Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Saturn Electric Inc; 2025-07-29; PWM26-3895FAC
CARLSBAD MUNICIPAL WATER DISTRICT MINOR PUBLIC WORKS CONTRACT PWM26-3895FAC CARLSBAD MUNICIPAL WATER DISTRICT EV CHARGING STATIONS; CONT. NO. 5063 This contract is made on the ______ day of __________ � 2025 ("Contract"), by the Carlsbad Municipal Water District, a Public Agency organized under the Municipal Water Act of 1911, and a Subsidiary District of the City of Carlsbad, California, hereinafter referred to as "CMWD" and Saturn Electric, Inc., a California corporation whose principal place of business is 7552 Trade Street, San Diego, California, 92121 ("Contractor"). CMWD and Contractor agree as follows: DESCRIPTION OF WORK. Contractor shall perform all work specified in the Contract documents for the project described by these Contract Documents (hereinafter called "Project"). PROVISIONS OF LABOR AND MATERIALS. Contractor shall provide all labor, materials, tools, equipment, and personnel to perform the work specified by the Contract Documents unless excepted elsewhere in this Contract. CONTRACT DOCUMENTS. The Contract Documents consist of this Contract, exhibits to this Contract, Contractor's Proposal, the Plans and Specifications, the General Provisions, as contained in the Standard Specifications for Public Works Construction "Greenbook," latest edition and including all errata; Part 1 General Provisions, addendum(s) to said Plans and Specifications, and all proper amendments and changes made thereto in accordance with this Contract or the Plans and Specifications, all of which are incorporated herein by this reference. When in conflict, this Contract will supersede terms and conditions in the Contractor's proposal. LABOR. Contractor will employ only skilled workers and abide by all State laws and City of Carlsbad Ordinances governing labor. GUARANTEE. Contractor guarantees all labor and materials furnished and agrees to complete the Project in accordance with directions and subject to inspection approval and acceptance by: Si Phan (CMWD Project Manager). PAYMENT. CMWD shall withhold retention as required by Public Contract Code Section 9203. PREVAILING WAGE RATES. Any construction, alteration, demolition, repair, installation, and maintenance work, including work performed during design and preconstruction such as inspection and land surveying work, cumulatively exceeding $1,000 and performed under this Contract constitute "public works" under California Labor Code Section 1720 et seq., and are subject to state prevailing wage laws. The general prevailing rate of wages, for each craft or type of worker needed to execute the contract, shall be those as determined by the Director of Industrial Relations pursuant to the Sections 1770, 1773 and 1773.1 of the California Labor Code. Consistent with the requirement of Section 1773.2 of the California Labor code, a current copy of applicable wage rates may be obtained via the internet at: www.dir.ca.gov/dlsr/. Contractor shall not pay less than the said specified prevailing rates of wages to all such workers employed by him or her in the execution of the Contract. Contractor and any subcontractors shall comply with Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 1 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B July29th PWM26-3895FAC Section 1776 of the California Labor Code, which requires keeping accurate payroll records, verifying and certifying payroll records, and making them available for inspection. Contractor shall require any subcontractors to comply with Labor Code Section 1776. DIR REGISTRATION. California Labor Code Section 1725.5 requires the Contractor and any subcontractor or subconsultant performing any public work under this Contract to be currently registered with the California Department of Industrial Relations ('DIR'), as specified in Labor Code Section 1725.5. Labor Code Section 1771.1 provides that a contractor or subcontractor/subconsultant shall not be qualified to engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Labor Code section 1725.5. Prior to the performance of public work by any subcontractor or subconsultant under this Contract, Contractor must furnish CMWD with the subcontractor or subconsultant's current DIR registration number. CALIFORNIA AIR RESOURCE BOARD (CARB) ADVANCED CLEAN FLEETS REGULATION. Contractor's vehicles with a gross vehicle weight rating greater than 8,500 lbs. and light-duty package delivery vehicles operated in California may be subject to the California Air Resources Board (CARB) Advanced Clean Fleets regulations. Such vehicles may therefore be subject to requirements to reduce emissions of air pollutants. For more information, please visit the CARB Advanced Clean Fleets webpage at https ://ww2. a rb.ca .gov/ our-work/programs/ advanced-clean-fleets. CALIFORNIA AIR RESOURCES BOARD (CARB) IN-USE OFF-ROAD DIESEL FUELED FLEETS REGULATION. Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title 13 of the California Code of Regulations section 2449 et seq. throughout the term of the Project. More information about the requirements and Contractor's required certification is provided in Exhibit D. CONSTRUCTION MANAGEMENT SOFTWARE. Procore Project Management and Collaboration System. This project may utilize the Owner's Procore (www.procore.com) online project management and document control platform. The intent of utilizing Procore is to reduce cost and schedule risk, improve quality and safety, and maintain a healthy team dynamic by improving information flow, reducing non productive activities, reducing rework and decreasing turnaround times. The Contractor is required to create a free web-based Procore user account(s) and utilize web-based training / tutorials (as needed) to become familiar with the system. Unless the Engineer approves otherwise, the Contractor shall process all project documents through Procore because this platform will be used to submit, track, distribute and collaborate on project. If unfamiliar or not otherwise trained with Procore, Contractor and applicable team members shall complete a free training certification course located at http://learn.procore.com/procore-certification-subcontractor. The Contractor is responsible for attaining their own Proco re support, as needed, either through the on line training or reaching out to the Procore support team. It will be the responsibility of the Contractor to regularly check Procore and review updated documents as they are added. There will be no cost to the Contractor for use of Proco re. It is recommended that the Contractor provide mobile access for Windows, iOS located at https://apps.apple.com/us/app/procore-construction-management/id374930542 or Android devices located at https://play.google.com/store/apps/details?id=com.procore.activities with the Procore App installed to at least one on-site individual to provide real-time access to current posted drawings, specifications, RFls, submittals, schedules, change orders, project documents, as well as any deficient observations or punch list items. Providing mobile access will improve communication, efficiency, and Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 2 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-3895FAC productivity for all parties. The use of Proco re for project management does not relieve the contractor of any other requirements as may be specified in the contract documents. Contractor hereby agrees that any contract claim submitted to CMWD must be asserted FALSE CLAIMS. as part of the contract process as set forth in this Contract and not in anticipation of litigation or in conjunction with litigation. Contractor acknowledges that California Government Code sections 12650 et seq., the False Claims Act, provides for civil penalties where a person knowingly submits a false claim to a public entity. These provisions include false claims made with deliberate ignorance of the false information or in reckless disregard of the truth or falsity of the information. The provisions of Carlsbad Municipal Code sections 3.32.025, 3.32.026, 3.32.027 and 3.32.028 pertaining to false claims are incorporated herein by reference. Contractor hereby acknowledges that the filing of a false claim may subject the Contractor to an administrative debarment proceeding wherein the contractor may be prevented from further bidding on public contracts for a period of up to five years and that debarment by another jurisdiction is grounds for CMWD to disqualify the Contractor or subcontractor from participating in contract bidding. Signature: Print Name: �>::-: Timothy Allen Dudek REQUIRED INSURANCE.The successful contractor shall provide to CMWD, a Certification of Commercial General Liability and Property Damage Insurance and a Certificate of Workers' Compensation Insurance indicating coverage in a form approved by the California Insurance Commission. The certificates shall indicate coverage during the period of the contract and must be furnished to CMWD prior to the start of work. The minimum limits of liability insurance are to be placed with California admitted insurers that have a current Best's Key Rating of not less than "A-:VII"; OR with a surplus line insurer on the State of California's List of Approved Surplus Line Insurers (LASLI) with a rating in the latest Best's Key Rating Guide of at least "A:X"; OR an alien non-admitted insurer listed by the National Association of Insurance Commissioners (NAIC) latest quarterly listings report. Commercial General Liability Insurance written on an "occurrence" basis, including personal & advertising injury, with limits no less than $2,000,000 per occurrence. If a general aggregate limit applies, either the general aggregate limit shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit. Property damage insurance in an amount of not less than ........ $2,000,000 Automobile Liability Insurance in the amount of $2,000,000 combined single limit per accident for bodily injury and property damage. In addition, the auto policy must cover any vehicle used in the performance of the contract, used onsite or offsite, whether owned, non-owned or hired, and whether scheduled or non-scheduled. The automobile insurance certificate must state the coverage is for "any auto" and cannot be limited in any manner. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 3 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-3895FAC The above policies shall have non-cancellation clauses providing that 30 days written notice shall be given to CMWD prior to such cancellation. The policies shall name CMWD as an additional insured. The full limits available to the named insured shall also be available and applicable to CMWD as an additional insured. WORKERS COMPENSATION AND EMPLOYER'S LIABILITY. Worker's Compensation limits as required by the California Labor Code. Workers' Compensation will not be required if Contractor has no employees and provides, to City's satisfaction, a declaration stating this. BUSINESS LICENSE. The Contractor and all subcontractors are required to have and maintain a valid City of Carlsbad Business License for the duration of the contract. INDEMNITY. Contractor agrees to defend (with counsel approved by CMWD), indemnify, and hold harmless CMWD, the City of Carlsbad, and its officers, elected and appointed officials, employees and volunteers from and against all claims, loss, damage, injury and liability of every kind, nature and description, directly or indirectly arising from or in connection with the performance of the Contract or work; or from any failure or alleged failure of Contractor to comply with any applicable law, rules or regulations including those related to safety and health; and from any and all claims, loss, damages, injury and liability, howsoever the same may be caused, resulting directly or indirectly from the nature of the work covered by the Contract, except for loss or damage caused by the sole or active negligence or willful misconduct of CMWD. The expenses of defense include all costs and expenses including attorneys' fees for litigation, arbitration, or other dispute resolution method. THIRD PARTY RIGHTS. Nothing in this Agreement should be construed to give any rights or benefits to any party other than the City and Contractor. JURISDICTION AND VENUE. This Agreement shall be interpreted in accordance with the laws of the State of California. The Contractor agrees and hereby stipulates that the proper venue and jurisdiction for resolution of any disputes between the parties arising out of this Contract is San Diego County, California. Start Work: Contractor agrees to start within five (S) working days after receipt of Notice to Proceed. Completion: Contractor agrees to complete work within twenty (20) working days after receipt of Notice to Proceed. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 4 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B CONTRACTOR'S INFORMATION. Saturn Electric, Inc. (name of Contractor) 219097 (Contractor's license number) Cl0,A, B 6/30/2026 (license class. and exp. date) 1000007128 6/30/2026 (DIR registration number/exp. date) PWM26-3895FAC 7552 Trade St. (street address) San Diego, CA, 92121 (city/state/zip) 858-271-4100 (telephone no.) tim@saturnelectric.com (e-mail address) AUTHORITY. The individuals executing this Contract and the instruments referenced in it on behalf of Contractor each represent and warrant that they have the legal power, right and actual authority to bind Contractor to the terms and conditions of this Contract. [signatures on following page] Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 5 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B CONTRACTOR SATURN ELECTRIC, INC., a California corporation By: By: ...., __ _ (sign here) Timothy Allen Dudek, President and Chief Financial Officer (print name, title) (sign here) print name, title) PWM26-3895FAC CARLSBAD MUNICIPAL WATER DISTRICT, a Public Agency organized under the Municipal Water Act of 1911, and a Subsidiary District of the City of Carlsbad By: Paz Gomez, Deputy City Manager, Public Works, as authorized by the City Manager ATTEST: SHERRY FREISINGER, Secretary By: Assistant Secretary If required by CMWD, proper notarial acknowledgment of execution by Contractor must be attached.� corporation, Contract must be signed by one corporate officer from each of the following two groups: Group A Chairman, President, orVice-President Group B Secretary, Assistant Secretary, CFO or Assistant Treasurer Otherwise, the corporation must attach a resolution certified by the secretary or assistant secretary under corporate seal empowering the officer(s) signing to bind the corporation. APPROVED AS TO FORM: CINDIE K. McMAHON, General Counsel BY: -------------Assistant General Counsel Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 6 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-389SFAC EXHIBIT A LISTING OF SUBCONTRACTORS BY GENERAL CONTRACTOR Set forth below is the full name and location of the place of business of each sub-contractor whom the Contractor proposes to subcontract portions of the Project in excess of one-half of one percent of the total bid, and the portion of the Project which will be done by each sub-contractor for each subcontract. NOTE: The Contractor understands that if it fails to specify a subcontractor for any portion of the Project to be performed under the contract in excess of one-half of one percent of the bid, the contractor shall be deemed to have agreed to perform such portion, and that the Contractor shall not be permitted to sublet or subcontract that portion of the work, except in cases of public emergency or necessity, and then only after a finding, reduced in writing as a public record of the Awarding Authority, setting forth the facts constituting the emergency or necessity in accordance with the provisions of the Subletting and Subcontracting Fair Practices Act (Section 4100 et seq. of the California Public Contract Code). If no subcontractors are to be employed on the project, enter the word "NONE." SUBCONTRACTORS Type of Work to Business Name and Address DIR Registration License No., %of be No. & Exp. Date Classification Total Subcontracted & Expiration Contract Date nCJY"A.- Total% Subcontracted: _ _;0�--�f-'o.._ __ _ The Contractor must perform no less than 50% of the work with its own forces. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 7 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-3895FAC EXHIBIT B CARLSBAD MUNICIPAL WATER DISTRICT EV CHARGING STATIONS Contractor to prepare, install and commission for active charging service, two (2) Level 2 Powercharge/ AssetWorks E35DWP-CR charging stations, conduits, conductors, circuit breakers/subpanel, and concrete pads/footings at the Carlsbad Municipal Water District building located at 5950 El Camino Real, Carlsbad, California 92008. Work shall be completed as per Plans, the descriptions below, and in alignment with the attached proposal #13825800 which is prepared by Saturn Electric. ITEM NO. UNIT QTY DESCRIPTION PRICE 1 LUMP 1 Install EV chargers and related works per plans $35,500 SUM which includes but not limited to the following: . Obtain building permit at the City Building department (city to pay the permit fee), . Furnish wall coring (if needed), trenching, backfill, pavement restoration, building wall waterproofing in accordance with city standards, . Install electrical work (subpanel/circuit breakers, conduits, conductors, 2x Level 2 EV charging stations -city to provide EV charging units), . Install concrete footings/pads for the EV charging stations, . Setup 2x Level 2 EV charging stations, . Obtain & pass inspections with City inspectors and client department. 2 LUMP 1 Payment & Performance Bond $710 SUM 3 Lot 1 16 HOURS OF ALLOWANCE for as-needed after-$544 hours work. Additional cost thereafter will be assessed at the rate of $34/hour. Subject to prior written approval by city. TOTAL* $36,754 *Includes taxes, fees, expenses and all other costs. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 8 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B I I L I DIR#1000007128 exp. 06/30/2026 CSL #219097 exp. 06/30/2026 SATURN ��:;;:e:__L· e c t r i c SLBE# 14SE1044 City of San Diego -Small Local Business Enterprise SBA(MICRO)#20358 DGS California Department of General Services SB-PW#20358 DGS California Department of General Services Hello, Proposal Carlsbad Public Works EV Charger Installation 5950 El Camino Real, Carlsbad, CA 92008 5-27-2025Revised 7-8-2025 PWM26-389SFAC Exhibit "B" (Cont.) #13825800 We propose to furnish the necessary labor, material, and tools for the electrical project as detailed herein: ......... $35,500.00 Adder for afterhours work (16 hours) -$544.00 • If additional time is needed after hours, the rate difference will be $34.00 an hour charged on time and material.Adder for payment and performance bond -$710.00 SCOPE OF WORK: 1.Install electrical in accordance with "CMWD -Electric Vehicle Charging Stations" electricaldrawings E-001 thru E100. 2.Trench, backfill, install conduits and conductors.3.Install concrete footings/pad for the chargers. 4.Install and set up 2 EV charging stations (city to provide chargers). CLARIFICATIONS: 1.This proposal is based on a standard forty ( 40) hours, (5) day workweek.2.Prevailing wage is included. 3.Electrical chargers are to be provided by the customer.4.A shutdown of the building power will be needed. 5.All appropriate arc flash and safety equipment will be utilized when working on site.EXCLUSIONS: 1.Any pre-existing or unforeseen conditions.2.Permits, utility fees, or charges. 3.Cutting, removal, patching concrete/ AC in the parking lot.4.Temporary power. 5.Parking lot painting and restriping. We are looking forward to serving your best interest on this project. If you should have any further questions or comments, please do not hesitate to call us. Respectfully Submitted, Matthew Robinson 7552 Trade Street • San Diego, CA 92121 • Ph (858) 271-4100 • Fax [858] 271-0230 www.saturnelectric.com • Electrical Contractors Lie. 219097 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B CONDUIT CAP-OFF MIN. 3/4"C- HOMERUN TO PANELBOARD RACEWAY TURNED DOWN 1/2"C, 2#12 AND 1#12 GND - TYPICAL U.N.O. RACEWAY TURNED UP 1/2"C, 2#12 AND 1#12 GND - TYPICAL U.N.O. RACEWAY CONCEALED IN WALL OR CEILING 1/2"C, 2#12 AND 1#12 GND - TYPICAL U.N.O. CONDUIT ROUTED EXPOSED A AMPERE AB ABOVE BACK SPLASH ADA AMERICANS W/DISABILITIES ACT A.F.F. ABOVE FINISHED FLOOR AF ARC FAULT AHU AIR HANDLING UNIT AMP FUSE AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM ARCH'L ARCHITECTURAL AS AMP SWITCH ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BC BARE COPPER BLDG BUILDING BLDG C CONDUIT CAB CABINET CAT CATALOG/CATEGORY CB CIRCUIT BREAKER CKT CIRCUIT CLG CEILING CO CONDUIT ONLY CC COMM COMMUNICATION CU COPPER CTEP CALIFORNIA TYPE EVALUATION PROGRAM DEMO,(D) DEMOLITION/DEMOLISH DISC. DISCONNECT DN DOWN DWG DRAWING EA EACH EF EXHAUST FAN EG EQUIPMENT GROUND ELEC. ELECTRICAL ELEV ELEVATOR EM EMERGENCY EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT (E) EXISTING TO REMAIN EVCS ELECTRICAL VEHICLE CHARGING STATION FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS FF FINISHED FLOOR FIXT FIXTURE FLA FULL LOAD AMPS FLEX FLEXIBLE METALLIC CONDUIT (STEEL) FLUOR FLUORESCENT FT FEET OR FOOT GFA GROUND FAULT ALARM GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HP HORSEPOWER HVAC HEATING, VENTILATING & AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE IMC INTERMEDIATE METAL CONDUIT IN INCH(ES) IRC INTERNATIONAL RESIDENTIAL CODE ISC SHORT CIRCUIT AMPERES JB, J-BOX JUNCTION BOX KCMIL& MCM THOUSAND CIRCULAR MILS KVA KILOVOLT AMPERE KW KILOWATT LCP LIGHTING CONTROL PANEL LRA LOCK RUNNING AMPS LOTO LOCK OUT TAG OUT LTG LIGHTING MAX. MAXIMUM MCA MAXIMUM CIRCUIT AMP MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MECH. MECHANICAL MIN. MINIMUM MLO MAIN LUGS ONLY MTD MOUNTED NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NECA NATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATION NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEUT NEUTRAL NFC NATIONAL FIRE CODE NF NON-FUSIBLE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NTS NOT TO SCALE OCPD OVER CURRENT PROTECTION DEVICE P POLE PH PHASE PNL PANEL PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE PWR POWER QTY QUANTITY (R) RELOCATE RECEP RECEPTACLE REQ'D REQUIRED RGS RIGID GALVANIZED STEEL RSC RIGID STEEL CONDUIT SCHED SCHEDULE SECT SECTION SP SINGLE POLE SN SOLID NEUTRAL SPEC SPECIFICATION SW SWITCH SWBD SWITCHBOARD SWGR SWITCH GEAR SYS SYSTEM TEMP TEMPORARY TELE TELEPHONE T-STAT THERMOSTAT TTB TELEPHONE TERMINAL BACKBOARD TTC TELEPHONE TERMINAL CABINET TYP. TYPICAL UBC UNIFORM BUILDING CODE UL UNDERWRITERS LABORATORY U.N.O. UNLESS NOTED OTHERWISE V VOLT OR VOLTAGE VA VOLT AMPERE VD VOLTAGE DROP VFD VARIABLE FREQUENCY DRIVE VP VAPOR PROOF W WATT, WIRE WP WEATHERPROOF, NEMA 3R XFMR TRANSFORMER - A - - B - - C - - D - - E - - F - - G - - H - - I - - J - - K - - L - - M - - N - - O - - P - - Q - - R - - S - - T - - U - - V - - W - - X - WIRING MISCELLANEOUS LIGHTING SIGNALPOWER 2022 CALIFORNIA ELECTRICAL CODE (CEC) PART 3, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2020 NATIONAL ELECTRICAL CODE (NEC) NFPA 70 2022 CALIFORNIA ADMINISTRATIVE CODE (CAC) PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA BUILDING CODE (CBC) PART 2, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA PLUMBING CODE (CPC) PART 5, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA ENERGY CODE (CEC) PART 6, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA FIRE CODE (CFC) PART 9, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA GREEN BUILDING CODE (CGBC) PART 11, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) APPLICABLE CODES REVISION SYMBOL FEEDER SCHEDULED EQUIPMENT KEYNOTE PLAN SYMBOL # SHEET UNIT # 1 MECHANICAL EQUIPMENT TAG DIAGRAM TAG 1 FIRE ALARM 1 CONDUIT ROUTED UNDER FLOOR/UNDERGROUND DEMOLITION KEYNOTE PLAN SYMBOL ELECTRICAL SYMBOL LIST STANDARD ABBREVIATIONS PUSH BUTTON CONTROL STATION DUAL CHANNEL RACEWAY WITH COVER, DUPLEX AND DATA RECEPTACLES AS NOTED JUNCTION BOX JUNCTION BOX - FLUSH FLOOR MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT SWITCH (WITH SEALTITE RACEWAY CONNECTION FUSED DISCONNECT SWITCH MOTOR CONTROLLER OR STARTER METER SERVICE PEDESTAL SWITCHBOARD OR DISTRIBUTION BOARD LIGHTING AND APPLIANCE PANELBOARD - FLUSH MOUNT LIGHTING AND APPLIANCE PANELBOARD - SURFACE MOUNT PULLBOX - EXTERIOR OR INTERIOR AS INDICATED COMBINATION POWER / DATA FLOOR OUTLET AS INDICATED POWER FLOOR OUTLET WITH DEVICE AS INDICATED DUPLEX RECEPTACLE NEMA 5-20R, 15A, 125V - FLUSH MOUNT CEILING DEDICATED DUPLEX RECEPTACLE, NEMA 5-20R, 20A, 125V RATED MOUNT CENTER OF OUTLET AT 18" AFF UON DUPLEX RECEPTACLE / HALF-SWITCHED "C" INDICATES CONTROLLED VIA MOTION SENSOR/TIME CLOCK, MOUNT CENTER OF OUTLET AT 18" AFF UON QUADPLEX RECEPTACLE, NEMA 5-15R, 20A, 125V, MOUNT CENTER OF OUTLET AT 18" AFF UON DUPLEX RECEPTACLE, NEMA 5-15R, 20A, 125V RATED, MOUNT CENTER OF OUTLET AT 18" AFF UON SINGLE RECEPTACLE, NEMA 5-15R, 20A, 125V, MOUNT CENTER OF OUTLET AT 18" AFF UON PB J J ATS F J JUNCTION BOX - WALL MOUNT SPECIAL RECEPTACLE 480V RATED w/GROUND AS NOTED DUPLEX RECEPTACLE NEMA 5-20R, 15A, 125V GFCI TYPE, MOUNTED 6" ABOVE COUNTER SPLASH C VARIABLE FREQUENCY DRIVEVFD COMBINATION USB/DUPLEX NEMA 5-15R, 125V, MOUNTED 18" AFF UON DUPLEX RECEPTACLE NEMA 5-15R 125V RATED MOUNTED 6" ABOVE COUNTER SPLASH SPECIAL RECEPTACLE. 250V RATED WITH GROUND AS NOTED M SINGLE MANUAL MOTOR RATED SWITCH (1HP) COMBINATION USB/DUPLEX NEMA 5-15R, 125V, MOUNTED 6" ABOVE COUNTER DEDICATED DUPLEX RECEPTACLE, NEMA 5-20R, 20A, 125V, GFCI TYPE, RATED MOUNT CENTER OF OUTLET AT 18" AFF UONG DUPLEX RECEPTACLE NEMA 5-20R, 15A, 125V - FLUSH MOUNT CEILING COMBINATION POWER / DATA FLOOR OUTLET NOTED SUITABLE FOR CONCRETE FLOORS NOTED SUITABLE FOR TYPE 5 CONSTRUCTION DUCT MOUNTED SMOKE DETECTOR WALL MOUNTED FIRE ALARM HORN SPEAKER DEVICE "CD" INDICATES CANDELA; "db" INDICATES DECIBEL LEVEL FLOW SWITCH TAMPER SWITCH ELECTROMAGNETIC DOOR HOLDERDH FIRE ALARM CONTROL PANEL 120VFACP FIRE ALARM SMOKE DETECTOR DEVICE HEAT DETECTOR DD FIRE ALARM PULL STATION COMBINATION FIRE SMOKE DAMPER FIRE ALARM ANNUNCIATORANN FS TS 75cd 30cd WALL MOUNTED HORN STROBE DEVICE "cd" INDICATES CANDELA; "db" INDICATES DECIBEL LEVEL SD WALL MOUNTED STROBE DEVICE "cd" INDICATES CANDELA CEILING MOUNTED STROBE DEVICE "CD" INDICATES CANDELA 15cd CO CARBON MONOXIDE DETECTOR FIRE ALARM BELL MOUNTED +90"A.F.F. PER NFPA72 18.4.8.1 FIRE ALARM TERMINAL CABINETFATC CSFD UTILITY COMPANY SERVICE CABLE TERMINATION CIRCUIT BREAKER FUSE FUSED DISCONNECT SWITCH SWITCH TRANSIENT VOLTAGE SURGE SUPPRESSOR CURRENT TRANSFORMER (CT) POTENTIAL TRANSFORMER GROUNDING ELECTRODE UTILITY COMPANY POWER METER MOTOR (# INDICATED HP) GENERATOR MOTOR GROUND FAULT PROTECTION DEVICE TRANSFER SWITCH ATS OR MTS AND NUMBER OF POLES AS NOTED ENCLOSED CIRCUIT BREAKER RELAY CONTACTOR (NORMALLY OPEN) CONTACTOR (NORMALLY CLOSED) CONTROL SWITCH PUSH BUTTON R N EM L M G TVSS # M CUSTOMER OWNED POWER METER T AC-1 GFPD PENDANT FIXTURE LED WALL SCONCE PHOTOCELL LIGHTING CONTACTOR OCCUPANCY SENSOR - WALL MOUNTED OCCUPANCY SENSOR - CEILING EXIT SIGN - CEILING MOUNTED (SHADE INDICATES FACE) BOLLARD LIGHT FIXTURE PARKING LOT POLE MOUNTED LIGHT FIXTURE MONO-POINT LIGHT FIXTURE LED WALL WASHER LED WALL MOUNTED LIGHT FIXTURE LED DOWNLIGHT RECESSED OR SURFACE LINEAR LED STRIP FIXTURE LED WALL MOUNT FIXTURE LINEAR LED FIXTURE SUSPENDED OR PENDANT LINEAR LED FIXTURE RECESSED MOUNT LC PC EXIT SIGN - WALL MOUNTED (SHADE INDICATES FACE) EXIT SIGN - W/ARROWS INDICATE DIRECTION OS OS OCCUPANCY SENSOR w/DIMMER- WALL MOUNTEDOSD 2,3,4 WALL SWITCH, +48" OR AS NOTED: SUBSCRIPTS AT SYMBOL INDICATE THE FOLLOWING: abcd 2 - DOUBLE POLE (20A, 120/277V) 3 - THREE WAY (20A, 120/277V) 4 - FOUR WAY (20A, 120/277V) K - KEY OPERATED (20A, 120/277V) P - PILOT LIGHT (20A, 120/277V) R - REMOTE CONTROL SWITCH (20A, 120/277V) M - MOTOR STARTING SWITCH (20A, 120/277V) T - TIMER SWITCH (0-60 MIN.) (20A, 120/277V) LIGHTING CONTROL POWER PACKPP LIGHTING FIXTURE NOTATION A, 1, b INDICATES: A = FIXTURE TYPE, REFER TO SCHEDULE 1 = CIRCUIT NUMBER b = SWITCH CONTROLLING FIXTURE ab =BI-LEVEL/DUAL SWITCH CONTROL HALF SHADED LINEAR LED OR SOLID DOWNLIGHT FIXTURE FURNISHED ON EMERGENCY POWER. 1b A D - DIMMER SWITCH (20A, 120/277V) D,K EMERGENCY BUG EYE FIXTURE WITH 90 MIN BATTERY BACKUP THERMOSTAT OUTLET AT +54" (HVAC UNIT DESIGNATION) F05 1. SYMBOLS ARE NOT NECESSARILY USED IN THIS PROJECT. 2. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE ENGINEER RESERVES THE RIGHT TO ALLOW OTHER METHODS AND MATERIALS NOT REFLECTED HEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE TO REQUEST THE ENGINEER WAIVE THE STANDARDS TO ALLOW ALTERNATE MEANS AND METHODS PRIOR TO BEGINNING THE PROJECT. CONTRACT DOCUMENT REVISIONS TO ACCOMMODATE INSTALLED CONDITIONS, WITHOUT PRIOR APPROVAL, WILL RESULT IN ADDITIONAL DESIGN CHARGES TO THE CONTRACTOR. 3. ELECTRICAL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH THE NECA INSTALLATION STANDARDS TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. 4. WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE CURRENTLY ACCEPTED EDITION OF APPLICABLE NATIONAL, STATE AND CITY CODES AND ORDINANCES. 5. ELECTRICAL SYSTEM COMPONENTS SHALL BE LISTED OR LABELED BY UL OR OTHER RECOGNIZED TESTING FACILITY AS ALLOWED BY AUTHORITY HAVING JURISDICTION. 6. WHERE AN APPARENT DISCREPANCY EXISTS BETWEEN THE REQUIREMENTS OF THE GENERAL NOTES AND INFORMATION PORTRAYED IN THE ELECTRICAL DRAWINGS, THE CONTRACTOR SHALL INCLUDE IN HIS BID THE COST OF THE GREATER QUALITY OR QUANTITY. 7. CONTRACTOR SHALL VISIT JOB SITE PRIOR TO BID AND VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL INCLUDE IN BASE BID COSTS REQUIRED FOR PERMITS AND INSPECTIONS. 8. CONTRACTOR SHALL VERIFY, WITH OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING BID, ALLOWABLE WORKING HOURS, EMPLOYEE PARKING AREAS, MATERIAL DELIVERY, STORAGE REQUIREMENTS, DEMOLITION AND REMOVAL OF CONSTRUCTION DEBRIS, AS WELL AS DAILY CLEAN UP REQUIREMENTS. INCLUDE COSTS IN BID FOR DUST BARRIERS, DUMPSTERS ETC. AS REQUIRED FOR THE DURATION OF THE PROJECT. PERFORM WORK AS DIRECTED BY OWNER'S REPRESENTATIVE AND ARCHITECT. 9. ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE NECESSARY CORRECTIONS. 10. CONTRACTOR SHALL GUARANTEE WORK AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY CORRECTED BY CONTRACTOR WITHOUT ADDITIONAL CHARGE TO OWNER. 11. DO NOT SCALE ELECTRICAL DRAWINGS. VERIFY EXACT LOCATION OF ALL DEVICES, JUNCTION BOXES, LIGHTING FIXTURES, WITH ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS PRIOR TO INSTALLATION. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL EQUIPMENT AND OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR TO ROUGH-IN. EVERY OUTLET HEIGHT SHALL BE VERIFIED ON EACH WALL WITH THE INTERIOR PLANNING AND DESIGN DRAWINGS. COORDINATE WITH CABINET SHOP DRAWINGS TO ENSURE PROPER HEIGHT AND LOCATION WITH RESPECT TO MILLWORK, EQUIPMENT. 12. RACEWAY SYSTEMS ARE SHOWN DIAGRAMMATICALLY. ACTUAL LOCATION AND ROUTING SHALL BE DETERMINED BY CONTRACTOR TO SUIT FIELD CONDITIONS. 13. MINIMUM RACEWAY SIZE SHALL BE 3/4"". MINIMUM HOMERUN SIZE SHALL BE 3/4". MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG U.N.O. TYPICAL. POWER RELATED CONDUITS SHALL HAVE A CODE SIZE GROUND WIRE INSTALLED IN EACH RUN. 14. CONTRACTOR SHALL PROVIDE RACEWAY SYSTEMS INDICATED ON THE DRAWING PER CEC REQUIREMENTS AND GENERAL NOTES. ANY DEVIATION FROM THE WIRING METHODS INDICATED SHALL BE ALLOWED ONLY BY SPECIFIC WRITTEN APPROVAL FROM EITHER THE ARCHITECT, ENGINEER OR OWNER. CONTRACTOR'S BID SHALL INCLUDE COSTS FOR RACEWAY SYSTEMS AS SPECIFIED UNLESS SPECIFIC WRITTEN APPROVAL FOR AN ALTERNATIVE WIRING METHOD IS OBTAINED FROM EITHER THE ARCHITECT, ENGINEER OR OWNER AND IS SUBMITTED AS PART OF CONTRACTOR'S FORMAL BID PROPOSAL. 15. PRIOR TO INSTALLATION, CONTRACTOR SHALL REVIEW THE COMPLETE SET OF CONSTRUCTION DOCUMENTS FOR CONFLICTS WITH OTHER TRADES. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT DURING INSTALLATION. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS IN EQUIPMENT LOCATION AND ROUTING AS NECESSARY. 16. CONTRACTOR SHALL BE RESPONSIBLE TO PROPERLY CUT AND PATCH EXISTING CONSTRUCTION AS REQUIRED TO INSTALL NEW ELECTRICAL WORK PATCHING SHALL BE OF THE SAME MATERIALS, WORKMANSHIP AND FINISH AS THE EXISTING WORK AND SHALL ACCURATELY MATCH SURROUNDING WORK TO THE SATISFACTION OF THE ARCHITECT. 17. ELECTRICAL EQUIPMENT SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS TO ACCOMMODATE QUANTITY AND SIZE OF CONDUCTORS REQUIRED. CONTRACTORS SHALL PROVIDE EQUIPMENT WITH OVERSIZED ENCLOSURES WHERE REQUIRED. 18. NEW SWITCHBOARDS SHALL HAVE LOCKING DOORS AND BE KEYED THE SAME U.N.O. 19. PROVIDE TYPE WRITTEN UPDATED PANEL DIRECTORY TO BE MOUNTED ON INSIDE OF PANEL DOOR COVERS. DIRECTORY SHALL REFLECT ADDITIONS OR MODIFICATIONS TO EXISTING PANELS AND SHALL REFLECT ACTUAL "AS-BUILT" CONDITIONS. 20. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW OF THE FOLLOWING EQUIPMENT: a. ELECTRICAL SWITCHGEAR: SWITCHBOARDS, WITH PANELS, MOTOR CONTROL b. OVERCURRENT DEVICES: CIRCUIT BREAKERS AND FUSES INCLUDING c. TIME/CURRENT TRIP CURVES. d. LIGHT FIXTURES, WIRE DEVICES, CONDUIT & CONDUCTORS. e. MOTOR DISCONNECT SWITCHES AND ASSOCIATED STARTERS. 34. EQUIPMENT ELECTRICAL TERMINATIONS TO UNDERGO A TORQUE TEST. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MANUFACTURER'S RECOMMENDED TORQUE DOCUMENTATION AND TOOLS TO PERFORM TORQUE TEST. 35. UNDERGROUND SERVICE CONDUITS SHALL BE SEALED PER CEC ARTICLE 230-8. 36. ELECTRICAL EQUIPMENT SHALL BE MOUNTED ON A 6" HIGH CONCRETE PAD. 37. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 38. CONTRACTOR SHALL REPAIR ANY DAMAGED IRRIGATION LINES TO MATCH EXISTING CONDITIONS. FIELD VERIFY AND COORDINATE PRIOR ANY EXCAVATION WORK. GENERAL ELECTRICAL NOTES E-001 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS E-002 ELECTRICAL SPECIFICATIONS & SITE PLAN E-003 SINGLE LINE DIAGRAM E-100 PARTIAL ELECTRICAL SITE PLAN & DETAILS SHEET INDEX E-001 JS BK SC GENERAL ELECTRICAL LEAD SHEET "AS BUILT" DATE INSPECTOR DATE CMWD - ELECTRIC VEHICLE CHARGING STATIONS REVIEWED BY: IM P R O V E M E N T P L A N S - C I T Y O F C A R L S B A D - F I R E S T A T I O N N O . 1 S W I T C H B O A R D R E P L A C E M E N T FO LCAI R SI EG NE C No. E22808 LTA S E TE ITREC E S ETR V TE INAAL F O R I G N E R N EE RDP FO E SSIO L NA N LCO IL S M. Exp. 06-30-25 DATE SIGNEDDATE SIGNED 06/05/24 60% DESIGN PHASE01/15/25 BNK 1 PETERS CANYON ROAD, SUITE 130 IRVINE, CA. 92606 TEL: 949-387-8500, FAX: 949-387-0800 IDS IDS GROUP Project # 22X005.06 5950 EL CAMINO, CARLSBAD, CA 92008 90% DESIGN PHASE02/14/25 BNK 100% CD-ISSUE TO PLAN CHECK02/27/25 BNK PWM26-3895FAC Exhibit "B" (Cont.) Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B rn • "O 00 ID ~ 0 z 0 L ID C ID C) 0 0 I w ~ ui 0 0 X N , u ID w "' 3-0 .,: (.) "' 0 / ~ 0 0 z ff> z 0 c= ;"' ff> C) z u "' .,: I (.) > w f---(.) ti' f- ff> i5 "' F" .,: 3 _J .,: (L u z ::J " 0 .,: m ff> _J "' .,: (.) ~ "' 0 0 X N N / "O ~ 0 .c ;'.), N N 0 N / fl' (.) w , 0 "' ~ ff> E o_ N ,:-; N 0 "' N 0 N "' N >-L 0 ' L _Q ID c_ ~ 0 0 I w 0 .c "" ID ff> ID ID i7i t:~""':"'~----------- j na~~m _Q 0 m >, m "O ID ~ ~ 0 ii: DIAL BEFORE YOU DIG TWO WORKING DAYS BEFORE YOU DIG TOLL FREE --1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT □CJ - --0 ---0 D $ $ □ {] 0 □ 0 □ I I I I I I D D D ~ 0 @ 0 D -e =(c:) =8 =8 =e =El ~ =t 1-0 1-{;J) § § ~ l<P> VI ll@IVII =@ =§I: 0 f() { [Q] r I I I I I □ ----- l?::f01«l □ □ II""] f--0 $ QJ QJ ~ ---- /'- ~ ~ -----fl,_ ------j I < f--- ------rr:::::n- ---0~ -----0'&------ __c-0 0---- -- -ffi J__, rr _L ~ - 0 0 □ 0 I 7 M -H- -+- .---: _L . . 0 12'..s:J □ e 8 0 ◊ 6 C) • • • • • • • • • P.E. EXP. ~ I ===~~=====t=~=========-=-=-=--_-_-_-_-_-_-_--====~t=====+=~====r~=====t=~~~ ~I S~HE~ET~l~C~IT~Y~O=F=C=A~R~L~S~B~A=D~I =SH=EE=::!TS I f-PUBLIC WORKS DEPARTMENT IMPROVEMENT PLANS FOR: * l~=E=j~==========l=l=f=f==l I-~AAIP~P~RfcO)IV/EE:CD~: ===========~:=:====== JOHN MAASHOF P.E. C61909 EXPIRES 09 /30 /25 ENGINEER DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL OTHER APPROVAL DATE INITIAL CITY APPROVAL OWN BY: CHKD BY: RVWD BY: PROJ~CT NO. _ I DRAWING NO. "AS BUILT" DATE INSPECTOR DATE CMWD - ELECTRIC VEHICLE CHARGING STATIONS REVIEWED BY: IM P R O V E M E N T P L A N S - C I T Y O F C A R L S B A D - F I R E S T A T I O N N O . 1 S W I T C H B O A R D R E P L A C E M E N T 60% DESIGN PHASE01/15/25 BNK 1 PETERS CANYON ROAD, SUITE 130 IRVINE, CA. 92606 TEL: 949-387-8500, FAX: 949-387-0800 IDS IDS GROUP Project # 22X005.06 5950 EL CAMINO, CARLSBAD, CA 92008 90% DESIGN PHASE02/14/25 BNK 100% CD-ISSUE TO PLAN CHECK02/27/25 BNK A.MATERIALS 1. MATERIALS SHALL BE NEW AND OF QUALITY AS SPECIFIED ON THE PLANS OR SPECIFICATIONS AND MUST CARRY THE UNDERWRITER'S LABORATORIES APPROVAL COVERING THE PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. B.CONDUIT 1. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC CONDUIT EXCEPT AS PERMITTED BELOW. RGS, WITH A 20 MIL PVC COATING WILL BE USED WHEN IN CONTACT WITH EARTH. IMC IS NOT PERMITTED. EMT SHALL BE USED FOR INDOOR LOCATIONS NOT IN CONTACT WITH EARTH, NOT IN CONCRETE SLABS OR WALLS AND NOT SUBJECT TO DAMAGE. PVC MAY BE USED IN OR BELOW CONCRETE AND DIRECT BURIED IN EARTH. FLEXIBLE STEEL CONDUIT SHALL BE USED FOR INDOOR FINAL CONNECTIONS TO EQUIPMENT IN LENGTHS NOT TO EXCEED 72". LIQUID-TIGHT FLEXIBLE STEEL CONDUIT SHALL BE FOR OUTDOOR FINAL CONNECTIONS TO EQUIPMENT NOT TO EXCEED 36". 2. WHERE CONDUIT ENTERS OUTLET BOXES, FIXTURES OR CABINETS, FIRMLY FASTEN WITH STEEL SET SCREW, COMPRESSION CONNECTORS, OR DOUBLE LOCKNUTS FOR GRC. CONNECTIONS SHALL HAVE BUSHINGS OR INSULATED THROAT CONNECTORS. FIRMLY FASTEN CONDUIT TO THE BUILDING CONSTRUCTION. RUN EXPOSED CONDUIT PARALLEL TO THE BUILDING LINES, SUPPORTED BY APPROPRIATE HANGERS (UNISTRUT, T & B OR APPLETON, OR EQUAL). 3. COVER METALLIC CONDUIT IN CONTACT WITH EARTH WITH POLYETHYLENE TAPED SPIRAL WRAPPED, 1/2 LAPPED TO PROVIDE 20 MIL. THICKNESS. TAPE SHALL BE SCOTCH NO. 50 TAPE. CONDUIT AND DUCTS NOT UNDER BUILDINGS AND FEEDER DUCTS SHALL BE INSTALLED PER N.E.C. 300-5. MAKE JOINTS WITH COMPOUND TO BE WATERTIGHT. 4. FITTINGS AND CONDUIT BODIES SHALL BE STEEL. NO DIECAST FITTINGS. 5. CONDUIT SIZES SHALL BE AS REQUIRED BY CODE AND AS INDICATED OR SPECIFIED. 6. EMPTY CONDUIT SYSTEMS SHALL HAVE A NYLON PULL STRING TO FACILITATE INSTALLATION OF FUTURE WIRE. 7. SCHEDULE 40 PVC CONDUIT SHALL BE PERMITTED UNDERGROUND WITH PROPER FITTINGS, UL APPROVED AND CEMENTED JOINTS. PENETRATIONS THROUGH FLOOR SLABS AND BENDS GREATER THAN 22° SHALL BE WRAPPED RIGID GALVANIZED STEEL ELBOWS. 8. CONDUITS AND OUTLETS SHALL BE CONCEALED WITH THE BUILDING STRUCTURE, EXCEPT THAT CERTAIN MOTOR AND LIGHTING FEEDER CONDUITS MAY BE RUN EXPOSED IN CERTAIN AREAS AS INDICATED ON THE DRAWINGS. CONDUIT SHOWN TO BE INSTALLED IN CABINETS, COUNTERS, AND CASEWORK SHALL BE RUN AS DIRECTED BY THE ARCHITECT. 9. CONDUIT SYSTEMS SHALL HAVE A CODE SIZED COPPER GROUND CONDUCTOR INCREASE CONDUIT SIZE AS REQUIRED. 10. CONDUIT PENETRATION THROUGH ROOF SHALL HAVE ROOF FLASHING WITH CAULK TYPE COUNTER FLASHING SLEEVE. INSTALLATION SHALL BE WATERTIGHT. 11. CONDUITS SHALL BE ROUTED SURFACE ON THE STRUCTURE, PARALLEL AND PERPENDICULAR TO THE STRUCTURE. C.OUTLET, PULL, AND JUNCTION BOXES 1. EACH SWITCH, LIGHT. RECEPTACLE OR OTHER OUTLET SHALL BE PROVIDED WITH A CODE GAUGE, GALVANIZED STEEL OUTLET BOX. JUNCTION AND PULL BOXES SHALL BE CODE GAUGE, GALVANIZED STEEL. OUTLET BOXES SHALL BE OF THE ONE PIECE, KNOCKOUT TYPE, IN GENERAL 4" SQUARE WITH PLASTER RING. PLASTER RINGS SHALL BE SET TO PROVIDE NOT MORE THAN 1/8" FROM WALL SURFACE TO RING. IN NO CASE SHALL PLASTER RING PROJECT BEYOND SURFACE OF WALL. SINGLE GANG RINGS SIMILAR TO STEEL CITY 52050 SHALL BE USED FOR 4" BOXES IN UNFINISHED BRICK NUMBER 180 BOXES MAY BE USED FOR UNFINISHED MASONRY FLUSH WALL OUTLETS. CENTER OUTLET BOXES IN BLOCK COURSE. 2. BOXES INSTALLED IN POURED CEMENT FLOORS SHALL BE FLUSH TYPE CAST IRON OR STEEL WITH WATERTIGHT GASKETED COVERS. WHERE BOXES ARE INSTALLED IN FLOORS WITH TILE OR CARPET FLOOR COVERING, COVERS SHALL BE OF THE RECESSED TYPE TO ACCOMMODATE THE FLOOR COVERING. 3. BOXES INSTALLED FOR THE ALARM, COMPUTER, AND SECURITY SYSTEM SHALL BE PROVIDED WITH APPROPRIATE COVER PLATES. 4. BOXES FOR TELEPHONE, COMPUTER, T.V., FIRE ALARM, SECURITY, AND SIMILAR SYSTEMS SHALL BE MINIMUM 4" SQUARE AND 2-1/8" DEEP. D.SWITCHBOARDS 1. SWITCHBOARDS SHALL BE PROVIDED WITH FULLY RATED COPPER OR ALUMINUM BUS. HORIZONTAL TAPERED BUSSING SHALL NOT BE ALLOWED. 2. ACCEPTABLE MANUFACTURERS - CUTLER HAMMER, SEIMENS, SQUARE D OR APPROVED EQUAL. 3. FACTORY ASSEMBLED DEAD FRONT, METAL ENCLOSED, AND SELF-SUPPORTING SWITCHBOARD ASSEMBLY CONFORMING TO NEMA PB 2, AND UL 891, AND COMPLETE FROM INCOMING LINE TERMINALS TO LOAD SIDE TERMINATIONS. 4. LINE AND LOAD TERMINATIONS: ACCESSIBLE FROM THE FRONT ONLY OF THE SWITCHBOARD. SUITABLE FOR THE CONDUCTOR MATERIALS AND NUMBER OF CONDUCTORS USED. 5. BUS CONNECTIONS: BOLTED. ACCESSIBLE FROM FRONT FOR MAINTENANCE. PROVIDE BELLEVILLE WASHERS FOR AND PROPERLY TORQUE CONNECTIONS. 6. PROVIDE FULLY-RATED NEUTRAL BUS AND FULLY RATED GROUND BUS MATCHING MATERIAL USED FOR MAIN BUS. 7. FUTURE PROVISIONS: FULLY EQUIP SPACES FOR FUTURE DEVICES WITH BUSSING AND BUS CONNECTIONS. SUITABLY INSULATED AND BRACED FOR SHORT CIRCUIT CURRENTS. CONTINUOUS CURRENT RATING AS INDICATED ON DRAWINGS. E.PANEL BOARDS 1. CIRCUIT BREAKER TYPE AS INDICATED ON DRAWINGS. UNLESS INDICATED OTHERWISE, PANELS SHALL HAVE PANEL BOARD TYPE CONSTRUCTION WITH BOLT-ON CIRCUIT BREAKERS FOR 3Ø PANELS. MANUFACTURERS SHALL BE SIEMENS WITH VOLTAGE, SIZES, AND RATINGS AS INDICATED ON DRAWINGS. 2. THE CIRCUIT BREAKERS SHALL BE OPERABLE IN ANY POSITION AND BE REMOVABLE FROM THE FRONT OF THE PANEL BOARD WITHOUT DISTURBING THE ADJACENT UNITS. BRANCH BREAKERS SHALL BE OF SUCH DESIGN THAT COMBINATION OF SINGLE-POLE, DOUBLE-POLE, AND THREE-POLE BREAKERS CAN BE ASSEMBLED ON THE SAME PANEL. EACH BRANCH CIRCUIT SHALL BE CLEARLY NUMBERED. BRANCH AND MAIN TERMINALS SHALL BE OF THE SOLDERLESS TYPE. HANDLE TIES TO FORM MULTI-POLE BREAKERS NOT ACCEPTABLE. 3. WIRE TERMINATION FOR PANEL BOARDS AND CIRCUIT BREAKERS SHALL BE LISTED AS SUITABLE FOR 75 DEGREES C. 4. PROVIDE A TYPEWRITTEN CIRCUIT INDEX BEHIND CLEAR PLASTIC COVER ON INSIDE OF DOOR. INFORMATION SHALL INCLUDE ROOM AND TYPE LOAD SERVED. CIRCUIT BREAKERS SHALL BE IDENTIFIED, INCLUDING SPARES. INDEX CARD FRAME SHALL BE METAL, SECURED TO DOOR. 5. WHERE PANEL BOARDS ARE INSTALLED FLUSH WITH THE WALLS, EXTEND EMPTY CONDUITS FORM THE PANEL BOARD TO AN ACCESSIBLE SPACE ABOVE OR BELOW. PROVIDE 3/4" (MINIMUM SIZE) CONDUIT FOR EVERY THREE SINGLE SPARE CIRCUIT BREAKERS OR SPACE OR EQUIVALENT MULTI-POLE ARRANGEMENT, OR FRACTION THEREOF, BUT NOT LESS THAN TWO CONDUITS FOR EACH PANEL. 6. PANEL BOARDS TO BE PROVIDED WITH COPPER BUSSING ONLY. 7. LOAD CENTERS SHALL NOT BE ALLOWED UNLESS NOTED OTHERWISE. 8. NEW PANELBOARDS SHALL COMPLY WITH NEC ARTICLE 110.16. EQUIPMENT MANUFACTURERS SHALL PROVIDE WARNING LABELS FOR PANELBOARDS, GENERATORS, AUTOMATIC TRANSFER SWITCHES TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICE, OR MAINTENANCE OF THE EQUIPMENT. F.WIRE 1. CONDUCTOR SIZES SHOWN ON THE DRAWINGS ARE BASED ON COPPER WIRE. UNLESS OTHERWISE SPECIFIED, WIRE SHALL BE TYPE XHHW FOR FEEDERS OR BRANCH CIRCUITS LARGER THAN 4 AWG, TYPE THHN/THWN INSULATION FOR FEEDERS AND BRANCH CIRCUITS 4 AWG AND SMALLER. BRANCH CIRCUIT WIRING SHALL BE COPPER. ALUMINUM WIRING IS PROHIBITED. INCREASE CONDUIT SIZE AS REQUIRED. THE WIRES SHALL BE MARKED WITH COLOR TO SIMPLIFY CIRCUIT IDENTIFICATION. UNLESS OTHERWISE REQUIRED BY LOCAL ORDINANCES GROUND WIRES SHALL BE GREEN, NEUTRAL WIRES SHALL BE 120V- WHITE, 277V- GRAY, AND LIVE WIRES 208Y/120V AND 120/240 SHALL BE BLACK (PHASE A), RED (PHASE B), AND BLUE (PHASE C). FOR 480Y/277V CIRCUITS, THE COLOR CODE SHALL BE BROWN (PHASE A), ORANGE (PHASE B), AND YELLOW (PHASE C). THE WIRE SHALL BE 12 AWG UNLESS OTHERWISE INDICATED. CIRCUIT SHALL BE LABELED IN EACH J-BOX. 2. ALUMINUM WIRE IS NOT PERMITTED FOR USE. 3. NO WIRE SHALL BE INSTALLED IN THE CONDUIT SYSTEM UNTIL THE CONDUIT SYSTEM IS COMPLETE. USE MINERALAC NO. 100 OR EQUIVALENT AS A LUBRICANT TO FACILITATE THE INSTALLATION OF THE CONDUCTORS IN THE CONDUIT SYSTEM. 4. SPLICES IN EXTERIOR PULL BOXES AND MANHOLES SHALL BE WEATHERPROOF USING "SCOTCHCAST" SPLICE KIT OR APPROVED EQUAL. SEAL ENDS OF CONDUITS AND DUCTS WITH "DUCTSEAL" OR APPROVED EQUAL. 5. ALL WIRING SHALL BE STRANDED. SOLID WIRE NOT PERMITTED. G.WIRING DEVICES 1. WALL SWITCHES SHALL BE SPECIFICATION GRADE AC SILENT TYPE SWITCHES, 20A, 120/277 VOLT. 2. RECEPTACLES SHALL BE SPECIFICATION GRADE, DUPLEX TYPE, NEMA 5-20R, 20 AMPERE, 120 VOLT GROUNDED TYPE. SPECIAL APPLICATION RECEPTACLES SHALL BE INDICATED ON PLANS. MOUNT WITH THE GROUND DOWN. 3. DEVICE PLATES SHALL BE EQUAL TO SIERRA SMOOTH-LINE PLASTIC WALL PLATES. COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED. 4. RECEPTACLES IN OUTDOOR AND WET LOCATIONS SHALL BE INSTALLED WITH A HINGED OUTLET COVER/ENCLOSURE CLEARLY MARKED AND U.L. LISTED SUITABLE FOR WET LOCATIONS WHILE IN USE, EQUAL TO TAYMAC SPECIFICATION GRADE. H.LIGHTING FIXTURES 1. PROVIDE ALL LIGHTING FIXTURES, WIRED AND CONNECTED. THE DRAWINGS INDICATE THE FIXTURES FOR EACH LOCATION. PROVIDE LAMPS FOR FIXTURES. THE LAMPS SHALL BE BY THE SAME MANUFACTURER. VERIFY CEILING CONSTRUCTION BEFORE ORDERING RECESSED UNITS. PROVIDE PLASTER FRAMES AND HANGERS AS REQUIRED. CEILING CONSTRUCTION, ARCHITECTURAL ACCESSORIES, VOLTAGE, AND BALLASTS TO MEET THE EXISTING CONDITION. J.SERVICE ENTRANCE SECTION 1. THE SERVICE ENTRANCE EQUIPMENT SHALL BE AS INDICATED ON THE DRAWINGS. EQUIPMENT SHALL CARRY THE U.L. LABEL AND SHALL CONFORM TO THE POWER COMPANY REGULATIONS. 2. SERVICE ENTRANCE EQUIPMENT SHALL BE PROVIDED WITH A FULLY RATED COPPER OR ALUMINUM BUS. HORIZONTALLY TAPERED BUSSING SHALL NOT BE ALLOWED. K.SYSTEM GROUNDING 1. GROUNDING SHALL COMPLY WITH REQUIREMENTS OF ARTICLE 250. EXPOSED NONCURRENT CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS, METALLIC CABLE ARMOR, GROUNDING CONDUCTOR OF NONMETALLIC SHEATHED CABLES, GROUNDING CONDUCTOR IN NONMETALLIC RACEWAYS, AND GROUNDED CONDUCTORS OF THE WIRING SYSTEM SHALL BE GROUNDED. 2. GROUNDING CONDUCTOR (NEUTRAL) OF THE WIRING SYSTEM SHALL BE CONNECTED TO THE SYSTEM GROUNDING CONDUCTOR AT A SINGLE PLACE IN EACH SYSTEM BY REMOVABLE BONDING JUMPERS, SIZED ACCORDING TO THE APPLICABLE PROVISIONS OF THE NATIONAL ELECTRICAL CODE. THE GROUNDED CONDUCTOR (NEUTRAL) TO THE GROUNDING CONDUCTOR CONNECTION SHALL BE LOCATED IN THE ENCLOSURE FOR THE SYSTEM'S OVERCURRENT PROTECTION OR WHERE OTHERWISE INDICATED ON THE PLANS OR SPECIFICATIONS. 3. A GROUND BUS SEPARATE FROM THE NEUTRAL BUS SHALL BE PROVIDED IN ALL SWITCHBOARDS AND PANELBOARDS. GROUND BUS SHALL BE RETORQUED (CHECKED) PRIOR TO ENERGIZING EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. 4. GROUND BUSES AND NEUTRAL BUSES IN DISTRIBUTION PANELS, SWITCHBOARDS, PANELBOARDS, AND THOSE PROVIDED IN ANY EQUIPMENT SHALL BE ISOLATED EXCEPT WHERE REQUIRED TO BE CONNECTED AS SPECIFIED ABOVE FOR THE SERVICE ENTRANCE AND IN TRANSFORMER TERMINAL COMPARTMENTS. 5. WHEN INDICATED ON THE DRAWINGS, EQUIPMENT GROUNDING CONDUCTORS SHALL BE EXTENDED FROM THE GROUND BUS IN THE DISTRIBUTION EQUIPMENT TO THE RECEPTACLE, FIXTURE OR DEVICE LUGS WHERE THEY ARE PROVIDED. WHERE LUGS ARE NOT PROVIDED, EQUIPMENT GROUNDING CONDUCTORS SHALL BE CONNECTED TO EQUIPMENT ENCLOSURES. THE CONNECTIONS SHALL BE ARRANGED SUCH THAT REMOVAL OF THE RECEPTACLE, EQUIPMENT GROUND CONDUCTORS, OR GROUND JUMPERS FROM GROUND BUSING SHALL NOT AFFECT THE GROUND SYSTEM. 6. RACEWAYS MAY NOT BE USED AS A GROUNDING CONDUCTOR FOR POWER AND LIGHTING CIRCUITS. CONDUIT SHALL HAVE SEPARATE CODE SIZED GREEN GROUND WIRE INSTALLED IN THE CONDUIT TO INSURE A CONTINUOUS GROUNDING PATH. 7. IN INACCESSIBLE LOCATIONS, MAKE CONNECTIONS BY EXOTHERMIC WELD PROCESS. 8. IN ACCESSIBLE LOCATIONS, CONNECTIONS SHALL BE MADE WITH BOLTED THROUGH, APPROVED SOLDERLESS BRONZE GROUNDING DEVICES. 9. BOND TOGETHER METAL SIDING NOT ATTACHED TO GROUNDED STRUCTURE BOND TO GROUND. L.TELEPHONE SYSTEM 1. TELEPHONE WALL OUTLETS SHALL CONSIST OF STANDARD BOXES MOUNTED 18" ABOVE THE FLOOR UNLESS OTHERWISE INDICATED. CONNECT OUTLETS TO TELEPHONE TERMINAL WITH SEPARATE 3/4" CONDUIT UNLESS OTHERWISE SHOWN ON DRAWINGS. PROVIDE A TERMINAL MOUNTING BOARD FOR THE INCOMING SERVICE CABLE. M.LIGHTING CONTROL 1. FURNISH AND INSTALL TIME SWITCHES, PHOTOCELLS, CONTACTORS AND FULL LIGHTING CONTROL SYSTEMS AS REQUIRED FOR LIGHTING CONTROLS INDICATED ON THE DRAWINGS. 2. TIME SWITCHES SHALL BE EQUAL TO PARAGON, GENERAL ELECTRIC, TORK, OR INTERMATIC AND SHALL HAVE SIZE AND NUMBER OF POLES AS REQUIRED. 3. PHOTOCELLS SHALL BE EQUAL TO TORK OR INTERMATIC WITH VOLTAGE AS INDICATED. N.LIGHTING INVERTER SYSTEM 1. LIGHTING INVERTERS SHALL HAVE A CENTRAL BATTERY AS EMERGENCY POWER SOURCE FOR EGRESS LIGHTING WITH SIZE AND VOLTAGE AS INDICATED ON THE DRAWINGS. 2. ACCEPTABLE MANUFACTURES - DUAL-LITE, HUBBELL LIGHTING, LITHONIA LIGHTING EMERGENCY LIGHTING SYSTEMS, MCPHILBEN EMERGENCY LIGHTING OR APPROVED EQUAL. 3. UNIT SHALL AUTOMATICALLY SENSE LOSS OF NORMAL AC SUPPLY AND USE A SOLID-STATE SWITCH TO TRANSFER LOADS. TRANSFER IN 0.004 SECOND OR LESS FROM NORMAL SUPPLY TO BATTERY-INVERTER SUPPLY. INVERTER SHALL BE COMPATIBLE WITH INCANDESCENT, MAGNETIC AND ELECTRONIC FLUORESCENT BALLASTS, HIGH POWER FACTOR COMPACT FLUORESCENT, AND HIGH INTENSITY DISCHARGE (H.I.D) LAMP TYPES. 4. UNIT SHALL SUPPLY POWER TO OUTPUT CIRCUIT(S) FROM A SINGLE, EXTERNAL, NORMAL SUPPLY SOURCE. UNIT AUTOMATICALLY TRANSFERS LOAD FROM NORMAL SOURCE TO INTERNAL BATTERY/INVERTER SOURCE. RETRANSFER TO NORMAL IS AUTOMATIC WHEN NORMAL POWER IS RESTORED. 5. UNIT SHALL COMPLY WITH NFPA 70 AND NFPA 101. AND BE UL 924 LISTED. 6. UNIT SHALL SUSTAIN A FULL-CAPACITY OUTPUT FOR A MINIMUM OF 90 MINUTES. PROVIDE BATTERIES THAT ARE MAINTENANCE FREE, SEALED LEAD CALCIUM BATTERY WITH AN EXPECTED LIFE OF NO LESS THAN 10 YEARS. 7. UNIT SHALL CONTAIN GROUP DISPLAYS, INDICATIONS, AND BASIC SYSTEM CONTROLS ON COMMON CONTROL PANEL ON FRONT OF CENTRAL BATTERY INVERTER ENCLOSURE. 8. ENCLOSURE SHALL BE STEEL, WITH HINGED LOCKABLE DOORS, SUITABLE FOR FLOOR MOUNTING. MANUFACTURER'S STANDARD CORROSION-RESISTANT FINISH. O.DRY TYPE TRANSFORMERS 1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING a. SIEMENS. 2. CONTINUOUS WINDINGS WITHOUT SPLICES, EXCEPT FOR TAPS. a. INTERNAL COIL CONNECTIONS - BRAZED OR PRESSURE TYPE. b. COIL MATERIAL - COPPER 3. ENCLOSURE - VENTILATED, NEMA 250, TYPE 2 (NEMA 3R FOR OUTDOOR INSTALLATIONS). 4. INSULATION CLASS - 220 DEG C, UL-COMPONENT-RECOGNIZED INSULATION SYSTEM WITH A MAXIMUM OF 150 DEG C RISE ABOVE 40 DEG C AMBIENT TEMPERATURE. 5. TAPS FOR TRANSFORMERS 25 KVA AND LARGER - TWO 2.5 PERCENT TAPS ABOVE AND FOUR 2.5 PERCENT TAPS BELOW NORMAL FULL CAPACITY. 6. WALL BRACKETS - MANUFACTURER'S STANDARD BRACKETS. 7. LOW-SOUND-LEVEL-REQUIREMENTS - MINIMUM OF 3 DBA LESS THAN NEMA ST 20 STANDARD SOUND LEVELS WHEN FACTORY TESTED ACCORDING TO IEEE C57.12.91. P.GUARANTEE 1. GUARANTEE MATERIAL FURNISHED AND WORKMANSHIP PERFORMED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF WORK. ANY DEFECTS DEVELOPING WITHIN THIS PERIOD, TRACEABLE TO MATERIAL FURNISHED AS A PART OF THIS SECTION OR WORKMANSHIP PERFORMED HEREUNDER, SHALL BE MADE GOOD AT NO EXPENSE TO THE OWNER. T.SHOP DRAWINGS AND APPROVALS 1. THE ITEMS SPECIFIED HEREIN AND ON DRAWINGS ARE USED AS A STANDARD OF QUALITY. ANY MATERIALS OF EQUAL QUALITY AND AESTHETIC VALUE WILL BE GIVEN CONSIDERATION AS A SUBSTITUTE FOR THE MATERIALS SPECIFIED. NO APPROVAL WILL BE GIVEN TO A SPECIFIC CATALOG NUMBER, MODEL, OR TYPE OF EQUIPMENT, PRIOR TO BIDDING. AFTER BIDDING, THE DECISION OF THE ARCHITECT AND/OR ENGINEER DETERMINING EQUAL MATERIALS WILL BE FINAL. 2. THE CONTRACTOR SHALL SUBMIT SEVEN (7) IDENTICAL BOUND SETS OF SHOP DRAWINGS ON THE FOLLOWING ITEMS: a. LIGHTING FIXTURE CUTS AND PERFORMANCE DATA. b. OUTLINE DRAWINGS AND DATA SHEETS OF EACH PANELBOARD AND SWITCHBOARD. c. OUTLINE DRAWINGS OF ALL SWITCHGEAR. 3. SUBMIT ITEMS AT ONE TIME IN A NEAT AND ORDERLY MANNER WITHIN 15 DAYS OF AWARD OF CONTRACT. PARTIAL SUBMITTALS WILL NOT BE ACCEPTABLE. U.RECORD AND AS-BUILT DRAWINGS 1. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN A SET OF DRAWINGS AT THE JOB SITE FOR THE EXCLUSIVE PURPOSE OF MAINTAINING A RECORD OF WORK INSTALLED AND TO SHOW ANY DEVIATIONS FROM THE WORK INDICATED ON THE DRAWINGS. 2. AT THE COMPLETION OF THE PROJECT, ONE SET OF REPRODUCIBLE DRAWINGS, SHOWING AS-BUILT CONDITIONS, SHALL BE DELIVERED TO THE OWNER FOR ACCEPTANCE PRIOR TO FINAL PAYMENT. V.COORDINATION STUDY & ARC FLASH REQUIREMENTS 1. THE ELECTRICAL CONTRACTOR MUST HIRE AN INDEPENDANT THIRD PARTY TO PERFORM A COORDINATION STUDY OF THE ENTIRE ELECTRICAL SYSTEM. THE COORDINATION STUDY SHALL BE PERFORMED AFTER THE ENGINEER HAS APPROVED THE SHOP DRAWINGS AND A MANUFACTURE HAS BEEN SELECTED. THE STUDY MUST BE PRESENTED TO THE ENGINEER AND OWNER FOR REVIEW TO ENSURE THE ENTIRE ELECTRICAL SYSTEM IS PROPERLY COORDINATED. 2. ARC FLASH REQUIREMENTS: a. PROVIDE AN ARC FLASH EVALUATION FOR THE NEW ELECTRICAL EQUIPMENT. PERFORM ALL CALCULATIONS AND WORK WITH COMMERCIALLY AVAILIBLE COMPUTER SOFTWARE IN ACCORDANCE WITH IEEE STD. 1584-2002 IEEE GUIDE FOR PERFORMING ARC-FLASH HAZARD CALCULATIONS, NFPA 70-2009 (NEC), AND NFPA 70E-2009 STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE. b. WHERE THE CALCULATIONS DETERMINE THAT THE SETTINGS RESULT IN PROHIBITIVE INCIDENT ENERGY LEVELS (>40 CAL/CM2) THE CONTRACTOR SHALL PROVIDE RECOMMENDED SETTINGS OR OTHER MITIGATION RECOMMENDATIONS TO REDUCE THE INCIDENT ENERGY TO A LEVEL WHERE ENERGIZED WORK IS CAPABLE OF BEING PERFORMED. THE CONTRACTOR SHALL DOCUMENT THE RECOMMENDED CHANGES AND PROVIDED TIME CURRENT CURVES INDICATING THE COORDINATION THAT REFLECTS THE RECOMMENDED SETTINGS. c. PROVIDE LABELS FOR EACH ELECTRICAL ENCLOSURE OR EQUIPMENT WHERE WORKERS COULD BE EXPOSED TO ENERGIZED CONDUCTORS. THESE LABELS SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70E-2009 AND INCLUDE BUT NOT LIMITED TO: 1. VOLTAGE PHASE TO PHASE 2. FLASH PROTECTION BOUNDARY (INCHES) 3. INCIDENT ENERGY AT THE WORKING DISTANCE(CAL/CM2) 4. PPE CLASS AND DESCRIPTION (INCLUDING GLOVE RATING) 5. RESTRICTED APPROACH BOUNDARY (INCHES) 6. LIMITED SHOCK PPROACH BOUNDARY (INCHES) 7. PROHIBITED SHOCK APPROACH BOUNDARY (INCHES) 8. LOCATION IDENTIFICATION ELECTRICAL SPECIFICATIONS E-002 ELECTRICAL SPECIFICATIONS & SITE PLAN AL BK SC 11"= 1/16'OVERALL SITE PLAN-ELECTRICAL TRUE NORTH N PROJECT LOCATION EL C A M I N O R E A L O R I O N R O A D 1 E-100 PWM26-3895FAC Exhibit "B" (Cont.) Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B -0 u 0 " L -u u w N 0 0 I w co 0 0 X N N / u u w "' 0 / 0 <Cc u "' 0 / n 0 0 z "' 0 u f--- V) 7 0 c= s,: f---V) u z (j rY s,: I () > w f- () 0: f--- V) 0 [l' w f- ~ ' s,: Q_ u z 7 ::, 0 sf rn V) _J er <l () "' 0 0 X N ;: TI u L u ~ V) / N N 0 N / U) f-u w 7 0 [l' Q_ / vi N 0 "' N 0 N oci N >, L 0 a L _o u ,, N 0 0 I ,,, -W 7 0 >, 0 _J -0 u i)j~~~~---ID li dlfflilil111111lllllllli if L u c u L " _o 0 m :-;, ll) u 0 -,, 0 ii: ~IA.L 3EFORE I vc,u DIG \ITWO WO,KIIJG JAYS BEFORE / YOU CIG -------- -- DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION 8 --___ ., DATE INITIAL OTHER APPROVAL I I I I I DATE INITIAL CITY APPROVAL P.E. __ _ EXP. ___ _ DEPUTY CITY ENGINEER P.E. C61909 -EXPIRES 09 30 25 DWN BY: PROJECT NO. DRAWING NO. CHKD BY: RVWD BY: # E-003 JS BK SC SINGLE LINE DIAGRAM "AS BUILT" DATE INSPECTOR DATE CMWD - ELECTRIC VEHICLE CHARGING STATIONS REVIEWED BY: IM P R O V E M E N T P L A N S - C I T Y O F C A R L S B A D - F I R E S T A T I O N N O . 1 S W I T C H B O A R D R E P L A C E M E N T FO LCA I R SI EG NE C No. E22808 LTA S E TE ITREC E S ETR V TE INAAL F O R I G N E R N EE RDP FO E SSIO L NA N LCO IL S M. Exp. 06-30-25 DATE SIGNEDDATE SIGNED 06/05/24 60% DESIGN PHASE01/15/25 BNK 1 PETERS CANYON ROAD, SUITE 130 IRVINE, CA. 92606 TEL: 949-387-8500, FAX: 949-387-0800 IDS IDS GROUP Project # 22X005.06 5950 EL CAMINO, CARLSBAD, CA 92008 90% DESIGN PHASE02/14/25 BNK 100% CD-ISSUE TO PLAN CHECK02/27/25 BNK UG P S M (E) MAIN SWITCHBOARD 'MSB' 1000A, 108/120V, 3Ø, 4W, 50kAIC RATED (MIN) NEMA 1 ENCLOSURE N G BOND (E) COLD WATER PIPE PANEL EV (E) 100A 3P (E) (N) 1000A BUS SDGE SECTION SDGE (E)1#2/0 THWN IN 3/4"C TO (E) GND ROD SINGLE LINE DIAGRAM NOTES 1. OVER-CURRENT DEVICES IN AN INDIVIDUAL PIECE OF EQUIPMENT SHALL HAVE AN A.I.C RATING EQUAL TO THE OVERALL RATING OF THE EQUIPMENT. SERIES RATING IS PROHIBITED. 2. TERMINATIONS AND ENCLOSURES SHALL BE RATED FOR USE WITH 75 DEGREE CELSIUS CONDUCTORS. 3. MAIN, FEEDER OR BRANCH CIRCUIT BREAKERS SHALL BE 100% RATED. 4. BUSSING: a. BUSSING SHALL BE TINNED COPPER CLAD CONSTRUCTION. HORIZONTAL AND VERTICAL BUSSING SHALL BE FULL CAPACITY IN SWITCHBOARD SECTIONS. b. HORIZONTAL AND VERTICAL BUSSING SHALL BE FULL LENGTH. BUSSING SHALL HAVE A MINIMUM WITHSTAND RATING EQUAL TO THE AVAILABLE FAULT CURRENT INDICATED, BUT IN NO CASE SHALL THE RATING BE LESS THAN 65,000 AMPS, SYMMETRICAL. 7. UNDERGROUND AND ABOVE GROUND CONDUCTORS IN EXPOSED CONDUIT SHALL BE THWN-2, TEMPERATURE RATING OF 90 DEGREES. 8. CONTRACTOR SHALL PROVIDE A PROJECT MEANS AND METHODS FOR MAINTAINING SYSTEM OPERATION AND SYSTEM CONTROLS TO MINIMIZE ALL ELECTRICAL OUTAGES. 9. COMPLY WITH 2022 CALIFORNIA ELECTRICAL CODE, ARTICLE 625. SUSTAINABLE OPERATION 1. CONTRACTOR SHALL PREPARE A SEQUENCE OF CONSTRUCTION EVENTS TO MAINTAIN THE EXISTING WATER DISTRICT OPERATIONAL WHILE WORKING ON THE MAIN SWITCHBOARD DURING THE RENOVATION AND INSTALLATION OF NEW ELECTRICAL EQUIPMENT. COORDINATE ALL SHUTDOWNS WITH THE CITY PROJECT MANAGER AND WATER DISTRICT PERSONNEL. PANEL DP (E) (E) 800AS 800AF 3P F (E) 200AS 175AF 2P (E) T-1 25KVA (Z=5.7%) 208V-240/120V,3Ø,3W (E)(1)#6CU TO GRD ELECTRODE F PANEL B (E) (E) 200AS 125AF 2P (E) 60AS 60AF 2P (E) 60AS 60AF 2P TO (E) PARKING LOT LIGHTS (E) 100A 3P SPARE (E) 30AS 20AF 1P FF (E) SDGE PAD MTD XRMR #D117371-586 T (E) LOADS EV KEY NOTES DISCONNECT AND REMOVE EXISTING CIRCUIT BREAKER AND PROVIDE A NEW CIRCUIT BREAKER TO BE 100% RATED AND MATCH EXISTING PANEL CHARACTERISTICS AND A.I.C. RATING. CIRCUIT BREAKERS SHALL BE GROUND FAULT PROTECTION TYPE, CEC 625.54. 1 1 A-SINGLE LINE DIAGRAM FIN. ASPHALT TO (E) FIRE SYSTEM (E)INCOMING FROM SDGE 30KAIC RATED 2 2 2 2 PWM26-3895FAC Exhibit "B" (Cont.) Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B (E) LANDSCAPE A E-100 (E) BUILDING (E) SECURED YARD GATE (E) ELEC. ROOM 1 2 3 4 5 6 7 8 9 10 11 12 13 EV PB PB PB EV (E) CHAIN LINK FENCE (E) 14" H. CMU WALL EV PB (FUT) EVCS 'EV3'(N) EVCS 'EV2' (N) EVCS 'EV1' EV1 EV3 EV2 EV31 EV1 EV3 EV2 1 1 EV1 EV2 EV3 B E-100 C E-100 TYP TYP (PVC) (E) LANDSCAPE T (E) SDGE XFMR (E) BUILDING (E) ASPHALT FLEET PARKING (E) ASPHALT PARKING 34 E E-100 EV4 EV5 EV3 EV3 EV4 EV5 T F F X X X PB EV1 EV2 EV3 EV1 EV2 EV3 (E) SWITCHBOARD 'MSB' EV (N) PANEL 'EV' (E) S (E) (E) A E-003 D E-100 (E)ASPHALT (E)LANDSCAPE SURFACE MTD. ON GYP. CEILING WITH UNISTUT SUPPORT/CLAMPS EV4 EV5 24"Ø x 24"D CONCRETE BASE CONC. SHALL BE 6" AFG EV CHARGING STATION CONCRETE EXPANSION ANCHOR BOLTS PER MANUFACTURERS INSTALLATION GUIDELINES (E)ASPHALT PAINT STRIPE PLAN VIEW NOTE: CONTRACTOR SHALL CONSTRUCT FROM ELECTRICAL MANUFACTURERS MAKE READY SHOP DRAWINGS AND SHALL BE CERTIFIED BY THE EV CHARGING STATION MANUFACTURER FOR EXACT LOCATIONS AND CONDUIT ROUGH-INS. UNDERGROUND CONDUIT PER SINGLE LINE DIAGRAM 10 " D E-100 (E) ASPHALT PARKING AREA (E) LANDSCAPE AREA x x x (E)CHAIN LINK FENCE (N)SS PULL BOX & EMT CONDUIT ANCHORED ON P1000 UNISTRUT WITH EPOXY EMBEDDED FASTERNERS, HILTI OR EQUAL (E)14"H. CMU WALL "AS BUILT" DATE INSPECTOR DATE CMWD - ELECTRIC VEHICLE CHARGING STATIONS REVIEWED BY: IM P R O V E M E N T P L A N S - C I T Y O F C A R L S B A D - F I R E S T A T I O N N O . 1 S W I T C H B O A R D R E P L A C E M E N T 60% DESIGN PHASE01/15/25 BNK 1 PETERS CANYON ROAD, SUITE 130 IRVINE, CA. 92606 TEL: 949-387-8500, FAX: 949-387-0800 IDS IDS GROUP Project # 22X005.06 5950 EL CAMINO, CARLSBAD, CA 92008 90% DESIGN PHASE02/14/25 BNK 100% CD-ISSUE TO PLAN CHECK02/27/25 BNK E-100 ELECTRICAL SITE PLAN AND DETAILS AL BK SC GENERAL NOTES 1. CONTRACTOR SHALL SUSTAIN AND MAINTAIN WATER DISTRICT OPERATIONS DURING CONSTRUCTION. COORDINATE ALL POWER OUTAGES WITH PROJECT MANAGER FOURTEEN DAYS PRIOR TO ANY SCHEDULE SHUTDOWN. 2. EXISTING LANDSCAPE IRRIGATION SYSTEM SHALL BE SHUTOFF DURING CONSTRUCTION AND INSTALLATION OF THE ELECTRIC VEHICLE CHARGER STATIONS. PROTECTED IN PLACE, AND THE CONTRACTOR WILL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING IRRIGATION SYSTEM AND REPAIR IF DAMAGED. 3. CONTRACTOR SHALL FIELD MARK ALL EVCS LOCATIONS AND CONFIRM WITH PROJECT MANAGER PRIOR TO ANY CONSTRUCTION EFFORT. 4. CONTRACTOR SHALL COORDINATE WITH PUBLIC WORKS SUPERINTENDENT BRADLEY NORTHUP, bradley.northup@calrsbadca.gov (442)339-5193 FOR EVCS PROGRAMMING AND SETUP REQUIREMENTS. 5. CONTRACTOR SHALL BE REQUIRED SCHEDULE ANY POWER OUTAGES TO PERFORM WORK ON THE EXISTING METERED SWITCHBOARD AND SHALL BE REQUIRED TO PROVIDE PROPER PERSONAL PROTECTION EQUIPMENT (PPE) BASED ON ELECTRICAL SYSTEM ARC FLASH LABELING. IF NO LABELING IS PROVIDE, CONTRACTOR SHALL ACCOMMODATE THE WORST CAST CONDITION. 11/16"=1'-0"PARTIAL SITE PLAN-ELECTRICAL TRUE NORTHN B1/4"=1'-0"CONCRETE BASE DETAIL CNO SCALETYPICAL TRENCHING DETAIL MINIMUM COVER REQUIREMENTS 0-600 VOLTS, NEC TABLE 300.5 (PARTIAL) DIRECT BURIAL CABLES OR CONDUCTORS (IN INCHES) OR CIRCUIT LOCATION OF WIRING METHOD NONMETALLIC RACEWAYS LISTED FOR DIRECT BURIAL WITHOUT CONCRETE ENCASEMENT OR OTHER APPROVED RACEWAYS 12 18 18 30 EQUIVALENT ALL LOCATIONS NOT SPECIFIED IN NEC TABLE 300.5 IN TRENCH BELOW 2" THICK CONCRETE OR 2424UNDER STREETS, HIGHWAYS ROADS, ALLEYS, DRIVEWAYS, AND PARKING LOTS UNDER A BUILDING 0 0 CLEAN SAND FINISHED GRADE MIN.COVER REQUIREMENTS. SEE TABLE 12" BACK FILL & COMPACTED WITH CLEAN SOIL WITHOUT DERIS. EVCS CONDUIT (LANDSCAPE AREA) PROVIDE CONDUIT SPACERS REFER TO SINGLE LINE DIAGRAM , SHEET E-3.00 FOR REQUIREMENTS 3"1.5x LARGEST CONDUIT (TYP) 1.5x LARGEST CONDUIT (TYP) +/-12" LANDSCAPE TRENCH A1/4"=1'-0"ELECTRICAL ROOM FLOOR PLAN DNO SCALECONCRETE BASE DETAIL KEY NOTES 1 12"Wx10"Lx6"D STAINLESS STEEL SCREW COVER GASKETED, NEMA 3R PULL BOX SECURED AND ANCHORED TO EXISTING CMU WALL WITH P1000 UNISTRUT SUPPORTS. HAMMOND OR EQUAL. PROVIDE AND INSTALL SURFACE MOUNTED RGS CONDUIT ON EXISTING CMU WALL AND SUPPORTED AT 10'-0" ON UNISTRUT. MOUNT PULL BOX 24"AFG TO BOTTOM OF BOX ON UNISTRUT SUPPORT. ROUTE CONDUIT ON BUILDING WITH UNISTRUT SUPPORTS AND CONDUIT CLAMPS. CORE EXISTING BUILDING FOR CONDUIT PENETRATION. PROVIDE 2 HOUR FIRE SEAL AT WALL. SECURELY MOUNT TO CEILING FASTENED P1000 UNISTRUT AND ASSOCIATED CONDUIT CLAMPS AT 10'-0" O.C. FIELD VERIFY EXISTING CONDITIONS AND AVOID EXISTING LIGHT FIXTURE. 2 3 4 1 E1"=1'-0"WALL DETAILS ELEVATION SIDE VIEW (E) CMU WALL D E-100 (N) EVCS (N) PULL BOX WITH P1000 UNISTRUCT SUPPORT ANCHORED TO (E) CMU WALL (E) FIN. GRADE (N) PULL BOX WITH P1000 UNISTRUCT SUPPORT ANCHORED TO (E) CMU WALL (E) CMU WALL PB (N) PVC CONDUITS (N) RGS CONDUITS SUPPORTDED P1000 UNISTRUT WITH CONDUIT CLAMPS (E) FIN. LANDSCAPE (N) EVCS 24"ØX24"D CONC. FOUNDATION WITH EPOXY ANCHORS PER MANUF. REQ. (N) PVC CONDUIT, SEE FEEDER SCHEDULE (E) FIN. ASPHALT SITE LOCATION (E) CMU WALL 10" RED MARKER TAPE LABELED 'ELECTRIC' 5 5 PWM26-3895FAC Exhibit "B" (Cont.) Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B EXHIBIT C LABOR AND MATERIALS BOND PWM26-3895FAC Bond# GRCA70847 WHEREAS, the Board of Directors of the Carlsbad Municipal Water District has awarded to Saturn Electric, Inc. (hereinafter designated as the "Principal"), a Contract for: CARLSBAD MUNICIPAL WATER DISTRICT EV CHARGING STATIONS CONTRACT NO. 5063 in the City of Carlsbad, in strict conformity with the drawings and specifications, and other Contract Documents now on file in the Office of the City Clerk of the City of Carlsbad and all of which are incorporated herein by this reference. WHEREAS, Principal has executed or is about to execute said Contract and the terms thereof require the furnishing of a bond, providing that if Principal or any of its subcontractors shall fail to pay for any materials, provisions, provender or other supplies or teams used in, upon or about the performance of the work agreed to be done, or for any work or labor done thereon of any kind, the Surety on this bond will pay the same to the extent hereinafter set forth. NOW, THEREFORE, WE, Saturn Electric, Inc., as Principal, (hereinafter designated as the "Contractor"), and Granite Re, Inc. dba Granite Surety Insurance Company as Surety, are held firmly bound unto CMWD in the sum of thirty-six thousand seven hundred fifty-four dollars ($36,754), said sum being an amount equal to: One hundred percent (100%) of the total amount payable under the terms of the Contract by the City of Carlsbad, and for which payment well and truly to be made we bind ourselves, our heirs, executors and administrators, successors, or assigns, jointly and severally, firmly by these presents. THE CONDITION OF THIS OBLIGATION IS SUCH that if the Contractor or his/her subcontractors fail to pay for any materials, provisions, provender, supplies, or teams used in, upon, for, or about the performance of the work contracted to be done, or for any other work or labor thereon of any kind, consistent with California Civil Code section 9100, or for amounts due under the Unemployment Insurance Code with respect to the work or labor performed under this Contract, or for any amounts required to be deducted, withheld, and paid over to the Employment Development Department from the wages of employees of the contractor and subcontractors pursuant to section 13020 of the Unemployment Insurance Code with respect to the work and labor, that the Surety will pay for the same, and, also, in case suit is brought upon the bond, reasonable attorney's fees, to be fixed by the court consistent with California Civil Code section 9554. This bond shall inure to the benefit of any of the persons named in California Civil Code section 9100, so as to give a right of action to those persons or their assigns in any suit brought upon the bond. Surety stipulates and agrees that no change, extension of time, alteration or addition to the terms of the Contract, or to the work to be performed hereunder or the specifications accompanying the same shall affect its obligations on this bond, and it does hereby waive notice of any change, extension of time, alterations or addition to the terms of the contract or to the work or to the specifications. In the event that Contractor is an individual, it is agreed that the death of any such Contractor shall not exonerate the Surety from its obligations under this bond. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 14 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-3895FAC This labor and materials bond may be approved as to form by the General Counsel for CMWD in counterpart, and the counterparts shall all constitute a single, original instrument. SIGNED AND SEALED, this 'l.-1)fZO day of ___ �..1�\)�\.:-'+1-----�· 2025. Granite Re, Inc. dba _Sa_t_u_r _n _E _le_c _tr_ic_,_ln_c_. ______ (SEAL) Granite Surety Insurance Company (SEAL) (Principal) (Surety) (Signature) , (Signature) Attorney-In-Fact (SEAL AND NOTARIAL ACKNOWLEDGEMENT OF SURETY-ATTACH ATTORNEY-IN-FACT CERTIFICATE) APPROVED AS TO FORM: CINDIE K. McMAHON General Counsel By: Assistant General Counsel Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 15 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B By: -~~-;2_~:::..t·t--:==:.._ _____ By: Kenneth :.Whittingto , ~~.L= Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of the document. ACKNOWLEDGMENT OF PRINCIPAL State of CA l-\ fo~ \1\ County of '5P5,N 'O\E.l;:,D On this 'l"'of,D day of .j\) Li , 20 '2S , before me AM~ ::O~ Ot-V-1 ~ ?J0U( personally appeared Here insert Name and Title of Officer __ :1\~M~Q:fltf~'-'-+~"~Ll&~~N~\)~\)~~~~~---' who proved to me on the basis of satisfactory evidence to be the person Name of Signer whose name is subscribed to the within instrument and acknowledged to me that he/she executed the same in his/her authorized capacity, and that by his/her signature on the instrument the person, or the entity upon behalf of which the person acted, executed the instrument. I certify under the PENAL TY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. AMY DUDEK COMM. #2521061 z Notary Public • Callfornla· ~ San Diego County ~ v~r..:x""' My Comm. Expires June 19, 2029 WITNESS my h ACKNOWLEDGMENT OF SURETY State of Oklahoma County of Oklahoma On this 16 day of July, 2025 before me personally come(s) Kenneth D. Whittington, Attorney-in-Fact of Granite Re , Inc. DBA Granite Surety Insurance Company with whom I am personally acquainted, and who, being by me duly sworn, says that he reside(s) in Oklahoma City, Oklahoma that he is the Attorney-in-Fact of Granite Re, Inc. DBA Granite Surety Insurance Company, the company described in and which executed the within instrument; that he know(s) the corporate seal of such Company; and that the seal affixed to the within instrument is such corporate seal and that it was affixed by order of the Board of Directors of said company, and he signed said instrument as Attorney(s)-in-Fact of the said Company by like order. GR-34 (CA) Ed. 01-22 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY GENERAL POWER OF ATTORNEY Know all Men by these Presents: That GRANITE RE, INC. DBA GRANITE SURETY INSURANCE COMPANY, a corporation organized and existing under the laws of the State of MINNESOTA and having its principal office at the City of OKLAHOMA CITY in the State of OKLAHOMA does hereby constitute and appoint: KENNETH D. WHITTINGTON; KYLE MCDONALD its true and lawful Attorney-in-Fact{s) for the following purposes, to wit: To sign its name as surety to, and to execute, seal and acknowledge any and all bonds, and to respectively do and perform any and all acts and things set forth in the resolution of the Board of Directors of the said GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY a certified copy of which is hereto annexed and made a part of this Power of Attorney; and the said GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY through us, its Board of Directors, hereby ratifies and confirms all and whatsoever the said: KENNETH D. WHITTINGTON; KYLE MCDONALD may lawfully do in the premises by virtue of these presents. In Witness Whereof, the said GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY has caused this instrument to be sealed with its corporate seal, duly attested by the signatures of its President and Assistant Secretary, this 31st day of July, 2023. ST ATE OF OKLAHOMA COUNTY OF OKLAHOMA SS: Kenneth D. Whitti ton, President / JI i ;-r/l _rj,/l,,./ Kyle'P. McDonald, Assistant Secretary On this 31st day of July, 2023, before me personally came Kenneth D. Whittington, President of the GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY and Kyle P. McDonald, Assistant Secretary of said Company, with both of whom I am personally acquainted, who being by me severally duly sworn, said, that they, the said Kenneth D. Whittington and Kyle P. McDonald were respectively the President and the Assistant Secretary of GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY, the corporation described in and which executed the foregoing Power of Attorney; that they each knew the seal of said corporation; that the seal affixed to said Power of Attorney was such corporate seal, that it was so fixed by order of the Board of Directors of said corporation, and that they signed their name thereto by like order as President and Assistant Secretary, respectively, of the Company. My Commission Expires: April 21, 2027 Commission#: 11003620 GRANITE RE, INC. Certificate THE UNDERSIGNED, being the duly elected and acting Assistant Secretary of GRANITE RE, INC. DBA GRANITE SURETY INSURANCE COMPANY, a Minnesota Corporation, HEREBY CERTIFIES that the following resolution is a true and correct excerpt from the July 15, 1987, minutes of the meeting of the Board of Directors of GRANITE RE, INC. OBA GRANITE SURETY INSURANCE COMPANY and that said Power of Attorney has not been revoked and is now in full force and effect. "RESOLVED, that the President, any Vice President, the Assistant Secretary, and any Assistant Vice President shall each have authority to appoint individuals as attorneys-in-fact or under other appropriate titles with authority to execute on behalf of the company fidelity and surety bonds and other documents of similar character issued by the Company in the course of its business. On any instrument making or evidencing such appointment, the signatures may be affixed by facsimile. On any instrument conferring such authority or on any bond or undertaking of the Company, the seal, or a facsimile thereof, may be impressed or affixed or in any other manner reproduced; provided, however, that the seal shall not be necessary to the validity of any such instrument or undertaking." IN WITNESS WHEREOF, the undersigned has subscribed this Certificate and affixed the corporate seal of the Corporation this , 2025. Kyle I( McDonald, Assistant Secretary GR-40 (CA) Ed. 06-24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B To be attached to bond number GRCA70847 Bond Number: GRCA70847 Principal: Saturn Electric, Inc. Obligee: Carlsbad Municipal Water District Premium: $265.00 GR-48 (CA) Ed. 06-24 PWM26-3895FAC EXHIBIT D IN-USE OFF-ROAD DIESEL-FUELED FLEET REGULATION REQUIREMENTS CARB implemented amendments to the In-Use Off-Road Diesel Fueled Fleets Regulations that apply broadly to all self-propelled off-road diesel vehicles 25 horsepower or greater and other forms of equipment used in California. More information about the requirements can be found at https://ww2.arb.ca.gov/our-work/programs/use-road-diesel-fueled-fleets-regulation Contractors are required to comply with the requirements of the In-Use Off-Road Diesel-Fueled Fleet regulations, including, without limitation, compliance with Title of the California Code of Regulations section 2449 et seq. throughout the term of the Project. CMWD is a "Public Works Awarding Body," as that term is defined under Title 13 California Code of Regulations Section 2449(c)(46). Accordingly, the Contractor must submit, with their pre-award contract documents, valid Certificates of Reported Compliance (CRC) for the Contractor's fleet, and for the fleets of any listed subcontractors (including any applicable leased equipment or vehicles). Failure to provide a valid CRC, will limit CMWD's ability to proceed with awarding this Contract. Contractor has an on-going obligation for term of this Contract to provide copies of Contractor's, as well as all listed subcontractors, most recent CRC issued by CARB. Throughout the Project, and for three (3) years thereafter, Contractor shall make available for inspection and copying any and all documents or information associated with Contractor's and subcontractors' fleet including, without limitation, CRC, fuel/refueling records, maintenance records, emissions records, and any other information the Contractor is required to produce, keep or maintain pursuant to the Regulation upon two (2) calendar days' notice from CMWD. Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 16 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PWM26-3895FAC EXHIBIT D (CONT.) IN-USE OFF-ROAD DIESEL-FUELED FLEET REGULATION CERTIFICATION Contractor hereby acknowledges that they have reviewed the CAR B's policies, rules and regulations and are familiar with the requirements of In-Use Off-Road Diesel-Fueled Fleet Regulation. Contractor hereby certifies, subject to the penalty of perjury, that the option checked below relating to the Contractor's fleet, and/or that of their subcontractor(s) ("Fleet") is true and correct: □The Fleet is subject to the requirements of the Regulation, and the appropriate Certificate(s) of Reported Compliance have been attached hereto. □The Fleet is exempt from the Regulation under Section 2449.l(f)(2), and a signed description of the subject vehicles, and reasoning for exemption has been attached hereto. □Contractor and/or their subcontractor is unable to procure R99 or RlOO renewable diesel fuel as defined in the Regulation pursuant to Section 2449.l(f)(3). Contractor shall keep detailed records describing the normal refueling methods, their attempts to procure renewable diesel fuel and proof that shows they were not able to procure renewable diesel (i.e., third party correspondence or vendor bids). □The Fleet is exempt from the requirements of the Regulation pursuant to Section 2449(i)(4) because this Project has been deemed an "emergency", as that term is defined in Section 2449(c)(18). Contractor shall only operate the exempted vehicles in the emergency situation and records of the exempted vehicles must be maintained, pursuant to Section 2449(i)(4). The Fleet does not fall under the Regulation or are otherwise exempt and a detailed reasoning is attached to this certification. Name of Contractor: =Sa=-t=u"-r'-'-n-=E=le=c=tr'""'ic=--"I n""c"'". ___________ _ Signature: g ,e, Name: Timothy Allen Dudek Title: President Carlsbad Municipal Water District EV Charging Stations Cont. No. 5063 Page 17 General Counsel Approved 6/5/24 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B,,,,,.----, I ACORD® CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) ~ 12/28/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME7~ CLIENT CONTACT CENTER FEDERATED MUTUAL INSURANCE COMPANY PHONE I FAX HOME OFFICE: P.O. BOX 328 (A/C, No, Ext): 888-333-4949 (A/C, No): 507-446-4664 OWATONNA, MN 55060 E-MAIL ADDRESS: CLI ENTCONTACTCENTER@ FEDI NS.COM INSURERS AFFORDING COVERAGE NAIC # INSURER A:FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED INSURER B: SATURN ELECTRIC, INC. INSURER C: 7552 TRADE ST SAN DIEGO, CA 92121-2412 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 105 REVISION NUMBER: 0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER ,J~MgM/..fy1 ,;~h~'E,')'yWy1 LIMITS LTR INSR WVD COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 -:=J CLAIMS-MADE 0 OCCUR DAMAGE TO RENTED PREMISES (Ea occurrence) $100,000 -X BUSINESS OWNER'S LIABILITY MED EXP (Any one person) A -y N 1873527 10/01/2024 10/01/2025 PERSONAL & ADV INJURY $1 ,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2 000 000 ~ POLICY Ori-.: □Loe PRODUCTS & COMP/OP ACC $2,000,000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 ,000,000 (Ea acciden~ - X ANY AUTO BODILY INJURY (Per Person) --A OWNED AUTOS ONLY SCHEDULED N N 1873528 10/01/2024 10/01/2025 BODILY INJURY (Per Accident) AUTOS -- iP~~~~~i~~n?iAMAGE HIRED AUTOS ONLY NON-OWNED AUTOS ON LY -- X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $2,000,000 -- A EXCESS LIAB CLAIMS-MADE N N 1873531 10/01/2024 10/01/2025 AGGREGATE $2,000,000 DED I I RETENTION WORKERS COMPENSATION I PER STATUTE I pTHER AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/ EXECUTIVE C E.L EACH ACCIDENT OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L DISEASE -EA EMPLOYEE If yes, describe under DESCRIPTION OF OPERATIONS below E.L DISEASE • POLICY LIMIT DESCRIPTION OF OPERATIONS/ LOCATIONS/ VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) SEE ATTACHED PAGE CERTIFICATE HOLDER CANCELLATION CITY OF CARLSBAD/CMWD 105 0 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED C/O EXIGIS INSURANCE COMPLIANCE SERVICES PO BOX 947 BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN MURRIETA, CA 92564-0947 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ;JJ.t e~ © 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B AGENCY CUSTOMER ID: ----------------------LO C #: ---------------------- .• ~® ACORD ~, ADD IT 10 NA L REMARKS SCHEDULE Page of AGENCY NAMED INSURED FEDERATED MUTUAL INSURANCE COMPANY SATURN ELECTRIC, INC. 7552 TRADE ST POLICY NUMBER SAN DIEGO, CA 92121-2412 SEE CERTIFICATE# 105.0 CARRIER I NAIC CODE EFFECTIVE DATE: SEE CERTIFICATE# 105.0 SEE CERTIFICATE# 105.0 ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: -~2=5~_ FORM TITLE: CERTIFICATE OF LIABILITY INSURANCE THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR BUSINESSOWNERS LIABILITY. INSURANCE PROVIDED BY THE BUSINESSOWNERS LIABILITY IS PRIMARY AND NONCONTRIBUTORY OVER OTHER INSURANCE SUBJECT TO THE CONDITIONS OF THE PRIMARY AND NON-CONTRIBUTORY CLAUSE ENDORSEMENT FOR REASONS OTHER THAN NON-PAYMENT OF PREMIUM, 30 DAYS NOTICE WILL BE PROVIDED TO THE CERTIFICATE HOLDER IN THE EVENT THAT THE ISSUING COMPANY CANCELS THE POLICY BEFORE THE EXPIRATION DATE OF THE POLICY. ACORD 101 (2008/01) © 2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B FEDERATED INSURANCE COMPANIES THIS ENDORSEMENT MODIFIES THE POLICY. PLEASE READ IT CAREFULLY. ADDITIONAL INSURED BY CONTRACT ENDORSEMENT This endorsement modifies insurance provided under the following: BUSINESSOWNERS LIABILITY COVERAGE FORM A. Paragraph C. Who Is An Insured is amended to include as an additional insured any person or organization, other than a joint venture, for whom you are performing operations when you and such person or organization have agreed in writing in a contract or agreement that such person or organization be added as an additional insured on your policy Such person or organization is an additional insured only with respect to liability for "bodily injury", "property damage" or "personal and advertising injury" caused, in whole or in part, by: 1. Your acts or omissions; or 2. The acts or omissions of those acting on your behalf; in the performance of your ongoing operations for the additional insured A person's or organization's status as an additional insured under this endorsement ends when your operations for that additional insured are completed This additional insurance does not apply to: 1. An employee, association of employees or labor union, except with respect to work performed by or for you for such employee, association of employees or labor union under direct contract between you as contractor and such employee, association of employees or labor union as owners; 2. Any railroad company except with respect to work performed by or for you for such railroad company under direct contract or agreement between you and such railroad company; 3. Any person or organization whose profession, business or occupation is that of an architect, surveyor or engineer with respect to liability arising out of the preparation or approval of or the failure in preparation or approval of maps, shop drawings, opinions, reports, surveys, field orders, change orders, designs, drawings, specifications or the performance of any other professional services by such person or organization; or 4. Any of your Subcontractors, or any partner, officer, agent or employee of such Subcontractor B. The Coverage extended to any additional insured by this endorsement is limited to, and subject to, all terms, conditions, and exclusions of the coverage form to which this endorsement is attached In addition, Coverage shall not exceed the terms and conditions that are required by the terms of the written agreement to add any insured, or to procure insurance C. In the event that the Limits of Insurance shown in the Declarations exceeds the limits of liability required in a written contract or written agreement for an additional insured, the insurance provided to the additional insured shall be limited to the limits of liability required by that written contract or written agreement D. Additional Exclusions The insurance afforded to any person or organization as an insured under this endorsement does not apply: 1. To "bodily injury", "property damage" or "personal and advertising injury" which occurs prior to the date of your contract with such person or organization; 2. To "bodily injury" or "property damage" included within the "products completed operations hazard"; or 3. To "bodily injury", "property damage" or "personal and advertising injury" arising out of the sole negligence of any person or organization that would not be an insured except for this endorsement Includes copyrighted material of Insurance Services Office, Inc with its permission BP F 115 (07 09) Policy Number: 1873527 Transaction Effective Date: 10/01/2024 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. PRIMARY AND NON-CONTRIBUTORY CLAUSE ENDORSEMENT This endorsement modifies insurance provided under the following: BUSINESSOWNERS LIABILITY COVERAGE FORM It is agreed that the insurance provided by any additional insured endorsement is primary We will not seek contribution from any other insurer when insurance on a non contributing basis is required by contract Includes copyrighted material of Insurance Services Office, Inc with its permission BP F 119 (07 04) Policy Number: 1873527 Transaction Effective Date: 10/01/2024 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B-I DATE (MM/DD/YYYY) -Ill..-'L-'K LJ \..C" 111"'1\..A IC Ut' LIABILITY INSURANCE 12/09/2024 ~ THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER($), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In Heu of such endorsement(s). PRODUCER CONTACT NAME: Breckpoint PHONE (800} 592-0047 I FAX (800} 592-2541 (A/C, No, Ext): (A/C. No, Ext): Administrator, California Contractors Network, Inc. E-MAIL service@breckpoint.com ADDRESS: 430 N Vineyard Ave .. #102 INSURER($) AFFORDING COVERAGE NAIC# Ontario, CA 91764 INSURER A: California Contractors Network, Inc.• INSURED INSURER&: Safety National Casualty Corporation 15105 Saturn Electric, Inc. INSURERC: Affiliate of california Contractors Network, Inc. INSURERD: 7552 Trade St. INSUR9!: San Diego, CA 92121 INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS ISTOCERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUEDTO THE INSURED NAMEDABOVE FORTHE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY EQUIREMENT, TERM, OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR PDLICYEFF POUCYEXP LTR TYPE OF INSURANCE INSR WVD POUCY NUMBER IMulpp/Vvvv\ IMMIDD""""" LIMITS COMMERCIAL GENERAL UABILITY EACH OCCURRENCE $ ~ □ CLAIMS-MADE □ OCCUR DAMAGE TO RENTED PREMISES (Ea occurrencel $ MED EXP (Any one person) $ ~ □ □ PERSONAL & ADV INJURY $ - ~ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY □ PROJECT □ LOC PRODUCTS -COMP/OP AGG $ OTHER $ COMBINED SINGLE LIMIT $ AUTOMOBILE LIABILITY (Ea accident) -ANY AUTO BODILY INJURY (Per person) $ --□ □ ANY OWNED SCHEDULED BODILY INJURY (Per accident) $ AUTOS AUTOS -- HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTO (Per accident) --$ UMBREUA UAB □ OCCUR EACH OCCURRENCE $ -□ □ EXCESS UAB CLAIMS-MADE AGGREGATE $ - DED n RETENTION $ $ WORKERS COMPENSATION XI WCSTATU- I I OTH- AND EMPLOYERS' UABILITY Y/N TORYUMITS ER A ANY PROPRIETOR/PARTNER/EXECUTIVE ~ N/A ~ 4503-098 01/01/202S 01/01/2026 E.L EACH ACCIDENT $5,000,000.00 OFFICE/MEMBER EXCLUDED? (Mandatory in NH) E.L DISEASE -EA EMPLOYEE $5,000,000.00 If yes, describe under E.L DISEASE -POLICY LIMIT $5,000,000.00 DESCRIPTION OF OPERATIONS below B EXCESS WORKERS COMPENSATION □ □ SP4067949 01/01/2025 01/01/2026 AND EMPLOYERS LIABILITY Applicable to WC Statutory Limits and Employers Liability Limits. DESCRIPTION OF OPERATIONS/ LOCATION/ VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space Is required) All California Operations •• Waiver of Subrogation applies-see attached•• •• See Notes** *Complies with the requirements of the Director of Industrial Relations under the provisions of Sections 3700 to 3705, inclusive, of the Labor Code of the State of California, holder of Master Certificate of Consent to Self-Insure No. 4503 CERTIFICATE HOLDER City of Carlsbad/CMWD c/o EXIGIS Insurance Compliance Services P.O. Box4668-ECM #35050 New York, NY 10163 ACORD 25 (2014/01) CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ,~~·· -f j_, A. Seegmiller ·.j C 1988-2010 ACORD CORPORATION. All rights reserved The ACCORD name and logo are registered marks of ACORD Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B PAGE2 NOTEPAD: INSURED'S NAME: Saturn Electric, Inc. DATE: 12/09/2024 City of Carlsbad Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B WORKERS COMPENSATION AND EMPLOYERS LIABILITY California Contractors Network, Inc. WAIVER OF OUR RIGHT TO RECOVER FROM OTHERS We have the right to recover our payments from anyone liable for a covered injury. We will not enforce our right against the person or organization named in the Schedule. (This agreement applies only to the extent that you perform work under a written contract that requires you to obtain this agreement from us.) This agreement shall not operate directly or indirectly to benefit anyone not named in the Schedule. Schedule Name of Person or Organization: City of Carlsbad/CMWD c/o EXIGIS Insurance Compliance Services P.O. Box 4668 -ECM #35050 New York NY 10163 City of Carlsbad Insured: Saturn Electric, Inc. Policy No.: 4503-098 Docusign Envelope ID: 359613DF-1AA6-47EF-AB90-105B5ED8CD9B 1.. CALIFORNIA ' DEPARTMENT OF INSURANCE