Loading...
HomeMy WebLinkAbout2459 WELLSPRING ST; ; CB160689; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-04-201 6 Residential Perm it Permit No: CB160689 ., Building Inspection Request Line (760) 602-2725 Job·Address: 2459 WELLSPRING ST CBAD Permit Type: RESDNTL Sub Type: SFD Status: ISSUED Applied: 02/22/2016 Entered By: SLE Parcel No: 2081927700 Lot #: 147 Valuation: $458,430.00 Constuction Type: 58 Occupancy Group: # Dwelling Units: Bedrooms: 1 4 Reference #: CT130003 Structure Type: SFD Bathrooms: 4.5 Plan Approved: 03/04/2016 Issued: 03/04/2016 Inspect Area: Orig PC #: PC 150041 THE RIDGE: PHASE 2 / PLAN 2 Plan.Check #: PC160015 Project Title: 2,957 SF LIV/ 413 SF GARAGE/ 182 SF PATIO Applicant: RANCHO COSTERA LLC 725 W. TOWN AND COUNTRY DR 200 ORANGE CA 92868 760-720-5485 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Ch~ck Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee STD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee . Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $1 ,900.51 $0.00 $1,330.36 ($500.00) $0.00 $59.60 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,934.00 FS1 $0.00 $0.00 $19.00 $0.00 Total Fees: $27,387.36 Total Payments to Date: Inspector: AC Jl Date: Owner: RANCHO COSTERA LLC 725 W. TOWN AND COUNTRY 200 ORANGE CA 92868 760720-5485 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (31041 93) License Tax (4304193) Traffic Impact Fee (3105541 ) Traffic Impact Fee (4305541 ) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $27,387.36 Balance Due: FS1 $0.00 $356.00 $4,963.00 $1,710.27 $8,343.43 $0.00 $0.00 $0.00 $2,690.00 $0.00 $0.00 $276.00 $89.00 $113.19 $0.00 $0.00 $0.00 $0.00 $2,103.00 $0.00 $0.00 $27,387.36 $0.00 Clearance: ------ NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Car1sbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-04-201 6 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW160093 Job Address: Permit Type: 2459 WELLSPRING ST CBAD SWPPP Status: Parcel No: 2081927700 Lot#: 147 Applied: Reference #: CB#: CB160689 Project Title: THE RIDGE: PHASE 2 / PLAN 2 Applicant: RANCHO COSTERA LLC 725 W. TOWN AND COUNTRY RD 200 ORANGE CA 92868 Emergency Contact: GREG DEACON 760-637-9083 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Entered By: Issued: Inspect Area: Tier: Priority: Owner: RANCHO COSTERA LLC 725 W. TOWN AND COUNTRY 200 ORANGE CA 92868 760720-5485 ISSUED 02/22/2016 SLE 03/04/2016 1 M $0.00 $228.00 $0.00 $228.00 Total Fees: $228.00 Total Payments To Date: $228.00 Balance Due: FINAL APPROVAL DATE-CLEARANCE. __ _ SIGNATURE~~-------- $0.00 Inspection List Permit#: CB160689 Type: RESDNTL SFD Date Inspection Item Inspector 10/19/2016 89 Final Combo 10/19/2016 89 Final Combo AEK 10/12/2016 33 Service Change/Upgrade AEK 10/12/2016 39 Final Electrical 07/26/2016 82 Drywall/Ext Lath/Gas Test PB 07/18/2016 84 Rough Combo PB 07/11/2016 13 Shear Panels/HD's AEK 07/08/2016 13 Shear Panels/HD's PB 06/16/2016 15 Roof/Reroof PB 06/15/2016 15 Roof/Reroof PB 04/18/2016 81 Underground Combo PB 04/11/2016 21 Underground/Under Floor PD 04/11/2016 22 SewerM/ater Service PD 04/07/2016 21 Underground/Under Floor PB Thursday, October 20, 2016 Act RI Fl AP RI AP AP AP NR AP NR AP AP AP NR THE RIDGE: PHASE 2 / PLAN 2 2,957 SF LIV/ 413 SF GARAGE/ 182 SF P Comments PM PLEASE AM PLEASE Page 1 of 1 ~h). ,~'CITY 0~ CB160689 2459 WELLSPRING ST THE RIDGE: PHASE 2 / PLAN 2 CARLSBAD Building Division 'INSPECTION ·RECORD 2,957 SF LIV/ 413 SF GARAGE f 182 SF PATIO RESDNTL SF0 Lot#: 147 RANCHO COSTERA LLC 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB ---·----- li'l CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION li'l FOR BUILDING INSPECTION CA~760-602::l_Z25 RECORD COPY OR GO TO: www.CarJsbadca.gov/BuUdlnq AND CLICK ON HRequest lnspectJon" DATE: Plan~ndscape 760-94~463 CM&I (Engineering Inspections) 760-438-3891 Fire Prevention 760-602-4660 REINFORCED STEEL #66 MASONRY PRE GROUT □GROUT □ WALL DRAINS #10 TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME □ FLOOR □ CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWAU #51 POOLEXCA/STEEL/BOND/FENCE #55 PREPLASTER/FINAL #22 □ SEWER & BL/CO O PL/CO #21 UNDERGROUND □WASTE O WTR #24.. 10.tJ>JJLO..WASILJJ..WIB..._. _____ _ #27 rue & SHOWER PAN #23 □ G~ TEST □ GAS PIPING #25 WATER HEATER #28 SOLAR WATER #29 FINAL CODI!!# STORM WATER #600 PRE-CONSTRUCTION MEITING #603 FOLLOW UP INSPECTION #605 NOTICE TO CLEAN #607 WRITTEN WARNING #609 NOTICE OF VIOLATION #610 VERBAL WARNING REV 1012012 Allow 48 hours Call before 2 pm Allow 48 hours Date Inspector #31 □ ELECTRIC UNDERGROUND □ UFER #34 ROUGH ELECTRIC #33 LECTRIC SERVICE O TEMPORARY #35 PHOTO VOLTAIC #39 FINAL UNDERGROUND (11,12,21,31) #82 DRYWALL,EXTtATH, GASTES(17,18,23) #83 ROOFSHEATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) #85 T-Bar (14,24,34,44) ANAL OCCUP.ANCY (19,29,39,49) ~/.S UNDERGROUND VISUAL A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/AFINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS FINAL SEe i3ACK FOR SPECIAL ~OTES 1 Plan ~T ( City of Carlsbad RESIDENTIAL GREEN BUILDING CODE STANDARDS MANDATORY MEASURES CERTIFICATION CHECKLIST Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov B-51 Site Development Mandatory 4.106.2 A plan is developed and implemented to manage storm water drainage during (X ) construction. (X) 4.106.3 The site shall be planned and developed to keep su rface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. Energy Efficiency 4.201 .1 Low-rise residential buildings shall meet or exceed the minimum standard design (X) required by the California Energy Standards. Water Efficiency and Conservation Indoor Water Use 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following (X) methods: 7/01/2011 1. Water saving fixtures or flow restrictors shall be used. 2. A 20 percent reduction in baseline water use shall be demonstrated. (X) 4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads 7/01/2011 shall not exceed maximum flow rates. (X) 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) 7/01/2011 shall comply with specified performance requirements. Outdoor Water Use 4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be (X) weather-based. Enhanced Durability and Reduced Maintenance 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits or other openings in plates at exterior walls shall be protected against the passage of rodents by closing (X) such openings with cement mortar, concrete masonry or similar method acceptable to the enforcinq aqencv. Construction Waste Reduction, Disposal and Recycling 4.408.1 A minimum of 50 percent of the construction waste generated at the site is diverted to (X) recycle of salvage. 4.408.2 Where a local jurisdiction does not have a construction and demolition waste (X) management ordinance, construction waste management plan shall be submitted for approval to the enforcinQ aQency. Building Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the building occupant or (X ) owner. Environmental Quality Fireplaces 4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. ( X ) Woodstoves, pellet stoves and fireplaces shall also comply with aoolicable local ordinances. 8-51 Page 1 of 2 Rev. 04/11 Pollutant Control 4.504.1 Duct openings and other related air distribution component openings shall be covered (X) during construction. 4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound (X) limits. (X) 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. (X ) 4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for ROC and other toxic compounds. (X) 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit finish materials have been used . (X ) 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. 4.504.4 50 percent of floor area receiving resilient flooring shall comply with VOC-emission limits (X) defined in the Collaborative for High Performance Schools (CHPS) Low-emitting Materials List or be certified under the Resilient Floor Covering Institute (RFCI) FloorScore program. (X ) 4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. (X ) 4.505.3 Moisture content of building materials used in wall and floor framing is checked before (X ) enclosure. Indoor Air Quality and Exhaust 4.506.1 Exhaust fans which terminate outside the buildina are orovided in everv bathroom. (X ) Environmental Comfort 4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the (X ) fan is off. Covers or louvers shall have a minimum insulation value of R-4.2. 4.507.2 Duct systems are sized, designed, and equipment is selected using the following methods: (X ) 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent 3. Select heatinq and coolinq equipment accordinq to ACCA 36-S (Manual S) or equivalent. Installer and Special Inspector Qualifications 702.1 HVAC system installers are trained and certified in the proper installation of HVAC ( X ) systems. 702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X ) competence in the discipline thev are insoectina. I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013 California Green Building Standards. Project Address: 2524 Wellspring st Plan Check Number: PC150041 Print Name: C ~/Jl4C-L k..,f2C.<. i Signed: C'~kfl:; License Number: 683543 Date: I O lt:1.I -i., (,,(. ,_ r B-51 Page 2 of2 Rev. 04/11