HomeMy WebLinkAboutMCUP 08-22; SPRINT SD36XC281 GRAND PACIFIC; RADIO FREQUENCY ELECTROMAGNETIC FIELDS EXPOSURE REPORT; 2008-12-29(.0\1MI ~ICAflO'.S, 11 (
11526 Sorrento Valley Road, Ste. F
San Diego, CA 92121
Phone/Fax: 866.988.0066
www.dtechco111.com
RADIO FREQUENCY ELECTROMAGNETIC FIELDS EXPOSURE REPORT
Prepared For
Sprint'>. ToptllorwllhNEXTtl
Site: CA6998_SD36XC281, Pacific Grand Palisades
Located at:
5805 Armada Drive
Carlsbad, CA 92008
Latitude: 33.1239 / Longitude: -117.3152
12/29/2008
------------------
Page 1/13
EXECUTIVE SUMMARY
Dtech Communications, LLC ("Dtech") has been retained by Sprint Nextel to determine
whether their communication facility complies with the Federal Communications
Commission ("FCC") Radio Frequency ("RF") Safety Guidelines. This report contains an
on-site, measurement analysis of the Electromagnetic Fields ("EMF") exposure resulting
from the cell site. The table below summarizes the result at a glance.
Site ID/Num
Access to Antennas Locked
RF Si n s) @Access Points)
RF Si n s /Barriers @Antennas
Max El\iF Level on roof, near
S rint Nextel Antennas
Max EMF Level on Ground
FCC Com liance Status
Table 1: EMF Summary
C.:\6998_SD36X C28 l
Yes
Notice
Notice
15.2%OC (76.0% GP)
0.45%GP
Yes ----------------~-----
BACKGROUND
The engineering staff at Dtech does not establish the guidelines used to ensure safety
exposure levels emitted from RF electromagnetic fields associated with wireless
communication, radio and television equipment. Dtech. uses the FCC's guidelines described
in detail in Office of Engineering & Technology, Bulletin No. 65 ("OET-65") "Evaluating
Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic
Radiation". Table 2 below summarizes the current Maximum Permissible Exposure
("MPE") safety limits classified into two groups: General population and Occupational.
11526 Sorrento Vaflry Road, Ste. F .& San Diego, CA 92121 .& 866.988.0066 .& www.dtec!)f'om com Page 2/13
---------•-----·-------
Table 2: FCC MPE Umits (from OET-65)
Frequency General Occupational/ Controlled
(l\Ihz) population/Uncontrolled MPE
MPE
(m\\;'/cm2)
(m\'\'/cm2)
30-300 .2 1.0
300-1 500 Frequency (Mhz)/1500 Frequency (Mhz)/300
(0.2 -1.0) (1.0 -5.0)
1500-100,000 1.0 5.0
General population/uncontrolled limits apply in situations in which the general public
may be exposed or in which persons who are exposed as a consequence of their
employment, and may not be fully aware of the potential for exposure or cannot exercise
control over their exposure. Therefore, members of the general public always fall under
this category when exposure is not employment-related.
Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment, and those persons have been made fully aware of the
potential for exposure and can exercise control over their exposure.
Occupational/ controlled limits also apply where exposure is of a transient nature as a
result of incidental passage through a location where exposure levels may be above
general population/uncontrolled limits, as long as the exposed person has been made
fully aware of the potential for exposure and can exercise control over his or her
exposure by leaving the area or by some other appropriate means.
It is important to understand that the FCC guidelines specify exposure limits not emission
limits. Therefore, in order for a transmitting facility or operation to be out of compliance
with the FCC's RF guidelines an area or areas where levels exceed the MPE limits must, first
of all, be in some way accessible to the public or to workers. When accessibility to an area
where excessive levels is appropriately restricted, the facility or operation can certify that it
complies with the FCC requirements.
11526 Somnto Valley Road, Ste. F • San Diego, CA 92121 • 866.988.0066 • www.dtechco,11 (OfJ1 Page 3/13
-------
SITE DESCRIPTION
The subject telecommunication site is located at 5805 Armada Drive, Carlsbad, CA 92008.
Sprint Nextel's site consists of an equipment building located within the building and 12
antennas total. The antennas are mounted inside the parapet walls on the main roof and
connected to the equipment via coaxial cables.
Table 3: Site technical specifications
Num of sectors
N um of Antenna per sector
Antenna Radiation Center
Height Above Ground/Roof
feet
Antenna Type
SN-iDEN850
3
3, 3, 2
39/ NA
(all sectors)
4' panel
(all sectors)
SN-CDMA1900
3
1, 1, 2
39/NA
( all sectors)
RR45-19-04DPL4
( all sectors)
11526 Somnlo Vallry Road, Ste. F .._ Sa11 Diego, CA 92121 .._ 866.988.0066 .._ www.dtechcom.rom Page 4/13
Figure 1: Site map
11526 Somnto VaUry Road, Ste.F A San Diego, CA 92121 A 866.988.0066 A www.dtechi:om com Page 5/13
Dte5}i>
Figure 2: Site Diagram
Site ID: CA6998_5D36XC
·1 N me: PACIFIC GRAND P
Sprint
Sector C
150•
11526 Somnto Valley Road, Ste. F • San Diego, CA 92121 • 866.988.0066 • www.dtechcom com Page 6/13
Figure 3: Site photographs
Sprint-Nextel General site view Sprint-Nextel Access point (locked)
Sprint-Nextel Access sign(s) Sprint-Nextel Sector A (CDM.A)(left) & Sector B
Sprint-Nextel Sector C (CDMA) Sprint-Nextel Sector A (iDEN)
11526 Somnto VaUry Road, Ste.F A San Diego, CA 92121 ..t. 866.988.0066 ..t. www.dtechcom.com Page 7/13
Sprint-Nextel Sector B (iDEN)
Sprint-Nextel Equipment (CDMA)
Sprint-Nextel Sector A (iDEN)Qeft) & Sector A
(CDMA)(right
Sprint-Nextel Sector C (iDEN)
11526 Somnto Valley Road, Ste.F A San Diego, G4 92121 A 866.988.0066 A www dtechcom com Page 8/13
FIELD MEASUREMENT
Field measurements were conducted at the subject site on 12/5/2008 3:00 PM by Jeff Bales,
Dtech Field E ngineer. The Narda meter, model NBM-550 with EA 5091 Probe was used to
conduct the measurements. This device is designed to measure frequencies between 300kHz
and 50Ghz, well within the SMR, Cellular, and PCS frequency ranges (most major wireless
operators). Therefore, the result measured is a cumulative RF energy resulting from all
transmitters within the frequency ranges of the probe. The probe itself is frequency shaped
and can automatically weigh each field contributions based on frequency. The output is
given in percentages of the FCC's MPE Limits. A result higher than 100% is out of
compliance.
As recommended in Safety Code 6, spatial averaging measurement technique was used. An
area between 2 and 6 feet, approximately the size of an average human, is scanned in single
passes from top to bottom in multiple planes. When possible, measurements were made at
very close proximity to the antennae and inside the main beam where most of the energy is
emitted. The maximum levels (max-hold) were recorded.
11526 Sorrento Va!lry Road, Ste. F • San Diego, CA 92121 • 866.988.0066 • wwwdtechcom com Page 9/13
Field M easurement Result
Below are the locations where measurements were conducted and their respective recorded
levels given in percentages of the applicable FCC's MPE Limits. Again, a result higher than
100% is out of compliance.
Figure 4: Result Diagram
Green< " Blue<f20°o Yellow Red=>'100% of_the applicable FCC MPE Limits.
Site ID: CA6998_SD36XC281
Site Name: PACIFIC GRAND PALISADES
Sprint
Sector C
150'
Nextel
SectorC
190°
Sprint
Sector B
90'
On the main roof, the highest exposure level was measured at 15.2% of the applicable FCC's
Occupational MPE Limits (76.0% General Population) near Sprint Nextel's antennas. On
the ground, the highest was measured at 0.45% of the General Population MPE Limits.
11526 Somnto Vall'!Y Road, Ste. F A San Diego, C4 92121 • 866.988.0066 A w1vw.dtechrnm com Page 10/13
RECOMMENDATION(S)
On-site measurements at Sprint Nextel's site resulted in exposure levels below the applicable
FCC's MPE Limits. There are appropriate RF advisory signs posted at the roof access
point(s) and/ or near the antennas to establish awareness for potential RF exposure. Further
actions are not required.
CONCLUSION
Based on the above results, analysis and recommendation(s), it is the undersigned's
professional opinion that Sprint Nextel's site complies with the FCC's RF Safety Guidelines.
The worse-case exposure levels in publicly accessible areas are measured to be well below
the FCC's General Population MPE Limits.
11526 Sorrento Vallry Road, Ste.F A San Diego, CA 92121 A 866.988.0066 A www.dtechmm com Page 11/13
-------·---------
CERTIFICATION
This report has been prepared by or under the direction of the following Registered
Professional Engineer: Darang Tech, holding California registration number 16000, with
renewal date of 06/30/09.
11526 Somnto Valley Road, Ste. F & Sa,, Diego, CA 92121 & 866.988.0066 & www.dteclµ:om com Page 12/13
------------
Appendix A:
References
[1] Guidelines far Evaluating the Environmental Effects of Radio frequency Radiation, Second
Memorandum Opinion and Order, ET Docket 93-62, adopted August 25, 1997.
[2] Guidelines far E valuating the Environmental Effects of Radio frequency Radiation, Report and
Order, ET Docket 93-62, FCC 96-326, adopted August 1, 1996. Federal Register
41006 (1996).
[3] Guidelines far E valuating the Environmental Effects of Radio frequency Radiation, Notice of
Proposed Rulemaking. ET Docket 93-62, 8 FCC Red 2849 (1993).
[4] The Telecommunication Act of 1996, 47 U.S.C. Section 332 (c)(7)(B)(iv).
[5] www.fcc.gov/Bureaus /Engineering Technology/Documents/bulletins/ oet65 /
www.fcc.gov/ oet/rfsafety
11526 Somnto VaUry Road, Ste. F .A. San Diego, CA 92121 .A. 866.988.0066 • www.dtechcom com Page 13/13