Loading...
HomeMy WebLinkAbout5860 OWENS AVE; ; FA010035; Permit7/24/25, 1:27 PM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: about:blank Fees($) 176 FA010035 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA010035 5860 OWENS AV Status: ISSUED FALARM Applied 8/21/2001 2120923300 Approved: 8/29/2001 0 Issued: 8/29/2001 Inspector: PALOMAR HEIGHTS PLAZA BLDG. 1 Add'I Fees ($) 0 Owner: BUIE CARLSBAD LOT 10 LL C 11260 EL CAMINO REAL #200 SAN DIEGO CA Total($) 176 Balance($) 0 1/1 Carlsbad Fire Departmerfill[ COPY 011243 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Alarm System Plan Reviewed by: Date of Report: _0_81_24_;2_0_0_1 _______ _ Name: JJJ Enterprises Address: 533 S. Vinewood City, State: Escondido CA 92029 Plan Checker: Job #: 011243 ------- Job Name: Palomar Heights #1 Bldg#: CB011243 ----------------~~ Job Address: 5860 Owens Avenue Ste. or Bldg. No. IZI Approved LJ Approved Subject to LJ Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 011243 2nd FD File# 3rd Other Agency ID FIRE ALARM • SECURITY • LOW VOLTAGE SYSTEMS PALOMAR HEIGHTS PLAZA BLDGS 1 &J:5 CARLSBAD, CA FIRE ALARM SYSTEM BILL OF MATERIALS C 3 PALOMAR HEIGHTS PLAZA BLDGS 1 & /,/ CARLSBAD, CA r FIRE ALARM SYSTEM BILL OF MATERIALS 1 NOTIFIER AFP-200 ADDRESSABLE CONTROL PANEL CSFM# 7165-0028:164 10 NOTIFIER FSP-751 INTELLIGENT SMOKE DETECTOR CSFM# 7272-1209:192 W/B710LPBP BASE CSFM# 7300-0028: 173 6 NOTIFIER FRM-1 RELAY MODUEL CSFM# 7300-0028:202 4 NOTIFIER FST-751 INTELLIGENT HEAT DETECTOR CSFM# 7270-0028:196 W/B710LPBP BASE CSFM# 7300-0028: 173 C C C ({;})NOTIFIER®. GENERAL The AFP-200 is a compact, cost-effective, intelligent fire alarm control with a capacity of 301 individually identified and controlled points and an extensive list of powerful fea- tures. The AFP-200 provides capabilities that exceed most large intelligent systems, at a cost comparable to conven- tional control panels. FEATURES 198 intelligent device capacity (99 analog detectors and 99 monitor/control modules). Style 4, 6, or 7. Overall 301 point capability (198 intelligent points, 4 pro- grammable NAG circuits, 99 programmable relays). Network ready (reference NOTI • FIRE• NET'" and NAM- 232 data sheets for more information). Intelligent features: v' Manual sensitivity adjustment. v' Day/Night automatic sensitivity adjustment. v' Drift compensation (U.S. Patent Pending) meets UL requirements as a calibrated test instrument. v' Auto detector test (meets NFPA 72). v' Maintenance alert (two separate algorithms). v Pre-alarm (AWACS™ U.S. Patent Pending). v Activate local sounder base on pre-alarm. v' LED blink control for sleeping areas. v' Automatic device type check. Releasing features: V Four independent hazards. v' Sophisticated cross-zone (three options) April 5, 2001 DN-3783 • A-105 AFP-200 Analog Fire Panel Section: Intelligent Fire Alarm Control Panels ® I California State Fire Marshal 7165-0028: 164 (not for releasing) LISTED CS118 S635 <8> FM U.S. Coast Guard 161.002/23/1 Approved ~ 94/60004 (E1) MEA 104-93-E Vol. VI (not for releasing) v' Delay timer and Discharge timers (adjustable). v' Abort (four options). TheAFP-200 Optional □ACT, with AC fail delay. LCD-80 remote display/control. ACS annunciators (EIA-485), including LDM custom. Printer interface (BO-column and 40-column printers). 5.0 A_ usable regulated output power, plus 6.0 A expander (maximum 8.0 A to panel circuits). SO-character LCD display, backlit. Real-time clock, with European format option. History file with 650-event capacity in nonvolatile memory. Includes non-erasable shadow history. Waterflow or supervisory selection per point. Alarm Verification selection per point, with tally. Walk Test reports two devices set to same address. Positive Alarm Sequence (PAS) Presignal per NFPA 72. Silence inhibit and Auto Silence timer options. March time/temporal/California code for bell circuits. Field-programmable on panel or on PC, with user-defined passwords, plus Autoprogram feature. UL Listed modem interface allows remote/off-site system integration. FZM-1 two-wire detector interface provides compatibility NOTl•FIRE•NET™ is a trademark of NOTIFIER, 1994. p2.wmf with many non-NOTI Fl ER detectors for retrofit applications (consult factory for latest compatibility listings). Dual-rate charger for up to 90 hours of standby power. Two-Stage option for notification circuits (Canada). Tornado Warning activates different notification circuit code. Non-alarm points for lower priority functions. Remote Silence/Reset/Evacuate via monitor modules. Automatic time control functions, with holiday exceptions. Rapid poll algorithm for manual stations. Responds in < 2 seconds. Operates with untwisted, unshielded wire (up to 1,000 ft./ 304.8 m) for retrofit applications (U.S. Patent 5,210,523). UL Listed for Fire Signaling per Standard 864 & NFPA 72. UL Listed for Burglary applications per Standard 1076. UL Listed for Releasing Service. Complies with NFPA 12, 12A, 12B, 13, 15, 16, 2001 Standards when installed in accordance with appropriate NFPA standard. UL Listed for Critical Process Monitoring. FM approved for Agent Release and Preaction/Deluge. MEA and CSFM approved; however, not approved for releasing by these agencies. Approved for marine applications by U.S. Coast Guard and Lloyd's Register of shipping. This do~ument i~ not intended to be used for installation purposes. We try to keep our pro~~ct 1nformabo~ up-to-date and accurate. We cannot cover all specific applications or antIc1pate all requirements. All specifications are subject to change without notice For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED @)NOTIFIER' 12 Clintonville Road, Northford, Connecticut 06472 INCINEIIINI: I MINllilfflllNI: Made in the U.S.A. DN-3783 • 04/05/01 -Page 1 of 4 SYSTEM BLOCK DIAGRAM NOTl•FIRE•NET'" Optional Network Interface via the NAM-232 FSl-751 FSP-751 Ion Photo EIA-485 FST-751 Thermal Fixed SLC Intelligent Loop DEVICES -----------------· NBG-12LX 99 software zones FMM-1 FCM-1 t i IDC IAC AFP-200 Four standard Notification or Releasing circuits. Full Alpha keyboard for menu-driven programming. 5 ampere regulated power supply. Voltmeter/ Ammeter Option. Page 2 of 4 -DN-3783 • 04/05/01 4 Notification or Release Circuits RS-232 PRN Series Printer EIA-232 interface for CRT, printer, or PC computer. ACM-BR Relay Control CRT-2 ACM/AEM-16AT LED Annunciator LDM-32 Custom Graphics EIA-485 loop for LCD or LED annunciators. SLC loop. Up to 198 devices on a single pair of wires. Slot for optional module. 3783dlag.wmf 12 AH batteries; 18 AH with BB-17. Up to 90 hours standby power. SO-character backlit LCD display. C AWACS™ Advance Warning Addressable Combustion Sensing (U.S. Patent Pending) SMOKE OBSCURATION % per foot 3% ALERT ACTION ALARM Warning at panel Shut off power Evacuate building of possible fire to equipment monitored and call fire department by this detector PREALM SMOKE(PHOTOI PREALM SMOKEIPHOTOI ALARM: SMOKEIPHOTOI FLOOR 3 EQUIP RACK 5 FLOOR 3 EQUIP RACK 5 FLOOR 3 EQUIP RACK 2% ALERT: 0.22% 1.40% ACTION: 0.51% 1.40% FIRE DEPT CALLED 11: 25 p 12/25/93 D66 11 :36 P 12125/93 066 11 :59 p 12/25/93 v v 1% i TIME~ ALERT and ACTION levels are completely adjustable in the field to suit the cleanliness and stability of the environment. ALARM levels are field adjustable to one of three levels within the UL permitted range. ACTION levels latch and may be used to perform control functions. ALERT levels self-restore and may be used to activate a local sounder base before general ALARM evacuation. FIELD PROGRAMMING -3WAYS 1. AUTO-PROGRAM The AFP-200 identifies all devices that are connect- ed, determines the type of device, and loads default values (general alarm) into nonvolatile memory. This is completed in less than 30 seconds. 2. ON-LINE EDIT While still providing fire protection, the AFP-200 pro- gram may be completely edited from the front keypad. Menu trees ermit eas chan e of an p y g y p arameter without referral to the programming manual. Recall, increment and edit function speeds entry of alphanu- meric labels. New program check routine catches common errors. 3. OFF-LINE PC: VeriFire-200 The complete AFP-200 program may be created in an off-line PC-compatible computer with a Windows®- based utility, then loaded into the AFP-200 EIA-232 port. The program may also be off-loaded to a PC at any time. High-speed data transfer completes upload or download in less than one minute. The PC pro- gram may also be used to access remote AFP-200 systems over dial-up phone lines, providing detail status information and history file search/sort. 3. AUTOPROGRAM 1. PLEASE WAIT O= CLR 1 = AUTO 2= POINT 2. 3= PASSWD 4= MESSAGE 5=ZONES 6 = SPL ZONES 7= SYS 8 =CHECK DN-3783 -Page 3 of 4 AGENCY LISTINGS AND APPROVALS See page 1 for listing agencies and file numbers. These listings and approvals apply to the basic AFP-200 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. SPECIFICATIONS Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. • Total Internal 24 VDC Power -5.0 A (total shared power). ti' High-ripple regulated power: 1.5A (suitable for EIA-485 devices, except ACM-SR); 1.0 A maximum standby. ti' Non-resettable power: 500 mA. V Four-wire smoke detector power: 500 mA. t/ Four built-in notification circuits: • NAG Circuit 1: 2.25 A. • NAG Circuits 2-4: 2.25 A (shared total). NOTE: with optional APS-6R Power Supply NAG circuits 3 & 4 are expanded to 3.0 A (8.0 A total power). Battery charger range: 7 AH -18 AH. Charge high rate: 29.1 V. Float rate: 27.0 V. • Relay contact rating: 2.0 A @ 30 VDC. • Cabinet dimensions: 16.125" (40.9575 cm) high x 14.5" (36.83 cm) wide x 5.5" (13.97 cm) deep. SYSTEM CAPACITY • Total programmable input/output points: 301 • Intelligent detectors: 99 Addressable monitor/control modules: 99 Programmable NAG circuits in panel: 4 • Programmable software zones: 99 Programmable remote relay/annunciator points: 99 • LC0-80 annunciators per system: 4 ACS annunciators per system: 10 CONTROLS AND INDICATORS 6 LED indicators: AC Power; Fire Alarm; Pre-Alarm; Super- visory/Security; Alarm Silenced; System Trouble. 21 Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; 12-key Alpha pad; 4 cursor keys; Enter. LCD Display: 80 characters (4 x 20) with long-life LED backlight. COMPATIBLE INTELLIGENT DEVICES CPX-751: Low-profile ionization detector. SDX-751: Low-profile photoelectric detector. SDX-551TH: Photoelectric with thermal element. HPX-751: HARSH™ Hostile Area photoelectric detector. FDX-551: Fixed thermal (heat) sensor. FDX-551 R: Fixed and rate-of-rise thermal sensor. CPX-551 DUCT: Ionization smoke detector (for duct use only). SDX-551 DUCT: Photoelectric smoke detector (duct use only). B710LP: Detector base, low profile. B224RB: Intelligent relay base, low profile (low-profile only). B224BI: Intelligent isolator base, low profile (low-profile only). B710HD: HARSH™ detector base {HARSH™ only). BX501: Detector base, classic (SDX-551TH, FDX-551/R only). B501 BH: Sounder base (classic or low-profile). BH501 BHT: Sounder base with temporal sounder (classic or low-profile). B524RB: Intelligent relay base (SDX-551TH, FDX-551/R only). B524BI: Intelligent isolator base (SDX-551TH, FDX-551/R only). 8501: Detector base, flangeless (classic or low-profile). DHX-501: Duct housing with alarm relay. DHX-502: Duct housing without alarm relay. continued next column ... Page 4 of 4 -DN-3783 MMX-1: Monitor module. MMX-2: Two-wire detector monitor module. MMX-101: Miniature monitor module. CMX-2: Control module. NBG-12LX: Advanced manual fire alarm station, addressable. BGX-101L: Classic manual fire alarm station, addressable. ISO-X: Isolator module. XPS Series: Transponders (see data sheet DN-6625). COMPATIBLE DEVICES, EIA-232 Port (see data sheets) PRN Serles: SO-column printer. VS4095/S2: Printer, 40 column, 24 volts. Mounted in exter- nal backbox (order from Keltron, Inc.). CRT-2: Video display terminal. NAM-232: Network Interlace Module to NOTl•FIRE•NET wire or fiber models. COMPATIBLE DEVICES, RS-485 Port (see data sheets) ACS Serles: Remote Serial Annunciator/Control systems. LCD-80: Remote LCD display. LDM Series: Remote custom graphic driver modules. ACM-SR: Remote relay module. Eight Form-C relays. NIB-96: Network Interlace Board. RPT-485: Series Repeater, isolator and/or fiber-optic modem. UDACT: Universal Digital Communicator. PRODUCT LINE INFORMATION BEAFP-200G: Basic AFP-200 equipment kit. Includes main board with display and keypad, door, hardware and manual. Backbox (SBB-4X or SBB-4XR) ordered separately. BEAFP-200R: Same as BEAFP-200G, but with red door. BEAFP-200GE: Same as BEAFP-200G but 230 VAC. BEAFP-200RE: Same as BEAFP-200R but 230 VAC. SBB-4X: AFP-200 backbox (no door), gray. SBB-4XR: AFP-200 backbox (no door), red. CAB-AM: Heavy-duty outer enclosure. Required for marine agency approved applications. 4XTM: Plug-in Transmitter Module. Provides municipal box and remote station connection. RTM-8: Plug-in Relay Transmitter Module. Provides eight Form-C relays, plus transmitter. 4XMM: AmmeterNoltmeter. TR-4XG: Gray Trim Ring for semi-flush mounting (TR-4XR for red). DP-AFP200: Full-length dead-front panel (required for Cana- dian applications). PS-1270: Battery, 12 volt, 7.0 AH, (two required). PS-12120: Battery, 12 volt, 12.0 AH, (two required). PS-12180: Battery, 12 volt, 18.0 AH (two required). APS-6R: 6.0 A expansion supply (requires 88-17). BB-17: Battery box, required for PS-12180, or if APS-6R is used. 411 Series: Digital Alarm Communicator/Transmitter. VeriFire-200: Programming kit for PC. Includes diskette, cable, and instructions. ROM-AFP200SP: Spanish language kit. Includes software IC, manual, and labels. ARCHITECTURAL/ ENGINEERING SPECIFICATIONS Specifications are available on CD-ROM with NOTIFIER's Speci•FireTM software. Contact NOTIFIER for details. c...\ c... c.. LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:164 Control Units (Non High-Rise) Page 1 of 1 Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Model AFP-200 fire alarm control unit. Local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 4XTM RTM-8 DP-AFP200 TR-4XG MMX-1, -101 ISO-X N-ELR CRT-2 VS4095/5 CMX-1 BB-17 AVPS-24 NAM-232 4XMM Transmitter Module Relay Module Dress Panel Trim Ring Monitor Module Loop Isolator Module EOL Resistors Terminal with Keyboard Printer Control Module Battery Box Power Supply Network Adapter Module Meter Module In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Suitable for central station (PPU) service when used with separately listed compatible DACT. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition. Refer to manufacturer's Installation Manual for details. • Also suitable for releasing service. For releasing application, Models NR-45 battery charger and AVPS-24 power supply shall not be used. Please contact the manufacturer for action. *Rev. 02-24-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 2, 2001 BEN HO, Supervising Deputy Program Manager Listing Expires June 30, 2002 C C C ~NOTIFIER~ WFIRE SYSTEMS GENERAL The NOTIFIER FSP-751 (photo) and FSl-751 (ion) are ana- log, addressable, low-profile (height measures only 1.66"/ 42.164 mm) smoke detectors designed for the entire line of Intelligent systems from NOTIFIER. The FSP-751T photo model includes a built-in thenmal (heat) detection device. If either condition (smoke or heat) is detected, the device will alanm. The addressability of the FSP-751 and FSl-751 enables the control panel to provide firefighters with a pinpoint descrip- tion of where the fire is located. The FSP-751 and FSl-751 are also analog devices. The control panel is capable of not only knowing the detector's location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of its location. Analog devices continually send obscuration values to the con- trol panel. These values may be gathered so as to allow the control panel to detenmine if a detector has accumulated an excessive amount of dirt or dust. A "maintenance" required indication allows the installer to clean the smoke detector be- fore an unwanted false alarm occurs. The FSl-751 Intelligent Ionization Sensor incorporates a unique single-source chamber design to respond quickly and dependably to a broad range of fires. The FSP-751 Intelligent Photoelectric Sensor's unique opti- cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion sources. FlashScan® (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli--~ gent devices and certain NOTIFIER systems. Intelligent de-j vices communicate in a grouped fashion. If one of the de-~ vices within the group has new infonmation, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FlashScan® is a registered trademark of NOTIFIER. FEATURES Sleek, low-profile design (height only 1.66"/42.164 mm). Common base for both photo and ion detectors. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Rotary 01 to 159 address switches (01 to 99 on traditional systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. December 15, 2000 DN-6714 • H-200 FSl-751 and FSP-751/751T Low-Profile Intelligent Plug-in Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices ® (@c I ~~i!i°~~: 11 ;jj Marshal I.:: 7272-0028:206 LISTED CS308 (FSP-751l-751T} S1115 MARYLAND State Fire Marshal 2020 (FSl-751) 2013 (FSP-751l-751T} <8> Approved -~-- 7271-0028:201 (FSl-751) MEA 277-99-E (FSP-751I -7517 only) FSP-751Twith B710LP base FSP-751 with RMK400 recessed mounting kit Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan® systems only). Built-in functional test switch activated by external mag- net. Optional relay, isolator, or sounder bases. Listed to UL 268. SPECIFICATIONS Size: 1.66" (42.16 mm) high x 4.1" (104.14 mm) diameter. Shipping weight: 3.6 oz. (104 g). Operating temperature: 0°C to 49°C (32°F to 120°F). This document is not intended to be used for installation purposes. We try to keep our product information up-to...(jate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203} 484-7118 ISO 9001 CERTIFIED (ffi} N OTI Fl ER" 12 Clintonville Road, Northford, Connecticut 06472 llllrflllNI I MMIFlnlllNI DN-6714•12/15/00 -Page 1 of4 UL listed velocity range: ION: 0 -1500 fpm (0 -7.62 ml sec). PHOTO: O -4000 fpm (0 -20.32 mlsec). Relative humidity: 10% -93% noncondensing. ELECTRICAL SPECIFICATIONS: Voltage range: 15 -32 volts DC peak. Standby current -ION: 200 µA@ 24 VDC (without com- munication); 300 µA@ 24 VDC (one communication every 5 seconds with LED enabled). Standby current -PHOTO: 250 µA @ 24 VDC (without communication); 360 µA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA@ 24 VDC ("ON"). Air velocity ratings: FSP-751 & FSP-751T: to 4,00011./min. (1219.2 m/min.). FSl-751: to 1,50011./min. (457.2 m/min.). BASES AVAILABLE: B710LP: 6.1" (154.94 mm) diameter. B501: 4.1" (104.14 mm) diameter. B501 BH or B501 BHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm'). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A@ 110 VDC inductive; 1.0 A@ 30 VDC in- ductive. Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). B524BI Isolator Base: Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). Maximum: 25 devices between isolator bases. Duct applications: FSP-751 and FSP-751T are Listed for use in air ducts. See Duct Application Guide A05-1004 for details on pendant-mount applications. NOTE: These prod- ucts are NOT Listed for use inside a duct smoke detector housing. INSTALLATION The FSP-751 and FSl-751 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and re- move detectors without using a ladder. Mount base on a box which is at least 1.5" (38.1 mm) deep. Suitable mounting base boxes include: 4" (101.6 mm) square box. 3-112" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B501BH base, use a 4" (101.6 mm) square box. With B224RB or B224BI base, use a 3-112" (88.9 mm) octagonal box, or a 4" (101.6 mm) octagonal or square box. SMOKE GUARD Cover: 16 gauge perforated steel (3/16" [4.7625 mm] dia. perforations on 1/4" [6.35 mm] staggered centers). 51 % open. SDG-773 is 3" (76.2 mm) deep by 7" (177.8 mm) wide. Frame: 3/4" x 314" (19.05 x 19.05 mm) angle, 14 gauge solid steel. All guards are supplied with the fol/owing: 1) Guards fasten to mounting frame with No. 10124 x 318" (9.525 mm) long Allen-head screws (10/24 spanner-head screws and tool option at extra cost). PRODUCT LINE INFORMATION Description Model FSl-751 Low-profile intelligent ionization sensor. Must be mounted to one of the bases listed below. FSP-751 Low-profile intelligent photoelectronic sensor. Must be mounted to one of the bases listed be- low. FSP-751T Same as FSP-751 but includes a built-in 135"F (57"C) fixed-temperature thermal device. BASES: B710LPBP Standard U.S. low-profile base, pkg. of 10. B501BP Standard European flangeless base, pkg. of 10. B501 BH Sounder base, includes B501 base above. B501 BHT Same as B501BH, but includes temporal sounder. B224RB Intelligent relay base. B224BI Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: SDG-773 Smoke Detector Guard. This guard is mechani- cally compatible with both FSl-751 and FSP-751 detectors. It is UL-compatibility listed with the FSP-751 (file UL S5515). /tis NOT UL-compat- ibility listed with the FSl-751. F110 Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FlashScan detectors. RA400Z* Remote LED annunciator. 3 -32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with 8501 base only. RMK400 Recessed mounting kit. For use with 8501 base only. SMB600 Surface mounting kit for use with B710LP. M02-04-01 Test magnet. M02-09-00 Test magnet with telescope stick. XR-2 Detector removal tool. Allows installation and/ or removal of FlashScan Series detector heads from base in high ceiling installations. XP-4 Extension pole for XR-2. foot sections. •supported by B710LP and B501 bases only. OPTIONAL SDG-773 Smoke Guard Comes in three five- (1.905 cm),--------------------------------------------------------------, (1.905 cm) ~\ 7"(17.78cm) \.r;;4• :~ tf Celling or Wall 2) Standard finish: "Cool Tan" baked enamel. MOUNTING DIAGRAM ► SDG-773 Smoke Guard 3": (7.62 cm): MODEL NO. SDG-773 4762sdgm.wmf , ___ L_ ___________ ____, Page2of4-DN-6714•12/15/00 C C C DETECTORS, EXPLODED VIEW SENSOR COVER ~ {) -COVER lQ.l REMOVAL TABS -- SENSOR __ SCREEN ~===~µ===~ ilJ □ 6714exp1,wrnl .... FSP-751 and FSP-751T Photo TEST MAGNET POSITIONING PAINTED SURFACE □ MAGNET TEST MARKER D []J TEST MAGNET 6714mag1.wmf .... FSP-751 and FSP-751T Photo ~:::::::::::::::::::::::::::::::::~~:::::::::::::::::::::::::::::::~SENSOR ,,Lz=°~===°::=l~~====='a'S::COVER @ {) -COVER {) REMOVAL TABS ~ SENSOR ~SCREEN ! SENSOR CONTACTS SENSING CHAMBER _.--SENSING CHAMBER ilJ □ 6714a~p2.wml .... FSl-751 Ion PAINTED SURFACE D []J TS 6714mag3.tif .... FSl-751 Ion DN-6714 • 12/15/00 -Page 3 of 4 WIRING DIAGRAMS Listed Compatible CONTROL PANEL + REMOTE ANNUNCIATOR + -------------------------------------------~ OPTIONAL RETURN LOOP -------------------------------------------------------+ REMOTE ANNUNCIATOR + A FSP-751 and FSP-751T Photo /£..CAUTION/ T DO NOT LOOP wire under terminals 1 or 2. Break wire run to provide supervision of connections. +~~---,-----/--------- 1 Control Panel + I ~-----'~---------''----/-----'I ______ STYLE6llOPT/ONALWIRING ----~-----~ ____ _ A FSl-751 Ion Page 4 of 4 -DN-6714 • 12/15/00 L LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE ARE MARSHAL ARE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-1209:192 Photoelectric Smoke Detector System Sensor, 3825 Ohio Avenue, St. Charles, IL 60174 Contact: Andrej Nikolic (630) 377-6674 Page 1 of 1 Models FSP-751 and FSP-751T photoelectric type smoke detectors. Each unit consists of resistors, capacitors, diodes, transistors, microprocessor, LED, photoelectric chamber, mounted on a printed wiring board inside an enclosure which has an opening to the outside air. Model FSP-751 T employs an integral heat sensor. This sensor is intended for use only as a supplemental to the smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. L !ARKING: listee's name, product number, electrical rating and UL label. L APPROVAL: listed as smoke detectors for use with Notifier's separately listed compatible bases and fire alarm control units. Suitable for open areas with air velocities between 0-4000 fpm. 08-30-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to iistee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 7, 2001 BEN HO, Supervising Deputy Program Manager Listing Expires June 30, 2002 C' c... LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0028:173 Misc. Devices/Control Unit Accessories Page 1 of 1 Notifier. A Pittway Company. One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Models BX501, B610LP, B612LP. B614LP. B616LP and B710LP detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, product designation, electrical rating and UL label. Listed as detector bases for use with separately listed compatible detectors. 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 4, 2001 BEN HO, Supervising Deputy Program Manager Usting Expires June 30, 2002 C C C ~NOTIFIER® WFIRE SYSTEMS GENERAL The FST-751 Serles intelligent thermal detector is used with the intelligent NOTIFIER Fire Alarm Systems to mea- sure thermal levels caused by a fire and report the analog level of the thermal measurement to the control panel. The use of analog information provides significant ben- efits to the end user, installer, and service personnel in ways which are not possible with a conventional type sys- tem. Since this detector is addressable, it helps firefighters to more quickly locate a fire in its early stages. FlashScan (patent pending) is a new communication pro• tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel's CPU stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-751R), 15°F (8.3°C) per minute. Factory preset at 135°F (58°C). Addressable by device. Direct 01 -159 entry of address (01 -99 on traditional systems). Two-wire loop connection. Visible LEDs "blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (Two bicolor LEDs). LEDs blink green in Normal condition and tum on steady red in Alarm. Integral communications and built-in device-type iden- tification. Remote test feature from the panel. Built-in functional test switch activated by external mag- net. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Listed to UL 521. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. SEMS screws for wiring of the separate base. 94-5V plastic flammability rating. September 15, 2000 DN-6716 • H-210 FST-751 Series Intelligent Thermal (Heat) Detectors with FlashScan ™ Section: lntelligenUAddressable Devices ® I California <8> State Fire Marshal 7270-0028:196 LISTED Approved MARYLAND (AFC-600) S747 State Fire Marshal Permit 2011 MEA 278-99-E Remote LED output connection to optional RA400Z remote LED annunciator. Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400) base mounting kits. APPLICATIONS Use thermal detectors for protection of property. For further information call NOTIFIER for manual 156-407- 00, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. CONSTRUCTION These detectors are constructed of Bayblend® in an off-white color. The FST Series plug-in intelligent thermal detector is de- signed to commercial standards and offers an attractive ap- pearance. INSTALLATION The FST Series plug-in intelligent thermal detector uses a separate base to simplify installation, service, and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box which is at least 1.5" (38.1 mm) deep. Suitable boxes include: • 4" (101.6 mm) square box. FlashScan™ is a trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-lo-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 @) N OTI Fl ER" 12 Clintonville Road, Northford, Connecticut 06472 ISO 9001 CERTIFIED INIINl!IINC l MMIIAfflUNC ON-6716 • 09/15/00 -Page 1 of 2 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With 85018H or B501BHT base, use a 4" (101.6 mm) square box. With B224RB or 822481 base, use a 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box, or a 4" (101.6 mm) square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B'? wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and iso- lator bases. OPERATION Each FST Series uses one of 159 possible addresses (99 on traditional systems) on a control panel SLC loop. It responds to regular polls from the control panel and it reports its type and status, including the analog level of its heat-sensing elements. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm analog level. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel (detector blink is optional). The FST Series offers features and performance that represent the latest in thermal detector technology. SPECIFICATIONS Size: Diameter installed in 8710LP: 6.1" (154.94 mm); Diameterinstalledin8501: 4.1"(104.14mm). Height: 1.66" (42.16 mm). Weight: 5 oz. (150 gm). Operating temperature: -4"F to 100'F (-20'C to 38'C). Operating humidity range: 10% to 93% relative humidity, noncondensing. Operating voltage/current range: 15 -28 V (Peak DC), 5 mA current for visible LEDs latched on. Detector standby current: 300 µA @ 24 VDC (one com- munication every 5 seconds with LED blink enabled). For bases 8224RB or 822481: < 700 µA @ 24 VDC (includes detector). Sensor: electronic, dual thermistors. Fixed temperature setpoint: 135'F (57'C). WIRING DIAGRAM REMOTE ANNUNCIATOR + +f-f---~ Control Panel Rate-of-rise option: 1 S'F (8.3'C) per minute. B224RB relay base: Screw terminals: up to 14 AWG (2.00 mm'). Relay type: Form-C. Ratings: 2 A @ 30 VDC resis- tive; 0.3 A@ 110 VDC inductive; 1.0 A@ 30 VDC inductive. Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. See Note 2 (left column). B224BI isolator base: Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. Maximum: 25 devices between isolator bases. See Note 2 (left column). PRODUCT LINE INFORMATION Model Description FST-751 Intelligent thermal sensor. FST-751R Intelligent thermal sensor with rate-of-rise fea- ture. BASES: B710LPBP Standard U.S. style low-profile base, package often (10). B501BP Standard European flangeless base, pack- age of ten (10). B501BH Sounder base, includes B501 base above. 24 VDC, 85 dBA internal horn. B501 BHT Same as B501 BH but with temporal pattern sounder. B224RB Intelligent relay base. B224BI Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: RA400Z' Remote LED annunciator. 3 -32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with 8501 base only. M02-04-00 Test magnet. •supported by 8501 and B710LP base only. ARCHITECTS' & ENGINEERS' SPECIFICATIONS Specifications are available on these and all NOTIFIER prod- ucts. Please contact NOTIFIER. ------1 I ~----/---- I I ---t-ir--... I I I I I I I I I I I ~-------~ ~---/---~ I I -------------------------/-----~ + ______ STY)...E6/7OPTIONALWIR/NG ____ 1 ___________ I 6714wlr2.lif Page 2 of 2 -DN-6716 • 09/15/00 C LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-0028:196 Heat Detector Page 1 of 1 Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Models FST-7 51 (fixed temperature) and FST-7 51 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. 135° F fixed temperature In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical ratings, and UL Inc. Label c... APPROVAL: Listed as heat detectors for use with Model B501 or B71 OLP base (CSFM Listing No. 7300-0028:173) and listee's separately listed compatible fire alarm control units. (_ 08-06-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 4, 2001 BEN HO, Supervising Deputy Program Manager Listing Expires June 30, 2002 C. (_ (.. LISTING No. CATEGORY: USTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0028:173 Misc. Devices/Control Unit Accessories Page 1 of 1 Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Models BX501, B61 OLP, B612LP, B614LP, B616LP and B71 OLP detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, product designation, electrical rating and UL label. Listed as detector bases for use with separately listed compatible detectors. 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: MAY 4, 2001 BEN HO, Supervising Deputy Program Manager Usting Expires June 30, 2002 C C ~NOTI Fl ER@ WFIRE SYSTEMS GENERAL FCM-1 Control Module -The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressability allows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 Relay Module -The FRM-1 Addressable Re- lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. lf one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScan sys- tems only. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all de- vices). High noise immunity (EMF/RFI). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01-159 for FlashScan, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices, The FRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to re- set four-wire smoke detector power. August 9, 2000 DN-6724 • H-230 FCM and FRM Series Control and Relay Modules with FlashScan '" Section: Intelligent/Addressable Devices ® @b9 I California State Fire Marshal ""' 7300-0028:202 LISTED CS669 <8> S3705 MARYLAND MEA State Fire Marshal Permit #2020 Approved 457-99-E (} 0 ~ ~ 0 0 9 0 ~ 578910 8 4 11 1 3 12 2 13 7 101514 2 TEN~\789 3 6 4 3 5 2 4 ONE~ O LOOP ADDRESS ~ 0 0 ~ 0 FCM-1 Module (See wiring diagram Fig. 5 for FRM-1) CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM provides two Form-C dry contacts that switch together, OPERATION Each FCM or FRM uses one of 159 possible module ad- dresses on a SLC loop. II responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On Flash Scan™ is a trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED @) N OTI Fl ER• One Fire-Lite Place, Northford, Connecticut 06472 INIIM'IIINC I MANDFAmllNI DN-6724 • 08/09/00 -Page 1 of 4 command, it activates its internal relay. The FCM super- vises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The discon- nection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The ex- ternal power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. A built-in magnetic test switch is provided to simulate a short circuit on the NAG to test the FCM-1. SPECIFICATIONS lor FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 390 µA (LED flashing). External supply voltage {between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32"F to 120"F (0"C to 49"C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. SPECIFICATIONS lor FRM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 µA (LED flashing). EOL resistance: not used. Temperature range: 32"F to 120"F (0"C to 49"C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS lor both FCM and FRM models Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30VDC 3.0A Resistive Coded 30VDC 2.0A Resistive Non-Coded 110 VDC 0.9A Resistive Non-Coded 125 VAC 0.9A Inductive (UR= 5 ms) Coded 30VDC 0.5A Inductive (UR= 2 ms) Coded 30VDC 1.0A Inductive (PF = 0.35) Non-Coded 125 VAC 0.5A PRODUCT LINE INFORMATION 6724rate.lbl FCM-1 FRM-1 Intelligent Addressable Control Module. Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) op- eration of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier -required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. 1 MOUNTING DIAGRAMS Page 2 of 4 -DN-6724 • 08/09/00 Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT C C C [j;JJ CAUTION ◄ The Face Plate .... WIRING DIAGRAMS "T The following wiring diagrams are provided: 1) FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. 2) FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. 3) FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. 4) FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. 5) FRM-1: Relay module wiring diagram. OE-ENERGIZE UNIT PRIOR TO SERVICING T Fig. 1 FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Module polarities are shown in alarm. 47K EOL Resistor ELR-47K \ ~-~ ---UL listed EOL Relay shown energized 24 VDC coil A77-716B TO NEXT control module or EOL Relay. ONE RELAY REQUIRED for each circuit. Some control panels have the RELAY BUil T IN and do not require external wiring. Refer to the NOTIFIER manual. 24VDC POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection with battery backup. T Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supeivised and power limited. Module polarities are shown in alarm. ---UL listed EOL Relay shown energized 24 VDC coil A77-716B TO Next Device • TO NEXT control module or EOL Relay. • ONE RELAY REQUIRED for each circuit. • Some control panels have the RELAY BUILT IN and do not require external wiring. Refer to the NOTIFIER manual. Communication Line 32 VDC max. T • t d-pair is recommended. (-) FROM Panel ,f.:X:X:::,(_ ( +) or Previous Device 24 voe Circuit I DONOTLOOPwire on terminals 3 & 4. Break wire to provide supervision of connections. (-) (+) 24VDC POWER SUPPLY Power Supply: Isolated, regulated, power-limited perNFPA 70. Listed for fire protection with battery backup. DN-6724 • 08/09/00 -Page 3 of 4 T Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised. Wires must be supervised per NFPA. Module polarities are shown in alarm. 47K EOL Resistor ELR-47K '-,._ TO Next Device Speaker Switching Circuit: NFPA STYLE W Speakers must be listed for fire protection. Communication Line TO Next 32 VDC max. Twisted-pair recommended. ( -FROM Panel n:::><:::><::::::< ( +) or Previous Device Audio Circuit I DONOTLOOPwlre on temiinals 3 & 4. Break wire to ensure supetvision of connections. H AUDIO AMPLIFIER 70.7 VRMS max. Use only models AA-30, AA-100, or AA-120. Amplifier must provide wiring supervision per NFPA. SUPERVISION Refer to the Relay Contact Rating table for maximum load. Control Module Last module must return wires for supervision. 6724wlr3.wmf T Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised. Wires must be supervised per NFPA. Module polarities are shown in alarm. EOL Resistor is internal at terminals 8 & 9. Bypass Capacitors: A2143-20, 100 µf, 16 V, non-polarized,< 10 µA leakage. Speaker Switching Circuit: NFPA STYLE X Speakers must be listed for fire protection. Communication Line TO Next 32 VDC max. Twisted-pair recommended. (-) FROMPanel f-::X::X::::,(J([:i+J)_: or Previous r Device Audio Circuit I DONOTLOOPwire on terminals 3 & 4. Break wire to ensure supervision of connections. H + AUDIO AMPLIFIER 70.7 VRMS max. Use only models AA-30, AA-100, or AA-120. Amplifier must provide wiring supervision per NFPA. ~ SUPERVISION Refer to the Relay Contact Rating table for maximum load. Control Module Last module must return wires for supervision. 6724wlr4.wmf NOTES regarding AUDIO AMPLIFIER in Figures 3 & 4 above. 1) Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailed information. 2) When a 70.7 V audio amplifier is used, terminals 1 and 2 are power-limited, while terminals 3 through 9 are non-power-limited. In this case, the CBSOO barrier is required. Otherwise, all terminal wiring is power-limited. The CBSOO includes a label indicating which terminals are non- power-limited. This label MUST BE PLACED adjacent to the nameplate label, which is on the module housing. ~ ~ ~ ' \ ' \ ' \ , ..... TO Next I l l l l l (+) I Device \ I \ ' \ I I ♦------V _____ l,,..I " ,_ , RELAY cJ MODULE <:o --, ' 0 oO 6724wlr5.wmf Page 4 of 4 -DN-6724 • 08/09/00 ~ ~ ~ r, I \ I \ I \ \ I I I I (+) (-) FROM Panel or Previous Device \ \ I \ I \ I , r-V---~.l.-----V------◄ f--Communication Line I (" ---) ---32 VDC maximum. Shielded twisted-pair is recommended. ◄ Fig. 5 FRM-1: Relay module wiring diagram. Connect modules to listed compatible control panels only. Module does NOT supervise controlled circuits. C. <... (_ LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0028:202 Misc. Devices/Control Unit Accessories Page 1 of 1 Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 Models FMM-1, FMM-101 . FZM-1, FSM-101, FDM-1 * monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name. product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. •Rev. 05-02-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 18, 2001 BEN HO, Supervising Deputy Program Manager Listing Expires June 30, 2002