HomeMy WebLinkAbout2090 WESTWOOD DR; ; CBR2017-0082; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Print Date: 10/03/2017 Residential Permit Permit No: CBR2017-0082 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: II Dwelling Units: Bedrooms: Project Title: 2090 Westwood Dr BLDG-Residential 1671801100 $22,480.67 www.carlsbadca.gov Work Class: Alteration Status: Lot II: Applied: Reference II: Issued: Construction Type: Fina led: Bathrooms: Inspector: Orig. Plan Check II: Plan Check II: Description: HILL: 196 SF KITCHEN REMODEL// 128 SF MASTER BATH REMODEL// 305 SF REAR DECK WITH EXTERIOR STAIRS// PANEL UPGRADE 200A BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) Owner: ED HILL 2090 Westwood Dr Carlsbad, CA 92008-1142 760-402-3264 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 BUILDING STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $518.17 Total Payments To Date: $518.17 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Closed -Finaled 01/12/2017 03/01/2017 AKrog $0.00 $230.27 $154.98 $41.00 $39.00 $49.00 $1.00 $2.92 .... IT,'iE F0LL0WIUG APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING 0 ENGINEERING □BUILDING □FIRE □HEALTH OHAZMATIAPCD ( City of ·Building Permit Application Plan Check No. C£>RW \7-C)Oi 2 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 2l,\7?)- Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date \-12~-\'"":\-ISWPPP www.carlsbadca.gov JOB ADDRESS ZOc/ 0 vvtJ~t?o Pf_ SUITEI/SPACEI/UNrr, IAPN Ii 7 -ltD ll 00 IV,k -- CT;r;;t;~ #/ (L I LOT # z s--IPHAS.r 1 # OF Ur 1 # BEvOMS # BATHROOMS I TENANT BUSIN~...4E I CONSTR. TYPE I occ. GROUP z.r DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) I:: Ill//-f!t.1Y?()J:?tfL -tyy/(.: z z 1/-lQrr /VH7-,1 ,it>n (.)/?/:1_ -f ·1d 6 ~ /ZrJOF; l'-1:},,v Pt(/( -:I~.rQFT- EXISTING USE ~ OPOSED USE 'GARAGE (SF) PATWSF) I 1ir-F) FIREPLACE ' AIR C0N~ITI0 ING 'FIRE SPRINKLERS .fr lt/11.?t~ r ?t:111?/f./t t:_-VI-Pl YEsif NU YES NOD YES□ No0' APPLICANT NAME Ea,v-4 /21?' A--h'/tl. PROPERTY OWNER /J>? /(// /J 1-../1 Primary Contact Jt-7-' ADDRESS z o:/() J,,Jtf r I,,.,(}(>.? ,tJ,,f. ADDRESS CITY C.l/tLf /]~ STATC'"A-ZIP '1 Z{l)f" CITY STATE ZIP PHO~()U '107-12t v r AX PHONE IFAX - EMAIL Eo)I/L.L 70 ~ 6.w7A-/l EMAIL . { Or, DESIGN PROFESSI0NA _} /:{:; ,/Jr'il/U?h/; CONTRACTOR BUS. NAME ./Jr'/l/ (41./7 Jl?-.- ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE rAX PHONE IFAX EMAIL EMAIL I STATE UC.# STATE UC.# I CLASS I CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demohsh or repair any structure. pnor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 or D1v1sion 3 of the Business and Professions Code} or !hat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500}). Workers' Compensation Declaration: I hereby a/f,rm under pena#y of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as reQuired by Section 3700 of Ille Labor Code, for lhe perfo~ce of Ille WOIX for which lhis pemlit is issued. My workers' compensation Insurance carrief and policy number are: Insurance Co. ____________________ Policy No. ______________ Expiration Date ________ _ This section need not be compleled ff lhe permit is for one hundred dolars ($100) or less. 0 Certificate of Exemption: I certify lhat in lhe performance oflhe wolk for which this permit is issued, I shall nolemploy .riy person 111 any manner so as lo become subject to the Workers' ~salion Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attomey's fees. _RS CONTRACTOR SIGNATURE □AGENT DATE • I hereby a/f,rm that I am exempt from Contractors License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do lhe work and the structure is not intended or offered tor sale (Sec. 7044, Business and Professions Code: The Contractors License Law does nol apply lo an owner of property who builds or improves lhereoo, and who does such work himseij or lhrough his own employees, provided that such improvements are nol inlended or offered for ....J. sale. If. however, lhe building or improvement is sold within one year of completion, lhe owner-builder will have lhe burden of proving lhal he did not build or improve for the purpose of sale). -~ I, as owner of the property, am exclusively contracting wilh licensed contractors lo conslrucl lhe projecl (Sec. 7044, Business and Professions Code: The Contraclor's License Law does nol apply lo an owner of property who builds or improves lhereoo, and contracts for such projecls with contractor(s) licensed pursuant lo the Contractor's License Law). □ I am exempt undef Section _____ Business and Professions Code for lhis reason: 1. I personany plan lo provide the major labor and materials for construction of lhe proposed property improvement. D Y es D o 2. I (have I have not) signed an applicalion for a building permit for lhe proposed work. 3. I have contracted with Ille following person (firm} lo provide lhe proposed construction (include name address I phone I conlraclors' license number): 4. I plan lo provide portions of the work, bu! I have hired lhe following person lo coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number) 5. I will provide some of the work, but I have cootracted (hired) the following persons to provide the work indicaled (include name/ address /phone/ type of work): _RS PROPERTY OWNER SIGNATURE~ at.,/~ □AGENT DATE I ;7//6 • Is the applicant 0< future building occupant required to submit a business plan, acutely hazaldous materials registra!ion form 0< nsk management and prevention program under Sections 25505, 25533 0< 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No • Is the applicant 0< future building occupant required lo obtain a penmit frO<n the air pollution control district 0< air quality management district? D Yes D No Is the facility to be constructed within 1,000 feet of the oute< boundary of a school site? D Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUEO UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certifylhatl have read the application and state that the aboYe lnlonmation Is correct and that the lnfonmation on the plans Is aa:urate. I agree to comply with all City ordinances and Slllte laws relating to building construction. I hereby autho!ize representative of the City of Carlsbad to enter upon the above mentioned property for i1spedioo purposes. I ALSO AGREE TO SA VE, INOEM'-llFY AND KEEP HARM..ESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: MOSHA pennit is reqt.ted for excavations <Nef 5'0' deep and demoition oc construction of sb'udures <Nef 3 stories i1 height EXPIRATION: Eve!y permit issued by the Buildilg Official under the provisions of this Code shaD expi'e by imitaticn and become nul and voo f the buikflrlQ oc wcx1( authorized by such pem-it is not coorneoced l'<ithil 180 days frocn the date of such permit0< if the buidilg 0<wcxi( authonzed by such permtt is suspended oc alxmoned at any tine after the wcx1( is coornenced for a period of 180 days (Sedion 106.4.4 Uniform Buildilg Code). ~APPLICANT'SSIGNATURE ~ ~ DATE / /1-z//t STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602.a560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Onlyl CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad CA PHONE FA:x. EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS D PICK UP: o CONTACT (listed above) o OCCUPANT (listed above) o CONTRACTOR (On Pg. 1) □ MAIL TO: o CONTACT (listed above) o OCCUPANT (listed above) o CONTRACTOR (On Pg. 1) D MAIL/ FAX TO OTHER: ________________ _ A$ APPLICANT'S SIGNATURE o ASSOCIATED CB#------------- 0 NO CHANGE IN USE/ NO CONSTRUCTION o CHANGE OF USE / NO CONSTRUCTION DATE ZIP Permit Type: BLDG-Residential Application Date: 01/12/2017 Owner: ED HILL Work Class: Alteration Issue Date: 03/01/2017 Subdivision: Status: Closed -Finaled Expiration Date: 03/13/2018 Address: 2090 Westwood Dr Carlsbad, CA 92008-1142 IVR Number: 1413 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 06129/2017 06/2912017 BLDG-18 Exterior 027598-2017 Passed Jonathan West Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/13/2017 07/13/2017 BLDG-21 028586-2017 Passed Andy Krogh Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Water from meter to house Yes 0813012017 08/30/2017 BLDG-Final 033143-2017 Failed Andy Krogh Relnspectlon Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, pre final walk No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 09/14/2017 09/1 4/2017 BLDG-14 034623-2017 Partial Pass Andy Krogh Reinspection Incomplete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Enclose bottom of rail so space is less than No 4" BLDG-Final 034784-2017 Partial Pass Andy Krogh Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Complete forms and install final sink, No correct bottom of guardrail, ok to occupy BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes 10/03/2017 10/03/2017 BLDG-Final 036514-2017 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes October 03, 2017 Page 2 of 2 Permit Typo: BLDG-Residential Application Date: 01/12/2017 Owner: Work Class: Alteration Issue Date: 03/01/2017 Subdivision: Status: Closed -Finaled Expiration Date: 03/13/2018 Address: Scheduled Date 03/20/2017 Actual Start Date 03/20/2017 03/30/2017 03/30/2017 04/12/2017 04/12/2017 05/31/2017 05/31/2017 06/02/2017 06/02/2017 06/09/2017 06/09/2017 06/23/2017 06/23/2017 October 03, 2017 IVR Number: 1413 Inspection Type BLOG-22 Sewer/Water Service Inspection No. 017023-2017 Checklist ltom BLDG-Building Deficiency BLDG-11 Foundation/Fig/Pier s (Rebar) 018178-2017 Checklist Item BLDG-Building Deficiency BLDG-13 Shear Panels/HD (ok to wrap) BLOG-84 Rough Combo(14,24,34,44) 019835-2017 024944-2017 Checklist Item BLDG-Building Deficiency BLOG-14 Frame-Steel-Bolting-Welding (Decks) BLOG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLOG-84 Rough Combo(14,24,34,44) 025097-2017 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-17 Interior Lath/Drywall 025748-2017 Checklist Item BLDG-Building Deficiency BLDG-33 Service Change/Upgrade 027006-2017 Checklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Passed Andy Krogh COMMENTS From bottom plate line to sewer connection Passed Andy Krogh COMMENTS Columns footings, interior footing, and extenor steel for misc flat work Passed Andy Krogh Failed Andy Krogh COMMENTS Draftstop chase between floors Add mst 30 , cts218 in 5 locations Up stairs halfway outlet, move smokes for clearance Passed Andy Krogh COMMENTS Draftstop chase between floors Interior stairs to be completed Passed Paul Burnette COMMENTS Passed Paul Burnette COMMENTS ED HILL 2090 Westwood Dr Carlsbad, CA 92008-1142 Reinspection Complete Complete Passed Yes Complete Passed Yes Complete Reinspection Complete Passed No No Yes No Yes Complete Passed No No Yes Yes Yes Complete Passed Yes Complete Passed Yes Page 1 of 2 DAN HUFF INSPECTIONS 2064 Meadowlark Ranch Circle (858) 583-3959 San Marcos, CA 92078 I JOB NO. 'DATE I I '61 7 CERTIFIED INSPECTOR'S DAILY REPORT .. - COVERING WORK PERFORMED 0 REINFORCED CONCRETE 0 STRUCT STEEL ASSEMBLY O SPRAY-APPLIED FIREPROOFING WHICH REQUIRED APPROVAL BY 0 PRE-STRESSED CONCRETE 0 EPOXY 0 OTHER THE SPECIAL INSPECTOR OF 0 REINFORCED MASONRY 0 WOOD FRAME JOBAOORESS ~j {)1 __ ~---·" BUILDING~ NUMB£, ( ",,). l·t. rLAN FILl:NUMBER ~EA OIi PROJECT NAME I) -, ARCHITECT -' I ,. ' j c... CONSTR. MAlL (TYPE. GAADE. ETQ IDESIGN SOURCE Of MFGII ENGINEER -~ --STRENGTH • -OESCIUBE MATL (MIX DESIGN, RE-BAA GAAOE & MFGR, WELD-ROD, ETQ GENERAi. CONTAACTOR -I IE v11.. 011 fl ' fJ/ll.ll 1-CONTI\. DOING REf>ORlIO WORK I J I -I •-• LI- /'. I LAB. RECEIVING & TESTING CONSTR. MATL SAMPLES I ~ INSPECTl()fj OETAILID REPORT DATE Of WORK INSPECTED LOCAnONOf-~ TUTSAMPUSTAIWl,-IIUICTU),JOe-EMS,l'IIDGMSS,IIIEMAlll(J.fTC IMCWDES ~ AIOOr • ~Of ... 1£AIAl.l'tACU>OIIWON<--()IIM(nNUMlfA, lY1'UIOCNT. NO'S Of TEST SAMPIB lAl([H, STAUCT CDIMCTIONS !WU.OS MACE. H. l. lOlJS TORQU£D) CH(O(IO; £TC . ? l ". Jl lJ > _ rrc /~, I~ . . --I. - 9''o-C_ / . -_ _!' -I., -,.., :::t: ;V C. ,. _ /' I') u -l ). _.., --. r ,A.. .,_.) -rJ ~ .. ' ... l.,1_ . . A_,,..,,/J )NJ . , 'J J,.JA /JR. ALL ,. ; -' -/_ ..OM'! ~/_,{"ff /J !. ·-/£ ' ) i _!) .. 'I,/ /20/) \, > r, --.., . • / J L //A10 ).,..I rul.l C/c-M /'/< -'~oo .JLI -/2..,/Ld c//< /2-t117 /r // / -~'f"lt'"'l\l-n ■,------~ JUN O 2 2017 r.lTY ()I= r.ARI ~a An , BUILDING DIVI :,ION .,,. ' -J ----INSPECTOR (PRINT OR TYPE) 1,v /YV/'I~ SIGNATURE: /~ DATE SIGNED: I I CERTIFICATE NO. -:-., 41-,/A(.,,-/. 7_ '/. .... . CERTIFICATION Of COMPLIANCE: to the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plans. specifications and appllcable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering pin Ion or project control. Structural Inspections -• A Special Inspection Company• P.O. Box 2415, El Cajon, CA 92021 Telephone: (619) 749-4912, Fax: (619) 669-6709, Cell: (619) 770-9559 Inspection Report Project Name: HILL RES ------------------Page: 1 of 1 Report#: 01 Project Address: 2090 WESTWOOD DR. Architect: Permit#: CBR20170082 File#: ---- ------------------Engineer: ------------D SA#: ------------------Contractor: ------------0th er: ,QTY D Structural Steel D H.S. Bolts -----1 D H.S. Bolts --------1 [8J Plans/Specs D Masonry D Prisms -----1 D Cone. PSI --------l D Clearances D Concrete D Mortar/Grout ----< D Grout PSI --------1 D Positions D Fireproofing D Cone. Cylinders ----, D Mortar PSI --------l [8J Sizes D Other: D Fireproof ---...., [8J Steel 5/8", 7/8", # 5 D Laps [8J Other: EPOXY D Other: -----1 D Elect.M'ire --------l O Consolidation D Other: • D Other: ----i O Fireproof --------l D Torque Ft.Lbs: D Other: D Other: -----1 0 Other: _______ 0 Other: D Other: 0 Other: D Other: D Other: SPECIAL INSPECTION ON THE INSTALLATION OF THE FOLLOWING EPOXY ITEMS: 1. 2 TOTAL, 7/8" H8 H.D. BOLTS, 16" EMBED. LINE 1. 2. 1 TOTAL, 5/8" HDU2 H.D. BOLT, 11" EMBED. LINE 1. 3: 5/8" ANCHOR BOLTS AT NEW P25 SHEAR PANEL. LINE 1. 4. # 5 REBAR DOWELS AT NEW FOOTING TIES. 8A I S3. 18" EMBED. 5. # 4 REBAR DOWELS AT INTERIOR FOOTING. 6" EMBED 9 / S4. VERIFIED BOLT, BAR TYPES, SIZES, HOLE SIZES, DEPTH, LOCATION, CLEANLINESS AND EPOXY TYPE PRIOR TO INSTALL. CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. ~•GJ,2 Inspector: MARIO BA TT AGLIA Cert: City of SD #350 '__ L _ 3/28/17 Signature Date ......................................... , ................ , ............................................ , ....... , ................................................................................ y .. , ............................................................................................................. , ........................................... "l Ins • Date: .......................... l..,Day 1: ........................................... ) .. Day 2: ............................................... L.,Day 3: ................................. L,Day 4: ......................................... L,Day.5: ...................... j Time Start: i 11:00 i ! i ! i .. Time .. Stop: ............................. i ........ 1.:00 ............................................... i .................................................................. i .................................................... ! ............................................................ J ........................................... j Coples of report submitted to: RECEIVED JUN O 2 2017 CITY OF CARLS:3AD E:UIL0!NG Di\/, :;ION EsGil Corporation In <Partnersfiip witfi <}ot1ernment for <Buifaing Safety DATE: Feb 20, 2017 JURISDICTION: Carlsbad PLAN CHECK NO.: R2017-0082 PROJECT ADDRESS: 2090 Westwood Dr SET: III D APPLICANT -d"JURIS. D PLAN REVIEWER D FILE PROJECT NAME: Interior Remodel for SFD & Deck Addition to Hill Residence l:8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: l:8J EsGil Corporation staff did not advise the applicant that the plan check has been completed . D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted . Edward A. Hill Date contacted. (b~ Telephone#: Email: Mail Telephone Fax In Person 0 REMARKS: By: Rich Moreno for A.D. Enclosures: EsGil Corporation 0 GA O EJ O MB O PC Feb 16, 2017 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1 576 EsGil Corporation In <Partnersliip witli qovernment f or (]Jui(ifin9 Safety DATE: February 14, 2017 JURISDICTION: Carlsbad PLAN CHECK NO.: R2017-0082 PROJECT ADDRESS: 2090 Westwood Dr SET: II V PPLICANT ~:URIS. • D PLAN REVI EWER D FILE PROJECT NAME: Interior Remodel for SFD & Deck Addition to Hill Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. i:gJ The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. l:g] The applicant's copy of the check list has been sent to: Edward A. Hill D EsGil Corporation staff did not advise the applicant that the plan check has been completed. l:g] EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted : Edward A. Hill Telephone#: 760-402-3264 ._2ete coi;acted: ~ { 4-(by()L.) 1:_;Mail /Telephone,. r Fax In Person 0 REMARKS: By: Abe Doliente EsGil Corporation 0 GA O EJ O MB O PC Email: edhill70@gmail.com Enclosures: 2/9/17 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad R2017-0082 February 14, 2017 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code).Signatures will be verified before the plans are approved. FRAMING 11 a. Show FB-4 (double 2 X 10) as called out on pages 4 and 11 of the structural calculations. Refer to sheet S-5 of the plans. 11 b. Show P-1 and P-2 (both 4 X 4) as called out on pages 4, 23 & 24 of the structural calculations. Refer to sheet S-5 of the plans. 11c. Special inspection is required for shear walls with nail spacing less than 4" Use the attached special inspection form from the city. 20. Sheet S-5 of the plans refers the stairs detail to 20A/S-4. This should be referred to 20A/s-3. Revised sheet S-5 was not changed. Carlsbad R201 7-0082 February 14, 2017 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. EsGil Corporation In <Partnersliip witli (jovernment for <Bui{ain9 Safety DATE: January 26, 2017 JURISDICTION: Carlsbad PLAN CHECK NO.: R2017-0082 PROJECT ADDRESS: 2090 Westwood Dr SET: I ~PPLICANT /"' JURIS. □ PLAN REVIEWER □ FILE PROJECT NAME: Interior Remodel for SFD & Deck Addition to Hill Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Edward A. Hill D EsGil Corporation staff did not advise the applicant that the plan check has been completed . ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted : Edward A. Hill Telephone#: 760-402-3264 ~ate coptacted: \ J'l lO (by: Yb.--, Email: edhill@gmail.com €>,ail V {j le~n~ Fax In Person □ REMARKS: By: Abe Doliente EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 1/17/17 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fornia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad R2017-0082 January 26, 2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: R2017-0082 JURISDICTION: Carlsbad PROJECT ADDRESS: 2090 Westwood Dr FLOOR AREA: Int. Rem odel -352 SF STORIES: 2 Deck Addn -305 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: January 26, 2017 FOREWORD (PLEASE READ): HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/17/17 PLAN REVIEWER: Abe Doliente This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a build ing permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC , 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad R201 7-0082 January 26, 2017 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code). 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2016 California Residential Code, which adopts the 2015 IRC, 2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1. • FIRE PROTECTION 3. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 4. Please check the location of the smoke alarm inside the master bedroom. The smoke alarm must be at least 3 feet away from the tip of the blade of a ceiling mounted fan . • GENERAL RESIDENTIAL REQUIREMENTS 5. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. Doors N5, NB and N10 must comply. b) Glazing in the walls/doors facing or containing bathtubs and showers where the bottom exposed edge of the glazing is less than 60" above the standing surface. Window N7 must comply. Carlsbad R201 7-0082 January 26, 2017 • EXITS, STAIRWAYS, AND RAILINGS 6. Guards (Section R312): a) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". b) Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301 .5. 7. Provide stairway and landing details. Section R311 .7. a) Maximum rise is 7-3/4" and minimum run is 10", measured from the nosing projection. Where there is no nosing, the minimum run is 11 ". b) The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. 8. Open risers are only permitted if the opening between treads does not permit the passage of a 4" diameter sphere. Section R311.7.5.1. 9. A nosing (between ¾" and 1-¼") shall be provided on stairways with solid risers. Exception: No nosing is required if the tread depth is at least 11 inches. Section R311.7.5.3. 10. Handrails (Section R311.7.8): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. b) The handgrip portion of all handrails shall be not less than 1-¼ inches nor more than 2 inches in cross-sectional dimension. See Section R311 .7.8.3 for alternatives. c) Handrails projecting from walls shall have at least 1-½ inches between the wall and the handrail. d) Ends of handrails shall be returned or shall have rounded terminations or bends. • FRAMING 11 . Provide supporting structural design calculations to show how you arrived at the proposed shear walls and HD's on sheets-4 and S-5 of the plans. Include the lateral support of the deck. • ELECTRICAL 12. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. Carlsbad R201 7-0082 January 26, 2017 13. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.?0(A). 14. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i .e., all receptacles in a dwelling). b) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living , bedrooms, dining, halls, etc. • PLUMBING 15. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. • ENERGY CONSERVATION 16. Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2016 Energy Efficiency Standards is necessary for this project. Registered , signed , and dated copies of the appropriate CF1 R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." 17. When replacing or modifying the mechanical system : o If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. o Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, It is not required at initial plan submittal. • MISCELLANEOUS 18. Revise sheet A-2 of the plans to show the new deck and the new stairs at the west side on the second floor plan. Carlsbad R201 7-0082 January 26, 2017 19. Sheet S-4 of the plans shows 8 X 8 post for the support column for the stairs, but sheet A-2 of the plans shows 6 X 6. Please revise sheet A-2 to agree with the structural plans. 20. Sheet S-5 of the plans refers the stairs detail to 20A/S-4. This should be referred to 20A/s-3. 21 . To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 22. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 23. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. Carlsbad R201 7-0082 January 26, 2017 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Abe Doliente BUILDING ADDRESS: 2090 Westwood Dr BUILDING OCCUPANCY: R3/U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Interior Remodel 352 45.78 Deck Addn 305 19.71 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance 3 Plan Check Fee by Ordinance ..-1 Type of Review: Complete Review D Repetitive Fee "'3 Repeats Comments: D Other D Hourly EsGil Fee PLAN CHECK NO.: R2017-0082 DATE: January 26, 2017 Reg. VALUE ($) Mod. 16,115 6,012 22,126 $229.901 $149.441 D Structural Only $128.741 Sheet 1 of 1 macvalue.doc + soGf connected A ~ Sempra Energy ut<111y· ELECTRIC OVERHEAD METER & SERVICE LOCATION Customer Copy Notification #: 300000154399 Job #: 530000084815 I TB: 1087-H7 Wanted Date: ON INSPECTION Date Prepared: 06/12/2017 Customer Type: Residential(1-2 Units) Service Type: OH SERVICE REWIRE REATTACH AT W/H Project Title: SOLAR -TROUPE, NEIL (SOD Project Address: 2090 WESTWOOD DR I Project City: CARLSBAD Additional Address Info: Customer POC: BRYAN WILSON Customer Phone #: 442-237-3392 SDGE Contact: Service Coordinator Contact Info: TIM SHERLOCK, 760-476-5619 l JTraffic Control Permit Required l JSDG&E Application Required-Call: 1-800-411 -7343 Excavation/Encroachment Permits Required By: Municipal Inspection Required By: CITY OF CARLSBAD I Temp Service Charge due on First Bill $ 0.00 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Locate the new point of attachment within 18 inches of the northeast corner on the north wall. Install rigid riser minimum of 2 feet above roof and meet minimum clearances as noted below. Locate new 200 amp meter panel 36" AWAY FROM SDG&E RISER location on the north wall RIGHT OF THE RISER as indicated on sketch. Customer to provide and maintain 3 foot by 3 foot clear and level workspace in front of electric panel. Customer is advised to install overhead/underground combo panel for possible future underground conversion. City inspection and approval are required prior to service reconnection. Provide Minimum Ground Clearance Of: _ 1 0_ Ft. From bottom of drip loop at service wire point of attachment _ 12_ Ft. Over driveway or parking area -16_ Ft. At outer limit of vehicular traffic _2_ Ft. Minimum rigid riser above roof -18_ Ft. CENTER LINE OF ST. Service Panel Rating: 200 Number/Size of Main Switch: I Voltage: 120/240 # of Wires: 3 I Phase: 1 Utilities Maximum Contribution to Fault Current: 10000 Metering: Self-Contained I Meter Clips: 4 Meter height -4'0" min. (3'0" min. for multiple installation) -6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition. Provide 3-ft. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number it serves. Additional Information: □Right of Way Required Assessor's Parcel Number: City/County inspection should be received prior to 2:00 p.m. on the same day as the disconnection of service to allow the SDG&E crew enough time for reconnection of the service on the same day. If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and ii will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of construction unless it is through negligence of SDG&E. Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is void after six (6) months. Keep this notice with building permit. All installations performed under this order must meet SDG&E standards unless a written deviation has been aooroved. Planned By: Steven Ossey Phone#: 7604765612