3207 GREY HAWK CT; ; FA150044; Permit
11/7/24, 4:11 PM FA150044 Permit Data City of Carlsbad Fire Alarm Permit 3207 GREY HAWK Job Address: CT Permit Type: FALARM Parcel No: 2210150100 Lot #: 0 Reference No.: Permit No: FA150044 Status: ISSUED Applied 7/8/2015 Approved: 7/8/2015 Issued: 7/8/2015 PC #: Inspector: Project Title: CRB HEADQUARTERS CONNECT DUCT SMOKE DETECTORS FOR NEW HVACS TO EXISTING FACP Applicant: LOW VOLTAGE FIRE INC STEL 1930 WATSON WY VISTA CA 760-598-4110 Owner: CONCOURSE ONE LLC C/O LEE PACHECO 130 VANTIS #200 ALISO VIEJO CA Fees (JAdd'I Fees )1Total )1JBalance J 292 0 292 about:blank 1/1 11 FIRE ALARM SYSTEM "Y %1'0" Lci wt.àItcIge I n t — g r ci t s y s tol m s FIRE ALARMS SOUND • DATA I MEDIA SECURITY* CCTV S ACCESS CONTROL FIRE ALARM SYSTEM CRB SUITE #150 T.I 3207 GREYHAWK COURT CARLSBAD, CA. 92010 These parts havv, been reviewed fol apparent enirpliunee with the cuticle applicable codes and snaidards In tonce ur the jurisdictkm. The owner or contractor tna\ utrhe this review itt sniport ut an ipplicatiun for it hutidrire pernrnr tt nh the esliteuc untdersnanidtrtg hint this ret rest in ni tav CltC\ es he ins'ntcr 01 contractor or titer pie ssinal ettttirrcer or alchliect torsole respirnnrhnint 101 htit 1orttplianee whit satd codes and staitiards. nntiudinrt he hriildtitg code or m nny respottsnhtltv for lelicienteres. errors. rlttnsSlIts or treInnicitee in these plots whether or not noted in this review. REC( )M hi EN) APPRI )VA I. REC0N1 MEND API'IDVAL. AS Nt)TEI) 11 c)N/ LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 LowVa Itage ntograted systems PHONE: (760) 598-4110 FAX: (760) 598-4107 MATERIAL LIST PART DESCRIPTION MANUFACTURER CSFM LISTING ASD-PL2F SMOKE DETECTOR GAMEWELL, FCI 7272-1703:0121 D4120 DUCT DETECTOR SYSTEM SENSOR 3242-1653:0207 AMM-2F MONITOR MODULE GAMEWELL, FCI 7300-1703:0102 RTS-151 REMOTE TEST SWITCH SYSTEM SENSOR 7300-1653:0212 Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. CIO, C16#791832 email: info @ sdlvis.com 22",* Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Velociti® Series ASD-PL2F, ASD-PTL2F and ASB=PL2FR Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Ordering Information Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Analog, Addressable Photoelectronic Smoke Sensor (T' ASD-PL2F/ASD-PTL2F ASD-PL2FR Features Sleek, low-profile design Visual rotary, decimal switch addressing (01-159) Built-in functional test switch activated by an external magnet Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm* Optional relay, isolator, or sounder bases Low standby current Analog addressable communication Stable communication technique with noise immunity Optional remote, single-gang LED Indicator (RAIOOZ) Compatible with Gamewell-FCI analog addressable panels Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. An ISO 9001-2000 Company SIGNALING & FM <S> MEA LISTED APPROVED Approved S1913 3023594 219-02-E Vot.Vl 12721703:0121 GAMEWELL-FCl 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 02011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0617 Rev. I page 1 of 2 Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: 4.0" (10.2 cm) square box 3.5" (8.9 cm) or 4.0(10.2 cm) octagonal box Single-gang box (except relay or isolator bases) With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box With B224RB or B224B1 base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications ASD-PL2F, ASD-PTL2F, ASD-PL2FR: Dimensions: 2.1" (5.1 cm) height Diameter: 4.1" (10.4 cm) installed in the B501 base 6.1" (15.5 cm) installed in the B21OLP base Shipping Weight: 5.2 oz. (147 g) Operating ASD-PL2F: Temperature: 32° F to 120° F (0° C to 49° C) ASD-PTL2F: 32° F to 1000 F (0° C to 38° C) UL®-Listed 0-4000 ft/mm. (1,219.2 m/min.), Velocity Range: suitable for installation in ducts. Relative 10-93% (non-condensing) Humidity: Thermal Ratings: Fixed-temperature setpoint 135° F (57° C) Electrical Specifications Voltaae Ranae: 15-32 volts DC oeak andby Current: (max. avg.): .0003 A 24 VDC (one communication every 5 seconds with LED blink enabled) aximum Alarm- [urrent: .0065 A @ 24 VDC (LED) lit). Bases and Options B501 Plug-in sensor base without flange Dimensions: 4.1(10.4cm) diameter B2IOLP Flanged mounting base Dimensions: 6.1" (15.5 cm) diameter B2IOLPBP Flanged mounting base bulk pack Dimensions: 6.1(15.5cm) diameter B224RB Plug-in sensor base with auxiliary Relay Base relay, SPDT, rated 2 amps @ 30 VDC (resistive) Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay I Form C contact UUCSA Rating: 0.9 A @ 125 VAC, inductive 0.9A@ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions: 6.1" (15.5 cm) diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions: 6.875" (17.5 cm) diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions: 6.875' (17.5 cm) diameter RAIOOZ Remote LED Annunciator BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203)484-7161 • Fax: (203) 484-7118 9020-0617 Rev. I page 2 of 2 www.gamewell-fci.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17272-1703:012'I Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds (204) 484-6124 Fax (203) 484-7309 Email: brian.reynoldshoneywell.com DESIGN: ModelsIASD772FI ASDPL2FR*, ASD-FILTREXF, ASD-PTL2F, and MCS-ACCLIMATE21F photoelectric smoke detector. Models ASD-PL2F and MCS-ACCLIMATE217 employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is JQI approved for use in lieu of a required heat detector. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models ASD-PL2F and ASD-PL2FR are also approved for installations inside System Sensor duct detector housing DNR (OSFM Listing No. 3242-1653:209) and DNRW(OSFM Listing No. 32421653:210)*. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. FORMERLY: 7272-1209:160 and 7272-0694:263 XLF: 7272-1653:0123 *Rev. 01-28-2010 fm r This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR D4120 Duct Smoke Detector The InnovairFief Series are the only duct smoke detectors flexible enough to fit configurations from a -. square to rectangular and everything in between Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3A-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing lnnovair products, including remote accessories Agency Listings & <~> 0 LISTED APPROVED S911 3033744 7272.1653:0203 The InnovairFiex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFIex housing provides ample wiring space, a 3,4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 lnnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access esUReset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFIex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. lnnovairFlexTM Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex°° D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications 16 i"W* Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature flange: D4120 & D4S: -4° to 158°F (-200 to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & D4S: -22° to 158°F (-30° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/sec) Electrical Ratings Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max. 270 pF max. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with RTS151) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Alarm initiation contacts: 2.OA @ 30 VDC (resistive) Alarm auxiliary contacts: 10A @30 VDC (resistive); 10A @250 VAC (resistive); ½ HP @240 VAC ; 1/4 HP @ 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 2.OA @ 30 VDC (resistive); 2.OA @ 125 VAC (resistive) 'Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA151 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS151/RTS151KEY 0mA/12mA n/a 112 mA Max. I RTS2/RTS2-AOS 3.0mA max 16 mA Max. with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed b releasing the front or rear lockina tab /fr1nt lockina tab shown below riciht). r - . Alk ---,-,..- j --- j .VDSOO5OO I LAST DETECTOR IN THE LOOP NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Wiring for 4-wire Duct Smoke Detector and Accessories ------------ I POWER INPUTS (NOTE 1) I 4VACIDç F120 VAC I,& &I 910 I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB JN 1 * , N SUPERVISORY CONTACTS I (NOTE 3) sue.Q. sup ------------ FIRST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-60Hz. 120VAC Power Inputs accept only 120 VAC 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. I POWER INPUTS (NOTE 1) I I 04V F1 910 OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB I JN N I SUPERVISORY CONTACTS I (NOTE 3) EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER '1 Important Notes on 2:1 Sensor-to-Power Capability 2:1 sensor-to-power capability is not available for all InnovairFiex models. The feature is only available on the 04120 4-wire conventional models. 2:1 sensor-to-power capability can be enabled using one 04120 and one 04S, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the lNT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX— terminal on unit 1 to the INT/AUX- terminal on unit 2 and so on. Up to 5004120 units, 50 04P120 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three 04P120 units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100AC0Cs or 27 04120 units. * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. HVD000500 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. _ ISMOKE L RTS151 UL S4011 RTS1S1 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 ------------ r All, _ TT RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS Ordering Information Part No. Description 04120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only D4P120 4-wire photoelectric power board component only, 24 VAC/DC, 120 VAC 2051 4-wire conventional photoelectric sensor head OST1 Metal sampling tube duct width up to lft (0.3m) OST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 f (0.6 to 1.2m) DST5 Metal sampling tube duct widths 4 f to 8 f (1.2 to 2.4 m) OST10 Metal sampling tube duct widths 8 f to 12 ft (2.4 to 3.7 m) APA151 Remote annunciator with piezo alarm OH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 f (0.3m) M02-04-00 Test magnet MHR Mini Horn, Red MHW Mini Horn, White P48-21-00 End cap for metal sampling tubes RA100Z Remote annunciator alarm LED FITS 151 Remote test station RTS151 KEY Remote test station with key lock RTS2 - ADS Multi7signaling accessory with add on strobe -W EA4 3825 Ohio Avenue • St. Charles, IL 60174 ©2Ol2 System Seso,. Phone: 800-SENSOR2 • Fax: 630-377-6495 Prod ispecificafims~bjecttocharigewthmi sysim oV cm VLI www.systemsensor.com ivs0000 • I112 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 13242-1653:02071 Page 1, of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Model D41201 D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD4I2OX, LD4I20H, D45, D4P120, CD4P120 LD4P120X, LD4PI20H, TD4C, PD4120, YD4120, YD4P120, and AD4P120 four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 2D51 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4C LD412OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C, LD4I2OX, LD4120H, LD4PI20X and LD4P120H *do not have 120 VAC rating). INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-27-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 17300-1653:02121 Page 1 of I 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com ModelslRTS1511 RTS151 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. Refer to the installation manuals. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: - APPROVAL: 04-03-09 bh __ C, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division OF t s~ 'gighhh, Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Velociti® Series ANIN1=21' Description The Gamewell-FCI VelocitiO Series, addressable monitor module AMM-21F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry con- tacts may be made addressable when connected to the AMM-217 module. The VelocitiO Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-217 module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterfiow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Velocit® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Addressable Monitor Module AWN Features Compact size allows easy installation Class B, Style B, initiating circuit 40 Ohm line resistance for each initiating device circuit Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% (non-condensing) End-of-Line Resistance: 47K ohms Dimensions: 1.3' Lx 2.5' WxO.5' 0 (3.3x6.4x 1.3 cm) Ordering Information Part Number Description AMM-2F Addressable monitor module, single circuit, Style B, Class B SIGNAUNG ®<E>MEA LISTED APPROVED Appnoved S1949 3023594 227.03-EVOLIV 1300-1703:0102 'iso onni GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ,,©2013 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. E page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: 17300-1703:01021 Page 1 of 1 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds (204) 484-6124 Fax (203) 484-7309 Email: brian.reynolds2honeywell.com Models AMM-4, *AMM..4F AMM-2 and FAMM-27 monitor modules and Models AOM, AOM-2, AOM-2R, *AOM..2RF AOM-25 and *AOM..2SF control modules. Refer to listees data sheet for detailed product description and operational considerations. In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules FORMERLY: 7300-0694:178 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division _ SYSTEM RECORD OF COMPLETION [ Ji This form is to be completed by the system installation contractor at the time of system acceptan and a)JJr RI It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. [ fl Attach additional sheets, data, or calculations as necessary to provide a cone Me rd. JE 0 Form Completion Date: 8/26/2015 Supplemental Pages Attached PROPERTY INFORMATION Name of property: CRB, Grey Hawk Court Offices Address: \ 3207 Grey Hawk Court, Carlsbad, CA 92010 Description of property: B Occupancy, 2 Story, Fully Sprinklered Name of property representative: CRB USA Address: 2701 Loker Ave. West, Ste 130, Carlsbad, CA Phone: 626-319-1425 Fax: E-mail: Peter.Maricrbusa,com INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Low Voltage Integrated Systems Address: 1930 Watson Way, Ste L, Vista, CA 92081 Phone: 760-598-4110 Fax: 760-598-4107 E-mail: Mikea@sdlvls.com Service organization: Same Address: Phone: Fax: E-mail: Testing organization: Same Address: Phone: Fax: E-mail: Effective date for test and inspection contract: May 2015 Monitoring organization: National Monitoring Center Address: Phone: 1-800-662-1711 Fax: E-mail: Account number: A21-3026 Phone line 1: Means of transmission: Digital Communicator Phone line 2: Entity to which alarms are retransmitted: Carlsbad Fire Dept. Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system 10 Modification to existing system Permit number: FA1 50044 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: FCI Model number: 7100 4.2 Software and Firmware Firmware revision number. 7.1 43 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright 02012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 3) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 VAC Overcurrent protection: Type: Circuit Breaker Branch circuit disconnecting means location: HP2 5.1.2 Secondary Power Type of secondary power: (2)12VDC 1 3AH Batteries Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 5.2 Control Unit This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A G. CIRCUITS AND PATHWAYS Control panel amps: Amps: 20 Number: 9 In alarm mode (minutes): 5 Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line X B 0 Device Power Initiating Device NotificationAppliance Other (specify): REMOTE ANNUNCIATORS Location INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual _Pull _Stations Smoke Detectors Duct Smoke Detectors 11 Addressable Supervisory Photoelectric Heat Detectors Gas Detectors Waterfiow Switches Tamper Switches Copyright 02012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2 of 3) SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown 1 Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip INTERCONNECTED SYSTEMS IJ This system does not have interconnected systems. o Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: ,'r- c' Printed name: Ron Cinko Date: 8/25/2015 Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech Phone: 760-598-4110 12.2 System Operational Test This system as syecified herein has tested according to all NFPA standards cited herein. Signed: ------ Printed name: Ron Cinko Organization: Low Voltage Integrated Sys. Title: Fire/Life Safety Tech 123 Acceptance Test Date and time of acceptance test: \. Installing contractor representative: Ron Cinko Testing contractor representative: Ron Cinko Property representative: - Date: 8/25/2015 Phone: 760-598-4110 Copyright 5 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3 of 3) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household application and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. I Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of ny claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct J•V:fl operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division