Loading...
HomeMy WebLinkAbout3207 GREY HAWK CT; ; AS060252; Permit11/7/24, 4:11 PM AS060252 Permit Data City of Carlsbad Sprinkler Permit 3207 GREY HAWK Job Address: CT Permit Type: SPRINK Parcel No: 2210150100 Permit No: AS060252 Status: PENDING Applied 10/18/2006 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: PALOMAR CONCOURSE ONE, STE 110 TI FIRE SPRINKLER INSPECTION Applicant: LINDLEY FIRE PROTECTION 2220 E VIA BURTON ANAHEIM CA 714-535-5761 Owner: CONCOURSE ONE LLC 9820 WILLOW CREEK RD #400 SAN DIEGO CA Fees ($) H Add Fees ($Total ($)PBalance RiT 60 0 60 0 about:blank 1/1 LINDLEY FIRE PROTECTION Co. 2220 E. VIA BURTON ANAHEIM, CA LINDLEY FIRE PROTECTION FIRE SPRINKLER HEAD SPECIFICATION SHEETS 2220 E. Via Burton Anaheim, California 92806 (714)535-5761 FAX (714)535-0576 California • Nevada • Oregon • Oklahoma • Arizona 1Y3231 - Pendant 5.61K, 1/2-NPT 1Y4131 - Upright 8.0K, MOW TY4231 - Pendant 8.0K, 314NPT Technical Data tqCO/ Fire & Building A Products Custom Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Tel: (414)570-50001(800) 558-5236 Fax: (414) 570-5010/ (800) 877-1295 Series "FRB —28,4.2,5.8, and &O K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8,4.2, 5.8, and 8.0 K-factor, Upright and Pendant Sprinklers described In this data sheet are quick response - standard cover- age, decoratIve 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendant Sprinkler, where ap- plicable, Is intended for use In areas with a finished ceiling. It uses either a two-piece Style 10 (112 Inch NPT) or Style 40(3/4 Inch NPT) Recessed Es- cutcheon with 112 inch (12,7 mm) of recessed adjustment or up to 3/4 Inch (19,1 mm) of total adjustment from the flush pendant position, or a two-piece Style 2D (112 inch NPT) or 19 30(3/4 Inch NP1) Recessed Escutcheon with 1/4 Inch (6,4 mm) of recessed adjust- ment or up to 1i2 Inch (12,7 mm) of total adjustment from the flush pen- dant position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- NPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING' that provides cautions i.th respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and In- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause It to operate prematurely. moapheree. Although corrosion resis- tant coated sprinklers have passed the standard corrosion teats of the appli- cable approval agencies, the testing Is not representative of all possible cor- rosive atmospheres. Ccnesquonft It Is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An Intermediate level versions of the Series TY-FRB Pendant Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed In Technical Data Sheet TFP780 Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval Information Including corrosion resis- tant status.) Maximum Working Pressure 175 pal (12,1 bar) Discharge Coefficient K 2.8 PM/psi1/2 (40,3 LPM/bar'12) K = 4.2 GPMsl1/2 (60,5 LPM/bar1 K = 5.6 GPMisi1/2 (80,6 LPMibarl'2) K = 8.0 GPM/e1112 (115,2 LPtvVbarl/Z) Temperature Ratings Refer to Table A and B WARNRJGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained In compliance with this document as well as with the applica- ble standards oldie National Fire Pro- tection Association, In adritlon to the standards of mW otiierautho,fUes hav- ing Jurisdiction. Failure to do so may lmp.I' tho p.ribnnance of ffi do. The owner Is responsible for maintain- ing their fire protection System and de- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted ie*h any questions. Model/Sprinkler Identification Numbers TY1I31 - Upright 2.81K, 1)2-NPT 1Y1231 - Pendant 2.8K, 1PNPT TY2131 - Upright 4.21K, 1120NPT TY2231 - Psndent 4.21K, 1/2-NPT 1Y3131 - Upright 5.51K, 1)2-NPT Paa. I of 8 JULY. 2004 YD4 7.1 ESCUTCHEON PLATE SEATING SURFACE T__ \- 2-1/4' (572 mm) 4 1-91W (39,7 mm) I L 49;4 SSP DEFLECTOR * 7/16' (11,1 mm) 112' ** NOMINAL MAKE-IN NPT PENDENT STYLE 100r20 RECESSED ESCUTCHEON -i WRENCH FLAT 2-7 .O mm) DIA. RECESSED PENDENT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature Is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. I I 8 Page 2ofS TFPI7I SSU* DEFLECTOR 7/16' S I I I 111 (11,1 mm) NOMINAL i _U_III 4 jJ11 MAKE-IN (55.6 mm) II 1 - _ 7 1 t2INPT** I I UPRIGHT CROSS SECTION 1-From 3-sewing 4-Bulb 8-O.A * Temperature rating ls Indicated ondeflectorocadjao.ntto 2- Bima Ass.mby 5- Compmulon 7- Bust*-ig orifice sm on frame Screw PIpe thread connectt one per ISO 7/1 can be provided an — reqUO& FiGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (T11131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT ESCUTCHEON 7/16'(11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON DEFLECTOR (11,1mm) 1 __ NOM*L 1 I i 7/16' MAKE-IN 2-3f16' WRENCH mm) FLATS 1i7NPT I 6*1 5 SSP DEFLECTOR * F 2-7/8' (73,0 mm) 01k PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-SsalWig 4-Bub '8.0 1 *116n0siau re" 16 indicated on delledw or ____ le 2- 8utn A.uiTtbly 5- Compression o,ffjca sent on frwne. Screw "Pip thread connectIons per ISO 7/1 can be provided on — re FIGURE 2 QUICK RESPONSE SERIES TV-FRO UPRIGHT (7Y2131) AND PENDENT (TV2231) SPRINKLERS 4.2 K-FACTOR, 1,2 WCH NPT Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Recessed Escutcheon: White Coated, Deflector .......Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) ........Bronze Physical Characteristics Frame .............Bronze Button ..........rass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont It? I (12,7 mm) NOMINAL I MAKE-IN - 4 2-1/4' (57.2 mm) 3/4NPT** I 8* P11 TFPI7I Page 3of ESCUTCHEON 7/1r (11.1 mm) STYLE 100r20 PLATE SEATING ** NOMINAL RECESSED __ SURFACE it? MAKE-IN ESCUTCHEON DEFLECTOR 1mm) I 2-3118' NFl 1 (55.6mm) III I I III NOMINAL I 4 MAKE-IN L I 21r 2 I 1-it? I (38,1 mm) WRENCH I (55,6 mm) : FLATS 2-it? (73.0 mm) DIA. -.1 it? NOT ** SSP DEFLECTOR PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION Frame S - Sesiblg 4-" 6- Deflector * T.mp.rature rating is Indicated on deflector or adjacent to Button Assembly 5- CompressIon orfte seat on frame. Screw "Pipe thread connections per ISO 7/1 can be provided on - mqu FIGURES QUICK RESPONSE SERIES 7Y-FRO UPRIGHT (7Y3131) AND PENDENT (7Y3231) SPRINKLERS 5.6 K-FACTOR, 1,2 hVCH NPT STYLE 30 or 40 RECESSED ESCUTCHEON ESCUTCHEON it? (12,7 mm) PLATE SEATING 3,4. ** NOMINAL SURFACE MAKE-IN NPT (6% 111 ' I 1-9116' (38,7mm) _,'••••• -- SSP DEFLECTOR * 2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION Fmm 3-Sea" 4- Bulb 6- D.flsctor * Temperature rating Is Indicated on deflector or adjacent to Button Assembly 5- CompressIon orifice seat on frwne. Screw Pips thread connections per ISO 7/1 can be provided on - requsat. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 9.0 K-FACTOr V4 54cM NPT Design Criteria The Series TYFRB Pendant and Up- right Sprinklers are intended for fire protection systems designed In ac- cordance with the standard installation rules recognized by the applicable Usting or Approval agency (e.g., UL Listing Is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of We Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon as applicable, Is to be used for recessed pendant installations. Installation The Series TY-FRB Sprinklers must be Installed In accordance with the follow- ing Instructions: TES Do not Install any bulb 4pe sprinkler If the bulb Is cracked or there Is a loss of liquid from the bulb. With the sprinkler Pa" 4o15 8P4ILER FV4S$H (S.. NOW 1) TYPE TEMP. BULB uoum NATURAL BRASS O*W= PLATED I Win r" POL 2.8 l/2• NPT PENDENT (TY1231) - UPRIGHT 1'FiWC Orange 1,2.3,5 Rid gF Green (TYII3I)8km RECESSED PENDENT cvvwir Agies 8 135'F/57C Orange 1.2.5 1WFiWC Red I75*FI79*C Yelow 200Fs3C Qam REESSEO Dff (rvisi) Rgur. I 135°F157°C Orange 166F/88°C Rid 1WF179°C Yellow 200N3C Green - 4.2 1/2' NPT PENDENT OY31) old UPRIGHT (7Y2131) 135'F/STC Orange 1,2 1550Fi8°C Red 175°F179°C Yetow 200°F/93°C Green 2WF/141-Cl Blue 135°F/57°C Orange RECESSED PENDENT ovir P9w. lsrFrna°C Red 1750F/79°C Yellow 200°FJ9rC Green RECESSED PRADENT' riir FigureS 135F/57C Orange 155'FsE8°C Red 17VF179C Yellow 200°F3°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. torusi in Canada (CAL) a Quick Response a Approved by Factory Mutual Research Corporation (FM) as Quick Response 5pm- klei*. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the epdn- Iders are Ut. and C-Ut. Usted as Corrosion Resistant Sprinklers. Installed with Style 10(112' NPT) or Style 40 (3/4 NPT) 3/4 Total Adjustment Recessed Escutcheon, as applicable. "Instilled with Style 20(1,2' NPT) or Style 30 (3f4' NPT) 112' Total Adjustment Recessed Escutcheon, U applicable. " Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TA ILE A LABORATORY LISTiNGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I inch NPT sprinkler joint should be oh- loki.d with a torque 0110 to 20 fte. (13,4 to 28,8 Nm). A maximum of 30 ft. be. (40,7 Nm) of torque is to be used to Install sps*ik!ere wi gq NPT con- nections. Higher levels of torque may distort the sprinkler Inlet and cause leakage or Impairment of the sprinkler. Do not attempt to make-up for Insuffi- cient adjustment In the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler llWiig to suit The Series TY-FRB Pendant end Up-rtØit Sprinkler, must be Installed in accordance with the following Instruc- tions. Step 1. Pendant sprinklers are to be Installed in the pendent position, and upright sprinklers are to be installed In the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 8 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 8 Sprinkler Wrench Is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30,or4o Mounting Piats,assppll- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler Into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Flgurs 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench Is to be applied to the sprinkler wrench fiats. Step C. After the calling has been In- stalled or the finish coat has been ap- plied. slide on the Style 10, 20, 30, or 40 Closure over the Series TY.FRB Sprinkler and push the Closure over the Mounting Plate until Its flange comes in contact with the calling. held horizontally, a small air bubble should be present. The diameter of the air bubble Is approximately 1/16 Inch (1,8 mm) for the 135°F/57°C to 3132 inch (2,4 mm) for the 286°F/1410C temperature ratings. A leak light 1,2 inch NPTspnnklerjoint should be obtained with a torque 017 to 14 ft/he. (9,5 to 19,0 Nm). A max!- mum of 21 ft. Ihe. 28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 34 TFPI7I Pag• 5 of S SPRB0LER FPMSH (S.. NoteS) IC TYPE TEMP. BULB UMM NATURAL BRASS I CHROME PLATED I WI'UTE' LEAD 1POLYESTEF COATED 5.6 1F2 PENDENT ____ CY3231) j UPRIGHT (1Y3131) 1F7'C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F/6rC Red im,,'irc 200°F/93'C Green 266'F/141C Bkie NPT OE __ __ (TY31 R9U116 135°F/SrC Orange 1.2.4,5 N/A 1550F/WC Red 175°F/790C Yellow 200°FISS'C Green 135°F/576C Orange 1,2,3,4,5 1,2.4,5 N/A REE PENDENT (TY2031)" Flgar. 10 155°F,C Red 175°F179'C Yellow 2000F/93C Green 8.0 3/4. PENDENT (TY4231) UPRIGHT (TY4131) 135°F/57'C Orange 1,2,5 1,2,3,4,5,6,7 155°F/6C Red mw 1750F/790C Yellow 200°F/93°C Green 286°F/1410C Bbe NPT 135°F/5TC Green 1, Z 4.5 N/A RECESS EC PDIDEW CTY423IY Flgw. 11 1550F/6rc Orange 176F/7YC .. 23°C Yellow 136°F/57'C Orange 1,2,3,4,5 N/A RECESSED PO4DENT (rf423i FIgure 12 155'FirC Red 175°P/79'C Yellow 200°F/93C Green 1.11 by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canade (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention CertifIcatIon Board (LPCB Ref. No. 0071004) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivIty of recessed sprinklers. S. Approved by the City of New 'tbrk under MM 364-01-E. 8. VdS Approved (For details contact 1'co Flaw & Building Products, Enschede, Nethertande, Tel. 31-53-4284444/Fax 3143-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 004aaD6) as Quick Response Sprinklers, Where Polyester Coated and Lead Coated Sprinklers are noted to be UI and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. White Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1 /2' NPT) or Style 40 (3f4' NPT) 3/4 Total Adjusnent Recessed Escutcheon, as applicable. Insudlad with Style 20 (liT NPT) or Style 30 (314' NPT) liT Total Auetois.1 Reoaed Escutcheon, as applicable Frame and Deflector only. Listings and approvals apply to color (Sp.ciel Order). N/A. Not Available TABLE B LABORATORY LI5I7NGS AND APPROVALS 5.5 AND 8.0 K-FACTOR SPRINKLERS P"e S of S L 2-71' DIA. (73,0 mm) 3/4' (loll ,,m,) (15,,4MM) 2-1/4' DIA. I 1/4'(6,4n) FACE OF IMOt4flNGI SPRIMER FffTING FrrnNG 'EI / MOUNTING / CLOSURE SERIES i-Mi' (33,3 TY-FRB 13/ii' (,6 mm) FIGURES SERIES TY-FRB RECESSED PENDENT WITH iWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2,8 K-FACTOR, 1,2 INCH NPT 2-71' DIA. - 51*1/i' I (73,0MM) (15,1 mm) - (15,,4mm) 2-114'DIA. 1/i' (8.4 MM) I FACE OF (57,2 mm) J MOUNTiNG I SPRINKLER PLATE I FITTING ___ _______ SURFACE I - MOUNTING SERIES 1-l/41$ mm)I CLOSURE ri-na 34 (15,1 tim,) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1,2 INCH NPT W114 71 2-7/6' CIA. (73.0 MM) 12' (12,7 n) I (12,7t3,2MM) _ 2-1/4' CIA. f 1/4'(6,4rivn) I FACE OF F7,2 mm) MOUNTING I l8PRI1. I L.—PLAIE FflTNG -cri 11' 7 MOUNTING / CLOSURE SERIES 1i' mmi SURFACE/ Ty-FRB i-ins' i,o mm) FIGURES SERIES 7Y-FRB RECESSED PENDENT *7TH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR 1,2 INCH NPT 11*1/6' (1Z73.2 mm) FACE OF SPRINKLER FITTING t \ - MOUNTING SURFACE : FIGURES SERIES TY-FRB RECESSED PENDENT WITH i100-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCU1HEON 4.2 K-FACTOR, 112 INCH NPT 271' CIA. .1 (MO MM) I 1/2'(12,7nmi) 2-1/4' CIA. I 1/4' (6,4 mm) I (S7.2 mm) MOUNTING 17-11 L- PLATE Care and Maintenance The Series TV-FRB Sprinklers must be maintained and serviced In accord- ance with the following instructions: vjj Before closing a fire protection system main control valve for maintenance work on the fire protection system that itcontrols, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon; which Is used to cover a clearance hole, may delay the lime to sprinkler operation In a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with asoft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after Installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. installation Frequent visual Inspections are rec- ommended to be Initially performed for corrosion resistant coated sprinklers, after the Installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual Inspections per I4FPA 25 should suffice; however, Instead of In- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I . 2-7/8' DIA. - (73,0 nmi) 3/4' (19,1 ,vw,i) (I 5,9A.4 mm) - 2-1/4' 01k 1/4 (8,4 n) FACE OF MOtRd11NGl SPRINKLER PLATE FtT1NO lAr MOUNTING/ SERIES 1-1141 (31,8 mm) SURFACE/ I CLOSURE rv.PRI 3/4' (19.1 mm) FIGURE 9 SERIES TV-FRO RECESSED PENDENT WITH TWO-PIECE 34 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON £8 K-FACTOR 112 INCH NPT - 2-7/8' DIA. - 5/8*114' (73,0 mm) 3/4 (19.1 MM) (15,,4 mm) 2-1/4' 01k 1/4' (6.4 mm) FACE O (672 mm) I MOUNTiNG I F SPRINKLER I PLATE FrrnNo .1 - ____________ / MOUNTiNG / SURFACE/ CLOSURE SERIES 1-5/18(33,3mm) tY-FAS 13llr(20.emm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE $4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON £0 K-FACTOR 3/4 INCH NPT POW of S 2-7/8'DIA. (MO MM) I 1/Z(1L7mm r (12.7±32 mm) 2-1/4' fX. I 's" (3,4 ITI1) I I .-i= OF 672 mm) 1 1 MOUNTiNG ISPRINI0.ER PI ATE IFrrnNG 1/8'I 71 / MOUN11NG SURFACE / / SERIES 1-1/4' (31$ mm) CLOSURE TY.FRS 1'(0,4 ffim) FIGURE 10 SERIES fl'-FRB RECESSED PENDENT WITH 7W0-PIECE 12 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON £5 K-FACTOR 112 INCH NPT 2-7/8' 01k (73,0 mm) - 1/2' (12,7 mm) 2-1/4' 01k J 1/4' (8.4 nn) I (67.2 MM) I MOr.?jNGI FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 12 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON £0 K-FACTOR, 3/4 INCH NPT 1/2*1/8' (13,7±9,2mm) FACE OF SPRINKLER FrrnNO I \ - MOUNTINGI SURFACE CLOSURE SERIES 1Y-FRB lion and the long term integrity of the corrosion resistant coating, as It may be affected by the corrosive conditions present. The owner Is responsible for the In- spection, testing, and maintenance 01 their fire protection system and de- vices In compliance with this docu- ment as well as with the applicable standards of the National Firs Protec- tion Association (e.g., NFPA 25), In addition to the standards of any other authorities having jurisdiction. The In- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler Systems be Inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (EM) A USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' ?Fr MODELS) FIGURE 13 V/-TYPES SPRINKLER WRENCH local requirements and/or national codes. wPj!NCN RECESS PUSH WRENCH IN TO ENSURE ENGAGEMW WH SPRINKLER WRENCHiNG AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Pag• B of B TFPI7I P/N 57 - XXX - X - XXX I MOOEIJSW4 I I RATING. I SPRINKLER 330 2.8K UPRIGHT (12'NP1) 1Y1131 1 135 135F/5rC 331 2.8K PENDENT (1t214PT) TY1231 I NATURAl. BRASS 155 155F,8'C 340 42( UPRIGHT (1DPT) 1Y2131 4 WHITE POLYESTER 115 175Ff7rC 341 4.( PENDENT (1/2'NPT) TY31 3 WHITE (RAL9010)' 200 200°MS°C 370 5.8K UPRIGHT (IPZNPT) V(3131 9 CHROME PLATED 288 28VF/141C 371 5.8K PENDENT (1/2'NPT) TY3231 7 LEAD COATED - UPRIGHT (314'NPT) 1Y4131 - :3997 8.0K 1 8.0K PENDENT (314'NPT) 1Y4231 Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TV-FRB PENOENTAND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work- manship when paid for and properly Installed and maintained, under normal use and service. This warranty will ex- pire ten (10) years from data of ship- merit by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by nershIp with Tyco Fire Products or for products and components which have been subject to misuse, Improper installation, corro- sion, or which have not been Installed, maintained, modified or :epalred In ac- cordance with applicable Standards of the National Fire Protection Aseocla- don, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Firs Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or Inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' U- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE MI LIEU OF ANY AND ALL OilIER WARR*NTIER EXPRESS OR IMPuFa INCLUDING WARRANTIES OF MFRCHANTARIIJT'AND FIT. NESS FOR A PARTICULAR PIJR- Ordering Procedure local distributor for avail- abmPiOralk . th. nasa. Refer it the Pdc. Lid for Pail PMai*sss. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TV-FAR (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2' (15mm) Style 10 chrom. Plated ............PIN 51-701-9.010 Whb Coated .............P/N 56.701-4-010 Whts RALSOIO' ........... P/N 51-701-3.010 Brasa Pitted ...............P/N 61-701-2.010 1/2' (15mm) Style 20 Chrome Plated .............PIN 51-706-9.010 White Costed .............P/N 56-705.4410 White RALSOIO' ...........P/N 58-705-3-010 Brass Rated .............. P/N 56-705.2-010 3/4' (20 mm) Style 30 Chrome Plated ............P/N 59.705-0.011 Whk Coaled ............. Pm 51-706-4-011 Whit. RALSO1O. ........... P/N 56-706-3.011 Brass IS ..............PIN 58-705-2-011 3/4' (20 mm) Style 40 Chroms Plated ............PIN 56-700-0.010 WNW Coated .............PIN 56-7004-010 Whit. RALOIO' ...........P/N 50-700-3.010 Brass Pitied ..............PIN 30.700-2.010 Eastern - sales only. Sprinkler Wrench: Specify: W-Type 8 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TVn FIRE PRODIJCTS. 461 North Cannon Avenue, Lanedale, PennsylvanIa 19448 A = Total Hose Length, including Reducing Filling and Special Shoulder Nipple 9 9 0 0 NIKJNG4 SuppIyNet FPSJ Technical Features Sizes Available : 38" (965mm) and 58" (1473mm) long. 1" Inlet. /2 or 3/4" outlet. Temperature Data : Maximum temperature : 300°F (149°C) Pressure Data: - Maximum Working Pressure: 200 PSI / 14kgl/cm2 - Test Pressure: 1000 PSI / 70.3kgf/cm2 (burst) Connections: - Inlet: 1" NPT male thread or DN25 BSP male thread. - Outlet: /2 NPT female thread or 3/4 NPT female thread IMPORTANT TECHNICAL NOTES: Minimum bend radius: 3" (76 mm) Maximum number of bends per hose: 3 Friction Loss Data: UL c UL - Equivalent Length of DN25/1" Steel Pipe (including 2 bends) (VENF) - FPSi 1000 = 34 ft. (10.4 meters) - FPSJ 1500 = 43 ft. (13.1 meters) Flexible Sprinkler Connection — FPSJ Physical Data rNomiria) Size Inlet hose Length Outlet Sprinkler Weight1 Reference inch metric Connection A (inch/mm)1 Connection (lbs/kg) I'2 NPT FPSJ1000-50 2.5/ 1.13 38.0/965 3/4"NPT FPSJ1000-75 2.6/ 1.18 1" NPT I /2" NPT FPSJ1500-50 2.8/1.27 58.0/1473 "/4"NPT FPSJ1500-75 2.9/ 1.32 DN __________ 1 25 /2" NPT FPSJI000B-50 2.5 / 1.13 38.0/965 1 BSP T I 3/4 NPT FPSJ100013-75 2.6 / 1.18 NPT FPSJ1500B-50 2.8/127 14" NPT FPSJ1SOOB-75 2.9 / 1.32 Flexible Sprinkler Connection - FPSJ Materials List Lem1Descnpbon ' .Mer SpecIcations 1 Flexible Hose Corrugated AISI 316L / AlSl 304 Stainless Steel 2 Slip Nut Brass C3771 BC 3 Reducing Fitting (Outlet) Galvanized Steel SPPS 4 Special Shoulder Nipple (Inlet) Galvanized Steel SPPS 5 Reducing Nipple Clamp & Bolt Galvanized Steel S541 6 Bracket and Clip Assembly #1 Galvanized Steel SS41 7 Sprinkler Support and Cross Bar Assembly Galvanized Steel SS41 8 Bracket and Clip Assembly #2 Galvanized Steel SS41 I Worldwide Fire Protection Flexible Sprinkler Connections / FPS11 www.vikingcorp.com Mai,,da;,red for V,khig SrpptyNei by ?aradife fixius;ry lid. R f. i0 M000iaefi,r, daia,heeL Sper,i,00fioor ruhieof 0 hang.' wires,; 10;00,