Loading...
HomeMy WebLinkAbout2158 VISTA LA NISA; ; CB982774; Permitv5o3 5 olf{p 09/04/98 09:04 Page 1 of 1 B U I L D I N G P E R M I T Permit No: CB982774 Project No: A9803628 Development No: DEV89110 Job Address : 2158 VISTA LA NISA Suite: Permit Type: SINGLE FAMILY DWLNG -DETACHED Parcel No: 255-262-15-00 Lot#: 202 Valuation: 290,343 Construction Type: VN Occupancy Group: Reference#: CT 88-03 Status: Description: 3356 SF+648 GAR+34 SF PORCH Applied : : PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD Apr/Issue: Entered By: 619 292-2200 ISSUED 04/17/98 09/04/98 RMA Appl/Ownr : STANDARD PACIFIC 9 3 3 5 CHESAPEA.KE DR SAN DIEGO CA 92123 Plan Check Numbers > ORIG 0809 09/04/98 0001 01 97 3162 PCK 982518 C-PRHT 02 12844-32 *** Fees Required *** *** Fees: 12,844.32 Adjustments: . 00 Total Fees: Fees Collected & Credits Tot a l Credits: Total Pa yments : Ba l ance Due: .00 .00 12,844.32 *** Fee description Units Fee/Unit Ext fee Data Number of Bedrooms ) 5 Number of Bathrooms . > 4.50 Building Permit Plan Check ~ / Strong Motion Fee Enter Plan Check @is (Un~ Amt v 67 .00 Enter "Y" to Au to ale P. F . I\ > Enter "Y" to Autoc le T.I ,P. > Payoff Fee for CFD > 4254 .32 Enter LFM Fee (Zones=6,11,1 2) > 310.00 Enter "Y" for Plumbing I ssu.e Fee > Each Plumbing Fixture or Trap > 20 Each Building Sewer > 1 Each Install/Repair Water Li n e ~ 1 Each Water Heater and/or V~nt > 1 Gas Piping System > 1 Each Vacuum Breaker > 2 Enter "Y" for Electric Issue Fee > Single Phase Per AMP > 200 Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > 1 Each Install Fireplace > 2 Each Exhaust Fan > 6 Each Install/Reloc Vent > 2 CITY OF CARLSBAD 7 I J -1.00 7 .00 15 .00 7.00 7.00 7.00 7.00 .25 9.00 6 .50 6.50 4.50 5 .00 4.50 1290.00 839.00 29.00 -67 .00 5284 .00 Y 550 .00 Y 4254.32 310.00 20.00 Y 140.00 15 .00 7 .00 7.00 7.00 14.00 10 .00 Y 50.00 15.00 Y 9.00 13.00 39.00 9.00 --------- 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 City of Carlsbad Inspection Request For: 3/1 /99 Permit# CB982774 Inspector Assignment: PY --- Title: 3356 SF+648 GAR+34 SF PORCH Description: PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD Type:SFD Sub Type: Job Address: 2158 VISTA LA NISA Suite: Lot 202 Location: l\PPLICANT: STANDARD PACIFIC Owner: STANDARD PACIFIC CORP Remarks: LATE AM REQUESTED Total Time: Phone: Inspector: ----- Requested By: JEFF Entered By: BARBARA CD Description Act Comments 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical --- tr--- Inspection History Date Description Act lnsp Comments 2/23/99 39 Final Electrical WC PY 2/22/99 39 Final Electrical PA PY EMR 2/19/99 89 Final Combo NS PY 12/28/98 18 Exterior Lath/Drywall AP PY 12/29/98 18 Exterior Lath/Drywall AP PY 12/23/98 17 Interior Lath/Drywall AP PY 12/23/98 18 Exterior Lath/Drywall co PY 12/23/98 23 GasfTesURepairs AP PY 12/22/98 82 Drywall/Ext Lath/Gas Test NS PY 12/15/98 84 Rough Combo AP PY 12/4/98 13 Shear Panels/HD's AP PY 11/13/98 15 Roof/Reroof AP PY ALREADY DONE 11/12/98 15 Roof/Reroof AP PY 11/10/98 15 Roof/Reroof NR PY NO SUPER PM 11/9/98 15 Roof/Reroof NR PY 11/6/98 15 Roof/Reroof NS PY 11/4/98 15 Roof/Reroof NS PY 9/17/98 11 Fig/Foundation/Piers AP PY City of Carlsbad Inspection Request Permit# CB982774 1.,-,ll./lnspector Assignment: Title: 3356 SF+648 GAR+34 SF PORCH Description: PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD Type:SFD Sub Type: Job Address: 2158 VISTA LA NISA Suite: Lot 202 Location: C\PPLICANT: STANDARD PACIFIC Owner: STANDARD PACIFIC CORP Remarks: FOR ROUTING PURPOSES ONLY Phone: Inspector: PY Total Time: Requested By: JEFF Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments ~--.-er--:-• fu-.~---,-------- Inspection History Date Description Act lnsp Comments 12/29/98 18 Exterior Lath/Drywall AP PY 12/28/98 18 Exterior Lath/Drywall AP PY 12/23/98 17 Interior Lath/Drywall AP PY 12/23/98 18 Exterior Lath/Drywall co PY 12/23/98 23 Gas/TesVRepairs AP PY 12/22/98 82 Drywall/Ext Lath/Gas Test NS PY 12/15/98 84 Rough Combo AP PY 12/4/98 13 Shear Panels/HD's AP PY 11/13/98 15 Roof/Reroof AP PY ALREADY DONE 11/12/98 15 Roof/Reroof AP PY 11/10/98 15 Roof/Reroof NR PY NO SUPER PM 11/9/98 15 Roof/Reroof NR PY 11/6/98 15 Roof/Reroof NS PY 11/4/98 15 Roof/Reroof NS PY 9/17/98 11 Fig/Foundation/Piers AP PY 9/9/98 21 Underground/Under Floor AP PY 9/9/98 21 Underground/Under Floor WC PY PREFERRED CONSTRUCTION INSPECTIONS, INC. 4888 Ronson Court "G" San Dieqo, Ca. 92111 (619) 576-9110 Fax (619) 576-7028 -------------------------------~---------------------------------------------- TEST REPORT JOB NO.: 2369 ----------------------------------------------------------------------------- JOB: ADDRESS: OWNER: CL IENT: SAN ALICIA 2158 VISTA LA MESA STANDARD PACIFIC HOMES STANDARD PACIFIC HOMES CONTRACTOR: MUELLER LEWI S CONCRETE ENGINEER: JEM III BLDG AUTH : CITY OF CARLSBAD ARCHITECT: BASSENIAN/LAGONI INSPECTOR: FERNANDO CARDENAS PERMIT NO: 982774 PLAN FILE: ----------------------------------------------------------------------------- FIELD LOCATION OF SPECIMEN SAMPLE OF: CONCRETE IN JOB OR STRUCTURE: LOT #202 WEST SIDE ----------------------------------------------------------------------------- MIX NO: 3475P MADE BY: FERNANDO CARDENAS PROPORTIONS: 4.75 SACK SLUMP: 4 3/4" ADMIXTURE: POZZ DATE MADE: 9/18/98 TYPE OF CEMENT: DATE RECEIVED: 9/21/98 CONCRETE SUPPLIER: ESCONDIDO READY MIX TICKET NO: 238157 ----------------------------------------------------------------------------- LABORATORY TEST DATA AGE TESTED 10 DAYS 28 DAYS 28 DAYS H DAYS SPECIMEN MARKING S: 31922 31923 31924 DATE TESTED: 9/28 10/16 10/16 AREA-SQ . IN.: 28.28 28 .28 28.28 ULTIMATE LOAD -LBS: 49000 UNIT STRESS -PSI: 1730 SPECIFIED STRENGTH 2500 AT 28 DAYS: ----------------------------------------------------------------------------- DISTRIBUTION: STANDARD PACIFIC HOMES MUELLER LEW I S CONCRETE JEM I II CITY OF CARLSBAD TEST METHODS -ASiM C39: C173: C172: C143: C231: C1231: C138: ____ c/dcL4l_-_ ENGINEER: City of Carlsbad 2075 Las Palmas Drive, Carlsbad Callforn~ 92009 INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CALL PRIOR TO 2:00 P.M. FOR NEXT WORKDAY INSPECTION • BUILDING INSPE~TION: (760) 438•3101 ~~~'..e.,,~~~~~~'-J:'.'..~w.!~>:;--------LOT NO./SUITE: t2,tt):L, DATE BUILDING OTHER APPROVED TO COVER Type of lnapectlon Date Inspector Notes BlJILDINC I I ,I FOUNDATION l~l/1/q_.r #'Y REINFORCED STEEL I , / MASONRY . □ GROUT □ WALL DRAINS TILT PANELS POUR STRIPS COLUMN FOOTINGS SUBFRAME □ FLOOR □ CEILING ROOF SHEATHING II J-z./tt'( h i EXT. SHEAR PANELS ;;;../ './ /qy _M.Y FRAME 1'1.I 1 ,i( /~I ,:, INSULATION l . EXTERIOR LA TH l'J/~x-/9'1 A, INTERIOR LATH & DRYWALL J.2/1..i,,/qf k_ -FINAL PLUMBING 0 SEWER AND BUCO □ PL/CO I J UNDERGROUND □ WASTE □ WATER ~'/"'1//y( 1-"V' TOP OUT □WASTE □ WATER ,.,, 1/ ~, I/ .-.JI TUB~ SHOWER PAN \ ·-' ' GAS TEST □ GAS PIPING h.J ,_ \ Jo. y ~'1,./' □ WATER HEATER □ SOLARWATER I ' -- FINAL ELECTIUC._L □ ELECTRIC UNDERGROUND □ UFER \ ROUGH ELECTRIC WALLS ,_ .) ,.J ROUCH ELECTRIC CEILING I ..,. t--' WV (\N" □ ELECTRIC SERVICE □ TEMPORARY □ BONDING □POOL FINAL MECHIIN/0.L UNDERGROUND DUCTS & PIPING ' □ DUCT & PLEM.O REF. PIPING )~ ~/ ,.~ ""' HEAT -AIR CONO. SYSTEMS I \l"' ' "' N\ VENTILATING SYSTEMS ' ' FINAL I CALL FOR FINAL INSPECTION WHEN ,ULAPPP.OPRIA TE ITEMS ABOVE HA \JF BEEN AP' OVED l , FINAL Sign When Appropriate . // I I _,_ I / ' _,.. Buildins Dept. (Inspections) 438-3101 I~ i'>"' ,., ,. . -. ,, 't::J4 ,r , .. Fire Department _ill ""A • 6---. I•• ~{QC.,J ~ ~) Ii'~ I l . / Planning Department 436-1161 i w:J 1 tJ:1,£'1!1 ~ v.~ ~,.M.JI i--/ Ensineering Dept. (Inspections) 438-3891 "Z·Z,,."/1 :~·~ ~ Building lnspectON (7am-4pm) 43&-3550 CMWD 438-2 722 Ext 15 Water Inspections 438-3891 REV 6/96 SEE BACK FOR SPECIAL NOTES . / ,. .,/ 1--· 50 391;td LPi1EP509l 50:91 5551/10/E0