HomeMy WebLinkAbout2158 VISTA LA NISA; ; CB982774; Permitv5o3 5 olf{p
09/04/98 09:04
Page 1 of 1
B U I L D I N G P E R M I T Permit No: CB982774
Project No: A9803628
Development No: DEV89110
Job Address : 2158 VISTA LA NISA Suite:
Permit Type: SINGLE FAMILY DWLNG -DETACHED
Parcel No: 255-262-15-00 Lot#: 202
Valuation: 290,343 Construction Type: VN
Occupancy Group: Reference#: CT 88-03 Status:
Description: 3356 SF+648 GAR+34 SF PORCH Applied :
: PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD Apr/Issue:
Entered By:
619 292-2200
ISSUED
04/17/98
09/04/98
RMA
Appl/Ownr : STANDARD PACIFIC
9 3 3 5 CHESAPEA.KE DR
SAN DIEGO CA 92123
Plan Check Numbers > ORIG
0809 09/04/98 0001 01
97 3162 PCK 982518 C-PRHT
02
12844-32
*** Fees Required *** ***
Fees: 12,844.32
Adjustments: . 00
Total Fees:
Fees Collected & Credits
Tot a l Credits:
Total Pa yments :
Ba l ance Due:
.00
.00
12,844.32
***
Fee description Units Fee/Unit Ext fee Data
Number of Bedrooms ) 5
Number of Bathrooms . > 4.50
Building Permit
Plan Check ~ /
Strong Motion Fee
Enter Plan Check @is (Un~ Amt v 67 .00
Enter "Y" to Au to ale P. F . I\ >
Enter "Y" to Autoc le T.I ,P. >
Payoff Fee for CFD > 4254 .32
Enter LFM Fee (Zones=6,11,1 2) > 310.00
Enter "Y" for Plumbing I ssu.e Fee >
Each Plumbing Fixture or Trap > 20
Each Building Sewer > 1
Each Install/Repair Water Li n e ~ 1
Each Water Heater and/or V~nt > 1
Gas Piping System > 1
Each Vacuum Breaker > 2
Enter "Y" for Electric Issue Fee >
Single Phase Per AMP > 200
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts/Heat Pumps > 1
Each Install Fireplace > 2
Each Exhaust Fan > 6
Each Install/Reloc Vent > 2
CITY OF CARLSBAD
7 I
J
-1.00
7 .00
15 .00
7.00
7.00
7.00
7.00
.25
9.00
6 .50
6.50
4.50
5 .00
4.50
1290.00
839.00
29.00
-67 .00
5284 .00 Y
550 .00 Y
4254.32
310.00
20.00 Y
140.00
15 .00
7 .00
7.00
7.00
14.00
10 .00 Y
50.00
15.00 Y
9.00
13.00
39.00
9.00
---------
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
City of Carlsbad Inspection Request
For: 3/1 /99
Permit# CB982774 Inspector Assignment: PY ---
Title: 3356 SF+648 GAR+34 SF PORCH
Description: PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD
Type:SFD Sub Type:
Job Address: 2158 VISTA LA NISA
Suite: Lot 202
Location:
l\PPLICANT: STANDARD PACIFIC
Owner: STANDARD PACIFIC CORP
Remarks: LATE AM REQUESTED
Total Time:
Phone:
Inspector: -----
Requested By: JEFF
Entered By: BARBARA
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
---
tr---
Inspection History
Date Description Act lnsp Comments
2/23/99 39 Final Electrical WC PY
2/22/99 39 Final Electrical PA PY EMR
2/19/99 89 Final Combo NS PY
12/28/98 18 Exterior Lath/Drywall AP PY
12/29/98 18 Exterior Lath/Drywall AP PY
12/23/98 17 Interior Lath/Drywall AP PY
12/23/98 18 Exterior Lath/Drywall co PY
12/23/98 23 GasfTesURepairs AP PY
12/22/98 82 Drywall/Ext Lath/Gas Test NS PY
12/15/98 84 Rough Combo AP PY
12/4/98 13 Shear Panels/HD's AP PY
11/13/98 15 Roof/Reroof AP PY ALREADY DONE
11/12/98 15 Roof/Reroof AP PY
11/10/98 15 Roof/Reroof NR PY NO SUPER PM
11/9/98 15 Roof/Reroof NR PY
11/6/98 15 Roof/Reroof NS PY
11/4/98 15 Roof/Reroof NS PY
9/17/98 11 Fig/Foundation/Piers AP PY
City of Carlsbad Inspection Request
Permit# CB982774 1.,-,ll./lnspector Assignment:
Title: 3356 SF+648 GAR+34 SF PORCH
Description: PLN 4,PHS 4,VILLAGE H,LA COSTA,STANDARD
Type:SFD Sub Type:
Job Address: 2158 VISTA LA NISA
Suite: Lot 202
Location:
C\PPLICANT: STANDARD PACIFIC
Owner: STANDARD PACIFIC CORP
Remarks: FOR ROUTING PURPOSES ONLY
Phone:
Inspector:
PY
Total Time: Requested By: JEFF
Entered By: CHRISTINE
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comments
~--.-er--:-• fu-.~---,--------
Inspection History
Date Description Act lnsp Comments
12/29/98 18 Exterior Lath/Drywall AP PY
12/28/98 18 Exterior Lath/Drywall AP PY
12/23/98 17 Interior Lath/Drywall AP PY
12/23/98 18 Exterior Lath/Drywall co PY
12/23/98 23 Gas/TesVRepairs AP PY
12/22/98 82 Drywall/Ext Lath/Gas Test NS PY
12/15/98 84 Rough Combo AP PY
12/4/98 13 Shear Panels/HD's AP PY
11/13/98 15 Roof/Reroof AP PY ALREADY DONE
11/12/98 15 Roof/Reroof AP PY
11/10/98 15 Roof/Reroof NR PY NO SUPER PM
11/9/98 15 Roof/Reroof NR PY
11/6/98 15 Roof/Reroof NS PY
11/4/98 15 Roof/Reroof NS PY
9/17/98 11 Fig/Foundation/Piers AP PY
9/9/98 21 Underground/Under Floor AP PY
9/9/98 21 Underground/Under Floor WC PY
PREFERRED CONSTRUCTION INSPECTIONS, INC.
4888 Ronson Court "G"
San Dieqo, Ca. 92111
(619) 576-9110
Fax (619) 576-7028
-------------------------------~----------------------------------------------
TEST REPORT JOB NO.: 2369 -----------------------------------------------------------------------------
JOB:
ADDRESS:
OWNER:
CL IENT:
SAN ALICIA
2158 VISTA LA MESA
STANDARD PACIFIC HOMES
STANDARD PACIFIC HOMES
CONTRACTOR: MUELLER LEWI S CONCRETE
ENGINEER: JEM III
BLDG AUTH : CITY OF CARLSBAD ARCHITECT: BASSENIAN/LAGONI
INSPECTOR: FERNANDO CARDENAS PERMIT NO: 982774 PLAN FILE: -----------------------------------------------------------------------------
FIELD LOCATION OF SPECIMEN
SAMPLE OF: CONCRETE IN JOB OR STRUCTURE: LOT #202 WEST SIDE -----------------------------------------------------------------------------
MIX NO: 3475P MADE BY: FERNANDO CARDENAS
PROPORTIONS: 4.75 SACK SLUMP: 4 3/4"
ADMIXTURE: POZZ DATE MADE: 9/18/98
TYPE OF CEMENT: DATE RECEIVED: 9/21/98
CONCRETE SUPPLIER: ESCONDIDO READY MIX
TICKET NO: 238157 -----------------------------------------------------------------------------
LABORATORY TEST DATA
AGE TESTED 10 DAYS 28 DAYS 28 DAYS H DAYS
SPECIMEN MARKING S: 31922 31923 31924
DATE TESTED: 9/28 10/16 10/16
AREA-SQ . IN.: 28.28 28 .28 28.28
ULTIMATE LOAD -LBS: 49000
UNIT STRESS -PSI: 1730
SPECIFIED STRENGTH 2500 AT 28 DAYS: -----------------------------------------------------------------------------
DISTRIBUTION: STANDARD PACIFIC HOMES
MUELLER LEW I S CONCRETE
JEM I II
CITY OF CARLSBAD
TEST METHODS -ASiM C39: C173:
C172: C143:
C231: C1231:
C138:
____ c/dcL4l_-_
ENGINEER:
City of Carlsbad
2075 Las Palmas Drive, Carlsbad Callforn~ 92009
INSPECTION RECORD
INSPECTION RECORD CARD WITH APPROVED PLANS
MUST BE KEPT ON THE JOB
CALL PRIOR TO 2:00 P.M. FOR NEXT WORKDAY INSPECTION
• BUILDING INSPE~TION: (760) 438•3101
~~~'..e.,,~~~~~~'-J:'.'..~w.!~>:;--------LOT NO./SUITE: t2,tt):L,
DATE
BUILDING
OTHER
APPROVED TO COVER
Type of lnapectlon Date Inspector Notes
BlJILDINC I I ,I
FOUNDATION l~l/1/q_.r #'Y
REINFORCED STEEL I , /
MASONRY .
□ GROUT □ WALL DRAINS
TILT PANELS
POUR STRIPS
COLUMN FOOTINGS
SUBFRAME □ FLOOR □ CEILING
ROOF SHEATHING II J-z./tt'( h i
EXT. SHEAR PANELS ;;;../ './ /qy _M.Y
FRAME 1'1.I 1 ,i( /~I ,:,
INSULATION l .
EXTERIOR LA TH l'J/~x-/9'1 A,
INTERIOR LATH & DRYWALL J.2/1..i,,/qf k_ -FINAL
PLUMBING
0 SEWER AND BUCO □ PL/CO I J
UNDERGROUND □ WASTE □ WATER ~'/"'1//y( 1-"V'
TOP OUT □WASTE □ WATER ,.,, 1/ ~, I/ .-.JI
TUB~ SHOWER PAN \ ·-' '
GAS TEST □ GAS PIPING h.J ,_ \ Jo. y ~'1,./'
□ WATER HEATER □ SOLARWATER I ' --
FINAL
ELECTIUC._L
□ ELECTRIC UNDERGROUND □ UFER \
ROUGH ELECTRIC WALLS ,_ .) ,.J
ROUCH ELECTRIC CEILING I ..,. t--' WV (\N"
□ ELECTRIC SERVICE □ TEMPORARY
□ BONDING □POOL
FINAL
MECHIIN/0.L
UNDERGROUND DUCTS & PIPING ' □ DUCT & PLEM.O REF. PIPING )~ ~/ ,.~ ""'
HEAT -AIR CONO. SYSTEMS I \l"' ' "' N\
VENTILATING SYSTEMS ' '
FINAL I
CALL FOR FINAL INSPECTION WHEN ,ULAPPP.OPRIA TE ITEMS ABOVE HA \JF BEEN AP' OVED l ,
FINAL Sign When Appropriate .
// I I _,_ I / ' _,..
Buildins Dept. (Inspections) 438-3101 I~ i'>"' ,., ,. . -. ,, 't::J4 ,r , ..
Fire Department _ill ""A • 6---. I•• ~{QC.,J ~ ~) Ii'~ I l . /
Planning Department 436-1161 i w:J 1 tJ:1,£'1!1 ~ v.~ ~,.M.JI i--/
Ensineering Dept. (Inspections) 438-3891 "Z·Z,,."/1 :~·~ ~
Building lnspectON (7am-4pm) 43&-3550
CMWD 438-2 722 Ext 15
Water Inspections 438-3891
REV 6/96 SEE BACK FOR SPECIAL NOTES
.
/
,. .,/
1--·
50 391;td LPi1EP509l 50:91 5551/10/E0