HomeMy WebLinkAboutCDP 2025-0004; FORREST RESIDENCE TAMARACK AVENUE; GEOTECHNICAL SOILS REPORT; 2022-09-13EAST COUNTY SOIL CONSULTATION
AND ENGINEERING, INC.
10925 HARTLEY ROAD, SUITE "I"
SANTEE, CALIFORNIA 92071
TEL. 619-258-7901
Robert & Lillian Appleby
23 918 Ingomar Street
West Hills, California 91304
Subject: Geotechnical Investigation for Proposed, Two-Story,
Single-Family Residence
1644 Tamarack Avenue
Carlsbad, California 92008
Dear Mr. & Mrs. Appleby:
September 13, 2022
Project No. 22-1106G6
In accordance with your request, we have performed a geotechnical investigation at the subject site
to determine the geotechnical site conditions and provide recommendations for design and
construction of the proposed two-story, single-family residence.
SCOPE OF SERVICES
The following scope of work was performed for this investigation:
0 Site reconnaissance and review of published geologic and geotechnical reports and maps
pertinent to the project area.
0 Subsurface exploration consisting of excavating two test pits within the general area of the
proposed construction. The test pits were logged by our project supervisor.
0 Collection of representative soil samples at selected depths. The obtained samples were stored
in moisture-resistant containers and transported to our soil testing laboratory for subsequent
analysis.
0 Laboratory testing of soil samples obtained during the subsurface exploration.
0 Geotechnical analysis of the field and laboratory data, which provided the basis for our
conclusions and recommendations.
0 Preparation of this report, which summarizes the results of our analysis and presents our
findings and recummem.lation:s fu1 L11t:: prupu:st::d cun:strucliun.
Geotechnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
SITE DESCRIPTION AND PROPOSED CONSTRUCTION
Pagel
September 13, 2022
Project No. 22-1106G6
The site location is shown on the attached Vicinity Map, Figure 1. The site consists of a
rectangular-shaped, residential lot located on the north side of Tamarack Avenue in Carlsbad,
California (see Figure 2). The lot is presently vacant and slopes gently down to the south. The lot
is bordered by Tamarack Avenue to the south and other homes to the west, east and north. Site
vegetation consists of ice plants, shrubs and a few trees.
The proposed construction consists of a two-story, single~family residence. The building will be
wood-framed and supported on continuous and/or individual spread footings with a slab-on-grade
floor.
SUBSURFACE EXPLORATION AND LABORATORY TESTING
The subsurface exploration was performed on August 16, 2022 and consisted of excavating two
test pits to a maximum depth of 8 feet with a mini-excavator. The approximate locations of the test
pits are shown on Figure 2. Logs of the test pits are presented on Figure 3.
Following the subsurface exploration, laboratory testing was performed on representative soil
samples to evaluate the pertinent engineering properties of the foundation materials. The
laboratory tests included moisture content, dry density, maximum density and optimum moisture
content, sieve analysis and an expansion index test. The tests were performed in accordance with
ASTM standards. The test results are shown on the Logs of the Test Borings, Figure 3 and on
Figure 4, Results of Laboratory Tests.
SUBSURFACE SOIL CONDITIONS
The subsurface soil descriptions were interpreted from conditions encountered during the subsurface
exploration and/or inferred from the geologic literature. Detailed descriptions of the subsurface soils
are presented on the logs of the test pits presented on Figure 3. The following is a generalized
description of the soils.
Fill: Fill was encountered in the test pits with a thickness of 4 to 5 feet and consisted of light to dark
reddish brown, silty sand that was dry, loose to medium dense in the upper 2 feet; below that the fill
was medium dense to dense.
Slopewash: Slopewash was encountered in test pit T-2 below the fill with a thickness of 2 feet. The
slopewash consisted of dark reddish brown, moist, medium dense, silty sand.
Terrace Deposits: Terrace deposits were encountered beneath the fill and slopewash to the
maximum depth explored of 8 feet. The terrace deposits consisted of reddish brown, dry to moist,
medium dense to dense, silty sand.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
GeotechnicaJ Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
SOIL PROPERTIES
a. Compressible Soils
Page3
September 13, 2022
Project No. 22-1106G6
Our field observations and testing indicate that loose to medium dense fill soils exist to a depth of
about 2 feet below existing grades.
b. Expansive Soils
An expansion index test (ASTM D 4829) was performed on a representative sample of the fill
soils. The results of the test are shown on Figure 4. An expansion index of O was obtained which
indicates the fill soils are very low expansive.
c. Groundwater
Static groundwater was not encountered to the depths of the test pits. The proposed building is
located at an elevation over 150 feet above Mean Sea Level. We do not expect groundwater to
affect the proposed construction. Recommendations to prevent or mitigate the effects of poor
surface drainage are presented in the Drainage section of this report.
GEOLOGY
From published geologic maps, the site is underlain at depth by sedimentary terrace deposits. There
are no known geologic hazards such as landslides, liquefaction-prone areas, or earthquake faults at
the site. However, the proposed building is subject to ground shaking and possible damage from
earthquakes on nearby, or more distant, active faults.
SEISMIC DESIGN VALUES
Seismic design values are presented on Figure 5.
CONCLUSIONS
Construction of the proposed single-family residence is feasible from a geotechnical standpoint,
provided the recommendations presented in this report are properly implemented during construction.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
RECOMMEND A TIO NS
SITE GRADING
a. Site Clearing
Page4
September 13, 2022
Pro.iect No. 22-1106G6
The area of the new building should be cleared of vegetation, concrete fragments and debris,
surface and subsurface obstructions and other deleterious materials. These materials should be
properly disposed of off-site.
b. Temporary Slopes and Excavations
Temporary vertical slopes and excavations should not exceed 5 feet in height. Temporary slopes and
excavations greater than 5 feet in height should be shored or laid back at a maximum inclination of 1 : 1
(horizontal to vertical).
c. Surface Soil Removals
Within the new building area and to a distance of at least 5 feet outside building limits, the fill soils
should be removed to a minimum depth of 2 feet, and replaced with properly compacted fill. Actual
removal depths should be confirmed during grading by our field representative.
d. Compaction and Method of Filling
Prior to fill placement, the exposed subgrade soils should be scarified to a depth of 6 to 8 inches,
moisture-conditioned slightly above the optimum moisture content and compacted to at least 90
percent relative compaction.
The on-site soils may be reused as compacted fill, provided they are free of organic materials and
debris, and rocks or cobbles over 6 inches in dimension. Any imported fill soils should be
predominantly granular and very low expansive (EI less than 20) and approved by our field
representative.
All fill should be compacted to a minimum relative compaction of 90 percent as determined by
ASTM D1557. Fill should be placed at a moisture content slightly above the optimum moisture
content, in lifts 6 to 8 inches thick, with each lift compacted by mechanical means.
Utility trench backfill and retaining wall backfill should also be compacted to at least 90 percent
relative compaction.
All grading, fill placement, and compaction should be performed in accordance with the grading
requirements of the City of Carlsbad. Fill placement and compaction should be observed and
tested as necessary by our field representative.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotecbnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
EROSION CONTROL
Page5
September 13, 2022
Project No. 22-1106G6
Due to the predominantly sandy nature of the on-site soils, areas of recent grading or exposed ground
may be subject to erosion. During construction, surface water should be controlled via benns,
gravel/sandbags, silt fences, straw wattles, siltation or bioretention basins, positive smface grades or
other method to avoid damage to the finish work or adjoining properties. All site entrances and exits
must have coarse gravel or steel shaker plates to minimize offsite sediment tracking. Best
Management Practices (BMPs) must be used to protect storm drains and minimize pollution. The
contractor should take measures to prevent erosion of graded areas until such time as pennanent
drainage and erosion control measures have been installed. After completion of grading, all excavated
surfaces should exhibit positive drainage and areas where water might pond should be eliminated.
FOUNDATIONS AND FLOOR SLABS
• Continuous and/or individual footings should be founded in properly compacted fill at a
minimum depth of 18 inches below building pad grade or lowest adjacent finished grade,
whichever is deeper.
• Continuous footings should be at least 15 inches wide and reinforced with a minimum of four
#4 steel bars, with two bars placed near the top of the footings and the other two bars placed
near the bottom of the footings. Individual footings should be at least 18 inches square and
reinforced with a grid of #4 bars spaced 12 inches on centers ( each way) and placed on concrete
blocks at the bottom of the footing.
• An allowable soil bearing value of 2,000 pounds per square foot may be used for the design of
continuous and spread footings at least 12 inches wide and founded a minimum of 12 inches
into properly compacted fill soils as set forth in the 2019 California Building Code. This value
may be increased by 400 psf for each additional foot of depth or width to a maximum value of
4,000 psf.
• Lateral loads may be resisted by an equivalent fluid passive soil pressure of 350 pounds per
cubic foot. A coefficient of friction of 0.35 may also be used. If passive and friction values are
used together, the passive value should be reduced by one-third.
• All footing excavations should be observed and approved by our field representative. Footing
excavations should be thoroughly cleaned prior to concrete pour.
• For design purposes, total and differential settlements of½ inch and¼ inch respectively may be
assumed.
• Floor slabs, including garage slabs, should be at least 5 inches thick and reinforced with #4 bars
placed at 18 inches on centers in two directions in the middle of the slabs. The reinforcing steel
should be supported on steel chairs or concrete blocks. Floor slabs should be underlain by 2
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for ProJ)osed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
Page6
September 13, 2022
Project No. 22-1106G6
inches of clean sand over a 10-mil visqueen moisture barrier over 2 inches of clean sand. To
minimize the potential for shrinkage cracks, concrete should have a minimum compressive
strength of 3,000 psi and maximum water-cement ratio of0.5. No special inspection of concrete
is required. Some shrinkage cracks are still possible.
SURFACE DRAINAGE
Surface water should not be allowed to pond next to buildings. Finished grades should slope at
least 2 percent away from buildings and along drainage swales. Roof gutters and downspouts
connecting to solid, outlet pipes are recommended. Outlet pipes should be discharged to an
approved outlet.
LIMITATIONS OF INVESTIGATION
Our investigation was performed using the skill and degree of care ordinarily exercised under similar
circumstances by reputable soil engineers and geologists practicing in this or similar localities. No
other warranty, expressed or implied, is made as to the conclusions and professional advice included in
this report. This report provides no warranty, either expressed or implied, concerning future building
performance. Future damage from geotechnical or other causes is a possibility.
This report is prepared for the sole use of our client and may not be assigned to others without the
written consent of the client and ECSC&E, Inc.
The samples collected and used for testing, and the observations made, are believed representative of
site conditions; however, soil and geologic conditions can vary significantly between exploration
trenches, test borings and surface exposures. As in most major projects, conditions revealed by
construction excavations may vary with preliminary findings. If this occurs, the changed conditions
must be evaluated by a representative of ECSC&E and designs adjusted as required or alternate
designs recommended.
This report is issued with the understanding that it is the responsibility of the owner, or of his/her
representative to ensure that the information and recommendations contained herein are brought to the
attention of the project architect and engineer. Appropriate recommendations should be incorporated
into the structural plans. The necessary steps should be taken to see that the contractor and
subcontractors carry out such recommendations in the field.
The findings of this report are valid as of this present date. However, changes in the conditions of
a property can occur with the passage of time, whether they are due to natural processes or the
works of man on this or adjacent properties. In addition, changes in applicable or appropriate
standards may occur from legislation or the broadening of knowledge. Accordingly, the findings of
this report may be invalidated wholly or partially by changes outside of our control. Therefore, thls
report is subject to review and should be updated after a period of two years.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Pro11osed, Two-Story, Single-Family Residence
1644 Tamarack A venue
Carlsbad, CA 92008
DEPTH
FIGUREJ
LOGS OF TEST PITS
TEST PIT T-1
SOIL DESCRIPTION
Surface FILL
0.5'
1.5'
2.0'
2.5'
3.5'
4.0'
5.0'
reddish brown, dry, loose to medium dense, silty sand
II ti II II II It
" " II II II II
dark reddish brown, dry, medium dense to dense, silty sand
" II
" " II
TERRACE DEPOSITS
"
II
II
"
II
II
II
reddish brown, dry to moist, medium dense to dense, silty sand
bottom of test pit, no caving, no grow,dwater
test pit excavated and backfilled 8/16/2022
Page 10
September 13, 2022
Project No. 22-1106G6
y M
116.2 2.6
111.8 4.7
124.7 4.9
126.5 4.6
----------------------------------------------------------------------------------------------------------------------------------
TEST PIT T-2
DEPTH SOIL DESCRJPTION
Surface FILL
1.5'
2.0'
5.0'
6.0'
7.0'
8.0'
reddish brown, dry, loose to medium dense, silty sand
tt ti n ft tt If ft
dark reddish brown, dry, medium dense to dense, silty sand
SLOPEWASH
dark reddish brown, moist, medium dense, silty sand
It tt tt tt ti It "
TERRACE DEPOSITS
reddish brown, dry to moist, medium dense to dense, silty sand
bottom of test pit, no caving, no groundwater
test pit excavated and backfilled 8/16/2022
Y = DRY DENSITY IN PCF
M = MOISTURE CONTENT IN %
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
y M
111.8 6.4
121.7 10.0
Geotechnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Page 11
September 13, 2022
Project No. 22-1106G6 Carlsbad, CA 92008
TEST
LOCATION
T-1 @ 2.0'
TEST
LOCATION
T-1 @ 2.0'
FIGURE4
RESULTS OF LABORATORY TESTS
INITIAL
MOISTURE
CONTENT
(%)
9.1
SOIL TYPE/
EXPANSION INDEX TEST
(ASTM D 4829)
SATURATED INITIAL
MOISTURE DRY
CONTENT(%) DENSITY
(PCF)
18.0 112 .2
MAXIMUM DENSITY TEST
(ASTM D 1557)
SOIL
PROCEDURE DESCRIPTION
1
U.S. Standard
Sieve Size
2"
I"
1/2"
3/8"
#4
#8
#16
#30
#50
#IO0
#200
uses
FILL: REDDISH BROWN,
Sll.,TYSAND
PARTICLE SIZE ANALYSIS
(ASTMD422)
EXPANSION
INDEX
0
MAXIMUM
DRY DENSITY
(PCF)
129.0
Percent Passing
T-1 @2.0'
Fill
---
100
99
99
98
89
53
23
18
SM
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
EXPANSION
POTENTIAL
VERY LOW
OPTIMUM
MOISTURE
CONTENT(%)
9.0
Geotechnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Page 12
September 13, 2022
Project No. 22-1106G6 Carlsbad, CA 92008
FIGURES
SEISMIC DESIGN VALUES
1644 Tamarack Ave, Carlsbad, CA 92008, USA
Lat1tud , , , ,r
Date
Design Code Reference Document
Risk Category
Sit• Class
Type Value
Ss 1.033
51 0.375
SMs 1.122
SM: null -See Section 11.4.8
Sos 0.748
So: null -See Section 11.4.8
Type Value
SDC null -See Section 11.4.8
Fa 1.087
Fv null -See Section 11.4.8
Description
Description
8/29/2022, 200:56 PM
ASCE7-16
Ii
D -Sti' Soil
MCEi, ground motion. (for 0.2 second period)
MCE;;, ground motion. (for 1.0s period)
Site-modified spectral acceleration value
Site-modifed spectral acceleration value
umer'c seismic design value at 0.2 second SA
Numeric seismic design value at 1.0 second SA
Seismic design category
Site amplification factor at 0.2 second
Site ampli ication factor at 1.0 second
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotecbnical Investigation for Proposed, Two-Story, Single-Family Residence
1644 Tamarack Avenue
Carlsbad, CA 92008
REFERENCES
Page 13
September 13, 2022
Project No. 22-1106G6
1. "2019 California Building Code, California Code of Regulations, Title 24, Part 2, Volume 2
of 2", Published by International Code Council.
2. "Geologic Map of the San Diego 30' x 60' Quadrangle, California", by Michael P.
Kennedy and Siang S. Tan, 2008.
3. "Geotechnical and Foundation Engineering: Design and Construction", by Robert W. Day,
1999.
4. "Maps of Known Active Fault Near-Source Zones in California and Adjacent Portions of
Nevada to be used with 1997 Uniform Building Code", Published by International
Conference of Building Officials.
5. "Geologic Maps of the Northwestern Part of San Diego County, California", Department of
Conservation, Division of Mines and Geology, by Siang S. Tan and Michael P. Kennedy,
1996.
6. "Bearing Capacity of Soils, Technical Engineering and Design Guides as Adapted from the
US Anny Corps of Engineers, No. 7", Published by ASCE Press, 1994.
7. "Foundations and Earth Structures, Design Manual 7.2", by Department of Navy Naval
Facilities Engineering Command, May 1982, Revalidated by Change 1 September 1986.
8. "Ground Motions and Soil Liquefaction during Earthquakes", by H.B. Seed and I.M. Idriss,
1982.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.