Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2502 WELLSPRING ST; ; CBRA2017-0284; Permit
Permit Print Date: 08/29/2018 Job Address: (city of Carlsbad Permit No: CBRA2017-0284 Permit Type: Parcel No: 2502 Wellspring St BLDG-Associated Permit Residentia 2081913900 Work Class: Lot II: Single Family Detached 182 Status: Applied: Closed -Finaled 11/01/2017 12/27/2017 Valuation: Occupancy Group: II Dwelling Units: Bedrooms: $535,359.24 1 5.00 Reference II: Construction Type: Bathrooms: Orig. Plan Check II: DEV2016-0039 VB e,-< ,~-0% Issued: Permit Finaled: Inspector: CRenf Plan Check II: 5.50 . PC150042 ✓ PC2016-0067 Final Inspection: 8/29/2018 3:27:36PM Project Title: THE VISTAS Description: THE VISTAS: PHASE 10 / LOT 182 / PLAN 3 / 3,352 SF LIV/ 425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM Applicant: Owner: TOLL BROS INC JOANN EPSTINE RANCHO COSTERA LLC -2483-INACTIVE 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFO) FEE ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG TRAFFIC IMPACT Residential Single Family w/in CFO TRAFFIC IMPACT Residential Single Family w/in CFD WATER METER FEE l" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $33,438.62 Total Payments To Date: $30,638.62 Contractor: TOLL BROS INC 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 Balance Due: $2,800.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $2,145.00 $1,381.38 $1,723.10 $96.00 $170.00 $110.00 $224.00 $9,743.54 $22.00 $5,029.00 $1,304.00 $934.00 $69.60 $238.00 $2,800.00 $2,800.00 $352.00 $4,169.00 $128.00 PERMIT INSPECTION HISTORY REPORT (CBRA2017-0284) Permit Type: BLDG-Associated Permit Residential Application Date: 11/01/2017 Owner: Work Class: Single Family Detached Issue Date: 12/27/2017 Subdivision: Status: Closed -Finaled Expiration Date: 06/25/2018 Address: IVR Number: 7401 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 08/1312018 08113/2018 0812912018 0812912018 August 29, 2018 Checklist Item BLDG-Building Deficiency BLDG-23 Gas/Test/Repairs 061550-2018 Checklist Item BLDG-Building Deficiency BLDG-Electric Meter 066658-2018 Release BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 068498-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS RANCHO COSTERA LLC - 2483-INACTIVE 2502 Wellspring St Carlsbad, CA 92010-5604 Reinspection Passed Yes Passed Yes Passed Yes Passed Yes Yes Yes Yes Yes Complete Complete Complete Complete Page 2 of 2 _ PERMIT INSPECTION HISTORY REPORT (CBRA2017-0284) Permit Type: BLDG-Associated Permit Residential Application Date: 11/01/2017 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 12/27/2017 Subdivision: Status: Closed -Finaled Expiration Date: 06/25/2018 Address: 2502 Wellspring St Carlsbad, CA 92010-5604 IVR Number: 7401 Scheduled Actual Primary Inspector Reinspection Complete Date Start Date Inspection Type Inspection No. Inspection Status 03/08/2018 03/08/2018 BLDG-21 051054-2018 Passed Chris Renfro Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/05/2018 04/05/2018 BLDG-11 053918-2018 Passed Paul Burnette Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 053919-2018 Passed Paul Burnette Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05/21/2018 05/21/2018 BLDG-15 058580-2018 Passed Tim Frazee Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/08/2018 06/08/2018 BLDG-13 Shear 060647-2018 Passed Chris Renfro Complete Panels/HD (Ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/15/2018 06/14/2018 BLDG-84 Rough 060799-2018 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 06/20/2018 06/20/2018 BLDG-17 Interior 061548-2018 Passed Chris Renfro Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-18 Exterior 061549-2018 Passed Chris Renfro Complete Lath/Drywall August 29, 2018 Page 1 of 2 RECORD COPY Building Division INSPECTION RECORD: Ii'! •~SPECTION RECORD CARD WITH APPROVED CBRA2017-0284 I ~T ¼ _\<g~ 2502 WELLSPRING ST THE VISTAS: PHASE 10 / LOT 182 / PLAN 3 / 3,352 SF LIV/ 425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM I )ANS MUST BE l<EPT ON THE JOB 0 CALL BEFORE 3:00 pm FOR NEXT WORI( DAY INSPECTION • o·EV2016-0039 PC2016-0067 2081913900 11/9/2017 0 FOR BUILDING INSPECTION CALL: 760-602-2725 "Request lnspe CBRA2017_-oia4 IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention Planning/Landscape CM&I (Engineering Inspections) #12 REINFORCED STEEL #66 MASONRY PRE GROUT _{ 0 GROUT D WALL DRAINS #llJ TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR O CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR lATH #17 INTERIOR LATH & DRYWALL #24 #27 TUB & SHOWER PAN #23 □ GAS TEST OGAS PIPING #25 WATER HEATER #28 SOLAR WATER BLDG-FINAL CODI?# POOLS #51 POOL EXCAV / STEEL #52 PLUMBING #53 ELEC /CONDUIT/WIRING j ) EQUIPOTENTIAL BDND ih,5' PREPLASTER / FENCE/ ALARMS #57 GUNITE BLDG-FINAL REV 9/17 760-602-4660 7 60-94 4-8 463 760-438-3891 Ins ector Date Ins ector Allow 48 hours Allow 48 hours Call before 2 pm #33 #32OTEMPORARY #35 #38 SIGNS BLDG-FINAL #81 #82 DRVWALL,EXT lATH, OAS TES (17,18,23) #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) #85 T-Bar (14,24,34,441 BLDG· FINAL OCCUPANCY A/5 UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/AFINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURETEST MEDICAL GAS FINAL Date Date COPYOFCAnO tlEOUlr!EO Ins ector Ins ector Ins ector SEE BACK FOR SPECIAL NOTES Michael Baker INTERNATIONAL March 30, 2018 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Inspector: Vistas -Lots 178,179,180,181, & 182 City of Carlsbad Tract No. CT 13-03 JN 143824 Michael Baker International has performed a field survey on March 30, 2018 to field check the building footing forms for Lots 178-182 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial conformance, both horizontally (0.1 0'.:t.) and vertically (0.05'.:t.) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:IPDATA\143824_ROBERTSON RANCHIAOMINICORRESPNONCIFORM CERTSITOLL BRO_FORM_PA6_ CERT14_ 178-182.00C P LANNING ■ DESIGN ■ CONS TRUCTION 5050 Avenida Encinas, Suite 260, Carlsbad, California 92008 ff 760.476.9193 ff FAX 760.476.9198 Offices located throughout the Country ■ www.mbakerjntl com Location: \JV if /,1,., S /2. t .f l. Client: ----d .• iJ f e~s. Soil Engineer: Unit/Phase/Lots: l~itials:~ 'Date:~ -~"i :lnTtials: :::::7l1 , •• Date: ~'rz>~j,<ff I Initials: ~Jh Date: :~f~·i'; f~ Notes: 0 Project No.: i1 I 3302>-Jo AO _ Superintendent: i'([/.,1 Geologist: Author: R'I JJAi Contractor: Weather: (circle one) 68 ~ ~~j) Overcast Rainy FL C & lff. ~114--~or7 Footin Observation Summa : Report No.: / Day: (circle one) M r w r @ s s Foreman: I' '-t.>.!i ~ Other: ____ _ Permit No. P 0 /;;7"!) A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. A representative of LGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. -flLvat,l(J £1,u,.1~n OIi$, £41:{L fln;.,{);(Nc..C /Su,-....O;IJG /:ht,..4 o .. Jty ,,, tc.rrs 171!._.n~. Al>i(),. /fsl_, i:::z,. wz,. ~a~ '&O'f, ZO-S:: •• 1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete. 2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations, as necessary. /i I ; I' II (//If /'v't. 3}3oL :>, or LGCNau §~ Date f • t ·-....... ,,,11·"-!·itiiom----------,-------===='1""====;==== ....... -------~I ~\, Received by: A Technician Hours ~(l)OTING OBSERVATION :; ~-~I'~~~~::::_~ ,-· SUMMARY White -File Copy Print:// (~'-- Yellow -Client Copy Pink -Field Copy LGC VALLEY, INC. Geotechnical Consulting . Gold -ClienUAgency Copy Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941 -2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED INSPECTOR'S DAILY REPORT I SWIT Job No. 150314 I Date 4/04/2018 TYPE OF D Reinforced Concrete □ Structural Steel Assembly □ Quality Control INSPECTION Iii Post Tensioned Concrete □ Fire Proofing □ Wood Framing REQUIRED D Reinforced Masonry □ Asphalt □ Other Job Address Lot 181 Lot 182 & Lot 202 City Carlsbad , CA Job Name Vistas @ Robertsons Ranch Permit No. CBRA2017-0283-0284-0273 I 1ssued By Carlsbad Type of Structure Residential Architect N/A Material Description (type, grade, source) Engineer Ian R. Waddell Phase #10 Tract# 3663 Contractor Toll Brothers Inspector's Name Raymond Mitchell Subcontractor Frontier TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON· SAMPLE INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS /WELD MADE H.T. BOLTS TORQUED) CHECKED ETC. Observed reinforcing steel and tendons for lot #s 181 ,182 & 202 all per details on sheet 4TR, 3SCR & 1XMR of approved plans. Verified reinforcing steel for size, grade, lap, locations and clearances . Checked locations of embedded items and sleeves. All work observed is in accord ance to approved plans and specs. Work is complete CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND APPLICABLE SECTION OF THE GOVERNING BUILDING LAWS. F REGISTERED INSPECTOR PT Concrete 8343448/3352 ICC SPECIALTY NO. AGENCY · CONTINUED ON NEXT PAGE 0 PAGE TIME IN TIME OUT 3:00pm 5:30pm Approved By Project Superintendent White -Office Copy • Canary -Accounting Copy • Pink-Inspector's Copy • Goldenrod -Jobsite Copy OF SAMPLES sm F-002 S:\FORMS\DAILY REPORT TEMPLATES & FORMS\Registered Inspector's Daily Report Template.dot ©Southwest Inspection & Testing, Inc.