HomeMy WebLinkAbout1305 LAUREL TREE LN; 162; CBRA2024-0042; PermitBuilding Permit Finaled
(cityof
Carlsbad
Residential Associated Permit
Print Date: 07/15/2025
Job Address: 1305 LAUREL TREE LN, # 162, CARLSBAD, CA 92011-1 279
Permit Type: BLDG-Associated Permit Residential Work Class: Alteration
Parcel#: 2120405900 Track#:
Valuation: $10,000.00 Lot#:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check #:C,,43C.,'2ffl-'-i • orJ<d,
Description: LAUREL TREE APARTMENTS: ACCESSIBILITY UPGRADES// UNIT TYPE Al
Applicant:
SAN DIEGO PERMIT CO INC
IAN HARRIS
PO BOX 124979
SAN DIEGO, CA 92112-4979
FEE
REMODEL-RESIDENTIAL -KITCHEN or BATH
Property Owner:
CARLSBAD LAUREL TREE APARTMENTS LP
1355 3RD AVE
CARLSBAD, CA 91911
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -RESIDENTIAL (SMIP)
Total Fees: $403.30 Total Payments To Date: $403.30
Building Division
Permit No:
Status:
CBRA2024-0042
Closed -Finaled
Applied: 04/03/2024
Issued: 06/21/2024
Finaled Close Out: 07/15/2025
Final Inspection: 05/20/2025
INSPECTOR: Kersch, Tim
CoApplicant:
MAAC PROJECT
RACHEL LOADER
1355 THIRD AVE
CHULA VISTA, CA 91911-4302
(619) 799-9080
Balance Due:
AMOUNT
$401.00
$1.00
$1.30
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
Building Permit Inspection History Finaled
(cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBRA2024-0042)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 04/03/2024 Owner: CARLSBAD LAUREL TREE
APARTMENTS LP
Work Class: Alteration Issue Date: 06/21/2024 Subdivision: PARCEL MAP NO 15661
Status: Closed -Finaled Expiration Date: 11/03/2025 Address: 1305 LAUREL TREE LN, # 162
IVR Number: 55646 CARLSBAD, CA 92011-1279
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
05/06/2025 05/06/2025 BLDG-84 Rough 283972-2025 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLDG-SW-Inspection 284215-2025 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
05/20/2025 05/20/2025 BLDG-Final Inspection 285343-2025 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, July 15, 2025 Page 1 of 1