Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2501 EL CAMINO REAL; 240; FA150020; Permit
City of Carlsbad Fire Alarm Permit Permit No: FA1 50020 2501 ELCAMINO2A Job Address: Status: APPROVED REAL Permit Type: FALARM Applied 4/6/2015 Parcel No: 1563020800 Approved: 4/6/2015 Lot #: 0 Reference No.: Issued: 4/6/2015 PC #: Inspector: Project Title: LUNA GRILL PROVIDE AND INSTALL NOTIFICATION AND MONITORING AS SHOWN ON DRAWINGS, CONNECT TO EXISTING FACP. Applicant: SIMPLEX GRINNELL 3568 RUFFIN ROAD SOUTH SAN DIEGO CA 858-583-0426 Owner: CMFPCRLLC C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940 DEPT WFLD CARLSBAD, CA ( IIFees ($) Add'I Fees ($) 1. Total Balance _____ 0 _ SimplexGrinnell BE SAFE. SimplexGrinnell LP 3568 Ruffin Road San Diego, CA 92123-2597 Tele: (858) 633-9100 A Tyco International Company Fax: (858) 633-9101 www.simplexgrinnell.com Fire Alarm Product Submittal PROJECT: WESTFIELD CARLSBAD tuna Grill Unit #240 2501 EL CAMINO REAL CARLSBAD, CA 92008 These plans has c beeti eviess rd or itipite itt cipitatn_e svitit the CtIrreill a1,'thie codes irtd si edaiti in lircc the urtilictsn. Tltr- on ncr ot (nitttitc or mo tttiiiie liii' reics iii sitpla)o nil iii I )ltniilln ii nit 1 hitittittint perttnt 'n tilt the espreir and cii tidlind lint this ten new lo rel , ~, rs tue onniter in rnmttir n_time 5 nil ettetiteer or architect Cot sole _spmitsnlitinv Fr lull uniuinpinaniec with said cnnies intl stularn_Is nninlnlit the hnikiutt cattle or hnr ttuv r pnmnsihilt mw drttn:neurs. merits. intlssumnts M uegIleiuce ill these mm tether or tot noted lit this review. RECmMMENI) API'ROVAI. RhC(.)lMENi) Al'bRO\'Ai AS rs(,)T)-" 1) For any questions regarding this submittal, please contact Douglas Daniels @ 858-633-9123 or ddaniets@simplexgrinnell.com FA1 50020 3/2/2015 REV.#: 0 PROJECT #: 480409161 - SimplexGrinnell LP SimplexGr:nnell BE SAFE. 3568 Ruffin Road San Diego, CA 92123-2597 Tele: (858) 633-9100 A Tyco International Company Fax: (858) 633-9101 www.simplexgrinnell.com Fire Alarm Certification Letter Fire Alarm System Products Qty- Model No Description C.S.F.M. No. E 4100-9111 Existing Voice Fire alarm control panel 7165-0026:251 E 4009-9201 Nac Booster Panel 7300-0026:214 2 4090-9001 Supervised lAM 7300-0026:223 4 4098-9756 Duct Smoke Detector 3240-0026:241 4 2098-9806 Remote Test Tastion 7300-0026:150 4 4098-9843 PAM-SD Relay 7300-1004:101 5 4906-9154 Multi-CD spkr/visual, white, ceiling 7320-0026:247 2 4906-9104 Multi-CD Visual, white, ceiling 7125-0026:316 2 SPWK Outdoor Speaker, white, wall 7320-1653:201 3/2/2015 REV.#: 0 PROJECT #: 480409161 £L5implEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I1iii*i Master Controller (top) bay: 32-Bit Master Controller with color-coded operator interface including raised switches for high confidence feedback Dual configuration program CPU, convenient service port access, and capacity for up to 2000 addressable points CPU assembly includes dedicated compact flash memory for on-site system information storage System power supply (SPS) and charger (9 A total) with on-board: NACs, IDNet addressable device interface, programmable auxiliary output and alarm relay Available with InfoAlarm Command Center expanded content user interface (see data sheet S4100-0045) Upgrade kits are available for existing control panels Standard addressable interfaces include: IDNet addressable device interface with 250 points that support TrueAlarm analog sensing and operate with either shielded or unshielded twisted pair wiring Remote annunciator module support via RIJI (remote unit interface) communications port Optional modules include: Building Network Interface Module (BNEC) for Ethernet connectivity options (see data sheet S4100-006 1) TrueAlert addressable notification appliance power supplies with three, 3 A SLC outputs Additional IDNet and MAPNET II addressable device modules and IDNet/MAPNET II quad isolator modules IDNet+ output module with built-in quad isolator and enhanced operation for better retrofit to existing wiring (see data sheet S4100-0046) Fire Alarm Network Interfaces, DACTs, city connections, and up to five (5) RS-232 ports for printers and terminals IP communicator compatibility Alarm relays, auxiliary relays, additional power supplies, DC modules, N4C expansion modules Service modems, VESDA Air Aspiration Systems interface, ASHRAE BACnet Interface, TCP/IP Bridges LED/switch modules and panel mount printers Emergency communications systems (ECS) equipment; 8 channel digital audio or 2 channel analog audio Battery brackets for seismic area protection (see page 2) Compatible with Simplex® remotely located: 4009 IDNet NAC Extenders, up to ten per IDNet SLC TrueAlert Addressable Controllers 4I00ES and upgrade kits are UL Listed to: UL Std. 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UUKL) UL Std. 2017, Process Management Equipment (QVAX) Ut Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detector Monitor (UIJLH) TJLC Std. S527-99 4I00 Fire Control Panels Addressable Fire Detection and Control Basic Panel Modules and Accessories 4100ES Cabinets are Available with One, Two or Three Bays CPU provides dual configuration programs: Two programs allow for optimal system protection and commissioning efficiency with one active program and one reserve Downtime is reduced because the system stays running during download PC based programmer features: Convenient front panel accessed Ethernet port for quick and easy download of site-specific programming Modifications can be uploaded as well as downloaded for greater service flexibility AND, firmware enhancements are made via software downloads to the on-board flash memory irnrr0 0rriri 41 ODES Series Fire Detection and Control Panels provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. An on-board Ethernet port provides fast external system communications to expedite installation and service activity. Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files to meet NFPA 72 (National Fire Alarm and Signaling Code) requirements. Modular design. A wide variety of functional modules are available to meet specific system requirements. Selections allow panels to be configured for either Stand-Alone or Networked fire control operation. InfoAlarm Command Center options provide convenient expanded display content (detailed on data sheet S4100-0045). * See pages 5 and 6 for product that is UL or ULC listed and additonal listing information. This product has been listed by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:251(4100E5) and 7300-0026:0368(4009 TPS) for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4100-0031-20 9/2012 i r rn F : d1llr The Master Controller Bay (top) includes a standard multi-featured system power supply, the master controller board, and operator interface equipment. The Expansion Bays include a Power Distribution Interface (PDI) for new 4" x 5" flat design option modules and also accommodate 4100-style modules. The Battery Compartment (bottom) accepts two batteries, up to 50 Ah, to be mounted within the cabinet without interfering with module space. The following illustration identifies bay locations using a three bay cabinet for reference. N MM, VIN IN i r ni mu .iirwiiImimrjJ The latching dress panel (retainer) assembly easily lifts off for internal access NACs are mounted directly on power supply assemblies providing minimized wiring loss, compact size, and readily accessible terminations Packaging supports traditional 4100-style motherboard with daughter cards Modules are power-limited (except as noted, such as relay modules) The NEMA I box is ordered separately and available for early installation Doors are available with tempered glass inserts or solid; boxes and doors are available in platinum or red Boxes and door/retainer assemblies are ordered separately per system requirements; refer to data sheet S4100-0037 for details Operator In -II1F11I The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly Master controller with dual slot motherboard Typical bays with mixed module sizes ansion Bay 2 4100ES Module Bay Reference Mpchaniil flsrrinfinn Boxes can be close-nippled; each box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7-05 category D, requires 33 Ah or 50 Ah batteries with battery brackets as detailed on data sheet S2081-0019 2 Upload/Download Basic operator instructions Panel sounder Ethernet port access are printed on the interface (under sliding cover) mounting plate F;Ii'i'E:it: UTlTiu i illifidi IYj TrueAlarm individual analog sensing with front panel information and selection access "Dirty" lrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" TrueAlarm magnet test indication appears as distinct "test abnormal" message on display when in test mode TrueAlarm sensor peak value performance report "Install Mode" allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring "Recurring Trouble Filtering" allows the panel to recognize, process, and log recurring intermittent troubles (such as external wiring ground faults), but only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self-resetting test cycle S4100-0031-20 912012 Lti .r rra riii Convenient Status Information. With the locking door closed, the glass window allows viewing of the display, status LEDs, and available operator switches. Features include a two-line by 40-character, wide viewing angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control switches and allows further inquiry by scrolling the display for additional detail. SIX SYSTEM STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, ULC SYSTEMS 1 require designating remain on until reset: a Ground Fault Fire Alarm & Priority 2 Alarm, red LED indicator J Supervisory & Trouble, yellow LED Alarm Silenced, yellow LED / / AC Power, green LED (on for normal) Lti.ri *. Convenient and extensive operator information is provided using a logical, menu-driven display Multiple automatic and manual diagnostics for maintenance reduction Alarm and Trouble History Logs (up to 1300 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer Convenient PC programmer label editing Password access control FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priority 2 Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts THREE PROGRAMMABLE LEDs provide custom labeling, the top two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow Custom label insert 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first alarm until acknowledged ALARM SILENCE causes audible notification appliances to be silenced (depending on panel programming) typically after evacuation is complete and while alarm source is being investigated; may allow visible notification to continue (strobes still flashing) SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal I atenuow-ast Ground Fault C Manual Evac ty Disconnect Elevator Recall 0 Almost Dirty Ground Fault - Latch SYSTEM IS NORMAL 15 am THU 12-AF FIVE PROGRAMMABLE FUNCTION SWITCHES, each with a yellow LED indicator POINT STATUS ADDITIONAL FUNCTION I LCD NAVIGATION NUMERIC KEYPAD for CONTROL KEYS: KEYS: I CONTROL: point category and point Point Enable and Event Time Request I Menu selection selection (alphabet Disable More Information Request I Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position this time) Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode 3 S4100-0031-20 9/2012 ['i.] .fl .ii i r1 t1ir1 TiIT1 i.i'1Fi The 4100ES is compatible with an extensive list of remote peripheral devices including printers, CRT/keyboards (up to five total), and both conventional and addressable devices including TrueAlarm analog sensors. ryr i.-i.-.i 1 ri mri' r iiui I Overview. The 4100ES provides standard addressable device communications for IDNet compatible devices and accepts optional modules for communications with MAPNET II compatible devices. Using a two wire communications circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, conventional IDC zones, and sprinkler waterfiow switches can be interfaced to the addressable controller to communicate their identity and status. Addressability allows the location and condition of the connected device to be displayed on the operator interface LCD and on remote system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled and monitored with addressable devices. Addressable Operation. Each addressable device on the communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A operation are available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. IDNet Channel Capacity. The CPU bay system power supply (SPS) provides an IDNet signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. Additional IDNet circuit modules are available for 64, 127, or 250 addressable devices. lDNet/MAPNET II Communications wiring specifications. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference. Wiring Specifications Size 18 AWG (0.82 mm2 ) Type Preferred Shielded twisted pair (SIP) Acceptable* Unshielded twisted pair (UIP) Farthest Distance 126-250 Up to 2500 feet (762 m) from Control Panel Upto4000ft(1219 m) per Device load up to 125 Total Wire Length Allowed With T_ Taps _for Class B_Wiring Up to 10,000 It (3 km); 0.58 pF * Some applications may require shielded wiring. Review your system with your local Simplex product supplier. I r i 1 F rntrTtflT1 TrueAlert Power Supplies provides three, 3 A Signaling Line Circuits (SLCs) for controlling and powering addressable notification appliances. With addressable appliances, Class B wiring can be "T-tapped" for easier wiring and reduced wire run lengths. Appliances include horns, strobes, and combination units. For more detail, refer to data sheet S4009-0003. IT r- .v.mim.-i'-iiisi .xtuItT1 Addressable device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. (refer to data sheet S4098-0041 for details) TrueAlarm heat sensors can be selected for fixed temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to HVAC system problems. Readings can selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 4100ES IDNet address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet S4098-0024. Ifl TFi lDITA[i(IYj Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 5 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and when end of life is reached. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. S4100-0031-20 9/2012 N System Power Supply (Continued): Three, 3 A On-Board NACs, conventional reverse polarity operation; rated 3 A for Special Application appliances and 2 A for Regulated 24 DC power, with electronic control and overcurrent protection; selectable as Class B or Class A, and for synchronized strobe or SmartSync horn/strobe operation over two wires NACs can be selected as auxiliary power outputs derated to 2 A for continuous duty; the total auxiliary power output per SPS is limited to 5 A Battery Charger is dual rate, temperature compensated, and charges up to 50 Ah sealed lead-acid batteries mounted in the battery compartment (33 Ah for single bay cabinets); also is UL listed for charging up to 110 Ah batteries mounted in an external cabinet (see data sheet S2081-0012 for details) Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual NAC currents 2 A Auxiliary Power Output is selectable for detector reset, door holder, or coded output operation Auxiliary Relay is selectable as N.O. or N.C., rated 2 A @ 32 VDC, and is programmable as a trouble relay, either normally energized or normally de-energized, or as an auxiliary control Optional City Connect Module (4100-6031, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Optional Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC Master Controller Selection Information Master Controller and Expansion Bay Selection* (Canadian models have low battery cutout) r Model - Model Type and Listing - Description Supv. Alarm (4100-9111 120 VAC input L_ 4100ES Master Controller Assembly with LCD and operator interface, 9 A system power supply/battery charger (SPS), 250 point IDNet interface, 3 NACs, auxiliary relay, and external RUI communications interlace 373 mA 470 mA 4100-9112 English French 120 Canadian VAC, ULC 4100-9113 4100-9211 220-240 VAC Input LJ'.. 4100-9131 120 VAC Input UL 14100ES Master Controller Assembly, no display, no operator interface, 9 A system power supply/battery 363 mA 425 mA 4100-9132 English I 120 VAC 1 , Canadian ULC 4100-9133 French i charger (SPS), 250 point IDNet interface, 3 NACs, auxiliary relay, and external RUI communications interface 4100-9230 220-240 VAC Input UL 4100-9121 Redundant Master Controller, two bay assembly; top bay contains LCD and operator interlace, (not ULC CPU card assembly, and 4100ES, 9 A system power supply/battery charger (SPS); second bay 718 mA 937 mA listed) contains CPU card in Slot 2, and LCD and operator interface; 120 VAC, 60 Hz input; NOTE: RUI connections require use of 4100-1291 RUI expansion modules 4100-2300 Expansion Bay Assembly; order for each required expansion bay (not required for 4100-9121) 4100-2303 Legacy Module Stabilizer Bracket, used when expansion bays have legacy slot style modules Master Controller Upgrades for Existing 4100 Series Fire Alarm Control Panels* de "Panel Includes - 4100-7150 1000 pt 4100 (4100+) New Master Controller and 4I00ES user interface door assembly with Ethernet connection 4100-7152 512 pt 4100 Same as 4100-7150 plus includes a Universal Power Supply 4100-7158 1000 pt 4100 (4100+) New Master Controller with Ethernet Connection Upgrade Kit; for 4100+ without LCD and or 4100U operator interface, or 4100U with or without LCD and operator interlace Expansion Bay Upgrade Kit for mounting 4100ES style (4" x 5" modules) in existing 4100 style panels; 4100-2301 Note: When using this kit to upgrade a 4100+ transponder, a 4100-0620 Transponder Interface Card (TIC) is also required for communications to the 4100ES module * For InfoAlarm Command Center expanded content display products, refer to data sheet S4100-0045. (Continued onnext page) 5 S4100-0031-20 9/2012 [uIrIrn9mI11 Master Controller and Motherboard: Mounts in Slot 4 of a two slot motherboard (Slots 3 and 4 of the Master Controller Bay) and provides one Style 4 or Style 7, RUT communications channel, available at Slot 4 RUT communications controls up to 31 devices per master controller (on one or multiple RUT channels); devices include: MINIPLEX transponders, 4603-9101 LCD Annunciators, 4602-9101 Status Command Units (SCU), 4602-9102 Remote Command Units (RCU), 4602 Series LED Annunciator Panels, 4100 Series 24 110 and LED/Switch modules, and remote mount 4009 TPS units Up to four RUT channels are supported; use up to three 4100-1291 RUT expansion modules as required Optional Service Modem 4100-6030 mounts onto the master controller board with its own on-board connections Slot 3 of the motherboard is primarily for the 4100-6078 Network Interface Board with media modules, and secondarily for the 4100-6038 Dual RS-232 Board (4100-6038 is required for 2120 System connections) System Power Supply: (see page 8 for more detail) Rating is 9 A total with "Special Application" appliances; 4 A total for "Regulated 24 DC" appliance power Outputs are power-limited, except for the battery charger Provides system power, battery charging, auxiliary power, auxiliary relay, earth detection, on-board IDNet communications channel for 250 points, three on-board NACs, and provisions for either an optional City Connect Module or an optional Alarm Relay Module IDNet SLC Output provides Class B or Class A communications for up to 250 addressable devices (as described on page 4) Module Selection Information Master Controller Upgrades for Existing 4020 Series Fire Alarm Control Panel Model I Descnption 4020 Master Controller Upgrade to 4100ES; Includes New Master Controller with LCD & operator interface assembly, 4100-9833 8 VDC Converter and RUI Interface in a single bay cabinet with locking glass door and retainer; mounts as an adjunct panel close-nippled to existing 4020 cabinet; also includes 8 VDC box-to-box power and communications harness and solid filler panel for the existing 4020 Master Controller bay Communication Modules MoeI.Desdllr. For Master Controller; mounts in Slot 3 Modular Network Interface; each requires For Redundant Master Controller two media modules (below) Size 1 Slot 46 mA Su.Alarni 46 mA 4100-6078 4100-6061 i Slot 46 mA 46 mA 4100-6056 Wired Media Module Select two media cards as required; mounts on Fiber Optic Media Module 4100-6078 or 4100-6061 NA: 55 mA 55 mA 4100-6057 25 mA 25 mA 4100-6047 Building Network Interface Card (BNIC), refer to data sheet S4100-0061 for details 2 Blocks 291 mA 291 mA 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6078 or 4100-6061 Network Interface Card, requires telephone line connection N.A; 60 mA 60mA; 4100-1291 Remote Unit Interface Module (RU!); up to three maximum per control panel 1 Slot 85 mA 85 mA 4100-6030 Service Port Modem, local panel access only, mounts to Master Controller Module, requires telephone line connection, accesses same information as front panel port N.A. 70 mA 70 mA 4100-6031 Select one per SPS (fits on SPS) City Circuit, with disconnect switches I For use with SPS only, not RPS N. •' 20 mA 36 mA 4100- 6032 I City Circuit, w/o disconnect switches _______________________________________________________ ., NA.: 20 mA 36 mA 4100-6033 Alarm Relay, 3 Form C relays, 2 A @ 32 VDC; for SPS or RPS .':N.A 15 mA 37 mA 4100-6101 Physical Bridge, Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA 4100-6102 Physical Bridge, Class X, includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA 4100-6038 Dual Port RS-232 with 2120 interface (slot module) I 3 maximum of RS-232 type modules per panel 1 Slot 132 mA 132 mA 4100-6046 Dual Port RS-232 standard interface (4 x 5 module) i Block 60 mA 60 mA 4100-6045 Decoder Module 3 Slots 85 mA 163 mA 4100-6048 VESDA Aspiration System Interface 1 Slot 132 mA 132 mA 4100-6052 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per system; includes 2, 2080-9047 cables, 14 ft (4.3 m) long, RJ45 plug and spade lugs 1 Slot 30 mA 40 mA Expansion, System, Remote, and TrueAlert Power Supplies and Accessories (Canadian models have low battery cutout) Model Voltage/Listing 120 VAC UL Descnphon Expansion Power Supply (XPS); 9Aoutput, 3 built-in Class NB NACs; NAC operation is same as SPS, see page 5 for details Size 2 Blocks Supv 50 mA ATaTrm 50 mA 4100-5101 4100-5103 120 VAC, Canadian ULC 4100-5102 220-240 VAC UL 4100-5115 NAC Expansion Module, 3 NACs, Class A/B, mounts on XPS only 25 mA 25 mA 4100-5111 120 VAC UL Additional System Power Supply (SPS); 9 A power supply/charger with 250 point IDNet channel, 3 Class A/B NACs, add IDNet device currents separately 4 Blocks 175 mA 185 mA 4100-5112 120 VAC, Canadian ULC 4100-5113 220-240 VAC ijiI 4100-5125 120 VAC UL Remote Power Supply (RPS); 9 A power supply/charger similar to SPS except no IDNet channel or City Circuits; will accept one 4100-6033 4 Blocks 150 mA 185 mA 4100-5126 120 VAC, Canadian ULC 4100-5127 220-240 VAC UL 4100-5120 120 VAC UL TrueAlert Power Supply (TPS); 3 Class B SLCs rated 3 A each for up to 63 TrueAlert addressable (special application)appliances per channel, 189 per TPS; built-in battery charger; 2 A aux. power output; add device current separately (see S4009-0003 for details) 4 Blocks 88 mA ________ 100 mA 4100-5121 120 VAC, Canadian ULC 4100-5122 220-240 VAC UL 4100-5124 TrueAlert SLC Class A Adapter for all 3 SI-Cs, mounts on TPS only N.A. 10 mA 10 mA 4100-5152 12 VDC Power Option, 2Amaximum 1 Block 1.5Amaximum 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum 1 Block included wlloads 4009-9813 4009 TPS Transponder Interface Card (TIC), mounts in a remote cabinet with TPS; order card, TPS, and batteries separately, and select a 2975-9229 (red) or 2975-9230 (beige) cabinet (field installed); refer to data sheet S4100-0037 for cabinet detail; Supervisory and Alarm current = 87 mA; (CSFM listed under 7300-0026:0368) 4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet 4100-0638 1 4100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from SPS 8 Zone Initiating Device Circuits* Madol TjV' S, Alir 4100-5005 1ClassB 75 mA I 195 mA Expansion Signal Module and Options (1.5 A Class B except as noted) M6del Dntióii Siji Alarm 4100-5116 Converts 1 NAC in to 3 NACs out; 1 Block size 18 mA 80 mA 1 4100-5015 1 Class 75 mA 1 195 mA 4100-1266 Expands 3 NACs to 6 select one; mounts 4100-5116 0.6 mA 60 mA * IDC Modules are 1 Slot size 4100-1267 Converts 3 NACs to Class Alon 0.6 mA 30 mA Continued on next page S4100-0031-20 9/2012 Module Selection Information (Continued) Miscellaneous Accessories BescripiLion 4100-1279 Single blank 2" display cover; 4100-2302 provides a single plate for a full bay 41009856* 4100E5 Canadian French Appliqué Kit; Simplex, 4100ES, Controle Incendie 41009857* 4100ES English Appliqué Kit; Simplex, 4100ES, Fire Control 41009858* 4100ES InfoAlarm Remote Display English Appliqué Kit; Simplex, Operator Interface, 4I00ES 41009859* 4100ES InfoAlarm Remote Display Canadian French Appliqué Kit; Simplex, Interface de l'operateur, 4100ES 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-6029 Smoke Management Application Guide; required for UUKL listing 4100-6034 Tamper Switch, one per cabinet assembly if required; monitors solid door for panels with solid door; monitors the internal retainer panel for panels with glass door (not the glass door); has a built-in addressable IDNet lAM 2081 -9031 Series resistor for WSO, lDCs (N.O. water flow and tamper on same circuit, wires after water flow and before tamper) 470 0, 1 W, encapsulated, two 18 AWG leads (0.82 mm2 ), 2-1/2" Lx 1-3/8" W x 1" H (64 mm x 35 mm x 25 mm) * Note: 4100ES English Appliqués are included with 4100ES Upgrade and Retrofit Kits for mounting 4100ES in 4100, 2120, 2001, and Autocall back boxes so that upgrades can be easily identified as 4100ES. 4I00ES Appliqué Kits are available for applications such as to update Remote InfoAlarm Displays connected to a panel that was upgraded to 4100E5 or for an existing 4100U when the New Master Controller is upgraded to 4100ES and only a software upgrade is required. When required, French appliqués are ordered separately. Addressable Interface Modules (refer to location reference on pages 8 and 9) a Model 4100-3101 Description - IDNet Module, 250 point capacity With 250 IDNet devices, add Supv. 200 mA Alarm I 250 mA 4100-3104 IDNet Module, 127 point capacity With 127 IDNet devices, add 102 mA 127 mA 4100-3105 IDNet Module, 64 point capacity . With 64 IDNet devices, add 51 mA 64 mA IDNet Modules, Specifications for each capacity; Module without devices 75 mA 115 mA 0.8 mA I mA Module size = 1 Block Loading per IDNet device Model Description Supv. Alarm MAPNET II Module, 127 point capacity, add devices Module without devices 255 mA 275 mA 4100-3102 separately; Module size = 2 Slots; 471 mA 491 mA Loading per MAPNET II device = 1.7 mA Fully loaded module, total Isolator Module for MAPNET II or IDNet; converts a single connected SLC into four isolated outputs selectable as Class A or Class B; up to two Isolator Modules can be 4100-3103 connected to one SLC; Module size = I Slot; 50 mA 50 mA NOTE: Compatible with MAPNET II Remote Isolators only; for quad isolation with IDNet Remote Isolators, use 4100-3107 lDNet+ Module (see data sheet S4100-0046 for details) Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on pages 8 and 9) 1 Mod& 4100-3202 Description 4 DPDT w/feedback Resistive Ratings 10 A 250 VAC InductiveRatrngs 10 A 250 VAC Se 2 Slots SUpV 15 mA Alarm 175 mA 4100-3204 4 DPDTw/feedback 2A 30VDCIVAC 1/2A 30VDC/120VAC 1 Block 15 mA 60 mA 4100-3206 8SPDT 3A 30VDC/120VAC 1-1/2 A 1 30 VDC/120 VAC 1 Block 15 mA 190 mA Current Calculation Notes: To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered by panel power supplies. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all external loads powered from panel power supplies. S4100-0031-20 9/2012 General Specifications System Power Supplies (SPS) 120 VAC Models I 4 A maximum @ 102 to 132 VAC, 60 Hz Input Expansion Power Supplies (XPS) I Power Remote Power Supplies (RPS) 220-240 VAC I 2 A maximum @ 204 to 264 VAC, 50/60 Hz; TrueAlert Power Supplies (TPS) Models separate taps for 220/230/240 VAC Power Supply Output Total Power Supply Including module currents and auxiliary power outputs; Output switches Ratings for SPS, XPS, Output Rating "Special 9 A total for Application" appliances; 4 A total for to battery backup and RPS "Regulated 24 DC" power (see below for details) during mains AC 2 A maximum I (nominal 28 VDC on Auxiliary Power Tap failure or AC; 24 VDCon battery backup) NACs Programmed Rated 19.1 to 31.1 VDC brownout conditions 2 A maximum per NAC; for Auxiliary Power 5 A maximum total Special Application Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, and combination horn/strobes and speaker/strobes Appliances I (contact your Simplex product representative for compatible appliances) Regulated 24 DC Appliances Power for other UL listed appliances; use associated external synchronization modules where required Battery Charger Battery capacity range UL listed for battery charging of6.2Ah up to 110 A (110Ah batteries require a Ratings for sps, remote battery cabinet); ULC listed for charging up to 50 Ah batteries RPS and TPS (sealed Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 lead-acid batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Environmental Operating Temperature 32" to 120°F (0° to 49° C) Operating Humidity Up to 93% RH, non-condensing @ 90° F (32" C) maximum Additional Technical Installation Instructions 574-848 Reference Operating Instructions 579-197 Mounting and CPU Bay Module Reference (* indicates supplied modules) Slot 3, one 2" card: either 4100-6078 Network Module with media cards or 4100-6038 Dual RS-232 - Master Con 4100-6030 Service Modem mounts troller Bay only on master controller board Two, 2", or one, 4" slot for one or two modules installed - 4100-6031 or 4100-6032 per the following: City Circuit or 4100-6033 4100-6052 DACT, Slot I Sill oti El Alarm Relay S11 i2 4100-6101 Physical Bridge, 5013 Slot 4100-6102 Physical Bridge (4" module) Slots I and 2 "Master controller "System power supplJ Exposed cabinet for 4100-6048 VESDA Interface, with motherboard , , semi-flush mounting Slot I 0r2 4100-5005/5015 IDC Modules, Slot lor2 4100-6038 Dual RS-232, Slot 2, if Network Module is in Slot 3 I Typical Expansion Bay Compartmentfl . 1-3/8" (35 mm) minimum Exposed door and cabinet for semi- (showing mixed module sizes)j flush mounting 6-1/8'(156 mm) Two bay cabinetL_—' minimum shown without retainer[' HkH 1' Knockout Cabinet height screw/nail (2 bay shown holes (for for reference) semi-flush mounting) 1Bay = 22 (559 mm) 2 Bay = 40" (1016 mm) 3 Bay = 56" (1427 mm) Wall board reference for semi-flush mounting, 6" stud Stud alignment markers, each side Door thickness 4-314(121 mm) Door ra' —'ZIIIl Door 4-3/4" [edleftoij 24(61omm)________J (121mm)1 (175 mm) Optional semi-flush trim kit] 1111/16"_____ NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. 8 S4100-0031-20 9/2012 Expansion Bay Module Loading Reference Slot Slot Slot Slot Slot Slot Slot Slot Block Block Block Block Block B Block D Block F Block H Bay Chassis Size Definitions: Block = 4" W 5" H (1102 mm x 127 mm) card area Slot = 2" W 8" H (51 mm x 203 mm) motherboard with daughter card Description Mounting IDNet Modules 1 Block 4, 2 A Relays NON Power-limited 1 block 4, 10 A Relays 4", 2 slots 8, 3 A Relays 1 block VESDA Interface 2", 1 Slot Class B IDC 2", 1 Slot Class A IDC 2", 1 Slot MAPNET II Module 4", 2 Slots MAPNET Il/IDNet Isolator 2", 1 Slot Class B Physical Bridge 2", 1 Slot Class X Physical Bridge 4", 2 Slots Decoder Module 6", 3 Slots System, Remote, or TrueAlert Power Supply Blocks E, F, G & H ONLY Expansion Power Supply Blocks G & H ONLY NAC Expansion Module On XPS ONLY Additional 4I00ES Data Sheet Reference [Subject Introducing the 4I00ES S4100-0060 bs --bata sior Agent Release Applications Sheet S4100-0040 4100ES Enclosures S4100-0037 Fire Alarm Network Overview S4100-0055 4100ES Audio and Firefighter Phone Modules S4100-0034 Network Communications S4100-0056 LED/Switch Modules & Printer S4100-0032 Network Display Unit (NDU) S4100-0036 Remote Annunciators S4100-0038 Addressable Device Compatibility S4090-0011 MINIPLEX Transponders S4100-0035 TrueAlert Addressable Products S4009-0003 Building Network Interface (BNIC) S4100-0061 lDNet+ Module w/Quad Isolator S4100-0046 InfoAlarm Command Center S4100-0045 Remote Battery Charger S4081-0002 Graphic I/O Modules S4100-0005 TFX Interface Module S4100-0042 SafeLINC Internet Interface S4100-0028 Master Clock Interface S4100-0033 Truelnsight Remote Service S4100-0063 2120 BMUX Module 54100-0048 S4100-0031-20 9/2012 TYCO, SIMPLEX, and the product names listed in this material are mar/is and/or registered marks. Unauthorized use is strictly prohibited. Microsoft and Windows are trademarks of Microsoft Corporation. VESDA is a trademark ofXtralis Pry Ltd. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). ASHRAE and BACnet are trademarks ofASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers. SiFri I E Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4100-0031-20 9/2012 www.simplexgrinnell.com 0 2012 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0251 Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4100-9111, -9112, -9113, -9114, -9115, -9116, -9121, -9122, -9131, -9132, -9133, -9211, -9212, -9213, -9222, -9230, -9311, -9312, -9313, -9314, -9315, -9316, -9331, -9332, -9511, -9512, -9513, -9600, -9601 and -9602 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station, proprietary and central station, process monitoring, smoke control system, smoke detector monitor, emergency communication and relocation, waterfiow and sprinkler supervisory service. Suitable for releasing device service. Models 4100-9111,-9112,-9113,-9114,9115,-9116,-9121,-9122,-9211,-9212,-9213, -9222, -9311, -9312, -9313, -9314, -9511, -9512 and -9513 suitable for mass notification system as an autonomous control unit. The network display units are suitable for mass notification system system as a central control station. *The remote annunciators are suitable for mass noticication system system as a local operating console. Refer to listee's data sheet for detailed product description and operational considerations. System components: 4100-7101, -7104, -7113, -7115: Master Controller Assembly 4100-7105: Redundant Master Controller Assembly 4100-7150, -7151, -7152-7154-7156, -9833: Master Controller Replacements 4100-5005, -5015: 8-Point Class A IDC Module 4100-1291: Remote Unit Interface Module 4100-3102, -9812: MAPNETII Module 4100-3103: MAPNET/IDNET Isolator Module 4100-6038 RS-23212120: Communication Module 4100-6014-6078: Modular Network Interface Module 4100-1293: Printer 41006052,*6080: Event Reporting DACT 4100-6053: Point reporting DACT 4100-6067: Contact Closure DACT 4100-6031, -6032, -9827, -9828: City Module 4100-2300,-2320: Expansion Bay 2975-9408 thru -9412: Backbox 2975-9438 thru -9440: Backbox 4100-2101 thru -2103, -2121 thru -2123: Glass Door and Retainer 4100-2104 thru -2106, -2124 thru -2126: Glass Door and Retainer *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 2 of 4 4100-2111 thru -2113, -2131 thru -2133: Solid Door 4100-2114 thru -2116, -2134 thru -2136: Solid Door 2975-9422 thru -9426, -9428, -9429: Enclosure 2975-9431, -9432: Enclosure 2975-9441 thru -9452: Enclosure 4100-0633, -6034: Tamper switch 4100-9141-9142-9151-9152-9241 thru -9246,-9342,-9352,-9542 Network Display Unit 4100-6030, -6055: Service Modem 4100-5101, -5102, -5103: Expansion Power Supply 4100-5111, -5112, -5113: System Power Supply 4100-5125, -5126, -5127: Remote Power Supply 4100-1288, -1289: LED/Switch Controller 4100-1275 thru -1287, -1295, -1299: LED/Switch Module 4100-1300, -1301, -1302: LED/Switch Module 4100-1290 24: Point Graphic I/O Module 4100-9607,-9609,-9610,-9611,-9612,-9614,-9615 Remote Annunciator 4100-1292: Remote LCD Display 4100-3115: XA Loop Interface Module 4100-3101,-3104,-3105,-3106,-3107,-3108,-9811 IDNET Module 4100-9116: Addressable IDNET Isolator 4090-9117: Addressable Power Isolator 4100-9643: Utility Cabinet 4100-0634, -0635: Power Distribution Module 4100-5152, -5153, -5154, 5155: Auxiliary Power Supply 4100-6033, -9829: Alarm Relay Card 4100-3201, -3202-3203-3204-3206: Auxiliary Relay Modules 4100-0620: Basic Transponder Interface Card 4100-6043, -6044: Converter 4100-6045: Decoder Module 4100-6054: Fiber Optic Driver 4100-5115: Expansion NAC 4100-9816: Master Clock Interface 4100-6048: VESDA Interface 4100-5311-5313-5325-5327: Extended Power Supply 4100-6103: Dual Class Isolator 4100-5120, -5121, -5122: True Alert Power Supply 4081-9306, -9308: Expansion Battery Charger 4100-2140: Rack Mount Bay Mounting Kit 4100-2144: Rack Mount PDM Mounting Kit 4100-0156: Eight Volt Converter 4100-0625: Local Mode Transponder Interface Card 4601-9100, -9108-9109-9110-9111 Local Mode Controller 4100-0623: Basic Network Transponder Interface Card 4100-0621, -0622, -1341 :Audio Riser Module 4100-6036, -6037-6101-6102: Physical Bridge Assembly *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 3 of 4 4100-9849, -9863: TCP/IP Physical Bridge Assembly (Style 4) 4100-9850, -9864: TCP/IP Physical Bridge Assembly (Style 7) 4100-6056: Wired Media Card 4100-6057: Fiber Optic Media Card 4100-9620: Analog Audio Expansion Bay 4100-9621: Digital Audio Expansion Bay 4100-1210: Analog Audio Controller Card 4100-1211, -1311 : Digital Audio Controller Card 4100-1212 thru -1225, 1261, -1262 Analog Audio Amplifier 4100-1312 thru -1325, -1361, -1362 Analog Audio Amplifier 4100-1226 thru -1239, 1263, -1264 Digital Audio Amplifier 4100-1326thru -1339, -1363, -1364 Digital Audio Amplifier 4100-1240: Audio Input Option Card 4100-1241, -1242: Message Expansion Card 4100-1243, -1244: Microphone Module 4100-1245, -1248, -1266: Amplifier Expansion NAC 4100-1246, -1249, -1267: Amplifier Class A Adapter 4100-1252, thru -1255 :Audio Operator Interface Module 4100-1270: Master Telephone Assembly 4100-1271 : Remote Telephone 4100-1272: Expansion Phone Card 4100-1273: Telephone Class A Adapter 4100-5116: Expansion Signal Card 4100-1259, -1260, -1268: Constant Supervision NAC Modules 4100-1265: Degrade Fail-Safe Microphone Module 4100-6068: TFX Interface Module 4100-6072, 6073, 6074, 6075: Fiber Optic Modem 4100-9842: Fiber Modem Audio Expansion Board 4100-9901 thru -9926, -9930 thru -9939Retro-fit Kits 4100-7153, -7155: Display Replacement 4100-9401,-9402,-9441,-9442: Remote User Interface 4100-0640: FUI Controller Memory Add-on Module 4100-7157 : Expanded Memory CPU Card 4100-6065: BMUX Communication Card 2081-9046: Coil Supervision Module 4100-6066: TFX Loop Card 4100-5130: TFX Voltage Regulator Module 4100-1340: TFX Audio Interface Module 4100-1297 : TFX Phone Card 4100-1298: TFX Master Telephone with Phone Card 4100-6069: BACpac Ethernet Module 4100-1274: Microphone Multiplex Module 4100-6047: Building Network Interface Card 4190-6104: Remote Service Gateway RATING: 120, 220, 240 VAC primary; 24 VDC secondary *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 4 of 4 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model/catalog number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units suitable for use with separately listed compatible initiating and indicating devices. Also Suitable for high-rise applications. The control unit is compatible with the Model 4090-9007Signal Individual Addressable Module (CSFM Listing No. 7165-0026:318). These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification feature (delay of the fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined from 7170-0026:250 *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division !iSim plEx LifeAlarm® Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control from 4010, 401OES, MEA (NYC) Acceptance* 4I00ES/4100U IDNet Communications, or Conventional NACs I1t!i(*I Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Four, Class B NACs are standard: Rated 2 A each for conventional reverse polarity 24 VDC notification appliances and providing multiple operation modes Can be selected to provide synchronization for Simplex® visible notification strobe flashes Capable of controlling TrueAlert® non-addressable notification appliances operating with SmartSyncTM two-wire control mode** Input control options: IDNet addressable communications from a Simplex model 4010, 4010ES, 4100U, or 4100ES Fire Alarm Control Panel** Or from one or two conventional 24 VDC NACs with multiple output control options IDNet communications control benefits: Provides status monitoring and individual NAC control using a single address per 4009 IDNet NAC Extender Supports IDNet "Device Level" earth fault location WALKTESTTM operation is available with either input choice Internal 8 A power supply/battery charger: Charges internal batteries up to 12.7 Ali or up to 18 Ali batteries in external cabinet Provides status monitoring of battery, input power, and earth faults Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, horn/strobes, and speaker/strobes Rated 6 A for "Regulated 24 DC" appliance power Optional 4009 IDNet NAC Extender modules: IDNet Communications Repeater provides Class B or Class A output IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class X Four additional Class B NACs, rated 1.5 A for Special Application appliances; 1 A for Regulated 24 DC appliance power Class A, Two Circuit Adapter Module UL Listed to Standard 864 I ii I!r1V*is]l-1 IDNet communication fiber optic transmitters: For applications requiring the data integrity available with fiber optic communications Available as Class B or Class X Mounts in standard six-gang electrical box External battery cabinet for 18 Ah batteries NAC Control 4010 (shown) or LII'S 4010ES/4100ES/4100U Alarm Control Panel Fire Alarm Control Panel with Conventional NACs 4009 IDNet NAC Extender Connection Reference Drawing rnrrrrrnT1 ADA Compliance. Complying with the notification requirements of ADA (Americans with Disabilities Act) may require more notification appliance power than is available within the fire alarm control panel. When additional power is required, a Simplex 4009 IDNet NAC Extender can provide up to 8 A of NAC power with up to eight, supervised reverse polarity NACs. Location Flexibility. The 4009 IDNet NAC Extender can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power distribution. Multiple operation modes and multiple connection options further increase location flexibility. Additional Information. For additional operation detail and application information, refer to Installation Instructions 574-181 and field wiring diagram 842-068. * ULC listed model is 4009-9202CA. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:214 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of SimplexGdnnell LP, Westminster. 41001.1 requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. S4009-0002-9 2-Wire I Communi L.UIIIIIIUIIItdUWIIb 'I —. IDNet Fiber Optic Transmitter IDNet Addressable Communications Compatible. Up to ten (10), 4009 IDNet NAC Extenders can be controlled per 401OES/4 100ESI4100U IDNet communications channel; up to five (5) can be controlled on the 4010 IDNet communications channel. Each output NAC can be individually controlled for general alarm or selective area notification requiring only one point address per Extender. Individual Extender NACs can also be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles via IDNet communications. 401OES/4 100ES/4 100U control panels control using multi-point rules, refer to data sheet S4090-0011 for details. Optional IDNet Repeaters. IDNet communications can be repeated with the optional IDNet Repeater Module or with the optional Fiber Optic Receiver Module. Up to 100 of the IDNet channel points can be repeated once (refer to pages 3 and 5 for details). Repeated IDNet communications also support the "device level" earth fault location utility of * the host panel. Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs additional power, the 4009 IDNet NAC Extender can be controlled directly from the NAC. Either one or two NACs, from either the same, or from different host fire alarm control panels, can be connected to control the 4009 IDNet NAC Extender output NACs. Multiple control selections provide flexible operation. (Refer to page 4 for more detail.) Alarms from the host panel will activate the four, 4009 IDNet NAC Extender NACs (or optionally, eight NACs) to extend the alarm. The 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions, including earth faults. Extenders wired to conventional NACs will indicate a trouble by opening the path to the NAC's end-of-line resistor, but retaining the ability to respond to alarms. Individual troubles are also annunciated by LEDs located on the 4009 IDNet NAC Extender main circuit board. (Refer to page 7 for more diagnostic information.) \ Standard Models Model . Deriii I 120 VAC 40099202CA* I input I 4009 IDNet NAC Extender with 4, Class B NACs and 8 A power supply 4009-9301 240 VAC input * (JLC listed model Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009-9807 Application appliances; I A for Regulated 24 DC appliance One maximum power, Class B 4009-9808 Dual Class A adapter (for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A or Class B Select either an IDNet Repeater or a Fiber Optic Receiver as required 4009-9810 Fiber Optic Receiver Class B 4009-9811 Class A (IDNet), Class X (fiber) 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit Beige trim 1-7/16" wide (78 mm), use if required for semi-flush installations 2975-9802 Red trim Battery Selection (select battery size per system requirements) Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC External Accessories (select per system requirements) IComments Two batteries are required, 24 VDC operation Requires external battery cabinet, two batteries are required, 24 VDC operati - Description - Comrnents 4090-9105 IDNet Fiber Optic Class B operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class X operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series J End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details 2 S4009-0002-9 Ce 4100ES (shown) or 4100U/4010ES/4010 Fire Alarm Control Panel 4090-9105, Class B Output Fiber Optic Transmitter Iwofiber cable nnn ft (914 m) maximun 4010, 4010E5, 4100U or 4100ES Fire Alarm Control Panel 24 VDC power for fiber optic transmitters 4090-9107, Class X (Style 7) Output Fiber Optic Transmitter 4009 IDNet NAC Extender! internal IDNet Fiber Receivers EurSiber cables 3000 ft (914 m) maximum disb Typical IDNet Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements some wiring is not shown) " IDNet addressable communications chann?l Class B Output NAC four standard Conventional NAC operatior(homs) eight with expansion option Select conventional L..J or SmartSync operation per NAC Tip"" SmartSync operation(horns and strobe 4009 IDNet NAC Extender with Ea l MMIMMiMM.0 - Conventional NAC optional internal IDNet Repeater operation (strobes) RepeatediQi Channet - up to 100 devices maximum on repeater output 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to ten (10) 4009 IDNet NAC Extenders maybe connected per 4010ES, 4100ES or 4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System connections IDNet addressable communications channel Class Bor Class A Class B shown Repeated.[QNet Channel: up to 100 devices maximum on repeater output 250 devices total on IDNet Channel NOTE: Up to ten (10) 4009 IDNet NAG Extenders maybe connected per 4010ES, 4100ES or4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009-0002-9 NAC Input Selections. The 4009 IDNet NAC Extender can be selected to: Track input NAC operation or to provide a locally generated code, selectable per NAC input If selected for local coding, NAC outputs can be either Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender (input NACs must be on continuous with Alarm) Additionally, NAC outputs can be selected to provide the Simplex strobe synchronization signal. This signal will synchronize the flashes of synchronized strobes but will be ignored by free-run strobes and audible devices. (Strobes are for operation by noncoded NACs.) NAC input to NAC output control can be selected for standard and optional NACs per the following table: Conventional NAC Output Operation Options Input .1 1 .AY: B. NAC1 NACs 1&2,5&6 NACs 1-4 NACs 1-8 NAC 2 NACs 3 & 4, 7 & 8 NACs 5-8 None SmartSync NAC Output Operation Input NAC Control Function NAC 1 Strobe Control All NAC outputs (1-8) NAC 2 Horn Control ISmartSvnr Notification Arrnliance Control The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAC Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification 4009 IDNet NAC Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs IDNet control allows output NACs to be individually selected for conventional or SmartSync operation With NAC input control, all output NACs are selected for either conventional or SmartSync operation Refer to data sheet S4009-0003 for TrueAlert Addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances Hardwire Control NAC Connection One-Line Reference Diagram Up to eight (8) output NACs total; hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input (see Note 1) Conventional NACs ____ ____ With hardwire control I NAC outputs are all Output conventional or all NACs - SmartSync operation 4009 IDNet NAC I - /I Extender • / I Fire Alarm Control Panel with Conventional NACs / ----------------------- Class operation — / Class A operation, either mode, requires NAC 2 input 4009-9808 Dual Class A Adapter (optional, see Note 1) To additional 4009 IDNet NAC Extenders (up to four (4), -----------] 4009 IDNet NAC Extenders per NAC); see Note 2 Notes: For separate audible and visible output NAC control, or SmartSync NAC output operation, two (2) input NACs are required. NAC 1 is "on-until-reset" and NAC 2 is "on-until-silenced." To synchronize strobe flash outputs for up to four (4) 4009 IDNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 for Class B operation, 4905-9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 1 S4009-0002-9 [['Islil m] ri r.x.iI IM: 120 VAC Input (4009-9201) 3A@ 102-132 VAC, 60 Hz Input Ratings 240 VAC Input (4009-9301) Hardwire Control from External NACs, Input Requirements 1.5A © 204-264 VAC, 50/60 Hz Conventional reverse polarity operation 5 mA maximum; 16 to 33 VDC Total Rating8 A, Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs Optional NACs (requires 4009-9807) 2 A each, Special Application or Regulated 24 DC appliance power 1.5 A each, Special Application appliances 1 A each, Regulated 24 DC appliance power Output Ratings Special Application Appliances PP Simplex 4901, 4903, 4904, and 4906 Series non-addressable horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product representative for compatible appliances) Regulated 24 DC Appliances Power for other UL listed appliances; use associated external synchronization modules where required on Strobe Operation b . Auxiliary Output Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA © 24 VDC, system supplied IDNet Repeater Module (4009-9809) IDNet Input, One Address IDNet Output Specifications Maximum distance from IDNet source is 2500 ft (762 m) Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed 250 per channel) Maximum distance to farthest device is 2500 ft (762 m) Total distance including "T-taps" is 10,000 ft (3048 m) Class Aloop maximum distance is 2500 ft (762 m), no "T" taps Fiber Optic Receiver Modules Input Current 4009-9810, Class B, 65 mA 24 VDC, system supplied 4009-9811, Class X, 80 mA© 24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 90% RH from 32° F to 104° F (0° C to 40° C) Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Fiber Optic Transmitter Specifications Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B, 30 mA @ 24 VDC 4090-9107, Class X, 35mA@24VDC Fiber Optic Connections and cable requirements Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors 4090-9105, Class B operation, two fiber cables required 4090-9107, Class X operation, four fiber cables required Module Size (with mounting bracket) 6-13/16" W x 3-3/4" H x 1-1/8" D (173 mm x 95 mm x 29 mm) On-board Status Indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft (914 m) maximum Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity 10% to 90% RH from 32° to 104° F (0° to 40° C) Operating Temperature 32° F to 120° F (0° to 49° C) * Metric wire equivalents: 18 AWG = 0.82 mm2; 12 AWG = 3.31 mm2 5 S4009-0002-9 4009 IDNet NAC Extender Mounting and Module Placement Information © 16-1/4 (413 (4.) 10-29/32" (277 mm) - 0 Man 0 ::::: LLI - ( Optional Class A " (4009-9807 Additional Four'( (. adapter modules J I point module (shown with © Class A adapters) C System Module 0 0 I1 (Fib DNet repeater or") er optic receiverJ ll © 0 12(305mm) Battery location, no conduit entry or wiring in -i this area (12.7 Ah battery outline shown) 01 Non-power limited wiring area (AC input) L... Cabinet depth 4-1/4" (108 mm)-,•J Door, 5/8" (16 mm) thick 13-1/2" (343 mm) Exposed cabinet dimension for semi-flush mount 1" (25.4 mm), 1-3/8" (35 mm) with semi-flush trim Knockouts for screw or nail mounting holes 7L Semi-flush trim option 1-3/16" wide (30 mm), 3/8" (9.5 mm) thick Wall surface reference for semi-flush mount NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 lDNet NAC Extender Cabinet with Door Detail Optional red appliqué (4009-9805) 6 S4009-0002-9 II • I-I I vII !,.:1 II. •. _• )JII \..• - 0 0 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: Simplex model 2975-9217 (ordered separately) —€—ppAII Flush mount masonry box: use 6-gang box, RACO # 960, 2-1/2" deep (64 mm), or RACO #965, 3-1/2" (89 mm) deep, or equal (supplied by others) Flush mount ganged boxes: use 6-gang box, 1-1/2" (38 mm) minimum depth; six, RACO #400 or equal, (supplied by others) o o 0 0 0 0 o o 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class X (Style 7) output 4090-9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) l(*I Power-up Self-Diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The 4009 IDNet NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit - During an alarm, the LED follows the NAC output (on steady or flashing with coded output) Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. 7 1 S4009-0002-9 4009 IDNet NAC Extender Current Chart Panel Module Selection (shaded model numbers are optional modules) Model Description supervisory Cuirent Supevisory Alarm Current Actual Alarm c4009:9201) (IVAC input Basic Panel (85ThA 85 mA - (185 mA 185 mA 4009-9301 240 VAC input _____________ _____________ _____________ 4009-9807 Additional Four Point NAC 40 mA + NAC loads + NAC loads +(add below) (add below) 4009-9808 Dual Class A Adapter (current - - - included in basic panel value) 40097 809* IDNet Repeater 70 mA + 70 mA + 80 mA 4009 98lO' Fiber Optic Receiver Class B 65 mA 65 mA 4009--§ V Fiber Optic Receiver Class X 80 mA IDNet Devices, 0.7 mA each, maximum of 100 Total devices + Total devices Al + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output, calculate per total 500 mA + 500 mA 'A2" + device requirements (see note 5) maximum maximum Total Supervisory Current (11211) Total 4009 IDNet NAC Extender Panel Alarm Current * Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads NAC Type NAC Circuit #. NAC Alarm Current Circuit 1 + Circuit + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit + Circuit 4 + Circuit 5 + Circuit 6 + Optional Four Point NAC Module, 1.5 A maximum per NAC (see note 5) Circuit + Circuit 8 + Total NAC Loads Alarm Current = -(C) Total 4009 IDNet NAC Extender Panel Alarm Current (enter Bi from above) = (62) + (D) Procedure: Total Alarm Current = Calculate total panel supervisory current (A). Calculate total panel alarm current (131) [convert mA to A, example: 350 mA = 0.35 A]. Copy (131) into block (132). Calculate total NAC loads alarm current from notification appliance ratings (C). Add (C) + (132) to determine total alarm current (D). Total of IDNet Device Current (Al) + Auxiliary Power Output Current (A2) + NAC Loads Alarm Current (C) is 8 A maximum. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements (i.e. 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, the Simplex logo, LifeAlarm, IDNet, WALKTEST, SmariSync, and TrueAlert are trademarks of Tyco International Ltd and its affiliates and are used under license. ini p1 EX SimplexGrinnell LP Westminster• Westminster, MA 01441-0001 USA www.simplexgrinnell.com 02011 Tyco. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0214 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmaftern@tycoint.com DESIGN: Models* 4009-9001, 4009-9002, 4009-9101, 4009-9102, 4009-9201, 4009-9301, 4009-9401 Notification Appliance Circuit (NAC) Power Extenders. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 40909105,*9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803-98044 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module *4003..9803 Remote Microphone Module RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 - minutes of alarm as required by code. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. NOTE: *Rev/Rece 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 3®SimpIex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM and MAPNET It® Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (lAMs) IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplexth 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use with following Simplex control panels: Model Series 4008, 4010, and 4100U fire alarm control panels for IDNet communications Model Series 4100/4100U, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: . Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 SlNp[[' s? 4090-00, D W AN . 169. 511-Sti SATE CODE 4090-9001 Supervised lAM (shown approximately 3/4 size) 4090-9051 Supervised [AM (shown approximately 3/4 size) srintir Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. * These products have been approved by the California State Elm Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for -- IDNet and MAPNET II addressable communications are protected under U.S. Patent use - City of New York Department of Buildings - MEA35-93E. Additional listings may be Nos. 4796,025; 5,966,002; and 6034601. applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0001-8 2/2006 Dnratir Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). liratin-fs For use with IDNet communications only, these JAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. uu Model Description (4090-9001) Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kcl, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 k9), 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 kn, 1/2W Specifications Electrical Power and Communications MAPNET II orç et)auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections 0 9001 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 It (152 m) maximum without protectors 400 It (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or I 2500 It (762 m) maximum from fire alarm control panel IDNet Communications 110,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W x 1-3/4" H xl-1/4"D(40mmx44mmx32mm) 1-9/16" W 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-8 2/2006 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference i 1H sopula in IIi. IKI. s•s DAIC co '1 LED viewing port Single gang electrical box 2-1/2' (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting,screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate - _________ © Light pipe for LED viewing [ 1 ( I (108 mm) 114 mm) LOIScONNEOT POWER 1 BEFORE SERVICING j BEFORE SERVICING j [ J © © CD IF 2-1/2" 2-13/16" (64 mm)_______ (72 mm) 4090-9806, Trim plate for 4090-9807, Trim plate for 4090-9810 Mounting bracket, ordered semi-flush mounted box surface mounted box separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-8 2/2006 1 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Encapsulated Supervised lAM Single gang electrical box 2-1/2 (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) Tyco, Simplex, the Simplex logo, MAPNETJJ, and IDNet are trademarks of Tyco International Services AG or its affiliates in the US. and/or other countries. ®SinipIex Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S4090-0001-8 2/2006 www.tycosafetyproducts-usa-wm.com 0 2006 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 2; FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -90021TP lAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: *Rec 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Duct Sensor Housing, Front and Bottom View & 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station dtictir, Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. £LSimpIEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I1(!I(*I Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet,'MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interlace board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document, It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional lisifngs may be applicable; contact your local Simplex product supplier for the latest status. Ustings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4098-0030-9 11/2012 IMUM, F.M.W-Mmino gnrnnwt.romymmr7jaJ Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) I TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. I !Ti1f we (71Ii117!JIj Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control Duct re1ection Chart F, or override Duct Smoke Sensor Housing with Photoelectric Sensor* Dscriphon Basic Duct Sensor Housing; operating power is supplied by 4098-9755 either lDNet or MAPNET II communications (no relay output) C rnptibty Simplex fire alarm control panel models: 4100ES, 401OES, 4008, 4010, 4100U, and legacy products 4020, 4100/4100+, and 4120. Also 2120 CDT if configured for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays I (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description compatibility 2098-9808 Red LED status indicator on single-gang stainless steel plate Test Station with keyswitch and red LED status indicator, on 09-980 single-gang stainless steel plate; (turning switch to "TEST" initiates alarm for system testing) \ Epoxy Encapsulated Remote Relay and End-of-Line Resistor \ Model Descnption Compatibility Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; t4p98-9843) for additional relay information; one included with 4098-9756; connect u to wiring is 18 AWG (0.82 mm2 ) color coded wire leads p 15 4098-9755 4098-9756 Mounting Use single gang box, 3" Hx2"Wx2" D (76 mm x 51 mm x 51 mm) Location Locate relays within 3 ft (1 m) of device being controlled per NFPA 72 - 4081-9008 I End-of-Line Resistor Harness; 10 kn, 1/2W; (ref. 733-894); required to supervise remote relay coil connection 4098-9756 At last relay location I * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. OveraflDuctWidth (305 mm) Tube Required 4098-9854 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 4098-9858 3 in" (76 mm) longer than duct width S4098-0030-9 11/2012 i: .LMetal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole rtT000aal© II, •TTI'M DS00 !I I1 ton oo Yellow LED, relay control trouble indicator (4098-9756 only) Red sensorON l status LEDJ 4098-9714 Smoke sensor, mounted in special interface base (supplied) (171 mm) access hole 'S 0[Exhaust tube K---7 ------------ DO NOT MOUNT ON BOTTOM OF DUCT /\ 'it.i : nriirni I NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. (289 mm). wst tube access affle (built-in))' (Captive fastening screws IGasIceted sensor area I NOTE: Orientation shown is for reference only, refer to General Location Notes and End View illustration below for alternate mounting reference. (21 mm) 13/16 Exhaust u lied) 1' Test ports (2) provided SamPlin tube, ordered for measuring airflow and for aerosol injection separately per duct width reference outline Alternate location (ji appropriate 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1-3/16" (30 mm) 1-1/2" 13/16" (38 mm) (21 mm) 18' Round duct outline (minimum diameter) Sampli~tue,~edoper hole~gnen with holes facing into air ovided for be installation).0 (Housin on 2 per n w.) General Location Notes: Testing performed under the auspices of the Fire Detection Institute (FDI) recommended when sampling tubes are not located vertically, that they be positioned horizontally in the upper half of the duct to account for possible stratification. Three duct side mounting options are available as shown below. Mount housing at 90° to airflow for all orientations. Arrows indicate allowed airflow directions. 15 3 S4098-0030-9 11/2012 Duct Sensor Location Reference Exhaust Damper r(_ Sensor OK Exhaust II -.--Return Air Do not locate sensor here Return air damper Fresh air— [j - Supply Air Do not locate Filter bank Sensor OK sensor here Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NEMA Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-776. Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. Duct air velocity rating is 300 to 4000 ft/mm (91 to 1220 rn/mm). Pressure differential between intake and exhaust tubes is required to be between 0.0 15 to 1.55 inches of water (0.381 to 39.37 mm). Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Specifications General Mechanical and Environmental Air Velocity Range (linear ftimin) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current (3 mA @ 24 VDC) Alarm Current (15 mA©24VDC;)add 15 mA for each 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 ko, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current (15 mA @24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC & 120 VAC; 250 iA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device being controlled per NFPA 72 TYCO, SIMPLEX, and the product names listed in this material are marks and1or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S i rn p I EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4098-0030-9 11/2012 02012 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 6 1-1 LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmatterntycoint.com DESIGN: Models 4098-9755, *4098..9755Tsp *40989755up 4098-9756, *4098..9756TSp *4098..9756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 -4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 ii This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 6- - : LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America Iric.25 Corporate Dr., Auburn Hills, Ml 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MR101/C/R *MR10sSE/C *MR101SsE/C/R MR-104/C, *MRi 04/C/R, -MR-104-SSE/C, *MR104SSE/C/R MR-201/C, MR201/C/*R, *MR.201..SSE/C *MR201ssE/C/R MR-204/C, MR204/C/*R, *MR204ssE/C *MR204S5E/C/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-1, RIC-2, RIC-3, RIC-4, MRRIC301/*C, *MRRIC301/C/R MRRIC305*/C, * MR-RIC-305/C/R, M RRIC401*/C, *MRR1C401/C/R MRRIC405*/C and *MR..RIC..405/C/R relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division B SimplEx TrueA!ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Speaker MEA (NYC) Acceptance* and Multi-Candela Strobe; Non-Addressable ra=m M_ Speaker/visible (SN) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash: Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important wall mount installation information on page 4) Wall mount SN features: Housings are available in red or white with clear lens with contrasting white or red "FIRE" lettering Covers are available separately to convert housing color Ceiling mount SN features: Housing is white with clear lens Red "FIRE" lettering is printed on two sides Audible notification appliance (speaker): High quality voice and tone reproduction with taps for ¼,V2, 1, or 2 W, at 25 or 70.7 VRMS Capacitor input for connection to supervised notification appliance circuits Speakers are wired separately from strobe wiring UL listed to Standard 1480 and ULCS541* Compliant with NFPA 72,520 Hz Low Frequency Signal Requirements for Sleeping Areas Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Strobes are activated from NACs selected to provide Simplex® strobe synchronization signals or from separate strobe Synchronization Modules that are available for Class B or Class A operation Regulated circuit design ensures consistent flash output and provides controlled inrush current UL listed to Standard 1971 and ULCS526* Options for wall mounted SNs: Red or white adapters to cover surface mounted electrical boxes Red adapter for mounting to Simplex 2975-9145 boxes Red wire guard * See page 2 for additional listing details and wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7320-0026:247 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product Supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall and Ceiling Mount SNs i1itT1I Multi-Candela TrueAlert SNs with speaker and synchronized strobe provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount S/V housings are a one-piece assembly (including lens) that mounts to a 4" square electrical box with extension (see details on page 4). The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount S/Vs also install using 4" electrical boxes with an extension (see details on page 4). During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. S4906-0003-8 5/2014 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Product Selection Wall Mount Multi-Candela SNs Model Housing "FIRE" Cor Lettering 4906-9151 Red White UL & ULC \\ 4906-9153 White Red Ceiling Mount Multi-Candela SN \\ Model Color, Lettering, Listings (4906-9154) White Red UL 4906-9157 I White I Red I ULC Multi-tapped Speaker with Multi-Candela 7 H 5W 2 % D Synchronized Strobe; strobe intensity (184 mm x 127 mm x 67 mm) selectable as: 15, 30, 75, or 110 candela Description Multi-tapped Speaker with Multi-Candela Synchronized Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela Dimensions Housing = 7 ¼" (191 mm) diameter, ¼" (13 mm) deep Strobe lens protrusion = 2 %" (67 mm) above speaker housing Depth into box = 2 %" (70 mm) Listings Description Housing Dimensions with Lens Wall Mount SN Adapters Mod& Dres criptic Dimensions 4905-9946 Surface mount red adapter skirt Required when mounting to surface 7 W H x 5 W W x 3 /l6" D mounted electrical box, 4" square, (197 mm x 137 mm x 81 mm) 4905-9947 Surface mount white adapter skirt 1 1/2' deep with 1 1/2' deep extension depth with SN = 5 Va" (149 mm) 4905-9903 Adapter Plate, red, required to mount SN on 2975-9145 86" Hx5WWx0.060" Thick 2975-9145 Mounting box, red, for surface or flush mount, requires adapter plate 7 %" H x 5 W W x 2 W D 4905-9903 (this box may be available for retrofit applications) (200 mm x 130 mm x 70 mm) Wall Mount SN Replacement Covers d&5crjption 4905-9996 Red SN cover with white 'FIRE" lettering 4905-9997 White SN cover with red "FIRE" lettering - -- :Dumensions 7 W H x 5" W x 1 W D (184 mm x 127 mm x 35 mm) Synchronized Flash Control Modules Model-Description. Dimensions 49059914* Synchronized Flash Module, Class B Epoxy encapsulated with in/out operation 18 AWG (0.82 mm2) wire leads, 1 /" W x 2 /16" Lx 13Aa" H 49059922* Synchronized Flash Module, Class A rated for 2 A NAC, requires 5 mA (35 mm x 62 mm x 20 mm) operation for power Wall Mount SN Wire Guard Model Descnption .'. Dimensions 4905-9998 Wire guard with mounting plate, red, compatible with surface and semi-flush 8 H x 6 /16" W x 3 1/a" D boxes (UL listed by Space Age Electronics Inc.) (213 mm x 154 mm x 79 mm) Ceiling Mount Tile Bridge Model Descripuon Dimensions 2905-9946 Tile Bridge See diagram on page 4 * Refer to data sheet S4905-0003 for additional flash control module information 2 S4906-0003-8 5/2014 S/V Specifications 11 Common Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Specifications Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wirina Speaker Specifications Input Voltage I 25 or 70.7 VRMS, see Note 1 below Powerlaps Ih//2 1 and 2W Fire Alarm Frequency Response General Signaling I 400 to 4000 Hz I 1125 to 12 kHz Wattage Tap 1/4W I W 2W UL Listed Models, Reverberant Chamber Test, per UL 1480 76 dBA 79 dBA 82 dBA 85 dBA Speaker Output Wall Mount Models 4906-9151 and 4906-9153, Ratings © 10 ft (3 m) Anechoic Chamber Test, per ULC-S541 (see Note 1 below) Ceiling Mount Model 4906-9157, 25 VRMS Input per ULC-S541 70.7 VRMS Input 77dBA 80dBA 86 dBA* 83dBA 81.6 dBA 84.3 dBA 87.1 dBA* 89.7 dBA* 80.9 dBA 84.1 dBA 87.3 dBA' 90.2 dBA* ° NOTE: Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-S541 Attenuation I Angle Attenuation I Angle Anechoic Chamber Testing) -3 dB +/- 30° off-axis -6 dB +1- 55° off-axis Strobe Specifications Rated Voltage Range Regulated 24 VDC; 16 VDC to 33 VDC, see Note 2 below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Housing Dimensions (with lens) 71/4 H x 5" Wx 2 %" D (184 mm x 127 mm x 67 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting 15 Cd 30 Cd 75 Cd 110 Cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at 18 VDC other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA -lousing Dimensions Speaker housing = 7 1/3 (191 mm) diameter, %° deep (13 mm); lens protrusion above speaker housing = 2 %" (67 mm); depth into box = 2 3/4 (70 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting 15 Cd 30 cd 75 Cd 110 Cd (75 mA) (125 mA) (233 mA 316 mA Reference RMS Currents at 18 VDC other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: Speakers are for connection to conventional fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. The maximum RMS strobe current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Speaker Directional Characteristics Reference •u•uuuuu•u•u•••i••••i•••..u.u.uuuu• -.UUMENUMNOW -. - . •, uu.uu..wuuu•v•••••i....u•uu••a • - MUMIN NNNRRRU••UN•U•UUUNUNUUNUUUNNNNNN 3 S4906-0003-8 5/2014 IMPORTANTI INSTALLATION MOUNTING HEIGHT REFERENCE 2975-9145 box outline""..,. ,...- 4" square box outline ff 82" (2.1 m) L 1-1/2" i12 (38 mm) minimum NFPA 72 requires that the 78-1/2" (2 m) entire lens be not less than minimum 80" and not greater than 96" above the finished floor. Surface Mounting Reference Showing Optional Wire Guard Surface mount conduit and box shown for reference 4(102mm) square box profile, 1-1/2(38 mm) deep with 1-1/2" extension Optional 4905-9998 Wire Guard Ceiling Mount S/V Installation Reference and Tile Bridge Dimensions 4" (102 mm) square, 1-1/2" (38 mm) deep box with 1-1/2 extension (by others) Wiring input terminals and speaker tap selection are accessible from rear of speaker housing r k-,<--;;;;;y /=-j\ viewing slot Intensity selection plug, accessible only from rear of lens >1 ---housing; factory setting is 15 c ------------------------------ Wall Mount Installation Reference 1' Mounting to 2975-9145 Box - Standard Electrical Box Mounting 4" (102 mm) square box, 1-1/2" 2975-9145 Box _._., / (38 mm) deep, with a 4" square box extension, 1-1/2" deep, by others 0 / 4905-91903 (D— Adapter Plate 7 J1IZ7 t1w, hS1 . \ Wring input terminals and -- I speaker tap selection are I accessible from rear Speaker assembly Strobe assembly Intensity selection Transparent plug, housing and from rear of housing; is Tovabever lens assembly factory setting isi5cd Strobe intensity II Jj viewing slot 1 2905-9946 1/2" (13 mm) [Tile Bridge 0.024" thick sheet metal, folded with 1/2" lip each side 3-3/4" (95 mm) square cutqt centered on plate 1/4" diameter (6 mm) holes, 4 places 23-11/16" (602 mm) 13-3/8" (340 mm) Surface mount adapter skirt, 3-3/16" (81 mm) deep, required for this mounting method: 4905-9946, Red; 4905-9947, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S I rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4906-0003-8 5/2014 © 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-0026:0247 Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4903-9356, -9357, -9358, -9359, -9360, -9361 and *Models 4906-9151 and -9153 TrueAlert Non-Addressable *Wall Mount speaker strobes. Models 4903-9196, -9197, -9198 and *Model 4906-9154 TrueAlert Non-Addressable *Ceiling Mount speaker strobes. *Suitable for indoor use only. Refer to Iiste's data sheet for detailed product description and operational considerations. RATING: Electrical: 25 or 70 V rms, 1/4, 1/2, 1 and 2 Wattage Taps Candela: 4903 -9356, -9359, -9196: 15cd -9197: 30cd -9357,-9360: 75cd -9358, -9361, -9198: 110cd *4906.91519153.9154: 15cd,30cd,75cd, 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number electrical/candela rating and UL label. APPROVAL: Listed as hearing impaired speaker strobes for use with separately listed fire alarm control units. Refer to manufacturer's Installation Manual for details. These devices do not generate a temporal pattern code. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. NOTE: *Rev. 11-22-2004 øv , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTM Operation Compatible Ituii*i Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens . Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: 4006, 4008, 4010, and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control* * 4009 lIDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Wall Mount Strobes Ceiling Mount Strobes I'i*i rirni Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. 71T rn rrni During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. F,llTt1 II]I1* Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NIFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5559492; 5622,427; 5,865,527; 5,886,620; 6,281,789; 6954,137; 7,005,971; and 7,006,003. S4906-0001-4 9/2009 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). IThiiirsT1Ii.i' i* SmartSync two-wire control is available from: 4006, 4008, 4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-993 8 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Product Selection Multi-Candela Visible Notification Appliances (Strobes) iinting Housing Color FIRE Lettering Des ti 4906-9101 Red White 4906-9103 Wall White Red Multi-candela strobe with intensity selectable as: \ 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104) White Red Wall Mount Strobe Adapters 'Model Description ., Dunensns 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 4905-9940 White deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 (200 min 130 min x70 mm) Ceiling Mount Strobe Adapter ModeI Dription Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Descnption Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with ,, - x - x in/out 18 AWG (0.82 mm2) wire leads rated for 2 A NAC, 4905-9922 Class A requires 5 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4"(lo2 mm) square box (lo2mmxlo5 min x32mm) Replacement Covers and Guards Model Description ' Dimension L . 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x 5" W 1-1/2" D For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) * 4905-9961 Wall mount 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9926 Ceiling mount 6-1/8" x 4-3/8" x 2-7/8" deep (156 mmxlii mm x 73 mm) * UL listed by Space Age Electronics Inc 2 S4906-0001-4 9/2009 Wring access hole —1 Ii! io-d- Mounting Holes: Single gang (2) ~\: Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only 75 from rear of housing; 15 factory setting is 15 cd Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (00 to 500 C) Humidity Range 10% to 93%, non-condensing at 1000 F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (1130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd (75 mA) 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r .._Electrical above bottom ii r box outline of compatible \ i-i boxes 1 --7 NFPA 72 requires 80(2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others (T•) LTh 7 0 _(JTh/' 0 Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-4 9/2009 Ceiling Mount Strobe Installation Reference ( Single gang box (Wiremold I V5744S) 2-1/4" (57 mm) deep, supplied by others Handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 1 4905-9910 Adapter Plate, required for O( surface mount with handy box unless using the 4905-9926 wire guard nt strobe 05-9926 wire guard ing plate ------------------ Strobe intensity viewing slot ntensity selection plug, 3ccessible only from rear of lens: lousing: factory setting is 15 Cd I Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square box profile, 1-1/2" eep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco is a registered trademark of Tyco international Services GmbH and is used under license. Simplex, the Simplex logo, iDNet, TrueAlert, and SmartSync are trademarks of Tyco international Ltd and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA. Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4906-0001-4 9/2009 aSimplex www.tycosafetyproducts-usa-wm.com © 2009 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner, acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Outdoor, Selectable. Output Speaker Strobes and Dual- Voltage Evacuation Speakers for Wall Applications SpectrA lertO Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features Weatherproof per NEMA 4X, 1P56 Rated from -40°F to 151°F Plug-in design reduces ground faults Universal mounting plate with onboard shorting spring that tests wiring continuity before devices are installed Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Tamper-resistant construction Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F These speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. Like the entire SpectrAlert Advance line, wall-mount outdoor speakers and speaker strobes include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, speaker voltage and power settings, and automatic selection of 12- or 24-volt operation enable installers to easily adapt devices to meet requirements. Next, these devices use a universal mounting plate with an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verity proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature Agency Listings removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill SIGNAUNG , holes for screw-in mounting. Plastic and metal weatherproof back (t) MEA boxes come with 34-inch top and bottom conduit entries and 3A-inch LISTED approved knock-outs at the back. A screw-in NPT plug with an 0-ring gasket 75S0 7320-1653:201 10-08-E for a watertight seal is included with each back box. SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from -40°F to 150.8°F Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75,30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 6.0'i x 5.0W x 4.7D (including lens and speaker) SP Speaker 6.0'i x 5.0"W x 2.9"D Dimensions, Wall-Mount Weatherproof Back Box 6.5"L x 5.5-H x 2.9'D Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) panels with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1,2 watts AVDSO1301 UL Current Draw Data Candela Derating III UMax. Strobe CurrentDraw :1! For K series products used at low 8 to 17.5 Volts 16 to 33 Volts temperatures, listed candela ratings must be Candela DC FWR DC MD reduced in accordance with this table. 'Strobe 1Output IjI Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 10 110 15 115 35 135 150 150 177 177 185 185 Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sour lM output 1 UL Reverberant (dBA @ 10 ft.) 2W 1W '/2W 1/4 W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe AVOSO100I Surface Mount! _211 RoUl A Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes \ White Red Description SPWF7 SPRK* Outdoor Speaker (includes plastic weatherproof back box) SPSWK*t SPSRKt Outdoor Speaker Strobe, Standard cd (includes plastic weatherproof back box) SPSWK-CLR- - Outdoor Speaker Strobe, Standard cd, Clear Lens, ALERT Printed ALERT (includes plastic weatherproof back box) - SPSRHK Outdoor Speaker Strobe, High cd (135,150,177,185) (includes plastic weatherproof back box) -- White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: *Add "-R" to model number for weatherproof replacement device (no back box included), e.g., SPWK-R. tAdd "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., SPSWK-P. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units, both the device and back box must be replaced. 3825 Ohio Avenue • St. Charles, IL 60174 . , 2Ol25YSta11tSensor. SMSTEIV Product specf cat ons subject to change a,ithout notice. visit systerrrsenssr.carrr .5Ei!5'O4 Phone' 800-SENSOR2 • Fax 630-377-6495 for current product information, including the latest version of this data sheet. AVD301001 .33112 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-1653:0201 Page 1 of 1 CATEGORY: 7320 -- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models SPR,SPW,SPRV, and SPWV SpectrAlert Speakers - Rectangular enclosure. Models SPCW, SPCR, SPCWV, and SPCRV SpectrAlert Speakers with round enclosure. Models SPSR, SPSRH, SPSW, SPSW-ALERT, SPSW-CLR-ALERT, *SPSJII<CLRALERT SPSWH, SPSRV, and SPSWV SpectrAlert Speaker/Strobe with rectangular enclosure. Models SPSCR, SPSCRH, SPSCW, *SPSCWKCLRALERT SPSCWH, SPSCRV, SPSCRVH, SPSCVW, and SPSCWVH SpectrAlert Speaker/Strobe with round enclosure. Model SPSCW-CLR-ALERT Speaker/Strobe. Model SPSW-ALERT has amber lens and is intended for non-fire use. All models identified are intended for indoor use mounted on the wall or ceiling. Models with a "K" in the suffix are suitable for indoor or outdoor use with an operating temperature rating of -40°C to +66°C (-40°F to +151°F) and have a NEMA 4X enclosure rating when used with models PWBB, PWBBW (wall) or the model PWBBCW (ceiling) plastic weatherproof back boxes or with Model MWBBW (Wall), MWBB (Wall) or MWBBCW (Ceiling) metal weatherproof back boxes. Models with a "- P' in the suffix have plain housings with no lettering on the enclosure. Models not containing "- P", in the suffix have English lettering reading "FIRE" on the housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Nominal Voltage: 25 Vrms or 70 Vrms Power Settings: 1/4, %, 1, 2 Watts Frequency Range: 400 - 4000 Hz INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as speaker/strobes when used with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. These speaker/strobes do not generate a distinctive three-pulse temporal code pattern (for total evacuation) as required per NFPA 72, 2010 edition. If required, the appliances must be used with a fire alarm control unit that can generate the temporal pattern signal. *Corrected 02-06-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division License Number 986047 Extract Date: 03-18-2014 SIMPLEX GRINNELL L P Business 12728 SHOEMAKER AVENUE Information SANTA FE SPRINGS, CA 90670 Business Phone Number: (562) 405-3800 Entity: Partnership Issue Date 8/14/2013 Expire Date 8/31/2015 License Status This license is current and active. All information below should be reviewed. Additional Status: C10 ELECTRICAL Classifications: C16 FIRE PROTECTION CONTRACTOR CONTRACTOR'S BOND I This license filed Contractor's Bond number 82332032 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Contractors Bonding History Bonding: 1. This license filed Bond of Qualifying Individual number 82332032 for MAYLE RONALD GILBERT in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 BQI's Bonding History 2. This license filed Bond of Qualifying Individual number 82332035 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 BOIs Bonding History This license has workers compensation insurance with the ACE AMERICAN INSURANCE COMPANY Workers' Policy Number:WLRC47323484 Compensation: Effective Date: 10/01/2013 Expire Date: 10/01/2014 Workers' Compensation History - SimplexGrinnell LP SimplexGr:nnell BE SAFE. 3568 Ruffin Road, South San Diego, CA 92123-2597 A Tyco International Company Tele: (858) 633-9100 Fax: (858) 633-9101 www.simolexorinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 1/3/2013 REV.#: 0 PROJECT #: 480-)00000(-XX/X)0000000(