9 152 2.0 4 4.500 7.00 7.5 DN100 114.3 178 3.4 5 5.563 8.00 12.0 141.3 203. 5.4 6 6.625 10.00 17.0 DN150 168.5 254 7.7 (s) = Carbon Steel Direct Roll Groove (OGS) (Sw) = Carbon Steel Segmentally Welded NOTES Steel dish caps available through 24/DN600, contact Victaulic. No. 61 Bull Plugs should be used in vacuum service with Style 72 or 750 couplings. All fittings are ductile iron unless otherwise noted with an (aw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 12 X Aat-nulie victaulic.com 4.6 DIMENSIONS 45" Lateral No. 30 No. 30 No. 30 Size 45° Lateral Weight Actual Outside Approx. Nominal Diameter C to LE C to SE (Each) inches inches inches inches lb ON mm mm mm kg 3/4 1.050 4.50 (sw) 2.00 (sw) 1.0 DN20 26.9 114 51 0.5 1 1.315 5.00 (sw) 2.25 (sw) 1.7 DNJ25 33.7 127 57 0.8 11/4 1.660 5.75 2.50 2.5 (d) DN32 42.4 146 64 1.1 11/2 1.900 6.25 (sw) 2.75 (sw) 3.5 DN40 48.3 159 70 1.6 2 2.375 7.00 (sw) 2.75 (sw) 5.0 DNSO 60.3 178 70 2.3 21/2 2.875 7.75 (sw) 3.00 (sw) 9.0 73.0 197 76 4.1 3.000 8.50 (sw) 3.25 (sw) 11.0 0N65 76.1 216 83 5.0 3 3.500 8.50 3.25 11.7(d) DNSO 88.9 216 83 5.4 31/2 4.000 10.00 (sw) 3.50 (sw) 17.8 DN90 101.6 254 89 8.1 4 4.500 10.50 3.75 22.2(d) DN100 114.3 267 95 10.1 5 5.563 12.50 (sw) 4.00 (sw) 21.8 141.3 1 318 1 102 9.9 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded No. 30 No. 30 Size 45° Lateral Weight Actual Outside Approx. Nominal Diameter C to LE C to SE (Each) inches inches inches inches lb ON mm mm mm kg 6.500 14.00 (sw) 4.50 (sw) 43.6 165.1 356 114 19.8 6 6.625 14.00 (sw) 4.50 (sw) 43.6 DN150 1 168.3 356 1 114 49.8 8 8.625 18.00 (sw) 6.00 (sw) 72.0 0N200 219.1 457 152 32.7 10 10.750 20.50 (sw) 6.50 (sw) 105.0 DN250 273.0 521 165 47.6 12 12.750 23.00 (sw) 7.00 (sw) 165.0 DN300 323.9 584 178 74.8 142 14.000 26.50 (sw) 7.50 (sw) 276.0 DN350 355.6 673 191 125.2 162 16.000 29.00 (sw) 8.00 (sw) 344.2 DN400 406.4 737 203 156.1 182 18.000 32.00 (sw) 8.50 (sw) 429.0 0N450 457.0 1 813 216 194.6 202 20.000 35.00 (sw) 9.00 (sw) 500.0 DNSOO - 508.0 889 1 229 1 226.8 242 24.000 40.00 (sw) 10.00 (sw) 715.0 DN600 610.0 1016 254 324.3 For AGS fitting information, see publication 20.05 14-60 DN3SO-DN1Soo A GS 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (5w) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 13 '.j4tauiic No. 30-R No. 30-R victaulic.com 4.7 DIMENSIONS 45" Reducing Lateral No. 30-R No 30-R Size 450 Reducing Lateral Approx. Weight Nominal c to LE c to SE (Each) inches inches inches lb DN mm mm kg 3 3 2 8.50 3.25 9.8 DN80 DM80 DN50 216 83 4.4 8.50 3.25 9.8 21/2 216 83 4.4 4 4 2 10.50 3.75 10.0 DN100 DN100 DN50 267 95 4.5 10.50 3.75 10.0 21/2 267 95 4.5 10.50 3.75 18.3 3 DN80 267 95 8.3 5 x 5 x 2 12.50 4.00 24.0 DM50 318 102 10.9 12.50 4.00 27.0 3 DN80 318 102 12.2 12.50 4.00 26.5 4 DN100 318 102 12.0 6 DN150 6 DN150 3 DN80 14.00 356 4.50 114 37.0 16.8 14.00 4.50 36.0 4 DN100 356 114 16.3 14.00 4.50 44.7 5 356 114 20.3 8 DN200 8 DN200 4 DN100 18.00 457 6.00 152 62.0 28.1 18.00 6.00 75.5 5 457 152 34.2 18.00 6.00 82.0 6 DM150 457 152 37.2 10 DN250 10 x DN250 4 DN100 20.50 521 6.50 165 104.8 47.5 20.50 6.50 99.0 5 521 165 44.9 20.50 6.50 105.8 6 DM150 521 165 48.0 20.50 6.50 118.0 8 DN200 521 165 53.5 12 DN300 12 . DN300 5 23.00 584 7.00 178 122.0 55.3 23.00 7.00: 137.0 6 DN150 584 178 62.1 23.00 7.00 147.0 8 DN200 584 178 66.7 23.00 7.00 167.0 10 DN250 584 178 75.8 No 30-R Size 450 Reducing Lateral Approx. Weight Nominal C to LE C to SE (Each) inches inches inches lb DN mm mm kg 142 14 4 26.50 7.50 172.0 DN350 DN350 -DN 100 673 191 78.0 26.50 7.50 187.0 .6 DM150 673 191 84.8 26.50 7.50 205.8 8 DN200 673 191 93.4 26.20 7.50 235.0 10 DN250 673 191 106.6 26.50 7.50 250.0 12 DN300 673 191 113.4 162 16 6 29.00 8.00 215.0 DN400 DN400 DN150 737 203 97.5 29.00 8.00 252.5 8 DN200 737 203 114.5 29.00 8.00 265.0 10 DN250 737 203 120.2 29.00 8.00 295.0 12 DN300 737 203 133.8 29.00 8.00 305.0 14 DN350 737 203 138.3 182 18 6 . 32.00 8.50 274.0 DM450 x DM450 x DM150 813 216 124.3 32.00 8.50 275.0 8 DN200 813 216 1247 32.00 8.50 347.0 12 DN300 813 . 216 . 157.4 32.00 8.50 350.0 14 DN350 813 216 158.8 32.00 . 8.50 362.0 16 DN400 813 216 164.2 202 20 12 35.00 9.00 415.0 DNSOO DNSOO DN300 889 229 188.2 35.00 9.00 420.0 14 DN350 889 229 190.5 35.00 10.00 425.0 16 DN400 899 229 192.8 242 24 16 40.00 10.00 425.0 DN600 DN600 DN400 1016 254 192.8 40.00 10.00 570.0 20 DM600 1016 254 258.6 For AGS fitting information, 14-60 see publication 20.05 DM350- DN 1500 A 65' 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 14 JtaUIiC No. 32 C victaulic.com 4.8 DIMENSIONS Tee Wye No. 32 No. 32 Size Tee Wye (sw) Approx. Weight Nominal G H Ei E2 (Each) inches inches inches inches inches lb ON mm mm mm mm kg 2 2 2 2.75 7.00 9.00 4.63 6.4 DNSO 0N50 DNSO 70 178 229 118 2.9 21/2 21/2 21/2 3.00 7.75 10.50 5.75 11.5 x X 76 197 267 146 5.2 3 3 3 3.25 8.50 11.50 6.50 14.3 DN8O DN80 0N80 83 216 292 165 6.5 31/2 3½ 31/2 3.25 10.00 13.00 7.75 22.9 DN90 DN90 DN90 89 254 330 197 10.4 4 4 4 3.75 10.50 13.63 8.13 26.0 100 DN100 DN100 95 267 346 207 11.8 5 x 5 x 5 4.00 12.50 16.13 10.00 48.0 102 318 410 254 21.8 6 6 6 4.50 14.00 18.25 11.50 60.5 DN150 DN150 DN150 114 356 464 292 27.4 8 8 8 6.00 18.00 23.25 15.25 127.1 DN200 DN200 DN200 152 457 591 387 57.7 10 10 10 6.50 20.50 27.25 18.00 190.0 0N250 0N250 DN250 165 521 692 457 86.2 12 12 12 7.00 23.00 31.00 20.50 240.0 DN300 DN300 DN300 178 584 787 521 108.9 (5) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded 4.9 DIMENSIONS Adapter Nipple No. 4012 Grv. x Thd. No. 42 Grv. x Bev. No. 43 Grv. x Grv. -EtoE--.1 =- EtoE -.j .-EtoE-.1 I11 II1 tI I11IIII1I1 No. 40 No.42 No.43 No. 40, 42, 43 Size Adapter Nipple (s) Approx. Actual Outside Weight Nominal Diameter E to E (Each) inches inches inches lb ON mm mm kg 3/4 1.050 3.00 0.3 DN20 26.9 76 0.1 1 1.315 3.00 0.4 25 33.7 76 0.2 1 1/4 1.660 4.00 0.8 0N32 42.4 102 0.4 1 1/2 1.900 4.00 0.9 40 48.3 102 0.4 2 2.375 4.00 1.2 DN50 60.3 102 0.5 21/2 2.875 4.00 1.9 73.0 102 0.9 3 3.500 4.00 2.5 DN80 88.9 102 1.1 31/2 4.000 4.00 2.1 DN90 101.6 102 0.9 4 4.500 6.00 5.5 DN100 114.3 152 2.5 5 5.563 6.00 7.4 141.3 152 3.4 6 6.625 6.00 9.5 DN150 168.3 152 4.3 8 8.625 6.00 14.2 DN200 219.1 152 6.4 10 10.750 8.00 27.0 DN250 273.0 203 12.2 12 12.750 8.00 33.0 DN3001 323.9 203 1 15.0 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTES All fittings are ductile iron unless otherwise noted with an (sw) or (s). For pump package nipples with 1 W/40mm hole cut to receive Style 923 Vic-Letor Style 924 Vic-O-WeIl request special No. 40, 42 or 43 nipples and specify No. 40-H, 42-H or 43-H on order. NOTE: 4- 12'/DN100 - DN300 diameter - 8"/200 mm minimum length required. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. Available with British Standard Pipe Threads, specify "BSP" clearly on order. 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 15 '%J4tauIic victaulic.com 4.10 DIMENSIONS Cap No. 60 t No. 60 No. 60 Size Cap Actual Approx. Outside Weight Nominal Diameter "T" Thickness (Each) inches inches inches lb DN mm mm kg 3/4 1.050 0.88 0.2 DN20 26.9 22 0.1 1 1.315 0.88 0.3 25 33.7 22 0.1 11/4 1.660 0.88 0.3 DN32 42.4 22 0.1 11/2 1.900 0.88 0.5 DN40 48.3 22 0.2 2 2.375 0.88 0.6 DNSO 60.3 22 0.3 21/2 2.875 0.88 1.0 73.0 22 0.5 3.000 0.88 1.2 DN65 76.1 22 0.5 3 3.500 0.88 1.2 DN80 88.9 22 0.5 31/2 4.000 0.88 2.5 DN90 101.6 22 1.1 4.250 1.00 2.3 108.0 25 1.0 4 4.500 1.00 2.5 DN100 114.3 25 1.1 5.250 1.00 4.5 133.0 25 2.0 5.500 1.00 4.5 DN125 139.7 25 2.0 5 5.563 1.00 4.6 141.3 25 2.1 b No. 60 No. 60 Size Cap Actual Approx. Outside Weight Nominal Diameter "1" Thickness (Each) inches inches inches lb DIN mm mm kg 6.250 1.00 6.8 159.0 25 3.1 6.500 1.00 7.3 165.1 25 3.3 6 6.625 1.00 6.1 DN150 168.3 25 2.8 8 8.625 1.19 13.1 DN200 219.1 30 1 5.9 10 10.750 1.25 21.0 DN250 273.0 32 9.5 12 12.750 1.25 35.6 DN300 323.9 32 16.2 142 14.000 9.50(s) DN350 355.6 241 + 162 16.000 10.00(s) DN400 406.4 254 + 182 18.000 11.00(s) DN450 457.0 279 + 202 20.000 12.00(s) DN500 508.0 305 + 242 24.000 13.50(s) DN600 610.0 343 + For AGS fitting information, see publication 20.05 14-60 DN350-DN1500 A65" 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded + Contact Victaulic for details. NOTES No. 60 cap is not suitable for use in vacuum service with Style 72 or 750 couplings. No. 61 bull plugs should be used. All fittings are ductile iron unless otherwise noted with an )sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 16 Jtaulid victaulic.com 4.11 DIMENSIONS Flanged Adapter Nipple No. 45F ANSI Class 150 Flat Face No. 45R ANSI Class 150 Raised Face No. 46F ANSI Class 300 Flat Face No. 46R ANSI Class 300 Raised Face No. 45RE PN10/PN16 Raised Face EtoE ftoE f.- EtoE to EtoE - No. 45F No. 45R No. 46F No. 46R No. 45RE No. 45F and No. 45R No. 46F and No. 46R ANSI 150 ANSI 300 No. 45RE Size Flanged Adapter Nipple (s) Flanged Adapter Nipple (s) Flanged Adapter Nipple Actual Outside Approx. Weight Approx. Weight Approx. Weight Nominal Diameter £ to E (Each) E to E (Each) (Each) inches inches inches lb inches lb =EE lb DN mm mm kg mm kg kg 3/4 1.050 3.00 2.3 3.00 3.3 DN20 1 26.9 76 1.0 76 - 1.5 - 1 1.315 3.00 2.7 3.00 3.9 DN25 33.7 76 1.2 76 1.8 - - 11/4 1.660 4.00 3.3 4.00 4.8 DN32 42.4 102 1.5 102 2.2 - - 11/2 1.900 4.00 3.9 4.00 6.9 DN40 48.3 102 1 1.8 102 3.1 - - 2 2.375 4.00 6.0 4:00 8.2 2.50 5.3 DN50 60.3 102 2.7 102 3.7 64 2.4 21/2 2.875 4.00 9.9 4.00 11.9 73.0 102 4.5 1 102 5.4 - - 3.000 2.50 6.5 0N65 76.1 - - - - 64 2.9 3 3.500 4.00 11.7 4.00 16.5 2.50 8.2 DN80 88.9 102 5.3 102 7.5 64 3.7 31/2 4.000 4.00 15.1 4.00 20.1 DN90 101.6 102 6.8 102 9.1 - - 4 4.500 6.00 18.5 6.00 27.4 2.75 10.0 DN100 114.3 152 8.4 152 12.4 70 45 5 5.563 6.00 21.3 6.00 35.3 141.3 152 9.7 152 16.0 - - 5.500 2.75 16.3 DN125 139.7 - - - - 70 7.4 6 6.625 6:00 27.5 6.00 47.5 2.75 16.3 DN150 168.3 152 12.5 152 21.5 70 7.4 6.500 165.1 8 8.625 6.00 41.3 6.00 70.3 DN200 219.1 152 : 18.8 152 31.9 - 10 10.750 8.00 59.3 8.00 100.8 DN250 273.0 203 27.1 203 45.7 - - 12 12.750 8.00 40.0 8.00 146.2 DN300 323.9 203 40.0 203 66.3 - - 142 14.000 8.00 8.00 DN350 355.6 203 + 203 162 16.000 8.00 8.00 DN400 406.4 203 + 203 182 18.000 8.00 8.00 DN450 457.0 203 + 203 + - - 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = carbon Steel Direct Roll Groove (OGS) (5w) = carbon Steel Segmentally Welded 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic company. All rights reserved. victaulic.com 17 jtuIic 4.11 DIMENSIONS (CONTINUED) Flanged Adapter Nipple No. 45F ANSI Class 150 Flat Face No. 45R ANSI Class 150 Raised Face No. 46F ANSI Class 300 Flat Face No. 46R ANSI Class 300 Raised Face No. 45RE PN10/PN16 Raised Face EtoE— 1—EtoE- h- EtoE -. - EtoE -. - No. 45F No. 45R No. 46F No. 46R No. 45RE No. 45F and No. 45R No. 46F and No. 46R ANSI 150 ANSI 300 No. 45RE Size Flanged Adapter Nipple (s) Flanged Adapter Nipple (s) Flanged Adapter Nipple (s) Actual Outside Approx. Weight Approx. Weight Approx. Weight Nominal Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 202 20.000 8.00 8.00 DN500 508.0 203 + 203 242 24.000 8.00 8.00 DN600 610.0 203 + 203 1+ - - For AGS fitting information, see publication 20.05 14-60 DN350- DN1SOO A65'" 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (s) = Carbon Steel Direct Roll Groove (OGS) (5w) = Carbon Steel Segmentally Welded + Contact Victaulic for details NOTE All fittings are ductile iron unless otherwise noted with an (Sw) or (5). 07.01 1449 Rev AFt Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 18 victaulic.com 4.12 DIMENSIONS Swaged Nipple No. 53 Grv. x Grv. No. 54 Grv. x Thd. No. 55 Thd. x Grv. to E - E to E -. i.- E to E D~ Dj E> No. 53 No. 54 No. 55 No. 53, 54, and 55 Swaged Size Nipples (s) Approx. Weight Nominal E to E (Each) inches inches lb DN mm kg 2 1 DNSO DN25 6.50 165 2.0 0.9 6.50 2.0 11/4 DN32 165 0.9 6.50 2.0 11/2 DN40 165 0.9 21/2 1 DN25 7.00 178 3.0 1.4 7.00 3.0 11/4 DN32 178 1.4 7.00 3.0 11/2 DN40 178 1.4 7.00 3.0 2 DN50 178 1.4 3 1 DN80 DN25 8.00 203 4.5 2.0 8.00 4.5 1 ¼ DN32 203 2.0 8.00 4.5 11/2 DN40 203 2.0 8.00 4.5 2 DNSO 203 2.0 8.00 4.5 21/2 203 2.0 31/2 3 8.00 6.8 DN90 DN80 203 3.1 4 1 9.00 7.5 DN100 DN25 229 3.4 9.00 7.5 11/4 DN32 229 3.4 9.00 7.5 11/2 0N40 229 3.4 9.00 7.5 2 DNSO 229 3.4 9.00 7.5 21/2 229 3.4 3 9.00 7.5 DN80 229 3.4 9.00 7.5 31/2 DN90 229 3.4 E to E .- E to E -. >- E to E LZ30 L-/31 I I E> No. 53 No. 54 No. 55 No. 53, 54, and 55 Swaged Size Nipples (s) Approx. Weight Nominal E to E (Each) inches inches lb DN mm kg 5 2 DNSO 11.00 279 11.5 5.2 3 11.00 11.3 DN80 279 5.1 11.00 11.5 4 DN100 279 5.2 6 1 DN150 DN25 12.00 305 17.0 7.7 12.00 17.0 1¼ DN32 305 7.7 11/2 12.00 17.2 DN40 305 7.8 12.00 17.4 2 DN50 305 7.9 12.00 17.4 21/2 305 7.9 3 12.00 17.4 DN80 305 7.9 31/2 12.00 17.4 DN90 305 7.9 12.00 17.5 4 DN100 305 7.9 12.00 17.5 41/2 305 7.9 12.00 17.5 5 305 7.9 8 6 DN200 DN150 + 20.0 9.1 (s) = Carbon Steel Direct Roll Groove (OGS) (SW) = Carbon Steel Segmentally Welded + Contact Victaulic for details NOTE All fittings are ductile iron unless otherwise noted with an (sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 19 J.1tQUIiC vktiailirnm 4.13 DIMENSIONS 4.14 DIMENSIONS Female Threaded Adapter Hose Nipple No. 80 E to E No. 80 Size No. 80 Female Threaded Adapter Actual Approx. Outside Weight Nominal Diameter E to E (Each) inches inches inches lb DIN mm mm kg 3/4 1.050 2.00 1.0 DN20 26.9 51 0.5 1 1.315 2.06 1.0 0N25 33.7 52 0.5 1¼ 1.660 2.31 (sw) 1.5 DN32, 42.4 59 0.7 11/2 1.900 2.31 (sw) 1.5 DN40 48.3 59 0.7 2 2.375 2.50 1.4 DN50 60.3: : 64 0.6 21/2 2.875 2.75 1.5 73.0 70 0.7 3 3.500 2.75 2.9 DN80 88.9 70 1.3 4 4.500 3.25 4.5 DN100 114.3 1 83 2.0 (s) = Carbon Steel Direct Roll Groove (OGS) (SW) = Carbon Steel Segmentally Welded NOTES Available with British Standard Pipe Threads, specify "BSP" clearly on order. All fittings are ductile iron unless otherwise noted with an (SW) or (s). No. 48 E to E No. 48 Size No. 48 Hose Nipple (s) Approx. Actual Outside Weight Nominal Diameter E to E (Each) inches inches inches lb DIN mm mm kg 3/4 1.050 . : 3.12 0.3 DN20 26.9 79 0.1 1 1.315 3.38 0.4 DN25 33.7 86 0.2 .1 ¼ . 1.660 3.88 0.6 DN32 42.4 98 0.3 11/2 1.900 3.88 0.8 DN40 48.3 98 0.4 2 2.375 4.50 1.1 DN50 60.3 114 0.5 21/2 2.875 5.38 2.0 73.0 137 0.9 3 3.500 5.75 3.2 DN80 88.9 146. 1.5 4 4.500 7.00 4.9 DN100 114.3 178 2.2 5 5.563 8.75 8.0 141.3 222 3.6 6 6.625 10.13 14.3 DN150 168.3 257 6.5 8 . 8.625 11.88 . 24.7 DN200 219.1 302 11.2 10 10.750 12.50 40.1 DN250 273.0 318 18.2 12 : 12.750 14.50 62.0 DN300 323.9 368 28.1 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTE All fittings are ductile iron unless otherwise noted with an (SW) or (s). 07.01 1449 Rev AR Updated 07/2022 tB 2022 Victaulic Company. All rights reserved. victaulic.com 20 \j4tau11c victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric toE ltoE - E to E - - E to E -~] E to E Etc E *- E to F E to E - Eld No. 50 No. 51 Fabricated Steel Fabricated Steel No. 50 No. 51 Fabricated Steel Fabricated Steel No. 50 No. 51 No. 50 No. 51 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DN mm kg mm kg 1¼ 1/4 1.9 DN32 DN20 + 0.9 - 1 1.9 DN25 + 0.9 - - 1½ 3/4 1.4 0N40 DN20 + 0.6 - - 1 2.50 0.8 8.50 (sw) 4.5 0N25 64 0.4 1 216 2.0 11/4 2.50 1.0 DN32 64 0.5 - - 2 ~ 2.50 0.9 9.00 (sw) 2.0 DNSO DN20 64 0.3 229 0.9 1 2.50 0.7 9.00 (sw) 2.3 DN25 64 1 0.3 229 1.0 11/4 2.50 1.2 9.00 (sw) 4.6 DN32 64 0.5 229 2.1 11/2 2.50 1.0 3.50 1.1 0N40 64 0.5 89 1 0.5 21/2 3/4 1.3 3.3 DN20 + 0.6 + 1.5 1 2.50 1.1 9.50 3.5 DN25 64 1 0.5 241 1.6 1 1/4 3.50 3.3 3.50 1.4 DN32 89 1.5 89 0.6 11/2 2.50 3.6 9.50 (sw) 3.7 DN40 64 1.6 241 1.7 2 2.50 3.9 3.50 4.3 DNSO 64 1.8 89 2.0 3 3/4 1.5 4.5 DN80 0N20 + 0.7 + 2.0 1 2.50 1.3 9.50 (sw) 4.8 DN25 64 0.6 241 2.2 11/4 2.50 1.4 4.8 DN32 64 0.6 + 2.2 1 1/2 2.50 5.1 9.50 (sw) 5.1 DN40 64 2.3 241 2.3 2 2.50 1.6 3.50 6.0 DNSO 64 1 0.7 89 2.7 21/2 2.50 1.8 3.50 7.0 64 0.8 1 89 3.2 DN65 2.50 2.1 64 1.0 31/2 3 2.50 2.0 9.50 (sw) 7.0 DN90 DN80 64 0.9 241 3.2 4 1 3.00 3.0 13.00 (sw) 6.5 DN100 DN25 1 76 1 1.4 1 330 1 2.9 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DN mm kg mm kg 1¼ 4.6 0N32 + 2.1 - - 11/2 3.00 (sw) 2.6 10.00 (sw) 8.1 DN40 76 1 1.2 254 3.7 2 3.00 2.4 4.00 3.3 DN50 76 1.1 102 1.5 21/2 3.00 2.7 4.00 3.4 76 1.2 1 102 1.5 3 3.00 3.2 4.00 3.5 DN80 76 1.4 102 1.6 31/2 3.00 2.9 10.00 (sw) 8.0 DN90 76 1.3 254 3.6 5 2 11.00 (sw) 9.0 11.00 (sw) 5.2 DNSO 279 1 4.1 279 2.4 21/2 4.00 4.3 11.00 (sw) . 10.8 102 2.0 279 4.9 3 4.00 5.5 11.00 (sw) 11.1 DN80 102 2.5 279 5.0 4 3.50 4.3 5.00 12.0 DN100 89 1.9 127 5.4 6 1 4.00 5.0 11.50 (sw) 14.5 0N150 DN25 102 1 2.3 292 6.6 1½ 5.5 + 2.5 + + 2 4.00 6.6 11.50 (sw) 14.5 DN50 102 3.0 292 6.6 21/2 4.00 6.4 11.50 (sw) 14.2 102 2.9 292 6.4 3 4.00 6.4 5.50 15.0 0N80 102 1 2.9 140 6.8 4 4.00 6.5 5.50 17.0 DN100 102 2.9 140 7.7 5 4.00 6.4 5.50 17.0 102 2.9 140 7.7 8 21/2 16.00 7.9 12.00 (sw) 26.1 DN200 406 3.6 305 11.8 3 5.00 9.3 12.00 (sw) 22.0 DNSO 127 1 4.2 305 10.0 4 5.00 10.4 12.00 (sw) 23.0 DN100 127 4.8 1 305 10.4 5 5.00 11.6 12.00(s 23.0 127 5.2 305 10.4 6 5.00 11.9 6.00 24.0 DN150 127 5.4 152 10.9 07.01 1449 Rev AH Updated 07/2022 © 2022 Victauflc company. All rights reserved. victaulic.com 21 \jtGluIid 4.15 DIMENSIONS (CONTINUED) -- Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric toE 4-EtoE-31 f4-EtoE-31 - EtoE No. 50 No. 51 Fabricated Steel Fabricated Steel No. 50 No. 51 No. 50 concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DIN mm kg mm kg 10 4 6.00 19.7 13.00 (sw) 32.0 DN250 DN100 152 . 8.9 330 14.5 5 33.0 34.6 H + 15.0 + 15.7 6 6.00 20.0 13.00 (sw) 36.9 DN150 152 9.1 330 16.7 8 6.00 22.0 7.00 21.6 DN200 152 10.0: 178 9.8 12 4 44.0 14.00 (sw) 48.0 DN300 DN100 + 20.0 356 21.8 6 7.00 24.6 14.00 (sw) 50.0 DN150 178 11.2 356 22.7 8 7.00 52.0 14.00 (sw) 53.5 DN200 178 23.6 356 243 10 7.00 39.0 14.00 (sw) 57.0 DN250 178 17.7 356 25.9 142 .6 13.00 65.0 13.00 60.0 DN350 DN150 330 . 29.5 330 27.2 8 13.00 65.0 13.00 60.0 DN200 330 29.5 330 27.2 10 13.00 66.0 13.00 65.0 DN250 330 29.9 330 29.5 13.00 68.0 13.00 66.0 12 DN300 330 30.8 330 29.9, 162 8 14.00 73.0 14.00 73.0 DN400 DN200 356 33.1 355 33.1 10 14.00 73.0 14.00 73.0 DN250 356 33.1 355 33.1 12 14.00 73.0 14.00 73.0 DN300 356 33.1 355 33.1 14 14.00 73.0 14.00 73.0 DN350 356 33.1 355 33.1 182 10 15.00 91.0 15.00 .91.0 DN450 .DN250 381 413 381 41.3 12 15.00 91.0 15.00 91.0 DN300 381 41.3 381 41.3 14 15.00 91.0 15.00 91.0 DN350 381 41.3 1 381 41.3 16 15.00 91.0 15.00 91.0 DN400 381 41.3 381 41.3 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. *-EtoE-i1 4-EtoE-e. +-EtoE n~ EJ 7 No. 50 No. 51 Fabricated Steel Fabricated Steel No. 50 No. 51 No. 50 Concentric No. 51 Size Reducer Eccentric Reducer Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb inches lb DN mm kg mm kg 202 . 10 20.00 . 110.0 20.00 177.0 DNSOO . DN250 508 49.9 508 80.3 20.00 120.0 20.00 120.0 12 DN300 508 54.4 508 54.4 14 20.00 149.0 20.00 149.0 DN350 508 67.9 1 508 67.9 16, 20.00 120.0 20.00 120.0 0N400 508 54.4 508 54.4 18 20.00 136.0 20.00 136.0 DN450 508 .61.7 508 61.7 242 10 20.00 142.0 20.00 142.0 DN600 DN250 508 64.4 508 64.4 12 20.00 150.0 20.00 150.0 DN300 508 68.0 1 508 68.0 14 20.00 162.0 20.00 162.0 DN350 508 73.5 508 73.5 16 20.00 162.0 20.00 162.0 DN400 508 73.5 508 73.5 18 20.00 162.0 20.00 162.0 0N450 508 73.5 508 73.5 20 20.00 151.0 20.00 190.0 DN500 508 68.5 508 86.2 For AGS fitting information see publication 20.05 14-60 DN350- DN1SOO A65- 2 For 14/DN350 and larger roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales representative. (5) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded + Contact Victaulic for details. NOTES Available with male threaded small end No. 52. Cast fitting available for JIS size. Contact Victaulic for details. Steel eccentric reducers available through 30"/DN750, contact Victaulic for dimensions. All fittings are ductile iron unless otherwise noted with an (sw) or (s). I 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 22 JtaUIic victaulic.com 4.16 DIMENSIONS Small Threaded Reducer No. 52 No. 52F E E E E 1 -toE.1 r-toE 1.-toE.1 to El DUO DUO No. 52 No 52F No. 52 No 52F No. 52F Concentric No. 52 Reducer with BSPT Size Small Threader Reducer Female Threaded End Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb ON mm kg I mm kg 1½ 1 2.50 0.8 DN40 0N25 64 0.4 - - 1'/4 2.50 0.9 DN32 64 0.4 - - 2 3/4 2.50 0.9 0N50 DN20 64 0.4 - - 1 2.50 0.7 0N25 64 0.3 - - 1 ¼ 2.50 1.2 DN32 64 0.5 - - 1 1/2 2.50 1.0 DN40 64 0.5 - - 21/2 1 2.50 1.1 x_2!5 64 0.5 - - 11/4 2.50 (sw) 1.2 DN32 64 0.5 - - 11/2 2.50 (sw) 1.3 DN40 64 0.6 - - 2 2.50 1.4 DN50 64 0.6 - - x DN65 r'o 64 0.8 64 0.8 - 64 0.9 DNSO - 1/4 +(sw)0.7 1.5 - - X0N20 DN80 2.50 1.3 1 DN25 64 0.6 - - 11/4 2.50 1.5 DN32 64 0.7 - - 11/2 2.50 (sw) 1.5 - DN40 64 0.7 - 2 2.50 1.5 0N50 64 0.7 - - 21/2 2.50 2.4 64 1.1 88.9mm x 42.4mm 64 0.9 64 0.8 64 0.9 64 0.9 48.3mm 60mm - - 64 0.9 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded + Contact Victaulic for details. No. 52F Concentric No. 52 Reducer with BSPT Size Small Threader Reducer Female Threaded End Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb DN mm kg mm kg 4 1 3.00 2.3 DN100 DN25 76 1.0 - - 1 1/2 3.00 2.7 0N40 76 1.2 - - 2 3.00 2.6 DN50 76 1.2 - - 21/2 3.00 2.6 76 1.2 3 3.00 2.5 DN80 76 1.1 - - 108.0mm x 42.4mm 76 1.3 76 1.3 48.3mm 76 1.3 76 1.4 60mm - - 76 1.4 114.3mm x 42.4mm 76 1.3 76 1.3 48.3mm 76 1.3 76 1.3 60mm 76 1.3 76 1.4 5 4 4.5 DN100 + 2.0 - - 133.0mm x 60mm - - 114 2.2 139.0mm x 60mm - - 114 2.3 6 1 4.00 5.5 DN150 DN25 102 2.5 - - 2 4.00 5.7 DN50 102 2.6 - - 21/2 4.00 5.8 102 2.6 3 4.00 5.8 DN80 102 2.6 - - 4 +(sw) 6.5 DN100 2.9 - - 5 +(sw) 2.0 09 - - 159.0mm x 42.4mm 114 2.2 144 2.5 48.3mm 114 2.2 114 2.5 60mm - - 114 2.6 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 23 \,41tauIic victaulic.com 4.16 DIMENSIONS (CONTINUED) Small Threaded Reducer No. 52 No. 52F E -to E-1 E D U No. 52 No 52F No. 52 No. 52F Concentric Small Threader Reducer with BSPT Size Reducer Female Threaded End Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb DN mm kg mm kg 165.1mm x 42.4mm 102mm 2.4 102 2.9 102mm 2.6 102 3.0 48.3mm - 102 3.0 60mm 8 2 DN200 DNSO 16.00 406 1.5 0.7 - - 16.00 1.7 2 1/2 406 0.8 (s) = Carbon Steel Direct Roll Groove (OGS) (sw) = Carbon Steel Segmentally Welded NOTES Available with British Standard Pipe Threads, specify "BSP' clearly on order. All fittings are ductile iron unless otherwise noted with an (sw) or (s). 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 24 \ Ai t -au I id victaulic .com 5.0 PERFORMANCE Flow Data (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/2" elbow is approximately one-half the resistance of a 45" elbow. Values of mid-sizes can be interpolated. Size Dimensions 90 Elbows 45 Elbows Tees Actual No. 100 No. 110 Outside No. 10 1½ D Long No. 11 1½ D Long Nominal Diameter Std. Radius Radius Std. Radius Radius Branch Run inches inches feet feet feet feet feet feet DN mm meters meters meters meters meters meters 1 1.315 1.7 0.8 - 4.2 1.7 DN25 33.7 0.5 - 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 DNSO 60.3 1.1 0.8 0.5 0.3 2.6 1.1 3.000 4.3 2.1 10.8 4.3 DN65 76.1 1.3 - 0.7 - 3.3 1.3 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 DN80 88.9 1.5 1.2 0.8 0.5 4.0 1.5 4.250 6.4 3.2 15.3 - 6.4 108.0 2.0 - 0.9 - 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 DN100 114.3 2.1 1.5 1.0 0.6 4.9 2.1 5.250 8.1 4.1 20.0 8.1 133.0 2.5 - 1.2 - 6.2 2.5 5.500 8.5 4.2 21.0 8.5 0N125 139.7 2.6 - 1.3 - 6.4 2.6 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 - 1.3 - 6.4 2.6 6.250 9.4 4.9 25.0 9.6 159.0 2.9 - 1.5 - 7.6 2.9 6.500 9.6 5.0 25.0 10.0 165.1 -2.9 - 1.5 - 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 DN150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 DN200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 0N250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 DN300 323.9 6.1 4.4 3.0 1 1.8 15.2 6.1 14 14.000 24.54 15.8 18.54 11.0 70.0 23.0 DN350 355.6 7.5 4.8 5.6 3.4 21.3 7.0 16 16.000 28.04 18.0 21.0 13.0 80.0 27.0 DN400 406.4 8.5 5.5 6.4 4.0 24.4 8.2 18 18.000 31.04 20.0 23.54 14.0 90.0 30.0 DN450 457.0 9.5 6.1 7.2 4.3 27.4 9.1 20 20.000 34.04 22.5 25.54 16.0 100.0 33.0 DN800 508.0 1 10.4 6.9 7.8 4.9 30.5 10.1 24 24.000 42.04 27.0 29.54 19.0 120.0 40.0 DN600 -610.0 12.8 8.2 9.0 5.8 36.6 12.2 AGS fittings available up to 607DN 1500. Contact Victaulic for details. AGS" 4 Fitting flow data for 14-247DN350-DN600 size No. 10 and No. 11 Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. W10 and No. Wil Elbows), refer to publication 20.05. 07.01 1449 Rev AH Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 25 11 ~. 0 4i -C -ta _U1 i C r victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as lathe suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provisional Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grunt any license under any patent or other intellectual properly right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United Stales and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available is PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 07.01 1449 Rev All Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 26 \,hltaulici TED APPROVED Approval Details and Limitations, rebsite at www.anvilinit.com or 1Anvila Sales Representative. DUCTILE IRON THREADED FITTINGS (~)AWIL FIG, 3201 9O Elbow FIGURE 32.1 Isi ELBOW Nominal Size Maximum Dimension A Approx. WI. Each Working Pressurea, In. (mm) PS! (kPa) in. (mm) lhs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 lA 500 1.75 0.90 32 3450 44.45 0.41 1½ 500 1.94 1.20 40 3450 49.216 0.54 2 500 2.25 1.85 50 3450 51.15 0.84 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UI/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME 81 .20.1 Agency Approvals: All ductile iron threaded fittings are UI/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: Approved Address: [-]Approved as noted Contractor: iJ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 - M-COAT® sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-10/Schedule-40 - M-COAT gives you the extra quality assurance you demand. Our Sch-10 (1-1/4" - 8") pipe and Sch-40 (1" - 2-1/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. ® Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "M-COAT". American Made Manufactured at one of 3 U.S. Facilities and is available through distributors in the USA, Canada, Mexico, and Latin America. ® Specifications & Approvals Schedule-10/Schedule-40 M-COAT pipe are in compliance with the following: ASTM A135, Type E, Grade A, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. U. I NPS Nominal Nominal I.D. Nominal Wt. WI. (H20 Filled) CR8 ln;mni 0.D. In: mm In; mm Wall In: mm Lbs/Ft; kglm lbslFt; kQlm 1' 1.315 1.049 0.133 1.680 2.05 1 25 33.4 26.6 3.38 2.5 3.05 - 1¼" 1.660 1.380 0.140 2.270 2.93 1 32 42.1 35.1 3.56 3.39 4.36 - 1112" 1.900 1.610 0.145 2.720 3,61 1 40 48.3 40.9 3.68 4.0 5.37 - 2" 2.375 2.067 0.154 3.656 5.13 50 60.3 52.5 3,91 5.4 7.63 - 2½ 78 --. 203 __ -5_ --- -.16 - -14--- _ 1jy I. U NPS ¼ Nominal Nominal I.D. Nominal Wt. WI. (H20 Fill CRR 1,14. Mm 'jn; mm In; mm Wall In: mm Lbs/Fl; kq/m Lbs/Ft m - 1¼" 1.442 0.109 1.810 25 70955 16N 42. 36.6 2.77 2.7 /5 - 1½" 1.900 ",,1.682 0.109 2.09 3,04 5.6570 40 48.3 97 2.77 4.52 - 2" 2.375 2.l5"'...,, 0.109 . 4.22 4.5827 50 60.3 54.8 2.77 3.9 6.28 - 21b" 2.875 2.635 1 3.530 5.89 3.5196 65 73 66.9 5.26 8.77 - 0 3.260 / 0.120 " 4.34 7.94 25550 9 3.05 11.82 - 0 ,r(0 0.120 \,.,6. ,,,,,, 11,78 16020 .3 ____ 08.20 3.05 8,3 17.53 5.295 0.134 - ,/ 7.78 ...4,.33 1.4874 a 134.5 3.40 11.58 5 .3 .80 6.357 0.134 9.3 23 10251 161.5 3,40 34 " 5 13.8 8,249 0.188 16.96 40.15 9 209.50 4.78 25.2 59.75 0 co <~~> APPROVED *Not available with M-Coat Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Pallied TUBE & CONDUITS Customer Service: (800) 882-5543 Fax: (800) 659-7730 16100 S Lathrop Ave • 11350 Norcom Rd. Harvey, IL 60426 Philadelphia, PA 19154 www.alliedtube-sprinkler.com 2525 N 27th Ave. Phoenix, AZ 85009 02013 Atkore International, Inc. All Rights Reserved. STP-S3-4M-1301 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 10 Pipe 05&ainaft I IL 11 1 1.315 1.097 1.41 lbs/ft 91 11/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe "11' @ ((11) 15mimloave IF F @aal @W I I 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific filling used. C®uS Chesterfield, MO 63017 contact your salesperson 1819 Clarkson Road For additional information, (800) 3256 -4467 today at (800) 325-4467 or LISTED 8 ILL. MOOSE TUBE COMPANY FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada ACCAPRQcompany e-mail: sa1esbu11moosthjbe.com call (800) 882-4666 <i > ______ APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 q C --)> DUCTILE DRON THREADED FITTINGC, FIG. 3224 Cap rn IFIGURE 3224 CAP Nominal Size MaximumDimension A Working PressureA Approx. Wt. Each In. (mm) PS! (kPa) In. (mm) tbs. (kg) 500 1.16 0.32 25 3450 29.46 0.15 11/4 500 1.28 0.43 32 3450 32.51 0.20 11/2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 1 36.83 0.41 A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. ®s USTED APPROVED For UstingslApproval Details and Lunitations, visit our website at www.anvilintl.com or contact an Anvil* Sales Representative. Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: []Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 DUCTILE IRON THREADED FITTINGS FIG. 3221 Coupling USTEO APPROVED For UstingsiApproval Details and Limitations, visit our website at www.anoilintl.com or Contact an Anvil' Soles Representative. FIGURE 32°4 .[u1i1 II [c Nominal Size Maximum Dimension A Approx. Wt. Each Working PressureA In. (mm) PSI (Vu) In. (mm) Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 1¼ 501) 1.93 0.57 32 3450 49.02 0.26 1V2 501) 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 1 3450 64.26 0.52 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-1 2 Finish: Black Threads: NPT per ASME B 1 .20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. IPROJECT INFORMATION APPROVALSTAMP Project: Approved Address: []Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1.15 Cs'P —F/ F:; Nv-"11L= DUCTILE URON THREADED FITTINW: FIG. 3388 Cored Plug j[t USTED APPROVED For UstingslApproval Details and Umitations, visit our website at w.anvilintl.com or contact an Anvil' Sales Representative. FIGURE 33::] (CORED PLUG Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 500 0.94 0.10 15 3450 23.87 0.05 1/4 500 1.07 0.17 20 3450 27.11 0.08 1 500 1.25 0.28 25 3450 31.15 0.13 ]l/4 500 1.36 0.44 32 3450 34.54 0.20 11/2 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.4/ A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. MATERIAL SPECIFICATIONS Dimensions: ASME B16.]4 Material: ASTM A536 Grade 65-45-] 2 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. A Pressure - Temperature Ratings in accordance with ASME 816.3 Class 150 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: IJ Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-5.1 6 DUCTILE IRON THREADED FITTINGS (~).JXWIL FIG, 3201R Reducing 90 Elbow - B 2 i I 1x2 FIGURE 3201R REOUCIIVG1I. ELBOW Nominal Size Max. Working PressureA Dimensions Approx. Wt. Each 1 x 2 A B In. (mm) PSI ON In. (mm) In. (mm) Lbs. (kg) 1 x ½ 500 1.26 1.36 0.44 25x!5 3450 32.00 34.54 0.20 1 x 144 500 1.37 1.45 0.52 25x20 3450 34.79 36.83 0.24 11/4 x ½ 500 1.34 1.53 0.64 32x 15 34550 34.03 38.86 0.29 1½ x '/4 500 1.45 1.62 0.72 32x20 1 3450 36.83 41.14 0.33 1½ x 1 500 1.58 1.61 0.75 32x25 3450 40.13 42.41 0.34 1½ x 1 500 1.65 1.80 0.92 40x25 3450 41.91 45.72 0.42 1½ x 1½ 500 1.82 1.88 1.08 40x32 3450 46.22 47.75 0.49 2x½ 500 1.49 1.88 1.08 50x 15 3450 37.84 47.75 0.49 2 x 1/4 500 1.60 1.97 1.24 50x20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.07 1.40 50x25 3450 43.94 51.30 0.64 2x1½ 500 1.90 2.10 1.52 50x32 1 3450 48.26 533d 0.70 2 x 1112 500 2.02 2.16 1.65 50x40 3450 51.30 54.86 1 0.75 A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.cam or contact your local Anvil Representative. Da us <3> SlED APPROVED Approval Details and Limitations, nebsite at an,w.anvilintl.com or fl Anvil° Sales Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-1 2 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded Fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATI ON Project: []Approved Address: [-]Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1 .15 DUCTILE iTHREADED FITTI NGS FIG. 3221R Reducing Coupling c®us USTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.onsitrntl.com or contact on Anvil* Solos Representative. FIGURE c}°__I::1: 1uIslkl[eIu1uJ1IR[c Nominal Size MaximumDimension A Approx. WI. Each Working PressureA In. (mm) PSI (kPa) In. (mm) tbs. (kg) 500 1.69 0.39 25x15 3450 42.92 0.18 1 x'/4 500 1.69 0.53 25x20 1 3450 42.92 1 0.24 11/4 x 3/4 500 2.06 0.64 32x20 3450 52.32 0.29 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest ULJIJLC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASIM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. !I!1Il lINFORMATION A1 J;I'ITi.i STAMP Project: Approved Address: I1Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-5.1 9 c®Us USTED APPROVED tings/Approval Details and Limitations, our website at www.anvilintl.com or tact as Anvil Sales Representative. FIG. 3205R Reducing Tee I 1J B '11 T A 1 x2x3 DUCTILE IRON THREADED FITTINGS FIGURE 32'.1 : REDUCIPJGtTEE Nominal Size Max. Working Dimensions Approx. t. Each 1 x 2 x 3 Pressurea, A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) tbs. (kg) 1 X Vt x 1 500 1.50 1.36 1.50 0.64 25x 15x25 3450 38.10 34.54 38.10 0.29 1 x 3% x 1 500 1.50 1.45 1.50 0.73 25x20x25 3450 38.10 36.83 38.10 0.33 1 x x Vt 500 1.26 1.26 1.36 0.71 25x25x 15 3450 32.00 32.00 34.54 0.32 1 X xth 500 1.37 1.37 1.45 0.76 25x25x20 3450 34.80 34.80 1 36.83 0.34 1 x 1 x 14* 500 1.67 1.67 1.58 0.98 25x25x32 3450 42.41 42.41 40.13 0.44 1 X x 1/2* 500 1.80 1.80 1.65 1.16 25x25x40 3450 45.72 45.72 41.91 0.53 1 Vt x 1 x ½* 500 1.34 1.26 1.53 0.82 32x25x15 3450 34.04 32.00 38.86 0.37 1% x 1 x 3/4 500 1.45 1.37 1.62 0.90 32x25x20 1 3450 36.83 34.80 41.15 0.41 1¼ x 1 x 1 500 1.58 1.50 1.67 1.00 32x25x25 3450 40.13 38.10 42.42 0.45 1¼ x 1 x 1¼ 500 1.75 1.67 1.75 1.08 32x25x32 3450 44.45 42.42 44.45 0.49 1% x 1 x 1/2 500 1.88 1.80 1.82 1.42 32x25x40 1 3450 1 47.15 1 45.72 1 46.22 0.64 1¼ x 1144 x Vt 500 1 3450 1.34 1 34.04 1 1.34 1 1.53 0.86 32x32x 15 34.04 38.86 0.39 Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded Fittings are UL/ULC listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. FIGURE Nominal Size Max. Working PressureA Dimensions Approx. Wt. LOt 1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) tbs. (kg) P/tx 1¼x 3/4 32x32x20 500 3450 1.45 36.83 1.45 36.83 1.62 1 41.15 0.92 0.42 11% x 1¼ x 1 32x32x25 500 3450 1.58 40.13 1.58 40.13 1.67 42.42 0.95 0.43 1% x 1% x 1/2* 32x32x40 500 3450 1.88 47.15 1.88 41.15 1.82 46.22 1.45 0.66 A Working Pressure Ratings are for reference only and based an Sch. 40 pipe. For the latest tJL/UIC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Port supplied as "Bull Head Tee". PROJECT INFORMATION Project: 0 Approved Address: [-]Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 > DUCTILE IROIM THREADED FITTINGS FIG. 3205R Reducing Tee -4- C L 1x 2x3 FIGURE 32'-1 : REDUCIPJGi I: Nominal Size Max. Working Dimensions , ppox t. Each 1 x 2 x 3 PressureA A B C In. (mm) PSI (kPo) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11hx 11/4 x 2* 500 2.10 2.10 1.90 1.75 32x32x50 3450 53.34 53.34 48.26 0.79 11/2 X 1 X 1/2 500 1.41 1.34 1.66 0.95 40x25x15 3450 35.81 34.04 42.16 0.43 1½x1x3/4 500 1.52 1.37 1./5 1.14 40x25x20 3450 38.61 34.80 44.45 0.52 1½x lxi 500 1.65 1.50 1.80 1.17 40x25x25 3450 41.91 38.10 1 45.72 0.53 11/2 x 1 x I ¼ 500 1.82 1.67 1.88 1.34 40x25x32 3450 46.23 42.42 47.75 0.61 1 '/2 x 1 x 1/2 500 1.94 1.80 1.94 1.45 40x25x40 3450 49,28 45.72 49.28 0.66 1'/2x1½X'/2 500 1.41 1.34 1.66 1.05 40x32x15 3450 35.81 34.04 42.16 0.48 i'/2x1¼x/4 500 1.52 1.45 1.75 1.15 40x32x20 3450 38.61 36.83 44.45 0.5 1/i x 11/4 x 1 500 1.65 1.58 1.80 1.25 40x32x25 3450 41.91 40.13 1 45.72 0.57 1/2 xl ¼ x 2* 500 2.16 2.10 2.02 1.90 40x32x50 3450 54.86 53.34 51.30 0.86 1'/sxl'/ixV2 500 1.41 1.41 1.16 1.15 40x40x15 3450 35.81 35.81 29.46 0.52 11/2 x 11/2 x 3/4 500 1.52 1.52 1.75 1.24 40x40x20 3450 38.61 38.61 44.45 0.56 1 '/2 x 1 '/2 x 1 500 1.65 1.65 1.80 1.30 40x40x251 3450 41.91 41.91 45.72 0.59 1½ x 11/2 x 11/4 500 1.82 1.82 1.88 1.48 40x40x32 3450 1 46.23 46.23 47.75 0.67 FIGURE 32'-1 :UREDUCIPJGtTEE Nominal Size Max. Working Dimensions Approx. Wt. LOC I x 2 x 3 PressureA A B In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1½x 1½x 2* 500 2.16 2.16 2.02 1.98 40x40x50 3450 54.86 54.86 51.30 0.90 2 x x 2 500 2.25 2.02 2.25 2.15 50x25x50 3450 57.15 51.31 57.15 0.98 2 x 11/4 x 2 500 2.25 2.10 2.25 2.30 50x32x50 3450 51.15 53.34 57.15 1.04 2x11/2 x 1/2 500 1.49 1.41 1.88 1.50 50x40x15 3450 37.85 35.81 47.75 0.68 2 x 11/2 x 3/4 500 1.60 1.52 1.97 1.62 50x40x20 3450 40.64 38.61 50.04 0.73 2 x 11/2 x 1 500 1.73 1.65 2.02 1.64 50x40x25 3450 43.94 41.91 51.31 0.74 2x11/2 x11/4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 2 x 11/2 x 11/2 500 2.02 1.94 2.16 2.00 50x40x40 3450 51.31 49.28 54.86 0.91 2 x 11/2 x 2 500 2.25 2.16 2.25 2.35 50x40x50 3450 57.15 54.86 57.15 1.07 2x2x 1/2 500 1.49 1.49 1.88 1.60 50x50x15 3450 31.85 37.85 47.75 0.73 2 x 2 x 3/4 500 1.60 1.60 1.97 1.68 50x50x20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50x50x25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11/4 500 1.90 1.90 2.10 2.04 3450 44.45 42.42 44.45 0,93 r50x50x32 2 x 2 x 1½ 500 2.02 2.02 2.16 2.18 50x50x40 1 3450 44.45 42.42 44.45 0,99 A Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Bull Head Teen. SPF/Dl-1.15 USTED APPROVED ings/Approval Details and Umitatiorss, our website at wwa.anvillntt.com or act an Anvil Sales Representative. RNVIL DUCTILE IRON THREADED FITTINGS FIG, 3205 Straight Tee A 1. A -4- A FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Dimension A Approx. Wt. Each Working PressureA In. (mm) PSI (kPo) In. (mm) tbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 1/4 SOD 1.75 1.22 32 3450 44.45 0.55 1½ 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 1 3450 1 57.15 1 LII A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UI/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASIM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded Fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron Fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECTI INFORMATION lIi1 APPROVAL STAMP Project: 0 Approved Address: E] Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 Victaulic® FireLockTM Outlet-T SJtaUIiC Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 -2 1/2'YDN32—DN65 Threaded Outlet Sizes: 1/'/DN15, 3/4 /DN20, and 17DN25 NOTE IGS Grooved 1/DN25 Outlets available for this product. See oublication 10,54. Maximum Working Pressure 300 psi/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS c®us :0 USTED 0~pcs fEUK CA LIPS 1186: EN 10311 BS EN 10311 Issue 3.1 CPR (Eu) CPR (UK) Cert/LPCB No. 305/2011 2019 No, 465 Ref. 491a/27 NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.52 3355 Rev K Updated 07/2022 © 2022 Victaulic company. All rights reserved. 1 JtauIic victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange coating. Red coating (standard for EMEA-I and Asia Pacific). Optional: Contact Victaulic with your requirements for other coatings. Gasket': O Grade 'E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40T/-40C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). 10.52 3355 Rev K Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2 'j'(ctauIicr victaulic.com 4.0 DIMENSIONS Style 922 is"asm-NI-si, Style 922 Size Bolt/Nut - Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm - mm mm mm mm mm mm kg 11/4 1/2 1.660 0.840 1.30 1.83 1.10 3.87 2.56 1 0N32 DN15 42.4 21.3 2 3/8 X 13/8 33 47 28 98 65 0.5 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 DN20 26.9 2 3/ x 1 /e 33 47 28 98 65 0.5 1.52 218 110 387 256 1 1 1.315 DN25 2 /8 x 1 /8 39 55 28 98 65 0.5 1½ 1/2 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 2 ~x1~ 36 50 31 104 65 0.5 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 DN20 26.9 2 ~x 1% 36 50 31 104 65 0.5 1.64 2.30 1.22 4.08 2.56 1 1 1.315 0N25 2 ~x 1 % 42 58 31 104 65 0.6 2 1/2 2.375 0.840 2 .66 142 2.19 1.46 4.60 - 2.56 1 50 DN15 60.3 21.3 3/8 X13/8 - 56 37 117 65 0.6 1 64 2.19 1.46 460 256 1 3/4 1.050 DN20 26.9 2 ~x13/s 42 56 37 117 65 0.6 2 - - 1.88 - 2.54 1.46 4.60 - 2.56 2 - 1 1.315 0N25 ~ x 11/8 48 - 65 37 117 65 0.7 21/2 1/2 2.875 0.840 1.91 2.44 1.71 5.40 2.56 2 DN15 73.0 21.3 2 3/8 X1% 49 62 43 137 65 0.7 1.89 2.44 1.71 5.40 2.56 2 3/4 1.050 DN20 26.9 2 ~ X 1 /8 48 62 43 137 65 0.7 2 2.13 2.79 1.71 5.40 2.56 2 1 1.315 DN25 /8 xl ~ 54 71 43 1 137 65 0.7 DN65 1/2 3.000 0.840 191 244 171 550 256 2 - DN15 76.1 - 21.3 2 ~x1~ 49 62 43 140 65 0.7 1.89 2.44 1.71 5.50 2.56 2 3/4 - 1.050 - DN20 26.9 2 - 3/. x 13/. 48 62 43 140 65 0.7 - 2.13 2.79 1.71 5.50 2.56 2 - 1 - 1.315 - 0N25 2 ~ xl ~ 54 71 - 43 .140 65 .0.8 - 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev K Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 'js4'tauiic 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet ON meters meters 11/4 1 8.5 12.5 DN32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25_ 2.6 3.8 2 1 8.5 12.5 DNSO DN25 2.6 3.8 21/2 1 8.5 12.5 DN25_ 2.6 3.8 1 8.5 12.5 DN65 DN25 2.6 3.8 - Hazen-Williams coefficient of friction is 120. F FireLock1' Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING son ypl~ 1 * 0 9 0 is Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes 1I16 1¼ 30 32 10.52 3355 Rev K Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com ri \JtaUIiC victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 1 1/4xY2 300 300 300 232 232 232 DN32XDN15 2068 2068 2068 1600 1600 1600 1 1/4X'/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1¼x1 300 300 300 232 232 232 DN32XDN25 2068 2068 2068 1600 1600 1600 1½x'/2 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1½xN4 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1½x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2X1/2 300 300 300 232 232 232 DN50XDN15 2068 2068 2068 1600 1600 1600 2x3/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1. 300 300 300 232 232 232 DN50XDN25 2068 2068 2068 1600 1600 1600 21/ux1/a 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x3/4 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2'/2x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 - 300 232 232 232 DN65XDN25 - - 2068 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide 29.01: Victaulic Terms and Conditions of Sale 1-100: Installation Instructions 1-922: Installation Instructions FireLockTM Outlet-I User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries, Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on Wechat. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic company, and/or its affiliated entities, in the U.S. and/or other countries. 10.52 3355 Rev K Updated 07/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 'Psj$(tauIic 3. HANGERS & BRACING Pipe Hangers TOLCOTM Fig. 200 - "Trimline" Adjustable Band Hanger TOLCOTM Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCOTM Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCO Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed around pipe. 1/2" (15mm), 3/4" (20mm), and 21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S A C@ US Overall Height LISTED APPROVED B Center of pipe to top of knurled hanger rod nut. 0 Top of pipe to bottom of hanger rod nut. Fig. 200-'/2& 2O0-/4 ID1" Fig. 200-2/2 to 200-8 Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUI) for steel and CPVC plastic pipe and Fig. Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). 2001 to Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 2002 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°c) 4191 0 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts mfn 4P 1 in place of a knurl nut. Order By: Part number and pipe size Q C AL Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or 200Mb-i 1/2 Fig 200C Fig. 200F Fig. 200 Fig. 200 & Fig. 2005 200C-11/2 shown 200E-1'/2 shown shown with captured nut shown with 1" thru 2" sizes only non-captured nut Pipe Size Rod Size A B 0 Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm* in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-1/2 /2" (15) /8"-16 M8 or M10 31/8" (79.4) 2/8" (66.7) 111/32" (34.1) 480 (1.78) 11 (5.0) 200-/4 3/4" (20) /8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) /8"-16 MB or M10 33/8" (85.7) 2/8' (66.7) 11/8' (28.6) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) /8"-16 MB or M10 33/4" (94.0) 2/8" (73.0) 1/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 I 11/2" (40) /8"-16 MB or MiD 3/8" (98.4) 2/e" (73.0) 1/16" (30.2) 400 (1.78) 14 (6.4) 200-2 2° (50) /8"-16 MB or MiD 41/2° (114.3) 3" (76.3) 1/16" (30.2) 400 (1.78) 15 (6.9) 200-2'/2 21/2" (65) /8"-16 M10 5I8" (142.9) 41/8" (104.7) i'/it" (36.5) 600 (2.67) 27 (12.3) 200-3 3" (75) /8"-16 MiD 5/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 200-31/2 . 31/2" (90) /8"-16 MiD 73/8" (187.3) 51/4" (133.3) 2/16" (55.6) 600 (2.67) 34 (15.6) 200-4 4" (100) /8"-16 MiD 7 /8" (187.3) 5" (127.0) 1/8" (34.9) 1000 (4.45) 35 (16.0) 200-5 5° (125) 1/2 .13 M12 91/8" (231.8) 61/4" (158.7) 311/32" (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"13 M12 101/8' (257.2) 6/4" (171.4) 2/32" (56.3) 1250 (5.56) 73 (33,4) 200-8 8" (200) 1/2"_13 M12 131/8" (333.4) 8/4" (222.2) 3/32' (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) B32051 - Threaded Rod (right & left hand threads) Size Range: /8'-16 thru /8"-9 rod Material: Steel Function Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F 1399°C) Finish: Plain or Electro-Ga Ivan ized. Contact customer service for alternative finishes and materials. Order By: Figure number, rod size, length and finish TL Specify Length < TL Wead Size 0000 Standard Design Load Thread Size Thread Length TI 650°F (343°C) 150°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-318 x 'I' /8"-16 2'/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 X '1' 1/2"13 21/2' (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x 'I' /8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-314 x 1' /4"-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3205-/8 x 'I' /8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog ATR - All Threaded Rod - 120" (3.05m) Lengths TOLCOTM Fig. 99 - All Threaded Rod Cut To Length Size Range: 1/4'20 thru /'-9 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F 1399°Cl Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. Order By: Figure number, rod size, length and finish Part No. - Size x Length Threads Recommended load Approx. Wt./100 Ft. ATR Fig. 99 Per Inch Lbs. (kN) Lbs. (kg) AIR 1/4" x 120 99-/4" x length 20 240 (1.07) 12 (5.44) ATR /8" x 120 993/8" x length 16 730 (3.24) 29 (13.15) ATR /2" x 120 99-1I2" x length 13 1350 (6.00) 53 (24.04) ATR /" x 120 99-/8" x length 11 2160 (9.60) 89 (40.37) ATR 3/4" x 120 993/4" x length 10 3230 (14.37) 123 (55.79) ATR /" x 120 997/g" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 96 B-Line series Fire Protection Solutions Hydraulic Calculations for Project Name: RACEWAY UPS CONVEYORS: (5D0269) Location: 3125 LIONSHEAD AVE. CARLSBAD, CA. 92008, Drawing Name: 5D0269 RACEWAY CONVEYORS Design Remote Area Number: 1 Remote Area Location: PLATFORM Occupancy Classification: Ordinary Group II Commodity Classification: ORDINARY HAZARD Calculation Date: 5/17/2024 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual 1721ft2) 130ft2 Upright 15 0 N/A gpm at Node: 250.00 at Node: N/A 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 818.19 @ 100.357 (Safety Margin = 20.041) Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A Name of Contractor: Hiller Fire Address: 7130 CONVOY CT, SAN DIEGO, CA. 92111 Phone Number: 858-277-3473 Name of designer: BEN LEDESMA Authority Having Jurisdiction: : CARLSBAD Notes: Automatic peaking results Left: 100.357 Right: N/A 1A© M.E:P.CAD AutoSPRlNK 2023 v18. 1.38.0 1 5/17/2024 8:27:13AM Page 1 a- 60 0 75 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 150- 135 120 105 30 15 I Supply Summary Sheet Node: I Static Pressure 120.600 18.19 Q 120.398-.......... - 1818.19 with Hose Allowance at 568.19 @ 100.357 Source - 10001.00 c ystem demand curve _..Irj.1JJ.1.LIIIIIIIII IllIltIlt Ilillilti 111th III liii II I II II I I I I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 5/17/2024 4600 6900 9200 5750 8050 10350 Flow - gpm Supply:static:i 20.600 Residual:99.900 Flowing: 10001.00 Available Flow @ 20 PSI:23486.72 ,© M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 5/17/2024 8:27:15AM Page 2 11500 III [inmary Of Outfiowing Devices Job Number: SD0269 Report Description: Ordinary Group 11 (1) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 2852 48.01 26.00 8 36.017 Sprinkler 2853 41.28 26.00 8 26.628 Sprinkler 2854 47.79 26.00 8 35.692 Sprinkler 2855 40.28 26.00 8 25.357 Sprinkler 2893 43.98 26.00 8 30.227 Sprinkler 2894 34.42 26.00 8 18.510 Sprinkler 2895 43.78 26.00 8 29.950 Sprinkler 2925 30.96 26.00 8 14.973 Sprinkler 2954 39.84 26.00 8 24.802 Sprinkler 2955 26.86 26.00 8 11.272 Sprinkler 2956 39.66 26.00 8 24.573 Sprinkler 2964 26.95 26.00 8 11.350 Sprinkler 2970 39.28 26.00 1 8 1 24.104 1 c Sprinkler 2971 26.00 26.00 8 10.563 Sprinkler 2972 ]777 39.09 26.00 8 23.881 c. Most Demanding Sprinkler Data , © M.E.P.CAD AutoSPRINK 2023 08.1.38.0 5/17/2024 8:27:16AM Page 3 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Supply Analysis Node Name Static (psi) Residual Flow (psi) (g pm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 120.600 99.900 10001.00 120.398 818.19 100.357 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4-0 Supply 100.357 568.19 2852 12-7% Sprinkler 36.017 48.01 2853 12-7% Sprinkler 26.628 41.28 2854 12-7% Sprinkler 35.692 47.79 2855 8-6 Sprinkler 25.357 40.28 2893 1271/2 Sprinkler 30.227 43.98 2894 12-7% Sprinkler 18.510 34.42 2895 12-71/2 Sprinkler 29.950 43.78 2925 8-6 Sprinkler 14.973 30.96 2954 12'-71/2 Sprinkler 24.802 39.84 2955 12'-7% Sprinkler 11.272 26.86 2956 12'-71/2 Sprinkler 24.573 39.66 2964 8-6 Sprinkler 11.350 26.95 2970 127h/2 Sprinkler 24.104 39.28 2971 12'-7% Sprinkler 10.563 26.00 2972 12'-71/2 Sprinkler 23.881 39.09 22 4-0 90.377 23 4-0 91.238 ik,© M.E.P.CAD AutoSPRINK 2023 v18.1.38. 5/17/2024 8:27:19AM Page 4 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: I Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 24 4-0 91.238 27 4-0 90.643 30 4-0 91.238 31 4-0 91.238 101 39'-6 69.811 128 39-6 69.866 188 39'-6 69.811 192 39-6 69.866 443 39'-6 69.810 445 39-6 69.867 508 39-6 69.810 510 39'-6 69.869 562 39'-6 69.809 564 39'-6 69.872 639 39-6 69.809 641 39-6 69.877 711 39'-6 69.807 713 39-6 69.884 765 39-6 69.806 767 39'-6 69.895 819 39-6 69.804 821 39-6 69.908 &©M.E.P.CAD JAutoSPRlNK 2023 v18.1.38. 5/17/2024 8:27:19AM Paqe5 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 870 39-6 69.802 900 13-0 66.067 902 11'-6 61.483 903 13'-0 65.576 906 13-0 65.485 918 39-6 69.808 920 39-6 69.926 957 11-6 40.410 958 11-6 30.067 959 11-6 40.051 960 8-6 26.714 961 11-6 29.216 977 39-6 69.876 979 39'-6 69.950 1064 11-6 34.034 1065 11-6 21.104 1066 11-6 33.729 1114 8-6 15.807 1115 11-6 16.843 1126 39-6 69.944 1128 39-6 69.979 1215 39-6 70.008 ,© M.E.P.CAD AutoSPRINK 2023 v18.1.38. 5/17/2024 8:27:19AM Paqe 6 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1217 39-6 70.011 1254 11-6 28.053 1255 11-6 13.089 1256 11-6 27.800 1274 8-6 11.996 1275 11-6 12.503 1284 11'-6 27.282 1285 11-6 12.301 1286 11-6 27.036 1302 39-6 70.071 1304 39'-6 70.043 1395 39'-6 70.135 1397 39-6 70.071 1512 39-6 70.205 1514 39'-6 70.097 1620 39-6 70.278 1622 39'-6 70.118 1959 39-6 70.355 1961 39'-6 70.132 2290 39'-6 70.437 2292 39-6 70.141 2467 39'-6 70.833 ,© M.E.P.CAD j AutoSPRINK 2023 v18.1 .38. 5/17/2024 8:27:19AM Paqe 7 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 2479 39 -6 70.831 2481 39'-6 70.153 2559 0-0 89.010 2564 0-0 91.238 2569 13-0 91.238 2571 0-0 91.238 (&© M.E.P.CAD friflAutoSPRINK 2023 08.1.38. 5/17/2024 8:27:19AM Paqe 8 Job Nme: RAtEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 2971 1271/2 8 26.00 1 (See Notes) 11Y2 120 10.563 Route 1 ..... PO(5'-l0) 5-10 0.181014 0.480 1285 11-6 26.00 1.0830 6111/2 1.258 1285 11-6 .1,, 4-6 120 12.301 0.044894 1275 11'-6 26.00 1.4420 4'6 0.202 1275 11 -6 26.95 1 3-6 120 12.503 Flow (q) from Route 3 0.167368 1255 11'-6 52.95 1.4420 3'6 0.586 1255 11 -6 26.86 1 10'-6 120 13.089 Flow (q) from Route 2 0.357529 1115 11'-6 79.81 1.4420 10-6 3.754 1115 11 -6 30.96 1 1 6-6 120 16.843 Flow (q) from Route 4 0.655626 1065 11-6 110.77 1.4420 6-6 4.262 1065 11 -6 34.42 1 7-6 120 21.104 Flow (q) from Route 5 1.081574 961 11'-6 145.19 1.4420 7-6 8.112 961 11 -6 40.28 1 0-6 120 29. 216 Flow (q) from Route 10 1.701383 958 11'-6 185.47 1.4420 0-6 0.851 958 11'-6 41.28 11/4 (See Notes) 5-3% 120 30.067 Flow (q) from Route 11 PO(T-5) 2.467538 902 11-6 226.75 1.4420 12'-9 31.416 902 11-6 2 (See Notes) 1'6 120 61.483 PO(13'-7%) 13-7'/2 0.313288 -0.650 903 13-0 226.75 2.2030 15'-1'/2 4.743 903 13-0 170.33 14-7% 120 65.576 Flow (q) from Route 6 0.033626 900 13'-0 397.08 4.3100 147h/2 0.491 900 13-0 171.11 4 (See Notes) 160-10 120 66.067 Flow (q) from Route 7 2P0(27-10%), BV(16-8%) 72'-51h 0.065248 -11.488 870 39'-6 568.19 4.3100 233-4 15.223 , © M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 9 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) __________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 870 39-6 6 0'-10% 120 69.802 0.007395 -0.000 918 39-6 487.10 6.3570 0-10'/2 0.006 918 39-6 6 9-8 120 69.808 0.007055 977 39'-6 474.89 6.3570 9-8 0.068 977 39'-6 6 10-0 120 69.876 0.006797 1126 39-6 465.43 6.3570 10-0 0.068 1126 39-6 6 9-8 120 69.944 1215 39-6 459.11 6.3570 0.006628 9-8 0.064 1215 39-6 6 9-6 120 70.008 0.006588 1302 39'-6 457.64 6.3570 9-6 0.063 1302 39-6 5.66 6 9-6 120 70.071 Flow (q) from Route 16 1395 39-6 463.30 6.3570 0.006740 9-6 0.064 1395 39'-6 8.74 6 10-0 120 70. 135 Flow (q) from Route 26 0.006977 1512 39-6 472.04 6.3570 10'-O 0.070 1512 39'-6 11.61 6 101-0 120 70.205 Flow (q) from Route 22 1620 39-6 483.64 6.3570 0.007298 10-0 0.073 1620 39-6 14.40 6 10-0 120 70. 278 Flow (q) from Route 23 1959 39-6 498.04 6.3570 0.007705 10-0 0.077 1959 39-6 17.21 6 10-0 120 70. 355 Flow (q) from Route 35 0.008204 2290 39-6 515.24 6.3570 10-0 0.082 2290 39'-6 20.07 6 (See Notes) 7'3 120 70.437 Flow (q) from Route 20 P0(37-8%) 37'-8V2 0.008805 2467 39-6 535.31 6.3570 45-01/2 0.397 (/,©M.E.P.CAD jAutoSPRlNK 2023 v18.1.38.O 1 5/17/2024 8:27:21AM Page 10 Job Name: RAtEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pfl and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 2467 39'-6 32.88 6 (See Notes) 51'8 120 70.833 Flow (q) from Route 17 T(37'-8%), E(17'-7) 55'4 0.009832 17.124 2559 01-0 568.19 6.3570 107-0 1.052 2559 01-0 8 (See Notes) 3'0 120 89.010 E(21 '-1 211h/2 0.002764 1.301 22 -3-0 568.19 8.2490 24-1 % 0.067 22 -3'-O 8 (See Notes) 60'O 120 90.377 T(44'-7%) 4471/2 0.002545 27 -3'-0 568.19 8.3900 104-71/2 0.266 27 4-0 io (See Notes) 960'l1% 140 90.643 4EE(17'-6%), 5E(35'-l), 2T(79' -8%),_BFP(-8.795),_S 404-11% 1366-110.000672 1 4-0 568.19 10.4000 9.714 250.00 100.357 Hose Allowance At Source Total(Pt) Route 1 1 818.19 2955 12-71/2 8 26.86 1 (See Notes) 1'1% 120 11.272 Route 2 ..... Sprinkler, P0(5-10) 5. -'0 0.192239 0.480 1255 11'-6 26.86 1.0830 6 '- 11 Y2 1.336 13.089 Total(Pt) Route 2 2964 8'-6 8 26.95 1 (See Notes) 1,-U 120 11.350 ..... Route 3 ..... Sprinkler, E(2'-4) 2-4 0.193466 1274 8-6 26.95 1.0830 3-4 0.645 1274 8'-6 i (See Notes) 3'O 120 11.996 PO(5'-O) 1.301 1275 11'-6 26.95 1.0490 0.225979 :i8l'-00 1.808 12.503 Total(Pt) Route 3 2925 8'-6 8 30.96 1 (See Notes) 11-0 120 14.973 Route 4 ..... Sprinkler, E(2'-4) 2-4 0.249976 1114 8'-6 30.96 1.0830 3-4 0834 1114 8'-6 i (See Notes) 3'O 120 15.807 PO(5'-O) 5-0 0.291987 -1.301 1115 11-6 30.96 1.0490 8-0 2.336 16.843 Total(Pt) Route 4 , © M.E.P.CAD AutoSPRlNK 2023 v18.1 .38.0 1 5/17/2024 8:27:21AM Page 11 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 2894 12-7% 8 34.42 i (See Notes) 1-1% 120 18.510 Route5 ..... Sprinkler, P0(5-10) 5'10 0.304150 0.480 1065 11-6 34.42 1.0830 6-11 1/2 2.113 21.104 Total(Pt) Route 5 2972 1271/2 8 39.09 1 (See Notes) 1-1% 120 23.881 Route 6 ..... Sprinkler, P0(5-10) 5'-10 0.384965 0.480 1286 11-6 39.09 1.0830 6111/2 2.675 1286 11'-6 8-0 120 27.036 0.095477 1256 11-6 39.09 1.4420 8-0 0.764 1256 11-6 39.66 Vi 17-0 120 27.800 Flow (q) from Route 8 0.348792 1066 11-6 78.75 1.4420 17-0 5.929 1066 11-6 43.78 11/4 8-0 120 33.729 Flow (q) from Route 12 0.790238 959 11-6 122.53 1.4420 8-0 6.322 959 11-6 47.79 11/4 (See Notes) 6'g% 120 40.051 Flow (q) from Route 14 E(3'-8%), PO(T-5) 11-2 1.453331 -0.650 906 13'-0 170.33 1.4420 17-11% 26.084 906 13-0 4 12'-1 O% 120 65.485 0.007025 12'-10Y2 0.091 903 13-0 170.33 4.3100 65.576 Total(Pt) Route 6 2970 12-7% 8 39.28 1 (See Notes) 1'-l% 120 24.104 Route7 ..... Sprinkler, po(5'10) 51-10 0.388293 0.480 1284 11-6 39.28 1.0830 6-11% 2.698 1284 11-6 8-0 120 27.282 0.096303 1254 11-6 39.28 1.4420 8-0 0.770 1254 11-6 39.84 11h 17'-0 120 28.053 Flow (q) from Route 9 0.351804 1064 11-6 79.12 1.4420 17'-O 5.981 , © M.E.P.CAD AutoSPRINK 2023 v18.1.38. 0 1 5/17/2024 8:27:21AM Page 12 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 1064 11'-6 43.98 8'-0 120 34.034 Flow (q) from Route 13 0.797033 957 11-6 123.10 1.4420 8-0 6.376 957 11'-6 48.01 (See Notes) 6'9y2 120 40.410 Flow (q) from Route 15 E(3'-8%), PO(7'-5) 11'-2 -0.650 900 13-0 171.11 1.4420 1.465763 :17':ll% 26.307 66.067 Total(Pt) Route 7 2956 12-7% 8 39.66 1 (See Notes) 1 120 24.573 "•• Route 8•"•• Sprinkler, P0(5'-1 0) 5'-10 1 0.395275 0.480 1256 11-6 39.66 1.0830 6-11% 2.747 27.800 Total(Pt) Route 8 2954 12-7% 8 39.84 i (See Notes) 1-1% 1 120 24.802 Route ..... Sprinkler, P0(5-10) -10 0.398686 0.480 1254 11-6 39.84 1.0830 611h/2 2.770 28.053 Total(Pt) Route 9 2855 8'-6 8 40.28 1 (See Notes) 1-0 120 25.357 Route 10 ..... Sprinkler, E(2'-4) 2-4 0.406923 960 8'-6 40.28 1.0830 3-4 1.358 960 8'-6 i (See Notes) 3'O 120 26.714 PO(5'-O) 5'-O 0.475310 -1.301 961 11-6 40.28 1.0490 8-0 3.802 29.216 Total(Pt) Route 10 2853 12-7% 8 41.28 1 (See Notes) 1'-l% J 120 26.628 Route 11 ..... Sprinkler, P0(5'10) 5. -10 I 0.425760 0.480 958 11-6 41.28 1.0830 6-11% 2.958 30.067 Total(Pt) Route 11 2895 12-7% 8 43.78 1 (See Notes) 1-1% 120 29.950 ••••• Route 12 ..... Sprinkler, P0(5-10) 5-10 I 0.474682 0.480 1066 11'-6 43.78 1.0830 6-11% 3.298 33.729 Total(Pt) Route 12 2893 12-7% 8 43.98 1 (See Notes) 11-1% 120 30.227 ••". Route 13 ..... Sprinkler, PO(5'-10) 5'10 0.478729 6-11%3.326 0.480 1064 11'-6 43.98 1.0830 , © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 13 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: I Date: 5/17/2024 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added when directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 34.034 Total(Pt) Route 13 2854 12-7% 8 47.79 1 (See Notes) I 111/2 120 35.692 Route 14 Sprinkler, PO(5'-lO) 5-10 0.558279 0.480 959 11-6 47.79 1.0830 6 -11% 3.879 40.051 Total(Pt) Route 14 2852 12-7% 8 48.01 1 (See Notes) 1 1-1% 120 36.017 ..... Route 15 Sprinkler, P0(5-10) 5-10 0.562993 0.480 957 11-6 48.01 1.0830 6-11% 3.912 40.410 Total(Pt) Route 15 870 39-6 487.10 6 8'-9% 120 69.802 Route 16 Flow (q) from Route 1 0.000268 -0.000 819 39-6 81.09 6.3570 8'-9% 0.002 819 39-6 6 9-8 120 69.804 0.000203 765 39-6 69.68 6.3570 9-8 0.002 765 39-6 6 9-8 120 69.806 0.000150 711 39'-6 59.24 6.3570 9-8 0.001 711 39-6 6 9-8 120 69.807 0.000108 639 39'-6 49.56 6.3570 9-8 0.001 639 39'-6 6 9'-8 120 69.809 0.000074 562 39'-6 40.47 6.3570 9-8 0.001 562 39'-6 6 9-8 120 69.809 0.000047 508 39'-6 31.80 6.3570 9-8 0.000 508 39-6 6 9'-8 120 69.810 0.000027 443 39-6 23.41 6.3570 9-8 0.000 443 39-6 6 (See Notes) 91 8 120 69.810 P0(37-8%) 37'-8% 0.000012 188 39'-6 15.18 6.3570 47'-4% 0.001 © M.E.P.CAD jAutoSPRlNK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 14 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: I Date: 5/17/2024 Pipe Information Node 1 El v1 (Foot) K-Factor Flow added this step Nominal ID Fittings & Devices Equiv. Length Length (Foot) C t Factor Total(Pt) Notes Fitting/Device (Equivalent Fixed Pressure Losses, when applicable, are added directly to (N) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total Friction(Pf 188 39-6 6 (See Notes) 9-8 120 69.811 PO(37-8'/2) P0(37-81/2) 75'51/ 0.000003 101 39'-6 7.45 6.3570 8511/2 0.000 101 39'-6 21/2 (See Notes) 171-5 120 69.811 2T(18'-8%), 4E(9'-4%), P0(18'- 81/2) 0.000208 128 39-6 7.45 2.7050 265'-01h 0.055 128 39'-6 4 8-2 120 69.866 0.000023 192 39'-6 7.45 4.2600 8-2 0.000 192 39-6 7.73 9-8 120 69.866 Flow (q) from Route 18 0.000085 445 39'-6 15.18 4.2600 9-8 0.001 445 39'-6 8.23 4 9'-8 120 69. 867 Flow (q) from Route 19 0.000189 510 39'-6 23.41 4.2600 9-8 0.002 510 39'6 8.39 4 9-8 120 69.869 Flow (q) from Route 33 0.000333 564 39'-6 31.80 4.2600 9-8 0.003 564 39'-6 8.67 4 9-8 120 69. 872 Flow (q) from Route 36 0.000521 641 39-6 40.47 4.2600 9-8 0.005 641 39-6 9.09 4 9-8 120 69.877 Flow (q) from Route 32 0.000758 713 39-6 49.56 4.2600 9-8 0.007 713 39'6 9.68 9-8 120 69.884 Flow (q) from Route 27 0.001054 767 39-6 59.24 4.2600 9'-8 0.010 767 39'6 10.44 4 9-8 120 69. 895 Flow (q) from Route 30 0.001423 821 39'-6 69.68 4.2600 9-8 0.014 821 39-6 11.41 4 9-8 120 69. 908 Flow (q) from Route 24 =91-80 .001884 920 39-6 81.09 4.2600 0.018 © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 15 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) (psi) directly to (Pf) and shown as ( 920 39-6 12.22 4 9-8 120 69.926 Flow (q) from Route 28 0.002442 979 39-6 93.30 4.2600 9-8 0.024 979 39-6 9.46 4 10-0 120 69.950 Flow (q) from Route 31 0.002920 1128 39'-6 102.76 4.2600 10-0 0.029 1128 39-6 6.32 4 9-8 120 69.979 Flow (q) from Route 25 0.003260 1217 39-6 109.08 4.2600 9-8 0.032 1217 39-6 1.47 4 9-6 120 70.011 Flow (q) from Route 29 0.003342 1304 39-6 110.55 4.2600 9-6 0.032 1304 39'-6 21/2 (See 153-3 120 70.043 P0(18-8%) 74101/2 Notes) 1302 39-6 5.66 2.7050 0.000125 2T(18'-8%), P0(18-81/2) 228-1% 0.028 70.071 Total(Pt) Route 16 2479 39-6 32.88 6 (See 2'-8% 1 120 70.831 Route 17 ..... Flow (q) from Route 21 378Y Notes) 2467 39-6 32.88 6.3570 0.000050 P0(37-8%) 40-5 0.002 70.833 Total(Pt) Route 17 188 39-6 7.45 21/2 (See 156-6 120 69.811 Route 18 ..... Flow (q) from Route 16 Notes) 192 39-6 7.73 2.7050 0.000222 2T(18-8%), 4E(9'-4%), P0(18- 250'-1 0.056 8%) 69.866 Total(Pt) Route 18 443 39-6 21/2 (See 153-3 I 120 69.810 Route 19 ..... P0(18-8%) 74101/2 I Notes) 445 39-6 8.23 2.7050 I 0.000250 2T(18'-8%), P0(18-8%) 228-11/2 0.057 69.867 Total(Pt) Route 19 2292 39-6 52.95 21/2 (See 153-3 T 120 70.141 Route 20 ..... Notes) PO(18'-8%), Flow (q) from Route 34 7410% 2290 39-6 20.07 2.7050 0.001299 2T(18'-8%), P0(18-8%) ______________ 228-1% 0.296 70.437 Total(Pt) Route 20 © M.E.P.CAD JAutoSPRINK 2023 v1 8.1.38.0 1 5/17/2024 8:27:21AM Page 16 Job lame: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pt Friction Elev(Pe) Loss Per Unit (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow when applicable, are added Total Frictlon(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) fljfiy 2292 39'-6 52.95 4 (See 10'-o 120 70.141 Route 21 ..... Flow (q) from Route 34 26'-4 Notes) 2481 39-6 32.88 4.2600 0.000355 PO(26'-4) 36-4 0.013 2481 39'-6 21/2 (See 153'3 120 70.153 56'-2 Notes) 2479 39-6 32.88 2.7050 0.003238 2T(18'-8%), P0(18-8%) 9- 205 0.678 70.831 Total(Pt) Route 21 1514 39'-6 96.16 21/2 (See J 153'-3 120 70.097 Route 22 ..... Notes) P0(18-8%), Flow (q) from Route 37 74101/ ______________ 1512 39'-6 11.61 2.7050 0.000472 2T(18'-8%), P0(18-8%) 228'-l% 0.108 70.205 Total(Pt) Route 22 101-0 120 70.097 ..... Route 23 ..... 1514 39'-6 96.16 4 Flow (q) from Route 37 0.002035 1622 39-6 84.55 4.2600 10-0 0.020 1622 39'-6 2% (See 153'3 120 70.118 P0(18-8%) 74-10% Notes) 1620 39-6 14.40 2.7050 0.000703 2T(18-8%), P0(18-8%) 228'-11/2 0.160 70.278 Total(Pt) Route 23 819 39'-6 2% (See 153'-3 120 69.804 ..... Route 24 ..... P0(18-8%) 74101,4 Notes) 821 39'-6 11.41 2.7050 0.000457 2T(18'-8%), P0(18-8%) 228'-l% 0.104 69.908 Total(Pt) Route 24 1126 39'-6 2% (See 153'-3 J 120 69.944 Route 25 ..... P0(18-8%) 74-10% Notes) 1128 39'-6 6.32 2.7050 0.000153 2T(18'-8%), P0(18-8%) 228-11/2 0.035 69.979 Total(Pt) Route 25 9-6 120 70.043 Route 26 ..... 1304 39-6 5.66 4 Flow (q) from Route 16 0.003033 1397 39'-6 104.90 4.2600 9-6 0.029 1397 39'-6 21/2 (See 153'3 120 70.071 P0(18-8%) 74'-1O % Notes) 1395 39'-6 8.74 2.7050 0.000279 2T(18'-8%), P0(18-8%) 228'-l% 0.064 70.135 Total(Pt) Route 26 , © M.E.P.CAD jfj AutoSPRINK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 17 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fitting & s s Device Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 711 39'-6 2% (See Notes) 153'-3 120 69.807 Route 27 ..... P0(18-8%) 2T(18-8%), P0(18-8%) 74101/2 1 0.000337 713 39-6 9.68 2.7050 228'-11/2 0.077 69.884 Total(Pt) Route 27 918 39-6 2% (See Notes) 153'-3 T 120 69.808 Route 28••••• P0(18-8%) 2T(18'-81/.), P0(18-8%) 74-10% 1 0.000519 920 39-6 12.22 2.7050 228'-l% 0.118 69.926 Total(Pt) Route 28 1215 39-6 2% (See Notes) 153'-3 T 120 70.008 Route 29 ..... P0(18-8%) 2T(18-8%), P0(18-8%) 0.000010 74'74'-101/2 1217 39-6 1.47 2.7050 228'-11/2 0.002 70.011 Total(Pt) Route 29 765 39'-6 21/2 (See Notes) 153-3 J 120 69.806 ..... Route 3O ..... P0(18-8%) 2T(18'-81/2), P0(18-8%) 74101/2 0.000388 767 39-6 10.44 2.7050 228-11/2 0.088 69.895 Total(Pt) Route 30 977 39-6 21/2 (See Notes) 153'-3 1 120 69.876 Route 31 ..... P0(18-8%) 2T(18-8Y2), P0(18-8%) 74-10% t 0.000323 979 39-6 9.46 2.7050 228-1 1/; 0.074 69.950 Total(Pt) Route 31 639 39-6 21/2 (See Notes) 153-3 1 120 69.809 Route 32 ..... P0(18-8%) 2T(18-8%), P0(18-8%) 74-10% 0.000300 641 39-6 9.09 2.7050 228-1% 0.068 69.877 Total(Pt) Route 32 508 39-6 2% (See Notes) 153-3 1 120 69.810 Route 33 ..... P0(18-8%) 2T(18'-81/.), P0(18-8%) 74-10% 1 0.000259 510 39-6 8.39 2.7050 228-11/2 0.059 69.869 Total(Pt) Route 33 1622 39-6 14.40 4 101-0 120 70.118 Route 34..... Flow (q) from Route 23 0.001441 1961 39-6 70.15 4.2600 10-0 0.014 f©M.E.P.CAD ijijAutoSPRINK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 18 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PU and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) Friction(Pf) 1961 39'-6 4 T 10'-O 120 70.132 1 0.000856 2292 39-6 52.95 4.2600 1O'-O 0.009 70.141 Total(Pt) Route 34 1961 39 -6 21/2 (See Notes) 153'-3 120 70.132 ••••• Route 35•"•• P0(18-8%) 2T(18'-8%), P0(1 8'-8/2) 74'-1 O% 0.000977 1959 39'-6 17.21 2.7050 228-1% 0.223 70.355 Total(Pt) Route 35 562 39'-6 21/2 (See Notes) 153-3 120 69.809 .•• Route 36 ..... 2T(18'-8%), P0(18-8%) 0.000275 7474'-10Y2 P0(18-8%) 564 39-6 8.67 2.7050 228'-l% 0.063 69.872 Total(Pt) Route 36 1397 39'-6 8.74 101-0 120 70.071 Route 37 ..... Flow (q) from Route 26 0.002582 1514 39'-6 96.16 4.2600 10'-O 0.026 70.097 Total(Pt) Route 37 © M.E.P.CAD AutoSPRINK 2023 v18. 1.38.0 1 5/17/2024 8:27:21AM Page 19 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 1 Date: 5/17/2024 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) LC Value Multiplier • Actual Inside Diameter 4.87 Value Of C 100 130 140 150 I \ =Factor Schedule 40 Steel Pipe Inside Diameter ) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22h/2 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , 0 M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 1 5/17/2024 8:27:21AM Page 20 Hydraulic Calculations for Project Name: RACEWAY UPS CONVEYORS: (SD0269) Location: 3125 LIONSHEAD AVE, CARLSBAD, CA. 92008, Drawing Name: 5D0269 RACEWAY CONVEYORS Design Remote Area Number: 2 Occupancy Classification: Ordinary Group II Commodity Classification: O.H. Density 0.20gpm/ft2 Area of Application: 1500ft2 (Actual 1519ft2) Coverage per Sprinkler: 130ft2 Type of sprinklers calculated: Upright No. of sprinklers calculated: 24 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 1 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 993.43 @ 72.308 Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherAgent System: Calculation Date: 5/17/2024 Allowance at Source (Safety Margin = 48.003) N/A Name of Contractor: Hiller Fire Address: 7130 CONVOY CT, SAN DIEGO, CA. 92111 Phone Number: 858-277-3473 Name of designer: BEN LEDESMA Authority Having Jurisdiction: : CARLSBAD Notes: Automatic peaking results Left: N/A Right: N/A (1A© M.E.P.CAD AutoSPRlNK 2023 08.1.38.0 2 5/17/2024 8:28:03AM Page 1 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 150- 135 120 105 45 3C it - Supply Summary Sheet Node:1 -- Static Pressure 120.600 993.43©120.311—...... - - S 10001.00 - c - - 993.43 743.43 with Hose 72.308 Allowance at Source- S stem demand curve ...Lr'iuiLLlIIIIIII 111111111 111111111 111111111 I II liii liii I I I I I I I I I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 5/17/2024 4600 6900 UZLAJ 5750 8050 10350 Flow - gpm Supply:static:120.600 Residual :99.900 Flowing: 10001.00 Available Flow @ 20 PSI:23486.72 .,© M.E.P.CAD '! I I AutoSPRINK 2023 v18.1.38.0 5/17/2024 8:28:05AM Paqe 2 1111 Summary Of Outfiowing Devices Job Number: SD0269 Report Description: Ordinary Group 11 (2) Device Actual Flow (gpm) Minimum Flow (gpm) K.Factor (K) Pressure (psi) Sprinkler 3057 3361 26.00 8 17.655 Sprinkler 3058 33.25 26.00 8 17.272 Sprinkler 3059 33.15 26.00 8 17.166 Sprinkler 3092 31.86 26.00 8 15.858 Sprinkler 3093 31.51 26.00 8 15.512 Sprinkler 3094 31.41 26.00 8 15.417 Sprinkler 3136 32.19 26.00 8 16.192 Sprinkler 3137 31.77 26.00 8 15.767 Sprinkler 3138 31.84 26.00 8 15.839 Sprinkler 3139 31.44 26.00 8 15.442 Sprinkler 3140 31.74 26.00 8 15.741 Sprinkler 3141 31.35 26.00 8 15.353 Sprinkler 3179 32.47 26.00 8 16.477 Sprinkler 3180 32.12 26.00 8 16.119 Sprinkler 3181 32.02 26.00 8 16.019 Sprinkler 3208 26.34 26.00 8 10.842 Sprinkler 3209 26.07 26.00 8 10.623 C:> Sprinkler 3210 26.00 26.00 8 10.563 Sprinkler 3242 35.03 26.00 8 19.170 Sprinkler 3243 34.65 26.00 8 18.757 Sprinkler 3244 34.54 26.00 8 18.643 Sprinkler 3279 26.55 26.00 8 11.015 Sprinkler 3280 26.30 26.00 8 10.806 Sprinkler 3281 26.23 26.00 8 10.749 c> Most Demanding Sprinkler Data , © M.E.P.CAD III AutoSPRlNK 2023 v18.1.38.0 5/17/2024 8:28:06AM Page 3 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 120.600 99.900 10001.00 120.311 993.43 72.308 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 717 39-6 39.110 721 39'-6 39.417 771 39'-6 39.069 773 39-6 39.422 825 39'-6 39.012 827 39'-6 39.430 924 39-6 38.938 926 39-6 39.441 983 39'-6 38.842 985 39'-6 39.455 1132 39'-6 38.713 1134 39'-6 39.473 1221 39'-6 38.552 1223 39'-6 39.496 1308 39'-6 38.351 1310 39'-6 39.525 1401 39-6 38.093 1403 39-6 39.561 (è&© M.E.P.CAD AutoSPRINK 2023 v18.1.38. 5/17/2024 8:28:09AM Pate 4 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1518 39-6 37.749 1520 39-6 39.610 1588 11-6 21.529 1589 11'-6 21.095 1590 11'-6 20.975 1625 39'-6 37.311 1627 39-6 39.673 1693 11-6 21.571 1696 11-6 21.135 1699 11-6 21.015 1809 11-6 21.728 1810 13'-6 18.803 1811 11-6 21.290 1812 13-6 18.404 1813 11-6 21.168 1814 13-6 18.293 1924 11-6 21.793 1925 14-0 18.468 1926 11-6 21.354 1927 14-0 18.074 1928 11-6 21.232 1929 14'-0 17.965 © M.E.P.CAD MINAUtOSPRINK 2023 v18.1.38. 5/17/2024 8:28:09AM Page 5 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1965 39'-6 36.751 1967 39-6 39.752 2034 11-6 22.348 2037 11-6 21.898 2040 11-6 21.773 2145 11'-6 22.893 2149 11-6 22.432 2153 11-6 22.304 2219 7101/2 12.768 2220 7101/2 12.518 2221 7-10% 12.449 2251 11'-6 23.248 2252 11-6 22.779 2253 11-6 22.650 2296 39-6 36.039 2298 39'-6 39.854 2410 39-6 35.855 2423 11-6 28.139 2425 13-0 33.367 2426 11-6 27.575 2428 13-0 32.688 2429 11-6 27.419 (,© M.E.P.CAD AutoSPRINK 2023 v18.1.38. 5/17/2024 8:28:09AM Paqe 6 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 2431 13'-0 32.501 2479 39'-6 63.608 2485 39-6 35.928 2487 39-6 39.982 2559 0-0 63.608 2564 0-0 59.066 2569 13-0 58.617 1 -3-0 Supply 72.308 743.43 3057 14'-6 Sprinkler 17.655 33.61 3058 14-6 Sprinkler 17.272 33.25 3059 14-6 Sprinkler 17.166 33.15 3092 14-6 Sprinkler 15.858 31.86 3093 14-6 Sprinkler 15.512 31.51 3094 14-6 Sprinkler 15.417 31.41 3136 14-6 Sprinkler 16.192 32.19 3137 11'-6 Sprinkler 15.767 31.77 3138 14'-6 Sprinkler 15.839 31.84 3139 11-6 Sprinkler 15.442 31.44 3140 14'-6 Sprinkler 15.741 31.74 3141 11'-6 Sprinkler 15.353 31.35 3179 14'-6 Sprinkler 16.477 32.47 3180 14-6 Sprinkler 16.119 32.12 1&©M.E.P.CAD jAutoSPRlNK2023v18.1.38. 5/17/2024 8:28:09AM Paqe7 Job Nanie: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 3181 14-6 Sprinkler 16.019 32.02 3208 8-6 Sprinkler 10.842 26.34 3209 8-6 Sprinkler 10.623 26.07 3210 8-6 Sprinkler 10.563 26.00 3242 14'-6 Sprinkler 19.170 35.03 3243 14'-6 Sprinkler 18.757 34.65 3244 14-6 Sprinkler 18.643 34.54 3279 6-6 Sprinkler 11.015 26.55 3280 6-6 Sprinkler 10.806 26.30 3281 6-6 Sprinkler 10.749 26.23 22 -3'-0 63.608 - 23 -3-0 60.477 24 -3'-0 61.573 27 -3-0 63.608 30 -3-0 61.033 31 -3-0 61.573 105 39'-6 39.203 107 39-6 39.406 196 39'-6 39.197 198 39-6 39.406 449 39-6 39.183 451 39-6 39.406 ,©M.E.P.CAD JAutoSPRlNK 2023 v18.1.38. 5/17/2024 8:28:09AM Paqe8 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 514 39'-6 39.175 516 39-6 39.407 568 39-6 39.161 570 39-6 39.409 645 39-6 39.140 648 39-6 39.412 .,© M.E.P.CAD i1 AutoSPRINK 2023 v18.1.38. 5/17/2024 8:28:09AM Page 9 Job Name: RCEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 3210 8'-6 8 26.00 1 (See Notes) 3-1 120 10.563 Route I ..... Sprinkler, T(5'-1 0) 5-10 0.181014 0.274 2221 7'-10'A 26.00 1.0830 8-11 1.612 2221 7'-10% 26.23 1 (See Notes) 4-6% 120 12.449 Flow (q) from Route 3 3E(2-4), P0(5-10) 12-10 0.657864 -1.575 2153 11-6 52.23 1.0830 17-4 % 11.430 2153 11-6 159.66 2 1-3 120 ____ 22.304 ______ Flow (q) from Route 7 0.276363 2253 11-6 211.89 2.2030 1-3 0.346 2253 11'-6 34.54 2 (See Notes) 6'-3 120 22.650 Flow (q) from Route 22 E(6'-1 0) 6'-10 0.365438 2429 11'-6 246.43 2.2030 13-0% 4.770 2429 11'-6 2 (See Notes) 1-6 120 27.419 P0(10-0) 101-0 0.498409 -0.650 2431 13'-0 246.43 2.0670 11'-6 5.732 2431 13'-0 4 13'-6 120 32.501 0.013912 2428 13-0 246.43 4.3100 13-6 0.188 2428 13'-0 247.17 4 13-6 120 32.688 Flow (q) from Route 2 0.050292 2425 13-0 493.60 4.3100 13'-6 0.679 2425 13-0 249.82 4 (See Notes) 88'5% 120 33.367 Flow (q) from Route 5 E(13-11), PO(27'-10%) 1 4-9% 0.107285 -11.488 2410 39'-6 743.43 4.3100 130-3 13.976 2410 39'-6 4 (See Notes) 7'11% 120 35.855 P0(26-4) 26'-4 0.002115 2485 39-6 86.34 4.2600 34-3% 0.073 2485 39-6 2% (See Notes) 153'g 120 35.928 2T(18'-8%), P0(18-8%) 56'-2 0.019318 2487 39-6 86.34 2.7050 209'-11 4.055 2487 39-6 657.09 6 (See Notes) 86'O% 120 39.982 Flow (q) from Route 25 2E(17-7) 35-2% 0.016166 17.124 2564 01-0 743.43 6.3570 121-2% 1.960 © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 10 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev, I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 2564 01-0 8 (See Notes) 30 120 59.066 E(21'-11/2) 211h/z 0.004545 1.301 23 -3'-0 743.43 8.2490 24'-l% 0.110 23 -3-0 8 (See Notes) 88'2 120 60.477 T(44'-7%) 4471/2 0.004185 30 -3-0 743.43 8.3900 132-10 0.556 30 -3-0 10 488-8 140 61.033 0.001106 31 4-0 743.43 10.4000 488'-8 0.540 31 4-0 10 (See Notes) 1951'5 140 61.573 6E(35-1), 2T(79'-81/2), BFP(-8. 169),S 369-laY2 0.001106 1 -3-0 743.43 10.4000 2321 31/2 10.735 250.00 72.308 Hose Allowance At Source Total(Pt) Route 1 1 993.43 3209 8-6 8 26.07 1 (See Notes) 3-1 120 10.623 Route 2 ..... Sprinkler, T(5'-1 0) 1.621 5-10 0.181973 0.274 2220 7-10% 26.07 1.0830 8-11 2220 7-10% 26.30 1 (See Notes) 4'6% 120 12.518 Flow (q) from Route 4 3E(2'-4), P0(5-10) 12-10 0.661237 -1.575 2149 11-6 52.37 1.0830 17'-4/2 11.488 2149 11-6 160.15 2 1-3 120 22.432 Flow (q) from Route 9 0.277891 2252 11'-6 212.52 2.2030 1-3 0.348 2252 11'-6 34.65 2 (See Notes) 63 120 22.779 Flow (q) from Route 23 E(6'-10) 6-10 0.367466 2426 11-6 247.17 2.2030 4.796 2426 11-6 2 (See Notes) 1'6 120 27.575 P0(10-0) 101-0 0.501175 -0.650 2428 13-0 247.17 2.0670 11'-6 5.764 32.688 Total(Pt) Route 2 (,©M.E.P.CAD jAutoSPRlNK 2023 08.1.38.0 2 5/17/2024 8:28:12AM Page 11 Job Name: RCEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Elev i Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) Loss Per unit (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pt) and shown as (Foot) 3281 6'-6 8 26.23 i (See 671/2 1 120 10.749 Route ..... Sprinkler, 5'-10 -0.593 Notes) 2221 710h/2 26.23 1.0830 0.183964 T(5'-1 0) 12'- 51/2 2.293 12.449 Total(Pt) Route 3 3280 6-6 8 26.30 1 (See 671/2 120 10.806 .•" Route 4 ..... Sprinkler, 5'-10 -0.593 Notes) 2220 7-101/2 26.30 1.0830 0.184877 T(5'-10) 12'-5% 2.305 12.518 Total(Pt) Route 3208 8'-6 8 26.34 1 (See 3-1 120 10.842 Route ..... Sprinkler, 5'-10 0.274 Notes) 2219 7-10% 26.34 1.0830 0.185438 T(5'-1 0) 8-11 1.652 2219 7-10% 26.55 1 (See 4'6% 120 12.768 Flow (q) from Route 6 12'-10 -1.575 Notes) 2145 11'-6 52.89 1.0830 0.673429 3E(2'-4), P0(5-10) 17-4% 11.700 2145 11-6 161.90 2 1-3 120 22.893 Flow (q) from Route 12 0.283413 2251 11'-6 214.80 2.2030 1-3 0.355 2251 11'-6 35.03 2 (See 6'-3 120 23.248 Flow (q) from Route 24 6'-10 Notes) 2423 11-6 249.82 2.2030 0.374792 E(6'- 10) 13-0% 4.892 2423 11-6 2 (See 1'6 120 28.139 101-0 -0.650 Notes) 2425 13-0 249.82 2.0670 0.511167 PO(10'-O) 11'-6 5.878 33.367 Total(Pt) Route 5 3279 6'-6 8 26.55 1 (See 6'7% 120 11.015 Route 6 • Sprinkler, 5'-10 -0.593 Notes) 2219 7'-10% 26.55 1.0830 0.188175 T(5'-10) 12-5% 2.346 12.768 Total(Pt) Route 6 3141 11'-6 8 31.35 1 (See 8'-9 120 15.353 Route ..... Sprinkler, 4-0 -0.868 Notes) 1814 13-6 31.35 1.0490 0.298822 2E(2'-O) 12'-g 3.809 , © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 12 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 1814 13-6 i Notes) 2-0 (See 120 18.293 P0(5-10) 51 10 T-100.255828 0.868 1813 11'-6 31.35 1.0830 2.007 1813 11-6 64.56 2 1-0 120 21.168 Flow (q) from Route 8 0.063762 1928 11-6 95.90 2.2030 1-0 0.064 1928 11'-6 31.74 2 5-0 120 21.232 Flow (q) from Route 11 0.108210 2040 11-6 127.64 2.2030 5-0 0.541 2040 11'-6 32.02 2 3-3 120 21.773 Flow (q) from Route 15 0.163719 2153 11-6 159.66 2.2030 3-3 0.531 22.304 Total(Pt) Route 7 3094 14-6 8 31.41 1 (See Notes) 6-2% 120 15.417 "•• Route 8 Sprinkler, 2E(2'-4), PO(5'-10) 10-6 0.256813 1.301 1699 11-6 31.41 1.0830 16-9 4.298 1699 11-6 33.15 2 5-0 120 21.015 Flow (q) from Route 19 0.030660 1813 11-6 64.56 2.2030 5-0 0.153 21.168 Total(Pt) Route 8 3139 11-6 8 31.44 1 (See Notes) 8-9 120 15.442 Route 9..... Sprinkler, 2E(2-0) 4-0 0.300438 -0.868 1812 13-6 31.44 1.0490 12'-g 3.830 1812 13-6 1 (See Notes) 2-0 120 18.404 P0(5-10) 5-10 0.257211 0.868 1811 11-6 31.44 1.0830 7-10 2.017 1811 11-6 64.76 2 11-0 120 21.290 Flow (q) from Route 10 0.064120 1926 11-6 96.19 2.2030 1-0 0.064 1926 11-6 31.84 2 5-0 120 21.354 Flow (q) from Route 13 0.108821 2037 11'-6 128.03 2.2030 5-0 0.544 (,© M.E.P.CAD r.11 2023 v1 8.1.38.0 2 5/17/2024 8:28:12AM Page 13 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev i (Foot) K.Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 2037 11-6 32.12 2 J 3-3 120 21.898 Flow (q) from Route 16 0.164646 2149 11'-6 160.15 2.2030 3-3 0.534 22.432 Total(Pt) Route 9 3093 14'-6 8 31.51 i (See Notes) 6-2% 120 15.512 Route 10 ..... Sprinkler, 2E(2'-4), PO(5'-10) 10'-6 0.258287 1.301 1696 11'-6 31.51 1.0830 16-9 4.323 1696 11'-6 33.25 2 5-0 120 21.135 Flow (q) from Route 20 0.030835 1811 11-6 64.76 2.2030 5'-O 0.154 21.290 Total(Pt) Route 10 3140 14-6 8 31.74 1 (See Notes) 2-61/2 120 15.741 Route II ..... Sprinkler, 2E(2'-O) 4-0 0.305813 0.217 1929 14-0 31.74 1.0490 6-6% 2.007 1929 14'-0 I (See Notes) 2'6 120 17.965 P0(5-10) 5-10 0.261813 1.084 1928 11'-6 31.74 1.0830 8-4 2.184 21.232 Total(Pt) Route 11 3137 11-6 8 31.77 1 (See Notes) 8-9 120 15.767 Route 12 ..... Sprinkler, 2E(2'-O) 4-0 0.306276 -0.868 1810 13'-6 31.77 1.0490 12'-9 3.904 1810 13'-6 i (See Notes) 2'O 120 18.803 P0(5-10) 5'-10 0.262210 T-10 2.057 0.868 1809 11'-6 31.77 1.0830 1809 11'-6 65.47 2 1-0 120 21.728 Flow (q) from Route 14 0.065414 1924 11'-6 97.24 2.2030 1-0 0.065 1924 11-6 32.19 2 5-0 120 21.793 Flow (q) from Route 17 0.111029 2034 11-6 129.43 2.2030 5-0 0.555 2034 11-6 32.47 2 3-3 120 22.348 Flow (q) from Route 18 0.167995 2145 11'-6 161.90 2.2030 3-3 0.545 © M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 14 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev, i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as np+krn Fitting (Foot) Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot ) Friction(Pf) 22.893 Total(Pt) Route 12 3138 14-6 8 31.84 1 (See Notes) 26h/2 120 15.839 Route 13.".. Sprinkler, 2E(2'-O) 4-0 0.307566 0.217 1927 14'-0 31.84 1.0490 6'-6Y2 2.018 1927 14-0 1 (See Notes) 2'6 120 18.074 P0(5-10) 5-10 0.263314 1.084 1926 11-6 31.84 1.0830 8 -4 2.196 21.354 Total(Pt) Route 13 3092 14'-6 8 31.86 1 (See Notes) 6'2% 120 15.858 Route 14 ..... Sprinkler, 2E(2'-4), P0(6-10) 10-6 0.263612 1.301 1693 11'-6 31.86 1.0830 16-9 4.412 1693 11-6 33.61 2 5-0 120 21.571 Flow (q) from Route 21 0.031469 1809 11'-6 65.47 2.2030 5-0 0.157 21.728 Total(Pt) Route 14 3181 14'-6 8 32.02 1 (See Notes) 621/2 120 16.019 Route 15 ..... Sprinkler, 2E(2'-4), PO(5'-10) 10-6 0.266089 1.301 2040 11-6 32.02 1.0830 16-9 4.453 21.773 Total(Pt) Route 15 3180 14'-6 8 32.12 1 (See Notes) 6-2% 120 16.119 Route 16 ..... Sprinkler, 2E(2-4), P0(5-10) 10'-6 0.267612 1.301 2037 11-6 32.12 1.0830 16'-9 4.479 21.898 Total(Pt) Route 16 3136 14'-6 8 32.19 1 (See Notes) 2-6% 120 16.192 Route 17 ..... Sprinkler, 2E(2'-O) 4-0 0.313898 0.217 1925 14-0 32.19 1.0490 6-61/2 2.060 1925 14-0 1 (See Notes) 2-6 120 18.468 P0(5-10) 5-10 0.268735 1.084 1924 11'-6 32.19 1.0830 8-4 2.241 21.793 Total(Pt) Route 17 3179 14-6 8 32.47 1 (See Notes) 6'-21/2 1 120 16.477 T "" Route 18 ..... Sprinkler, 2E(2'-4), P0(5-10) 10-6 t 0.273114 1.301 I 2034 11-6 32.47 1.0830 16-9 4.571 (, © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 2 5117/2024 8:28:12AM Page 15 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as i9p" "al• Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) ________________ Friction(Pf) 22.348 J Total(Pt) Route 18 3059 14'-6 8 33.15 1 (See Notes) 3-0 120 17.166 Route 19 ..... Sprinkler, PQ(5'10) 5'-10 0.283667 1.301 1590 11'-6 33.15 1.0830 8-10 2.508 1590 11'-6 2 4-6 120 20.975 0.008932 1699 11'-6 33.15 2.2030 4-6 0.040 21.015 Total(Pt) Route 19 3058 14'-6 8 33.25 i (See Notes) 3-0 120 17.272 ..... Route 2O..... Sprinkler, PO(5'-10) 5'-10 0.285284 1.301 1589 11'-6 33.25 1.0830 8-10 2.522 1589 11-6 2 4-6 120 21.095 0.008983 1696 11'-6 33.25 2.2030 4'-6 0.040 21.135 Total(Pt) Route 20 3057 14'-6 8 33.61 1 (See Notes) 3'O 120 17.655 Route 21 ..... Sprinkler, P0(5-10) 5'-10 0.291126 1.301 1588 11'-6 33.61 1.0830 8-10 2.574 1588 11'-6 2 4'-6 120 21.529 0.009167 1693 11-6 33.61 2.2030 4'-6 0.041 21.571 Total(Pt) Route 21 3244 14-6 8 34.54 i (See Notes) 3-0 120 18.643 Route 22 ..... Sprinkler, PQ(5'..10) 5'-10 0.306159 1.301 2253 11-6 34.54 1.0830 8'-10 2.707 22.650 Total(Pt) Route 22 3243 14-6 8 34.65 1 (See Notes) J 3-0 120 18.757 Route 23 ..... Sprinkler, PO(5'-l0) 5'-10 0.307893 1.301 2252 11-6 34.65 1.0830 8'-10 2.722 22.779 Total(Pt) Route 23 3242 14-6 8 35.03 1 (See Notes) 3-0 120 19.170 ..... Route 24..... Sprinkler, P0(5'-1 0) 5-10 0.314159 1.301 2251 11-6 35.03 1.0830 I 8-10 2.777 f, © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 16 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as _____________ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 23.248 Total(Pt) Route 24 451 39-6 34.45 + 17.20 6 9-8 120 39.406 Route 25..... Flow (q) from Route 35 and 43 _______ 0.000116 _______________ 516 39-6 51.65 6.3570 __ 9-8 0.001 516 39'-6 17.57 6 9-8 120 39. 407 Flow (q) from Route 31 0.000200 570 39-6 69.22 6.3570 9-8 0.002 570 39-6 18.20 6 9-8 120 39. 409 Flow (q) from Route 29 0.000308 648 39-6 87.42 6.3570 9-8 0.003 648 39'-6 19.13 6 9-8 120 39. 412 Flow (q) from Route 48 0.000444 721 39'-6 106.55 6.3570 9-8 0.004 721 39'6 20.40 6 9-8 120 39. 417 Flow (q) from Route 30 0.000615 773 39-6 126.95 6.3570 9-8 0.006 773 39'-6 22.06 6 9-8 120 39. 422 Flow (q) from Route 33 0.000827 827 39-6 149.01 6.3570 9-8 0.008 827 39'-6 24.14 6 9-8 120 39. 430 Flow (q) from Route 34 0.001091 926 39'-6 173.15 6.3570 9-8 0.011 926 39'6 26.67 6 9-8 120 39. 441 Flow (q) from Route 32 0.001422 985 39'-6 199.83 6.3570 9-8 0.014 985 39'-6 29.69 6 10-0 120 39. 455 Flow (q) from Route 38 0.001838 1134 39-6 229.52 6.3570 10'-0 0.018 1134 39-6 33.36 6 9-8 120 39. 473 Flow (q) from Route 42 0.002362 9-8 1223 39-6 262.88 6.3570 0.023 1223 396 37.49 6 9-6 120 39. 496 Flow (q) from Route 28 0.003023 9 -6 1310 39-6 300.37 6.3570 0.029 ,©M.E.P.CAD JAutoSPRlNK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 17 Job Name: RA10EWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total when applicable, are added ________________ Friction(Pf) 1310 39'-6 42.19 6 9-6 120 39. 525 Flow (q) from Route 27 0.003855 1403 39'-6 342.56 6.3570 9-6 0.037 1403 39'-6 47.60 6 10-0 120 39.561 Flow (q) from Route 41 0.004905 1520 39-6 390.16 6.3570 10-0 0.049 1520 39'-6 54.13 6 101-0 120 39. 610 Flow (q) from Route 40 0.006237 1627 39-6 444.29 6.3570 101-0 0.062 1627 39'-6 62.97 6 101-0 120 39. 673 Flow (q) from Route 37 0.007970 1967 39-6 507.25 6.3570 10-0 0.080 1967 39-6 70.07 6 10-0 120 39. 752 Flow (q) from Route 36 0.010126 2298 39'-6 577.33 6.3570 10,-0 0.101 2298 39'-6 79.76 6 101-0 120 39. 854 Flow (q) from Route 26 0.012865 2487 39'-6 657.09 6.3570 10-0 0.129 39.982 Total(Pt) Route 25 2410 39'-6 86.34 20h/2 120 35.855 ••'• Route 26 ..... Flow (q) from Route I 0.090372 2296 39-6 657.09 4.2600 20h/2 0.184 2296 39-6 21/2 (See Notes) 153'-9 120 36.039 P0(18-81/2) 2T(18-8%), P0(18-8%) 74101/2 0.016684 2298 39-6 79.76 2.7050 22871/z 3.814 39.854 Total(Pt) Route 26 1308 39'-6 342.56 2% (See Notes) 153-9 1 120 38.351 Route 27 ..... P0(1 8'-81/2), Flow (q) from Route 45 2T(18'-8%), P0(18-8%) 74'- 101/2 I 0.005136 1310 39'-6 42.19 2.7050 22871,4 1.174 39.525 Total(Pt) Route 27 1308 39-6 342.56 4 9'-6 120 38.351 ••". Route 28..... Flow (q) from Route 45 0.021237 1221 39-6 300.37 4.2600 9'-6 0.202 ,©M.E.P.CAD ,11 AutoSPRlNK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 18 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) _____________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 1221 39-6 21/2 (See Notes) 153'9 120 38.552 P0(18-81/2) 2T(18'-8%), P0(18-81/2) 74101/2 0.004128 1223 39-6 37.49 2.7050 228-7% 0.944 39.496 Total(Pt) Route 28 771 39-6 4 9-8 120 39.069 "'" Route 29"" 0.004317 717 39-6 126.95 4.2600 9-8 0.042 717 39-6 4 9-8 120 39.110 0.003122 645 39-6 106.55 4.2600 9-8 0.030 645 39'-6 4 9-8 120 39.140 0.002165 568 39-6 87.42 4.2600 9-8 0.021 568 39-6 21/2 (See Notes) 153'-9 120 39.161 2T(18'-8%), P0(18-8%) 0.001084 74'-101/2 P0(1 570 39'-6 18.20 2.7050 228-7% 0.248 39.409 Total(Pt) Route 29 717 39-6 21/2 (See Notes) 153-9 120 39.110 "" Route 3O ..... P0(18-8%) 2T(18-8%), P0(18-8%) 741101/ 0.001340 721 39-6 20.40 2.7050 228-71/2 0.306 39.417 Total(Pt) Route 30 568 39'-6 18.20 4 9-8 120 39.161 Route 31 ..... Flow (q) from Route 29 0.001406 514 39-6 69.22 4.2600 9-8 0.014 514 39'-6 2% (See Notes) 153'9 120 39.175 P0(18-8%) 2T(18-8%), P0(18-8%) 7411/ 10 0.001016 516 39-6 17.57 2.7050 22871/2 0.232 39.407 Total(Pt) Route 31 924 39-6 199.83 21/2 (See Notes) 153-9 120 38.938 Route 32 ..... P0(1 8'-81/2), Flow (q) from Route 44 2T(18'-8%), P0(18-8%) 74101/2 0.002199 ____________ 926 39-6 26.67 2.7050 228-7 % 0.503 39.441 Total(Pt) Route 32 )4, © M.E.P.CAD r§1 AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 19 Job Name: RCEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Device s Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as np+i. Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 924 39'-6 199.83 4 9'8 120 38.938 Route 33 ..... Flow (q) from Route 44 0.007665 825 39'-6 173.15 4.2600 9-8 0.074 825 39'-6 4 9'-8 120 39.012 0.005806 771 39'-6 149.01 4.2600 9-8 0.056 771 39'-6 21/2 (See Notes) 153'9 120 39.069 P0(18-8%) 2T(188 '-1/2), P0(18-8%) 74101/2 773 39'-6 22.06 2.7050 -- r 0.001548 228-7% 0.354 39.422 Total(Pt) Route 33 825 39-6 2% (See Notes) J 153'-9 120 39.012 Route 34•"•• P0(18-8%) 2T(18'-8%), P0(18-81/2) 74101/2 0.001828 827 39'-6 24.14 2.7050 I 228-7% 0.418 39.430 Total(Pt) Route 34 196 39-6 4 (See Notes) 9-8 120 39.197 Route 35 ..... PO(26'-4) PO(26'-4) 52-8 0.000105 105 39-6 17.07 4.2600 62-4 0.007 105 39-6 2% (See Notes) 153'9 120 39.203 2T(18'-81/.), P0(18-8%) 56'-2 0.000963 107 39'-6 17.07 2.7050 209-11 0.202 107 39'-6 6 9-8 120 39.406 0.000015 198 39-6 17.07 6.3570 9-8 0.000 198 39-6 17.37 6 9-8 120 39.406 Flow (q) from Route 39 0.000055 451 39'-6 34.45 6.3570 9-8 0.001 39.406 Total(Pt) Route 35 1965 39'-6 577.33 2% (See Notes) 153-9 120 36.751 ..... Route 36 ..... Flow (q) from Route Route 47 21(18-8%), P0(18-8%) 74'-101/2 0.013130 ______________ 1967 39-6 70.07 2.7050 228'-7% 3.002 39.752 Total(Pt) Route 36 (,© M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 20 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pt Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total _________________ Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) *.1 101-0 120 36.751 Route 37 ..... 1965 39'-6 57733 4 Flow (q) from Route 47 0.055988 1625 39'-6 507.25 4.2600 10-0 0.560 1625 39'-6 21/2 (See 153'9 120 37.311 P0(18-8%) Notes) 1627 39-6 62.97 2.7050 0.010774 E(9'-4Y2), T(18-8%), P0(18-8 E23 2.362 1,) 39.673 Total(Pt) Route 37 1132 39-6 4 101-0 120 38.713 ..... Route 38•"• 0.012910 983 39-6 229.52 4.2600 10'-O 0.129 983 39-6 21/2 (See 153'9 120 38.842 P0(18-8%) 74-10% Notes) 985 39'-6 29.69 2.7050 0.002681 2T(18'-8%), P0(18-8%) 228-7% 0.613 39.455 Total(Pt) Route 38 449 39-6 4 (See 9-8 120 39.183 Route 39 ..... 26-4 Notes) 196 39'-6 34.45 4.2600 0.000386 PO(26'-4) 36'-0 0.014 196 39-6 17.07 21/2 (See 153'9 120 39.197 Flow (q) from Route 35 56'-2 Notes) 198 39-6 17.37 2.7050 0.000995 2T(18'-8%), P0(18-8%) 209-11 0.209 39.406 Total(Pt) Route 39 1518 39'-6 444.29 21/2 (See 1539 J 120 37.749 Route 40 ..... Notes) P0(18-8%), Flow (q) from Route 46 741O1/ 1 ______________ 1520 39-6 54.13 2.7050 0.008143 2T(18-8%), P0(18-8%) 228-7 % 1.862 39.610 Total(Pt) Route 40 1518 39-6 444.29 4 101-0 120 37.749 Route 41 ..... Flow (q) from Route 46 0.034453 1401 39-6 390.16 4.2600 10'-O 0.345 1401 39-6 21/2 (See 153-9 120 38.093 P0(18-8%) 74'-10'/2 Notes) 1403 39-6 47.60 2.7050 0.006422 2T(18'-8%), P0(18-8%) 228'-71/2 1.468 39.561 Total(Pt) Route 41 ©M.E.P.CAD AutoSPRlNK2O23v18.1.38.O 2 5/17/2024 8:28:12AM Page 21 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 1221 39'-6 3749 4 9-8 120 38.552 Route 42 ..... Flow (q) from Route 28 0.016595 1132 39'-6 262.88 4.2600 9-8 0.160 1132 39-6 21,4 (See Notes) 153'g 120 38.713 P0(18-8%) 2T(18'-8%), P0(18-8%) 74101,4 0.003326 1134 39'-6 33.36 2.7050 0.760 39.473 Total(Pt) Route 42 514 39-6 17.57 4 9'-8 120 39.175 ••••• Route 43•"•• Flow (q) from Route 31 0.000818 449 39-6 51.65 4.2600 9-8 0.008 449 39'-6 21,4 (See Notes) 153'9 120 39.183 P0(18-8%) 2T(18-8%), P0(18-8%) 74101/z 0.000977 451 39'-6 17.20 2.7050 228-7% 0.223 39.406 Total(Pt) Route 43 983 39-6 29.69 4 9-8 120 38.842 Route 44 ..... Flow (q) from Route 38 0.009992 924 39-6 199.83 4.2600 9-8 0.097 38.938 Total(Pt) Route 44 1401 39'-6 47.60 4 9-6 f 120 38.093 Route 45 ..... Flow (q) from Route 41 0.027082 1308 39'-6 342.56 4.2600 9-6 0.257 38.351 Total(Pt) Route 45 1625 39-6 62.97 4 10-0 I 120 37.311 Route 46 ..... Flow (q) from Route 37 0.043813 1518 39'-6 444.29 4.2600 10-0 0.438 37.749 Total(Pt) Route 46 2296 39'-6 79.76 4 101-0 I 120 36.039 ••"• Route 47 ..... Flow (q) from Route 26 0.071131 1965 39'-6 577.33 4.2600 1O'-O 0.711 36.751 Total(Pt) Route 47 645 39-6 2% (See Notes) 153'-9 1 120 39.140 J Route 48 ..... I P0(18-8%) 2T(18-8%), P0(18-8%) 74-10% 0.001189 648 39-6 19.13 2.7050 228-7% 0.272 , © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 22 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pt Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) __________________ 39.412 Total(Pt) Route 48 (,© M.E.P.CAD i,11l AutoSPRINK 2023 08.1.38.0 2 5/17/2024 8:28:12AM Page 23 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 2 Date: 5/17/2024 lEquivalent Pipe Lengths of Valves andFittings (C=120 only) IC Value Multiplier I Actual Inside Diameter 4.87 Factor Value Of C 100 130 140 150 I \ = Schedule 40 Steel Pipe Inside Diameter J I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111h° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD 1J AutoSPRINK 2023 v18.1.38.0 2 5/17/2024 8:28:12AM Page 24 Hydraulic Calculations for Project Name: RACEWAY UPS CONVEYORS: (SD0269) Location: 3125 LIONSHEAD AVE, CARLSBAD, CA. 92008, Drawing Name: SD0269 RACEWAY CONVEYORS Design Remote Area Number: 3 Remote Area Location: Conveyor Occupancy Classification: Ordinary Group II Commodity Classification: ORDINARY HAZARD Density 0.20gpm/ft2 Area of Application: 15001t2 (Actual 1519ff2) Coverage per Sprinkler: 130ft2 Type of sprinklers calculated: Upright No. of sprinklers calculated: 22 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Calculation Date: 5/17/2024 Hose Streams: 250.00 at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 1096.81 @ 92.776 (Safety Margin = 27.478) Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A Name of Contractor: Hiller Fire Address: 7130 CONVOY CT, SAN DIEGO, CA. 92111 Phone Number: 858-277-3473 Name of designer: BEN LEDESMA Authority Having Jurisdiction: : CARLSBAD Notes: Automatic peaking results Left: N/A Right: N/A © M.E.P.CAD IN AutoSPRINK 2023 08.1.38.0 3 5/17/2024 8:28:32AM Page 1 Hydraulic Graph Job Name: RACEWAY UPS CONVEYORS N 1.85 Remote Area Number: 3 Date: 5/17/2024 150— Supply L Summa Sheet 135 Node: I - - Static Pressure 120.600 120 --'-L._ 1 1096"81@120.253—......... 105--- 1096.81 with Hose Allowance at Source 10001.00 @ 99.90O—_.•.•••• 90 846.81 @ 92.776 a- 75— 60— S stem demand curve 45H 30 15— 0_lr111111.1IIIIII1I 11111111 IlIIlIII 111111 Iii till II Ill I I I I I I I I I I I I I I I L I I I q150 2300 3450 4600 5750 6900 8050 9200 10350 11500 Flow - gpm Supply:static:120.600 Residual :99.900 Flowing: 10001.00 Available Flow @ 20 PSI:23486.72 (A,©M.E.P.CAD IIII AutoSPRINK 2023 v18.1.38.0 5/17/2024 8:28:34AM Page IIII Summary Of Outfiowing Devices I Job Number: SD0269 Report Description: Ordinary Group 11 (3) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 3070 38.87 26.00 8 23.608 Sprinkler 3071 39.95 26.00 8 24.937 Sprinkler 3105 36.88 26.00 8 21.247 Sprinkler 3106 37.91 26.00 8 22.451 Sprinkler 3162 37.25 26.00 8 21.686 Sprinkler 3163 36.51 26.00 8 20.826 Sprinkler 3164 37.74 26.00 8 22.260 Sprinkler 3192 37.57 26.00 8 22.059 Sprinkler 3193 45.49 26.00 8 32.330 Sprinkler 3194 38.41 26.00 8 23.057 Sprinkler 3222 30.21 26.00 8 14.259 Sprinkler 3223 35.89 26.00 8 20.123 Sprinkler 3224 26.00 26.00 8 10.563 Sprinkler 3259 40.47 26.00 8 25.590 Sprinkler 3260 48.03 26.00 8 36.043 Sprinkler 3261 41.00 26.00 8 26.265 Sprinkler 3293 30.22 26.00 8 14.273 Sprinkler 3294 35.66 26.00 8 19.868 Sprinkler 3295 27.38 26.00 8 11.714 Sprinkler 3305 44.03 26.00 8 30.290 Sprinkler 3306 48.65 26.00 8 36.985 Sprinkler 3307 1 52.69 26.00 8 43.383 c Most Demanding Sprinkler Data © M.E.P.CAD J AutoSPRlNK 2023 v18.1.38.0 5/17/2024 8:28:35AM Page 3 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Supply Analysis Node Name Static (psi) Residual Flow (psi) © (gpm) Available Total Demand (psi) © (gpm) Required Pressure (psi) Water Supply 120.600 99.900 10001.00 120.253 1096.81 92.776 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4-0 Supply 92.776 846.81 3070 14-6 Sprinkler 23.608 38.87 3071 14'-6 Sprinkler 24.937 39.95 3105 14'-6 Sprinkler 21.247 36.88 3106 14-6 Sprinkler 22.451 37.91 3162 14-6 Sprinkler 21.686 37.25 3163 11-6 Sprinkler 20.826 36.51 3164 11'-6 Sprinkler 22.260 37.74 3192 14-6 Sprinkler 22.059 37.57 3193 14-6 Sprinkler 32.330 45.49 3194 14-6 Sprinkler 23.057 38.41 3222 8-6 Sprinkler 14.259 30.21 3223 8-6 Sprinkler 20.123 35.89 3224 8-6 Sprinkler 10.563 26.00 3259 14-6 Sprinkler 25.590 40.47 3260 14-6 Sprinkler 36.043 48.03 3261 14-6 Sprinkler 26.265 41.00 3293 6-6 Sprinkler 14.273 30.22 &©M.E.P.CAD AutoSPRlNK2023v18.1.38. 5/17/2024 8:28:38AM Paqe4 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 3294 6-6 Sprinkler 19.868 35.66 3295 6-6 Sprinkler 11.714 27.38 3305 11-6 Sprinkler 30.290 44.03 3306 11-6 Sprinkler 36.985 48.65 3307 9-71/2 Sprinkler 43.383 52.69 22 4-0 84.366 23 4-0 80.382 24 4-0 81.777 27 -3-0 84.366 30 4-0 81.089 31 4-0 81.777 1601 11-6 28.276 1602 11-6 29.780 1732 11-6 28.330 1735 11-6 29.837 1835 11'-6 28.536 1836 13'-6 25.007 1837 11-6 30.054 1838 13-6 26.356 1950 11-6 28.622 1951 14-0 24.601 2073 11-6 29.346 r. ..© M.E.P.CAD HN AutoSPRINK 2023 v18.1.38. 5/17/2024 8:28:38AM Page 5 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 2076 11-6 42.156 2079 11-6 30.594 2201 11-6 30.058 2205 11-6 42.208 2233 7101/2 16.662 2234 7'-10% 23.324 2269 11-6 30.519 2270 11-6 42.324 2271 11'-6 31.282 2278 7-3 13.268 2280 11-6 31.697 2464 11-6 35.981 2466 11'-6 44.274 2479 39-6 84.366 2535 11-6 42.228 2537 13'-0 51.527 2538 11-6 47.039 2540 13-0 50.793 2544 12-1% 50.931 2546 113h/2 51.282 2559 0-0 84.366 2564 0-0 78.942 (© M.E.P.CAD J AutoSPRINK 2023 v18.1.38. 5/17/2024 8:28:38AM Paqe 6 Job Nane: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 2569 13'-O 71.837 ,©M.E.P.CAD F111 AutoSPRINK2O23v18.1.38. 5/17/2024 8:28:38AM Paqe7 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 3224 8-6 8 26.00 1 (See Notes) 6-1 120 10.563 Route .1 ..... Sprinkler, T(5'- 10) 5-10 0.181014 0.543 2278 7 -3 26.00 1.0830 11'-111/2 2.162 2278 7'-3 27.38 1 (See Notes) 16-9 120 13.268 Flow (q) from Route 2 3E(2-4), PO(5'-10) 12-10 0.684958 -1.844 2280 11-6 53.38 1.0830 29-7 20.273 2280 11-6 195.01 2 (See Notes) 18'6 120 31.697 Flow (q) from Route 11 3E(6'-10), PO(13'-7V2) 34'-1 0.370838 -0.273 2544 12-1 V2 248.39 2.2030 52-7 19.508 2544 12-1 V2 52.69 4 11'-lO _________ 120 ____________ 50.931 ______________ Flow (q) from Route 22 0.020152 -0.377 2540 13-0 301.09 4.3100 11'-lO 0.239 2540 13-0 213.71 4 13-6 120 50.793 Flow (q) from Route 5 0.054360 2537 13-0 514.80 4.3100 13'-6 0.734 2537 13-0 332.01 4 (See Notes) 93'-0 120 51.527 Flow (q) from Route 3 2T(27--1 0%) 56-9 0.136508 2569 13-0 846.81 4.3100 148'-9V2 20.310 2569 13'-0 6 (See Notes) 16'1 120 71.837 E(17'-7), P0(37-81/2) 55-4 0.020569 5.636 2564 0-0 846.81 6.3570 71-5 1.469 2564 01-0 8 (See Notes) 3'0 120 78.942 E(21'E(21'-11/2) 2111/2 0.005783 1.301 23 -3-0 846.81 8.2490 24 11/2 0.140 23 -3-0 8 (See Notes) 88'2 120 80.382 4471/ 0.005325 30 4-0 846.81 8.3900 T(44'-7/2)132-10 0.707 30 -3-0 10 488-8 140 81.089 0.001407 31 4-0 846.81 10.4000 488'-8 0.687 31 4-0 io (See Notes) 1951'5 140 81.777 6E(35'-l), 2T(79'-8V2), BFP(-7. 733),S 369'-10V2 0.001407 I 1 -3-0 846.81 10.4000 i 2321'-3/2 10.999 (,,© M.E.P.CAD ijAutoSPRINK 2023 v18.1.38.0 3 5/17/2024 8:28:40AM Page 8 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pt Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per unit Total when applicable, are added ________________ Friction(Pf) Node 2 (Foot) Actual ID Length (Foot) (psi) directly to (Pt) and shown as (Foot) 250.00 92.776 Hose Allowance At Source Total(Pt) Route 1 1 1096.81 3295 6'-6 8 27.38 1 (See Notes) 3'-7 120 11.714 Route 2 ..... Sprinkler, T(5'-10) 5-10 0.199189 -0.324 2278 7'-3 27.38 1.0830 1.878 13.268 Total(Pt) Route 2 3222 8'-6 8 30.21 1 (See Notes) 3-1 120 14.259 " Route 3"" Sprinkler, T(5'-10) 5'-10 0.238925 0.274 2233 710h/2 30.21 1.0830 8'-11 2.128 2233 7'-10% 30.22 1 (See Notes) 4'6y2 120 16.662 Flow (q) from Route 4 3E(2'-4), PO(5'-10) 12-10 0.861722 -1.575 2201 11'-6 60.43 1.0830 17'-4/2 14.971 2201 11'-6 187.08 2 1-3 120 30.058 Flow (q) from Route 7 0.368414 2269 11'-6 247.52 2.2030 1-3 0.461 2269 11'-6 40.47 2 1121/2 120 30.519 Flow (q) from Route 16 0.487535 2464 11-6 287.98 2.2030 11-2% 5.462 2464 11'-6 44.03 2 (See Notes) 30% 120 35.981 Flow (q) from Route 18 E(6'-10) 0.634323 6-10 2535 11-6 332.01 2.2030 9'-10 6.246 2535 11-6 2 (See Notes) 1'6 120 42.228 P0(10-0) 101-0 0.865133 -0.650 2537 13'-0 332.01 2.0670 11-6 9.949 51.527 Total(Pt) Route 3 3293 6'-6 8 30.22 1 (See Notes) 6'-7% 120 14.273 Route 4 ..... Sprinkler, T(5'- 10) 5'-10 0.239145 -0.593 2233 7-10% 30.22 1.0830 12'-5% 2.981 16.662 Total(Pt) Route 4 3294 6'-6 8 35.66 1 (See Notes) 6'-71/2 120 19.868 Route ..... Sprinkler, T(5'-10 5'-10 0.324737 -0.593 2234 7-10% 35.66 1.0830 12-5% 4.048 f, 0 M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 3 5/17/2024 8:28:40AM Page 9 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) _____________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ________________ Friction(Pf) 2234 7-10% 35.89 i (See Notes) 4'-6% 120 23.324 Flow (q) from Route 6 3E(2'-4), PO(5'-10) 12-10 1.177592 -1.575 2205 11-6 71.55 1.0830 17'-4% 20.459 2205 11-6 45.49 2 1-3 120 42.208 Flow (q) from Route 19 0.092160 2270 11'-6 117.03 2.2030 1-3 0.115 2270 11-6 48.03 2 11-2% 120 42.324 Flow (q) from Route 20 0.174108 2466 11-6 165.06 2.2030 1121/2 1.951 2466 11-6 48.65 2 (See Notes) 3'O% 120 44.274 Flow (q) from Route 21 E(6'-1 0) 6-10 0.280778 2538 11-6 213.71 2.2030 9-10 2.765 2538 11-6 2 (See Notes) 1-6 120 47.039 P0(10'-0) 10-0 0.382944 -0.650 2540 13-0 213.71 2.0670 11'-6 4.404 50.793 Total(Pt) Route 5 3223 8'-6 8 35.89 1 (See Notes) 3-1 120 20.123 Route 6 ..... Sprinkler, T(5'-10) 6-10 0.328578 0.274 2234 7-10% 35.89 1.0830 8'-11 2.927 23.324 Total(Pt) Route 6 3163 11-6 8 36.51 1 (See Notes) 8-9 120 20.826 Route 7 ..... Sprinkler, 2E(2'-O) 4-0 0.396184 -0.868 1836 13-6 36.51 1.0490 12'-9 5.050 1836 13-6 1 (See Notes) 2-0 120 25.007 P0(5-10) 5-10 0.339182 0.868 1835 11-6 36.51 1.0830 7-10 2.660 1835 11'-6 75.75 2 1-0 120 28.536 Flow (q) from Route 8 0.085320 1950 11'-6 112.25 2.2030 0.085 1950 11-6 37.25 2 5-0 120 28.622 Flow (q) from Route 9 0.144979 2073 11-6 149.51 2.2030 5-0 0.725 (, © M.E.P.CAD M11 AutoSPRINK 2023 v18. 1.38.0 3 5/17/2024 8:28:40AM Page 10 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Node I Eiev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fining/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a 139v9 Fitting (Foot) Pf Friction Loss Per unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 2073 11-6 37.57 2 1 120 29.346 Flow (q) from Route 10 0.219499 2201 11-6 187.08 2.2030 3-3 0.712 30.058 Total(Pt) Route 7 3105 14-6 8 36.88 1 (See Notes) 621/2 120 21.247 .".Route 8 ..... Sprinkler, 2E(2'-4), PO(5'-10) 10'-6 0.345526 1.301 1732 11'-6 36.88 1.0830 16-9 5.783 1732 11'-6 38.87 2 5-0 120 28.330 Flow (q) from Route 14 0.041209 1835 11'-6 75.75 2.2030 5-0 0.206 28.536 Total(Pt) Route 8 3162 14-6 8 37.25 1 (See Notes) 261/2 120 21.686 Route ..... Sprinkler, 2E(2-0) 4-0 0.411292 0.217 1951 14'-0 37.25 1.0490 6-6 V2 2.699 1951 14'-0 i (See Notes) 2'-6 120 24.601 PO(5'-10) 51 -'0 0.352116 1.084 1950 11'-6 37.25 1.0830 8-4 2.937 28.622 Total(Pt) Route 9 3192 14-6 8 37.57 i (See Notes) 1 6-2% 120 22.059 ..... Route lO ..... Sprinkler, 2E(2'-4), P0(5-10) 10'-6 0.357725 1.301 2073 11-6 37.57 1.0830 16-9 5.987 29.346 Total(Pt) Route 10 3164 11'-6 8 37.74 1 (See Notes) 7-9% 120 22.260 Route 11 ..... Sprinkler, 2E(2'-O) 4-0 0.421362 -0.868 1838 13'-6 37.74 1.0490 11'-9% 4.964 1838 13'-6 1 (See Notes) 2'0 120 26.356 P0(5-10) 5'-10 0.360738 0.868 1837 11-6 37.74 1.0830 7-10 2.829 1837 11-6 77.86 2 6-0 120 30.054 Flow (q) from Route 12 0.090084 2079 11-6 115.60 2.2030 6'-O 0.541 , © M.E.P.CAD AutoSPRINK 2023 v18.1 .38.0 3 5/17/2024 8:28:40AM Page 11 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pt) 2079 11-6 38.41 2 4'6 120 30.594 Flow (q) from Route 13 0.153165 2271 11-6 154.01 2.2030 4-6 0.688 2271 11-6 41.00 2 1-9 120 31.282 Flow (q) from Route 17 0.237025 2280 11-6 195.01 2.2030 1-9 0.415 31.697 Total(Pt) Route 11 3106 14-6 8 37.91 1 (See Notes) 6-2% 120 22.451 ••••• Route 12•"•• Sprinkler, 2E(2-4), P0(5-10) 10-6 0.363602 1.301 1735 11-6 37.91 1.0830 16-9 6.085 1735 11-6 39.95 2 5-0 120 29.837 Flow (q) from Route 15 0.043357 1837 11'-6 77.86 2.2030 5-0 0.217 30.054 Total(Pt) Route 12 3194 14'-6 8 38.41 1 (See Notes) 6-2% [ 120 23.057 Route 13 .... . Sprinkler, 2E(2-4), P0(5-10) 10-6 0.372665 1.301 2079 11-6 38.41 1.0830 16-9 6.237 30.594 Total(Pt) Route 13 3070 14-6 8 38.87 1 (See Notes) 3-0 120 23.608 Route 14 ..... Sprinkler, PO(5'-l0) 5-10 0.380902 1.301 1601 11'-6 38.87 1.0830 8-10 3.367 1601 11'-6 2 4-6 120 28.276 0.011994 1732 11'-6 38.87 2.2030 4-6 0.054 28.330 Total(Pt) Route 14 3071 14-6 8 39.95 1 (See Notes) 3'0 120 24.937 Route 15 ..... Sprinkler, P0(5-10) 6-10 0.400694 1.301 1602 11'-6 39.95 1.0830 8'-lO 3.542 1602 11'-6 2 4-6 120 29.780 0.012617 1735 11'-6 39.95 2.2030 4-6 0.057 29.837 Total(Pt) Route 15 , © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 3 5/17/2024 8:28:40AM Page 12 I Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 3259 14'-6 8 40.47 1 (See Notes) 3-0 120 25.590 Route 16 ..... Sprinkler, PO(5'-10) 5-10 0.410393 1.301 2269 11'-6 40.47 1.0830 8'-lO 3.628 30.519 Total(Pt) Route 16 3261 14-6 8 41.00 1 (See 1 Notes) 3-0 120 26.265 ..... Route 17 ..... Sprinkler, P0(5-10) 5'-10 0.420396 1.301 2271 11-6 41.00 1.0830 8'-lO 3.716 31.282 Total(Pt) Route 17 3305 11'-6 8 44.03 1 (See 1 Notes) 60h/2 120 30.290 Route 18 ..... Sprinkler, P0(5-10) s'-io 0.479650 I 11'-10Y2 5.692 2464 11-6 44.03 1.0830 35.981 Total(Pt) Route 18 3193 14'-6 8 45.49 1 (See Notes) 6'2% 120 32.330 Route l9..... Sprinkler, 2E(2'-4), P0(5-10) 10'-6 0.509459 1.301 2076 . 11-6 45.49 1.0830 16'-9 8.526 2076 11-6 2 3-3 120 42.156 0.016042 2205 11-6 45.49 2.2030 3-3 0.052 42.208 Total(Pt) Route 19 3260 14'-6 8 48.03 1 (See Notes) J 3-0 120 36.043 Route 20 ..... Sprinkler, P0(5-10) 5'-10 0.563358 1.301 2270 11-6 48.03 1.0830 8'-lO 4.980 42.324 Total(Pt) Route 20 3306 11'-6 8 48.65 1 (See Notes) 1 6-9% 120 36.985 Route 21 ..... Sprinkler, P0(5-10) 5-10 0.576971 2466 11'-6 48.65 1.0830 12'-7% 7.289 44.274 Total(Pt) Route 21 3307 9-7% 8 52.69 1 (See Notes) 4'-9 120 43.383 Route 22 ..... Sprinkler, E(2'-4), PO(5'-10) 8'-2 0.668725 -0.737 2546 11-3% 52.69 1.0830 12'-11 8.636 2546 113h/2 4 7'-2% 120 51.282 0.000802 -0.356 2544 12-1% 52.69 4.3100 7-2% 0.006 ,©M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 3 5/17/2024 8:28:40AM Page 13 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pt) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pt) and shown as (Foot) 50.931 Total(Pt) Route 22 , © M.E.P.CAD 11 AutoSPRINK 2023 v18. 1.38.0 3 5/17/2024 8:28:40AM Page 14 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 3 Date: 5/17/2024 IEauivaIent Pioe Lenoths of Valves and Fittinas (C=120 only) Value Actual Inside Diameter 4.87 Factor Value Of C 100 130 140 150 I \ = Schedule 40 Steel Pipe Inside Diameter / I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 3 5/17/2024 8:28:40AM Page 15 Hydraulic Calculations for Project Name: RACEWAY UPS CONVEYORS: (5D0269) Location: 3125 LIONSHEAD AVE, CARLSBAD, CA. 92008, Drawing Name: SD0269 RACEWAY CONVEYORS Calculation Date: 5/17/2024 Design Remote Area Number: 4 Occupancy Classification: Ordinary Group II Commodity Classification: ORDINARY HAZARD Density 0.20gpm/ft2 Area of Application: 1500ft2 (Actual 712ft2) Coverage per Sprinkler: 130ft2 Type of sprinklers calculated: Upright No. of sprinklers calculated: 11 No. of nozzles calculated: 0 In-rack Demand: N/Agpm at Node: N/A Hose Streams: 250.00 at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 618.09 @ 111.707 (Safety Margin = 8.773) Type of System: WET Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A Name of Contractor: Hiller Fire Address: 7130 CONVOY CT, SAN DIEGO, CA. 92111 Phone Number: 858-277-3473 Name o. designer: BEN LEDESMA Authority Having Jurisdiction: : CARLSBAD Notes: Automatic peaking results Left: N/A Right: N/A M.E:P.CAD AutoSPRINK 2023 08.1.38.0 4 5/17/2024 8:29:20AM Page 1 4600 6900 9200 5750 8050 10350 Flow - gpm Supply:static:120.600 Residual:99.900 Flowing: 10001.00 Available Flow @ 20 PSI:23486.72 (.,© M.E.P.CAD RI I AutoSPRINK 2023 v18.1.38.0 5/17/2024 8:29:21AM Paqe 2 11500 lb 75 0 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 150- 135 120 105 60 45 30 15 I Supply Summary Sheet L_ Node:1 Static Pressure 120.600 618.09 with Hose Allowance at 368.09111.707 S 10001.00 - c ystem demand curve - --- iiiiiii Hydraulic Graph N 1.85 Date: 5/17/2024 IIISummary Of Outfiowing Devices Job Number: SD0269 Report Description: Ordinary Group II (4 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 2749 49.08 26.00 8 37.645 Sprinkler 2764 43.89 26.00 8 30.093 Sprinkler 2796 39.48 26.00 8 24.358 Sprinkler 2819 35.83 26.00 8 20.058 Sprinkler 2834 32.88 26.00 8 16.892 Sprinkler 2849 30.59 26.00 8 14.625 Sprinkler 2923 28.92 26.00 8 13.067 Sprinkler 2962 27.79 26.00 8 12.066 Sprinkler 3000 27.12 26.00 8 11.490 Sprinkler 3026 26.51 26.00 8 10.978 c' Sprinkler 3036 1 26.00 1 26.00 1 8 1 10.563 1 a> Most Demanding Sprinkler Data & © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 5/17/2024 8:29:23AM Page 3 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 120.600 99.900 10001.00 120.480 618.09 111.707 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 Supply 111.707 368.09 2749 2-0 Sprinkler 37.645 49.08 2764 2-0 Sprinkler 30.093 43.89 2796 2-0 Sprinkler 24.358 39.48 2819 2-0 Sprinkler 20.058 35.83 2834 2-0 Sprinkler 16.892 32.88 2849 2-0 Sprinkler 14.625 30.59 2923 2-0 Sprinkler 13.067 28.92 2962 2-0 Sprinkler 12.066 27.79 3000 2-0 Sprinkler 11.490 27.12 3026 2-0 Sprinkler 10.978 26.51 3036 1-0 Sprinkler 10.563 26.00 22 -3-0 102.130 23 -3'-0 101.575 24 4-0 101.424 27 -3'-0 102.130 30 4-0 101.575 31 4-0 101.575 (&©M.E.P.CAD Ill AutoSPRlNK2023v18.1.38. 5/17/2024 8:29:26AM Paqe4 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 121 39-6 81.750 136 39'-6 80.927 214 39'-6 80.904 216 39'-6 81.750 345 19-0 84.128 352 39'-6 80.861 471 39-6 81.013 473 39-6 81.752 482 2-0 41.364 531 39'-6 81.177 533 39-6 81.756 546 2-0 33.116 586 39'-6 81.309 588 39'-6 81.763 664 39-6 81.418 666 39-6 81.771 675 2-0 26.844 737 39-6 81.506 739 39'-6 81.782 756 2-0 22.135 789 39'-6 81.579 791 39-6 81.796 ,,© M.E.P.CAD AutoSPRlNK 2023 v18.1.38. 5/17/2024 8:29:26AM Paqe 5 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 813 2-0 18.664 843 39'-6 81.640 845 39-6 81.811 942 39-6 81.690 944 39-6 81.828 956 2-0 16.176 1001 39'-6 81.733 1003 39-6 81.848 1116 2-0 14.465 1150 39-6 81.769 1152 39'-6 81.870 1239 39-6 81.798 1241 39-6 81.893 1276 2-0 13.364 1326 39'-6 81.822 1328 39-6 81.917 1384 2-0 12.731 1419 39-6 81.841 1421 39-6 81.943 1480 2-0 12.605 1481 1-0 11.347 1536 39'-6 81.857 ,© M.E.P.CAD J AutoSPRINK 2023 08.1.38. 5/17/2024 8:29:26AM Page 6 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1538 39-6 81.972 1643 39'-6 81.868 1645 39-6 82.003 1983 39-6 81.875 1985 39-6 82.038 2314 39-6 81.878 2316 39'-6 82.074 2479 39-6 102.130 2503 39-6 81.883 2505 39'-6 82.115 2559 0-0 102.130 2564 0-0 101.575 2569 13-0 101.575 ,©M.E.P.CAD JAutoSPRlNK 2023 08.1.38. 5/17/2024 8:29:26AM Page 7 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as ___ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pt) 3036 1-0 8 26.00 1 (See Notes) 2-0 120 10.563 Route ..... Sprinkler, E(2'-4) 2-4 0.181014 1481 1-0 26.00 1.0830 4-4 0.785 1481 11-0 i (See Notes) 11-0 120 11.347 E(2'-4), C(5'-O) 7-0 0.211435 -0.434 1480 2-0 26.00 1.0490 8-0 1.691 1480 2-0 26.51 2 6-0 120 12. 605 Flow (q) from Route 2 0.020920 1384 2-0 52.51 2.2030 6-0 0.126 1384 2'-0 27.12 2 14-0 120 12. 731 Flow (q) from Route 3 0.045196 1276 2-0 79.62 2.2030 14'-0 0.633 1276 2-0 27.79 2 14'-O 120 13.364 Flow (q) from Route 4 0.078636 1116 2'-0 107.41 2.2030 14'-0 1.101 1116 2-0 28.92 2 14'-O 120 14.465 Flow (q) from Route 5 0.122229 14-0 956 2-0 136.33 2.2030 1.711 956 2-0 30.59 2 14'-O 120 16.176 Flow (q) from Route 6 0.177762 813 2-0 166.93 2.2030 14-0 2.489 813 2-0 32.88 2 14-0 120 18.664 Flow (q) from Route 7 0.247912 756 2-0 199.81 2.2030 14'-0 3.471 756 2'-0 35.83 2 14'-0 120 22. 135 Flow (q) from Route 8 0.336368 14-0 675 2-0 235.63 2.2030 4.709 675 2-0 39.48 2 14-0 120 26.844 Flow (q) from Route 9 0.448005 546 2-0 275.12 2.2030 14'-0 6.272 546 2-0 43.89 2 14'-O 120 33. 116 Flow (q) from Route 10 0.589109 482 2'-0 319.00 2.2030 14-0 8.248 © M.E.P.CAD AutoSPRINK 2023 v1 8.1.38.0 4 5/17/2024 8:29:28AM Page 8 r Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 - Elev 2 (Foot) Total Flow Actual ID Total (Foot) ________________ Friction(Pf) 482 2'-0 49.08 2 (See Notes) 31'2% 120 41.364 Flow (q) from Route 11 2P0(13-7%), E(6'-10) 34'-1 0.767688 -7.370 345 19-0 368.09 2.2030 65-3% 50.134 345 191 0 4 (See Notes) 119101,4 120 84.128 2P0(27'-10Y2),BV(16-8%) 72'-5% 0.029225 -8.888 352 39'-6 368.09 4.3100 192-4 5.621 352 39'-6 4 (See Notes) 2'5 120 80.861 PO(26'-4) 26-4 0.001448 0.001 214 39'-6 70.33 4.2600 28'-9 0.042 214 39'-6 21/2 (See Notes) 161'9 120 80.904 2T(18'-8%), P0(18-8%) 56-2 0.003885 216 39-6 36.28 2.7050 217'-11 0.847 216 39-6 34.05 6 9-8 120 81.750 Flow (q) from Route 13 0.000206 473 39'-6 70.33 6.3570 9-8 0.002 473 39'-6 32.24 6 9-8 120 81.752 Flow (q) from Route 12 0.000414 533 39'-6 102.57 6.3570 9-8 0.004 533 39'-6 28.27 6 9-8 120 81.756 Flow (q) from Route 16 0.000650 588 39'-6 130.85 6.3570 9'-8 0.006 588 39'-6 24.75 6 9-8 120 81.763 Flow (q) from Route 17 0.000895 666 39'-6 155.60 6.3570 9-8 0.009 666 39-6 21.65 6 9-8 120 81.771 Flow (q) from Route 28 0.001139 739 39'-6 177.25 6.3570 9-8 0.011 739 39'-6 18.93 6 9-8 120 81.782 Flow (q) from Route 29 0.001375 791 39'-6 196.18 6.3570 9-8 0.013 791 39'-6 16.59 6 9-8 120 81.796 Flow (q) from Route 22 0.001597 845 39-6 212.77 6.3570 9'-8 0.015 (, © M.E.P.CAD 1011 AutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 9 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID __________ Total (Foot) ________________ Friction(Pf) 845 39'-6 14.61 6 9'-8 120 81. 811 Flow (q) from Route 23 0.001806 944 39-6 227.38 6.3570 9-8 0.017 944 39-6 13.01 6 9-8 120 81. 828 Flow (q) from Route 24 0.002002 1003 39-6 240.39 6.3570 9-8 0.019 1003 39'-6 11.80 6 10-0 120 81. 848 Flow (q) from Route 20 0.002188 1152 39-6 252.20 6.3570 10-0 0.022 1152 39-6 10.97 6 9-8 120 81.870 Flow (q) from Route 21 0.002367 1241 39-6 263.16 6.3570 9-8 0.023 1241 39-6 10.58 6 9-6 120 81. 893 Flow (q) from Route 14 0.002546 1328 39-6 273.74 6.3570 9-6 0.024 1328 39'-6 10.61 6 9-6 120 81. 917 Flow (q) from Route 15 0.002732 1421 39-6 284.36 6.3570 9-6 0.026 1421 39-6 11.03 6 10-0 120 81. 943 Flow (q) from Route 25 0.002931 1538 39-6 295.38 6.3570 10-0 0.029 1538 39-6 11.82 6 10-0 120 972 Flow (q) from Route 26 0.003152 1645 39-6 307.20 6.3570 101-0 0.032 1645 39-6 12.91 6 10'-O 120 82.003 Flow (q) from Route 27 0.003401 10-0 1985 39-6 320.11 6.3570 0.034 1985 39-6 14.23 6 10-0 120 038 Flow (q) from Route 35 0.003686 2316 39-6 334.34 6.3570 10-0 0.037 2316 39-6 15.73 6 10-0 120 82. 074 Flow (q) from Route 18 0.004013 2505 39'-6 350.07 6.3570 101-0 0.040 © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 10 Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5117/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) Loss Per Unit (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot ) 2505 39'-6 18.01 6 (See 103'6 120 82.115 Flow (q) from Route 19 9061/ 17.124 Notes) 2571 01-0 368.09 6.3570 0.004404 3E(17'-7), PO(37'-8Y2) 194'-O% 0.854 2571 01-0 8 (See 3'-0 120 100.093 2111/2 1.301 Notes) 24 -3-0 368.09 8.2490 0.001238 E(21'-11/2) 2411/2 0.030 24 -3'-0 8 (See 88'2 120 101.424 44'71/ Notes) 31 4-0 368.09 8.3900 0.001140 1(44-7%) 132-10 0.151 31 -3-0 io (See 1951'5 140 101.575 369101,4 Notes) 1 -3-0 368.09 10.4000 0.000301 6E(35'-l), 2T(79'-81/2), BFP(-9. 2321-3% 10.132 433),_S 250.00 111.707 Hose Allowance At Source Total(Pt) Route 1 1 618.09 3026 2-0 8 26.51 1 (See 0'6 120 10.978 Route ..... Sprinkler, 8-2 Notes) 1480 2'-0 26.51 1.0830 0.187588 E(2'-4), C('C(6-10)lO) 8 1.628 12.605 Total(Pt) Route 2 3000 2'-0 8 27.12 1 (See 0'-6 T 120 11.490 ..... Route 3..... Sprinkler, 51 10 Notes) 1384 2'-0 27.12 1.0830 0.195674 P0(5-10) 6'-4 1.241 12.731 Total(Pt) Route 3 2962 2-0 8 27.79 1 (See 0-6 1 120 12.066 Route 4 ..... Sprinkler, 6-10 Notes) 1276 2-0 ' 27.79 1.0830 0.204721 P0(5-10) 6-4 1.298 13.364 Total(Pt) Route 4 2923 2'-0 8 28.92 1 (See 0'6 J 120 13.067 Route ..... Sprinkler, 5-10 Notes) 1116 2'-0 28.92 1.0830 0.220393 PO(5'-110) 6'-4 1.397 14.465 Total(Pt) Route 5 (,,© M.E.P.CAD AutoSPRlNK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 11 I Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Poand shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 2849 2-0 8 30.59 1 (See Notes) 0-6 120 14.625 Route 6 ..... P0(5'-1 0) 0.244592 6-10 Sprinkler, 956 2-0 30.59 1.0830 6-4 1.551 16.176 Total(Pt) Route 6 2834 2-0 8 32.88 1 (See Notes) 0-6 120 16.892 Route 7•"•• Sprinkler, P0(5'-10) 5'-10 0.279476 813 2-0 32.88 1.0830 6'-4 1.772 18.664 Total(Pt) Route 7 2819 2-0 8 35.83 1 (See Notes) 0-6 120 20.058 Route ..... Sprinkler, PO(5'-10) 5'-10 0.327602 756 2-0 35.83 1.0830 6'-4 2.077 22.135 Total(Pt) Route 8 2796 2'-0 8 39.48 1 (See Notes) I 0-6 120 24.358 ..... Route 9 ..... Sprinkler, P0(5-10) 6-10 0.392084 675 2-0 39.48 1.0830 6-4 2.486 26.844 Total(Pt) Route 9 2764 2-0 8 43.89 1 (See Notes) 1 0-6 120 30.093 Route 10 ..... Sprinkler, P0(5-10) 5-10 0.476778 546 2-0 43.89 1.0830 6-4 3.023 33.116 Total(Pt) Route 10 2749 2-0 8 49.08 1 (See Notes) I I 0-6 120 37.645 Route 11 Sprinkler, P0(5-10) 5-10 0.586493 482 2'-0 49.08 1.0830 6-4 3.719 41.364 Total(Pt) Route 11 352 39-6 70.33 4 7-3 120 80.861 Route 12 ..... Flow (q) from Route 1 0.020897 0.001 471 39-6 297.76 4.2600 7-3 0.151 471 39'-6 21/2 (See Notes) 161'9 120 81.013 2T(18'-8V2), P0(18-8%) 0.003123 74'-10Y2 P0(1 473 39'-6 32.24 2.7050 236'-7Y2 0.739 81.752 Total(Pt) Route 12 ,© M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 12 ( Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 214 39'-6 4 (See Notes) 8'-0 120 80.904 Route 13 ..... P0(26'-4) P0(26-4) 52-8 0.000378 136 39-6 34.05 4.2600 60-8 0.023 136 39'-6 21,4 (See Notes) 163'5 120 80.927 2T(18'-8%), 2E(9'-4%), P0(18'- 8%) 74'-10'/2 0.003454 121 39'-6 34.05 2.7050 ____ 238'-3% 0.823 121 39'-6 6 9-8 120 81.750 0.000054 216 39-6 34.05 6.3570 9-8 0.001 81.750 Total(Pt) Route 13 1239 39'-6 104.93 2% (See Notes) 161-9 1 120 81.798 Route 14•"•. P0(18-8%), Flow (q) from Route 33 2T(18'-81/2), P0(18-8%) 74'-1 O% 0.000398 ______________ 1241 39-6 10.58 2.7050 236'-7% 0.094 81.893 Total(Pt) Route 14 1239 39-6 104.93 4 9-6 120 81.798 "" Route 15 ..... Flow (q) from Route 33 0.002493 1326 39'-6 94.35 4.2600 9-6 0.024 1326 39'-6 2% (See Notes) 1611 9 120 81.822 P0(18-8%) 2T(18'-8%), P0(18-8%) O% 1328 39'-6 10.61 2.7050 0.000400 :2~36'1-:7% 0.095 81.917 Total(Pt) Route 15 531 39-6 265.52 21/2 (See Notes) 161'9 T 120 81.177 Route 16 ..... P0(18-8%), Flow (q) from Route 30 2T(18'-8%), P0(18-8%) 74-10 % 0.002449 _______________ 533 39-6 28.27 2.7050 236-7% 0.580 81.756 Total(Pt) Route 16 531 39-6 265.52 4 9-8 120 81.177 ••••• Route 17 ..... Flow (q) from Route 30 0.013726 586 39-6 237.24 4.2600 9'-8 0.133 586 39-6 21/2 (See Notes) 161'9 120 81.309 P0(18-8%) 2T(18'-8%), P0(18-8%) 74'-1O % 0.001915 588 39'-6 24.75 2.7050 236'-7% 0.453 81.763 Total(Pt) Route 17 (,© M.E.P.CAD ijAutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 13 t Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 2314 39'-6 33.74 21/2 (See Notes) 161'-g 120 81.878 Route 18 ..... P0(18-81/2), Flow (q) from Route 36 2T(18'-81/.), P0(18-81/2) 741O1/ 0.000828 _______________ 2316 39-6 15.73 2.7050 236-71/2 0.196 82.074 Total(Pt) Route 18 2314 39-6 33•74 4 (See Notes) 10-0 120 81.878 Route 19 ..... Flow (q) from Route 36 PO(26'-4) 26-4 0.000116 2503 39'-6 18.01 4.2600 36-4 0.004 2503 39-6 21/2 (See Notes) 161'9 120 81.883 2T(18-81/2), P0(18-81/2) 56'-2 0.001064 2505 39'-6 18.01 2.7050 217'-11 0.232 82.115 Total(Pt) Route 19 1001 39-6 127.69 2h z (See Notes) I 161-9 120 81.733 Route 20 ..... P0(1 8'-8'/2), Flow (q) from Route 32 2T(18'-8%), P0(18-81/2) 74-101/2 0.000486 ______________ 1003 39-6 11.80 2.7050 I 236'-7% 0.115 81.848 Total(Pt) Route 20 1001 39'-6 127.69 4 10-0 120 81.733 Route 21 ..... Flow (q) from Route 32 0.003647 1150 39-6 115.89 4.2600 10-0 0.036 1150 39-6 2% (See Notes) 161'-9 120 81.769 2T(18'-81/2), P0(18-8%) 0.000425 74'-10'/2 P0(1 1152 39'-6 10.97 2.7050 236-71/2 0.101 81.870 Total(Pt) Route 21 737 39-6 4 9-8 120 81.506 Route 22 ..... 0.007564 789 39-6 171.91 4.2600 9-8 0.073 789 39-6 2% (See Notes) 161'-9 120 81.579 P0(18-8%) 2T(18'-8%), P0(18-8%) 74'-lO% 0.000913 791 39-6 16.59 2.7050 236-7% 0.216 81.796 Total(Pt) Route 22 843 39-6 155.32 21/2 (See Notes) 1619 1 120 81.640 Route 23 ..... P0(18-8%), Flow (q) from Route 31 2T(18'-8%), P0(18-8%) 7410% 0.000722 845 39-6 14.61 2.7050 236'-7% ______________ 0.171 81.811 Total(Pt) Route 23 (. © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 14 , , Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information El v1v Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Fo K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) Loss Per Unit (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pfl and shown as (Foot) 9-8 120 81.640 Route 24 ..... 843 39'-6 155.32 4 Flow (q) from Route 31 0.005222 942 39'-6 140.71 4.2600 9'-8 0.050 942 39'-6 2% (See 161'9 120 81.690 P0(18-8%) 7410h/2 Notes) 944 39'-6 13.01 2.7050 0.000583 21(18'-8%), P0(18-8%) 2367h/2 0.138 81.828 Total(Pt) Route 24 1419 39'-6 83.73 2% (See 161'-9 1 120 81.841 Route 25 ..... Notes) P0(18-8%), Flow (q) from Route 34 74'-1 O% ______________ 1421 39'-6 11.03 2.7050 0.000429 21(18-8%), P0(18-8%) 236'-7% 0.102 81.943 Total(Pt) Route 25 1419 39'-6 83.73 4 101-0 120 81.841 Route 26 ..... Flow (q) from Route 34 0.001539 1536 39'-6 72.71 4.2600 10-0 0.015 1536 39-6 21/2 (See 1611 9 120 81.857 P0(18-8%) 74'-10 l 0% Notes) 1538 39'-6 11.82 2.7050 0000488 2T(18'-8%), P0(18-8%) 236-7% 0.115 81.972 Total(Pt) Route 26 101-0 120 81.857 Route 27 ..... 1536 39'-6 11.82 4 Flow (q) from Route 26 0.001109 1643 39'-6 60.89 4.2600 10'-O 0.011 1643 39-6 21/2 (See 1611 9 120 81.868 P0(18-8%) -O% Notes) 1645 39-6 12.91 2T(18-8%), P0(18-8%) 2.7050 0.000574 :2~36'1-7% 0.136 82.003 Total(Pt) Route 27 586 39-6 24.75 4 9-8 120 81.309 Route 28 ..... Flow (q) from Route 17 0.011194 664 39-6 212.49 4.2600 9-8 0.108 664 39-6 2% (See 161'9 120 81.418 Notes) P0(18-8%) 74-101/2 666 39'-6 21.65 2.7050 0.001495 21(18'-81/2), PO(18'-8%) 236-7% 0.354 81.771 Total(Pt) Route 28 , © M.E.P.CAD J AutoSPRINK 2023 v18.1 .38.0 4 5/17/2024 8:29:28AM Page 15 I Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 664 39-6 21.65 4 9-8 120 81.418 Route 29 ..... Flow (q) from Route 28 0.009176 737 39-6 190.84 4.2600 9-8 0.089 737 39'-6 2% (See Notes) 161'9 120 81.506 P0(18-8%) 2T(18'-8%), P0(18-8%) 74101/2 0.001166 739 39'-6 18.93 2.7050 236'-71/2 0.276 81.782 Total(Pt) Route 29 471 39-6 32.24 4 9-8 120 81.013 ••••• Route 3O••••• Flow (q) from Route 12 0.016904 531 39'-6 265.52 4.2600 9 -8 0.163 81.177 Total(Pt) Route 30 789 39-6 16.59 4 9-8 120 81.579 Route 3I..... Flow (q) from Route 22 0.006269 843 39-6 155.32 4.2600 9-8 0.061 81.640 Total(Pt) Route 31 942 39-6 13.01 4 1 1 9-8 120 81.690 Route 32 ..... Flow (q) from Route 24 0.004364 1001 39-6 127.69 4.2600 9-8 0.042 81.733 Total(Pt) Route 32 1150 39'-6 10.97 4 1 9-8 120 81.769 Route 33 ..... Flow (q) from Route 21 1 9-8 0.003034 1239 39-6 104.93 4.2600 0.029 81.798 Total(Pt) Route 33 1326 39-6 10.61 4 J 9-6 120 81.822 ••"• Route 34 ..... Flow (q) from Route 15 1 9-6 0.001999 1419 39-6 83.73 4.2600 0.019 81.841 Total(Pt) Route 34 1643 39-6 12.91 4 101-0 120 81.868 ..... Route 35 ..... Flow (q) from Route 27 0.000713 1983 39'-6 47.98 4.2600 10-0 0.007 1983 39-6 2% (See Notes) 161'9 120 81.875 2T(18-8%), P0(18-8%) 0.000688 74'-10Y2 P0(1 1985 39-6 14.23 2.7050 236'-7% 0.163 ©M.E.P.CAD I§1AutoSPRlNK 2023 08.1.38.0 4 5/17/2024 8:29:28AM Page 16 , Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 Date: 5/17/2024 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) ___________ Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit Total when applicable, are added ________________ Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) 82.038 J Total(Pt) Route 35 101-0 120 81.875 Route 36 ..... 1983 39'-6 14.23 4 Flow (q) from Route 35 0.000372 2314 39-6 33.74 4.2600 10'-O 0.004 81.878 Total(Pt) Route 36 © M.E.P.CAD AutoSPRINK 2023 v1 8.1.38.0 4 5/17/2024 8:29:28AM Page 17 Date: 5/17/2024 Value Job Name: RACEWAY UPS CONVEYORS Remote Area Number: 4 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter 4.87 Value Of C 100 130 140 150 I \ =Factor Schedule 40 Steel Pipe Inside Diameter ) I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 900 Elbow EE 45° Elbow Eel 11 114* Elbow Ee2 22Y2° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirE Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD AutoSPRINK 2023 v18.1.38.0 4 5/17/2024 8:29:28AM Page 18