HomeMy WebLinkAbout2525 EL CAMINO REAL; ; AS120040; Permit11/14/24,2:07 PM AS 120040 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS120040
2525 EL CAM INO
Job Address:
REAL
Permit Type: SPRINK
Parcel No: 1563020900
Lot #: 0
Reference No.:
PC #:
Project Title: RUE 21 T.I.
Status: PENDING
Applied 3/28/2012
Approved:
Issued:
Inspector:
Applicant:
A& D FIRE SPRINKLERS, INC.
2ND FLOOR
11465 WOODSIDE AVE
SANTEE, CA 92071
619-448-1962
Owner:
PLAZA CAM INO REAL
C/O WESTFIELD PROPERTY TAX DEPT
P0 BOX 130940, DEPT WFLD
CARLSBAD, CA
Fees ($) Add'I Fees _($)j Total ($) Balance ($)
262 0 262 0
about:blank 1/1
FIRE SPRINKLERS INC.
RUE 21
2525 EL CAMINO REAL, STE 161
CARLSBAD, CA 92008
FIRE SPRINKLER SUBMITTAL
MANUFACTURER'S DATA SHEETS
** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in
the construction schedule and shall be deemed accepted by the Purchaser.
ttlCa /Fire & Building
I Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
Series 7V-FRB - 2.8, 4.2, 5. 6, and 8.0 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The Series TY-FRB, 2.8, 4.2, 5.6, and
8.0 K-factor, Upright and Pendent
Sprinklers described in this data sheet
are quick response - standard cover-
age, decorative 3 mm glass bulb type
spray sprinklers designed for use in
light or ordinary hazard, commercial
occupancies such as banks, hotels,
shopping malls, etc.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where ap-
plicable, is intended for use in areas
with a finished ceiling. It uses either a
two-piece Style 10 (1/2 inch NPT) or
Style 40 (3/4 inch NPT) Recessed Es-
cutcheon with 1/2 inch (12,7 mm) of
recessed adjustment or up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendert position, or a two-piece
Style 20 (1/2 inch NPT) or Style 30 (3/4
inch NPT) Recessed Escutcheon with
1/4 inch (6,4 mm) of recessed adjust-
ment or up :0 1/2 inch (12,7 mm) of
total adjustment from the flush pen-
dent position. The adjustment pro-
vided by the Recessed Escutcheon re-
duces the accuracy to which the fixed
pipe drops to the sprinklers must be
cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of coppEr alloy sprinklers beyond
that which would otherwise be ob-
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the 'INSTALLER
WARNING that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkle.- system or its compo-
nents and cause the sprinkler to fail
to operate 'n a fire situation or cause
it to operate prematurely.
tamed when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
An intermediate level versions of the
Series TY-FRB Pendent Sprinklers
are detailed in Technical Data Sheet
1FP356, and Sprinkler Guards are de-
tailed in Technical Data Sheet TFP780
WARNINGS
The Series TY-FRB Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Model/Sprinkler
Identification
Numbers
TY1I3I - Upright 2.81K, 1/2"NPT
TY1231 - Pendent 2.81K, 1/2"NPT
1Y2131 - Upright 4.21K, 1/2"NPT
TY2231 - Pendent 4.21K, 1/2"NPT
TY3131 - Upright 5.6K, 1/2"NPT
1Y3231 - Pendent 5.61K, 1/2"NPT
TY4131 - Upright 8.0K, 314"NPT
TY4231 - Pendent 8.01K, 314"NPT
Page 1 of 10 APRIL, 2006 TFPI7I
SSP DEFLECTOR*
ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20
PLATE SEATING 1/2" ** NOMINAL RECESSED
SURFACE MAKE-IN ESCUTCHEON NPT i
2-7/8" (73,0 mm) DIA.
ssU *
DEFLECTOR
7/16"
(11,1 mm) I NOMINAL I
MAKE-IN
I 2-3/16"
WRENCH (55,6 mm)
FLATS
1/2" NPT**
'RENCH.
FLATS
Page 2 of 10 TFPI7I
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5- Compression 7- Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
ESCUTCHEON
PLATE SEATING
SURFACE
2-3/16"
(55,6 mm)
1-1/2"
(38,1 mm)
7/16" (11,1 mm) STYLE 10or20
NOMINAL RECESSED ,,
MAKE-IN ESCUTCHEON SSU *
DEFLECTOR
LN
NOMINAL
i,
4
SSP DEFLECTOR* h — 2-7/8" (73,0 mm) DIA.
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS
4.2 K-FACTOR, 112 INCH NPT
7/16" (11,1 mm) STYLE 10or2(
NOMINAL RECESSED
MAKE-IN ESCUTCHEOI
2-7/8" (73,0 mm) DIA. SSP DEFLECTOR*
ESCUTCHEON
PLATE SEATING
SURFACE
T_
2-3/16"
Al
(55,6 mm)
(38,
!II i]II'1.I
7/1
NOMINAL
'JH
4
ESCUTCHEON 1/2(12,7mm) STYLE 30 0r40
PLATE SEATING ** NOMINAL 3/4 RECESSED
SURFACE MAKE-IN ESCUTCHEON NPT
2-5/16"
(58,7 mm)
1-9/16"
W
(39,7 mm) WRENCH
FLATS
'1
SSP DEFLECTOR*2-7/8" (73,0 mm) DIA.
PENDENT RECESSED PENDENT
SSU *
DEFLECTOR
6*
1/2"
(12,7 mm)
NOMINAL
MAKE-IN
2-1/4"
(57,2 mm) 3
3/4 NPT**
UPRIGHT CROSS SECTION
TFPI7I Page 3 of 10
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT
1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS
8.0 K-FACTOR, 314 INCH NPT
Page 4 of 10 TFPI7I
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
SPRINKLER FINISH (S"
POLYESTER
I CHROME
PLATED
2.8
PENDENT
(TY1231)
and
UPRIGHT
(TYI13I)
135°F/57°C Orange
1,2,3,5 155°F/68°C Red
175°F/79°C Yellow
200°F193°C Green
286°F/141°C Blue
1/2"
NPT 135°F/57C Orange
1, 2, 5
RECESSED
PENDENT
(TY1231)
Figure 5
155F/68°C Red
175°F/79C Yellow
2O0FI93°C Green
RECESSED
PENDENT
(TY1231)**
Figure 6
135°F/57°C Orange
155°F/68°C Red
175°F/79C Yellow
200°F/93°C Green
4.2
1/2"
NPT
PENDENT
(TY2231)
and
UPRIGHT
(TY2131)
135F/57*C Orange
1,2
155°F168°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141°C Blue
RECESSED
PENDENT
(TY2231)*
Figure 7
135°F157°C Orange
155°F168oC Red
175°F179°C Yellow
200F/93C Green
RECESSED
PENDENT
(TY2231)**
Figure 8
135°F/57°C Orange
155°F168°C Red
175°F/79°C Yellow
200°F/93°C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re-
sponse Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin-
klers.
5. Approved by the City of New York under MEA 354-01-E.
7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin-
klers are UL and C-UL Listed as Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment
Recessed Escutcheon, as applicable.
** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment
Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to color (Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
Technical
Data
Approvals
UL and C-UL Listed.
FM, LPCB, and NYC Approved.
(Refer to Table A and B for complete
approval information including corro-
sion resistant status.)
Maximum Working Pressure
Refer to Table C.
Discharge Coefficient
K = 2.8 GPM/psi112 (40,3 LPM/barl'2)
K = 4.2 GPM/psi112 (60,5 LPM/bar112)
K = 5.6 GPM/psi112 (80,6 LPM/barll2)
K = 8.0 GPM/psi112 (115,2 LPM/barll2)
Temperature Ratings
Refer to Table A and B
Finishes
Sprinkler: Refer to Table A and B.
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated.
Physical Characteristics
Frame ............Bronze
Button ........Brass/Copper
Sealing Assembly ..........
Beryllium Nickel w/Teflont
Bulb ..............Glass
Compression Screw .....Bronze
Deflector .......Copper/Bronze
Bushing (K=2.8) .......Bronze
Operation
The glass Bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The Series TY-FRB Pendent and Up-
right Sprinklers are intended for fire
protection systems designed in ac-
cordance with the standard installation
rules recognized by the applicable
Listing or Approval agency (e.g., UL
Listing is based on the requirements of
NFPA 13, and FM Approval is based
on the requirements of FM's Loss Pre-
vention Data Sheets ). Only the Style
10, 20, 30, or 40 Recessed Escutch-
eon, as applicable, is to be used for
recessed pendent installations.
TFPI7I Page 5 of 10
SPRINKLER FINISH (See Note 8)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
I CHROME
PLATED
FWHITE
T
*"
LYESER
LEAD
COATED
5.6
PENDENT
(TY3231)
and
UPRIGHT
(TY3131)
135°F/57°C Orange
1, 2,3,4,5,6,7 1,2,3,5 155F/68C Red
175°F/79C Yellow
200F/93C Green
286°F/141C Blue
1/2'
NPT 135°F/57°C Orange
1,24,5 N/A
RECESSED
PENDENT
(TY3231)*
Figure 9
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
135°F/57°C Orange
1,2,3,4,5
I
I
I I 1,2,4,5 I
Green
N/A
RECESSED
PENDENT
(TY3231)**
Figure 10
155F/68°C Red
175F/79°C Yellow
200°F/93°C
8.0
PENDENT
(1Y4231)
and
UPRIGHT
(TY4131)
135F/57C Orange
1,2, 3,4,5,6,7
1,2,5 155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286F/141C Blue
3/4'
NPT
RECESSED
PENDENT
(TY4231)*
Figure 11
135°F/57°C Green
1, 2, 4, 5 N/A 155°F/68C Orange
175FI79°C Red
200°F/93C Yellow
RECESSED
PENDENT
(TY4231)**
Figure 12
135°F/57°C Orange
1,2,3,4, 5 N/A
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the
LPCB does not rate the thermal sensitivity of recessed sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377).
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers.
Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a
Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable
** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to color (Special Order).
N/A: Not Available
TABLE B
LABORATORY LISTINGS AND APPROVALS
5.6 AND 8.0 K-FACTOR SPRINKLERS
Page 6 of 10 TFPI7I
SPRINKLER FINISH
K TYPE NATURAL I CHROME WHITE LEAD
BRASS PLATED POLYESTER I COATED
PENDENT (TY3231)
and
2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A
1/2 RECESSED PENDENT NPT (TY323)
PENDENT (TY4231)
and
4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A
3/4,, RECESSED PENDENT NPT (TY4231)
PENDENT (TY3231)
and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR)
5.6 UPRIGHT (TY3131) OR
1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A
PENDENT (TY4231)
and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR)
8.0 UPRIGHT (TY4131)
3/4,, RECESSED PENDENT NPT (TY4231) N/A
NOTES:
1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by
Underwriters Laboratories, Inc. for use in Canada (C-UL); and ,the Approval by the City of New York.
TABLE C, MAXIMUM WORKING PRESSURE
Installation
The Series TY-FRB Sprinklers must
be installed in accordance with the fol-
lowing instructions:
NOTES
Do not install any bulb type sprinkler if
the bulb is cracked or there is a loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/57°C to 3/32
inch (2,4 mm) for the 286 °F/14 1°C
temperature ratings.
A leak tight 1/2 inch NPT sprinklerjoint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28,5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 ft.lbs.
(13,4 to 26,8 Nm). A maximum of 30
ft.lbs. (40,7 Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-FRB Pendent and Up-
right Sprinklers must be installed in
accordance with the following instruc-
tions.
Step 1. Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 13).
With reference to Figures 1, 2, 3, and
4, the W-Type 6 Sprinkler Wrench is to
be applied to the sprinkler wrench
flats.
The Series TY-FRB Recessed Pen-
dent Sprinklers must be installed in
accordance with the following instruc-
tions.
Step A. After installing the Style 10.
20, 30, or 40 Mounting Plate, as appli-
cable, over the sprinkler threads and
with pipe thread sealant applied to the
pipe threads, hand tighten the sprin-
kler into the sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 14). With reference to Figure 1,
21 3, and 4, the W-Type 7 Recessed
Sprinkler Wrench is to be applied to
the sprinkler wrench flats.
Step C. After the ceiling has been in-
stalled or the finish coat has been ap-
plied, slide on the Style 10, 20, 30, or
40 Closure over the Series TY-FRB
Sprinkler and push the Closure over
the Mounting Plate until its flange
comes in contact with the ceiling.
TFPI7I
- 2-718' DIA. -
5/8±114" (73,0 mm) 3/4"(19,1 mm)
(15,9±6,4 mm)
_ 2-1/4" DIA. 114' (6,4 mm)
FACE OF MOUNTING
SPRINKLER PLATE I
FITTING
I 1/8"
I
(3,2 mm)
MOUNTING
CLOSURE SERIES 1-5/16' (33,3 mm)
SURFACE
TY-FRB 13/16"(20,6 mm)
FIGURE 5
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
2-7/8' DIA. -
5/8±1/4"
(73,0 mm) 3/4"(19,1 mm)
(15,9±6,4mm)
_ 2-1/4' DIA. 1/4"(6,4 mm) I
FACE OF MOUNTING
SPRINKLER I PLATE
FITTING
1/8'
(3,2 MM)
'1
F MOUNTING
SURFACE
SERIES 1-114'(31,8 mm)f CLOSURE TYFRB 3/4"(19,1 mm)
FIGURE 7
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
Page 7 of 10
- 2-7/8" DIA.
(73,0 mm) 1/2±1/8' 1/2"(12,7 mm)
E (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I
SPRINKLER PLATE
FACE OF [572mm)
-1
MOUNTING
FITTING
'I _______________
1/8'
M(3,2 mm)
MOUNTING /
I16"
/1
SURFACE/f
(33,3 mm) CLOSURE SERIES
TY-FRB 1-1/16"(27,0 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
2-7/8" DIA.
(73,0 mm)
1/2±1/8" 1/2"(12,7 mm)
E (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I
I SPRINKLER PLATE
FACE OF 1Z57,2 mm) MOUNTING
I FITTING
1/8' I
______
MOUNTING
SURFACE
SERIES l-l/4'(31,8mm) CLOSURE TYFRB 1"(25,4 mm)
FIGURE 8
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
Care and
Maintenance
The Series TY-FRB Sprinklers must
be maintained and serviced in accord-
ance with the following instructions:
NOTES
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
The owner must assure that the sprin-
klers are not used for hanging of any
objects; otherwise, non-operation in
the event of a fire or inadvertent opera-
tion may result.
Absence of an escutcheon, which is
used to cover a clearance hole, may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
Page 8 of 10
2-718" DIA. -
5/8±1/4"
(73,0 mm) 3/4"(19,1 mm)
(15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) I
FACE OF MOUNTING
SPRINKLER PLATE I
FITTING
1/8'
(3,2 mm)
MOUNTING
SURFACE
SERIES 1-1/4" (31,8 j
711~~
I
CLOSURE TY-FRB 3/4" (19,1 mm)
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
2-7/8" DIA. _ I (73,0 mm)
2-1/4" DIA.
3/4"(19,1 mm)
1/4"(6,4 mm)
(57,2 mm) MOUNTING
1/8"
(3,2 mm)
t
1-5/16" (33,3 mm)t
13/16(20,6 mm)
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
TFPI7I
2-7/8" DIA.
1/2±1/8" (73,0 mm) 1/2" (12,7 mm)
E (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm)
SPRINKLEqR PLATE
FACE OF 572 mm) MOUNTING
FITTING
1/8" I
SURFACE
(32mm)
IMOUNTIN
CLOSURE SERIES 1-1/4(31,8 mm)
TYFRB 1" (25,4 mm)
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
2-718"DIA.
1/2±1/8" (73,0 mm) 1/2"(12,7 mm)
r (12,7±3,2 mm) - 2-1/4" DIA. 1/4"(6,4 mm)
I FACE OF
(57.2 MM) MOUNTING I SPRINKLER PLATE
I FITTING 1/8"
(3,2 mm)
MOUNTING
SURFACE
CLOSURE SERIES 1-5/16"(33,3 mm)
TY-FRB 1-1/16" (27,0 mm)
FIGURE 12
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
5/8±1/4"
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
MOUNTING
SURFACE
CLOSURE SERIES
TY-FRB
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative
to any questions.
It is recommended that automatic
sprinkler systems be inspected,
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 13
W-TYPE 6 SPRINKLER
WRENCH
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 14
W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFPI7I Page 9 of 10
P/N 57-XXX-X-XXX
MODEL/SIN
330 2.8K UPRIGHT (1/2"NPT) TY1131
331 2.8K PENDENT (1/2"NPT) 1Y1231
340 4.2K UPRIGHT (1/2"NPT) TY2131
341 4.2K PENDENT (1/2"NPT) TY2231
370 5.6K UPRIGHT (1/2"NPT) TY3131
371 5.6K PENDENT (1/2"NPT) TY3231
390 8.OK UPRIGHT (3/4"NPT) TY4131
391 8.0K PENDENT (3/4"NPT) TY4231
I I I SPRINKLER
[
I NATURAL BRASS
4 WHITE POLYESTER
3 WHITE (RAL9010)*
9 CHROME PLATED
7 LEAD COATED
I
135
155
175
200
286
TEMPERATURE
RATING
155*F/68*C
175°F179°C
2000F/93*C
286°F/141°C
* Eastern Hemisphere sales only.
TABLE D
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor
authorizes any person to assume for it,
any other obligation in connection with
the sale of products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or inac-
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
whole or part, of any portion of this
warranty will not affect the remainder.
Ordering
Procedure
When placing an order, indicate the
full product name. Refer to the Price
List for complete listing of Part Num-
bers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (Specify Model/SIN), Quick
Response, (specify K-factor), (specify
temperature rating), Series TY-FRB
(specify Pendent or Upright) Sprinkler
with (specify type of finish or coating),
P/N (specify from Table D).
Recessed Escutcheon:
Specify: Style (10, 20, 30, or 40) Re-
cessed Escutcheon with (specify*) fin-
ish, P/N (specify*).
* Refer to Technical Data Sheet TFP770.
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
Page 10 of 10 TFPI7I
TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
p1 ulini
Im
J.'A wor,
iiiii APML9tar M&NVIL 4 NEW. (' '
Anvil's Unmatched Piping Products for Every Industry
Anvil provides the most comprehensive line of innovative, durable, and reliable pipe
connections, support systems, and customer service.
For more than 150 years, Anvil has provided integrated, reliable piping solutions for a variety of applications. With
the most complete line of piping products, expert design services, and a responsive customer service team, Anvil's
total package is unmatched throughout the industry. Our professionals will work with you to develop innovative
solutions that meet your demands and exceed your expectations.
From HYAC, plumbing and mechanical to fire protection, mining, oil and gas, and gas utilities, Anvil covers all
markets. Our extensive product line includes grooved couplings, fittings, and valves; cast and malleable pipe fittings;
forged steel fittings and unions; steel pipe nipples and couplings; pipe hangers and supports; strut and channel; oil
country fittings; and valves. Our exceptional market-specific expertise ensures you always get the best solution for
your unique application.
In addition to Anvil's extensive line of domestically manufacture products, Anvil also offers a full line of Globally
manufactured malleable iron fittings and steel pipe nipples. These products are manufactured within ISO 9001:2000
facilities where Anvil's quality control engineers oversee the entire process. Anvil is committed to providing the
finest quality pipe fittings available, which we believe only a true manufacturer can provide. Engineered drawings of
fittings andnipples along with detailed inspection procedures, leave no questions regarding Anvil's commitment to
quality imported products.
With 150 years of manufacturing expertise, Anvil is in a unique position to set the highest quality standard for both
domestic and import products. Anvil's specifications for SPF malleable fittings and pipe nipples are higher than
typical ANSI specification. The SPF malleable fittings are UL Listed and FM Approved.
Building Con,e,,Th,tL,.
Standard Welded Anvil International is the only manufacturer where
you can combine your import and U.S. Manufactured
product requirements.
Dimensional: I ASTM A733
Material: } ASTM A53 Type F or Type E
Galvanizing: I Hot Dip Galvanizing
Threading:88 I ASME B 1.20.1
Standard End Finish
Tapered Pipe Thread (NPT)
8Gclvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process.
"British Standard threading per BS 21 available upon request.
Ends are cut square to the central axis. All burrs on
the inside are removed. The ends of the pipe nipples
are chamfered on the outside at an angle of 35' +1-
10' to the cemral axis.
Pipe nipples are threaded on both ends with
standard NPT tapered threads. Threads are right
hand on both ends.
Also available:
Ready Cut Pipe, Standard - Schd. 40 (black and galvanized)
Pipe Size: 1/2,3/4, 1", 11/4 , 11/2 , 2"
Pipe Length: 8", 24", 3011, 4811, 60", 72"
"66" Packs, Standard - Schd. 40 (black and galvanized)
Nipple Size: '/2", 3/4', 1, 11/4 , 11/2 , 2"
Single Run Nipple Packs (black and galvanized)
Pipe Size: '/2", 3/4, 1, 11/4", 1V2, 2"
I
1/8 ' .405 I 3/4 1 1 /2 2 '2'/2 '
Ti1Nipple
3 '3'/2' 4 '4'/2'
and
5 '5'/2' 6 ' 7 ' 8 ' 9 10 11 ' 12'
1/ .540 7/8 1 1/2 221/2 331/2 441/2 55 1/2 6 789101112
.675 1 1/2 2 2'/2 3 3'/2 4 41/2 5 51/2 6 7 8 9 10 11 12
1/2 .840 1 1/8 1 /2 2 21/2 3 3'/2 4 4 1/2 5 51/2 6 7 8 9 10 11 12
3/4 1.050 1 /8 11/2 2 2'/2 3 3 1/2 4 1 4 1/3 5 5'/2 6 7 8 9 10 11 12
1 1.315 1 1/2 2 2'/2 3 3 1/2 4 41/2 5 51/3 6 7 89 10 11 12
1 1/4 1.660 1 /8 2 2 '/2 3 31/2 4 41/2 5 5 /2 6 7 8 9 10 11 12
1 '/2 1.900 1/4 2 2'/2 3 3'/2 4 41/2 5 5 72 6 7 8 9 10 11 12
2 2.375 2 2'/2 3 31/2 4 41/2 5 5'/2 6 7 8 9 10 11 12
2'/2 2.875 2 1/2 3 3'/2 4 4'/2 5 51/3 6 7 8 9 10 11 12
3 3.500 2/8 3 3'/2 4 4 /2 5 5'/2 6 7 8 9 10 11 12
4 4500 - 2 /8 4 4 5 5 1/ 6 7 8 9 10 11 12
6 6.625 3 /8 4 4 '/2 5 5 '/2 6 7 8 9 10 11 12
AWIL
&dMlngC•,,,ThtL
Extra Heavy - SCH. 80 Welded Anvil International is the only manufacturer where
you can combine your import and U.S. Manufactured
product requirements.
Dimensional: I ASTM A733
Material: I ASTM A53 Type F or Type E
Galvanizing: I Hot Dip Galvanizing*
Threading: I ASME B 1.20.1
Standard End Finish
Tapered Pipe Thread (NPT)
*Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process.
Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the
outside at an angle of 35 +1- 10 to the central axis.
Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends.
Pipe
Size O.D.
18
Pipe Length
Close
.405 3/4 1 1/2 2 2 /2
Pipe
3
Nipple Lengths
3 l/ 4 4 1/2 5
(Black
5 1/
and galvanized)
6 7 8 9 10 11 12
1/4 .540 7/ 1 1/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12
.675 1 1 1/2 2 21/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12
1/3 - .840 1 1/8__- 1 1/2 2 21/2 3 31/3 4 41/2 5 51/3 6 7 8 9 10 11 12
3/4 1.050 1 /8 1 1/3 2 21/2 3 31/2 4 41/2 5 51/3 6 7 8 9 10 11 12
P 1 1.315 1 1/2 2 21/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12
1 1/4 1.660 1 5/8 2 2/2 3 31/2 4 4 1/2 5 51/2 6 7 8 9 10 11 12
1 1/2 1.900 1/4 2 1 21/2 3 31/3 4 1 4 1/2 5 51/2 6 7 8 9 10 11 12
2 2375 2 21/2 3 372 4 41/2 5 5'/2 1 6 7 8 9 1 10 11 12
21/2 2.875 21/2 3 1 372 4 41/2 5 51/2 6 7 8 1 9 10 111 12
3 3.500 2/ 3 3 '/2 4 4 '/2 5 51/ 6 7 8 9 10 11 12
3 1/2
-
4.000 2/4 4 4 1h 5 51/2 6 7 8 9 10 11 12
4 4.500 2/e 4 41/2 5 51/2 6 7 8 9 10 11 12
5 1 5.563 1 3
- - -
4 1 41/ 5 1 5 1/2 6 1 7 8 9 10 11 12
6 6.625 1 3 1/8 4 1 4 1/2 5 51/2 6 1 7 8 9 10 11 12
Building Connetgo.0 That I45t
Extra Heavy Seamless Anvil International is the only manufacturer where
you can combine your import and U.S. Manufactured
product requirements.
Dimensional: I ASTM A733
Material: I ASTM Al 06 Grade B
Galvanizing: I Hot Dip Galvanizing*
Threading: I ASME B 1.20.1
Standard End Finish
Tapered Pipe Thread (NPT)
*Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process.
Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the
outside at an angle of 350 +1- 10° to the central axis.
Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends.
Pipe Pipe
Size O.D.
I 1/8 .405
Length
Close
gp
3/4 1 1/2 2 21/2
Pipe
3
Nipple
3 /2 4
Lengths
I 41/3
(Black
I I
5 5 1/2
and galvanized)
I I
6 7 8
I I
9 10
I
11 12
1/4 .540 /8 1 1/2 2 2'/2 3 312 4 41/2 5 51/2 6 7 8 9 10 11 12
.675 1 1 1/2 2 21/2 3 31/2 4 472 5 51/2 6 7 8 9 10 11 12
1/2 1 .840 118 1 1/2 1 2 21/2 3 3 72 4 41/2 5 51/3 6 7 8 9 10 11 12
3/4 1.050 1 /8 11/2 2 21/2 3 31/2 4 41/2 5 572 6 7 8 9 10 11 12
1 1.315 1 1/2 2 21/2 3 31/3 4 41/2 5 51/2 6 78 9 10 11 12
]1/4 1.660 1 5/ 2 272 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12
1 1/2 1.900 1/4 2 2'I2 3 31/2 4 41/2 5 5'/2 6 7 8 9 10 11 12
2 2.375 2 2 1/2 3 31/ 4 4'/2 5 51/2 6 7 8 9 10 11 12
2 1/2 2.875 2 1/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12
3 E..500 2/s 3 3 '/2 4 41/3 5 51/2 6 7 8 9 10 11 12
4 &500 2/s 4 41/a 5 51/2 6 7 8 9 10 11 1 12
5 5.563 3 41/2 5 51/2 6 7 8 9 10 11 12
6 6.625 31A 4 1/2 5 5 6 1 7 8 9 10 11 12
AWIL
.dIdingCon0.00n0Th0tL00t
Class 150 (Standard)
STANDARDS ISPECIFICATIONS
IImport iI!lMalleableIron IScrewed •fflFY3(l(ClassF15I0)
Dimensional: Fittings:
Unions:
Bushings/Plugs:
ASME B16.3
ASME B 16.39
ASME B 16.14
Material: i ASTMA-197
Galvanizing: ASTMA-153 (Hot Dip Galvanizing)
Threading:* ASME B 1.20.1
Pressure Rating:
Unions: -
Bushings/Plugs:
B 16.3
ASME B 16.39
ASME B 16.14
Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. - -
Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved.
British Standard threading per BS 21 available upon request.
900 REDUCING ELBOW in
1/4 X /8
I.
0.74
'1TIfl
I. I.,.
0.76 0.08 1
•
B ---a
-I
-
f
I •
%x¼ 0.81 0.85 0.11
0.88 0.90 0.13
097 - 098 016
/2X 3/8 1.04 1.03 0.19
1.12 1.13 0.26
/4x½ 1.20 1.22 - 0.29
1 X 1/2 1.26 1.36 0.42
1 x 3/4 1.37 1.45 0.47
1 ¼ X 1/2 1.34 1.53 0.54
1 1/4 x 3/4 1.45 1.62 0.62
1 ¼x 1 1.58 1.67 0.73
-
- 1 1/2 X 1 -- 1.65 1.80 0.88
1 V2x 1 1/4 1.82 1.88 1.03
2x 3/4 1.60 1.97 1.04
2 x 1 1.73 2.02 1.28
2 x 1 14 1.90 2.10 1.36
2x1V2 202 - 216 151 -
- 2'/2x1 ½ 2.16 2.51 2.20
2 1/2 x 2 2.39 2.60 2.55
3 x 2 2.52 2.89 3.35
3x2 1/2 2.83 2.99 4.12
4 x 3 - - 3.30 3.60 6.65
-. www.anvilinti.com AWIL
0dWh,gCo,,*n.
Class 150 (Standard)
900 ELBOW
1fr4.
I.
1/8
A
I.
0.69
'ATtt11
I.;.
0.06
¼ 0.81 0.10
0.95 0.15
½ 1.12 0.22
-
3/4 1.31 0.36
1 1.50 0.57
1¼ 1.75 0.87
-
1½
--
1.94 1.16
2 2.25 1.81
2½ 2.70 3.23
3 3.08 4.82
4 3.79 8.41
6 5.13 19.96
450 ELBOW
ifr4 -
I.
A
II
Weight
1.1.
I I 1/8
I
0.63 0.06
¼ 0.73 0.11 -'
0.80 0.14
½ 088 0.20
3/4 0.98 0.32
1 1.12 0.50
1 1h 1.29 0.76
1 1/ 1.43 1.00
2 1.68 1.61
2 - -- 195 2.77
rJr(_'2 3 2.17 4.03
1 4 2.61 6.92
6 3.46 16.31
AWIL
Build/nc Coflntctito.S That Lost
Class 150 (Standard)
jfr4.
90° STREET ELBOW
in II II 1.7.
1/8 0.69 1.00 0.05
1/4 0.81 1.19 0.09
*i''1ll1ilhi /8 0.95 1.44 0.15
½ 112 163 020
3/4 1.31 1.89 0.34
1 1.50 2.14 0.58
1 1/4 1.75 2.45 0.84
- 1 ½ 1.94 2.69 1.12
2 2.25 3.26 1.85
2½ 2.70 3.86 3.28
3 3.08 4.51 5.00
4 3.79 5.69 9.18
45° STREET ELBOW
1L.L
.1
.1fr4.
in
½
in
0.63
in
0.83
1.7.
0.05
1/ 0.73 0.94 0.08
% - 0.80 1.03 0.12
½ 0.88 1.15 0.18
'/4 0.98 1.29 0.27
1 1.12 1.47 0.44
1 ¼ 1.29 1.71 0.70
1 1/2 143 188 092
2 1.68 2.22 1.50
Size A Weight
CROSS
in II I.j.
/4 0.81 0.17
1) /8 0.95 0.26 I_ 1/2 1.12 0.38
A A 3/4 1.31 0.61
- A 1 1.50 0.95
---H--- 1 1/4 1.75 1.42
-
A 1 1/2 1.94 1.86
2 2.25 2.83
8 www.anviIintl.com
Class 150 (Standard)
CAP
1
j.
Size
in
1/8
A
It
0.53
Weight
I.j.
0.03
1/4 063 005
-
3/ 0.74 0.07
1/2 0.87 0.11
1.16 0.30
1 1/4 1.28 0.44
1 1/ 1.33 0.55
2½ 1.70 1.49
3 1.80 2.20
3 ½
-
1.90 3.02
4 2.08 3.79
6 255 - 877
TEE
-7
I
FI-4 JLJ
[j
II
I
1/8
Size TATLTI
II
0.69
I
I.;.
0.09
Y4 0.81 0.14
0.95 0.21
1/2 0.31
-:
0.50
0.79
1 1/4 1.75 1.19
1 ½ 1.94
-
1.57
2.25 2.43 -2
2 ½ 2.70 4.33
3 3.08 6.37
4 3.79 11.03
AWIL
8,llthflgCe,n,Mown
Class 150 (Standard)
REDUCING TEE I. II II in lbs
1/4 0.97 0.97 0.98 0.24
1.04 1.04 1.03 027
1/2 1/2
:
0.37
0.49
½ 1.20 1.12 1.22 0.38
1/2 3/4 1.31 1.22 131 045
- 1/4 1.05 1.05 1.08 0.36
%1.12 1.12 1.13 0.39 3/4
1/2 1.20 1.20 1.22 0.43
- 1 1.45 1.45 137 0.62
1/4 1 1.50 1.18 1.50 0.63
½ 1.26 1.12 1.36 0.48
1/2 3/4 1.37 1.22 1.45 0.56
1 150 136 150 067
½ 1.26 1.20 1.36 0.53
3/4 3/4 1.37 131 1.45 0.61
1
O .62
1.45
1 1/4 1.67 1.67 1.58 0.94
1 ½ 1.80 1.80 1.65 1.07
2 2.02 2.02 1.73 1.45
1 1.58 1.36 1.67 0.82
½ 1 1/4 1.75 1.53 1.75 0.95
3/4 1.45 1.31 1.62 0.75
3/4 1 1.58 1.45 1.67 0.87
1 1/4 - 1.75 1.62 1.75 1.00
½ 1.34 1.26 1.53 0.74
3/4 1.45 1.37 1.62 0.82 1'/4 1 1 1.58 1.50 1.67 0.94
11/4 1.75 1.67 1.75 1.08
½ 1.34 1.34 1.53 0.84
3/4 1.45 145 1.62 0.92
1 1/4 1 1.58 1.58 1.67 1.04
CONTINUED 1½ - 1.88 1.88 1.82 1.34
ON NEXT PAGE. 2 2.10 2.10 1.90 1.65
t,il&ng ConnectSn, That inn
Class 150 (Standard)
REDUCING TEE
I
•
II I
'? C
I
1 ½
1tI'4-
II
1/2 1 ½
I.
1.94
in
1.66
II
1.94
Ibs
1.24
1.50 1.26 1.69 0.86
1½ 1.94 1.94 1.29 -
1 1 1/4 1.82 1.67 1.88 1.23
1½ 194 1.80 1.94 1.35
1 1/4
3/4 1.52 1.45 1.75 1.04
1 1.65 1.58 1.80 -1.17
-- 1 1/4 1.82 1.75 1.88 1.32
1 1/2 1.94 1.88 1.94 1.45
1 ½
½ 1.41 1.41 1.66 1.04
1.52 1.52 1.75 1.14
1 1 1.5 1.65 1.80 1.27
1 1/4 182 182 188 143
2 2.16 2.16 2.02 1.89
1.89
2
/2 2 2.25 1.88 225
3/4 2 2.25 1.97 2.25 1.93
1 2 225 202 - 225 200'
1 1/4
1 1/4 1.90 1.75 2.10 1.64
1½ 2.02 1.88 - flo 1.80
2 2.25 2.10 2.25 2.09
1½
1 1.73 165 2.02 157
1 1/4 1.90 1.82 2.10 1.71
77 1½ 2.02
2.25 2.16
1.94216 1.88 --
2.21 2 2.25
2
1/3 149 149 188 153
3/4 1.60 1.60 1.97 1.63
1 1.73 1.73 2.02 1.78
1 1/4 1.90 1.90 2.10 1.97
1½ 2.02 2.02 2.16 2.12
2½ 2.60 2.60 2.39 3.15
2½ 2½
3/4 1 1.74 1.74 2.32 2.67
1 1.87 1.87 2.37 2.84
1 1/4 2.04 2.04 2.45 3.09
1½ 2.16 2.16 2.51 3.29
--2 2.39 2.39 2.60 3.65
3 3
1 2.00 2.00 2.66 3.96
1 1/4 2.17 2.17 2.74 4.23
1½ 2.29 2.29 2.80 4.45
2 2.52 2.52 2.89 4.90
2½ 2.83 2.83 2.99 5.69
4
•
4
2 2.74 2.74 3.41 7.52
2½ 3.05 3.05 3.51 1 8.51
3 3.30 3.30 3.60 1 9.25
OullthngColrnectlofljflottast
U
Class 150 (Standard)
-bc A A'flTl1
COUPLING in II 1.1.
I
1/8 I 0.96 I 0.05
0.08
I IJL 0.12
1/2 1.34 0.17
3/4 1.52 0.27
1.67 0.43
1/4 1.93 0.65
1½ 2.15 0.86
r
2 2.53 1.35
L
2 1/ 2.88 2.33
3 3.18 3.36
4 3.69 5.59
0
(BRASS SEAT)in
II
j[ J
1/8 I
SPF/Anvil
1.26
Tupy
-
1IIV41
0.16 -
V4 146 1.65 023 023
1.61 1.77 0.33 0.29
½ 1.73 1.89 0.41 0.43
3/4 1.95 2.05 0.60 0.64
1 2.07 2.28 0.89 0.80
1 1/4 2.26 2.56 1.25 1.40
1 1/2 - 242 2.76 1.76 1.69
2 2.75 3.07 2.44 2.66
2 ½ 3.23 3.35 3.52 3.87
3 3.50 3.74 4.34 5.81
Class 150 (Standard)
REDUCING COUPLINGS
I
I
/7'
Size
I.
Y.i X 1/8 I
A
in
1.00
Weight
1.1.
0.07
xA 113 009
½x 0.13
3/4 X 1/4 1.44 0.20
3/4 X 1.44 0.21
I 34x½ 1.44 0.22
1xY2 1.69 0.34
1x4 1.69 0.36
1 1/4 X /2 2.06 0.47
1 ¼x 3% 2.06 0.51
1 /4X 1 2.06 0.57
1 ½x ½ 2.31 0.62
1 ½x 3/4 2.31 0.66
1 ½ x 1 2.31 0.73
1 ½ x 1 1/4 2.31 0.80
2x½ 2.81 0.94
2x 3/4 2.81 0.99
2x 1 2.81 1.03
2 x 1 1/4
- 2.81 1.17 -
2 x 1 ½ 2.81 1.25
2½x1'/4 3.25 1.81
2½x1½ 3.25 1.90
2 ½x2 3.25 2.04
3 x 1 3.69 2.48
3x1'/4 3.69 2.55
3 x 1 ½ 3.69 2.67
3 x 2 3.69 2.78
3 x 2 ½ 3.69 3.23
4 x 2 4.38 4.43
4 x 2 ½ 4.38 4.87
4 x 3 4.38 5.29
Size A
PLUGS
: c Weight
in in in in II.
Solid I 1/ I 0.44 0.28 0.38 0.04
Solid /8 0.48 0.31 0.44 0.06
Cored ½ 056 038 056 008
Cored - - ~ 0.63 0.44 0.63 0.13
Cored 1 0.75 0.50 0.81 0.20
Cored - 1 ¼ 0.80 0.56 0.94 0.32
Cored 1 ½ 0.83 0.62 1.13 0.43
Cored 2 0.88 0.68 1.31 0.67
H Cored 2 1/2 1.07 0.74 1.50 1.11
+ Cored 3 1.13 0.80 1.69 1.53
Bar Plug 4 1.22 1.00 - 2.71
Bar Plug 6 1.40 1.25 - 4.00
(~)AWIL
,ildIngC,nonThtL
Class 150 (Standard)
HEX BUSHING
in in in II I.j.
I /xV ' 0.63 0.22 ' 1.15 0.11 ' outside
1 xA 0.75 0.30 1.12 0.18 inside
inside
1 x% 0.75 0.30 1.12 0.20 inside
1 X 1/2 0.75 0.25 1.42 0.22 outside
1 x 3h 0.75 0.25 1.42 0.18 outside
1 V4 x ½ 0.80 0.34 1.34 0.32 inside
1 1/4 X 3/4 0.80 0.28 1.76 0.37 outside
1 1/4 x 1 0.80 0.28 1.76 0.30 outside
1 ½xV4 0.83 0.37 1.12 0.38 inside
1 1/2 x 3/8 0.83 0.37 1.12 0.38 inside
h/2X½ 0.83 0.37 1.34 0.40 inside
1 1 1/2 x 3/4 0.83 0.37 1.63 0.45 inside
1 1/2 x 1 0.83 0.31 2.00 0.46 outside
1 ½x 1 1/4 0.83 0.31 2.00 0.31 outside
2 x ½ 0.88 0.41 1.34 0.56 inside
/ \ 2x/4 0.88 0.41 1.63 0.61 inside
/ \ 2 x 1 0.88 0.41 1.95 0.65 inside
S + / 2 x 1 1/4 0.88 0.34 2.48 0.80 outside
\ /12 X 1 1/2 0.88 0.34 2.48 0.66 outside
2 1/2 x 3/4 1.07 0.44 1.63 0.98 inside
2 ½ x 1 1.07 0.44 1.95 1.04 inside
2 1/2 x 1 1/4 1.07 0.44 2.39 1.10 inside
2 1/2 x 1 ½ 1.07 0.44 2.68 1.38 outside
2 ½ x2 1.07 0.37 2.98 0.97 outside
3x 1 1.13 0.48 1.95 1.48 inside
3 x 1 1/4 1.13 0.48 2.39 1.57 inside
3x1½ 1.13 0.48 2.68 1.62 inside
3 x 2 1.13 0.48 3.28 2.10 outside
3 x 2 1,4 1.13 0.40 3.86 1.84 outside
3 ½ x3 1.18 0.43 4.62 2.10 outside
4x 1 1.22 0.60 1.95 2.60 inside
4x 1 1/4 1.22 0.60 2.39 2.74 inside
4x 1 ½ 1.22 0.60 2.68 2.81 inside
4 x 2 1.22 0.60 3.28 2.91 inside
4x2 1/2 1.22 0.60 3.86 2.98 inside
4 x 3 1.22 0.50 4.62 2.93 outside
'A''AYII.Iik'4IIT7flJ.(.Iii
iJ%IlI L Corporate Offices Anvil International
I N r ER N ^-r I N L 110 Corporate Drive, Suite Worldwide Customer
Service Center Building Connections That Last P.O. Box 3180
Portsmouth, NH 03802-3180 Tel: 708-885-3000
Tel: 603-422-8000 Fox: 708-534-5441
Fax: 603-422-8033
E-mail: webmaster@anvilintl.com
LUI.' REGIONAL SERVICE 1.
Eastern Region
SERVICING: Connecticut, Delaware, Florida,
Georgia, Maine, Maryland, Massachusetts, New Hampshire,
NewJersey, New York, North and South Carolina,
East Pennsylvania, Rhode Island, Vermont, Virginia
800 Malleable Road
Columbia, PA 17512
Tel: 708-534-1414
Fax: 708-534-5441
Toll Free: 1-800-301-2701
Northern Region
SERVICING: Illinois, Indianc, Iowa, Kentucky, Michigan,
Minnesota, Nebraska, North and South Dakota, Ohio,
West Pennsylvania, West Virginia, Wisconsin
750 Central Avenue II
University Park, II 60466
Tel: 708-885-3000
Fax: 708-534-5441
Toll Free: 1-800-451-2935
Southern Region
SERVICING: Alabama, Arkansas, Kansas, Louisiana,
Mississippi, Missouri, Oklabama, Tennessee, Texas
1313 Avenue R
Grand Prairie, TX 75050
Tel: 972-343-9206
Fax: 972-641-8946
Toll Free: 1-800-451-4414
Western Region
SERVICING: Alaska, Arizona, California, Colorado,
Hawaii, Idaho, Montana, Nevada, New Mexico, Oregon,
Utah, Washington, Wyomirg
1385 Greg Street
Sparks, NV 89431
Tel: 775-331-7029
Fax: 775-331-5075
Toll Free: 1-800-572-0051
BUILDING
I
CANADA SERVICE CENTERS
Anvil International Canada
Michael J. Warne, General Manager
390 Second Avenue
P.O. Box 40
Simcoe, Ontario N3Y 4K9
Tel: 519-426-4551
Fax: 519-426-5509
E-mail: mwarne@anivilintl.com
Western
5506-48 St. NW
Edmonton, Alberta, T613 2Z1
Tel: 780-413-8274
Central
390 Second Avenue
Simcoe, Ontario N3Y 4K9
Tel: 519-426-4551
Eastern
2615-25 Brabant-Marineau. (Saint-Laurent)
Montreal, Quebec, H4S 1R8
Tel: 514-745-3835
CONNECTIONS THAT
I NTERNATIONAL S AU
Europe & Middle East Region
Rick van Meesen, Sales Director
Tormentil 15
7483 BR Haaksbergen
The Netherlands
Tel: +31-53-5725570
Fax: +31-53-5725579
U.S. Customer Service
Tel: + 1-708-885-3000
Fax: +1-708-534-5441
E-mail: rvanmeesen@anvilintl.com
Mexico & Latin America
Abraham Quilada, Sales Manager
Tel: +1-281-590-4600
U.S. Customer Service
Tel: +1-708-885-3000
Fax: + 1-708-534-5441
Puerto Rico
R. R. Barril, Inc.
Tel: +1-787-982-1550
Fax: + 1-787-982-1570
U.S. Customer Service
Tel: +1-708-885-3000
Fax: + 1-708-534-5441
#622/Prinled in USA/RPI/3.07/5M/ss Coplght 2008
LAST
wiiiiiiiiii iill 0 4 EE a fl1LStar- NV1L 4rE (i' bNUIJ
www.anvilintl.com
P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org
310
RING RESTRAINER
Restraint
SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger.
MATERIAL - Carbon Steel.
FINISH - Mil. Galvanized.
LISTINGS -
cus 203-EX 2551
Listed only for use with AFCON #300 Ring Hanger.
FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the
ring hanger. To prevent upward movement of pipe that supplies a pendent
sprinkler below the ceiling.
INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions
on steel, CPVC, or copper pipe.
Snap into locking position on swivel nut of AFCON #300 Ring Hanger.
SPECIAL NOTE: When installing on CPVC sprinkler system pipe:
Verify that all assembly components are cleaned of any surface oil.
FEATURES -
* Listed only for use with AFCON #300 Ring Hanger.
ORDERING - Part # and size.
Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly.
Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems
not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not
limited to loss of business or profit, when non-AFCON products have been, or are used.
1/08
P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org
rI]
ALL THREADED ROD 10'- O' LENGTHS
ROD
SIZE
MAX. REC. LOAD LBS.
FOR SERVICE TEMP.
650°F 750°F
1/4 240 215
3/8 610 540
1/2 1130 1010
5/8 1810 1610
3/4 2710 2420
7/8 3770 3360
4960 4420
11/4 8000 7140
11/2 11630 10370
NOTE; maximum Temperature: 750°F
SIZE - 1/4 thru 1 1/2 inch rod in 10'- 0" lengths.
MATERIAL - Carbon Steel.
FINISH - Plain and E.G.,
ORDERING - Part #, rod diameter and finish.
12/10
P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org
300
RING HANGER
I thu 4 inch pipe
LISTED FOR STEELICPVC
112&314 inch pipe
5 thu 8 inch pipe
SIZE - ROD- 3/8" or 1/2"
SIZE - SYSTEM PIPE - 1/2" thru 8"
MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec.
LISTING/APPROVAL -
203-EX 25511 "- 8"
Approval guide - 1"- 8"
OSHPD OPA-0601 See Website.
CONFORMS WITH: Federal Specification WW-H-171E, Type 10.
Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10.
MAXIMUM TEMPERATURE - 650°F.
FUNCTION - Pipe hanger component of an AFCON hanger.
To support steel, CPVC or copper pipe.
INSTALLATION - Per NFPA 13,13R, 13D, these instructions and
the CPVC or copper pipe manufacturers instructions.
FEATURES -
* Sized and listed exclusively for use with #310 Surge Restrainer.
* Band edge is offset for EASY pipe insertion.
* Custom fit swivel nut for better retention in ring.
ORDERING - Part #, pipe size.
11/09
NFPA 13
PIPE ROD
1 WT. 5WTA250
UL TEST
LOAD
1 3/8 30.75 403.75 750
1114 3/8 43.95 469.75 750
1112 3/8 54.15 520.75 '750
2 3/8 76.95 634.75 750
21/2 3/8 118,35 84175 850
3 1 3/8 162.30 1061.50 1050
4 3/8 246.00 1480.00 1500
5 1/2 349.45 1996.75 2000
6 1/2 476.35 2631.75 2650
8 1/2 711.00 3805.00 4050