HomeMy WebLinkAbout1953 DOVE LN; ; AS030224; Permit10/15/2020 AS030224 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS030224 Job Address: 1953 DOVE LN Status: PENDING Permit Type: SPRINK Applied 10/29/2003 Parcel No: 2150521500 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: LA COSTA GREENS OH AS PLAN CHECK & INSPECTIONS Applicant: Owner: REAL ESTATE COLLATERAL MANAGEMENT CO C/O LIZ LAYMAN! MORROW DEV 1903 WRIGHT PL #180 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 482.75 0 482.75 0 1/1 I M/jN7ERI/4"NL DATA SUBr"'ITTAL Lo Gosto Greens Building #1 - 153 Dove Lone GArisbod, GA LIFEGUARD FIRE PROTECTION, INC. 2005 TEF-1PLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92050 70-80-9997 • 7008004813 FAX Protection Design & Consulting —D No ExcetiOTiS Li With. Comntefl ts IZ4 T. M03ozz4- FILE copy DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTION Physical Properties 1ysic1 rope1 es U.S. Patent No. 4.989,635 • U.S. Patent No. 5.107.888 U.S. Patent No. 5,385,166 • U.S. Patent No. 5,226,441 Size of Mainline 2-1/2", 3, 4", 6, 8", & io U.S. Patent No. 5,392.803' U.S. Patent No, 5.503,176 Max. Working Pressure 175 PSI (1200 KPa) Hydrostatic Test Press. 350 PSI (2400 KPa) Temperature Range 320 F to 140° F (00 Cto 60° C) . End Connections Flanged ANSI B16.1 ' Class 125 Materials Main Valve Body Ductile iron Grade 65-45-12 Coating Fusion epoxy coated internal and external AWWA C550-90 MODEL 876V DOUBLE CHECK DETECTOR (Shown In vertical position) Shut Off Valves OS & V resilient wedge gate valves AWWA C509 Trim Bronze Elastomer Discs EPDM Spring Stainless steel MODEL 818!878V DOUBLE CHECK DETECTOR (Shown In standard orientation) Installation Views I I 18 man Grooved End 4-' FLOW Standard orientation (Model 876"1876V) Vertical orientation (Model 876V) * Note-Model 876 does not include grooved end coupling. Recommended minimum clearances from permanent structures *)r ease of testing and maintenance. Elf 1 Support isbed by customer) ,alve weight only. 8761876V Materials of Construction ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS I Body A536 GR 6545-12 8 Lower Spring Retainer B584 Alloy C83600 26 Gasket EPDM ASTM D2000 2 Cover A536 GR 6545-12 9 Spring Stem 30455 35 0-ring EPDM ASTM D1999 2.1 0-ring EPDM ASTM D2000 9.1 Elastic Stop Jam Nut 18-8 SS 35.1 Back Up Ring Acetal Resin 2.2 Cap Screw Plated Steel 10 Spring A13 Type 631 SS 36 Cover 8584 Alloy C83600 2.3 Hex Nut Plated Steel 10.2 Spring Shim Acetal Resin 40 Bail Valve B584 Alloy C83600 2.5 Cover (w/o holes) A536 OR 66-45-12 10.3 Spring Shim Acetal Resin 41 Nipple Brass 3 Seat Ring B524 Alloy C83600 11 Spring Guide B130 Alloy C22000 42 Gate Valve (OS&Y) AWWA C509 3.1 Gasket EPDM ASTM D2000 12 Upper Spring Retainer B584 Alloy C83600 43 Bulkhead Fitting 6584 Alloy C83600 4 Arm B584 Alloy C83600 12.1 Bushing Spring Stem Acetal Resin 43.1 Bulkhead Fitting B584 Alloy C83600 4.1 Bushing-Swing Pin Acetal Resin 13 Pivot Bearing - 8585 Alloy C83600 44 Bulkhead Fitting 8584 Alloy C83600 4.2 Swing Pin 304 SS 14 Flange Gasket Rubber/Fabric 45 Gasket EPDM ASTM D2000 5 Retaining Clip 302SS 15 Bearing Socket Acetal Resin 45.1 Gasket EPDM ASTM D2001 5.1 Retaining Clip 302 SS 16 Hex Jam Nut 18-8SS 46 Washer 836 Alloy 260 6 Check Disk (2-1/2 - 8) EPDM Coated OR. 45 Capscrew (10* Only) 18-8 SS 46.1 Washer B36 Alloy 260 Ductile Iron w/ type 17 Washer 302SS 47 Nut 8584 Alloy C83601 3045S 18 Flange Nut Plated Steel 47.1 Nut B584 Allloy C83602 Seal Disc (10* Only) Silicone ASTM D2000 18.1 Flange Nut Plated Steel 60 Identification Plate B36 Alloy C26000 6.1 Disc Holder (10* Only) ASTM A743 304 SS 19 Cover A36 Sti. Epoxy Coated 61 Identification Plate 836 Alloy C26000 6.2* Disc Retainer (10* Only) ASTM A743 304 SS 24 Bolt Plated Steel 62 Drive Screw Stainless Steel 6.3 Capscrew (10* Only) 18-8 SS 24.1 Washer Plated Steel 70 Clamp 876V Only AWWA C606 7 Load Pin 304S5 25 Bolt Plated Steel Not Shown 2 Note: The Model 876V is shipped in the standard (N-Shape) orientation as shown be qrooved end OS &Y Side View Model 876V Model 876V Standard Orientation Vertical Citaticn Dimensions Approximate El Net oS&Y OS&Y Size A B C OPEN F G H J K M (Lbs.) 2'12" 12112 2514 24'14 1618 1616 6114 111/2 31I2 1361.. 271I4 230 65 317.50 654.05 615.95 415.93 422.28 158.75 292.10 88.90 346.08 692.15 104.33 3" 121/2 2514 241. 22'4 16I.. 61/4 111/2 33/4 14'/e 281/. 30() 80 317.50 654.05 628.65 565.15 422.28 158.75 292.10 95.25 358.78 717.55 136.08 4" 14 27 /a 26I. 23'1. 1 P1 7 13 41/2 15'I2 31 330 100 355.60 708.03 679.45 590.55 450.85 177.80 330.20 114.30 393.70 787.40 149.69 60 16 321/4 321/4 301/.. 21Ii 8 13 51/2 18Ie 37114 520 150 406.40 819.15 819.15 765.18 547.9 203.20 330.20 139.70 473.08 946.15 235.87 8" 18'/2 371/2 361a 373/4 24% 9'/4 141/2 6/4 20I4 411/2 860 200 469.90 952.50 923.93 958.85 631.80 234.95 368.30 171.45 527.05 1054.10 390.09 10" 21 42'12 403/4 48 27'I2 10 15 8 24 48 1460 250 533.40 1079.50 1035.05 1219.20 698.50 254.00 381.00 203.20 609.60 1219.20 662.24 Weights do not Include risers or optional valve setter. Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances. Refer to Specification Sheet SS VS for details on valve setter. OLAIS -J p Application Non-Health Hazard Fire Spriikler Systems Flow Orientation Standard orientation is inlet flow vertical up, outlet flow vertical down. Vertical orientation is inlet and outlet flow vertical up. Options 0 Valve Setter with MJ x FL, MJ x MJ or FLxFL ends Agency Compliance Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California. ASSE (Std. 1048) ANSI/AWWA (C510-89) CAN/CSA (1364.5) FM* UL* cUL * Less gate not FM approved. Less gate not UL listed unless installed with UL listed gated valves. Model 876/876V Flow Curves I S S IS S Ii SI . 4. U son ..Sow S IS III II III II (II na - SI IS 55 55 SI SI SI A-Vertical orientation (model 876V) B-Standard orientation (model 876) FEBCO Backflow Prevention P.O. Box 8070- Fresno, CA 93747-8070 559 252-0791 • Fax: 559453-9030- www.cmb.Ind.com 55876V 0101 ovttd O1 cMB hdttfles. Inc. The 6" and 10" flow curves in the standard orientation include the FEBCO valve setter model 611. CMII IndwAdeli, Inc. 1dnl4 rriinra ISO 9001 Certified Schedu,em10"/Schedu1em40" Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1 0/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l',"- 8") pipe and Sch-40 (1"- 214") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. I Galvanized Pipe Schedule-I0/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: I4Specifications NPS Nominal I.D. WI. Wt. (H20 Filled) Pcs/ Wt/Lift (21) WI/Lift (24) WI/lift (25) In; mm In; mm Lbs/Fl; Kg/rn LbslFt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.049 1.680 2.05 70 21470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1V4 1.380 2.270 2.93 51 2.431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1/2' 1.610 2.720 3.61 44 2,513 2.872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2W' 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 [iSpecifications NJ'S Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lift (21') WI/lift (24) WI/lift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 lW 1.682 2.080 3.04 61 2.664 3,045 3.172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2 2.157 2.640 4.22 37 2.051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2W' 2.635 3.530 5.89 30 27224 2,542 2.648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1.951 2.230 2.322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Listed Approved Listed 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 11350 Norcom Rd.' Philadelphia, PA 19154 (800)882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqco/Flow Control ç; allied TUBE & CONDUIT ipe F aa/Dyi a-Flow® .Aigh Strength Steel Pipe- The original high-strength light wall sprinkler pipe with hydruJjcs superior to Schedule-10. Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Litt Wt/Lltt Wt/Llft NPS 1.0. N20 Filled Lift 21' 24' 25' X 1" 1.191 0.830 1.31 - 91 1583 1812 1888 *25 30.3 1,2 1.95 91 719 822 856 x 1 1/4" 1.536 1.059 :t.87 61 1356 1560 1615 32 39.0 1.6 2,78 61 615 703 733 x11/2" 1.728 1.667 2.71 61 2135 2440 2542 *40 43.9 2.5 4.03 61 968 1107 1153 x 2" 2.203 2.104 3.70 37 1634 1868 1946 *5056.03.1 5.64 37741847883 x 2 1/2" 2.703 2.564 5.10 30 1615 1846 1923 *6568.73.87.59 30733837872 3.314 3.387 7.18 19 1351 1544 1608 *8084.25.010.6919613700729 4.310 4.473 10M6 19 1784 2039 2124 *90109.56.716.16 19 809 925 963 X 6" 6.403 7.714 21.70 *150 162.6 11.5 32,29 Super Flo/Dyna-Flow pipe is manufactured to meet ASTM A 795 Type B, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Plo are. UL Listed, FM Approved and ULC Listed. Super Flo/Dyna-Flow pipe is the "original" high-siiength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. ~~I! Superior Hydraulics - With an inside diameter of up to 11016 larger than Schedule-40 and up to 7% larger than Schedule-ID, SuperFlo/ Dyna-Flow pipe hydraulics are exceptional. get I.D.s enable Super Flo/Dyna-Flow, ,Lid related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Super Flo/Dyna-Flow Hydraulic Data Tables." 10 1620 1851 1928 10 735 840 875 Lightweight and easy to install, resul.ting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. SuperFlo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and UN. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No .1—'cial process or equipment are needed fabrication and installation. ' allied 'RJÔE & CONDUIT A t 9 9 t0c Listed Approved Listed Super Flo/Dyn a-Flow is U'LJULC Listed for use With roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Super Flo/Dyna-Flow is now available "hot-dip"galvanized and has been specifically approved by FM for dry systems uses, Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. - Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mitt coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Customer ServIce: 1800-797-6210 Fax 708-339-1806 16100 S. Lathrop 11350 Norcorn Rd, 2525 N. 27th Ave. Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 65009 Submittal Data Sheet Super 407DynaThread5 Full Line Sch-40 Replacement Super -tO Dyna-Thread sprinkler pipe represents an engineering advncenieni for the sprinkler pipe industry. R combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Super 10/Dyna-Threads inside. diameter is up 10 16% knner than Sch-40 siving it superior hydraulics. Also, when used in combination with Dynu-Flow pipe. down Sizing Often occurs. Super 40/Dyna-Thread is fully listed ind approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Super 40/Dytta-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL (see CRR). The cottsisteiii quality of steel u-ed to make Super 40/Dna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Super 40/Dvnu-Thread is protected by a clean, durable mill courirtii for extended shelf file und eas paint application. With its increased strength and lighter weight, Supei-40/ [) na-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion F ixtuflee Ratio I C RR I is a UL. (Underwriters Laboratory) term fOr the estimated life expectancy of a pipe joint. This is bused on the calculated wall thickness at the base of the first exposed thread, t.ttnieil to he the weakest point of the pipe length. Super 40/Dyna-Thread and Sch-40 have the ,.ime calculated vLill thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T.Pipe More wall thickness at the thread (CRR= 1.00) gives Super 40/1Dma-Thread better life expectancy than lighttvall threadable pipe joints. Unlike liohtwall tlircitdablc pipe. Super 40/Dyna-Thread has no thread oattge warning. Super 401 [tyna-Thread is approved for standard hanger spacing (15 ft. O.Cj, can be used as earthquake si,av lraciny. and is safe to use as drops. Super 40/Dytta-Thread is safer to weld on than many zinc-coated lighiwall diteadable pipe products. Super 40/Dyna-Thread is more widely accepted tli:in lighiwall threadable where Sch-40 is specified. Spèifications & Approvals Supet-4f1/Dytta-Thtead pipe is timatiufttcrttted to meet: ASTM A 135, Grade A and is in compliance itli NFPA- 13. All sizes of Super 40/Dyna-Thread ate rated at 300 psi working pressure. Super 40/ [)vnu-Thread is UL and ULC Listed for wet, dry Mid pre-action sprinkler systems and FM Approved fur use in uret sstems. Super 40/Dyna-Thread can be hot-dip galvanized to meet FM requirement for dr .ysicn1a. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suti:ihle for all toll-grooved, and plain-end fittings. (See listing itt format ion). (LI M~ e Wwd Approvoi LiId Stamp Here' jt I. 'I Product Nominal Wt/Ft Wt/Ft PCs/ - Wt/Litt Wt/Lift Wt/Lift NPS ID. I-laO Fitted Lift 21' 24' 26' 1.080 1.330 1.75 70 1955 2234 2327 *25 27.4 2.0 2.60 70 887 . 1013 1056 x 1/4 1.408 1.870 24 51 2002 2288 2384 *32 35.8 2.8 3.78 5190810381081 1 1/2 1.639 2.290 3.22 44 2115 2418 2519 *4041.6 3.4 4.79 44959 10971143 x 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 4.irterican Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lighiwall and standard teall family aiproditcis although they have dilicrent names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dna-Flow and Super Flu are tlte same product as are Dyna Thread and Super 10. XL is manufactured with Exterior galvanized coaling. BLT is nianulactured with Black lacquer coating, Project: Sprinkler Contractor Date: Engineer: Specification Reference: System Type: Locations: Comments: Flow Data Friction Resistance TIie chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/20 elbow is appro2dnrntely one-half the resistance of a 450 elbow. Values of trod-sizes can be interpolated. ST 4ROOVED FIT : Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. <S9 Victaulic offers a broad line of fittings in sizes through 240 (500 mm) in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are 'supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These firtings are not intended for use wifh Victaulic couplings for plain end pipe (refer to page 55 for fittings available for plain end applications). Fittings are provided in various materials including malleable iron, ductile iron, steel or segmentally welded steel depending on styles and size. Fittings ,are painted orange enaii'iel with galvanized optionally available, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic..Flange& adapters, check disc clearance dimensions with I.D. dimension of fitting. Request 07.01. Alternate Materials Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 optionally available) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Request 17.04 for details Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 'I - 8' (25 - 200 mm). Request 21.03 or contact Victaulic for details. Alternate Styles EndSeal® 'ES" Fittings - EndSeal fittings are available in 2 - 12" (50 - 300 mm) for use with "ES' grooved pipe and HP-70ES EndSeal or FiroPTh couplings. "ES" fittings are painted green [or easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings' when ordering. Request 07.04 for infoimation on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) -- For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Bequest 25,03 or contact Victaulic for specific details. Pipe Pipe Inches/mm Equivalent Feet/wears of Straight Pipe inches/mm Equivalent Feet/wears of Straight Pipe - - 900 Elbows 450 Elbows Tees 90' Elbows 45° Elbows Tees No. 100 No. 110 No. 100 No. 110 No. 10 1½0 No. 11 1½D No. 10 1½0 No. 11 1½0 Now. Actual Sid. Long Sid. Long Nom. Actual Sid. Long Sid. Long Size Size Radius Radius Radius Radius Branch Run Size Size Radius Radius Radius Radius Branch Run 1 1.315 1.7 -. 0.8 - 4.2 '1.7 6 6.625 10.0 7.5 5.0 3.0 20 10.0 25 33:7 0.5 0.2 . 13 0.5 150 16113 30 2.3 15 0.9 76 30 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 6.500 9.6 -. 5.0 - 25.0 10.0 50 60.3 1.1 03 05 0.3 20 ii 6744: 1551 2.9 - 15 1 76 30 34: 3.000 4.3 -. 2.1 10.8 4.3 8 0.625 13.0 9.8 6.5 4.0 33.0 13.0 76.1 1.3 .. 07 . 33 I.3 200 :'19'i .40 3.0 2.0 1.2 101 40 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 Co 369 15 12 08 0.5 40 1.5 750 2.73.0 52 3.7 2.5 1.5 12.5 5.2 4 4500 6.8 5.0 3.4 2.1 160 3.8 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 100 1143 21 15 là Oil 40 2.1 300 323.9 6.1 4,4 30 16 15.2 61 '1/44: 4.250 6.4 -. 3.2 - 15.3 6.4 11 1°1.000 '1 23.0 If 18.0 60.0 17.0 106.0 1.8 09 47 20 :iso 3556 d 7.0 If s 1113 5.2 5 5.563 8.5 - 4.2 -. 21.0 8.5 16 16.000 ft 26.0 Ii 20.0 70.0 20.0 125 141.3 2.6 . 1.3 -. 6.4 26 400 406.4 ii 79 If 6.1 213 61 5/i.4: 5.250 8.1 - 4.1 - 20.0 8.1 18 18.000 ft 29.0 If 23,0 80.0 23.0 1330 25 - 1,5 6.2.7.5 454) 457.0 4 3.8 1 ?0 24.4 70 4: 5.500 8.5 - 4.2 - 21.0 8.5 20 20.000 It 33.0 II 26.0 90.0 25.0 139.7 16 - 1.3 6.4 2.6 500 508.0 ii 10.1 it 7.9 27.4 7.6 64: 6.250 9.6 -. 5.0 -. 25.0 10.0 24 24.000 ft 0.0 ft 30.0 30.5 34.0 159.0 2.9 . 15 . 76 20 600 6)0 1) Ii 122 iii 83 10.4 SI Contact Victaulic for details. 4:0.0, Dimension. 14 IP 041 GROOVED COUP.LJNGS,.,,, ................. .- 1. WmagMA"am Style 07 Zero-Hex® Rigid Coupling 2-12 Sizes The unique angle-pad design of ZeroFIex® Style 07 adjusts to standard pipe and roll or cut groove tolerances, positively clamping the pipe to resist flexural and torsional loads. Wider key section tills more of the groove area. Request 06.02. Style 77 Standard Flexible Coupling Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. Sizes 3/4 -12" (20- 300 mm) are two-piece housings. Sizes 14 - 22" (350 - 550 mm) are cast in four identical segments, with larger sizes cast in six segments. Request 06.04. 11 _.Y -------,l 24" Size --Y ---" - Z - 1 14- 16" Sizes 18- 24" Sizes J LZI ,..; FO// ,.x -0 3/~ - 12" Sizes 14- 22" Sizes Nom. Max. Work Press. Dimensions - Inches/mmSize WgtEach X V Z Inches/nm P51/kPa Lbs./lq 750 2.45 4.13 1.88 1.6 02 10i 46 14 Ff4 750 2.60 4.00 1.88 1.6 iii> it)? 1½ 750 2.94 4.81 1.88 - 1.6 Ill ii 142 '131 2 750 3.19 - 5.44 1.68 310 2½ 750 3.08 6.13 1.88 - 2.S 05 ,1,'S >111 136 -(0 14 750 4.25 5.75 1.86 3.6 34- 51,5 '06 1413 3 750 4.56 6.81 - 1.88 3.1 no 173 I 4 750 5.81 8.25 2.06 4.8 1141) :'I.' ''UI :'ii) 52 142 750 5.56 7.44 2.06 5.2 41/44- 5 750 7.06 9.75 2.06 7.1 .i 2 700 6.36 9.18 2.06 7.4 5544- .110". 174 :23 1. - 700 6.94 9.42 2.06 7.6 .5125 't;n '.30 6 700 8.00 10.75 2.06 8.7 1,1) 4525 2(13 "4 52 3 700 7.85 10.18 2.06 9.2 - 6/.i 4- 8:'!, 'ilO :':9 5? -' 2 700 8.00 10.75 2.06 7.2 61/2 4: ',lyi ::; .5? 3:' 8 § 600 10.25 '13.50 2.50 14.9 100 ((.30 :'oo or; 105 500 12.6 8 '16.75 2.56 25.0 2.3 ' 12 § 400 14.88 18.50 2.56 28.2 Itlil 2.':)) .3.') 7,) 06 14 300 16.19 19.75 2.94 32.8 'lIt?, 411 ''L'14 75 4 16 300 18.38 21.75 2.94 41.2 400 ''5i5 .1147 107 18 ' 300 20.69 23.88 3.06 54.2 niX> 75 'I 14 20 300 23.00 27.38 3.06 67.2 Soil .5.31!, :,6l nO:, 78 .10 24 250 27.13 31.50 3.13 76.2 4k))) - 'I?:':, 00) 2431) 7)) -- 3.) 14 4- O.D.Dimension. Refer 10 notes on page 7. § Available to J.I.S. dimension Non). Size Max WorK Press. Dimensions - Inches/mm Aprx. WgIEach X V Z Inches/mm PSI'/0Pa Lbs./dg ~ 1,000 2.13 3.63 1.75 - 1.1 'i:' .14 1!' 1 1,000 2.38 3.88 1.75 - 1.3 1900 00 .1.1 1>13 11/4 11/i 1,000 2.63 4.63 1.75 2.0 0' 0001) ii? 113; -I-f '13) '11/2 1,000 3.00 5.00 ' 1.75 2.1 2 ' '0 1 (-I 1,000 3.63 5,63 1.75 - 2.6 6900 1414 143 2½ 1,000 4.25 6.25 1.75 3.1 14.5 0000 1011 lOil -I.-) 'I -I 1,000 4.31 6.31 1.75 3.6 34- oo 110 iOu I-I 1 0 3 1,000 5.00 7.00 1.75 3.5 r30 69011 12: 10; -I-I 11; 31/2 1,000 5.63 8.00 1.75 - 5.6 '30 i301)0 145 20.3 ''-I '5 4 1.000 6,38 8.50 2.00 6.6 614101' 113.3' 2114 51 1,000 5.88 8.06 2.06 - 7.0 4- 01400 119 '0:, "14 5 '1,000 7.63 10.25 2.00 - 10.6 T2 1114014 194 1400 il -IS 1,000 7.34 9.20 2.06 - 0.0 5/44- 0>10)', 11143 .334 :0' II, 5/24- 1,000 7.60 9.44 2.06 11.0 ilSoil 131:1 "Ii) :14' 3,11 6 1,000 9.00 11.50 2.00 - 11.8 50 ii?>))) 12) 9' 1,000 8.50 10.38 2.66 - 13.2 b/i 1 01400 210 ,1144 :':' 00 1 6/z4- 1,000 9.19 11.50 2.06 - 13.2 14000 23.3 "92 '2 011 8 § 800 11.38 14.50 2.38 20.1 SSUO 232)1 .3145 00 91 10§ 800 13.50 16.75 2.50 - 28.3 ' .15 04 (141 125 800 15.50 19.00 2.50 - 34.2 0140 S310() 30L 304 GI 15:. 14 300 16.63 20.00 2.88 - 35.6 15 300 17.88 21.25 2.88 - 48.8 16 300 19.00 22.38 2.88 - 51.1 'ItO .,'0'u':' 410 ',hi 0) 18 300 21.25 24.38 3.13 64.4 -50 2000 340 14 1)1 ,11 20 300 23.50 27.50 3.13 91.2 lOu) 70146'., :149' 1499 U) 411 22 - 300 25.63 30.00 3.13 - 92.0 41 24 250 ' 27.63 31.38 3.13 94.0 1401) 1214 :0:.' 0)' 0) - XI 6 4-0.0. Oimens,on, Refer to notes on pace 7 § Available to J.I.S. dimension. U TLC ,1 0 INCORPORATED CORONA. CA' (909) 737-5599 53 FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range 3/8 thru 7/8 inch rod in 1 inch increments. Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, rod length, and finish. MAX. REC. LOAD LBS, ROD FOR SERVICE TEMPS. SIZE 650°F 750F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 FIG. 100 ALL THREAD ROD FULL LENGTHS Size Range - 1/4 thru 1-1/2 inch rod in 10'.0" lengths. Material - Carbon Steel Maximum Temperature- 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, and finish. MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 65 OF 750F PER 100 FT. 1/4 240 215 12 1/2 1130 1010 53 L8iQP I 3/4 2710 2420 123 1 4960 4420 222 1-1/2 11630 10370 510 TO PLC 0 Ir,conronATo CORONA, CA • (909) 137.5599 15 FIG. 2 ADJUSTABLE RING HANGER FIG 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range - 1/2 thru 6 inch pipe. Material - Carbon Steel, Mil. Galvanized to G-90 specification. Function - For general piping purposes. Knurled .wivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals - Underwriters Laboratories listed and [:actory Mutual Engineering approved. Conforms to Federal Specification WW-N-171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized and Stainless Steel. Order B - Figure number and pipe size. PIPE ROD STOCK MAX, REC. APPROX. WEIGHT PER 100 FIG. 2 SIZE SIZE A B C SIZE LOAD LBS. FIG. 2 NFPA 1/2 3/8 3-1/8 2-5/8 1-3/8 lSgaxl 400 17 17 8/k 8/8.,. , 2 Jj2 1_1J8 1.5gax.) 40Q J.7.. , . 1 3/8 3-3/8 2-5/8 1-1/8 16gax1 400 - -, 18 18 1 114 $1 3 .3/4 7/ U./8 , 16a, 1-1/2 3/8 3-7/8 2-7/8 1 169ax1 400 21 21 2 8/8 1J4 .3 1 16a1 400 2-1/2 1/2* 5-3/4 4-1/4 1-5/8 14ga x 1-3/16 600 41 40 1/4 1413/16 bOO 45 43 3-1/2 1/2* 7.3/8 5.1/4 2-1/8 Aga x 1-3/16 600 52 50 4 5/k 7/S 1 5(8 14ac 1 1/4 1000,. , §9 ,, 5 5/8 9 6-1/8 2-1/4 l2gaxl-1/4 1250 97 95 1250 139 *3/8" nut is used when NFPA rod sizing is requested. "1/2,, nut is used when NFPA rod sizing is requested. IN CO R P0 RATED ].20 CORONA. CA (909) 7 37-5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range. Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 IPS. Material - Carbon Steel Function . For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig, 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA 13*, forming a complete sway brace assembly, Features - Can be used to brace Schedules 10 and 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/It) has been achieved. Application Note - Fast Clamp need not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet 1113, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'-2". 1-1/4" Schedule 40 bracing pipe maximum 9'-2". Approvals - Underwriters' Laboratories listed. Note - Must be used with Tolco U.L. Listed 900 Series attachment. Finish - Plain, Electro-Galvanized, HDG, and Stainless Steel. Order B - Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. [4IiI1111 D A? MOLE SIZE A B C SIZE E F PER 100 2 1-1/2 3 9/16 2-5/16 2 88 INCORPORATED 118 CORONA. CA • (90) 737.5599 FIG. 910 SWIVEL SWAY BRACE FITTING Size Range - 1 & 1.1/4 inch bracing pipe., Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; The Fig. 910 is used in conjunction with the Fig. 1000 "Fast Clamp" (or with a Fig. 4A Pipe Clamp), and joined together with a brace pipe per NFPA #13*. Features - Universal swivel design allows Fig. 910 to be attached at any surface angle. All steel construction eliminates deficiencies associated with casting type attachments. Application Note - *Length of bracing pipe per National Fire Protection Association Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7-2". 1-1/4" Schedule 40 bracing pipe maximum 9'-2". Approvals - Underwriters' Laboratories listed. Note -The Fig. 910 Swivel Attachment and the Fig. 1000 "Fast Clamp" (or Fig. 4A Pipe Clamp), make up a sway brace system of U. L. Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish - Plain, Elec•t.r-atvanized, and Stainless Steel. Order By - Figure number, pipe size, and finish. Note - Specific weight load conditions may require more than one fastener to the building structure. cu,, hrir ttchmnts mw hp nrdrcl with BRCCO Brecco Corporation > GAUGES GAUGES FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURBON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2" DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). Part No. Description Box / Case - GAAWSS350 AIR / WATER 0 300 psi 80 Wt STAINLESS STEEL CASE GAASS250 AIR W/ RETARD 250 PSI 3-1/2' DIA, WI STAINLESS STEEL 60 CASE GAWP200 2" RESIDENTIAL GAUGE 300 PSI (NOT U. L. OR F.M. APPROVED) 100 GAAWP350 AIR I WATER W/ PLASTIC CASE 60 V 1-806'543-4194 Paz: 1-877-474-9248 AR' = AS REQUIRED breccocorp@earthiink.net 082000 _____ •Tcil _____ INCORPORATED CORONA. CA • (909) 737-5599 41. FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) L A H-2--,, .—jl : F JI FIG. 51 FIG, 52 FIG. 51 for NFPA Rod and Fastener Sizing APPROX. PIPE ROD HOLE SIZE STOCK WEIGHT SIZE SIZE A B. C H-I H-2 SIZE PER 100 1/2 2 3/8 2 3/4 2 7/16 7/16 3/16x2 35 3J 2 3/4 2 9/26 ,7/16 3/16x2, 34 • 5-6 1/2 2.1/2 3/4. 2-1/2 9/16 9/16 3/8x2-1/2x2.1/2 71 8 '1/p 2 1/2 3/4 2 1/2 11/16 9/16 3/8.x2 1/2x2 1/2 7Q FIG. 52 - 6 Hole Bracket APPROX. ROD HOLE SIZE WEIGHT C H-i 3/8x1/2 2 1-1/16 2 9/16 7/16 9/32 3/16x2 35 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range 1/2 thru 4 inch pipe (3/8 inch rod). Material - Carbon Steel Function - Practical and economical bracket used to support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approvals - Underwriters' Laboratories listed and Factory Mutual Engineering approved for 1/2 - 4" pipe Finish - Plain, Electro-Galvanized, HDG, and Stainless Steel, Order By - Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch fastener. G IF H ROD APPROX, PIPE SIZE HOLE SIZE . STOCK WEIGHT SIZE AB C DE F G H J SIZE PER 100 1/2 - 4 2-5/8 3/8 1 3/8 1-1/16 1-1/8 7/16 9/16 1-1/4 1/4x1 20 tqCO /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 A en Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series TYFRB - 2.8,4,2,56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2'NPT TY1231 - Pendent 2.8K, 1/2'NPT TY2131 - Upright 4.21K, 1/2'NPT TY2231 - Pendent 4.21K, 1/2'NPT TY3131 - Upright 5.61K, 1/2NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.01K, 314"NPT TY4231 - Pendent 8.01K, 3/4"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) - f • r r Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/ps1112 (40,3 LPM/bar1/2) K = 4.2 GPM/psi112 (60,5 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/barl'2) K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Page 1 of 8 APRIL, 2003 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 7/16(11,1 mm) NOMINAL MAKE-IN 1/2" ** NPT ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN 1/2" ** NPT Page 2 of 8 TFPI7I _F_ 2-1/4" (57,2 mm) SSP DEFLECTOR * PENDENT STYLE 10or20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16" 3 71 NOMINAL (11,1 mm) 2-3/16' mm) L_ "WRENCH (55,6 MAKE-IN FLATS 2- 7/8 (73,0 mm) DIA. 1/2" NPT ** RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (TV1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT T_ 2-3/16" (55,6 mm) 1 SSP DEFLECTOR* PENDENT STYLE 100r20 RECESSED SSU* ESCUTCHEON DEFLECTOR 711 C I (11,1mm) I II NOMINAL I .-_-Li_-_ I sill - L tF FLATS - WRENCHj (59mm) 27/8 (73 1/2 NPT** RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT(TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 16m) (38, SSP DEFLECTOR* DEFLECTOR 7/1 NOMINAL 4 4 2-7/8"(73,o mm) DIA. STYLE 10or2C RECESSED ESCUTCHEON 7/16" (11,1 mm) 1/2" ** NOMINAL NPT MAKE-IN STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR !~ E I WRENCH FLATS -7/8" (73,0 mm) DIA. ESSED PENDENT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE-IN (5 1-9/16" (39,7 mm) \ç/. SSP DEFLECTOR * 2 PENDENT REC * 1/2" (12,7 mm) I NOMINAL I : MAKE-IN _I: 2-1/4" (57,2 mm) -: 3/4 NPT' I UPRIGHT CROSS SECTION TFPI7I Page 3 of 8 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seal on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 4 of 8 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL I CHROME I WHITE' LIQUID BRASS PLATED IPOLYESTER 135°F/57°C Orange PENDENT (TY1231) and 12.3.5 155°F/68C Red 175°F179°C Yellow UPRIGHT 200F/93C Green 2.8 1/2 (TY1131) 286F/141°C Blue NPT 135°F/57C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79C Yellow (TY2231)' 200°F193°C Green Figure 5 1, 2:5 135°F157°C Orange RECESSED 155°F/68C He PENDENT 175°F/79°C Yellow (TY2231)* 200°F/93C Green Figure 6 135°F/57°C Orange PENDENT (TY2231) 155°F/68°C Red 175°F/79°C Yellow and UPRIGHT 200°F/93"C Green 4.2 1/2 (TY3131) 1,2 286F/141'C Blue 135°F/57"C Orange NPT RECESSED 155F/68°C Red PENDENT 175°F/79°C Yellow (TY2231)' Figure 7 200°F/93C Green 135°F/57"C Orange RECESSED PENDENT 155°F/68C Red 175F/79C Yellow (TY2231)** Figure 8 200F/93C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Re- cessed Escutcheon, as applicable. Installed with Style 20 (1/2' NPT) or Style 30 3/4' NPT) 1/2 Total Adjustment Re- cessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A leak tight 1/2 inch NPTsprinkler joint should be obtained with a torque of 7 to 14 ft lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, 0r40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL I CHROME WHITE LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) and 1. 2,3,4,5,6 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200F/93°C Green 5.6 (TY3131) 286F/141C Blue 1/2' NPT 135°F/57°C Orange RECESSED PENDENT 1, 2, 4, 5 N/A 155°F/68C Red 175°F/79°C Yellow (TY3231) Figure 9 200°F/93C Green 135F/57C Orange I RECESSED PENDENT 1,2, 3,4,5 I I 1,2,4,5 N/A 155F/68°C Red 175'F/79 'C Yellow (TY3231)** 200F/93C Green Figure 10 135F/57C Orange PENDENT (TY4231) / 1,2,5 155°F/68°C Red 175°F/79°C Yellow and 1, 2, 3,4,5,6 200F/93C Green UPRIGHT 8.0 (TY4131) 286F/141°C Blue 3/4,, NPT 135°F/57°C Green RECESSED PENDENT 1,2, 4,5 N/A 155F/68C Orange 175°F/79°C Red (TY4231) Figure 11 200°F/93°C Yellow 135°F/57C Orange RECESSED PENDENT 1,2,3,4,5 N/A 155F/68C Red 175F/79C Yellow (TY4231)** Figure 12 200°F/93°C Green NOTES: 1, Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB) as Quick Response Sprinklers; however, the LPC does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01 -E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FA CTOR SPRINKLERS sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Page 6 of 8 - 2-7/8 DIA. - 5/8±1/4' (73.0 mm) I 3/4"(19.1 mm) (15.9±6.4 mm) 2-1/4 DIA. 1/4" (6,4 mm) I FACE OF ._57.2 mm1 MOUNTING SPRINKLER PLATE FITTING 1/8 (3,2 m_j MOUNTING SURFACE 1-5/16" (33.3 mm)I CLOSURE SERIES TY-FRB 13/16" (20.6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4' (73.0 mm) 3/4" (19.1 mm) (15.9±6.4 mm) - 2-1/4" DIA. 1/4" (6.4 mm) I FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8" (3.2 mm) ¼\mm I SURFACE . MOUNTING/ CLOSURE SERIES 1-1/4(31,8mm) TY.FRB 3/4'(19.1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 42 K-FACTOR, 1/2 INCH NPT TFPI7I - 2.7/8" DIA. 1/2±1/8" (73,0 mm) 1 1/2" (12,7 mm) r (12,7±3.2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I I FACE OF [57.2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" - / (3.2 mm) MOUNTING / /1 1 SURFACE I16"(33,3 mmli //I CLOSURE SERIES TY-FRB 1-1/16" (27.0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73,0 mm) I 1/2±1/8" I 1/2" (12,7 mm) r (12.7±3.2 mm) - 2-1/4" DIA. 1/4" (6.4 mm) I FACE OF (572mm) MOUNTING SPRINKLER P FITTING I 1/8" I LATE +MOUNTING SURFACE SERIES 1-1/4" (31.8 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I * 2-7/8' DIA. 5/8±1/4" (73.0 mm) 3/4" (19.1 mm) (15.9±6.4 mm) 2-1/4" DIA. 1/4(6.4mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 57.2 1/8" (3.2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 3/4" (19.1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73.0 mm) - I 3/4" (19.1 mm) I (15.9±6.4 mm) 2-1/4" DIA. 1/4" (6.4 mm) (57,2 mm) MOUNTING I FACE OF PLATE SPRINKLER FITTING 1/8" -I _____ L ___ _________________ (3,2 mm) / I4 ____J mm) MOUNTING SURFACE CLOSURE SERIES i-5!16')33. TYFRB 13/16" (20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 - 2-7/8" DIA. - ( I 1/2±1/8" 73.0 mm) I 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4' (6.4 mm) I FACE OF I MOUNTING I SPRINKLEqR I PLATE 572 FITTING 1/8 (3.2 mm) MOUNTIN SURFACE SERIES 1-1/4" (31.8 mm) CLOSURE TYFRB 1" (25.4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) H 1/2" (12.7 mm) E (12.7±3,2 mm) 2-1/4' DIA. I 1/4" (6.4 mm I FACE OF MOUNTING SPRINKLER PLATE I FITTING 1/8" I (3.2 mm) ,,, j MOUNTING SURFACE/ CLOSURE SERIES 1-5/16" (33,3 mm) TY.FRB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI7I P/N 57- XXX MODEL/SIN 330 2.8K UPRIGHT (1/2'NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2NPT) 1Y2131 341 4.2K PENDENT (1/2NPT) 1Y2231 370 5.6K UPRIGHT (1/2NPT) 1Y3131 371 5.6K PENDENT (1/2'NPT) 1Y3231 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (3/4NPT) TY4231 I I I SPRINKLER L 135 1 NATURAL BRASS 4 WHITE POLYESTER 9 CHROME PLATED 7 LEAD COATED L 155 175 200 1 286 TEMPERATUF RATING 155'F/68°C 175°F/79C 200F/93"C 1 286F/141'C TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE. SALES PRICE. THE FOREGOING WARRANTY IS OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2 (15 mm) Style 10 Chrome Plated .........PIN 56.701.9-010 1/2 (15 mm) Style 10 White Color Coated ................P/N 56-701-4-010 1/2 (15 mm) Style 10 Brass Plated ...........P/N 56-701.2-010 1/2 (15 mm) Style 20 Chrome Plated .........PIN 56-705-9-010 1/2" (15 mm) Style 20 White Color Coated ................P/N 56-705-4-010 1/2" (15 mm) Style 20 Brass Plated ...........P/N 56-705-2-010 3/4 (20 mm) Style 30 Chrome Plated .........P/N 56-705-9-011 3/4 (20 mm) Style 30 White Color Coated ................P/N 56-705-4-011 3/4 (20 mm) Style 30 Brass Plated ...........P/N 56-705-2-011 3/4 (20 mm) Style 40 Chrome Plated .........P/N 56-700-9-010 3/4 (20 mm) Style 40 White Color Coaled ................P/N 56-700-4-010 3/4 (20 mm) Style 40 Brass Plated ...........P/N 56-700-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 SPRINKLER WRENCHING AREA (BOTH SIDES) 1/2 (12,7 mm) MAKE—IN f. r nm) 2-7/8 (73,0 mm) 3/4 NPT goo Gem TYCO FIRE PRODUCTS, 7071 S. 13th Street, Suite 103 Oak Creek, WI 53154— www.gemsprinkter.com Customer Service/Sales; Tel: (877) 436-8926 I Fax: (877) 866-9250 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 EXTENDED COVERAGE LIGHT HAZARD SPRINKLERS PENDENT & RECESSED PENDENT, QUICK & STANDARD RESPONSE MODEL F890 DESIGNER, 3 mm BULB TYPE, K=8.0 - Frame 3 - Gaslceted 4 - Bulb 6 - Deflector* 2 - Button Spring 5 - Compression Plate Screw * Temperature rating is indicated on deflector. Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE A 8.0 K-FACTOR MODEL F890 (SIN G1890) QUICK AND STANDARD RESPONSE EXTENDED COVERAGE LIGHT HAZARD PENDENT AND RECESSED PENDENT SPRINKLERS GENERAL DESCRIPTION The 8.0 K-Factor (17/32 inch orifice), Model F890 Designer Quick and Standard Response Extended Cover- age Light Hazard (ECLH) Pendent and Recessed Pendent Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are in- tended for use In automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for the protection of light hazards up to a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maxi- mum coverage area of 225 ft2 (20,9 M2) for standard coverage sprinklers. The recessed version of the F890 ECLH Sprinkler is obtained by combin- ing the pendent sprinkler with the Model F705 Recessed Escutcheon (Ref. Figures A and B). The F705 Re- cessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of adjustment from the flush pendent position. The F705 is a separable two-piece design which allows installation of the sprin- klers and pressure testing of the fire protection system, prior to ceiling con- struction and/or application of a finish coat to the ceiling. They also permit refinishing of a ceiling surface without having to first shut down the fire pro- tection system and remove sprinklers. The adjustment provided by the F705 substantially reduces the accuracy to which the fixed pipe drops to the sprin- klers must be cut. Also, the Closure has a 1/2 inch (12,7 mm) wide flange which provides ample clearance for covering the mounting hole. Laboratory listings and approvals for the 8.0 K-Factor, Model F890 De- signer Quick and Standard Response Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pen- dent Sprinklers are given in Table A. The laboratory listings and approvals only apply to the service conditions indicated in the Technical Data and Design Criteria sections. WARNING The Model F8.90 Desgner Quick and Standard Response Extended Cover- age Light Hazard (ECLH) Pendent and Recessed Pend.ent Sprinklers de- scribed herein must be in-stalled and maintained in compliance with this docwnent, as well as with the appli- cable standard-s of the Natiowi Fire Protection. Association., in. additioit, to the standards of any other authorities Printed in U.S.A. 3-01 T0594 SPRINKLER FINISH TYPE TEMPERATURE RATING BULB COLOR CODE NATURAL BRASS I CHROME PLATED I POLYESTER COATED (All Colors) PENDENT (SIN G1890) 135°F/57°C Orange 1,2,3 Yellow 155°F/68"C Red 175°F179°C 200°F/93°C Green 1,2 - RECESSED* (SIN G1890) 1350F/57°C Orange 1, 2, 3 Yellow 155F168C Red 175°F/79°C 200°F/93°C Green 1,2 NOTES: Listed by Underwriters Laboratories, Inc. Listed by Underwriters Laboratories for use in Canada (i.e. C-UL Listed). Approved by Factory Mutual Research Corporation. Installed with 3/4 Inch Model F705 Recessed Escutcheon. TABLE A LABORATORY LISTINGS AND APPROVALS (REFER TO TABLE B-i OR B-2 FOR RESPONSE CHARACTERISTICS) .0 r having jurisdiction. Failure to do so may impair the integrity of these de- vices. The owner is responsible for main- taming their fire Protection .syseIn and devices iu proper operating con- dition. The installing contractor or manufacturer should be contacted relative to any questions. Installation of Model F8,9() Peud.ent Sprinklers in recessed escutcheons other than the F705 will void all sprinkler warranties, as well as pos- sib&y void the sprinkler's Approvals and/or Listings. The 8.0 K-Factor, Model F890 De- signer Quick and Standard Response Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pen- dent Sprinklers are rated for use at a maximum service pressure of 175 psi (12,1 bar) and they are available in the temperature ratings and finishes Indi- cated in Table A. Recessed versions of the F890 ECLH Sprinklers are obtained by utilizing the Model F890 Pendent Sprinkler in com- bination with the Model F705 Re- cessed Escutcheon. The Model F705 Escutcheons are available either with a chrome plated finish or a coated fin- ish in any color. The flow "Q" in GPM (LPM) is deter- mined by the formula: where the nominal sprinkler discharge coefficient "K" equals 8.0 (115.2) and "p" equals pressure in psi (bar). The F890 utilizes a 3 mm Bulb with a die-cast dezincification resistant bronze alloy Frame. The two pieces of the Button Assembly are constructed from brass and copper. The Gasketed Spring Plate consists of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a Teflonf gasket. The Compression Screw is a bronze, and the Deflector is brass. The F705 Recessed Escutcheon pro- vided for use with the F890 ECLH Sprinklers (Ref. Figure B) has a Clo- sure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it, maintain a tight friction fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and compensate for non-perpendicularity between the F890 ECLH Sprinkler and the ceiling. The 8.0 K-Factor, Model F890 De- signer Quick and Standard Response Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pen- dent Sprinklers are only to be Installed in accordance with Table B-i or B-2, as applicable. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The diame- ter of the air bubble is approximately 1/16 inch (1,6 nun) for the 135°F/57'C to 200°F/9.3°C tempera- ture ratings. The Model F890 ECLH Sprinklers must be installed in accordance with the following instructions: 1. Prior to Installing each sprinkler, ver- ify that the face of the sprinkler fitting is within the proper range of distance which can be accommodated by the particular type of escutcheon. When installing the F890 Sprinkler with the F705 Recessed Escutch- eon, for best overall appearance, use Dimension "A" indicated under the "Fully Recessed Dimensions" heading of Figure B. Otherwise, use Dimension "A" under the "High Ad- justment Dimensions" heading. In either case, the remaining adjust- ment can then be used to compen- sate for the possible manufacturing variations in the take-out of the fit- tings, as well as in the make-in of the sprinklers (as permitted by ANSI Bi.20.1). With pipe thread sealant applied to the pipe threads and after installing the F705 Mounting Plate (or other escutcheon, as applicable) over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. —2— f DuPont Registered Trademark WRENCH ECESS FIGURE D W-TYPE10 RECESSED SPRINKLER WRENCH FULLY RECESSED DIMENSIONSt Up to 1/4 Inch adjustment from minimum 1/4 Inch to maximum 1/2 Inch recessed position. Dim. Inches MM A- 1/2tt 12,7 B-Mm. 1-1/8 28,6 B-Nom. 1-1/4 31,8 B-Max. 1-3/8 34,9 C-Mm. 1/4 6,4 C-Max. 1/2 12,7 HIGH ADJUSTMENT DIMENSIONS Up to 1/2 Inch adjustment from the flush ceiling position to 1/2 Inch recessed position. Dim. Inches MM A- 3/8±1/8ff 95±3,2 B-Mm. 1-1/8 28,6 B-Nom. 1-3/8 34,9 B-Max. 1-5/8 41,3 C-Mm. FLUSH - C-Max. 1/2 12,7 t For best overall appearance. FA F 1 A F MOUNTING SURFACE Model F890 ECLH Pendent Sprinkler Model F705 Recessed Escutcheon Mounting Plate Closure ft Remaining 1/4 inch (6,4 mm) of adjustment can be used to compensate for variations in sprinkler make-in and fitting take-out. FIGURE B 8.0 K-FACTOR MODEL F890 ECLH RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F705 RECESSED ESCUTCHEON 3. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 9 or W-Type 10 Sprinkler Wrench (Ref. Figure CorD). The W-Type 9 wrench recess is to be applied to the sprin- kler wrenching area (Ref. Figure A), and the W-Type 10 wrench recess is to be applied to the wrenching flanges adjacent to the sprinkler wrenching area. The W-Type 10 Sprinkler Wrench is principally for use with fixed ceiling installations where the sprinkler wrenching area is not accessible. NOTES A teak tight 314 inch NPT sprin.- k/er joint should be obtained with torque of 10 to 20 ft.lbs. (134to 268 Nn). Higher levels of torque may distort the sprinkler inlet with consequent leakage or iin- pairment of the sprinkler. Do not attempt to inoke-up for in- sufficient adjustment in the es- catchAeoit plate by ia4er- or over- FIGURE C W-TYPE 9 SPRINKLER WRENCH tightening the sprinkler. Readjust the position of the spri nh/er fitting to suit. 4. In recessed installations, after the ceiling has been installed or the fin- ish coat has been applied, slide on the F705 Closure over the F890 Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. RESPONSE COVERAGE AREA W x L FT. x Ft (m x m) MINIM FLOWt' GPM (LPM) MINIMLIM PRES. PSI (BAR) PENDENT SPRINKLER TEMP. RATING OF RECESSED SPRINKLER TEMP. RATING OF QUICK 16x 16(4,9x4,9) 26(98) 10.6(0,73) 135,155,175 135, 155,175 18x18(5,5x5,5) 32(121) 16.0 (1,10), 135,155,175 135, 155,175 20x20(6,1 x6,1) 40(151) 25.0(1,72) 135,175 135,175 STANDARD 16 x 16 (4,9 x 4,9) 26 (98) 10.6 (0,73) 200 200 18 x 18 (5,5 x 5,5) 32(121) 16.0(1,10) 200 200 20x20(6,1 x6,1) 1 40(151) 125.0(1,72) 155,200 1 155,200 NOTES: The F890 (SIN G1890) Sprinklers may be used in OR-EC and EC, as applicable, Light Hazard Occupancy automatic sprinkler applications per NFPA 13. Requirement is based on minimum flow In GPM from each sprinkler. The indicated residual pressures are based on the nominal K-factor. The F890 (SIN G1890) ECLH Sprinklers are only permitted to be used with unobstructed, smooth ceiling construction as defined by NFPA 13. Follow the requirements of NFPA 13 for spacing of the F890 (SIN G1890) ECLH Sprinklers with respect to ceiling mounted obstructions, (a) The minimum allowable spacing between the F890 (SIN G1890 )ECLH Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). (I) The maximum permitted ceiling slope for F890 (SIN G1890) ECLH Sprinklers is a 2 Inch (50,8 mm) rise over a 12 inch (304,8 mm) horizontal run. TABLE B-i UL AND C-UL LISTING CRITERIA FOR INSTALLATION OF 8.0 K-FACTOR MODEL F890 EXTENDED COVERAGE LIGHT HAZARD PENDENT AND RECESSED PENDENT SPRINKLERS RESPONSE COVERAGE AREA W x L Ft x Ft (m x m) MINIMUM FLOW' GPM (LPM) MINIMUM PRES.'' PSI (BAR) PENDENT SPRINKLER TEMP. RATING OF RECESSED SPRINKLER TEMP. RATING OF QUICK 16 x 16(4,9 x 4,9) 26(98) 10.6(0,73) 135, 155, 175 135 18 x 18 (5,5 x 5,5) 32(121) 116.0(1,10) 135,155,175 135 20x20(6,1 x6,1) 40(151) 25.0(1,72) 135,155,175 135 STANDARD 16 x 16 (4,9 x 4,9) 26(98) 10.6(0,73) - 155,175 18 x 18 (5,5 x 5,5) 32(121) 16.0(1,10) - 155,175 20 x 20 (6,1 x 6,1) 40(151) 25.0 (1,72), - 155,175 NOTES: The F890 (SIN G1890) ECLH Sprinklers maybe used in QR-EC and EC, as applicable, Light Hazard Occupancy automatic sprinkler system applications per FM Installation standards. Requirement is based on maintaining both minimum flow and minimum pressure. The F890 (SIN G1890) ECLH Sprinklers are only permitted to be used with smooth level ceilings per FM installation standards. The minimum allowable spacing between the F890 (SIN G1890) ECLH Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). The maximum permitted ceiling slope for F890 (SIN G1890) ECLH Sprinklers is 1 inch (25,4 mm) rise over a 12 inch (304,8 mm) horizontal run. (I) The deflector-to-ceiling distance for the F890 (SIN G1890) ECLH Sprinklers is 1-5/8 to 4 inches (41,3 to 101,6 mm), unless the Model F705 Recessed Escutcheon is utilized. (g) The maximum ceiling height for the F890 (SIN G1890) ECLH Sprinklers is 10 feet (3,1 m). TABLE B-2 FM APPROVAL CRITERIA FOR INSTALLATION OF 8.0 K-FACTOR MODEL F890 EXTENDED COVERAGE LIGHT HAZARD PENDENT AND RECESSED PENDENT SPRINKLERS The Model F890 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTE Before closing fire protect ion system control valve for ,naintenv,nce work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and alipersonnel who may be affected by this action must be notified. Absence of an escLacheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire sit wit ion. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service. Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper Installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDI- RECT, SPECIAL OR CONSEQUEN- TIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. —5— I SPRINKLER FINISH 135 155 175 TEMPERATURE RATING 1 NATURAL BRASS 135°F/57°C 4 WHITE POLYESTER 155°F/68°C 9 CHROME PLATED 1750F179°C 200 I 200°F/93°C TABLE C PRODUCT SYMBOL NUMBER SELECTION -$ •:Ii• - PSN51-890-X-XXX A Product Symbol Number (PSN) is not specified when ordering polyester coated F890 ECLH Sprinklers with other than a white color or, when or- dering color coated F705 Recessed Escutcheons with other than a white color. it is suggested that a color chip be provided when ordering special color finishes. Otherwise, responsibil- ity for duplication cannot be accepted. Contact your local distributor for avail- ability. "Standard Order" Sprinkler Assemblies with NPT Thread Connections: Specify: 8.0 K-factor, (specify tem- perature rating), Model F890 ECLH Pendent Sprinkler with (specify finish), PSN (specify - from Table C, where applicable). "Special Order" Sprinkler Assemblies with ISO 7/1 Thread Connections: Specify: 8.0 K-factor, (specify tem- perature rating), Model F890 ECLH Pendent Sprinkler with (specify finish) and with thread connection per ISO 7/1. Recessed Escutcheon: Specify: 3/4' Model F705 Recessed Escutcheon with (specify finish), PSN (specify). F705 Recessed Escutcheon Chrome Plated ..........PSN 56-705-9-011 White Color Coated ..............PSN 56-705-4-011 Sprinkler Wrench: Specify: W-Type 9 Sprinkler Wrench, PSN 56-000-1-849 Specify: W-Type 10 Recessed Sprin- kler Wrench, PSN 56-000-1-948. The nominal weights are as follows: 8.0 K-Factor, Model F890 ECLH Pendent Sprinkler 2.3 OZ. (65 9) 3/4' Model F705 Recessed Escutcheon 1.2 ozs. (34 g) W-Type 9 Spnnkler.Wrench .......... 17.0 ozs. (4.809) W-Type 10 Sprinkler Wrench..........10.5 OZS. (300 9) tYCO/Fiow Conrrol/ Tyco Fire Products cT3o124- "I Page 1 of 11441fr System No. W-L-2201 75 U E 00 0 0 December 03, 1999 F Ratings —1 and 2 Hr (See Item I) I Ratings 1, 1-3/4 and 2 Hr (See Item 1) L A L 11 T i 1...i€1 Section A-A 1. Wall Assembly The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: Studs Wall framing shall consist of wood studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Gypsum Board* Mm 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers and orientation shall be as specified in the individual U300 Wall and Partition Design. Max diam of opening is 3-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. The hourly T Rating of the firestop system is 1 when installed in 1 hr rated walls. The hourly T Rating of the firestop system when installed in 2 hr rated walls is dependent upon which side of the wall is exposed to the fire. If the side opposite the pipe is exposed, the T Rating is 1-3/4 hr. If the side containing the pipe is exposed, the T Rating is 2 hr. 2. Through Penetrants One nonmetallic pipe installed within stud cavity and connected to a 900 elbow. Additional nonmetallic pipe connected to elbow and penetrates one side of wall concentrically within the opening. The annular space between nonmetallic pipe and periphery of opening shall be nom 5/8 in. Pipe to be rigidly supported within wall and on penetrated side of wall assembly. The following types and sizes of nonmetallic pipes may be used: http://www.metacaulk.com/ulsystems/W-1-2201.htrnl 12/5/2003 Page 2 of 2 Polyvinyl Chloride (PVC) Pipe Nom 2 in. diam (or smaller) Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping system. Acrylonitrile Butadiene Styrene (ABS) Pipe Nom 2 in. diam (or smaller) Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. Chlorinated Polyvinyl Chloride (CFVC) Pipe Nom 2 in. diam (or smaller) SDR1.7 CPVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. 3. Firestop System The firestop system shall consist of the following: Packing Material In 2 hr rated wall assemblies, foam backer rod firmly packed into opening as a permanent form. Packing material to be recessed from surface of wall as required to accommodate the required thickness of fill material. Fill, Void or Cavity Material *--Caulk Mm 1/2 in. thickness of fill material applied within the annulus, flush with surface of wall. RECTORSEAL - Metacaulk 1000 *Bearing the UL Classification Marking http://www.metacaulk.com/ulsystems/w4-2201.html 12/5/2003 §'i (I) Page 1 of 2 System No. W-L-2 104 May 08, 1998 F Rating —2 Hr T Rating - 1-1/2 Hr ! A: -A 3B - - 3A ... - SECTION A-A 1. Wall Assembly The fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: Studs Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be mm 2-1/2 in. wide and spaced max 24 in. OC. Gypsum Board* Two layers of nom 5/8 in. thick gypsum wallboard, as specified in the individual Wall andPartition Design. Max diam of opening is 3- 5/8 in. 2. Through Penetrant One nonmetallic pipe or tube to be centered within the firestop system with a nom 5/8 in. annular space. Pipe or tube to be rigidly supported on both sides of wall assembly. The following types and sizes of pipes may be used: A. Polyvinyl Chloride (PVC) Pipe Nom 2 in. diam (or smaller) solid core Schedule 40 PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. Chlorinated Polyvinyl Chloride (CPVC) Pipe Nom 2 in. diam (or smaller) SDR 17 cvc pipe for use in closed (process or supply) piping systems. Crosslinked Polyethylene (PEX) Tubing Nom 1 in. diain (or smaller) SDR 9 PEX tube for use in closed (process or supply) piping systems. http://www.metacaulk.com/ulsystems/w4-2104.htrnl 12/5/2003 Page 2 of 2 3. Firestop System The firestop system shall consist of the following: Packing Material Foam backer rod firmly packed into opening as a permanent form. Packing material to be recessed from both surfaces of wall as required to accommodate the required thickness of fill material. Fill, Void or Cavity Material* - Caulk Mm 3/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. RECTORSEAL - Metacaulk 1000 *Beg the UL Classification Marking http://www.metacaulk.com/ulsystems/W-1-2104.html 12/5/2003 LIFEGUARD FIRE PROTECTION, I§k 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92O 0"0(760) 806-9997 9 FAX (760) 806-4813 fr Hydraulic Design Information Sheet ASoo224 Name: La Costa Greens Date: 03/24/04 Location: 1953 Dove Lane Building: New System No. Attic Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP2 Construction: 0 Combustible LI Non-Combustible Ceiling Height 11 '-0" Ft. SYSTEM DESIGN NFPA 13: Z Light Hazard Ordinary Hazard Group LI 1 LI 2 [] 3 0 Extra Hazard fl NFPA 231 D NFPA 231C: Figure: Curve: O Other (Specify) 0 Specific Ruling Made By Date Area of Sprinkler Operation 1050 sq ft System Tvne Density .10 Z Wet [I] Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 155 sq ft Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model TY-FRB Hose Allowance GPM: Outside 100 Size 1/2" K-Factor: 5.6 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 291.19 PSI Required 53.34 At City Connection "C" Factor Used: Overhead 120 Underground 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation. 190' 1 Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack LI Single Row O Conventional Pallet LI Double Row O Slave Pallet 0 Multiple Row []Open Flue Spacing In Inches Longitudinal ____ Transverse - Horizontal Barriers Provided LI Automatic Storage LI Encapsulated LI Solid Shelving LI Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg #1 attic .10/1500 Sigma Dyne mba Corporation 7700 Supply I Demand Graph iv 05 -i I Margin Pressure 11.44 PSI j Flow 1563.44 GPM ____ ____ _____ ______ ______ ______ _______ _______ 00 90 70 654 40 ao 101 200 400 600 600 1000 Nils 1200 1400 1600 1600 20 Water Flow (GPM) System Demand.. Sprinkler Demand 52.67 PSI t 291.19 GPM Additional Flows 100.00 GPM Hose at Source 0.00 GPM Total Demand 52.75 PSI 0 391.19 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI S 1480.00 GPM 1 StJMITTAL SERIAL NO:2932HY4 La Costa Greens Building #1 attic .10/1050 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM 03-08-2002 PAGE 1 CITY PRESSURE AVAILABLE AT 391.2 GPM SUMMARY OF SPRINKLER OUTFLOWS 64.19 PSI ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 103 28.40 15.50 5.60 25.71 106 24.51. 15.50 5.60 19.16 107 24.37 15.50 5.60 18.94 108 24.60 15.50 5.60 19.29 109 23.63 15.50 5.60 17.81 112 26.31 15.50 5.60 22.08 113 23.73 15.50 5.60 17.96 118 16.05 15.50 5.60 8.21 119 15.76 15.50 5.60 7.92 120 15.69 15.50 5.60 7.85 121 18.64 15.50 5.60 11.08 122 17.17 15.50 5.60 9.40 123 16.83 15.50 5.60 9.03 124 15.50 15.50 5.60 7.66 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 8 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 110 TO 111 291.19 GPM 100.00 GPM 391.19 GPM 52.75 PSI 0.00 PSI 25.19 FPS SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #1 attic .10/1050 Location Flow Pipe in Size From To GPM IN 117 124 1.080 Q 15.50 AO ------------------ 116 123 Q 16.83 ------------------ 115 122 Q 17.17 ------------------ 114 121 Q 18.64 1.080 AO 1.080 AO 1.080 AO ------------------ 119 120 Q 15.69 118 119DQ 15.76 Q 31.45 117 118DQ 16.05 Q 47.50 116 117DQ 15.50 Q 63.00 115 116DQ 16.83 Q 79.83 114 115DQ 17.17 Q 97.00 113 114DQ 18.64 Q 115.64 1.639 BN 1 .639 BN 1.639 BN 1 .639 EN 1 .639 EN 1.639 EN 1 .639 BN I 1 03-08-2002 PAGE 2 Fittings Equiv Friction Pressure & Length Loss Summary Devices Ft PSI/Ft PSI L 7.33 C=120 PT 7.66 (124) F=T,2E F 10.40 PE -0.54 T 17.73 0.0705 PF 1.25 PT 8.37 (117) L 0.83 C=120 PT 9.03 (123) F=T F 5.80 PE -0.11 T 6.63 0.0821 PF 0.54 PT 9.46 (116) L 4.00 C=120 PT 9.40 (122) F=T F 5.80 PE 0.43 T 9.80 0.0851 PF 0.83 PT 10.66 (115) L 0.83 C=120 PT 11.08 (121) F=T F 5.80 PE -0.11 T 6.63 0.0991 PF 0.66 PT 11.63 (114) L 8.33 C=120 PT 7.85 (120) F=0 F 0.00 PE 0.00 T 8.33 0.0094 PF 0.08 L 8.33 C=120 PT 7.93 (119) F=0 F 0.00 PE 0.00 T 8.33 0.0342 PF 0.28 L 2.17 C=120 PT 8.21 (118) F=0 F 0.00 PE 0.00 T 2.17 0.0734 PF 0.16 L 4.50 C=120 PT 8.37 (117) F=E F 4.40 PE 0.00 T 8.90 0.1237 PF 1.10 L 6.25 C=120 PT 9.47 (116) F=0 F 0.00 PE 0.00 T 6.25 0.1917 PF 1.20 L 3.50 C=120 PT 10.67 (115) F=0 F 0.00 PE 0.00 T 3.50 0.2749 PF 0.96 L 7.83 C=120 PT 11.63 (114) F=2E F 8.80 PE 0.00 T 16.63 0.3805 PF 6.33 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #1 attic .10/1050 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 112 113DQ 23.73 1.639 L 7.67 C=120 PT 17.96 (113) Q 139.37 F=0 F 0.00 PE 0.00 BN T 7.67 0.5375 PF 4.12 111 112DQ 26.31 1.639 L 7.67 C=120 PT 22.08 (112) Q 165.68 F=0 F 0.00 PE 0.00 BN T 7.67 0.7402 PF 5.68 110 111 1.639 L 7.67 C=120 PT 27.76 (111) Q 165.68 F=0 F 0.00 PE 0.00 BN T 7.67 0.7402 PF 5.68 33 110 2.104 L 10.33 C=120 PT 33.44 (110) Q 165.68 FT/2E F 21.90 PE 0.00 BN T 32.23 0.2193 PF 7.07 31 33 2.104 L 3.50 C=120 PT 40.51 ( 33) Q 165.68 F=T F 10.90 PE 1.52 NR T 14.40 0.2193 PF 3.16 PT 45.19 ( 31) 105 ------------------ 109 1.080 L 4.50 C=120 PT 17.81 (109) Q 23.63 F=T F 5.80 PE 0.54 AO T 10.30 0.1538 PF 1.58 PT 19.93 (105) 104 ------------------ 108 1.080 L 3.58 C=120 PT 19.29 (108) Q 24.60 F=T,E F 8.10 PE -0.32 AO T 11.68 0.1656 PF 1.93 PT 20.90 (104) 106 107 1.639 L 10.00 C=120 PT 18.94 (107) Q 24.37 F=0 F 0.00 PE 0.00 BN T 10.00 0.0214 PF 0.21 105 106DQ 24.51 1.639 L 5.67 C=120 PT 19.15 (106) Q 48.88 F=E F 4.40 PE 0.00 BN T 10.07 0.0774 PF 0.78 104 105DQ 23.63 1.639 L 6.00 C=120 PT 19.93 (105) Q 72.52 F=0 F 0.00 PE 0.00 BN T 6.00 0.1605 PF 0.6 103 104DQ 24.60 1.639 L 8.67 C=120 PT 20.89 (104) Q 97.11 F=E/E F 8.80 PE 0.00 BN T 17.47 0.2755 PF 4.81 SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #1 attic .10/1050 Location Flow Pipe Fittings in Size & From To GPM IN Devices 102 103DQ 28.40 1.639 L Q 125.51 F=0 F BN T 101 102 1.639 L Q 125.51 F=0 F BN T 32 101 1.639 L Q 125.51 F=T F BN T 03-08-2002 PAGE 4 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 8.33 C=120 PT 25.70 (103) 0.00 PE 0.00 8.33 0.4428 PF 3.69 8.42 C=120 PT 29.39 (102) 0.00 PE 0.00 8.42 0.4428 PF 3.73 11.08 C=120 PT 33.12 (101) 8.70 PE 0.00 19.78 0.4428 PF 8.76 30 32 2.104 L 3.50 C=120 PT 41.88 ( 32) Q 125.51 F=T F 10.90 PE 1.52 NR T 14.40 0.1312 PF 1.89 PT 45.29 ( 30) 3 8 ------------------ 7.758 L 158.00 C=150 PT 52.56 ( 8) Q 302.59 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0008 PF 0.19 1 3 7.758 L 1.00 C=150 PT 52.75 ( 3) Q 302.59 F=0 F 0.00 PE 0.00 LU T 1.00 0.0008 PF 0.00 PT 52.75 ( 1) 7 8 ------------------ 7.758 L 220.00 C=150 PT 52.56 ( 8) Q 88.60 F=GV F 6.04 PE 0.00 LU T 226.04 0.0001 PF 0.02 6 7 7.758 L 623.00 C=150 PT 52.58 ( 7) Q 88.60 F=EE,GV,'EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0001 PF 0.07 5 6 7.758 L 415.00 C=150 PT 52.65 ( 6) Q 88.60 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0001 PF 0.05 4 5 7.758 L 174.00 C=150 PT 52.70 ( 5) Q 88.60 F0 F 0.00 PE 0.00 LU T 174.00 0.0001 PF 0.02 2 4 7.758 L 596.00 C=150 PT 52.72 ( 4) Q 88.60 F=T,GV,4EE/GV,2EE F 146.52 P8 0.00 LU T 742.52 0.0001 PF 0.07 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 5 La Costa Greens Building #1 attic .10/1050 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 1 2 7.758 L 1.00 C=150 PT 52.79 ( 2) Q 88.60 F=0 F 0.00 PE 0.00 LU T 1.00 0.0001 PF 0.00 PT 52.79 C 1) ------------------ 30 31 4.310 L 17.00 C=120 PT 45.18 ( 31) Q 165.68 F=0 F 0.00 PE 0.00 FM1 T 17.00 0.0067 PF 0.11 15 30DQ 125.51 4.310 L 81.00 C=120 PT 45.29 ( 30) Q 291.19 F=3E/4E F 66.36 PE 0.00 FM1 T 147.36 0.0189 PF 2.79 11 15 4.310 L 11.25 C=120 PT 48.08 ( 15) Q 291.19 F=E F 9.48 PE 4.87 FR T 20.73 0.0189 PF 0.39 10 11 4.280 L 7.00 Cr140 PT 53.34 ( 11) Q 291.19 F=E F 17.92 PE 0.00 UN T 24.92 0.0147 PF 0.37 8 10 4.266 L 290.00 C=150 PT 53.71 ( 10) Q 291.19 F=T,GV,DDC/5E,2EE F 153.67 PE -21.88 UN T 443.67 0.0132 PF 5.86 4" Watts 909 RPDA 14.88 PT 37.69 C 8) 0 1 7.758 L 1.00 C=150 PT 52.75 C 1) Q 391.19 F=0 F 0.00 PE 0.00 UN T 1.00 0.0012 PF 0.00 PT 52.75 C 0) 0 Automatic Storage Li Solid Shelving Li Encapsulated El Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. - In. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 ( 7 6 0 ) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1953 Dove Lane - Building: New System No. Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. Construction: E Combustible Li Non-Combustible Ceiling Height SYSTEM DESIGN Pendents FP2 11'-O" Ft. NFPA 13: Light Hazard Ordinary Hazard Group El -1-F] 2 [] 3 Li Extra Hazard Li NFPA 231 U NFPA 231 C: Figure: Curve: Z Other (Specify) Area reduced per NFPA 13 Section 7-2.3.2.4 [I Specific Ruling Made By Date Area of Sprinkler Operation 923 sq ft System Type Density .10 E Wet L] Dry Li Deluge Li Pre-Action Area Per Sprinkler 18' x 18' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model F-890 Hose Allowance GPM: Outside 100 Size 17/32" K-Factor: 8.0 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 183.00 PSI Required 46.00 At City Connection "C" Factor Used: Overhead 120 Underground 150 WATPR QTIPPIV Water Flow Test Pinup Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department MULTJ 10 III PIP WI II] MIAMI Commodity Storage Height Storage Method: Solid Piled Class Area % Palletized Location - Aisle Width % Rack Rack D Single Row Li Conventional Pallet Li Double Row El Slave Pallet Li Multiple Row Li Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided I I I I I I La Costa Greens Bldg #1 Pendents .10/923 Sigma Dynamics Corporation 7700 Supply I Demand Graph 2 15 -I Margin J Pressure 22.12 PSI j Flow 2452.70 GPM - - - - - - ____ ____ ____ _____ _____ ______ ______ _______ 00 90-- 85 80 70 - - -'----- _-.. - 50 45 40 35 - - - - - - - 30 as I'd i(-------_________________ Inn Ann Ann Ann inry inn 14fl0 leon 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand 42.28 PSI 1 183.00 GPM Additional Flows 100.00 GPM Hose at Source 0,00 GPM Total Demand 42.34 PSI 0 283.00 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI I 1480.00 GPM Elevation 0.00 PSI 03-08-2002 PAGE 1 SUMITTAL SERIAL NO:2932HY4 La Costa Greens Building #1 .10/923 pendents FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 283.0 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 153 34.59 32.00 8.00 18.69 154 33.48 32.00 8.00 17.51 155 32.00 32.00 8.00 16.00 158 41.32 32.00 8.00 26.68 159 41.61 32.00 8.00 27.06 64.46 PSI TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 8 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 22 TO 150 183.00 GPM 100.00 GPM 283.00 GPM 42.34 PSI 0.00 PSI 15.22 FPS I I SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #1 .10/923 pendents Location Flow Pipe Fittings in Size & From To GPM IN Devices 152 155 1.080 L Q 32.00 F=T,E/E F BN T 151 152 1.639 L Q 32.00 F2E F BN T 157 159 ------------------- 1.080 L Q 41.61 F=T,E F EN T 156 157 1.639 L Q 41.61 F=0 F EN T 156 158 ------------------ 1.080 L Q 41.32 F=T,E F EN T 23 156DQ 41.61 1.639 L Q 82.94 F=T F BN T 21 23 2.104 L Q 82.94 F=T F NR T 151 154 ------------------ 1.080 L Q 33.48 F=T,E F EN T 150 151DQ 32.00 1.639 L Q 65.48 F=E F BN T 150 153 ------------------ 1.080 L Q 34.59 F=T,E F EN T 22 150DQ 65.48 1.639 L Q 100.06 F=T F BN T 03-08-2002 PAGE 2 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 2.00 C=120 PT 16.00 (155) 10.40 PE -0.43 12.40 0.2694 PF 3.34 21.00 C=120 PT 18.91 (152) 8.80 PE -0.22 29.80 0.0353 PF 1.05 PT 19.74 (151) 1.00 C=120 PT 27.06 (159) 8.10 PE -0.43 9.10 0.4380 PF 3.99 10.00 C=120 PT 30.62 (157) 0.00 PE 0.00 10.00 0.0574 PF 0.57 PT 31.19 (156) 3.33 C=120 PT 26.68 (158) 8.10 PE -0.43 11.43 0.4323 PF 4.94 27.50 C=120 PT 31.19 (156) 8.70 PE 0.00 36.20 0.2057 PF 7.45 2.50 Cr120 PT 38.64 ( 23) 10.90 PE 1.08 13.40 0.0610 PF 0.82 PT 40.54 ( 21) 1.00 C=120 PT 17.51 (154) 8.10 PE -0.43 9.10 0.2925 PF 2.67 19.00 C=120 PT 19.75 (151) 4.40 PE 0.00 23.40 0.1329 PF 3.11 PT 22.86 (150) 6.67 C=120 PT 18.69 (153) 8.10 PE -0.43 14.77 0.3111 PF 4.59 44.50 C=120 PT 22.85 (150) 8.70 PE 0.00 53.20 0.2912 PF 15.49 I I SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #1 .10/923 pendents Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 20 22 2.104 L 2.50 C=120 PT 38.34 ( 22) Q 100.06 F=T F 10.90 PE 1.08 NR T 13.40 0.0863 PF 1.16 PT 40.58 ( 20) 3 ------------------ 8 7.758 L 158.00 C=150 PT 42.24 ( 8) Q 218.86 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0004 PF 0.09 1 3 7.758 L 1.00 C=150 PT 42.33 ( 3) Q 218.86 F=0 F 0.00 PE 0.00 LU T 1.00 0.0004 PF 0.00 PT 42.33 ( 1) 7 ------------------ 8 7.758 L 220.00 C=150 PT 42.24 C 8) Q 64.14 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 6 7 7.758 L 623.00 C=150 PT 42.24 ( 7) Q 64.14 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 .PF 0.00 5 6 7.758 L 415.00 C=150 PT 42.24 C 6) Q 64.14 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 4 5 7.758 L 174.00 C=150 PT 42.24 ( 5) Q 64.14 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 2 4 7.758 L 596.00 C=150 PT 42.24 C 4) Q 64.14 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 42.24 ( 2) Q 64.14 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 ------------------ PT 42.24 ( 1) 20 21 4.310 L 26.00 C=120 PT 40.53 C 21) Q 82.94 F=0 F 0.00 PE 0.00 FM1 T 26.00 0.0019 PF 0.05 15 20DQ 100.06 4.310 L 9.00 C=120 PT 40.58 C 20) Q 183.00 F=4E F 37.92 PE 0.00 FM1 .T 46.92 0.0080 PF 0.38 1 I SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 4 La Costa Greens Building #1 .10/923 pendents Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 11 15 4.310 L 11.25 C=120 PT 4096 ( 15) Q 183.00 F=E F 9.48 PE 4.87 FR T 20.73 0.0080 PF 0.17 10 11 4.280 L 7.00 C=140 PT 46.00 ( 11) Q 183.00 F=E F 17.92 PE 0.00 UN T 24.92 0.0062 PF 0.15 8 10 4.266 L 290.00 C=150 PT 46.15 ( 10) Q 183.00 F=T,GV,DDC/5E,2EE F 153.67 PE -21.88 UN T 443.67 0.0056 PF 2.48 4" watts 909 RPDA 15.49 PT 26.75 ( 8) ------------------ 0 1 7.758 L 1.00 C=150 PT 42.34 ( 1) Q 283.00 F=0 F 0.00 PE 0.00 UN T 1.00 0.0007 PF 0.00 PT 42.34 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1945 Dove Lane Building: New System No. Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. Construction: 21 Combustible LI Non-Combustible Ceiling Height SYSTEM DESIGN Carport FP4 8'-O" Ft. NFPA 13: LI Light Hazard Ordinary Hazard Group LI NFPA 231 D NFPA 23 1C: Figure: 0 Other (Specify) Area reduced per NFPA 13 Section 7-2.3.2.4 LI Specific Ruling __ Made By 1 LI 2 LI 3 LI Extra Hazard Curve: Date Area of Sprinkler Operation 900 sq ft System Type Density .15 Z Wet LI Dry [1 Deluge LI Pre-Action Area Per Sprinkler 125 sq ft Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside 250 Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 [W.11 1101 F'.'4 III) 11313L, GPM Required 156.21 PSI Required 65.83 At City Connection "C" Factor Used: Overhead 120 Underground 150 RITA I WANII'J !J M Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department I Ia I '.JAJ%'.J Commodity Storage Height ______ Storage Method: Solid Piled Class Area % Palletized Location - Aisle Width % Rack Rack 0 Single Row LI Conventional Pallet LI Double Row LI Slave Pallet LI Multiple Row LI Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided 0 Automatic Storage • 0 Encapsulated LI Solid Shelving LI Non-Encapsulated Clearance From To of Storage to Ceiling Ft. In. La Costa Greens Bldg #3 carport .151900 Sigma Dynamics Corporation 7700 Sunn1w 1 Demand f4rai3h Iu 120 - - - - - - - ____ _____ ______ ______ _______ _______ _______ ________ _____________________________ 115 - - - - -1 Margin Pressure 9.57 PSI Flow 1382.91 GPM - ____ ____ _____ _____ ______ _______ _______ _______ 105 100 80 75 70 66i 60 60 2. 10 - - - _ I 200 400 600 800 __ 1000 I __ __ 1200 __ ___ 1400 ___ ___ 1600 ___ ___ 1800 ____ N1 -86 201 Water Flow (GPM) System Demand.. Sprinkler Demand 54.31 PSI Additional Flows Hose at Source Total Demand 54.57 PSI 156.21 GPM 250.00 GPM 0.00 GPM 406.21 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI 1480.00 GPM SUMITTAL SERIAL NO:2932HY4 La Costa Greens Building #3 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 406.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 20.59 18.75 5.60 13.52 102 19.96 18.75 5.60 12.70 103 19.65 18.75. 5.60 12.32 104 19.57 18.75 5.60 12.21 105 19.74 18.75 5.60 12.42 106 19.12 18.75 5.60 11.66 107 18.83 18.75 5.60 11.31 108 18.75 18.75 5.60 11.21 03-09-2002 PAGE 1 64.14 PSI TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 7 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 20 TO 101 156.21 GPM 250.00 GPM 406.21 GPM 54.57 PSI 0.00 PSI 14.12 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #3 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 104 108 1.080 L 10.00 C=120 PT 11.21 (108) Q 18.75 F=0 F 0.00 PE 0.00 EN T 10.00 0.1002 PF 1.00 23 104DQ 19.57 1.080 L 5.25 C=120 PT 12.21 (104) Q 38.32 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3760 PF 5.02 ------------------ PT 17.55 ( 23) 103 107 1 .080 L 10.00 C=120 PT 11.31 (107) Q 18.83 F=0 F 0.00 PE 0.00 BN T 10.00 0.1010 PF 1.01 22 103DQ 19.65 1.080 L 5.25 C=120 PT 12.32 (103) Q 38.49 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3790 PF 5.06 ------------------ PT 17.70 •( 22) 102 106 1.080 L 10.00 C=120 PT 11.66 (106) Q 19.12 F=0 F 0.00 PE 0.00 EN T 10.00 0.1039 PF 1.04 21 102DQ 19.96 1.080 L 5.25 C=120 PT 12.70 (102) Q 39.08 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3900 PF 5.21 PT 18.23 ( 21) 101 105 1.080 L 10.00 C=120 PT 12.42 (105) Q 19.74 F=0 F 0.00 PE 0.00 EN T 10.00 0.1102 PF 1.10 20 101DQ 20.59 1.080 L 5.25 C=120 PT 13.52 (101) Q 40.33 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4133 PF 5.52 PT 19.36 ( 20) 8 7 7.758 L 220.00 C=150 PT 54.26 ( 7) Q 281.37 F=GV F 6.04 PE 0.00 LU T 226.04 0.0007 PF 0.16 3 8 7.758 L 158.00 C=150 PT 54.42 ( 8) Q 281.37 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0007 PF 0.17 1 3 7.758 L 1.00 C=150 PT 54.59 ( 3) Q 281.37 F=0 F 0.00 PE 0.00 LU T 1.00 0.0007 PF 0.00 PT 54.59 ( 1) SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #3 Carport .15/900 Location Flow Pipe Fittings in Size & From To GPM IN Devices 03-09-2002 PAGE 3 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 6 7 ------------------ 7.758 L 623.00 C=150 PT 54.26 ( 7) Q 124.84 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0001 PF 0.07 5 6 7.758 L 415.00 C=150 PT 54.33 ( 6) Q 124.84 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0001 PF 0.05 4 5 7.758 L 174.00 C=150 PT 54.38 ( 5) Q 124.84 F=0 F 0.00 PE 0.00 LU T 174.00 0.0001 PF 0.02 2 4 7.758 L 596.00 C=150 PT 54.40 C 4) Q 124.84 F=T,GV,4EE/GV,2E F 146.52 PE 0.00 LU T 742.52 0.0001 PF 0.07 1 2 7.758 L 1.00 C=150 PT 54.47 ( 2) Q 124.84 F=0 F 0.00 PE 0.00 LU T 1.00 0.0001 PF 0.00 ------------------ PT 54.47 ( 1) 22 23 2.203 L 12.50 C=120 PT 17.56 ( 23) Q 38.32 F=0 F 0.00 PE 0.00 FM T 12.50 0.0117 PF 0.15 21 22DQ 38.49 2.203 L 12.50 C=120 PT 17.71 ( 22) Q 76.81 F=0 F 0.00 PE 0.00 FM T 12.50 0.0423 PF 0.53 20 21DQ 39.08 2.203 L 12.50 C=120 PT 18.24 ( 21) Q 115.89 F=0 F 0.00 PE 0.00 FM T 12.50 0.005 PF 1.13 18 20DQ 40.33 2.203 L 90.00 C=120 PT 19.37 ( 20) Q 156.21 F=T,8E/T F 61.60 PE -0.87 FM T 151.60 0.1572 PF 23.83 17 18 2.203 L 63.00 C=120 PT 42.33 ( 18) Q 156.21 F=T/T F 23.20 PE 0.00 FM T 86.20 0.1572 PF 13.55 16 17 3.314 L 20.00 C=120 PT 55.88 ( 17) Q 156.21 F=8E F 58.40 PE 0.87 FM T 78.40 0.0215 PF 1.69 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa Greens Building #3 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 15 16 3.314 L 116.00 C=120 PT 58.44 ( 16) Q 156.21 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0215 PF 3.21 11 15 3.314 L 7.58 C=120 PT 61.65 ( 15) Q 156.21 F=CV,E F 28.85 PE 3.28 FR T 36.43 0.0215 PF 0.78 10 11 4.280 L 7.00 C=140 PT 65.71 ( 11) Q 156.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0047 PF 0.12 9 10 4.266 L 37.00 C=150 PT 65.83 ( 10) Q 156.21 F=T F 38.42 PE 0.00 UN T 75.42 0,0Q42 PF 0.32 7 9 4.266 L 71.00 C=150 PT 66.15 ( 9) Q 156.21 F=T,GV,DDC/3E F 99.89 PE -27.30 UN T 170.89 0.0042 PF 0.72 4" Watts 909 RPDA 14.69 ------------------ PT 39.57 ( 7) 0 1 7.758 L 1.00 C=150 PT 54.57 ( 1) Q 406.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PF 0.00 PT 54.57 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1945 Dove Lane Building: New System No. 2-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP4 Construction: Combustible El Non-Combustible Ceiling Height 8'-O" Ft. SYSTEM DESIGN NFPA 13: El Light 'Hazard Ordinary Hazard Group El 1 El 2 El 3 El Extra Hazard [1 NFPA 231 El NFPA 231C: Figure: Curve: El Other (Specify) Specific Ruling Residential Made By Date Area of Sprinkler Operation 2-head System Type Density .10 Wet El Dry El Deluge El Pre-Action Area Per Sprinkler 20' x 20' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 40.21 PSI Required 56.22 At City Connection "C" Factor Used: Overhead 120 Underground 150 Water Flow Test Pump Data Tank or Reservoir Date 8 Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 W.ii Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Class Location - Area Aisle Width % Palletized % Rack Commodity Storage Height Storage Method: Solid Piled Rack El Single Row El Conventional Pallet []Double Row El Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided El Automatic Storage El Encapsulated. El Solid Shelving El Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. Sigma Dynamic, Corporation 7700 Supply! Demand Graph Margin Pressure 21.73 PSI Flow 2647.70 GPM - . 0 --- - - - - • ____ _____ _____ ______ 5 -.--,.-- 0 200 400 600 000 1000 1200 1400 1600 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand Additional Flows Hose at Source Total Demand 43.06 PSI • 40.21 GPM 0.00 GPM 0.00 GPM 43.06 PSI a 40.21 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI @ 1480.00 GPM Elevation 0.00 PSI La Costa Greens Bldg #3 2-head calc 12 11 Ii IC IC 6 6 7 S S S 5 4 4 3 3 2 OLf 03-09-2002 PAGE 1 SUMITTAL SERIAL NO:2932HY4 La Costa Greens Building #3 third floor 2-head calculation 20' x 20' spacing FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 40.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 162 20.00 20.00 4.90 16.66 163 20.21 20.00 4.90 17.02 64.79 PSI TOTAL WATER REQUIRED FOR SYSTEM TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 150 TO 151 40.21 GPM 40.21 GPM 43.06 PSI 0.00 PSI 13.55 FPS 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 161 162 1.101 L 13.00 C=150 PT 16.66 (162) Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 PT 17.95 (161) 161 163 ------------------ 1.101 L 7.50 C=150 PT 17.02 (163) Q 20.21 F=DPV,E F. 6.00 PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.00 C=150 PT 17.96 (161) Q 40.21 F=E F 5.00 PE 0.22 BN1 T 7.00 0.2477 PF 1.73 153 160 1.101 L 32.00 C=150 PT 1.9.91 (160) Q 40.21 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 BN1 T 54.00 0.2477 PF 13.38 PT 33.29 (153) 150 151 ------------------ 1.101 L 1.75 C=150 PT 46.72 (151) Q 40.21 F=T/E F 10.00 PE 0.32 EN T 11.75 0.2477 PF 2.91 PT 49.95 (150) 8 7 ------------------ 7.758 L 220.00 C=150 PT 43.06 ( 7) Q 28.25 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 43.06 ( 8) Q 28.25 F=GV,EE/GV,T F 78.57 PE 0.00 LU . T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 43.06 ( 3) Q 28.25 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 43.06 ( 1) 6 7 ------------------ 7.758 L 623.00 C=150 PT 43.06 ( 7) Q 11.97 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 5 6 7.758 L 415.00 C=150 PT 43.06 ( 6) Q 11.97 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 4 5 7.758 L 174.00' C=150 PT 43.06 ( 5) Q 11.97 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #3 third floor 2-head calculation 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 2 4 7.758 L 596.00 C=150 PT 4.06 ( 4) Q 11.97 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 43.06 ( 2) Q 11.97 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 ------------------ PT 43.06 C 1) 152 153 1.101 L 10.00 C=150 PT 33.28 (153) Q 40.21 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.2477 PF 2.72 151 152 1.101 L 9.00 C=150 PT 4033 (152) Q 40.21 F=DPV F 1.00 PE 3.90 FRI T 10.00 0.2477 PF 2.48 ---------------- PT 46.71 (151) 18 150 2.203 L 63.00 C=120 PT 4.9.95 (150) Q 40.21 F=T,8E F 50.00 PE -0.87 FM T 113.00 0.0128 PF 1.45 17 18 2.203 L 63.00 C=120 PT 50.53 ( 18) Q 40.21 F=T/T F 23.20 PE 0.00 FM T 86.20 0.0128 PF 1.10 16' 17 3.314 L 20.00 C=120 PT 51.63 ( 17) Q 40.21 F=8E F 58.40 PE 0.87 FM T 78.40 0.0017 PF 0.13 15 16 3.314 L 116.00 C=120 PT 52.63 ( 16) Q 40.21 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0017 PF 0.25 11. 15 3.314 L 7.58 C=120 PT 52.88 ( 15) Q 40.21 F=CV,E F 28.85 PE 3.28 FR T 36.43 0.0017 PF 0.06 10 11 4.280 L 7.00 C=140 PT 56.22 ( 11) Q 40.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0004 PF 0.01 9 10 4.266 L 37.00 C=150 PT 56.23 ( 10) Q 40.21 F=T F 38.42 PE 0.00 UN T 75.42 0.0003 PF 0.02 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa Greens Building #3 third floor 2-head calculation 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 7 9 4.266 L 71.00 C=150 PT 56.25 ( 9) Q 40.21 F=T,GV,DDC/3E F 99.89 PE -27.30 UN T 1.70. 89 0.0003 PF 0.05 4" Watts 909 RPDA 14.02 PT 29.00 ( 7) ------------------ 0 1 7.758 L 1.00 C150. PT 43.06 ( 1) Q 40.2.1 F=0 F 0.0 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 43.06 C 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1945 Dove Lane Building: New System No. 1-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP4 Construction: 0 Combustible [1 Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIGN NFPA 13: El Light Hazard Ordinary Hazard Group El 1 El 2 0 3 El Extra Hazard []NFPA 231 El NFPA 231C: Figure: Curve: El Other (Specify) ZSpecffic Ruling Residential Made By Date Area of Sprinkler Operation 1-head System Type Density .10 Wet 0 Dry C] Deluge 0 Pre-Action Area Per Sprinkler 18' x 18' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 17.68 PSI Required 31.73 At City Connection "C" Factor Used: Overhead 120 Underground 150 !YJ' I :*i ii 'J !1 IMA Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department U WWI UJ1X1II Commodity Storage Height Storage Method: Solid Piled Class Area % Palletized Location - Aisle Width % Rack Rack El Single Row 0 Conventional Pallet El Double Row [] Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided El Automatic Storage El Encapsulated El Solid Shelving El Non Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg #3 1-head Caic Sigma Dynemica Corporation 7700 8uDolv I Demand Graph -1 Margin Pressure 48.57 PSI Flow 4131.60 GPM - - JO FO - - 105 2o 400 600 800 1000 1200 1400 1600 1600 20 Water Flow (GPM) System Demand.. Sprinkler Demand Additional Flows Hose at Source Total Demand 16.22 PSI 0 17.68 GPM 0.00 GPM 0.00 GPM 16.22 PSI 1 17.68 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI @ 1480.00 GPM Elevation 0.00 PSI SUMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 1 La Costa Greens Building #8 third floor 1-head calculation FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 164 17.68 17.00 4.90 13.02 TOTALS WATER. REQUIRED FOR, SYSTEM 17.68 GPM TOTAL WATER REQUIREMENT 17.68 GPM PRESSURE REQUIRED AT 0 16.22 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0. 00 PSI MAXIMUM VELOCITY FROM 150 TO 151 5.96 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #8 third floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices. Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV/2E F 11.00 PE 0.22 AO T 24.0,01 0.0542 PF 1.30 153 160 1.101 L 32.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 BN1 T 54.00 0.0542 PP 2.93: PT 1.7.47 (153) ------------------ 150 151 1.101 L 1.75 C=150 PT 26.83 (151) Q 17.68 F=.T/E F 10.00 PE. 0.32 B T 11.75: 0.0542 PP 0.64. PT 27.79 (150) ------------------ 8 7 7.758 L 2:20.00; Q=1.50 PT 16.2:2 ( 7) Q 13.36 F=GV F 6.04 PE: 0.00 LU T 226.04 0.0000 PF 0.00 3. 8 7.758 L 158:.00: C=150; PT' 16.22 ( 8) Q 13.36 F=GV,EE/GV,T F 78.57 PEI 0 00 LU T 236.57 0.0000 PF 0.00 1 3. 7.758 L. 1.00 C=11,50' PT 16.2,2 ( 3) Q 13.3.6 F=0 F' 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 16.22 ( 1) ------------------ 6 7 7.758: L 623:.0:0 C=.150 PT 16.22( 7); Q 4.32 F=EE.,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 5 6 7.75.8 L 415.0:0 C=150 PT 16.22. C 6) Q 4.32 F=GV,.2E:E:/2E:E F .6.0.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 4 5 7.758 L 174.00 C=150 PT 16.22 C 5) Q 4.32 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 2 4 7.758 L 596.00 C=150 PT 16.22 ( 4) Q 4.32 F=T,GV,4EE/GV2E:E: F 1.46.52 PE: 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 16.22 C 2) 4.32 F=0 F 0.00 FE 0.00 LU T 1.00 0.0000 PF -0.00 PT 16.22 ( 1) 9900°Tl SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #8 third floor 1-head calculation Location Flow Pipe Fittings Equiv in Size & Length From To GPM IN Devices Ft 03-09-2002 PAGE 3 Friction Pressure Loss Summary PSI/Ft PSI 152 153 ------------------ 1.101 L 10.00 C=150 PT 17.46 (153) Q 17.68 F=DPV F 1.00. PE 4.33 FRi T 11.00 0.0542 PF 0.60 151 152 1.101 L 9.00 C=150 PT 22.39 (152) Q 17.68 F=DPV F 1.00 PE 3.90 FRI T: 10.00 0.0542 PF 0.54 PT 26.83 (151) 18 150 2.203 L 63.00 C=120 PT 27.79 (150) Q 17.68 F=T,. 8E F 50.00 PE; -0.. 87 FM T 113.00 0.0028 PF 0.32 17 18 2.203 L 63.00 C=120 PT 27.24 ( 18) Q 17.68 F=T/T F 23.20 PE 0.00 FM T 86 .20 0. 0028 PP 0.24 16 17 3.314 L 20.00 C=120 PT 27.48 ( 17) Q 17.68 F=8E F 58.40 PE 0.87 S FM T 78.40 0.0004 PF 0.03 15 16 3.314 L 116.00 C=120 PT 28.38 ( 16) Q 17.68 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0004 PF 0.06 11 15 3.314 L 7.58 C=120 PT 28.44 ( 15) Q 17.68 F=cV,E F 28.85 PE 3.28 FR T 36.43 0.000:4 PF 0.01 10 11 4.280 L 7.00 C=140 PT 31.73 ( 11) Q 17.68 F=E F 17.92 PE 0.00 UN T 24.92 0.0001 PF 0.0.0 9 10 4.266 L 37.00 C=150 PT 31.73 ( 10) Q 17.68 F=T F 38.42 PE 0.00 UN T 75.42 0.0001 PP 0.01 7 9 4.266 L 71.00 C=150 PT 31.74 ( 9) Q 17.68 F=TGV,DDC/3E F 99.89 PE -27.30 UN T 170.89 0.0001 PP 0.02 • 4" Watts 909 RPDA 11.77 PT 4.46 ( 7) 0 1 7.758 L 1.00 C=150 PT 16.2.2 ( 1) Q 17.68 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 • PT 16.22 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 9 FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1933 Dove Lane Building: #6 System No. Carport Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: 0 Combustible El Non-Combustible Ceiling Height 8'-O" Ft. SYS1tM IJtS1(i1N NFPA 13: El Light Hazard Ordinary Hazard Group 1 2113 El Extra Hazard El NFPA 231 E] NFPA 231C: Figure: Curve: El Other (specify) Area reduced per NFPA 13 Section 7-2.3.2.4 []Specific Ruling Made By Date Area of Sprinkler Operation 900 sq ft System Type Density .15 Z Wet El Dry El Deluge El Pre-Action Area Per Sprinkler 125 sq ft Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside 250 Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 (S)SJ'l ,;• '1 GPM Required 15 8. 10 PSI Required 65.69 At City Connection "C" Factor Used: Overhead 120 Underground 150 'Li I a .iiuI J J WA Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMOL)I1Y SIUKAUE Commodity Class Location - Storage Height Area. Aisle Width Storage Method: Solid Piled % Palletized %Rack Rack El Single Row El conventional Pallet El Double Row El Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided El AutOmatic Storage El Encapsulated El Solid Shelving El Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. - La Costa Greens Bldg #6 Carport .15/900 Sigma Dynamic* Corporation 7700 Supply I Demand Graph I" margin Pressure 1.85 PSI 1 Flow 430.75 GPM ____ _____ _____ _____ ______ ______ ______ _______ 05 95 90 75 70 - - 55• -z, so C ao 10 200 400 600 800 1000 1200 N1 1400 1600 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand 61.95 PSI 1 158.10 GPM Additional Flows 250.00 GPM Hose at Source 0.00 GPM Total Demand 62.28 PSI 0 408.10 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI e 1480.00 GPM 03-08-2002 PAGE 1 SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #6 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 408.1 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 22.13 18.25 5.60 15.62 102 20.24 18.25 5.60 13.06 103 19.31 18.25 5.60 11.89 104 19.05 18.25 5.60 11.57 105 21.22 18.25 5.60 14.36 106 19.39 18.25 5.60 11.99 107 18.50 18.25 5.60 10.92 108 18.25 18.25 5.60 10.62 64.14 PSI TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 15 TO 16 158.10 GPM 250.00 GPM 408.10 GPM 62.28 PSI 0.00 PSI 21.63 FPS SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 2 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 104 108 1.080 L 10.00 C=120 PT 10.62 (108) Q 18.25 F=0 F 0.00 PE 0.00 BN T 10.00 0.0953 PF 0.95 23 104DQ 19.05 1.080 L 5.25 C=120 PT 11.57 (104) Q 37.30 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3577 PF 4.78 PT 16.67 ( 23) ------------------ 103 107 1.080 L 10.00 C=120 PT 10.92 (107) Q 18.50 F=0 F 0.00 PE 0.00 BN T 10.00 0.0978 PF 0.98 22 103DQ 19.31 1.080 L 5.25 C=120 PT 11.90 (103) Q 37.81 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3669 PF 4.90 PT 17.12 ( 22) ------------------ 102 106 1.080 L 10.00 C=120 PT 11.99 (106) Q 19.39 F=0 F 0.00 PE 0.00 BN T 10.00 0.1067 PF 1.07 21 102DQ 20.24 1.080 L 5.25 C=120 PT 13.06 (102) Q 39.63 F=T,E F 8.10 PE 0.32 EN T 13.35 0.4002 PF 5.34 PT 18.72 ( 21) ------------------ 101 105 1.080 L 10.00 C=120 PT 14.36 (105) Q 21.22 F=0 F 0.00 PE 0.00 BN T 10.00 0.1260 PF 1.26 20 101DQ 22.13 1.080 L 5.25 C=120 PT 15.62 (101) Q 43.36 FT,E F 8.10 PE 0.32 EN T 13.35 0.4725 PF 6.31 PT 22.25 ( 20) ------------------ 5 4 7.758 L 174.00 C=150 PT 61.88 ( 4) Q 156.14 F=0 F 0.00 PE 0.00 LU T 174.00 0.0002 PF 0.03 6 7.758 L 415.00 C=150 PT 61.91 ( 5) Q 156.14 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0002 PF 0.10 7 6 7.758 L 623.00 C=150 PT 62.01 ( 6) Q 156.14 F=EE,GV,'EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0002 PF 0.14 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 7 7.758 L 220.00 C=150 PT 62.15 ( 7) Q 156.14 F=GV F 6.04 PE 0.00 LU T 226.04 0.0002 PF 0.05 3 8 7.758 L 158.00 C=150 PT 62.20 ( 8) Q 156.14 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0002 PF 0,05 1 3 7.758 L 1.00 C=150 PT 62.25 ( 3) Q 156.14 F0 F 0.00 PE 0.00 LU T 1.00 0.0002 PF 0.00 PT 62.25 ( 1) 2 4 ------------------ 7.758 L 596.00 C=150 PT 61.88 ( 4) Q 251.96 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0005 PF 0.37 1 2 7.758 L 1.00 C=150 PT 62.25 ( 2) Q 251.96 F=0 F 0.00 PE 0.00 LU T 1.00 0.0005 PF 0.00 PT 62.25 ( 1) 22 23 ------------------ 1.728 L 12.17 C=120 PT 16.67 ( 23) Q 37.30 F=0 F 0.00 PE 0.00 FM T 12.17 0.0363 PF 0.44 21 22DQ 37.81 1.728 L 12.17 C=120 PT 17.11 ( 22) Q 75.12 F=0 F 0.00 PE 0.00 FM T 12.17 0.1324 PF 1.61 20 21DQ 39.63 1.728 L 12.17 C=120 PT 18.72 ( 21) Q 114.75 F=0 F 0.00 PE 0.00 FM T 12.17 0.2900 PF 3.53 16 20DQ 43.36 1.728 L 41.50 C=120 PT 22.25 ( 20) Q 158.10 F=T F 9.00 PE 0.00 FM T 50.50 0.5246 PF 26.49 15 16 1.728 L 11.50 C=120 PT 48.74 ( 16) Q 158.10 F=2E F 7.40 PE 0.00 FM T 18.90 0.5246 PF 9.91 11 15 2.203 L 7.58 C=120 PT 58.65 ( 15) Q 158.10 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.1608 PF 3.76 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 4 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 10 11 4.280 L 7.00 C=140 PT 65.69 ( 11) Q 158.10 F=E F 17.92 PE 0.00 UN T 24.92 0.0048 PF 0.12 9 10 4.266 L 118.00 C=150 PT 65.81 ( 10) Q 158.10 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0043 PF 0.92 4 9 4.266 L 79.00 C=150 PT 66.73 ( 9) Q 158.10 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0043 PF 0.77 4" Watts 909 RPDA 14.74 PT 47.13 ( 4) ------------------ 0 1 7.758 L 1.00 C=150 PT 62.28 ( 1) Q 408.10 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PF 0.00 PT 62.28 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 9 FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1933 Dove Lane Building: #6 System NO 2-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: 0 Combustible El Non-Combustible Ceiling Height 8'-O" Ft. SYSTEM DESIGN NFPA 13: El Light Hazard Ordinary Hazard Group El 1 0 2 El 3 El Extra Hazard [1 NFPA 231 F] NFPA 231C: Figure: Curve: El Other (Specify) S ZSpecific Ruling Residential Made By Date Area of Sprinkler Operation 2-head System Tvie Density .10 Z Wet El Dry El. Deluge El Pre-Action Area Per Sprinkler 20' x 20' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 40.21 PSI Required 55.49 At City Connection "C" Factor Used: Overhead 120 Underground 150 WATER SuPPlY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack El Single Row El Conventional Pallet El Double Row El Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided El Automatic Storage [1 Encapsulated El Solid Shelving El Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg #6 2-head caic Sigma Dynamics Corporation 7700 8uDolvl Demand GraDh 149 120---- I15------------- -I Margin 1W ____ ____ _____ _____ ______ ______ ______ Pressure 15.50 PSI —j Flow 2199.63 GPM 105 100 80 76- 70 6-0 55 ------- - 60. 45 40 35 1 3( 111 21 cc 200 400 600 800 1000 1200 1400 1600 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand 49.29 PSI e 40.21 GPM Additional Flows 0.00 GPM Hose at Source 0.00 GPM Total Demand 49.29 PSI e 40.21 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI e 1480.00 GPM SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 40.2 GPM 64.79 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 162 20.21 20.00 4.90 17.02 163 20.00 20.00 4.90 16.66 TOTAL WATER REQUIRED FOR SYSTEM 40.21 GPM TOTAL WATER REQUIREMENT 40.21 GPM PRESSURE REQUIRED AT 0 49.29 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 150 TO 151 13.55 FPS 03-08-2002 PAGE 1 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 2 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 161 163 1.101 L 13.00 C=150 PT 16.66 (163) Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 PT 17.95 (161) 161 ------------------ 162 1.101 L 7.50 C=150 PT 17.02 (162) Q 20.21 F=DPV,E F 6.00 PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.50 C=150 PT 17.96 (161) Q 40.21 F=T/E F 10.00 PE 0.22 BN1 T 12.50 0.2477 PF 3.10 152 160 1.101 L 33.00 C=150 PT 21.28 (160) Q 40.21 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T 66.00 0.2477 PF 16.35 ------------------ PT 37.63 (152) 150 151 1.101 L 1.75 C=150 PT 44.67 (151) Q 40.21 F=T/E F 10.00 PE 0.32 BN T 11.75 0.2477 PF 2.91 ------------------ PT 47.90 (150) 5 4 7.758 L 174.00 C=150 PT 49.29 ( 4) Q 15.23 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 49.29 ( 5) Q 15.23 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 49.29 ( 6) Q 15.23 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 49.29 ( 7) Q 15.23 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 49.29 ( 8) Q 15.23 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 49.29 ( 3) Q 15.23 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 49.29 ( 1) SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 2 ------------------ 4 7.758 L 596.00 C=150 PT 49.29 ( 4) Q 24.98 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 49.29 ( 2) Q 24.98 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 ------------------ PT 49.29 ( 1) 151 152 1.101 L 10.00 C=150 PT 37.61 (152) Q 40.21 F=DPV F 1.00 PE 4.33 FR]. T 11.00 0.2477 PF 2.72 PT 44.66 (151) 16 ------------------ 150 1.728 L 68.00 C=120 PT 47.91 (150) Q 40.21 F=T F 9.00 PE 0.00 FM T 77.00 0.0417 PF 3.21 15 16 1.728 L 11.50 C=120 PT 51.12 ( 16) Q 40.21 F=2E F 7.40 PE 0.00 FM T 18.90 0.0417 PF 0.79 11 15 2.203 L 7.58 C=120 PT 51.91 ( 15) Q 40.21 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0128 PF 0.30 10 11 4.280 L 7.00 C=140 PT 55.49 ( 11) Q 40.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0004 PF 0.01 9 10 4.266 L 118.00 C=150 PT 55.50 ( 10) Q 40.21 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0003 PF 0.06 4 9 4.266 L 79.00 C=150 PT 55.56 ( 9) Q 40.21 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0003 PF 0.05 4" Watts 909 RPDA 14.02 PT 35.24 ( 4) 0 3. 7.758 L 1.00 C=150 PT 49.29 ( 1) N Q 40.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 49.29 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1933 Dove Lane Building: #6 System No. Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. Construction: X Combustible El Non-Combustible Ceiling Height SYSTEM DESIGN NFPA 13: 0 Light Hazard Ordinary Hazard Group El NFPA 231 El NFPA 23 1C: Figure: [I] Other (Specify) - Li Specific Ruling Residential Made By Date Area of Sprinkler Operation 1-head System Type Density .10 Z Wet El Dry El Deluge El Pre-Action Area Per Sprinider 18'x 18' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinider Allowance n/a Temperature Rating 155 GPM Required 17.68 PSI Required 28.22 At City Connection "C" Factor Used: Overhead 120 Underground 150 'LV N '.1.i U2ft' Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department I UKRUt Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack 1 2El3 Curve: 1-head FP7 8'-O" Ft. El Extra Hazard Rack El Single Row El Conventional Pallet El Double Row 0 Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided 0 Automatic Storage El Encapsulated El Solid Shelving 0 Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. C., 1111 a_a-a-a- 0000 OD o00 (000(0 r%ccr 14 to (1) IL a. (0 (0 (0 (0 0) 0) 14 14 CD IV 0 LA 0 Lw)co 'UwO c— Q.Li. - 0 1 - - - N 1 - -- - ---------- 1 C - --- - ------i - ---- - ------- 0 - - C --- - - a e Ia 0 N ('1 - - 10 0 10 0 0 0) 0 10 0) CO a io 0 a to CD i'- - to 10 to a to a .o to CO a to ') 01 to a a 01 SUMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 1 La Costa Greens Building #6 second floor 1-head calculation FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 164 17.68 17.00 4.90 13.02 TOTAL WATER REQUIRED FOR SYSTEM 17.68 GPM TOTAL WATER REQUIREMENT 17.68 GPM PRESSURE REQUIRED AT 0 19.66 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 150 TO 151 5.96 FPS SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 2 La Costa Greens Building #6 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV,2E F 11.00 PE 0.22 AO T 24.00 0.0542 PF 1.30 152 160 1.101 L 33.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T 66.00 0.0542 PF 3.58 PT 18.12 (152) 150151 1.101 L 1.75 C=150 PT 23.04 (151) Q 17.68 F=T/E F 10.00 PE 0.32 EN T 11.75 0.0542 PF 0.64 PT 24.00 (150) ------------------ 7.758 L 174.00 C=150 PT 19.66 ( 4) Q 6.06 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 19.66 ( 5) Q 6.06 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 19.66 ( 6) Q 6.06 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 19.66 ( 7) Q 6.06 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 19.66 ( 8) Q 6.06 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 19.66 ( 3) Q 6.06 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 ------------------ PT 19.66 ( 1) 2 4 7.758 L 596.00 C=150 PT 19.66 ( 4) Q 11.62 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 / 1 2 7.758 L 1.00 C=150 PT 19.66 ( 2) Q 11.62 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 19.66 ( 1) SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #6 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 151 152 ------------------ 1.101 L 10.00 C=150 PT 18.11 (152) Q 17.68 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.0542 PF 0.60 PT 23.04 (151) 16150 ------------------ 1.728 L 68.00 C=120 PT 24.00 (150) Q 17.68 F=T F 9.00 PE 0.00 FM T 77.00 0.0091 PF 0.70 15 16 1.728 L 11.50 C=120 PT 24.70 ( 16) Q 17.68 F=2E F 7.40 PE 0.00 FM T 18.90 0.0091 PF 0.17 11 15 2.203 L 7.58 C=120 PT 24.87 ( 15) Q 17.68 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0028 PF 0.07 10 11 4.280 L 7.00 C=140 PT 28.22 ( 11) Q 17.68 F=E F 17.92 PE 0.00 UN T 24.92 0.0001 PF 0.00 9 10 4.266 L 118.00 C=150 PT 28.22 ( 10) Q 17.68 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0001 PF 0.02 4 9 4.266 L 79.00 C=150 PT 28.24 ( 9) Q 17.68 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0001 PF 0.02 4" Watts 909 RPDA 11.77 PT 7.89 ( 4) 0 1 ------------------ 7.758 L 1.00 C=150 PT 19.66 ( 1) Q 17.68 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 19.66 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR; STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1929 Dove Lane Building: #7 System No. Carport Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: Combustible U Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIGN NFPA 13: El Light Hazard Ordinary Hazard Group M 1 El 2 [1 3 Li Extra Hazard 0 NFPA 231 El NFPA 231C: Figure: Curve: El Other (Specify) Area reduced per NFPA 13 Section 7-2.3.2.4 El Specific Ruling. Made By Date Area of Sprinkler Operation 900 sq ft System Type - Density .15 JZ Wet El Dry El Deluge LI Pre-Action Area Per Sprinkler 125 sq ft Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside 250 Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 158.10 PSI Required 63.26 At City Connection "C" Factor Used: Overhead 120 Underground 150 WATPR SuPPlY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack 0 Single Row El Conventional Pallet LI Double Row 0 Slave Pallet 0 Multiple Row LI Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided O Automatic Storage 0 Encapsulated O Solid Shelving 0 Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg #7 Carport .15/900 7700 Supply! Dmend Graph Sigma Dynamic. Corporation - - - - 20 - - - - - - ____ _____ ______ ______ _______ _______ ________ ________ ___________________ _j Margin 15 ____ ____ _____ _____ ______ ______ _______ _______ I Pressure 4.86 PSI Flow 874.96 GPM 05 - - - - - - ____ _____ ______ ______ _______ _______ ________ ________ ________ _________ 7-- 0 95 90 85 75 ago -- so jis 1(Dy iof 5 200 400 600 800 1000 1200 N1-86 1400 1600 1600 20 Water Flow (GPM) System Demand.. Sprinkler Demand 58.93 PSI I 158.10 GPM Additional Flows 250.00 GPM Hose at Source 0.00 GPM Total Demand 59.27 PSI 0 408.10 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI I 1480.00 GPM 125 SUMITTAL SERIAL NO:2932HY4 La Costa Greens Building #7 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 408.1 GPM 03-09-2002 PAGE 1 64.14 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 22.13 18.25 5.60 15.62 102 20.24 18.25 5.60 13.06 103 19.31 18.25 5.60 11.89 104 19.05 18.25 5.60 11.57 105 21.22 18.25 5.60 14.36 106 19.39 18.25 5.60 11.99 107 18.50 18.25 5.60 10.92 108 18.25 18.25 5.60 10.62 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 16 TO 20 158.10 GPM 250.00 GPM 408.10 GPM 59.27 PSI 0.00 PSI 21.63 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #7 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 104 108 1.080 L 10.00 C=120 PT 10.62 (108) Q 18.25 F=0 F 0.00 PE 0.00 BN T 10.00 0.0953, PF 0.95 23 104DQ 19.05 1.080 L 5.25 C=120 PT 11.57 (104) Q 37.30 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3577 PF 4.78 PT 16.67 ( 23) 103 ------------------ 107 1.080 L 10.00 C=120 PT 10.92 (107) Q 18.50 F=0 F 0.00 PE 0.00 BN T 10.00 0.0978 PF 0.98 22 103DQ 19.31 1.080 L 5.25 C120 PT 11.90 (103) Q 37.81 F=T,E F 8.10 PE 0.32 EN T 13.35 0.3669 PF 4.90 PT 17.12 ( 22) 102 ------------------ 106 1.080 L 10.00 C=120 PT 11.99 (106) Q 19.39 F=0 F 0.00 PE 0.00 EN T 10.00 0.1067 PF 1.07 21 102DQ 20.24 1.080 L 5.25 C=120 PT 13.06 (102) Q 39.63 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4002 PF 5.34 PT 18.72 ( 21) 101 ------------------ 105 1.080 L 10.00 C=120 PT 14.36 (105) Q 21.22 F=0 F 0.00 PE 0.00 BN T 10.00 0.1260 PF 1.26 20 101DQ 22.13 1.080 L 5.25 C=120 PT 15.62 (101) Q 43.36 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4725 PF 6.31 ------------------ PT 22.25 ( 20) 5 4 7.758 L 174.00 C=150 PT 58.86 ( 4) Q 156.14 F=0 F 0.00 PE 0.00 LU T 174.00 0.0002 PF 0.03 6 5 7.758 L 415.00 C=150 PT 58.89 ( 5) Q 156.14 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0002 PF 0.10 7 6 7.758 L 623.00 C=150 PT 58.99 ( 6) Q 156.14 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0002 PF 0.14 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #7 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 7 7.758 L 220.00 C=150 PT 59.13 ( 7) Q 156.14 F=GV F 6.04 PE 0.00 LU T 226.04 0.0002 PF 0.05 3 8 7.758 L 158.00 C=150 PT 59.18 ( 8) Q 156.14 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0002 PF 0.05 1 3 7.758 L 1.00 C=150 PT 59.23 ( 3) Q 156.14 F=0 F 0.00 PE 0.00 LU T 1.00 0.0002 PF 0.00 PT 59.23 ( 1) 2 ------------------ 4 7.758 L 596.00 C=150 PT 58.86 ( 4) Q 251.96 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0005 PF 0.37 1 2 7.758 L 1.00 C=150 PT 59.23 ( 2) Q 251.96 F=0 F 0.00 PE 0.00 LU T 1.00 0.0005 PF 0.00 PT 59.23 ( 1) 22 ------------------ 23 1.728 L 12.17 C=120 PT 16.67 ( 23) Q 37.30 F=0 F 0.00 PE 0.00 FM1 T 12.17 0.0363 PF 0.44 21 22DQ 37.81 1.728 L 12.17 C120 PT 17.11 ( 22) Q 75.12 F=0 F 0.00 PE 0.00 FM1 T 12.17 0.1324 PF 1.61 20 21DQ 39.63 1.728 L 12.17 C=120 PT 18.72 ( 21) Q 114.75 F=0 F 0.00 PE 0.00 FM1 T 12.17 0.2900 PF 3.53 16 20DQ 43.36 1.728 L 36.00 C=120 PT 22.25 ( 20) Q 158.10 F=T F 9.00 PE 0.00 FM1 T 45.00 0.5246 PF 23.61 15 16 2.203 L 50.00 C=120 PT 45.86 ( 16) Q 158.10 F=3E F 14.40 PE 0.00 FM T 64.40 0.1608 PF 10.36 11 15 2.203 L 7.58 C=120 PT 56.22 ( 15) Q 158.10 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.1608 PF 3.76 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa Greens Building #7 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 10 11 4.280 L 7.00 C=140 PT 63.26 ( 11) Q 158.10 F=E F 17.92 PE 0.00 UN T 24.92 0.0048 PF 0.12 9 10 4.26,6 L 24.00 C=150 PT 63.38 ( 10) Q 158.10 F=T/E F 57.63 PE 0.00 UN T 81.63 0.0043 PF 0.35 4 9 4.266 L 79.00 C=150 PT 63.73 ( 9) Q 158.10 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0043 PF 0.77 4" Watts 909 RPDA 14.74 PT 44.13 ( 4) 0 1 7.758 L 1.00 C=150 PT 59.27 C 1) Q 408.10 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PF 0.00 PT 59.27 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, A 92056 (760) 806-9997 9 FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24A)4 Location: 1929 Dove Lane Building: #7 System No. 2 -head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. - P7 Construction: 0 Combustible [1 Non-Combustible Ceiling Height Ft. SYSTEM DESIGN NFPA 13: D Light Hazard Ordinary Hazard Group D 1 [1 [1 NFPA 231 1] NFPA 231C: Figure: [J Other (Specify) Specific Ruling Residential Made By 2 0 3 Curve: 1] Extra Hazard Date, Area of Sprinkler Operation 2-head Density .10 Area Per Sprinkler 20' x 20' Hose Allowance GPM: Inside 0 Hose Allowance GPM: Outside Rack Sprinkler Allowance n/a System Tvpi ro Wet E] Dry [1 Deluge Sprinkler or Nozzle Make Tyco Model Size 1/2" K-Factor: 49 Temperature Rating 155 0 Pre-Action LFII CALCULATION SUMMARY GPM Required 40.21 "C" Factor Used: PSI Required 55.27 Overhead 120 At City Co Underground nection 150 WATFPcTTPPIV Water Flow Test Date & Time 10/17/03 10:45am Static PSI 72 Residual PSI 64 GPM Flowing 1480 Elevation 190' Pump Data Rated Capacity n/a At PSI n/a Elevation n/a Tank Proof Flow i /a Capacity n/a or Reservoir Elevation n/._________________ Well GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department UMMU UI! Y S I UKAUt Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack O Single Row 0 Conventional Pallet 0 Double Row [] Slave Pallet 0 Multiple Row Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided O Automatic Storage [I] Ei [II] Solid Shelving 0 N Ft. I In. La Costa Greens Bldg #7 2-head caic Sigma Dynamics Corporation 7700 Aunn1w I Ommand Granh ILU - 120 - - - - - - __ ___ ___ ___ ___ ____ ____ ____ _______________ 15 -I Margin - - - - - - ____ ____ _____ _____ ______ ______ _______ _______ Pressure 15.76 PSI Flow 2219.77 GPM IOE 00 95 - - - - - - 90 - 75 70 65. 6c • • _________ 45 40 35 31 2 2j 7 :TF-Iii 200 400 600 800 1000 1200 1400 1600 1800 20' Water Flow (GPM) System Demand.. Sprinkler Demand Additional Flows Hose at Source Total Demand 49.03 PSI 49.03 PSI & 40.21 GPM 0.00 GPM 0.00 GPM 40.21 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI 1480.00 GPM SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 1. La Costa Greens Building #7 second floor 2-head calculation 20' x 20' Spacing FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 40.2 GPM 64.79 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 162 20.00 20.00 4.90 16.66 163 20.21 20.00 4.90 17.02 TOTAL WATER REQUIRED FOR SYSTEM 40.21 GPM TOTAL WATER REQUIREMENT 40.21 GPM PRESSURE REQUIRED AT 0 49.03 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 150 TO 151 13.55 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #7 second floor 2-head calculation 201 x 20' Spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 161 162 1.101 L 13.00 C=150 PT 16.66 (162) Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 PT 17.95 (161) ------------------ 161 163 1.101 L 7.50 C=150 PT 17.02 (163) Q 20.21 F=DPV,E F 6.00 PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.50 C=150 PT 17.96 (161) Q 40.21 F=T/E F 10.00 PE 0.22 BNl T 12.50 0.2477 PF 3.10 152 160 1.101 L 33.00 C=150 PT 21.28 (160) Q 40.21 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T 66.00 0.2477 PF 16.35 PT 37.63 (152) ------------------ 150 151 1.101 L 1.75 C=150 PT 44.67 (151) Q 40.21 F=T/E F 10.00 PE 0.32 BN T 11.75 0.2477 PF 2.91 -- PT 47.90 (150) 5 4 - 7.758 L 174.00 C=150 PT 49.03 ( 4) Q 15.23 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 49.03 ( 5) Q 15.23 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 49.03 ( 6) Q 15.23 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 49.03 ( 7) Q 15.23 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 49.03 ( 8) Q 15.23 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 49.03 ( 3) Q 15.23 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 49.03 ( 1) SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #7 second floor 2-head calculation 20' x 20' Spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 2 4 7.758 L 596.00 C=150 PT 49.03 ( 4) Q 24.98 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 49.03 ( 2) Q 24.98 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 49.03 ( 1) 151 ------------------ 152 1.101 L 10.00 C=150 PT 37.62 (152) Q 40.21 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.2477 PF 2.72 ------------------ PT 44.67 (151) L6 150 1.728 L 62.00 C=120 PT 47.91 (150) Q 40.21 F=T F 9.00 PE 0.00 FM1 T 71.00 0.0417 PF 2.96 15 16 2.203 L 50.00 C=120 PT 50.87 ( 16) Q 40.21 F=3E F 14.40 PE 0.00 FM T 64.40 0.0128 PF 0.82 11 15 2.203 L 7.58 C=120 PT 51.69 ( 15) Q 40.21 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0128 PF 0.30 10 11 4.280 L 7.00 C=140 PT 55.27 ( 11) Q 40.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0004 PF 0.01 9 10 4.266 L 24.00 C=150 PT 55.28 ( 10) Q 40.21 F=T/E F 57.63 PE 0.00 UN T 81.63 0.0003 PF 0.02 4 9 4.266 L 79.00 C=150 PT 55.30 ( 9) Q 40.21 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0003 PF 0.05 4" Watts 909 RPDA 14.02 ------------------ PT 34.98 ( 4) 0 1 7.758 L 1.00 C=150 PT 49.03 ( 1) Q 40.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 49.03 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: f929F Dove Lane Building: #7 System No. 1-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: Combustible LI Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIGN NFPA 13: LI Light Hazard Ordinary Hazard Group [I] NFPA 231 LI NFPA 23 1C: Figure: [] Other (Specify) Specific Ruling Residential Made By 1 LI 2 LI 3 LI Extra Hazard Curve: Date Area of Sprinkler Operation 1-head System Type Density .10 Z Wet LI Dry LI Deluge LI Pre-Action Area Per Sprinkler 18' x 18' Sprinkler orNozzle Hose Allowance GPM: Inside 0 V Make Tyco Model LF1I Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 17.68 PSI Required 28.18 At City Connection "C" Factor Used: V Overhead 120 Underground 150 'L'd I VANII Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane V Source of Information Carlsbad Fire Department COMMOUflY STORAOE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack LI Single Row LI Conventional Pallet LI Double Row LI Slave Pallet LI Multiple Row LI Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided 0 Automatic Storage LI Encapsulated LI Solid Shelving LI Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens bldg #7 1-head cab Sigma Dynemlo. Corporation 7700 Supply I Demand Graph 20 IS —j Margin - - - - - - u.' I Pressure 45.20 PSI Flow 3973.21 GPM ____ ____ _____ ______ ______ ______ ______ _______ 05 DO 95 ---- DO 85 BC zz 50 46 40 WO 400 600 800 1000 1200 1400 ______________________ 1600 N16 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand Additional Flows Hose at Source Total Demand 19.60 PSI 19.60 PSI 17.68 GPM 0.00 GPM 0.00 GPM 0 17.68 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI 1480.00 GPM SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 1 La Costa Greens Building #7 second floor 1-head calculation FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 164 17.68 17.00 4.90 13.02 TOTAL WATER REQUIRED FOR SYSTEM 17.68 GPM TOTAL WATER REQUIREMENT 17.68 GPM PRESSURE REQUIRED AT 0 19.60 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 150 TO 151 5.96 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #7 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV/2E F 11.00 PE 0.22 AO T 24.00 0.0542 PF 1.30 152 160 1.101 L 33.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T 66.00 0.0542 PF 3.58 PT 18.12 (152) 150 151 ------------------ 1.101 L 1.75 C=150 PT 23.04 (151) Q 17.68 F=T/E F 10.00 PE 0.32 BN T 11.75 0.0542 PF 0.64 ------------------ PT 24.00 (150) 5 4 7.758 L 174.00 C=150 PT 19.60 C 4) Q 6.06 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 19.60 ( 5) Q 6.06 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 19.60 ( 6) Q 6.06 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 19.60 ( 7) Q 6.06 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 19.60 ( 8) Q 6.06 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 19.60 ( 3) Q 6.06 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 19.60 ( 1) 2 4 7.758 L 596.00 C=150 PT 19.60 ( 4) Q 11.62 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 19.60 ( 2) Q 11.62 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 19.60 ( 1) SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #7 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 151 152 ------------------ 1.101 L 10.00 C=150 PT 18.11 (152) Q 17.68 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.0542 PF 0.60 ------------------ PT 23.04 (151) 16 150 1.728 L 62.00 C=120 PT 24.00 (150) Q 17.68 F=T F 9.00 PE 0.00 FM1 T 71.00 0.0091 PF 0.65 15 16 2.203 L 50.00 C=120 PT 24.65 ( 16) Q 17.68 F=3E F 14.40 PE 0.00 FM T 64.40 0.0028 PF 0.18 11 15 2.203 L 7.58 C=120 PT 24.83 ( 15) Q 17.68 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0028 PF 0.07 10 11 4.280 L 7.00 C=140 PT 28.18 ( 11) Q 17.68 F=E F 17.92 PE 0.00 UN T 24.92 0.0001 PF 0.00 9 10 4.266 L 24.00 C=150 PT 28.18 ( 10) Q 17.68 F=T/E F 57.63 PE 0.00 UN T 81.63 0.0001 PF 0.01 4 9 4.266 L 79.00 C=150 PT 28.19 ( 9) Q 17.68 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0001 PF 0.02 4" Watts 909 RPDA 11.77 PT 7.84 ( 4) 0 1 7.758 L 1.00 C=150 PT 19.60 ( 1) Q 17.68 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 19.60 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1925 Dove Lane Building: #8 System No. Carport Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP8 Construction: N Combustible El Non-Combustible Ceiling Height 8'-O" Ft. SYSTEM DESIGN NFPA 13: [1 Light Hazard Ordinary Hazard Group 0 NFPA 231 [1 NFPA 23 1C: Figure: [I] Other (Specify) Area reduced per NFPA 13 Section 7-2.3.2.4 [1 Specific Ruling Made By 102 El 3 Extra Hazard Curve: Date Area of Sprinkler Operation 900 sq ft System Type - Density .15 Wet El Dry El Deluge [1 Pre-Action Area Per Sprinkler 125 sq ft Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside 250 Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 LtSIJJ. I GPM Required 156.21 PSI Required 65.71 At City Connection "C" Factor Used: Overhead 120 Underground 150 AMA I WAN II !J !J WA Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 1045am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department A-110V b!. Iii PJUW&.1 II) 1..1[I1 Commodity -- Storage Height Storage Method: Solid Piled Class Area % Palletized Location - Aisle Width % Rack Rack El Single Row 0 Conventional Pallet 0 Double Row 0 Slave Pallet El Multiple Row El. Open Flue Spacing In Inches Longitudinal . Transverse - Horizontal Barriers Provided 0 Automatic Storage El Encapsulated 0 Solid Shelving El Non-Encapsulated Clearance From To of Storage to Ceiling Ft. In. igma Dynamics Corporation La Costa Greens Bldg #8 Carport 15/900 7700 Supply I Demand Graph 12 :Margin II) ] Pressure 1.70 PSI Flow GPM _4O4.69 1 0 i IIIIIi __JiiiiiiIJiIiii IIITE - - 400 60CF 1000 1200 1400 1600 1000 2000 Water Flow (GPM) system Demand.. Water Supply.. pr1k1er Demand 62.10 PSI @ 156.21 GPM Static 64.80 PSI dcUtIona1 Flows 250.00 GPM Residual 57.60 PSI a 1480.00 GPM Hose at Source 0.00 GPM Elevation 0.00 PSI lotal Demand 62.44 PSI € 406.21 GPM SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #8 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 406.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL. MINIM. SPR, FLOW; FLOW K-FACTOR PRESSURE 101 20.59 18.75 5.60 13.52 102 1.9.96 1.8.75 5.60 12.70 103.19.65. 18.75 5.601 12.32 104 19.57 18.75 5.60 12.21 105 19.74 18.75 5.60 12.42 106 19.12 18...75 5.60 11.66 107 18.83 18.75 5.60 11.31 108 18.75 18.75 5.60 11.21 03-09-2002 PAGE 1 64.14 PSI TOTAL WATER. REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 20 T0101 1516.21. GPM 250.00: GPM 406.21 GPM 62.44 PSI 0.00 PSI 14. 12 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #8 carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From. To GPM IN Devices Ft. PSI/Ft. PSI 104 108 1.080 L 10.00 C=120 PT 11.21 (108) Q 18.75 F=0 F 0.00 PE 0.00 BN T 10.00 0.1002 PP 1.00 23 104DQ 19.57 1.080 L 5.25 C=120 PT 12.21 (104) Q 38.32 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3760 PF 5.02 PT 17.55 ( 23) 103107 -- 1.080 L 10.00 C=120 PT 11.31 (107) Q 18.83 F=0 F 0.00 PE 0.00 BN T 10.00: 0.1010 PF 1.01 22 103DQ 19.65 1.080 L 5.25 C=120 PT 12.32 (103) Q 38.49 F=T,E F 8.10 PE 0.32 BN T 13.3.5 0.3790 PF 5.06 PT 17.70 ( 22) 102 106 1.080 L 10.00 C=120 PT 11.66 (106) Q 19.12 F0 F 0.00 PE 0.00 EN T 10.00 0.1039 PF 1.04 21 102DQ 19.96 1.080 L 5.25 C=120 PT 12.70 (102) Q 39.08 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3900 PF 5.21 PT 18.23 ( 21) 101 105 1.080 L 10.00 C=120 PT 12.42 (105) Q 19.74 F=0 F 0.00 PE 0.00 BN T 10.00 0.1102 PF 1.10 20 101DQ 20.59 1.080 L 5.25 C120 PT 13.52 (101) Q 40.33 F=T,E F 8.10 PE 0.32 EN T 13.35 0.4133 PF 5.52 PT 19.36 ( 201 5 4 7.758 L 174.00 C=150 PT 62.03 ( 4) Q 155.42 F=0 F 0.00 PE 0.00 LU T 174.00 0.0002 PF 0.03 6 5 7.758 L 415.00 C=150 PT 52.06 ( 511 Q 155.42 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0002 PF 0.10 7 6 7.758 L 623.00 C=150 PT 62.16 ( 6) Q 155.42 F=EE,GV/EE,Gv,2EE F 66.44 PE 0.00 LU T 689.44 0.0002 PF 0.14 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #8 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM, IN Devices Ft PSI/Ft PSI 8 7 7.758 L 220.00 C=150 PT 62.30 ( 71 Q 155.42 F=GV F 6.04 PE 0.00 LU T 226.04 0.0002 PF 0.05 3 8 7.758 L 158.00 C150 PT 62.35 ( 8) Q 155.42 F=GV,BB/GV,T F 78.57 PE 0.00 LU T 236.57 0.0002 PF 0.05 1 3 7.758 L 1.00 C150 PT 62.40 ( 3) 0 155.42 F=0 F 0.00 PE 0.00 LU T 1.00 0.0002 PP 0.00 ------------------ PT 62.40 ( 1) 2 4 7758 L 596.00 C=150 PT 62.03 ( 4) Q 250.79 FT,GV,4EE/GV,2EE F 146.52 PB 0.00 LU T 742.52 0.0005 PF 0.37 1 2 7.758 L 1.00 C=150 PT 62.40 ' 2) Q 250.79 F=0 F 0.00 PE 0.00 LU T 1.00 0.0005 PP 0.00 PT 62.40 ( 1) 22 23 2.203 L 12.50 C=120 PT 17.56 C 23) Q 38.32 F=0 F 0.00 PB 0.00 FM T 12.50 0.0117 PF 0.15 21 22DQ 38.49 2.203 L 12.50 Cr120 PT 17,71 ( 22) Q 76.81 F=0 F 0.00 PE 0.00 FM T 12.50 0.0423 PF 0.53 20 21DQ 39.08 2.203 L 12.50 0120 PT 18.2:4 C 21) Q 115.89 F=0 F 0.00 PE 0.00 FM T 12.50 0.0905 PP 1.13 18 20DQ 40.33 2.203 L 90.00 C=120 PT 19.37 ( 20) Q 156.21 F=T,8E/T F 61.60 PE -0.87 FM T 151.60 0.1572 PF 23.83 17 18 2.203 L 63.00 C=120 PT 4233 18) Q 156.21 F=T/T F 23.20 PE 0.00 FM T 86.20 0.1572 PF 13.55 16 17 3.314 L 20.00 C=12(D PT 55.88 ( 17) Q 156.21 F=EE F 58.40 PE 0.87 FM T 78.40 0.0215 PF 1.69 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa .Greens Building #8 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 15 16 3.314 L 116.00 C=120 PT 58.44 1 16) Q 156.21 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0215 PF 3.21 ii 1 1z1 T. I P r- P, D9"i ( Q 156.21 F=CV,E F 28.85 PE 3.28 FR T 36.4.3 0.0215 PP 0.78 In Ii ii Ifl T. '7 flfl r-ILn Drn c '- I iii Q 156.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0047 PF 0.12 9 10 4.256 L 23.00 C150 PT 65.83 1 10) Q 156.21 F=T F 38.42 PE 0.00 UN T 6.1.42 0.0042 PP 0.26 4 9 4.266 L 79.00 C150 PT 66.09 1 9) Q 156.21 F=T,GV,DDC/3E F 99.89 PE -1950 rp t ) r t ii V. -J 4" Watts 909 RPDA 14.69 4------------------ /'i' 4/34 j '77 P T. Q 406.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PP 0.00 PT 62.44 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1925 Dove Lane Building: 18 System No. Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. Construction: 0 Combustible El Non-Combustible Ceiling Height SYSTEM DESIGN l NFPA 13: 0 Light Hazard Ordinary Hazard Group 1 2 03 El NFPA 231 D NFPA 23IC: Figure: Curve: E] Other (Specify) ISpecific Ruling Residential Made By Date Area of Sprinkler Operation 2-head System Type Density .10 Z Wet 0 Dry El Deluge U Pre-Action Area Per Sprinkler 20' x 20' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 40.21 PSI Required 56.22 At City Connection "C" Factor Used: Overhead 120 Underground 150 WATER SIJPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack 2-head FP8 8'-O" Ft. [1 Extra Hazard Rack El Single Row 0 Conventional Pallet 0 Double Row 0 Slave Pallet U Multiple Row U Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided El Automatic Storage El Encapsulated 0 Solid Shelving El Non-Encapsulated Clearance From Toi, of Storage to Ceiling Ft. - In. La Costa Greens Bldg #8 2-head caic Sigma Dynemlos Corporation 7700 Supply I Demand Graph Margin I Pressure 13.93 PSI LFlow 2074.28 GPM -U-- __ I 4.00 (00 600 1000 1200 1400 1600 1800 M1.B5 2000 Water Flow (GPM) System Dernand. nk I r Demand o-'iiddit ional Flows Hlose at Source Totit Demand 50.86 PSI @ 40.21 GPM 0.00 GPM 0.00 GPM 50.86 PSI @ 40.21 GPM Water Supply.. Static 64.80 PSI Residua l 57.60 PSI e 1480.00 GPM E levation 0.00 PSI SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 1 La Costa Greens Building 48. third floor 2-head calculaton 20' x 20' spacing FLOW TEST RESULTS Water Supply STATIC. 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 40,.2t GPM 64.79 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 162 20.00 20.00 4.90 16.66 163 20.21 20.00 4.90 17.02 TOTAL WATER REQUIRED FOR SYSTEM 40.21 GPM TOTAL WATER REQUIREMENT 40.21 GPM PRESSURE REQUIRED AT 0 50:..86?PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 000 PSI MAXIMUM VELOCITY FROM 150 TO 151 '13.55 FPS SUBMITTAL SERIAL NO:2932HY4 V 03-09-2002 PAGE 2 La Costa Greens Building *8 third floor 2-head. calculat.on 20 x 20' spacing V Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft. PSI/Ft PSI 161 162 1.101 L 13.00 C=150 PT 16.66 Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 PT 17.95 (161) ------------------ 161 163 1.101 L 7.50 C=150 PT 17.02 Q 20.21 F=DPV,E F 6.00 PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.00 C150 PT 17.96 (161) Q 40.21 F=E F 5.00 PE 0.22 BN1 T 7.00 0.2477 PF 1.73 1:53 160 1.101 L 32.00 C=150 PT Qc1 Q 40.21 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 BNi T 54.00 0.2477 PP 13.38 ------------------ PT 33.29 (153) 150 151 1.101 L 1.75 C=150 PT 46.72 (151) Q 40.21 F=T /E F 10.00 PB 0.32 BN T 11.75 0.2477 PF 2.91 ------------------- PT 49.95 (150) 5 4 7.758 L 174,00 C=150 Q 15.23 F=0 F 0.00 . PE 0.00 LU T 174.00 0.0000 PF 0.00 1 50 0 15.23 F=GV,2EE/2EE F 6.0.40 PE 0.00 LU. T 475.40 0.0000 PF 0.00 - r . r r C=150 nP7 =n b) Q 15.23 F=EE,GV/EE,Gv,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PP 0.00 P 70 C - Li .__-i ,LD r .3. J Li . ,J \ / Q 15.23 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PP 0.00 3 8 7.758 L 158.00 C=150 PT 50.85 ( 8) Q 15.23 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PP 0.00 1 3 7.758 L I ...C=150 PT Q 15.23 F=0 F 0.00 PE 0.00 T TI n.1% '.3 'J i . . Li Li PT 50.85 ( 1) SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #8 third floor 2-head calculaton 20' x 20' spacing Location Flow Pipe Fittings Equiv in Size & Length From To GPM IN Devices Ft 03-09-2002 PAGE 3 Friction Pressure Loss Summary PSI/Ft PSI 2 4 ------------------ 7.758 L 596.00 C=150 PT 50.85 1 4) Q 24.98 FT 1 GV4EEGV2EE F 14(03.52 FE 0.00 LU T 742.52 0.0000 PF 0.00 1 ) 7 flU C=1fl PT ( 7) Q 24.98 F0 F 0.00 FE 0.00 LU T 1.00 0.0000 PF 0.00 ------------------ PT 50.85 ( 1) 152 153 1.101 L 10.00 C=150 PT 33.28 (153) Q 40.21 F=DPV F 1.00 FE 4.33 FR! T 11.00 0.2477 PF 2.72 11 1. Q rr r=r, PT 41! Q 40.21 F=DPV F 1.00 FE 3.90 T IU.UU PT 46.71 (151) 18 150 2.203 L 63.00 C=120 PT 49.95 (150) Q 40.21 F=T8E F 50.00 FE -0.87 FM T 113.00 0.0128 PP 1.45 Q 40.21 F=T/T F 23.20 FE 0.00 FM T 86.20 0.0128 PP 1.10 . u - Q 40.21 F=8E F 58.40 FE 0.87 FM T 78.40 0.0017 PF 0.13 15 14 3.314 L 11400 C120 PT 5263 1 14) Q 40.21 F=2E/T F 33.50 FE 0.00 FM T 149.50 0.0017 PP 0.25 11 15 3 314 L 7.58 C120 PT 51.85 1 15) Q 40.21 F=cV,E F 28.85 FE 3.28 FR T 36.43 0.0017 PF 0.05 . 25: 2 24 Ci PT Q 40.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0004 PP 0.01 9 10 4.266 L 2 --- .ljo C=150 PT 5423 10) Q 40.21 F=T F 38.42 PE 0.00 UN T 61.42 0.0003 PF 0.02 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa Greens Building #8 third floor 2-head calculaton 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 4 9 4.266 L 79.00 C150 PT 56.25 Q 40.21 F=T,GV,DDC/3E F 99.89 PE -19.50 UN T 178.89 0.0003 PF 0.05 4" Watts 909 RPDA 14.02 ------------------ rr DC OP. 0 1 7.758 L 1.00 C=150 PT 50.86 ( Q 40.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 50.86 ( 0) Rack LI Single Row LI] Conventional Pallet LI] Double Row [J Slave Pallet LI Multiple Row 0 Open Flue Spacing In Inches Longitudinal Transverse LI] Automatic Storage 0 Solid Shelving 0 Encapsulated O Non Encapsulated Clearance From Top of Storage to Ceiling Ft. In. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 9 FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1925 Dove Lane Building: #8 System No. 1-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP8 Construction: N Combustible [1 Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIGN NFPA 13: D Light Hazard Ordinary Hazard Group D 1 [1] 2 D 3 0 Extra Hazard L]NFPA 231 D NFPA 231C: Figure: Curve: [1 Other (Specify) Specific Ruling Residential Made By Date Area of Sprinkler Operation 1-head. - - System Type Density .10 Wet LI Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 18' x 18' Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 GPM Required 17.68 PSI Required 31.73 At City Connection "C" Factor Used: Overhead 120 Underground 150 WAlER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 1045am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department %'%JiVJL1VxV.U't A I a I .)iitji::. Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Horizontal Barriers Provided La Costa Greens Bldg #8 1-head calc Sigma Dynemlos Corporation T700 Supply / Demand Graph Margin Prs1uri 40,77 PSI Flow 3757.39 GPM N t - ___ _____ N15 200 400 600 600 1000 120 1400 1600 1800 2000 Water Flow (GPM) ystenri Demand.. Water Supply.. prnker Demand 24.02 PSI @ 17.68 GPM Static 64.80 PSI O"Iddit i onal Flows 0.00 GPM Residual 57.60 PSI e 1480.00 GPM o;e at Source 0.00 GPM Elevation 0.00 PSI I otall Demand 24.02 PSI e 17.68 GPM SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 1 La Costa Greens Building #8 third floor 1-head calculation FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 164 17.68 17.00 4.90 13.02 TOTAL WATER REQUIRED FOR SYSTEM 17.68 GPM TOTAL WATER REQUIREMENT 17.68 GPM PRESSURE REQUIRED AT 0 24.02 PSI MAXIMUM PRES SURE UNBALANCE: IN LOOPS 0.00 Psi MAXIMUM VELOCITY FROM 150 TO 151 5.96 FPS SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #8 third floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV/2E F 11.00 PE 0.22 AO T 24.00 0.0542 PF 1.30 153 160 1.101 L 32.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 BNi T 54.00 0.. 0542: PF 2.93 ------------------ PT 17.47 (153) 150 151 1.101 L 1.75 C=150 PT 26.83 (151) Q 17.68 F=T/E F 10.00 PE 0.32 BN T 11.75 0.0542 PF 0.64 ------------------ PT 27.79 (150) 5 4 7.758 L 174.00 C=150 PT 24.02( 4) Q 6 . 06 F=0 F 0. 00 PE 0. 00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 24.02 ( 5) Q: 6.06 F=GV,2EE:/2EE F 60.40 PE (.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 24.02( 61 Q 6.06 F=EE:,GV/EE,GV,2EE: F 661.44 PEI 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L: 2120.0€: C150 PT 2,4:.,02, ( 7) Q 6.0:6 F=GV F 6.04. PE: 0.0:0 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 24.02 ( 8) Q 6.06 F=GV,EE/GV,T Ft 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3. 7.75.8 L 1.00 =150 PT 24.02 ( 3) Q 6.061 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 24.02 ( 1) 2 4 7.758 L 596.00 C=150 PT 24.02 C 4) Q 11.62 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 24.02 C 2) Q 11.62 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 24.02 ( 1) I SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #8 third floor 1-head calculation Location Flow Pipe Fittings Equiv in Size & Length From To GPM IN Devices Ft 03-09-2002 PAGE 3 Friction Pressure Loss Summary PSI/Ft PSI 152 153 ------------------ 1.101 L 10.00 C=150 PT 17.46 (153) Q 17.68 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.0542 PF 0.60 151 152 1.101 L 9.00 C=150 PT 22.39 (152) Q 17.68 F=DPV F 1.00 PE 3.90 FRi T 10.00 0.0542 PF 0.54 PT 26.83 (151) 18 150 2.203 L 63.00 C=120 PT 27.79 (150) Q 17.68 F=T8E F 50.00 PE -0.87 FM T 113.00 0.0028 PF 0.32 17 18 2.203 L 63.00 C=120 PT 27.24 C 18) Q 17.68 F=T/T F 23.20 PE 0.00 FM T 86.20 0.0028 PF 0.24 16 17 3.314 L 20.00 Cr120 PT 27.48 C 17) Q 17.68 F=8E F 58.40 PE 0.87 FM T 78.40 0.0004 PF 0.03 15 16 3.314 L 116.00 C=120 PT 28.38 C 1611 Q 17.68 F=2E/T F 33.50 PE 0.00 FMI T 149.50 0.0004 PF 0.06 11 15 3.314 L 7.53 C=120 PT 28.44 1 151 Q 17.68 F=CV,E F 28.85 PE 3.28 FR T 36.43 0.0004 PF 0.01 10 11 4.280 L 7.00 C=140 PT 31.73 1 ii) O 17.68 F=E F 17.92 PE 0.00 UN T 24.92 0.0001 PF 0.00 9 10 4.266 L 23.00 C=150 PT 31.73 1 10) O 17.68 FT F 38.42 PE 0.00 UN T 61.42 0.0001 PF 0.01 4 9 4.266 L 79.00 C=150 PT 31.74 1 9) O 17.68 F=T,GV,DDC/3E F 99.89 PE -19.50 UN T 17889 00001 PF 0.02 413 Watts 909 RPDA 11.77 ------------------ 'r 1Z.b 4; 0 1 7758 L 1.00 C150 PT 24.02 C 1) Q 17.68 F=0 F 0.00 PE 0.00 UN T 1.00 0,0000 PF 0.00 PT 24.02 ( 0)