Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; ; AS120040; Permit11/14/24,2:07 PM AS 120040 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS120040 2525 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Lot #: 0 Reference No.: PC #: Project Title: RUE 21 T.I. Status: PENDING Applied 3/28/2012 Approved: Issued: Inspector: Applicant: A& D FIRE SPRINKLERS, INC. 2ND FLOOR 11465 WOODSIDE AVE SANTEE, CA 92071 619-448-1962 Owner: PLAZA CAM INO REAL C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940, DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees _($)j Total ($) Balance ($) 262 0 262 0 about:blank 1/1 FIRE SPRINKLERS INC. RUE 21 2525 EL CAMINO REAL, STE 161 CARLSBAD, CA 92008 FIRE SPRINKLER SUBMITTAL MANUFACTURER'S DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. ttlCa /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series 7V-FRB - 2.8, 4.2, 5. 6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendert position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up :0 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of coppEr alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkle.- system or its compo- nents and cause the sprinkler to fail to operate 'n a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1I3I - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT 1Y2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT 1Y3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.0K, 314"NPT TY4231 - Pendent 8.01K, 314"NPT Page 1 of 10 APRIL, 2006 TFPI7I SSP DEFLECTOR* ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2" ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON NPT i 2-7/8" (73,0 mm) DIA. ssU * DEFLECTOR 7/16" (11,1 mm) I NOMINAL I MAKE-IN I 2-3/16" WRENCH (55,6 mm) FLATS 1/2" NPT** 'RENCH. FLATS Page 2 of 10 TFPI7I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression 7- Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) 7/16" (11,1 mm) STYLE 10or20 NOMINAL RECESSED ,, MAKE-IN ESCUTCHEON SSU * DEFLECTOR LN NOMINAL i, 4 SSP DEFLECTOR* h — 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 7/16" (11,1 mm) STYLE 10or2( NOMINAL RECESSED MAKE-IN ESCUTCHEOI 2-7/8" (73,0 mm) DIA. SSP DEFLECTOR* ESCUTCHEON PLATE SEATING SURFACE T_ 2-3/16" Al (55,6 mm) (38, !II i]II'1.I 7/1 NOMINAL 'JH 4 ESCUTCHEON 1/2(12,7mm) STYLE 30 0r40 PLATE SEATING ** NOMINAL 3/4 RECESSED SURFACE MAKE-IN ESCUTCHEON NPT 2-5/16" (58,7 mm) 1-9/16" W (39,7 mm) WRENCH FLATS '1 SSP DEFLECTOR*2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT SSU * DEFLECTOR 6* 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) 3 3/4 NPT** UPRIGHT CROSS SECTION TFPI7I Page 3 of 10 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4 of 10 TFPI7I K TYPE TEMP. BULB LIQUID NATURAL BRASS SPRINKLER FINISH (S" POLYESTER I CHROME PLATED 2.8 PENDENT (TY1231) and UPRIGHT (TYI13I) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286°F/141°C Blue 1/2" NPT 135°F/57C Orange 1, 2, 5 RECESSED PENDENT (TY1231) Figure 5 155F/68°C Red 175°F/79C Yellow 2O0FI93°C Green RECESSED PENDENT (TY1231)** Figure 6 135°F/57°C Orange 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135F/57*C Orange 1,2 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 7 135°F157°C Orange 155°F168oC Red 175°F179°C Yellow 200F/93C Green RECESSED PENDENT (TY2231)** Figure 8 135°F/57°C Orange 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/psi112 (60,5 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/barll2) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED FWHITE T *" LYESER LEAD COATED 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2,3,4,5,6,7 1,2,3,5 155F/68C Red 175°F/79C Yellow 200F/93C Green 286°F/141C Blue 1/2' NPT 135°F/57°C Orange 1,24,5 N/A RECESSED PENDENT (TY3231)* Figure 9 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 135°F/57°C Orange 1,2,3,4,5 I I I I 1,2,4,5 I Green N/A RECESSED PENDENT (TY3231)** Figure 10 155F/68°C Red 175F/79°C Yellow 200°F/93°C 8.0 PENDENT (1Y4231) and UPRIGHT (TY4131) 135F/57C Orange 1,2, 3,4,5,6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141C Blue 3/4' NPT RECESSED PENDENT (TY4231)* Figure 11 135°F/57°C Green 1, 2, 4, 5 N/A 155°F/68C Orange 175FI79°C Red 200°F/93C Yellow RECESSED PENDENT (TY4231)** Figure 12 135°F/57°C Orange 1,2,3,4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD BRASS PLATED POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2 RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4,, RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and ,the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286 °F/14 1°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 21 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I - 2-718' DIA. - 5/8±114" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) _ 2-1/4" DIA. 114' (6,4 mm) FACE OF MOUNTING SPRINKLER PLATE I FITTING I 1/8" I (3,2 mm) MOUNTING CLOSURE SERIES 1-5/16' (33,3 mm) SURFACE TY-FRB 13/16"(20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. - 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4mm) _ 2-1/4' DIA. 1/4"(6,4 mm) I FACE OF MOUNTING SPRINKLER I PLATE FITTING 1/8' (3,2 MM) '1 F MOUNTING SURFACE SERIES 1-114'(31,8 mm)f CLOSURE TYFRB 3/4"(19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 7 of 10 - 2-7/8" DIA. (73,0 mm) 1/2±1/8' 1/2"(12,7 mm) E (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I SPRINKLER PLATE FACE OF [572mm) -1 MOUNTING FITTING 'I _______________ 1/8' M(3,2 mm) MOUNTING / I16" /1 SURFACE/f (33,3 mm) CLOSURE SERIES TY-FRB 1-1/16"(27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2"(12,7 mm) E (12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I I SPRINKLER PLATE FACE OF 1Z57,2 mm) MOUNTING I FITTING 1/8' I ______ MOUNTING SURFACE SERIES l-l/4'(31,8mm) CLOSURE TYFRB 1"(25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random Page 8 of 10 2-718" DIA. - 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) I FACE OF MOUNTING SPRINKLER PLATE I FITTING 1/8' (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 j 711~~ I CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. _ I (73,0 mm) 2-1/4" DIA. 3/4"(19,1 mm) 1/4"(6,4 mm) (57,2 mm) MOUNTING 1/8" (3,2 mm) t 1-5/16" (33,3 mm)t 13/16(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) SPRINKLEqR PLATE FACE OF 572 mm) MOUNTING FITTING 1/8" I SURFACE (32mm) IMOUNTIN CLOSURE SERIES 1-1/4(31,8 mm) TYFRB 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-718"DIA. 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) r (12,7±3,2 mm) - 2-1/4" DIA. 1/4"(6,4 mm) I FACE OF (57.2 MM) MOUNTING I SPRINKLER PLATE I FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-FRB sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 9 of 10 P/N 57-XXX-X-XXX MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) 1Y1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 I I I SPRINKLER [ I NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED I 135 155 175 200 286 TEMPERATURE RATING 155*F/68*C 175°F179°C 2000F/93*C 286°F/141°C * Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 10 of 10 TFPI7I TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 p1 ulini Im J.'A wor, iiiii APML9tar M&NVIL 4 NEW. (' ' Anvil's Unmatched Piping Products for Every Industry Anvil provides the most comprehensive line of innovative, durable, and reliable pipe connections, support systems, and customer service. For more than 150 years, Anvil has provided integrated, reliable piping solutions for a variety of applications. With the most complete line of piping products, expert design services, and a responsive customer service team, Anvil's total package is unmatched throughout the industry. Our professionals will work with you to develop innovative solutions that meet your demands and exceed your expectations. From HYAC, plumbing and mechanical to fire protection, mining, oil and gas, and gas utilities, Anvil covers all markets. Our extensive product line includes grooved couplings, fittings, and valves; cast and malleable pipe fittings; forged steel fittings and unions; steel pipe nipples and couplings; pipe hangers and supports; strut and channel; oil country fittings; and valves. Our exceptional market-specific expertise ensures you always get the best solution for your unique application. In addition to Anvil's extensive line of domestically manufacture products, Anvil also offers a full line of Globally manufactured malleable iron fittings and steel pipe nipples. These products are manufactured within ISO 9001:2000 facilities where Anvil's quality control engineers oversee the entire process. Anvil is committed to providing the finest quality pipe fittings available, which we believe only a true manufacturer can provide. Engineered drawings of fittings andnipples along with detailed inspection procedures, leave no questions regarding Anvil's commitment to quality imported products. With 150 years of manufacturing expertise, Anvil is in a unique position to set the highest quality standard for both domestic and import products. Anvil's specifications for SPF malleable fittings and pipe nipples are higher than typical ANSI specification. The SPF malleable fittings are UL Listed and FM Approved. Building Con,e,,Th,tL,. Standard Welded Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured product requirements. Dimensional: I ASTM A733 Material: } ASTM A53 Type F or Type E Galvanizing: I Hot Dip Galvanizing Threading:88 I ASME B 1.20.1 Standard End Finish Tapered Pipe Thread (NPT) 8Gclvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. "British Standard threading per BS 21 available upon request. Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the outside at an angle of 35' +1- 10' to the cemral axis. Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends. Also available: Ready Cut Pipe, Standard - Schd. 40 (black and galvanized) Pipe Size: 1/2,3/4, 1", 11/4 , 11/2 , 2" Pipe Length: 8", 24", 3011, 4811, 60", 72" "66" Packs, Standard - Schd. 40 (black and galvanized) Nipple Size: '/2", 3/4', 1, 11/4 , 11/2 , 2" Single Run Nipple Packs (black and galvanized) Pipe Size: '/2", 3/4, 1, 11/4", 1V2, 2" I 1/8 ' .405 I 3/4 1 1 /2 2 '2'/2 ' Ti1Nipple 3 '3'/2' 4 '4'/2' and 5 '5'/2' 6 ' 7 ' 8 ' 9 10 11 ' 12' 1/ .540 7/8 1 1/2 221/2 331/2 441/2 55 1/2 6 789101112 .675 1 1/2 2 2'/2 3 3'/2 4 41/2 5 51/2 6 7 8 9 10 11 12 1/2 .840 1 1/8 1 /2 2 21/2 3 3'/2 4 4 1/2 5 51/2 6 7 8 9 10 11 12 3/4 1.050 1 /8 11/2 2 2'/2 3 3 1/2 4 1 4 1/3 5 5'/2 6 7 8 9 10 11 12 1 1.315 1 1/2 2 2'/2 3 3 1/2 4 41/2 5 51/3 6 7 89 10 11 12 1 1/4 1.660 1 /8 2 2 '/2 3 31/2 4 41/2 5 5 /2 6 7 8 9 10 11 12 1 '/2 1.900 1/4 2 2'/2 3 3'/2 4 41/2 5 5 72 6 7 8 9 10 11 12 2 2.375 2 2'/2 3 31/2 4 41/2 5 5'/2 6 7 8 9 10 11 12 2'/2 2.875 2 1/2 3 3'/2 4 4'/2 5 51/3 6 7 8 9 10 11 12 3 3.500 2/8 3 3'/2 4 4 /2 5 5'/2 6 7 8 9 10 11 12 4 4500 - 2 /8 4 4 5 5 1/ 6 7 8 9 10 11 12 6 6.625 3 /8 4 4 '/2 5 5 '/2 6 7 8 9 10 11 12 AWIL &dMlngC•,,,ThtL Extra Heavy - SCH. 80 Welded Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured product requirements. Dimensional: I ASTM A733 Material: I ASTM A53 Type F or Type E Galvanizing: I Hot Dip Galvanizing* Threading: I ASME B 1.20.1 Standard End Finish Tapered Pipe Thread (NPT) *Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the outside at an angle of 35 +1- 10 to the central axis. Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends. Pipe Size O.D. 18 Pipe Length Close .405 3/4 1 1/2 2 2 /2 Pipe 3 Nipple Lengths 3 l/ 4 4 1/2 5 (Black 5 1/ and galvanized) 6 7 8 9 10 11 12 1/4 .540 7/ 1 1/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 .675 1 1 1/2 2 21/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12 1/3 - .840 1 1/8__- 1 1/2 2 21/2 3 31/3 4 41/2 5 51/3 6 7 8 9 10 11 12 3/4 1.050 1 /8 1 1/3 2 21/2 3 31/2 4 41/2 5 51/3 6 7 8 9 10 11 12 P 1 1.315 1 1/2 2 21/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12 1 1/4 1.660 1 5/8 2 2/2 3 31/2 4 4 1/2 5 51/2 6 7 8 9 10 11 12 1 1/2 1.900 1/4 2 1 21/2 3 31/3 4 1 4 1/2 5 51/2 6 7 8 9 10 11 12 2 2375 2 21/2 3 372 4 41/2 5 5'/2 1 6 7 8 9 1 10 11 12 21/2 2.875 21/2 3 1 372 4 41/2 5 51/2 6 7 8 1 9 10 111 12 3 3.500 2/ 3 3 '/2 4 4 '/2 5 51/ 6 7 8 9 10 11 12 3 1/2 - 4.000 2/4 4 4 1h 5 51/2 6 7 8 9 10 11 12 4 4.500 2/e 4 41/2 5 51/2 6 7 8 9 10 11 12 5 1 5.563 1 3 - - - 4 1 41/ 5 1 5 1/2 6 1 7 8 9 10 11 12 6 6.625 1 3 1/8 4 1 4 1/2 5 51/2 6 1 7 8 9 10 11 12 Building Connetgo.0 That I45t Extra Heavy Seamless Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured product requirements. Dimensional: I ASTM A733 Material: I ASTM Al 06 Grade B Galvanizing: I Hot Dip Galvanizing* Threading: I ASME B 1.20.1 Standard End Finish Tapered Pipe Thread (NPT) *Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the outside at an angle of 350 +1- 10° to the central axis. Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends. Pipe Pipe Size O.D. I 1/8 .405 Length Close gp 3/4 1 1/2 2 21/2 Pipe 3 Nipple 3 /2 4 Lengths I 41/3 (Black I I 5 5 1/2 and galvanized) I I 6 7 8 I I 9 10 I 11 12 1/4 .540 /8 1 1/2 2 2'/2 3 312 4 41/2 5 51/2 6 7 8 9 10 11 12 .675 1 1 1/2 2 21/2 3 31/2 4 472 5 51/2 6 7 8 9 10 11 12 1/2 1 .840 118 1 1/2 1 2 21/2 3 3 72 4 41/2 5 51/3 6 7 8 9 10 11 12 3/4 1.050 1 /8 11/2 2 21/2 3 31/2 4 41/2 5 572 6 7 8 9 10 11 12 1 1.315 1 1/2 2 21/2 3 31/3 4 41/2 5 51/2 6 78 9 10 11 12 ]1/4 1.660 1 5/ 2 272 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 1 1/2 1.900 1/4 2 2'I2 3 31/2 4 41/2 5 5'/2 6 7 8 9 10 11 12 2 2.375 2 2 1/2 3 31/ 4 4'/2 5 51/2 6 7 8 9 10 11 12 2 1/2 2.875 2 1/2 3 3 1/2 4 41/2 5 51/2 6 7 8 9 10 11 12 3 E..500 2/s 3 3 '/2 4 41/3 5 51/2 6 7 8 9 10 11 12 4 &500 2/s 4 41/a 5 51/2 6 7 8 9 10 11 1 12 5 5.563 3 41/2 5 51/2 6 7 8 9 10 11 12 6 6.625 31A 4 1/2 5 5 6 1 7 8 9 10 11 12 AWIL .dIdingCon0.00n0Th0tL00t Class 150 (Standard) STANDARDS ISPECIFICATIONS IImport iI!lMalleableIron IScrewed •fflFY3(l(ClassF15I0) Dimensional: Fittings: Unions: Bushings/Plugs: ASME B16.3 ASME B 16.39 ASME B 16.14 Material: i ASTMA-197 Galvanizing: ASTMA-153 (Hot Dip Galvanizing) Threading:* ASME B 1.20.1 Pressure Rating: Unions: - Bushings/Plugs: B 16.3 ASME B 16.39 ASME B 16.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. - - Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. British Standard threading per BS 21 available upon request. 900 REDUCING ELBOW in 1/4 X /8 I. 0.74 '1TIfl I. I.,. 0.76 0.08 1 • B ---a -I - f I • %x¼ 0.81 0.85 0.11 0.88 0.90 0.13 097 - 098 016 /2X 3/8 1.04 1.03 0.19 1.12 1.13 0.26 /4x½ 1.20 1.22 - 0.29 1 X 1/2 1.26 1.36 0.42 1 x 3/4 1.37 1.45 0.47 1 ¼ X 1/2 1.34 1.53 0.54 1 1/4 x 3/4 1.45 1.62 0.62 1 ¼x 1 1.58 1.67 0.73 - - 1 1/2 X 1 -- 1.65 1.80 0.88 1 V2x 1 1/4 1.82 1.88 1.03 2x 3/4 1.60 1.97 1.04 2 x 1 1.73 2.02 1.28 2 x 1 14 1.90 2.10 1.36 2x1V2 202 - 216 151 - - 2'/2x1 ½ 2.16 2.51 2.20 2 1/2 x 2 2.39 2.60 2.55 3 x 2 2.52 2.89 3.35 3x2 1/2 2.83 2.99 4.12 4 x 3 - - 3.30 3.60 6.65 -. www.anvilinti.com AWIL 0dWh,gCo,,*n. Class 150 (Standard) 900 ELBOW 1fr4. I. 1/8 A I. 0.69 'ATtt11 I.;. 0.06 ¼ 0.81 0.10 0.95 0.15 ½ 1.12 0.22 - 3/4 1.31 0.36 1 1.50 0.57 1¼ 1.75 0.87 - 1½ -- 1.94 1.16 2 2.25 1.81 2½ 2.70 3.23 3 3.08 4.82 4 3.79 8.41 6 5.13 19.96 450 ELBOW ifr4 - I. A II Weight 1.1. I I 1/8 I 0.63 0.06 ¼ 0.73 0.11 -' 0.80 0.14 ½ 088 0.20 3/4 0.98 0.32 1 1.12 0.50 1 1h 1.29 0.76 1 1/ 1.43 1.00 2 1.68 1.61 2 - -- 195 2.77 rJr(_'2 3 2.17 4.03 1 4 2.61 6.92 6 3.46 16.31 AWIL Build/nc Coflntctito.S That Lost Class 150 (Standard) jfr4. 90° STREET ELBOW in II II 1.7. 1/8 0.69 1.00 0.05 1/4 0.81 1.19 0.09 *i''1ll1ilhi /8 0.95 1.44 0.15 ½ 112 163 020 3/4 1.31 1.89 0.34 1 1.50 2.14 0.58 1 1/4 1.75 2.45 0.84 - 1 ½ 1.94 2.69 1.12 2 2.25 3.26 1.85 2½ 2.70 3.86 3.28 3 3.08 4.51 5.00 4 3.79 5.69 9.18 45° STREET ELBOW 1L.L .1 .1fr4. in ½ in 0.63 in 0.83 1.7. 0.05 1/ 0.73 0.94 0.08 % - 0.80 1.03 0.12 ½ 0.88 1.15 0.18 '/4 0.98 1.29 0.27 1 1.12 1.47 0.44 1 ¼ 1.29 1.71 0.70 1 1/2 143 188 092 2 1.68 2.22 1.50 Size A Weight CROSS in II I.j. /4 0.81 0.17 1) /8 0.95 0.26 I_ 1/2 1.12 0.38 A A 3/4 1.31 0.61 - A 1 1.50 0.95 ---H--- 1 1/4 1.75 1.42 - A 1 1/2 1.94 1.86 2 2.25 2.83 8 www.anviIintl.com Class 150 (Standard) CAP 1 j. Size in 1/8 A It 0.53 Weight I.j. 0.03 1/4 063 005 - 3/ 0.74 0.07 1/2 0.87 0.11 1.16 0.30 1 1/4 1.28 0.44 1 1/ 1.33 0.55 2½ 1.70 1.49 3 1.80 2.20 3 ½ - 1.90 3.02 4 2.08 3.79 6 255 - 877 TEE -7 I FI-4 JLJ [j II I 1/8 Size TATLTI II 0.69 I I.;. 0.09 Y4 0.81 0.14 0.95 0.21 1/2 0.31 -: 0.50 0.79 1 1/4 1.75 1.19 1 ½ 1.94 - 1.57 2.25 2.43 -2 2 ½ 2.70 4.33 3 3.08 6.37 4 3.79 11.03 AWIL 8,llthflgCe,n,Mown Class 150 (Standard) REDUCING TEE I. II II in lbs 1/4 0.97 0.97 0.98 0.24 1.04 1.04 1.03 027 1/2 1/2 : 0.37 0.49 ½ 1.20 1.12 1.22 0.38 1/2 3/4 1.31 1.22 131 045 - 1/4 1.05 1.05 1.08 0.36 %1.12 1.12 1.13 0.39 3/4 1/2 1.20 1.20 1.22 0.43 - 1 1.45 1.45 137 0.62 1/4 1 1.50 1.18 1.50 0.63 ½ 1.26 1.12 1.36 0.48 1/2 3/4 1.37 1.22 1.45 0.56 1 150 136 150 067 ½ 1.26 1.20 1.36 0.53 3/4 3/4 1.37 131 1.45 0.61 1 O .62 1.45 1 1/4 1.67 1.67 1.58 0.94 1 ½ 1.80 1.80 1.65 1.07 2 2.02 2.02 1.73 1.45 1 1.58 1.36 1.67 0.82 ½ 1 1/4 1.75 1.53 1.75 0.95 3/4 1.45 1.31 1.62 0.75 3/4 1 1.58 1.45 1.67 0.87 1 1/4 - 1.75 1.62 1.75 1.00 ½ 1.34 1.26 1.53 0.74 3/4 1.45 1.37 1.62 0.82 1'/4 1 1 1.58 1.50 1.67 0.94 11/4 1.75 1.67 1.75 1.08 ½ 1.34 1.34 1.53 0.84 3/4 1.45 145 1.62 0.92 1 1/4 1 1.58 1.58 1.67 1.04 CONTINUED 1½ - 1.88 1.88 1.82 1.34 ON NEXT PAGE. 2 2.10 2.10 1.90 1.65 t,il&ng ConnectSn, That inn Class 150 (Standard) REDUCING TEE I • II I '? C I 1 ½ 1tI'4- II 1/2 1 ½ I. 1.94 in 1.66 II 1.94 Ibs 1.24 1.50 1.26 1.69 0.86 1½ 1.94 1.94 1.29 - 1 1 1/4 1.82 1.67 1.88 1.23 1½ 194 1.80 1.94 1.35 1 1/4 3/4 1.52 1.45 1.75 1.04 1 1.65 1.58 1.80 -1.17 -- 1 1/4 1.82 1.75 1.88 1.32 1 1/2 1.94 1.88 1.94 1.45 1 ½ ½ 1.41 1.41 1.66 1.04 1.52 1.52 1.75 1.14 1 1 1.5 1.65 1.80 1.27 1 1/4 182 182 188 143 2 2.16 2.16 2.02 1.89 1.89 2 /2 2 2.25 1.88 225 3/4 2 2.25 1.97 2.25 1.93 1 2 225 202 - 225 200' 1 1/4 1 1/4 1.90 1.75 2.10 1.64 1½ 2.02 1.88 - flo 1.80 2 2.25 2.10 2.25 2.09 1½ 1 1.73 165 2.02 157 1 1/4 1.90 1.82 2.10 1.71 77 1½ 2.02 2.25 2.16 1.94216 1.88 -- 2.21 2 2.25 2 1/3 149 149 188 153 3/4 1.60 1.60 1.97 1.63 1 1.73 1.73 2.02 1.78 1 1/4 1.90 1.90 2.10 1.97 1½ 2.02 2.02 2.16 2.12 2½ 2.60 2.60 2.39 3.15 2½ 2½ 3/4 1 1.74 1.74 2.32 2.67 1 1.87 1.87 2.37 2.84 1 1/4 2.04 2.04 2.45 3.09 1½ 2.16 2.16 2.51 3.29 --2 2.39 2.39 2.60 3.65 3 3 1 2.00 2.00 2.66 3.96 1 1/4 2.17 2.17 2.74 4.23 1½ 2.29 2.29 2.80 4.45 2 2.52 2.52 2.89 4.90 2½ 2.83 2.83 2.99 5.69 4 • 4 2 2.74 2.74 3.41 7.52 2½ 3.05 3.05 3.51 1 8.51 3 3.30 3.30 3.60 1 9.25 OullthngColrnectlofljflottast U Class 150 (Standard) -bc A A'flTl1 COUPLING in II 1.1. I 1/8 I 0.96 I 0.05 0.08 I IJL 0.12 1/2 1.34 0.17 3/4 1.52 0.27 1.67 0.43 1/4 1.93 0.65 1½ 2.15 0.86 r 2 2.53 1.35 L 2 1/ 2.88 2.33 3 3.18 3.36 4 3.69 5.59 0 (BRASS SEAT)in II j[ J 1/8 I SPF/Anvil 1.26 Tupy - 1IIV41 0.16 - V4 146 1.65 023 023 1.61 1.77 0.33 0.29 ½ 1.73 1.89 0.41 0.43 3/4 1.95 2.05 0.60 0.64 1 2.07 2.28 0.89 0.80 1 1/4 2.26 2.56 1.25 1.40 1 1/2 - 242 2.76 1.76 1.69 2 2.75 3.07 2.44 2.66 2 ½ 3.23 3.35 3.52 3.87 3 3.50 3.74 4.34 5.81 Class 150 (Standard) REDUCING COUPLINGS I I /7' Size I. Y.i X 1/8 I A in 1.00 Weight 1.1. 0.07 xA 113 009 ½x 0.13 3/4 X 1/4 1.44 0.20 3/4 X 1.44 0.21 I 34x½ 1.44 0.22 1xY2 1.69 0.34 1x4 1.69 0.36 1 1/4 X /2 2.06 0.47 1 ¼x 3% 2.06 0.51 1 /4X 1 2.06 0.57 1 ½x ½ 2.31 0.62 1 ½x 3/4 2.31 0.66 1 ½ x 1 2.31 0.73 1 ½ x 1 1/4 2.31 0.80 2x½ 2.81 0.94 2x 3/4 2.81 0.99 2x 1 2.81 1.03 2 x 1 1/4 - 2.81 1.17 - 2 x 1 ½ 2.81 1.25 2½x1'/4 3.25 1.81 2½x1½ 3.25 1.90 2 ½x2 3.25 2.04 3 x 1 3.69 2.48 3x1'/4 3.69 2.55 3 x 1 ½ 3.69 2.67 3 x 2 3.69 2.78 3 x 2 ½ 3.69 3.23 4 x 2 4.38 4.43 4 x 2 ½ 4.38 4.87 4 x 3 4.38 5.29 Size A PLUGS : c Weight in in in in II. Solid I 1/ I 0.44 0.28 0.38 0.04 Solid /8 0.48 0.31 0.44 0.06 Cored ½ 056 038 056 008 Cored - - ~ 0.63 0.44 0.63 0.13 Cored 1 0.75 0.50 0.81 0.20 Cored - 1 ¼ 0.80 0.56 0.94 0.32 Cored 1 ½ 0.83 0.62 1.13 0.43 Cored 2 0.88 0.68 1.31 0.67 H Cored 2 1/2 1.07 0.74 1.50 1.11 + Cored 3 1.13 0.80 1.69 1.53 Bar Plug 4 1.22 1.00 - 2.71 Bar Plug 6 1.40 1.25 - 4.00 (~)AWIL ,ildIngC,nonThtL Class 150 (Standard) HEX BUSHING in in in II I.j. I /xV ' 0.63 0.22 ' 1.15 0.11 ' outside 1 xA 0.75 0.30 1.12 0.18 inside inside 1 x% 0.75 0.30 1.12 0.20 inside 1 X 1/2 0.75 0.25 1.42 0.22 outside 1 x 3h 0.75 0.25 1.42 0.18 outside 1 V4 x ½ 0.80 0.34 1.34 0.32 inside 1 1/4 X 3/4 0.80 0.28 1.76 0.37 outside 1 1/4 x 1 0.80 0.28 1.76 0.30 outside 1 ½xV4 0.83 0.37 1.12 0.38 inside 1 1/2 x 3/8 0.83 0.37 1.12 0.38 inside h/2X½ 0.83 0.37 1.34 0.40 inside 1 1 1/2 x 3/4 0.83 0.37 1.63 0.45 inside 1 1/2 x 1 0.83 0.31 2.00 0.46 outside 1 ½x 1 1/4 0.83 0.31 2.00 0.31 outside 2 x ½ 0.88 0.41 1.34 0.56 inside / \ 2x/4 0.88 0.41 1.63 0.61 inside / \ 2 x 1 0.88 0.41 1.95 0.65 inside S + / 2 x 1 1/4 0.88 0.34 2.48 0.80 outside \ /12 X 1 1/2 0.88 0.34 2.48 0.66 outside 2 1/2 x 3/4 1.07 0.44 1.63 0.98 inside 2 ½ x 1 1.07 0.44 1.95 1.04 inside 2 1/2 x 1 1/4 1.07 0.44 2.39 1.10 inside 2 1/2 x 1 ½ 1.07 0.44 2.68 1.38 outside 2 ½ x2 1.07 0.37 2.98 0.97 outside 3x 1 1.13 0.48 1.95 1.48 inside 3 x 1 1/4 1.13 0.48 2.39 1.57 inside 3x1½ 1.13 0.48 2.68 1.62 inside 3 x 2 1.13 0.48 3.28 2.10 outside 3 x 2 1,4 1.13 0.40 3.86 1.84 outside 3 ½ x3 1.18 0.43 4.62 2.10 outside 4x 1 1.22 0.60 1.95 2.60 inside 4x 1 1/4 1.22 0.60 2.39 2.74 inside 4x 1 ½ 1.22 0.60 2.68 2.81 inside 4 x 2 1.22 0.60 3.28 2.91 inside 4x2 1/2 1.22 0.60 3.86 2.98 inside 4 x 3 1.22 0.50 4.62 2.93 outside 'A''AYII.Iik'4IIT7flJ.(.Iii iJ%IlI L Corporate Offices Anvil International I N r ER N ^-r I N L 110 Corporate Drive, Suite Worldwide Customer Service Center Building Connections That Last P.O. Box 3180 Portsmouth, NH 03802-3180 Tel: 708-885-3000 Tel: 603-422-8000 Fox: 708-534-5441 Fax: 603-422-8033 E-mail: webmaster@anvilintl.com LUI.' REGIONAL SERVICE 1. Eastern Region SERVICING: Connecticut, Delaware, Florida, Georgia, Maine, Maryland, Massachusetts, New Hampshire, NewJersey, New York, North and South Carolina, East Pennsylvania, Rhode Island, Vermont, Virginia 800 Malleable Road Columbia, PA 17512 Tel: 708-534-1414 Fax: 708-534-5441 Toll Free: 1-800-301-2701 Northern Region SERVICING: Illinois, Indianc, Iowa, Kentucky, Michigan, Minnesota, Nebraska, North and South Dakota, Ohio, West Pennsylvania, West Virginia, Wisconsin 750 Central Avenue II University Park, II 60466 Tel: 708-885-3000 Fax: 708-534-5441 Toll Free: 1-800-451-2935 Southern Region SERVICING: Alabama, Arkansas, Kansas, Louisiana, Mississippi, Missouri, Oklabama, Tennessee, Texas 1313 Avenue R Grand Prairie, TX 75050 Tel: 972-343-9206 Fax: 972-641-8946 Toll Free: 1-800-451-4414 Western Region SERVICING: Alaska, Arizona, California, Colorado, Hawaii, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, Wyomirg 1385 Greg Street Sparks, NV 89431 Tel: 775-331-7029 Fax: 775-331-5075 Toll Free: 1-800-572-0051 BUILDING I CANADA SERVICE CENTERS Anvil International Canada Michael J. Warne, General Manager 390 Second Avenue P.O. Box 40 Simcoe, Ontario N3Y 4K9 Tel: 519-426-4551 Fax: 519-426-5509 E-mail: mwarne@anivilintl.com Western 5506-48 St. NW Edmonton, Alberta, T613 2Z1 Tel: 780-413-8274 Central 390 Second Avenue Simcoe, Ontario N3Y 4K9 Tel: 519-426-4551 Eastern 2615-25 Brabant-Marineau. (Saint-Laurent) Montreal, Quebec, H4S 1R8 Tel: 514-745-3835 CONNECTIONS THAT I NTERNATIONAL S AU Europe & Middle East Region Rick van Meesen, Sales Director Tormentil 15 7483 BR Haaksbergen The Netherlands Tel: +31-53-5725570 Fax: +31-53-5725579 U.S. Customer Service Tel: + 1-708-885-3000 Fax: +1-708-534-5441 E-mail: rvanmeesen@anvilintl.com Mexico & Latin America Abraham Quilada, Sales Manager Tel: +1-281-590-4600 U.S. Customer Service Tel: +1-708-885-3000 Fax: + 1-708-534-5441 Puerto Rico R. R. Barril, Inc. Tel: +1-787-982-1550 Fax: + 1-787-982-1570 U.S. Customer Service Tel: +1-708-885-3000 Fax: + 1-708-534-5441 #622/Prinled in USA/RPI/3.07/5M/ss Coplght 2008 LAST wiiiiiiiiii iill 0 4 EE a fl1LStar- NV1L 4rE (i' bNUIJ www.anvilintl.com P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - cus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org rI] ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 4960 4420 11/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru 1 1/2 inch rod in 10'- 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain and E.G., ORDERING - Part #, rod diameter and finish. 12/10 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thu 4 inch pipe LISTED FOR STEELICPVC 112&314 inch pipe 5 thu 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 25511 "- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13,13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD 1 WT. 5WTA250 UL TEST LOAD 1 3/8 30.75 403.75 750 1114 3/8 43.95 469.75 750 1112 3/8 54.15 520.75 '750 2 3/8 76.95 634.75 750 21/2 3/8 118,35 84175 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050