HomeMy WebLinkAbout2149 VISTA LA NISA; ; CB982766; Permitv5o55J0&
09/04/98 09 :04
Page 1 of 1
B U I L D I N G
Job Address: 2149 VISTA LA NISA
P E R M I T
Suite:
Permit No: CB982766
Projec t No: A9803620
Development No: DEV89110
Permit Type: SINGLE FAMILY DWLNG -DETACHED
Parcel No: 255-262-12-00 Lot#: 199
Valuatiop: 274,213 Construction Type: VN
Occupancy Group: Reference#: CT88-03 Status:
Description: 3166 SF+614 GAR+66 SF PORCH, Applied:
ISSUED
04/17/98
09/04/98
RMA
: PLN 3,PHS 4,VILLAGE H,LA COSTA,STANDARD Apr/Issue:
Appl/Ownr : STANDARD PACIFIC
9335 CHESAPEAKE DR
SAN DIEGO CA 92123
Plan Check Numbers > ORIG
*** Fees Required *** ***
Entered By:
619 292-2260
0809 09/04/98 0001 01
C-PRMT
973162 PCK 982518
Fees Collected & Credits
02
12466-32
*** --------------------------------------------
Fees: 12,466.32
Adjustments: .00
Total Fees: 12,466.3
Fee description
Number o f Bedrooms
Number of Bathroom~
Building Permit
Plan Check
Strong Motion Fee
Enter Plan Check ~is o nt Amt
Enter "Y" to Autoc;alc P.F .F.
Enter "Y" to Autoc~lc T.I.F.
Payoff Fee for CFD
Enter LFM Fee (Zones•6,11,1~)
Enter "Y" for Plumbing Issue Pee
Each Plumbing Fixture or Trap
Each Building Sewer
Each Install/Repair Wate Line
Each Water Heater and/or V~nt
Gas Piping System
Each Vacuum Breaker
Enter "Y" for Electric Issue Fee
Single Phase Per AMP
>
. >
> > > >
> > >
)
> > >
>
> >
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts/Heat Pumps >
Each Install Fireplace >
> > Each Exhaust Fan
Each Install/Reloc Vent
Total Credits:
Total Payme ts:
Balance Due:
.00
.00
12,466.32
Units Fee/Unit Ext fee Data
5
4.50
64.00
4254~32
310.00
21
1
1
1
2
200
1
2
6
2
7
t I
-1 .00
7.00
5.00
7.00
7.00
7.00
7.00
.25
9.00
6.50
6.50
4.50
5.00
4.50
1234.00
802.00
27.00
-64.00
4991.00 Y
550.00 Y
4254.32
310.00
20.00 Y
147.00
15.00
7.00
7.00
7.00
14.00
10.00 Y
50.00
15.00 Y
9.00
13.00
39.00
9.00
\)VAL
c.J~
I ':;LEARA CE ~:,,\!¼A. 41 > I , ___ .,
-•..-----· --
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
City of Carlsbad Inspection Request
For: 2/24/99
Permit# CB982766 Inspector Assignment: PY ---
Title: 3166 SF+614 GAR+66 SF PORCH,
Description: PLN 3,PHS 4,VILLAGE H,LA COSTA,STANDARD
Type:SFD Sub Type:
Job Address: 2149 VISTA LA NISA
Suite: Lot 199
Location:
4-PPLICANT : STANDARD PACIFIC
Owner: STANDARD PACIFIC CORP
Remarks: AM PLEASE
Total Time:
Phone: 7609431052
Inspector: -----
Requested By: JEFF
Entered By: CHRISTINE
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
W-----
Inspection History
Date Description Act lnsp Comments
2/19/99 89 Final Combo NS PY
2/9/99 39 Final Electrical PA PY EMR
12/16/98 82 Drywall/Ext Lath/Gas Test AP PY
12/8/98 84 Rough Combo AP PY EXTEND C/0
11/19/98 13 Shear Panels/HD's AP PY
11/18/98 13 Shear Panels/HD's co PY NEED WINDOW
11/16/98 13 Shear Panels/HD's NR PY
11/4/98 15 Roof/Reroof AP PY
11/3/98 15 Roof/Reroof NS PY
9/16/98 11 Fig/Foundation/Piers AP PY
9/9/98 21 Underground/Under Floor AP PY
PREFERRED CONSTRUCTION INSPECTIONS, INC.
4888 Ronson Court "G"
San Diego, Ca . 92111
(619) 576-9110
Fax (619) 576-7028
------------------------------------------------------------------------------
TEST REPORT JOB NO. : 2369 ------------.--------------------------------------------------------------
JOB: .SAN AL I CIA
ADDRESS: 2149 VISTA LA MESA
OWNER:
CLIENT:
STANDARD PACIFIC HOMES
STANDARD PACIFIC HOMES
CONTRACTOR: MUELLER LEWIS CONCRETE
ENGINEER: JEM III
BLDG AUTH: CITY OF CARLSBAD ARCHITECT: BASSENIAN/LAGONI
INSPECTOR: FERNANDO CARDENAS PERMIT NO: 982766 PLAN FILE: -----------------------------------------------------------------------------
FIELD LOCATION OF SPECIMEN
SAMPLE OF: CONCRETE IN JOB OR STRUCTURE: LOT #199 SOUTHEAST CORNER -----------------------------------------------------------------------------
MIX NO:
PROPORTION S:
ADMIXTURE:
TYPE OF CEMENT:
3475P
4 .75 SACK
POZZ
MADE BY:
SLUMP:
DATE MADE:
FERNANDO CARDENAS
4 3/4"
9/17/98
DATE RECEIVED: 9/18/98
CONCRETE SUPPLIER: ESCONDIDO READY MI X
TICKET NO: 230093 -----------------------------------------------------------------------------
LABORATORY TEST DATA
AGE TESTED 10 DAYS 28 DAYS 28 DAYS H DAYS
SPECIMEN MARKINGS: 31883 31884 3 1885
DATE TESTED: 9/28 10/15 10/15
AREA-SQ. IN.: 28 .28 28.28 28.28
ULTIMATE LOAD -LB S : 51000
UNIT STRESS -PSI: 1 800
SPECIFIED STRENGTH
AT 28 DAYS: 2500
-----------------------------------------------------------------------' DISTRIBUTION : STANDARD PACIFIC HOMES
MUELLER LEWIS CONCRETE
JEM III
CITY OF CARLSBAD
TEST METHODS -ASTM C39: C173:
C172: C143:
C231: C1231:
C138:
City of Carlsbad
2075 Lu Pal~, Drive, Carl,~d Callfornl~ 92009
INSPECTION RECORD
INSPECTION RECORD CARD WITH APPROVED PLANS
MUST BE KEPT ON THE JOB
) ,i.
CALL PRIOR TO 2:00 P.M. FOR NEXT WORKDAY INSPECTION
"j.1-f _., 1··
·'' t. ~J
~UILDING l~ECT!ON: (760) 438-3101
)08 ADDRESS: ...-,::z:::,t,....;.z..,~..s:::...,..,..,~-4.,.14~:........:..:: ~=~::..--------LOT NO./SUITE: ... ) .... ~,_~9.__ ___ _
OWNERS NAME: -~--=J:~::;r,e,;Lf+.~~~~9'=-::::::..Q.:.._ ___ --;~~9"-7"'1:r-_:::---,r,n~-;---------
uPANCY DATE
PERMIT NO.
BUILDING
OTHER
APPROVED TO COVER
Type of Inspection Date Inspector Notes
BUILDING j l l (\ I\/ V
FOUNDATION q/}IJ 41. J.~ \.\[)lll ,. .V \ -· "J\ \,·
REINFORCED STEEL ' I -I/ I ~
MASONRY I
□GROUT □ WAI.L DRAINS
TILT P,4.NELS
POUR STRIPS
COLUMN FOOTINGS
SUBFRAME 0 FLOOR □ CEILING ' . -
ROOF SHEATHING I 11" / 'i'YJ r.'V
EXT. SHEAR PANELS I I /'1~/4i't Ml
FRAME J i_f 'ii 'i J rr JL..
JNSULATION I
EXTERIOR LA TH I. I, I~,/ I
INTERIOR LATH & DRYWALL ,,,,,, ., r7
FINAL I
PLUMB/NC
□ SEWER AND BUCO □PUCO J •
UNDERCROUND □WASTE □ WATER "I /Cji/ 11,: ~ J / A /J
TOP OUT D WASTE □ WATER I.JI P'I" r ~ IL/% ~:£1 ,,.~'71 ~
TUB _.t,ND SHOWER PAN I I ( ,.,/' ., r
l.Jji!""GAS TEST 0 GAS PIPING 11J11Jaff ~
0 WATER HEATER □ SOLAR WATER • l /
FINAL
ELECTR/0.L
0 ELECTRIC UNDERGROUND 0 UFER
ROUGH ELECTRIC WALLS I .J rJ!-.v ~
ROUGH ELECTRIC CEILING I ,,,, • I • 7 ·
□ ELECTRIC SERVICE □TEMPORARY
□BONOINC □ POOL
FINAL
MECHANICAL
UNDERGROUND DUCTS & PIPING I I ,
0 DUCT & PLEM.□ REF. PIPING IJ 2,/ ')' /~ y ~/
HEAT · AIR COND. SYSTEMS . r
VENTILATING SYSTEMS
FINAL
CALL FOR FINAL INSPECTION WHEN ALLAPPROPRU TE ITEMS ABOVE HAVE BEEN A PPROVED
FINAL Sign When Appropr~te
Building Dept. (Inspections) 438-3101
Fire Department 931-lill
Planning Department 438·1161
Engineering Dept. (Inspections) 438-3891
Building Inspectors (7am--4pml 43&-3550
CMWO 438-2722 Ext 15
Wat.er Inspections 43B-3891
REV 6/96 SEE BACK FOR SPECIAL NOTES
L0 39'vd OI~IO'vd Go'vGN'v~S LP0!EP609L 50:91 666!/!0/E0