Loading...
HomeMy WebLinkAbout3207 GREY HAWK CT; ; AS060251; Permit11/7/24, 4:11 PM AS060251 Permit Data City of Carlsbad Sprinkler Permit 3207 GREY HAWK Job Address: CT Permit Type: SPRINK Parcel No: 2210150100 Lot #: 0 Reference No.: Permit No: AS060251 Status: ISSUED Applied 10/18/2006 Approved: 10/18/2006 Issued: 10/18/2006 PC #: Inspector: Project Title: ALTIUM, CONCOURSE ONE #100 TI FIRE SPRINKLER INSPECTION Applicant: LINDLEY FIRE PROTECTION 2220 E VIA BURTON ANAHEIM CA 714-535-5761 Owner: CONCOURSE ONE LLC 9820 WILLOW CREEK RD #400 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 60 0 60 -124 about:blank 1/1 LI F EC: ~N D IL~ 11 N I L LINDLEY FIRE PROTECTION Co. 2220 E. VIA BURTON ANAHEIM, CA LINDLEY FIRE PROTECTION FIRE SPRINKLER HEAD SPECIFICATION SHEETS 2220 E. Via Burton Anaheim, California 92806 (714)535-5761 FAX (714)535-0576 California • Nevada • Oregon 0 Oklahoma • Arizona TY3231 - Pendant 5.61K, 1/2-NPT TY4131 - Upright 8.0K, 3/4NPT TY4231 - Pendant 8.01C, 314NPT Technical Data I Fire& Building roducts Customer SsM: Technical Services: Tel: (800) 381-9312 / Fax: (800)791-5500 Tel: (414)570-5000/(800)558.5236 Fax: (414) 570-5010 / (800) 877-1295 Series "FRB - 2.442 5.8, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, 99 Standard Coverage General Description The Series TY-FRB, 2.8,4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is Intended for use In areas with a finished calling. It uses either a two-piece Style 10 (1t2 inch NPT) or Style 40 (3f4 inch NPT) Recessed Es- cutcheon with 1/2 Inch (12,7 mm) of recessed adjustment or up to 3/4 Inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1,2 Inch NPT) or 19 30(3/4 Inch NPT) Recessed Escutcheon with 1/4 Inch (8,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- PORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING' that provides cautions with respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and In- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate In a fire situation or cause It to operate prematurely. mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies the testing is not representative Of all possible cor- rosive atmospheres. secluently It Is recommended that the and user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An Intermediate level versions of the Series TY-FRB Pendant Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed In Technical Data Sheet TFP780 Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval Information Including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Dlecharg Coefficient K = 2.8 PM/psi1/2 (40,3 LPMibar' K = 4.2 GPMIsi1I2 (60,5 LPMsbar1 K = 5.6 GPMsl112 (80,6 LPMibar112 K = 8.0 GPMel1/2 (115,2 LPMlbar'/) Temperature Ratings Refer to Table A and B WARNR4GS The Series 7Y-FRB Sprinklers de- scribed herein must be installed and maintained In compliance with this documen4 as well as with the applica- ble standards of the National Fire Pro- tection AuodetIon in adcttlon to the standards oliny otharauthoritlas hav- ing Jurisdiction. Failure to do so may kopek the pesfoimance Of do. The owner is responsible for maintain- ing their fire protection system and do- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYI13I - UprIght 28K, 1/2-NPT 1Y1231 - Psndsnt 2.8K, IP4NPT TY2131 - Upright 42K, 1NPT TY2231 - Psndsnt 4.21C, 1/2'NPT TY3131 - UprIght 5.81K, 1P2NPT ftne I of 8 JULY 2004 V10474 ESCUTCHEON 7/16' (11.1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON WRENCH 2? SSP DEFLECTOR * l — 2-7/8' (73.0 mm) DIA. Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature Is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Pa" 2 of S TFPI7I SSU* DEFLECTOR 01 7/16' (11,1 mm) NOMINAL MAKE-IN 4 2-3/18' (55,6mm) 1/2NPT** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION From 3- Sss5ig 4-Bulb 6- Deromw Temperature rating Is Indicated on deflector or adjacent to 8uttcn Au.mbly 5- Compr,sslon 7- Ikaft ordioe we on frame. Screw PIpe thread connections per ISO 7/1 can be provided on Special mquea FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (7Y1131) AND PENDENT (TV1231) SPRINKLERS 2.8 K-FACTOR, 1,2 INCH NPT ESCUTCHEON 7/16'(11,1 mm) STYLE 100r20 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON 2-3/W (55, mm) 1-112' (38lj mm) = SSP DEFLECTOR * 2-7/8' (73.0 mm) DIA. PENDENT 1-Frame 3-SseiWig 2- BUtIDn Au.mbly FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY2131) AND PENDENT (7Y2231) SPRINKLERS 4.2 K-FACTOR, 1,2 I4CH NPT SSu* DEFLECTOR ____ IJVTNI 1 7/16' (11,1 mm) 1 NOMINAL MAKE-IN -Mr 2 __ I (55.6 mm) FLATS ii? NPT** 6* 5 RECESSED PENDENT UPRIGHT CROSS SECTION Bulb • - Os6s *lbmP.f_&Uri rathi9 Is indicated on deflector or 4aceot I Ccmpruuion orifice seat on Screw Pfpe thread connections per ISO 7/1 can be provided on — request. Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Recessed Escutcheon: White Coated, Deflector ....... Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) ........Bronze Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel wiTeflont TFPI7I Page 3.1S ESCUTCHEON PLATE SEATING SURFACE 2J1 \ (55.6 MM) f 1-1,2' (38,1 mm) SSP DEFLECTOR * 7/16' (11,1 mm) ** NOMINAL MAKE-IN NPT I STYLE 10or20 RECESSED ESCUTCHEON WRENCH ial FLATS 2-7w ,0 mm) DI& 7/16' I (11,1 MM)I NOMINAL I MAKE-IN 2416' I (55,8 mm) -r 1PZNPT** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION Frwni 3- Sealing 4- Bulb 8- DIscIor Tmp.mturs rating Is Indicated on deflector or a4acent to Button Assembly 5- camp otifice east an frame. Screw "Pipe thread connections per ISO 7/1 can be provided on special mq FIGURE S QUICK RESPONSE SERIES 7Y-FRB UPRIGHT (TY3131) AND PENDENT (TV3231) SPRINKLERS 5.8 K-FACTOR, IN INCH NPT ESCUTCHEON 1/2'(12,7mm) STYLE 30 0r40 PLATE SEATING •** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON DEFLECTOR Jir ___ NPT T(l27lm) ___ MAKE-IN (58 7MM) /tf_11 111 NOMINAL Ts I i 'U (*7mm)J WRENCH I (52mm) SSPDEFLECTOf 2-716'(73,O mm) DLA. 3/4NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION Fmm. 3- 8i&ig 4-Bulb 8- Deflector * Temperature rating Is Indicated on deflector or atacent to Button Msenthly 5- Comprssslon ow an frame. SCraW "Pip thread connections per ISO 7/1 can be provided on epedal request FIGURE 4 QUICK RESPONSE SERIES TY-FRS UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 9.0 K.FACTOF V4 INCH NPT Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed In ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing Is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of We Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, Is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be Installed In accordance with the follow- ing Instructions: NOTES Do not Install any bulb Pipe sprinkler If the bulb Is cracked or there Is loss of liquid from the bulb. With the sprinkler TFPI7I Pa" 4 of S SPRINKLER FPSSH (S.. Nos 7) TYPE TEMP. BULB LIOUD NATURAL BRASS I I ct'iio PLATED JPOLYESTEI I - 2.8 1/2• NPT PENDENT (TY1231) arldl UPRIGHT (TYI13I) 136FiE7C Orange 1,2,3,5 155°F/8rC Rid 175'F/7rC Yellow 200F193°C Green 2SF/14?C Blue 1WFi57-C Orange 1,2,5 RECIAM PENDENT (muir • 15rFwC Red 175OF/7C Yellow 200F3C Green RECESSED PENDENT (1y11)" Rgsts 135-FTC Orange 1560F8°C Rid 175°F/WC Yellow °F/3°C Green 4.2 NPT PENDENT __ (TVfl__) and UPRIGHT (TY2131) 1350F/5TC Orings 1.2 155°F/68°C Red 175°F/790C Yellow °F,3°C Green 2WF1141*Cl Blue RECESSED PENDENT (TY31) Flgw. 7 135F/57°C Orange 155°Fm80C Red 175°F/79°C Yellow 200F/93°C Green RECESSED PENIDENT (I W223 P1gw. 8 135F/5M Orange 156FIErC Red 175F/791C Yellow 200F4e3°C Green NOS: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use Ni Canada (C-UL) as Quick Response Approved by Factory Mutual Research Corporation (FM) as Quick Response Spifri- kiers. S. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the eprin- dare are UL and C-UL Listed as Corrosion Resistant Sprinklers * Installed with Sfl,1e 10 (Ii? NPT) or Style 40 (3/4 NPT) 3AV Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (hr NPT) or Style 30 (3/4 NPT) 1,2 Total Adjustment Recessed Escutcheon, as applicable. - Rims and Deflector only Listings and approvis apply to color (Spenisi Order). NIA: Not Available TABLE A LABORA TORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS inch NPT sprinkler joint should be ob- tek,ed with a torque of 10 to 20 fte. (13,4 to 26,8 Nm). A maximum of 30 ft. ft. (40,7 Nm) of torque Is to be used to Install sprinklers with 34 NPT con-n.ctlons. Higher levels of torque may distort the sprinkler Inlet and cetera leakage or Impairment of the sprinkler. Do not attempt to make-up for Insuffi- cient adjustment in the escutcheon plate by under- or owr-uØdanlrç the sprinkler. Readjust the position of the sprinkler fitting to suit The Series TY-FRB Psndsnt and Up- right Sprinklers must be Installed In accordance with the following Instruc- tions. Step 1. Pendant sprinklers are to be Installed In the pendant position, and upright sprinklers are to be Installed In the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler Into the sprinkler fitting. Step 3. Tighten the sprinkler Into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2. 3, and the W-Type 6 Sprinkler Wrench Is to be applied to the sprinkler wrench fiats. The Series TV-FRO Recessed Pen- dnt Sprinklers must be installed In accordance with the following Instruc- tions. Step A. After Installing the Style 10. 20, 30.or40 Mounting Plate, asappl- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler Into the sprinkler fitting. Step B. lighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1. 2, 3, and 4, the W-1pe 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plled, slide on the Style lo,20, 30,01 40 Closure over the Series TY.FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. held horizontally, a small air bubble should be present. The diameter of the air bubble Is appraxlmatety 1/16 Inch (1,6 mm) for the 135°F/52-C to 3/32 inch (2,4 mm) for the 286°F/1410C temperature ratings. A leak tight 1,2 inch NPTsprinkl.rjoint should be obtained with a torque of 7 to 14 Sib.. (9,5 to 19,0 Nm). A maxi- mum 0121 ft. lbe. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 TFPI7I Paw Sofe SPRVJKLER FRESH (S.. Nate 8) K TYPE TEMP. BULB NATURAL CHROME "* WI'UTE" LEAD - UQUID BRASS I COATED PEN 136F/57'C Orange Deff 155°F/WC Red (TYfl31) 1,2,3,4,5,8,7 1,2,3,5 i 175F/WC Yellow UPRIGHT 200°F/93'C Green 58 (TY3131) 266F/141C Blue 1P2 NPT 136°F/57'C Orange REUSED 1550F8°C Red PENDENT (Iv1r 175°F/WC yejow 1,2,4,5 N/A Flgia'.B 200°F/C Green 135°F/570C Orange RECESSED 155°F/WC Rid PENDENT 1,2,3,4,5 1,2,4,5 N/A (TY31)' 1750F179°C Yellow ROM lO 200°FrC Green 135°F/ETC Orange PENDENT 155°F/6rC Red (TY4231) 1,2,5 .d 175°F/799C Yellow ______ 1, 2. 3, 4, 5, 6. 7 UPRIGHT 200°F,93'c Green 8.0 (TY4131) 288°F/141°C Blue 3/4. NPT 135°F/ETC Green RECESSED 155°F/68°C Orange PBIDENT (TY428l 175°F/79°C Red 1,Z4.5 N/A Flgte11 200°F/93'C Yellow 135°F/57'C Orange REESS!D 1650F/EB°C Red PBEtff (Tf4281)" 175°F/79'C Yellow 1,2,3,4,5 N/A FIgure 12 200°F,3'C Green NOTES: 1.11 by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. LIsted by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) sm Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k4) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact lyon Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428.4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (I-PCB Ref. No. 094a106) as Quick Response Sprinklers Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL LIsted, the sprinklers are UL and C-UL LIsted as Corrosion Resistant Sprinklers. Where Lead Cooled Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1i2' NPT) or Style 40(3/4' NPT) 3/4' Total Adjusnent Recessed Escutcheon, as applicable. Installed with Style 20 (12' NPT) or Style 30(3(4' NPT) 1,2' Total Aus*msn* Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A. Not Available TABLE B LABORATORY LJST7A11616 AND APPROVALS 5.8 AND 8.0 K-FACTOR SPRINKLERS ftee S of S 2-11' DtA. 5/8±1/4 (73.0 ivit) 1 34' (1911 mm) (15,9±6,4 nn) 2-1/4' DIA. 1/4' (6,4 nn) FACE OF I uome SPRINtER _-PurrE RiThO 11 7 MOUNTING/ cl.OSURE SERIES i-&ir (33 J SURMCE/ ___ TY-FRB 13/18' (20.8 mm) FIGURES SERIES TV-PRO RECESSED PENDENT V.77H TWO-PIECE." INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR 1,2 INCH NPT 2-7/8' OIL (73.0 MM) I 3/4"(19,1nin) (15,9±6,4mm) - 2-1/4' DIA. 1/4 (8.4 MM) I FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE lAr I Irm FITTING .1 - ____________ 7 MOUNTING / SERIES i-lW SURFACE,/' C1 OW TV-FRB 3/4' (1961 mm) FIGURE 7 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT TFPI7I 2-7/8' DLA. (73.0 MM) i1'(13,7mm) r (12,7±3,2 nii) 2-1/4' oisi.. I 1/4' (9,4 nvn) I FACE OF I I MOUNTING' 8PRMGIR I IRTflNG lAr (3.2 mm) / MOUNTING ' CLOSURE SERIES ir mmJ sURFACE/ ___ Ty-FRO 1-I/il' (27,0 mm) FIGURES SERIES TY-FRB RECESSED PENDENT V.7TH TWO-PIECE f,2 INCH TOTAL ADJLISTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR 1,2 INCH NPT 2-7/8' OIL (MO MM) -j 2-1/4' DIA. I 1/r(12,lMM) 1/4' (8.4 MM) (57,2 MM) ?1 I MOUNTING FIGURES SERIES TY-FRB RECESSED PENDENT WITh TWO-PIECE 12 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR 112 INCH NPT (13,7±3,2 mm) FACE OF SPRINKLER FITflNG t \ - MOUNTING SURFACE Care and Maintenance The Sen.. TY-FRB Sprinklers must be maintained and serviced In accord- ance with the following Instructions: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down Me affected fire protection system must be obtained 1mm the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheoni which Is used to cover a clearance hole, may delay the time to sprinkler operation In a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the lactory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after Installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from Its bulb. (Ref. Installation Frequent visual inspections are rec- ommended to be Initially performed for corrosion resistant coated sprinklers, after the Installation has been com- pleted, to verify the Integrity of the cor- rosion resistant coating. Thereafter, annual Inspections per NFPA 25 should suffice; hover, Instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condl- TFPI 71 - 2-7/8 DIA. ES"," (73.0mm) 3/4'(19.1 MM) SPRINKLER PLATE FACE OF I uouima I (15,,4 mm) 2-1/4' DA. 1/4' (6,4 MM) I FITTING 1/8' MOUNTING SURFACE SERUM 1-114' (31,8 ,vvvi) CLOSURE WFRS 314' (19,1 mm) FIGURED SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT - 2-718' CIA. 518*1/4' (73,0 ,tr) 3/4' (19,1 ,yI) - (15.9±6,4 mm) - 2.1/4' DIA. J 1/4' (8,4 mm) SPRINKLER I I PLATE I FACE OF __ (672mm) -1 MOUNTING I FrrnNG ___ I I ____________ / MOUNTING / SURFACE/ CLOSURE SERIES 1-5118' (33,3mm w1r(20,8mm) FIGURE 11 SERIES TY-FRE RECESSED PENDENT WiTH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON &O K-FACTOR, 2/4 INCH NPT Pag• 7 of • 2-7/8' CIA. 1P2*W (73,0 mm) I 1I'Z(1Z7 nm) r (14742 mm) 21/4 CIA. 1/4 (6,4 mm FACE OF (57,2 nvn) ) I IMOUNTIdGI SPR lAr PLATE IRNO TTI / MOUNTING / SURFACE SERIES 1-1/V (31,8 mm) CLOSURE Tv-FRI 1'(95.4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1,2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON £8 K-FACTOR, 1,2 INCH NPT (73,0mm) 118" (12,7 mm) (12,7*3,2 mm) - 2-1/4' CIA. 1/4' (8,4 mm) FACE OF I (57,2 MM) MOIMTING SPRINKLER ' PlATE FITTING I I 1/8' (3,2mm) UI , MOUNTM '3 CLOSURE SERIES (33,3mm 1YFRB 1-1/W(37,omm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON £0 K-FACTOR, 314 INCH NPT don and the long term Integrity of the corrosion resistant coating, as It may be affected by the corrosive conditions present. The owner Is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices In compliance with this dccii- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), In addition to the standards of any other authorities having jurisdiction. The In- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END A USED FOR 118' NPT MODELS) WRENCH RECESS (END "9" USED FOR $'4 PFT MODELS) FIGURE 13 WTYPE $ SPRINKLER WRENCH local requirements and/or national codes. FIGURE 14 W- TYPE 7 RECESSED SPRINKLER WRENCH Page S of S TFPI7I P/N 57-XXX-X-XXX I MODEL/SIN I I RATING I KLER 330 2.8K UPRIGHT (112NPT) TY1I3I . r_WP" 136 135*F/5C 331 1 2.8K PENDENT (1/2'NPT) TY1231 1 NATURAL BRASS 155 155°FC 340 4.2K UPRIGHT (1mNPT) 1Y2131 4 WHITE POLYESTER 176 176'F/7C 341 4.2K PENDENT (II#NPT) TY31 3 WHITE (RALSOIO) 200 200°F/93°C 370 5.6K UPRIGHT (1 0NPT) TY3131 9 CHROME PLATED 286 2erF/1410C 371 5.61K PENDENT (1/2'NPT) TY3231 7 LEAD COATED 380 8.0K UPRIGHT (3/4'NPT) TY4131 - 391 8.01K PENDENT (314'NPT) TY4231 * Eastern Hemisphere sake only. TABLE C PART NUMBER SELECTION SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work- manship when paid for and properly Installed and maintained under normal use and service. This warranty will ax- pine ten (10) years from date ofship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, Improper Installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation In connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' U- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTiES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR POSE - Ordering Procedure lecal distributor for avaIl- abiN5i. ths nami. RIr li Sis Price Ust lir of Pitt Ntmitaii Sprinkler AssemblIes with NPT Thread ConnectIons: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendant or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table Q. Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 112 (Is MM) 31)1.10 chram. Plated ............m 56-7014-010 white Coated .............PIN 58-701-4-010 WM. RALBOIO' ........... P/N 58-701-3-010 Brasa Plited ..............PIN 59.701-2410 1/2' (15mm) 51)1.20 Chrome Plated ............PIN 5e-7064-01O Whit. Coated .............PIN 58-705-4-010 while RALSOIO' ...........P/N 58-105-3-010 Brass Plated ..............PIN 58-705-2.010 3/4' (20 mm) Style 30 Chroms Plated ............PIN 56-7054011 WhIs Coated .............PIN 59-705.4-011 Whie RAL601O. ........... P/N 65-705-3-011 Brass Meted ..............P/N 59-705-2-011 3/4' (20 mm) Style 40 Chrcm. Plated ............P/N 55-700+010 While Coated .............P/N 58.700-4410 While RALQO1O. ........... P/N 55-700-3-010 Brass Meted ..............P/N 59-700-2-010 Eastern HsmUphsr. sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Typ. 7 Sprinkler Wrench, P/N 56-850-4-001. TVfl SIRE PROOUC1'$. 461 North Cannon Avenus, Lanedak, Pennsylvania 19446 Lim 9 0 0 4 A = Total Hose Length. including Reducing Fitting and Special Shoulder Nipple ii WE NIKING SuppIyNet FPSJ - Technical Features Sizes Available: 38" (965mm) and 58" (1473mm) long. 1" Inlet. /2" or 3/4" outlet. Temperature Data : Maximum temperature : 300°F (149°C) * Pressure Data: - Maximum Working Pressure: 200 PSI / 14kgf/cm2 - Test Pressure: 1000 PSI I 70.31<9f/cm2 (burst) Connections: - Inlet: 1" NPT male thread or DN25 BSP male thread. - Outlet: /2 NPT female thread or 3/4" NPT female thread IMPORTANT TECHNICAL NOTES: Minimum bend radius: 3" (76 mm) Maximum number of bends per hose: 3 Friction Loss Data : c - Equivalent Length of DN25/1" Steel Pipe (including 2 bends) (VENF) - FPSJ 1000 = 34 ft. (10.4 meters) -FPSJ1500= 43 ft. (13.1 meters) Flexible Sprinkler Connection — FPSJ Physical Data Nominal Size Inlet Hose Length Outlet Sprinkler EWeight inch metric; Connection A (inch/mm) Reference Connection (lbs/kg) /2 NPT FPSJ1000-50 2.5/ 1.13 38.0/965 '/4"NPT FPSJ1000-75 2.6/1.18 N T I /2 NPT FPSJ1500-50 2.8/1.27 1 P - 58.0 /1473 '/4"NPT FPSJ-1500-75 2.9/132 1. DN25 I" NPT FPSJ1000B-50 2.5 / 1.13 38 / 65 .0 9 3/4" NPT FPSJ 1000B-7 2.6/1.18 I "8 P /2 NPT FPSJI500B-50 2.8/ 1.27 58.0/1473 '/4" NPT FPSJ1500B-75 2.9/ 132 Flexible Sprinkler Connection — FPSJ Materials List Item Description Material Specifications 1 Flexible Hose Corrugated AISI 316L / AISI 304 Stainless Steel 2 Slip Nut Brass C3771 BC 3 Reducing Fitting (Outlet) Galvanized Steel SPPS 4 Special Shoulder Nipple (Inlet) Galvanized Steel 1 SPPS 5 Reducing Nipple Clamp & Bolt Galvanized Steel SS41 6 Bracket and Clip Assembly #1 Galvanized Steel SS41 7 Sprinkler Support and Cross Bar Assembly Galvanized Steel S541 8 Bracket and Clip Assembly #2 Galvanized Steel SS41 Worldwide Fire Protection Flexible Sprinkler Connections I FPSJ . www.vikingcorp.com ., . or. kw,) S, 01*1,, 'II m.'t L'd it Cl I, 01 1 or., Crir,h ED Installation Instructions LW 0 (D 0 NIKJNG* SuppIyNet FPSJ Step 1: Insure the proper size hole has been cut into the ceiling tile at specified location. Install the special shoulder nipple into the line tee using the NPT threaded end. Make sure that the arrow and shoulder of the nipple are both pointing toward the direction of the sprinkler. Apply a non-hardening thread compound or Teflon tape to the male threads of the nipple. Make up the nipple with a pipe wrench for a leak-tight connection. Step 2: Install the appropriate frame style sprinkler head to the special reducer fitting on the flexible sprinkler connection. (Note: Flush and Concealed sprinklers cannot be installed before the assembly is installed into the sprinkler support.) Apply a non-hardening thread compound or Teflon tape to the male threads of the sprinkler. Tighten the sprinkler to the special reducer end of the flexible sprinkler reducer with the appropriate sprinkler head wrench. Hand tighten slip nut to reducer. Step 3: Connect the flexible sprinkler connection to the shoulder nipple - check for shoulder and arrow direction. Do not use any joint compound or thread compound on the fine threads of the shoulder nipple. Tighten the slip nut on the flexible connection to the shoulder nipple by hand (see cautions). The nipple and flexible connection are designed to seal in this fashion. Connect the sprinkler connection to the special reducer Cautions - Slip Nut must be tightened by hand. Excessive force can damage the 0-ring. - Repeated bending of one portion of flexible connection before installation may cause breakage or loss of resisting pressure. - Special shoulder nipple is composed of stainless hose and must not fitting by hand. Do not over tighten! Step 4: Attach the bracket and clip assembly, along with the sprinkler support and cross bar to the ceiling grid by hand using wing bolts provided. (Note: Bracket and Clip Assembly #6 is intended for use with pendent and recessed pendent frame style sprinklers. Bracket and Clip Assembly #8 is intended for use with Flush and Concealed style sprinklers.) Do not fully tighten wing bolts on the bracket and clip assembly until the sprinkler support is centered over the hole in the ceiling tile. Step 5: Install the flexible sprinkler connection assembly including the frame style sprinkler into the sprinkler support and adjust the assembly until the proper sprinkler location below the ceiling is obtained. Tighten the wing bolt in the sprinkler support and recheck wing bolts on the bracket and clip assembly for tightness. For Flush and Concealed sprinklers, do not install the sprinkler until after the drop has been inserted into the sprinkler support. Step 6 : Test the system for leaks per the Hydrostatic Test Procedure in the applicable Edition of NFPA 13. Note : This product is designed to be installed in accordance with recognized installation standards, such as NFPA 13 be used as a ground for welding. - When connecting the flexible connection assembly to the sprinkler piping, connect the nipple to the 0-ring first: then connect it to the sprinkler reducer. - For use in heated areas only. 9 0' 9 0 0 S., Parsley Consulfing Engineers 50 West 9th Avenue, Suite IL Escondido, California 92025.053 T1k011 (760) 745-6181 F..(760) 715-0537 October. 13, 2006 Robert Ledesma City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Altium, Palomar Concours e O n e , C a r l s b a d , C A Dear Mr. Ledesma: We have reviewed the submittal as prepared by Lindley F i r e . Based on our review it is our opinion that the submi t t a l i s i n s u b s t a n t i a l c o n f o r m a n c e w i t h t h e applicable codes and standards in force at this time, inclu d i n g l o c a l a d o p t e d o r d i n a n c e s . Further submittal should not be required. We had no c o m m e n t s . Sincerely, PA EY CONSULTING ENGINEERS enneth W. agone9'ET Office Manager End (1) Working Drawings - 3 sets Note A COPY of this letter has been transmitted via fax to Lindley Fire on October 13, 2006