HomeMy WebLinkAbout2559 WILSON ST; ; 83-473; Permit.,,
z 0 ;:
C a: C _,
0 ..,
0
C
I[
0 (.J
a: ..,
0 _,
5 ~ .., z 3 0
z 0 ~ .,, z .., ... 2 0 0 .,,
ir ..,
"' a:
0 3:
O I h8feby affirm that I am licensed under
provl1lon1 of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Profeaalons Code, and my license i• 1n
full force and effect.
lie No _____ Class
I hereby affirm that I am exempt from the COnlrac-lo<'s License Law !or lhe lollowIn9 reason (Sec 7031 5
Business and Professions Code Any city or county wh'th re· quires a perm11 to construct. alter improve. dem<>hsh. or repair any slructure. prM>f to its issuance also requires ?heap-
plicant tOf such perrrut to hie a signed stalemenl !hat he 1s
hcensed pursuant lo the prOV1s10ns ol the Contrac1o(s License Law (Chapter 9 C0rMlenc1ng with Secuon 7000 of
DMs1on 3 of 1he Business and Professions Code) or that 1s ex· empt therefrom and the basis lor the auegea exemption Any v1<>ration of 5ect,on 7031.5 by an applicant tor a permit sub·
,ec1s the app1,can1 to a c1VTI penalty ol nol more than frve hun· dre<I dollars ($500)
0 I. as owner ot the prQperty, or my employees wnh wages as their sole compensat,on, wilt do the work, and the struc-
ture 1s no1 mtended 0< ottered fOf sale (Sec 7044. Busmess
and Profess,ons Code. The ContractOf's license Law does nol apply to an owner of properly who builds or improves
thereon and who does such work h1msell or through his own
employees, provided lhat such 1mprovemenls are not intend· ed or offered ICN' safe II. how-ever, the building Of improve· ~nt 1s sold w1lhm one year of comptetion, the owner-bu1kier will have the burden ot proving that he did nol buikl or im·
prove for lhe purpose of sale).
D I. as owner of lhe property. am exctus~ly contracting wI1h licensed contractors 10 construct !he pro,ect (Sec. 7044, Busmess and Proless1ons Code: The Contractor's Ucense
Law does not apply to an owner of property who buikjs or im-proves thereon, and who contracts for each proiects with a
contractor(s) license pursuant to the ContractOf's License Law).
D As a homeowner I am improving my home. and the follow-ing conditions exist: 1. The work is being performed prKX to sale. 2. I have lived in my home for twelve months prior to completion of this work.
3. I have not claimed lhis exemption during the last three years.
□ I hereby affirm that I ha~e a cert1f1cate ol consent
to sell-insure. or a cert1l1cate ot Worke,s
Compensation Insurance, or a cen1hed copy 1hereot
(Sec Jl!OO. I.Abo< Code!
POLICY NO
COMPANY
0 Copy IS hied Wllh the C11y
0 Cen1hed c<>py 1s hereby tu,n1shed
CERTIFICATl OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This seclton need not be completed 1t the perm11
1s IOf one hundred dOllars (S 1001 or less)
0 I certify that in the performance ot the work tor
which lh1s pemut 1s issued. I shall nol employ any
person 1n any manner so as to beeome sub1ec1 to
the Wor1it.ers· Compensation Laws ot Cahtom1a
NOTICE TO APPLICANT It, atte, mak1n4 this Cert,
lteate of Exempt~. you should become sub1ec1 t') the Workers· Compensation pro"1s1ons of lhe Labor
Code. you must torth\Jl.·1th comply with such provisions or lh1s permit shall be deemed re'-IOkecl
O I hereby affirm Iha! there 1s a consuuct,on 1endin~ agency tor the peM01mance ol !he woni. to, which this perm,1 1s 1ssue<1 (Sec 3097 C1v1I Cooe1
Lenders Name __________ _
Lenoer s Address _________ _
USE BALL POINT PEN ONLY & PRESS HARO APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT
1200 Elm, Carlsbad. California 92008-1989 (619) 438-5525
APPLICATION & PERMIT
JOB;;J5-J1 !J..
A ST.RO. NEAREST CROSS ST. l°i:;, /i;n:;ON' BUSINESS LICENSE • 1i1A~O~ PERMIT NUMBER
' 'ff'p ✓t\-1~ , , .::..r)J,..,. ,,
L8T !,\LI/ JIYS:~ sueO'v1s";oN I ASSESSOR PARCEL NO CONTRACTOR l. I CONTRACTORS PHONE • ZONE
/~t'-~/"lrl -'lo ~CV 0 u,,,, I\,, ~ ,,. l]u , IJ~,, 0/4 :ME //4 V rl l! c~ Y---1 I 7 -2 ~~N~,p;;E CONTRACTOR'S ADO RESS LICENSE NO. PLAN 1.0. It BLOG USE COOE
OWNER'S MA LING ADDRESS .
'2S-S-S t.A.///.So ,..J r:Avls/2AJ O~:NiR)
LICENSE tt STANDARO PLAN It BUILOiGLQJ? w ... ,..arr DESCRIPTION OF WORK
-OESIGNER'S AOOR'cY DESIGNER"$ PHONE
~S/d~~t;.J G _N____.Sft V C. h : ,J -F/P F LR ELEV. NO OCC GP EDU '8112, ~FD STORIES !~,~~( '7~~ ;. vO NO ---l a 3 • . a-r'1 -CENSUS TRACT I GP LAND use rr~~ RES UNITS I GRAOING PERMIT ISSUEO I REOEVE LOPMENT TYPE OCC LOAD FIRE SPR AREA CONST
YO N D vO NO vO NO Nor Valid Unlt!Ss Machine Certified
QTY. PLUMBING PERMIT · ISSUE 7,5:a QTY. MECHANICAL PERMIT -ISSUE c.3,0() SUMMARY/ACCOUNT NUMBER I I --ILi-EACH FIXTURE TRAP ...-{ r. -INSTALL FURN. DUCTS UP TO 100,000 BTU ~ -BUILDING PERMIT 01-00-00·8220 .,..., ,J -t EACH BUILDING SEWER -I,, ...r✓ OVER 100.000 BTU , SIGN PERMIT 01 ·00·00·8221 __,
1 EACH WATER HEATER ANO/OR VENT ~-C"i) BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 01·00·00·8806 7A;::,q,7'1
t EACH GAS SYSTEM 1 TO 4 OUTLETS -, _tj ) BOILER/COMPRESSOR 3-15 HP TOTAL PLUMBING 01 ·00·00·8222 ..TY--EACH GAS SYSTEM 5 OR MORE METAL FIREPLACE ~--ELECTRICAL 01 ·00·00·8223 ..r..r -EACH INSTAl .. ALTER, REPAIR WATER PIPE VENT FAN SINGLE DUCT -MECHANICAL 01 ·00·00·8224 /0 -EACH VACUUM BREAKER MECH EXHAUST • HOOD/DUCTS MOBILEHOME 01·00·00·8225
WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP
EACH ROOF DRAIN (INSIDE) SOLAR 01-00-00,RO?~ ~
TQT,t;L MECHANICAL STRONG MOTION 80·92·33·0519 h,~ l> I'
TOT AL PLUMBING I ...I 'I-'-.,, //). FIRE SPRINKLERS 01 ·00·00·8227 --
QTY. ELECTRICAL PERMIT • ISSUE -QTY. SOLAR • ISSUE PUBLIC FACILITIES FEE 32·00·00·8933 IX K/J _.,
,!uOO BRIDGE FEE
NEW CONST EA AMP/SWT BKR -"7' ,w-, vO -COLLECTORS ~ ~ SCHOOL FEE • DISTRICJ
1 PH 3 PH STORAGE~ \l '\ Carlsbad J-:t1L... 80·92·21·0519
EXIST BLOG EA AMP/SWT/BKR ROC'S,,8°f0RA~ y')f. Encinitas 80·92· 22·0519
1 PH 3 PH PJ™P ~ ~IY ,,...f'f I San Dieguito 80·92· 23·0519
REMOOEL.'A LTER PER CIRCUIT ~AN c/iEdMi (f f"\ lO Ql/ I ~Marcos / /80·92· 24·0519 -TEMP POLE 200 AMPS
_....,.
,V/ U I / ( ·--.... L,A,..l_ ~,)f") "\ I -OVER 200 AMPS I JI(/ r ,.. JJI / LICENSE TAX 01-00-00-8162 --TEMP OCCUPANCY (30 DAYS) \ \ (/) V / ~ ..
I'----.. \ / CREDIT DEPOSIT <. ~.-1.r ►
TOTAL ELECTRICAL I .Jr-TOTAi ~
TOTAL FEES PAYABLE-Z.:':J-u>, • .f ~ -1 -V--~'
~
, --J ,·;
I HAVE CAREFULLY EXAMINED THE COMPLETED APPUCA TION AND PERMIT AND DO HEREBY Expiration Every permit issued by the 8u,td1ng Offtc1al under the prov1s1onsofth1s * AN OSHA PERMIT IS REOUlflED FOR EXCAVATIONS OVER CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall exprre by hm1ta1,on and become null and vo,d If the bu1ld,ng o, work 5· o· DEEP AND DEMOLITION OR CONSTRUCTION OF DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT 1$ authorrzed by such permit 15 not commenced w'th'" lSOdays lrom fhe dale of such STRUCTVRES OVER J STORIES IN HEIGHT permit. or 11 the bu1ldinPt or work authorized by such permit 1s suspended or ISSUED TO COMPLY WITH ALL CITY COUNlY AND STATE LAWS GOVERNING BUILDING CON abandoned at any time a ter the work is commenced for a =•1od ol 1Ail davs
STRUCTION WHETHER SPECIFIED HEREIN OR NOT I ALSO AGREE TO SAVE INDEMNIFY AND ~PP I A . :~~ :~ APPROV .o~,
10';1I~~
KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND LC NT GNATURE :/ ~·ER CONTRACTOR 0 ~k--_: J
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ./. O J 0. GRANTING OF THIS PERMIT BY PHONE ..,--..._......-,.,
V'
~
u..
>, rn 0 a.
E Q) I-
I
'O 0 <.'.)
0 1/l 1/l
Q)
1/l 1/l <{
I
~ .Q a:; >-
rti 1/l Q) u 0 a:
"' iii 0
~
Q) u C "' C u:
C Q) ~ <.'.)
0 0 Q) a. 1/l
C
TYPE I DATE INSPECTOR I
BUILDING I
FOUNDATION I \1/U,,~,S ('Jr ·-'I REINFORCED STEEL I
I
MASONRY I
I ·-
GUNITE OR GROUT I
FLOOR & CEILING SUB FRAME I
I
SHEATHING -~ ROOF D SHfAR l,?, ·B+ p. 'I-
FRAME I f.,/1 ~-PY ~,
EXTERIOR LA TH I ~), ~_,Pl ~
INSULATION I f..1~ ·~ (l; fl
INTERIOR LATH & DRYWALL I I~.~ .. ~ II ~ .,,
I -I) I
PLUMBING I
SEWER AND BUCO )2§!PUCO I \ F?·Z·Bf C:
UNDERGROUND )9 WASTE ~WATER j li~·B3 a.. --TOP OUT □ WASTE □ WATER 1-1. lb•Af (' ...
TUB AND SHOWER PAN .,,
I
GAS TEST I ,z_./(,,.(84-_ ~ I
□ WATER HEATER □ SOLAR WATER .
I
ELECTRICAL I
I
□ ELECTRIC UNDERGROUND □ 1UFFER
ROUGH ELECTRIC I 2,,/fi ·A4 ~-If-
□ ELECTRIC SERVICE □ TEMPQRARY V\
□ BONDING □ POOL I
I -
MECHANICAL I
□ DUCT & PLEM., □ REF. PIPING 1,.. th ·M ~
HEAT -AIR COND. SYSTEMS I Yl
VENTILATING SYSTEMS I
I
I
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEEN APPROVED':' ' '
FINAL I .
PLUMBING I 1•.:·
\ •
ELECTRICAL I
I -,
MECHANICAL I
GAS I'S:> ,..._ ,, •, I . -I -' BUILDING ~j~\..,V' r;:,~ \;m Ltt
SPECIAL CONDITIONS \t\~ \J\
I
I
,.
"'· ·, -_, ,., <g3-o~,~ ,._ .r·•
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPEC1 IONS INSPECTOR'S NOTES I ·-.. '• I
/ ' INSPECTION REQ IF INSPECTORS DATE .
CHECKED APPROVAL •. ., -----·-., .,
' SOILS COMPLIANCE
PfllOR TO
rOUNDATION INSP -· ..,. --· . ,5 ,f,84
... STRUCl URAL CONCRETE \rJ.M"'F.12 IJ/\/~ tO \-bll~ 6.t:.. C.Jf-OVER 2000 PSI
PRESTRESSED ~,
CONCRETE -
POST TENSIONED
CONCRETE
' FIELD WELDING
·-HIGH STRENGTH
BOLTS \ ·-.
SPECIAL MASONRY
I
PILES CAISSONS
' ' ---· :.-~ -..•
' -t· -.. ~ -✓,
---'., ',. \ -
,. -,i .• , . ..
.. , r :, ., ..
.
' J '· .. ~
-\ \ ' ~ -\..._ • ' .
•. ' ~ : -, ~ , \,. \ ' ' ' ·-. I /
APPLICATION FOR PERMIT TO CONNECT TO CITY SEWER SYSTEM.
CITY OF CARLSBAD
ENGINEERING DEPARTMENT
438-5541
FOR APPLICANT TO FILL IN
BUI LDING
ADDRESS
OWNER
MAILING
ADDRESS
CONTRACTOR
CONTRACTOR'S
ADDRESS
NEW BUILDING
LEGAL DESCRIPTION
REMARKS:
...: en
I
EXISTING BUILDING
LATERAL LOCATION
ST.
...: en
LATERAL NO. _______ INSTALLATION DATE _______ _.
SE 2 0
ISSUED BY -------------------
DATE ISSUED------------------
VALIDATION
I
------------·-
LATERAL CHARGE COMPUTATION
STANDARD 4" (Max. H. 30', V . 10'), _________ _
OVER 30' H. ___ @.,,, .... • ___ FT. _________ _
OVER 10' V. @ FT. _________ _
STANDARD 6" (Max. H. 30', V. 10') _________ _
OVER 30' H. ___ @. ____ FT. _________ _
OVER '10' V. @ FT. _________ _
TOTAL CONSTRUCTION COST----------
SERVICE CHARGE (REPAVING ETC.)_..!..:::.----,--,-.,.-:-----
TOTAL LATERAL CHAAGE _________ _
LINE COST DATA
ASSESSMENT DIST. NO.---------------
FRONTAGE ____ COST PER FT. ____ TOTAL ___ _
OTHER ____________________ _
CONNECTION FEE
NO. UNITS ___ COST PER UNIT ____ T OTAL----
PUMP STATION FEES
NO. UNITS _~~COST PER UNIT ____ TOTAL __ _ 7
TOTAL CHARGES (LATERAL ETC.) _ ___,l _/o_°I_O __ . _D_0 __ _
WHITE: Engineering GREEN: Finance YELLOW: Sanitation PINK: Building GOLDENROD: Permitter
ESGIL CORPORATION
o a20 CHESAPEAKE nn .. ~l TITE 122
83-473-ZZ: SAN DIEGO, C'A n212a
(619) »00· 1·1,HM
;#e' J} L Y-ffU..:::, t.u I L. L.. .5V 8 s-7'9-A/TIT LL '7 O::u-1,1 ,PL. 'f
tu /TH 771€ cooes .,1 / /.::::::
@I-,£-.SH-du .t!-.D 8e C~JCMZ1P/C::;:7;:;) ~ 7'1k
M 63 .,?'lz:o -fe?::T7 dh I /U 771-G= ~~
/VCL.U.OGS -rhe 'J/'7rZ.-rJ-z:,0 5/0GWJ9-L.L-.:S
su17!'7dl'G ""Jo/l'?y '/t,e ...Ss>C-c/}?._O ~o,Zt4-/VD uJ~-es /2"'r'. 3 )
{I)----t1fe-.i)@t) S~(..)U;:> I-MvGr r-l-1U t:::PSCJ,t:J-Pcr
{,,U/~0 ~s ~tjv/2 477,t;;/'U I Yl.0/ C ~~
t,1..5<:r ;<;~ /9-,Be;-IJ✓-2-oe:;,VJ Dv<1Z1n t:; 711&-L../~
c,r-~ 0,),1!.,0~n_;q .
<itp of <arl.sbab
C:lJGL:(D "Sm1 11~1a A1 t.-
G:) 12-0d ~ s~-!'!""r
@)SV~~
JUKISDICTION1 ________ _ DATE
PROJEC':' ADDRESS I w I '-s () N s, ~
TO; /Je/?L..I C RIV z::
PLAN CORRECTION SHZff
SINGLE PAIIILY
Plan Check No. ____ .1..,::....::.::....-it..;-i:.,..;:a.L. ___ _
Due plan• received by jurisdiction 7)1-Urz lo Z.
:>au plane received by plan checker.r-''2/ • l t>/ZfJ
Date initial plan check c0111pleted ?'ti~ by -:::J"'i,:vJ
F~R£WORDt PLEASE READ // 't!I
Plan check is limited to technical requiruent• contained in the Unitorm Building Code, Uniform
PlumDing Code, Unitorm Mechanical Code, National
Electrical Code and state lavs regulating energy
conservation, noise attenuation and ace••• tor
tne handicapped. The plan check i ■ based on
regulation■ antorced by the Building Inapection
:>apartment. You may have other correction■
based on lavs and ordinances enforced by the Planning Department, Engineering Department
or other departments.
~he item• circled belov need claritication,
modification or change. All circled item■ have tc be satisfied before the plan■ vill be in
ecnformance vith the cited codes and regulation■.
P~r See. lOl (cl, 1979 Uniform Building Code, the approval ct the plans doe■ not permit the
violation of any state, county or city lav.
~
Pie••• make all correction• on the original tracings and submit tvo n-sets of prints, anj any original plan sets that may have
oeen returned to}3~ jurisdiction,
tc.: BL~, ~
j ~o facilitate rechecking, please i dentity,
nex: to eacn circled item, the sheet of
the plans upon which each correction on
th1s sheet has b•en made and return this cneck sheet with the revised plans.
./ lndicate on plans the name ot the legal ;,r· cwner and name ot person responsible tor
tne preparation ot the plans. Sec. 302(b)
3-4-7
0 APPLICANT COPY
~y COPY
D PLAN CHECKER COPY
/. Submit tully dimenaioned plot plan dravn
to scale shoving location size, and uae
of all exiating and propoaed structures
on the lot. Identity property linea and
shov lot dimenaiona and all ea•-•nts. Shov location ot all cut or till alopea
and approximate finiah floor elevation• tor all atructurea and ahow elevation• at
all cornera. Sec. 3021bl7.
Indicate distance fr0111 center-line ot atreet
or all•Y to property line and diatanee from
curb to property line. Sec. 3021bl7
/. Plana, apeciticationa and ealculationa ahall
be aigned by• California State lieenaad engineer or architect. (California
Buain••• and Proteaaions Codel
D. FIRP. PROTECTION
/walla closer than ■hall be one-hour
have no opaninga, parapet• vhan the
1,000 aquara feet
Sec, 1709<al
3 teat to property line■
tire-rated con■truction, and ■hall have 30 inch
building floor area exceed■ on any floor. (Tabla 5-A
/ Projection■, including eave■, may not extend
more than lZ inehea into the l toot setback L' from the property line. Sae. 1710 and
~ See. 5041b)
I:\ 1/projaetiona, including eavea,ahall be ona-;r· hour fira-ra■i■tive con■truction, heavy
timber or of non-colllbustible material it
they project into the 3' ■atback area from the property line. Sae. 1710
,./show location ot permanently wired smoke
/ det-.tctor.. Sac. 1210
C. ROOM SIZES1 LIGHT1 VENTILATIONS AND GLAZING
y. One room must contain a minimum ot 150 aquara
taet of superficial floor area. Sae. 12071b)
/ Habitable room■, other than kitchen■, ahall contain at lea■t 70 square feet ot floor area. Sec. 1207(bl
y.
~1ndov area must~• at least 1/10 ot the
!loor area and a mini mum of 10 square feet per Sec. l207(al. Appears to be deficient
1 n C V:t'OJ. I E l;1 ]I\ J L. \\) I Yb: 4, I H'XNY) ._
:C:~ !)Oy\Jle t)a:)1z c;..L.~ § ?
Openabla vindov area must be 1/20 of the floor area and a minimu~ ot S square teat.
In bathroom■, laundry rooms and similar rooma. Minimum ia 1.5 sq.ft. 1Sae.1205(a)
One-halt ot all required vindov area mu■t be openabl• in _____________ _
/. Provide mechanical ventilation capable of
providing five air chanqas per hour in
bathroom■, water clo■et compartments, laundry
rooms and similar room■ it required vindows are not provided. See. 12D5fal
/ ~o habitable room, other ~han a kitchen,
shall be les■ than 7'0" in any diman■ion. Sec. 1207( c I
l ~ Show that ceiling height tor habitable y· rooma i ■ a minimum ot 7'6". Sec. 1207(al
3-~no~ ce1l1ng ne 1qht tor laundry r oom•,
V, ~a llways , corr1dors. and bat hroom• i• a
~1n1mW11 ot 7'0". Sec. l207Cal
,/Prov1de Jo• clear width tor water clo••t y· comp.ruents and 24" clearance in tront
'
Handrail• ahall ■atisty the following,
a. Provide handrail for atairvaya over 30" high when ••rving a single dwelling.
Title 24, Sec. T25-22(b)
~ b. Handrail •hall be 10• to 34" above the
ot water closet. Sec. 17ll(bl
'~o cooking rooa shall be u•ed tor 1leeping y· ~urpo•••• unl••• <:0111plying a• an efficiency
living un1t. Sec. 1208
,r noaing of tread•. Sec. 3305Cj)
':)~~~7c Handrail projecting from a wall ahAll nJ have a ap.ce not l••• than l 1/2" between
, the wall and the handrail. The hand grip portion of handrail ahall
be not l••• than l 1/4" nor more than ~ \ Spec1ty 1afety glazing for glazing in hazardoua
locat1ona such a• qla•• doors , glazing
adJacant to such doors and glazing adjacent
2• in cro••-••ctional .dilllenai on.
Sac. 3~05(jl ~
? :o walk1n9 •urt.acas . Sec. 5406 ~TM
l .::lazing 1n shower a.nd tub ancloaur•• 1 . .,.
r1ncludin9 windowal shall be tamper d, v._. laaunated or approved plaatic. ..._J"" __ ,,__
Sec. 1711 (fl(ql ~
Every ■tairway landing ■hal l have a dimanaion,
measured in the direction of travel, at
l•a■t equal to the ■tairway width.
Sec. l305(g) I A door may open over a ■tairway landing provided the door, in any po■ition, does
not reduce th• clear area of the landing, in the direction of ■tairway travel, to
Slaep1ng room• shall have a w1ndow or "3>€.~
exterior joor tor emergency exit. Sill neignt anall not exceed 44" above the floo .
The window muat nave an openabl• area of at laaat S.7 square feet with the minim11111
openable width 20 • and th• minia11111 openabl•
he19ht 24". Sec. 1204
·I Eave• and cornice• may not project into ,,,,,n • a raqu1red yard more than 2 i nch•• tor each
toot ot yard width it required window•
/-
open into the yard. Sac. l206Cdl
A mazzan1ne 1• an intarm.diate floor and may not have a floor a.raa exceeding 33 1/3
percent ot the total tloor area in th• room below, and the mezzanine floor mu•t have
a clear ha19ht ot 7 teat, above and below,and must have 6S I of the long ■id• open to the
room below.
The lott you show does not comply a• a
mezzan1n• floor and i s , by Building Coda det1n1t1on, a. story _____________ _
D. !XITS1 STAIRWAYS 1 AND RAILINGS
,5. :l~ors ~cove th• second story shall have
not less tnan 2 exits. Sec. 3302 ta l
46. ~•qu1rad exit doorways shall be not l•••
cnan 36" 1n w1dth and not less than 6 '•8"
in he1qnc, and shall be capable ot opening
at least ~O degrees. Sec. 33031•>
,,. Provide l&" h19n protective railtnq tor
porcnas, balconi••• and open aide• ot landing■.
:ux1mwa opening between railing■ ■hall be l ess tnan 9". Sec. 1716
,a. Show how ~uardra.il connecti on details are
adequa t e to support 20 pounds par l i neal !ooc at~ r ~qnc a.ngle t o th• top rail .
-:'aole ~J-a
?~~vi~• st~~rway a.nd la.ndinq data.ils.
Sec. )3.)5,b) • (C )
~ax1mum rise a• and min1J11um run i • 9".
I
y.
l••• than one-half the required width of
th• ■tairway . Sec. 3305(9>
A door may open inward at the top ■tap of
a ■tairway provided the top atep i■ not
more than 7 1/2" lo-r than the floor level.
Sec. 3303( i) 2
Provide detail• of winding stairway.
a. Hinimum tread ia 6 inch•• at any point
and minim11111 9 inch•• at a point 12 inch••
from the side of t he ■tairway .
b. Maximum ri se ia 9 inch•••
c. HinimWII width i• 30 inch••• <••• attached)
Provi de apical 1tairway detail■a
Sec. 33051d)
a. ~inimum run ia 7 1/2
from where the tread
inch•• at a poinc
is the narroweat.
b. !'laximum ri■• is 9 l/2 inch••·
c. Hinimum headroom ia 6 feet 6 i nch••• Sec. l305Cf) <••• attached)
Sp1ral 1tairwaya :uy not be uaed for required
exit■ when the area ■erved is greater Chan
400 ■q. ft. Sec. 3305(fl
Spiral atairways mu■t have a clear walking
apace ot 26 inch•• between th• column and
handrail. Sec. l305(fl
Provide x.c.a.o. Rea■earch Report and ~WIiber tor metal ■tair~ay, or ■ubmit plans and
calculation■ and approved fabricator r agiatered with the Bui lding Dep.rcment
ar note that the ■tairvey fabrication ■hall
be done under apecial inapeccion per the approved fabrication plana. Sec. 306Ca l48
and Sec. J061fl
In building■ over 2 ■tori•• in height, provide
l /4 hour tire-rated aa1emblie■ tor all opening• in the exterior wall below or within
10 feet hor izontally of an excarior stair• way. An exit balcony with 2 separated
stairway■ is •~~mpt. Sec. 3305
Exterior atai ~~av• shall not project into th• J toot setback from :h• property lines.
S•c. 3J0S(nl
/. 7~e walls and sot!its ot the ~nclosed usable space ~nder interior stairs shal l be protected
on ~~e enclosed side as required !or one-hour ·.:e-resistive construction. Sec. 330S lm)
~inL~WII construction specification• shall
be ~ade a part ct the approved plan•.
,See attac~edl
ROOFING
70. Spec1ty root pi tch.
71. Root pitch is not adequate tor root type •pecitied. Specity minimum pitch or ____ _
~ l l /1" oolid ~,, ,,lt•clooinq doo, tor opening• ~•t~••n garage and dwelling .
Sec. 503Cd>
10/.Garages are not permitted t o open into •
/ _a room used tor 1leeping purposes. See. 1104
·1✓-opening1 between carport and residence
/ require selt-elosing door, and stati onary
yr<. windows. See. 1214
Show garage truing 1ection, size ot header
over garage opening, lateral croa, bracing
at plate line and method ot bracing garage
front. Chapter 23
NOT!I IUni■WI plywood diaphragm ratio ia
3 1/2 to l or 2•1•. Table 24-I
~ CuJ' Speciey root material and application. rYlU~p:~ 7~ Specify I.C.a.o. approval number tor r !'(1;i4z.vAI\
::iatenals not covered in use. (11::: 1'41"l"f)
,-~ Specitl roo t slope tor drainage or design '--~,.__, ✓·-to support accumulated water. Sec. 3207 Ca>
Door• between dwelling• and attached garages
aay awing in either direction provi ded
th• ditterenee in tloor elevation between the dwelling and garage do•• not exceed
7 1/2 inches and provided the door ia not
used aa the priaary mean• ot agr••• tram
the building.
/ Shew root drains and overtlow1. Sec. 3207(a) -✓ Provide skylight details to 1how compliance
/"" witn Sections 3401 and 5207 or provide ICBO
A pproval number.
Provide plastic root panel details to show
compliance with Section 5206 or provide rcao number.
Show attic ventilation. Minimum vent area is 1/150 ot attic area or 1/300 ot attic
area i t at least 501 ot the required vent
is at least 3 r-t above ceiling joi1ts.
Sec. 3205Ccl
a. IIASONRY
Provide fireplace e onatructi on detail• or
note construction to be per attached fireplace standard drawing. Sec. 3707
ai. Show veneer support and connection• comply
/ with Sec. 3002, 4,5,6, and See. 2516Cal regardi ng ti•• and •9 wi re in horizontal
joints or note construction to be perattached
sheets 30-l or 30-2.
R/ Show hu.ghc and construction details ct 7· all :nasonry wal ls. Chapter 24
• Af. ~ote that cleanout openings shall be·provided
/ • at the bottom ot all cells to be grout tilled
over 4' in a single pour. Cleanout shall
oe sealed before grouting, after inspection.
A c. 24 15
how tloor and root connections to masonry lls . Connection sh•ll resist 200 pounds per l ineal toot or the actual design load,
wnicnever is areater. Sec. 2310
Q / Provide mater~al specitications for mortar, ✓-grouc, 1Msonry and rein(orcing ateel.
Sec. 2403
3. Show how 1Maonry houae walls retaining earth
are to be waterproofed. Provide detail.
Noce that s pecial inspection of the maaonry will be requ~r•d tor _____________ _
G. GAAAGE AND CARP<lRTS
100 .~•raqe requires one-hour tire protection on the qarage side ot walls and ceiling
co111111on to th• dwelli ng. Table 5-B Sec.503Cbl
(~.All e,ements supporting tloor above garage :o ,ave one-nour fire-resi■tive protection
on :ne ;araqe side. Sec. 503 . Beams and
po~;s , ,ct w1th1n the wall or ceil1ng con-
str.c:1on, ~ust comply with use, Tabl~ 4)-A, ~roe ~1n1mum 6• dimension beam and m1 n1mum
8" oy :1• post. \J!J.\\!. Sur,t>u•l.t'\v'GJ Ft.., TSi'.'
(1~~ ,_o C.G1 L.I tV11 Ca r'V\ (\ 10 1\) Tb L\Vlr'l "J
~)Ju .. -....___.,___ ....
t
It the ditterenee in floor elevation exceeds
7 1/2 inch••• or it the door ia uaed aa
the pri111&ry meana ot egress from the building, additional step• or landing muat be provided
in accordance with s tairvay requirements, and the door must not swing over the depresaed
level. <••• 330l(il2 and 3305 (9).
Provide 11• raised platform• tor any rAU,
water heater, or any other device which
aay generate• flue or apark.
Note that eontinuoua tire wall protection
1hall be inacalled behind raised platform<•>
prior to truing platform.
rQUNDATIOM R!QOIRpENTS
Note on plan• that•A soil• engineer ahall
eva•luate any unanticipated uncompaeted till
or expansive soil or other aoil problem• diacloaed during eonatructi on•. See.306(all2.
Sub•it soil• claaaitication determination by a licenaed engineer or architect baaed
on observation, teats, borings, or exeavaciona,
and containing co-•nts on the degree ot expanaiven•••• compreasibility and bearing
value. See. 2905
Note on the plan the soils claiaiti eation,
whether or not the soil is expansive, and
noce the allowable bearing value. See. 2905
Th• tound&tion plan doea not comply with
the 1oil report reeol!lll'lendation to~ thia project. __________________ _
l2Y.Provide not•• on the foundation plan listing r the soils report rec0111111endati ona tor foundations.
•lab and building pad preparation.
.
1122~. Note on the foundati on plan that •prior
/ to the Contractor requeating a Building Department foundation inapeeti on, the
aoila engineer shall adviae the Buildinq Official in writing thac1
1. the building pad waa prepared in accor-
dance with the 1oi ls report,
2. the utility trench•• have been properly
backfilled and compacted, and: 3. the foundation excavati on,, terming
and reintorcement comply with the soil•
report and approved plan.•
;.i!: Provide spread footings tor conc11ntrated
• loads designed tor l,000 PSF soil bearing
or per bearing value as determined by
an engin11er or architect. c~apter 29
;~cw ~e1gnt ot all !oundat1on walls. C~apter 23
S~ow ~e1ght of :et31ned eart h on all foundat10n ~ail3. Cha pter 23
"-/9 Show 3l stance ot !oundation to edge of • • :ut or :1ll slopes and show s teepness and
/.
he1~ht s of c~ts and !ills. Chapter 29
: ~oce on ?lans :hat wood shall be 6" above
!1nis h ~rade. Sec. 2417(c l 7. "-r·'-~ote on plans t hat sur face water will drain away !rem buil ding and show drainage pattern
. _/nd ~•Y e l evati ons. Sec. 2905(tl
/· ,1mens1on foundation per Table 29A.
TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING
WALLS-MINIMUM REQUIREMENTS
HPTII a,
,ou111u1a11
WIITII TIIICINISS lllOW
1111111111 TIIICINISS a, a, o, NATIIHI. o, fOUND&TIOII W&U ,aaTINC ,aon111 SUlr&Cl
STOIIU , ...... (IIIClleal (l■UHI a, UOUIII
ANI ,a111111
COIIClffl UNIT IUH MASOllff (IKMII
l 6 6 l:? 6 l:?
:? 8 8 1.5 7 18
3 10 10 18 8 24
SOT'ES:
\Vbeff """'"'"I a»dtbont o, &mt -4.itionl an fowld. f-inp and .. , .. ndAboru U\illl be aa r,quirod m SIICtlOII ;:<J07 tal.
n,., O'DW>d wuur ti.. 11oo, may be ~acanted to tlw ••~•·ation of th•
top of ti.. l-•n1.
Show t oundat1on 11111 to be pressure treated, or equal . Sec. 2517(cl 3.
Show tounda t 1on bolt size and spacing.
Sec. 2907!e l
Spec1ty s1ze , ICBO nwal:ler and manufacturer
ot power driven p1ns. Show edge and end
distance and spacing . Sec. l06(t )
:i/ Show 11:e , 1m.bedlnenc and l ocation of hold
_,;,-· down anchors on foundation plan. Sec. 2312(t)
/· Not e on plan tha t ho l d down anchors muse be t1ed 1n place prior t o f oundati on inspection.
Sec. 2312(t)
Show adequate toot ing• under all shear
walls. Sec. 23ll!e)
Show stepped t oot 1ng1 tor slopes steeper :han 1:10. Sec. 2907(c)
Show m1n1mum 18 " clearance from grade to bottom of floor 301sts and m1nimwn 12•
clearance to bottom ot girders. Sec. 2517
:Lil'! Show p1er 11:e, s pacing and depth into
7·~nd1st ~rcad so1l. ~able 29-A
1 f"'.' Show m1n1mW11 under floor ace••• ot l8"x 24". ·ec. 2517
how m1n1mW11 under floor ventilation equal o l l /2 sq. tt. t or each 25 l i neal teet ot axtar1or foundat ion with openi ngs as
close to corners as practicable ~o provide
cross vent1lat1on on at least two approxi-te•
ly oppos 1te s i des. Sec. 2517
t . PRA.'4tNC
~/snow a ll Jo1sts, ratters , beam■, and posts _;,,,-· 2• co~-cn1ck co be No . 2 Grade Oouglaa
F~r-~•rcn or better . All posts and beama
/.
~• ~nd th1c,er sn•ll be No. l Grade Oougl••
Fu•"•rcn or bet t ar. (Table 25-A•l )
~now wa ll bcac1ng. Every extac1or wood
st~d wa ll and ma1n cr oaa pa rt1t 1on shall
oe oraced st each end and at leeat every
25 !ee t of length w1th l x4 diagonal
l t t•Ln ocsee or equivalent. Sec. 2518(gl5
/ota cross br1dg1ng or blocking. Floo r 'j'i· ~~1ats and ratters mor e than t2• i n depth
and spanni ng mor e :han 8 feet shal l be
support ed laterally by bri dgi ng at 1nter •1ala not exceedi ng 8 teec. Sec . 2506/g l
1.i. Show blocking at ends and at supports 7· ot !loor joists, and for rat ters at ext erior
/
walls. Sec. 2506(g)
Show solid blocki ng at ridge line and
t exterior wall s on trussed roof s.
ec. 2506(9)
hov double joists. Floor joists shall
be doubled under bearin9 parti tions running parallel with the joists. Sec. 2518(dl 5
Shov rafter ti••• Ratter t i es ■hall be
■paced not more than 4 !eet on cente r where rafters and ceiling joists are not
parallel. Sec. 2518(h)
Show rafter purlin braces co be not lea• than 45 degrees co the horizontal. Sec. 251811\l
Show 1/2" min1mwa clearance between top
plate ot 1nterior parci:iona and bott om
chord of tru••••• (To ensure loadi ng will be as de■igned.)
Show double top plate with minimum 48"
lap spl ice. Sec . 25l8(g l 4
Show naili ng wil l be i n compli ance wi th
Table 25-P.
Provide fire stops between s t ories, between
top ■tory and roof apace, at ceilings
and·t l oor levels in interior and ext erior
wall ■, in mansard root or eyebrow so no
concealed or furred apace ia greater than
10' horizontally or vert ical ly, between
stair ■tringera at cop and bottom and between studs along and in l i ne with
■cair run adjoining stud wal l • and parti tions, at perimeter of sliding door pocket s,
between chimney and wood frame using metal
or incombustibles tor t he tire stop and
at other places that could afford passage
of flame. Sec. 2517<f >
Show stud size and spacing. liaximum allow-able ■tud heights, 2•x4•~ 16" is 14 ':
)•x4•,2•xs•9 l6"o.c. i s 20 •. Sec . 25 1819)2
Note an A.I.T,C. Cert1ticata of Compliance
tor glued lamina:ed ·wood memoera shall
be 9iven to the Buildi ng Inspector prior
o erec:ion. Sec. l06(t)
etail all peat co beam and post t o tooting
V. onnectiona. Sec. 2517(cl ~
l Spee1ty na1l a1ze and spaci ng tor all
snear walls, floor and roof d1aphr agms . Indicate required bloc ki ng. ~a1ntain
maximwn di•phragm dimension· rac10■. (Tables I ,J,Xl .
Show l"x4" or 2"x6" scuds in fir st acor-f
of three ■cory building. Sec. 2518!t )
Provide cruaa detail• and truss calculati ons.
Provi de root framing plan. Sec. l02 (a)7
Provide framing secti ons through ______ _
Section J02(al 7
Specify all header sizes !or opening over
4' wide, Sec. 2518(9) 7
Provide calculations tor __________ _
f Secti on J02(a) 7
l • In ar••• subJec: to water splash and 1n exterior locations, wood column• and poses
shall be s~pport ed by piers pr o j ecc1ng
at lease 2• above ch• f i nished grade and
shall bear on a metal base plate or creat ed wood unless :he columns or ?OSts are foun-
dation grade redwood or cedar. See . 2517(cl 4
, -~~c. :=c3t~on of 3tt1c access w1ch m1n1mun
/-· !~:e ~=• x Jo•. Sec. 3205
· L . s~cw =:3r t separ3tion !or attic areas
/
~~ ~xcess of 3,000 sq.!t. Sec . 3205
. 3ncw jr3:~ 5epar3t1on for space between drOppea ceilings and floor above in excess
;I ot l,JOO sq.!c. Sec. 2517
. 6. Specify ?lY"'ood grade"and panel indenci•
!1cat1on 1ndex. Table 25-J
1./ Ahen roof ?ltch 1s less than 3:12, de■ign 7·' ndqe as a bum. Sec. 2518 (hl
7 ~ood shear walls shall not be used to resist hori zontal tore•• contributed by
masonry 1n building• over one story in
he1gnt. See. 2516(bl
21)(': Show ace••• to the attic or under Uoor
/ furnace to be minimwa JO inches by 30
i nches. See . 708, 709 UMC
,~./ Note that ~aaaageway to the attic furnace 7· shall be unobstructed and have continuous
solid flooring not l••• t han 24 inches
wide. Sec 708 UHC fi Shov permanent electrical outlet and
lighting fixture controll ed by a switch for the attic furnace. Sec. 708 UMC
"/ Shov details to c01aply wi th Section •709 7· for furnace under the floor, Section 70 8
for attic furnace, or Section 710 for
roof or outside furnace.
Note on plan, gas vent■ and non-combustible
pipinq paaainq throuqh three floor• or
teas ■hall be effectively draft stopped
at each floor or ceiling. UBC See. 1706(al6 GypsWII lath and pleater, gyp■WII sheathing
:card and qypswa wallboard shall not be ~sed 1n vert1cal diaphragm■ t o r~siac K. ELECTltICAL (National Electrical Code)
!orces 1mposed by masonry or concrete All wiring shall comply with t he National Electric••
construct 1on. Table 47-I ;!:.
!! cr 1pple wal l scuds are less than 14•, 2 . Note on the plan the amperage of electrical !raming snall be solid bloek1ng. Sec.25l8(gl6 service.
:r1pple .all scuds exceeding 4 teec in ,'),f!'f. t! the electrical installation is more
heignt shall be 3 inch by 4 i nch or 2 . than 200 ampere■, shov panel location 1~c~es by 6 1nches when supporting 2 1cor1••· and provide a single line diagram and
Sec. 2s1a1916 load calculacion■ including,
Show ply,oood sheathing over exposed eave■, or ocher weather exposed area■, is exterior
grade . Sec. 2517(9) 3
Shov a weep screed at Che foundation place
line on a l l exterior stud vall■ to be
stuccoed. Sec. 4706(el
Provide an approved waterproof building
paper under wood aiding. Sec. l70l(al
Specify an approved flashing tor exterior
openings and parapet walls. Sec. 3201
Shov corridor width to be minimwa 36•.
Sec. 3304 (bl
Specify truss layout for Jo• x 30• attic
access .
aidqes , h1pa , and valleys s hall be at
leaat one size larger than supported
rafters . Sec. 2518(hl 3
a. Wiring method employed.
b. Size■ ot all conductors, switches,
circuit breakers, fuses, and conduits. e. Approximate length of service feeders.
d. Provide plot plan shoving services, all panel locations, circuit arrangement
and load distribution on panel bu••••·
•· Provide typical panel schedule(■>.
Dwelling■ req-Jir• minimum 100 Ulp servi ce.
Shov location of all electrical recepcaelee.
Electrical receptacle locati~s and,,gr ~1,--•~• spacing 1a not adequate in LE: o ]::S !:J IGC &:. .,...... I
ld.u£ ~ Q., I.Iv, lZ~ i en '941) 8'i? Ila' • 'AV ~Cltl ls:H . ~ At least one receptacle ahal{ be installed
outdoors, in basements and attached qaragea,
other than laundry outlets. Art. 210•25(bl
Show mJ.nimum dwelling lighting ()IEC :799 ./'provide me tal strap■ aero■• ridge beam
and ratters .
Art. 210•26(al and GU,'~ i8':j~rage, bath$,
? and....qucdo,!:~· .. ~ Ar,;.; 21....:__2!;.
Note "UFER" ground to be provided (NEC I.
Art. 250•81 J. MECHANICAL.
All heating, ventilating, and cooling 1y1te■a And appl1•nces shal l comply w1ch the Uniform
~•cnan1cal :ode. ~ Show the s~1-z~e---lo-cac1on and cype ot all
~ neat1ng an ooling appliances or sy■t•••· ,........Gri) ~how source of combustion air for furnace 9-will comply •1th Chaper 6, u.~.c.
Eve ry dwelling ~nit shall be provided with
neat1ng !ac1l1t1es eapable of maintain• ~nq a room temperature of 70° P. at 3
!eet •bove the floor i n all habitable
room■. Show basis for compliance. UBC·
sac. 1211
Show mi nimum 30" deep unobatrueted working space 1n !ront of furnace.
h PLUMBING (Uniform Pluabing Code)
All plumbing shall c0111ply vith the Uniform
Plumbin9 Code.
~ Show water heater size, cype and
location on plans.
,,,<,. Shov method of providing eomoustion aJ.r /.. to fuel burning water heater. See. 1307
,-u""" Puel combustion water heater s hall not be
..,;;,-· installed in bath or bedroom or in a closet openin9 into bath or bedroo■. See. 1309
~
~ote en plans ,clearancea to be
~Jrers .1sc1ng. Sec. 704 UHC
r .r~•~e sna i l not be 1natalled
sta1r-..ay. Sec. 70 4 UMC
per manufae• p___
under any ~
Provide adequate barrier to protect water
heater fr01■ vehicle damage. Sec. 1no
Shov T and P valve on water heater and show route of discharge line co ext erior
See. 1007(el
24
f,r~•=e ~nail not be 1nacalled 1n any ? :e~rocm o•cnroom, clos et, or 1n confi ned ,:ace w1.h Ac cess only through such room,
,nless s~ec1!1ed ~s direct vent appliance,
~n .. =,e~ !Jrnace or eleccr1c heat1ng appliance . ,./
/
;;.c. 10~ :::-1c ~-
snow ::30 approval for prefab fireplace
an~ r rov1de approved 1nscallat1on inacruct1ona
.a t 100 s1te.
Provide dryer vent co outside.
See. 1903 UMC
Note on the plan chat hose bibbs and lawn
sprinkler syttems shall have approved
backtlov prevention devices . Sac. 1003
Shower acall shall aeeomodace a JO"c1rc le and have a ~inimum floor area o t 900 sq.in .
UPC 909(dl
~
::!_a. N :;;;: [',$U;.;.T[CN (DUPLEXES)
:6J. S~:w :e:41:1 == j~plex common (party) wal ls
an= ::oor =e.:1nq sssem0l1es to ach1eve
a ~=-nd ~rsnsm1ss !on Class (STC I rating
1n wa l :s =! 50 jecibles snd a n Impact
In•ulat!on c:ass (I:ci rating on floor/
/ce1l1nq ot 50 dec1bles. Ti\le 25
~-Show new :a netrstion of sssemblie■ tor
p1pinq, ci ectrical dev1ces, rece■■ed cab1neta, batntJbs, sof!1ts , or heat1ng ventilating,
or exnauat ducts snall be sealed, lined, 'or 1naulated t o maintain reqyired sound
tran•m1ss1on rat1ng. Titre 25
2~/. Provide !n■~lation in wal l■ and ceiling 7· to •cn1eve STC ot 50 between garage and
l1v1n9 •re• 1! garage u•• i a not controlled
by rea1dent Title 25 .
!RCY CONSERVATION
l 1dd1:1ons :o ex1st1ng residential
1 l d1nq■ muat comply with Title 24
energy requl •t10ns . Additions exceeding
30\ ot t he ex11ting bu1lding require■ the ex1sting 1nd add1t ion to have R•l9 ceiling
1naul•t 1on 1 ! the axist ing ceiling area
!S 1c:ess10le for 1nsulation install ation
C ~:!l• ~01 (c l .
;,(: Specif/ the 1n■J lat1.on R. value■-for walla,
root •nd ce1ling. (R-11 for wallss R-19 •
tor :eilinqa, or provide details and analysis tor alternate design. T20•1403 Table A, 28, ¢. Specify tlle gro■a floor area or heated
portion■ ot the dwelling, and the area
/of ;lazed opening• on the plan. (T20•1430,
214. Provide •n analysis Justifying increasing
t!le ■1ngle glazed area beyond 161 ot the
grosa floor area. Show method to reduce
heat l oss to that which would occur with bas1: glazing. CT20·1402,det.l
Prov ide energy analys is to shov t hat the
bonnet =•pac1t/ of the gas central furnace does not exceed the bu1ldinq design heat less cy llore than 301. (Exceptions:
~e.000 aTU Hr . output furnace. See also
Cal1tor n1a Etf1c1ency Adjustment.) T2 4•1404
)Iota en ~lan :nat all tranver•• ducts,
plen\J.lls , and f1t:1ng 301nts ot HVAC system
tnall be seal ed with pressure sensitive
I 11
tspe or ~aat10 to prevent air loaa. T20·1404
~ote on pl•n tnat 1nsulat1on ot ducts shall
contorm to U!1C Section 1005 . CT20•1404l l ms
r
7'
I
210
I
I I
211
a 2
Sote on ?l£n t hat all doors and windows to :ne ext erior or to unconditioned area■ 1nall ce fJl ly weacner striped per ANSI
Standard. 1T2 0•l~Oll.
~te on plan chat back draft dampers are
requ1rea on al l fsn systems exhausting •1r !rem t ne 0u1ld1ng. T20•l403
f !ect r1cs l :es.s eance space heecing shall
not ce .J&ed•unless:
a. so, ot neat i ng/cooling 1s suppli ed
b y• nondepletable source.
b . supp1ements a heat pWllp system. c. less than l.J\ ot total heatin<J system.
d. !1!e :ycle .::est analys u ju■titiea . ~iJ •.~04
Sote on ;; an that all heating and coolinCJ
eq~1;;~ent et !1=1 enc1e1 sha ll conform t o
~.:.e :J-~h•Pt•r 2, Subchapter 4, Article 4.
•5, :or !orcad air furnaces l .
~ota =n r•4n tn~t ~o n•tural gas, central
~e4t.~~ ?lane ~•Y oe i nstalled wi thout
an :~t•s~ittent :;n1 t ion Device . T20•1405
E:e=:r1.:: r,s is:~nce ••t er heating i s not
;;er.:11::,.J .Jnl,us ·1er!1ed .is coat 1tffec t1ve cy 4 •• :e .::j.::l e :ost anal ys1s . T20•1406
1tOTl1
Outdoor pool• with fossil fuel heaters
require pool covers as well as other energy
saving devices such •• time clocks, e t c . T20•1406
MISCULAN!:OUS
Show• mini■WII 2• air apace and tlaahing betveen planter and building wells.
Sec:. 2517(el
Specify iuterial to be uaed under the
■hover tile. Sec. 17071al
Specity lath and pleater t o comply vith Chapter 47, uac.
Tvo J/4• copper pipe■ 11Nat be inatall ed troa water heater location to convenient
location ot future solar panels (City Ord.I
Provide sleeve• (root jacks> i n root tor
two tuture l/4• copper pip•• to c~nvenienc
location ot tut~r• solar panels (City Ord.)
Note that solar water piping ia to be inaulated
in •r••• that are not heated or cooled. (City Ord, I
See attachment tor rooting requirements.
The plan■ were revieved baaed on the information shown on
the plana. It the plan• are in error, or changed during
conatruction, the permictee ■hall contact the Building
Department tor reviev and prior approval before proceeding
with the work s
0 Building plana are sub1tant1ally correct
and complete. By1 _________________ _
Oates __________________ _
0 Building plan■ would be subatantially correct
and complete it minor correcti ons are made
at counter.
Bys __________________ _
ildin9 plan■ require major correction• and
coaplete plan recheck, by plan check
engineer, i• r~uired.
Bys ~,fy-1
Dau, \ \ \ al e ~
We -.,ould also be pleaaed to meet with you, at no charge, it
add1t1onal assistance i• needed.
, ,,t111ury t hol coveru ,,ll ••Y Le uao,d only on bulldln,ta ot
,., ••«I Ill .,, u11,111,l:lt:t.. (Cl ty Ores. 80'1))
t 11,· , , 1urJd t1t r ooflnr is r otqulrecs on a ll re,.ldential
,,.,, l I 11,1•., i,t.r GI ty Ord. 8 09J,
1979 EDITION UNIFORM BUILDING CODE 3203
It·) • 1rr-n-11ud11n1 Moof <.:ovrrla1,. A fur-rctardanl rtllll covc:rmtt ~hall
h1: an\' our of the follo\\·mg IIKlfings.
I l\m Cla,, A III lJ huth-up roofm1 as\embl).
~ An) nunc:ral aggregate surfaced buih-up roof for applica1ion 10
ruul\ ha\ m11 a slope nol more 1han 3 ind1t) w 12 ind1t) applied a)
,pc.:1111:d m ~c:c1ion 3203 (di I conm11ng of n01 k)s than 1hr
lollo<A mg:
Moor Uni.
'><•hJ )urta.:c on noncomhus1iblc ma1criah or minimum of '':-inch
pl~" ,lt><l or 1-mch nominal board) or 01 her ma1crial apprO\·ed by
1he ouilJmtt official.
IS;,,r Shttl and Plir,
hmr layer, of Type IS perfora1ed orttani.: fihrr fell. or
1 hree layrr, of Type IS organic or inor11ani.: fitirr fell, and
~urflldn,e Malrrial
.mo p,,und, per roofinJ square of ira\tl, crushc:J rod,, ceramic or
appJ<)\tJ >tnlllar surlacmg ma1erial, or
300 pound) pc:r roohng square of cru\hcll \IJ~.
1~ U.lJ.C ~1andard No. 32-S tor mmnal r.>0fin1 aurrga1e 11,c:i&h-
intt IC\> 1han bO pounds per cubic fool.I
3. An) buih-up roof for applica1ion 10 roofs havtna a slope nol Ins
1han 1: 111.:h w I:? inches applied as spcdried in Scc1ion 3203 (d) I,
.:on)is1ing of nOI less than the follo11,in1:
Roof Drclo.
Sohd surlace on noncombus1ible ma1erials or minimum of •·,-inch
ply11,·ood or I-inch nominal boards or 01her ma1erial approved by
the building official.
Bit~ Slattl Hd Plin
1 \\II layer~ of T)'pe IS organicfibcr felt, or
One layer of 14-pound glau fiber fch base sheet, or combination
sheel, or
One layer of T)·pe 30 organic fiber felt. or
One la)·cr of l)·pc 4S asbes1os fiber fc:h base sheet, and
Citp !,hrrb
One la)·e, of 90-pound mineral surfaced organic fiber felt cap )h«1
(1cqum:s 1101 k)\ than 1wo layers of organic fiber lchl, or
T\\O layers of SS-pound mineral surfaced organic fiber felt split
sh'-"CI, or
One layer of 80-pound mineral surfaced asooto) fiber lch cap )beet,
or
One 1.a,rr ul 72 1"•111uJ 111111rral ,111 lan ·d rla" hllcr h-h ,·ap ,li.·t·I. 111
·1 wo l.i\cl\ 1111 ypt· I~ 11,hc,rm llhcr hni,hmp. fdh
4 Any ('la,, A 111 II prc:pa,cd mohni
S Any ('la\\ ( mmcral ,u, la.-cJ a,phah sl11nttlc~ la1J ,11 thal thcit· au·
n111 lo, 1h,rn l\\11 th1.:lo.11c\\c~ al an) (K11n1 and the 111tal wc111la1 pn
ruofm, ,quarc •~ not Ir" than 23S [K)Und,
t, A,bcstO)•l:Cmcnt )hm11k, 01 ,her,,
7 Concrete slab rool .
II Me1al roof covering
fl Slate )hmelc).
IO. Clay or concrete roof tik
l I. Any wol covering ,y)lem) ol 11,ood shingle) 01 shalo.cs-h.a,·ini; a
C~) Brat in&.
N. ENERGY CONSERVATION: Please Read~
Ne w State Ma ndated Regulations
(Calif . Adm in. Code) be came e ffective
June 16, 1983 and require that the
design sa tisfy one of the alternative
e nergy packages (see attached packages
A, B , C, 1 , 2, 3 , 4 and AB 16 3 ) . The
l aw also r equires that many mandatory
conservat ion items be satisfie d.
C/-?/2LS8;:J.i)is in Zone 7
Copies of the Reside ntial Energy
Conservati o n Manua l may be obtained
from : Publications Unit, California
Energy Commission, 1111 Howe Ave, MS-50,
Sacrame nto, Cali fornia 95825, (Te l.
(916) 920-6216 )). California Building
Officia ls a l so maintain a telephone
"hot line " b e twe e n 10:00 A.M. and Noon
and 1:00 P.M. to 4:00 P.M . a t (916)
-l 56-3823.
~on the title sheet of the plans,
~l t e rnative energy package that
was s e l ect e d i.e . A, B, C, 1, 2, 3,
4, o r AB 163 to s how compliance, and
provide c a l cu l ations and othe r data,
appropriate to that sel ect ed pa~
The r e sponsibl e d esigner s hould sin
a statement, o n the p l a n titles e ,
"The design s ubmitte d s ubstantially
confo rms to the Ene rgy He g ulations
for Reside ntia l Buildings".
Show the "R" value for t he walls and
ceiling and re lated areas.
~ that the i nsulatio n u sed shall
c ompl y with Ca l ifornia Quality Standards. G the insu l ation installer shall
post a signed certificate, in a conspicious
p lac~ in the b uilding, s tating the
i nsu l uti o n complies with Title 24, Chapter
2-53 and Titl e 20 , Chapter 2, Subchapter
4, Ar t i c l e 3.
~oois and windows , i n c luding skylights,
b~tWL~n condit i o ne d a nd non-conditioned
s p 3 cc bh 11 b~ fu l l y weat he rstripped.
~,-;;--t'fu, f 1:i"miQ] L-;r-;t~thu t weather-
,:,t 11 1 i 11 J , ,·c1 u lking or sea l a nts mu s t
1 • : , i t o 1 1 mi t f i 1 t r a tion in the
I .11 1 1111 l m, l o p~ a l t he fol lowing l ocations:
l xt 11, 1 Jo i n t s atound windows and door
1 1 1, ,~; t.~LWL ,'n wa l I so l e p l ates and floors,
a nd b e t ween e xteri or wa ll pa ne l s ;
pe ne trat ions i n wa lls , c e i l i ng s , a nd
f loors for plumb ing , e l ectricit y, a nd
gas line s; openings in a ttic f loor s ;
ahd all other openings in the building
e nvelo pe . .
2 7°. ote that doo r s and windows to be c e rtifie d
Re gulations .
8 . ~ fans e x ha usting air to have back
draft dampe rs .
~a Lthe_erte rj or ,,wall f i iypi_p'?e:)
"Fire place t o have minim~m six square
inc h e s of out s ide air; to have glass
or metal door cove ring the entire opening
of the fireb ox; to have tight-fitting
dampe r with r eadily acce ssible control
and should not have a continuous burning
pilot light".
~ duct s shall comply with Chapter 10,
1976 UMC a nd s hall be tightly s e aled
with mastic or tape.
~ a t the water heater location "wnter
he ate r t o h a ve wrap o f R-12 e xte rnal
~insul a t ion".
~ Note , whe r e water h eat e r i s in unc onditioned
space , the first five fee t of outl e t
pipe to have R-3 wrap.
Note a l l circul a ting hot wate r pipes
i n uncondit ione d spaces shall be insulated.
Note that al l gas fire d heating and
cooling appliances, showe rs and faucets
shall compl y with the Energy Efficiency
Standa rds.
Sho w, a t bath a nd kitc hen, that the
ge ne r a l lighting shall have an efficiency
of not l e ss than 25 lumens per watt
i e . f l o r escent .
t,-:5 that heating or cooling syste ms
~cp t heat pumps) shall have an a utomatic
t he r most a t with me chanism which can be
ma nua lly pro gramme d to automatically
set back the thermos t a t s e t poi nts for
at l e ast two per iods withi n 24 ho urs.
Sh o w the size , type a nd loc ation o f
the spac e he a tin9 (o r c ooling) system
and pro v i d e e ne rgy calculation s if the
o u t put 13TU/llr . e xceed s 4 ':i ,000 13TU/ll r .
o utput.
@~1))2. ~I ~YV
\> ?rl'5U , c. A--rc:>-C
01\) So~
~n ~ JUt-r
w ,~~~
~(t<:-\c:.l)f -
S u~m ,--\-D~
O "-' ~~"-v'v)
-AN O shol,.(/
s 1s4evvi ~ ~e
~\~)?OM~~)
~,~,Yl tl \ So L..~
~ ull W1 ) eJe ,
J urisdicti on {flJ/t!t,~(:i,,t.lL)
P::epared by 1 □ Bl dg. Dep t .
T, 1\/\ VALUATION AND PLAN CHECK FEE □ Esgil
r:AN CHECK NO .
BU I LDING ADDRESS U 1/L-.5CI,</ -~-~~-------------.,,,.----AP FL IC AN T/CONTAC T k t:N H l9Jc!Dt2..S7+ PHONE NO. 7z_9 ... f t,g'Lf
EUILDING OC CUPAN CY g'-3, /1(/ DESIGNER PHONE , ------
TYPE OF CONSTRUC TION v'-A/ CONTRACTOR PHONE -----
BUILDING PORTI ON BUILDING AREA VALUATION VALUE
MULTIPLIER
.,j_ /1/1 N (',,,-J.(,~ (E ~. 5"210 0 '?_-S:5'-fcJ .
~-11 ;,1 t'1 & {fl 3~ ( r)~ 12 ,t>O 75°~Lf .
.~r /O~ ( D ,,/ <;f,o o t;~ 'I
Air Condi t ion i ng
Co:nmercial @ 2 .80
Residential @ 2 40
R~s . or Comm .
F ire Sorink lers @ 1.50
To tal Val u e 9 3 9grg
I
I c -< ,I I u , t "d l II fl e f l e c-I 0 r nergy Regu l a l i ons (r ee x 1.1 )
O lfondi capp e d Re qu l a lions (r ee x 1.06 5)
1. I I I 1 ,t I 1 1 'fi 4'-15", 0 O ____________ _L _______ _
I ' 2.t;CJ, '1S-$
• I
8/4/82
1200 ELM AVENUE
CARLSgAO. CALIFORNIA 92008
QCitp of ([arlsbai:i
Dear Pr operty Owner: ~ ~ f 3 -¼ 3 3
TELEPHONE:
C II
714-438-5525
An application for a building f:ennit ·has been subnitted in your ncune listing yoursel f -• •
as the builder of the propc>Jt:'J :l.rnprove.'llents specified. i:,or your pr otection you should be
aware that as ''owner-builde:c': you are the r esponsible pa~::cy of r e.::ord on such a p-o___rmit.
Buil ding permits are not required to be s i <Jn;ed by _the property _o wners unless they are
personally _ performing tl:eir own -i.\-ork. If your ,·:ork is being perf ormed by scxneone other
than yourself, you.may protect yourself from possibl e liability i f that person applies for
the pro_po__r pennit in his or her I12.J.-qe.
Contractors are re:JUired by l aw to _ be licensed and lxmded by the State of california and
to have a busmess license from the Ci ty of Carl sbad . They are also r equired by l aw to
put the ir l icense number on all permits for which they apply. •
I f you plan to do your own work, with the exception of various trades that you pl an to
subcontract, you shoul d l:e a,,;are of the f ollowing inforrration for your benefit and pro-
tection .. I f you empl oy or otherwise engage any persons other than your immediate famil y ,
ar:rl the ¼-Ork (including roaterial and other costs) is $200 or more for the entire project,
and such persons are not licensed as contractors or subcontractors, then you may l:e an em-
ployer. If you are an employer, you must register wi.th the state and federal government
as an employer and you are subject t o several obligations including state and federal
ii.icane withholding, federal social security taxes, ,·Drkers' compensation insurance, dis-
abil ity ins urance costs, and unemployment contributions. There rr.ay l:e financia l risks
for you if you do not carry out these obligations, and these risks are especial ly serious
with respect to -~-orkers ' compensation insurance.
For specific infornation a.rout your obl igations under federal l aw, c ontact the I nternal
Revenue Service (and, i f you wish, t.r1e U. S. &oa.11 Business Administration). For rrore
specifi c information arout your obl igations under state l aw, contact the Departrrier.t o f
Ber1efit Payments and the Division of Industri a l Accidents.
I f the structure is i ntende.d. for sal e , property owners who are not l icensed contractors
are all owed to perform the ir work personal l y or through their own employees, without
a l icensed contractor or subcontractor, only under limited conditions.
A frequent practice of Q--u.icensed pc__rsons professing to be contractors is to secure an
"owner-builder" building pc.....rmit, erroneously implying that the property rn-mer is providing
h is or her own l abor and ID2l.terial personally. Building pc...rmi t s are not required to be
signed by property rn-mers unless they are performing their own ,,;or k pc>--.rsonally . Info:::IPa-
tion al:out licensed contractors may be obtained by conta cting the Contractors State
License Board in your community or at 1020 N Street , Sacramento, CA. 95814 .
PLE!-\SE COMPLETE AND RETURt\J THE ENCLOSED OWNER-BUILDER VERIFICZ\TION FOffi,1 SO TILZ\.T \-IB CAN
COi>.TFIR.'1 THAT YOU l\RE AWARE OF THESE .MA'ITERS . THE BUIIDING PERHIT WILL NOI' BE I SSUED
UNTIL THE VERIFICZ\TION IS RETURt.'IBD.
Very truly yours,
Building Department
City of carlsb-:id
. 'Ari· '' owr1~:..:biilder"· building' •perrni t ' has been ··ap_E:>li:ed-: f ~r· in your , name and beari.r..g your·-.,-· _. ____ •
signa ture.
Please·.·cornplete· and return--this-inforrriation·.i.'"l the envelope provided at your earl iest-:· . -·-
opportunity to avoid unnecessary d e l ay in processing ar.d i ssuing your building permit.
No building perniit will be i ssued until this verification is r eceived.
1. I personally plan to provide the major lal::or and materials for construction of ..
. the proposed. property irrprovement (yes or no) -fj~ : '·· •
2., I .(bave/ra~~ not) F.,_signed the .applicatioffm:-a building permit. :-, .. ,.
3. · I have contracted ·with the following perso.i (firm) to provide the _proposed construction.
Name -------------Phone --------------. .
, • ·· . Address ------------Contractors License No . -----
.··.: .· City ___ _;_ ___ -____ _
:. 4 ~ . I plan to provide portions of the ·work;· but I have hired the following p=:-__r~on to
• _. · cCXJrd.inate, supervise and provide the major \-.--ark. • • . -. . . .
-Name -------------Phone
Address ------------Contractors License.No . -----
City ____________ _
...__ -2.:_ I will provide some of the wor k · but I have contracted (hirE<l} the foll~wing pc='JSOns
t o-.pJ:Qvide the ·work indicated:
.Address Phone
Signed, Property Cll-mer ~~
Social Security Nu-nber SC/9 -7. -79
Date: Oc:--
Type of Work
EAC~ SUB CO~TRAC TCR WILL BE INSTRUCT ED TO OBTA IN A CITY OF CAR LSBAD
sus n;ESS LICENSE At~D FURMI SH A CER T IFICATE OF t-l OR.l<M.'l.t-:·s CO '.·iPE:•!3.!H IO'.~
TC TH :: C I T Y O F C!-\ R L S BA D • it(
Ini t i a l s -------
-·-------------·----------·-·-•►--•-·------,--·
habitare' design group
environmental & graphic consultants
1144 state st. suite 10 san diego, ca. 82101 234-5371
NOV . 28, 1 98 3
KENNETH HARDESTY
2555 Wilson s t.
Carlsba d, ca.
92008
RE: Soil investigation a t
Sir,
Par cel 2 of lot split map 11 95 3
A PN 1 5 6 1 3 0 3 0
In a ccorda nce with your request, I have inspected
existing soil conditions of above property.
Based on visual inspection, the soil i s in a natural,
undisturbed condition, consisting of sandy clay and
clayey gravel.
Per t a ble 29-B of the U.B.C. an a ppropriate allowable
f oundation pressure would be 1000-1500 P. S. F.
Typical footing design should be based on t able 29-A
of the U.B.C.
If upon completion of trenching operations , exposed
soil is not consistent with these findings a more
deta iled investigation is r e commended .
If you have any questions please call.
RESPECTFULLY,
EL L . CATHER-ARCHITECT
C-013558