HomeMy WebLinkAbout1215 WIND STAR WAY; ; CB973344; PermitV 07 d 4--7 B u I L D I N G p E R M I T
01/12/98 11:12
Page . 1. of 1
Permit No: CB973344
Project No: A970430 0
Development No: F2005002
Job Address: 1215 WIND STAR WY Suite:
Permit Type: SINGLE FAMILY DWLNG -DETACHED
Parcel No: 212-212-10-00 Lot#: 47
Valuation: 271,180 Construction Type: VN
Occupancy Group: Reference#: CT95-05 Status:
Description: PLAN 3,3264+713 GAR+82 SF DECK Applied:
: PHASE 2,SALTAIRE-MONARCH COMMUNITIES Apr/Issue:
Entered By:
714 363-7010
ISSUED
10/20/97
01/12/98
RMA
STE 180
Appl/Ownr : MONARCH COMMUNITIES
30012 IVY GLENN DR
LAGUNA NIGUEL CA
Plan Check Numbers
Fees Required ***
> ~;1~7 CB971266,PC 97~~01/12/98 0001 01
*** Fees Collected & Crecfr~T
Fees:
Adjustments:
Total Fees:
16,584.83
.00
16,584 .83
Total Credits:
Total Payments:
Balan ce Due:
.00
350 .00
16,234.83
Fee description Units Fee/Unit Ext fee Data
Number of Bedrooms > 3 3.00
Number of Bathrooms > 3.00 3.00
Building Permit 1242.00
Plan Check 807.00
Strong Motion Fee 27,00
or Enter Park-in-Lieu Fee & Acct#) 1575 1575.00
Enter "Y" to Autocalc P.F.F. > 4935 .00
Enter "Y" to Autocalc T .I. ' > 540.00
Payoff Fee for CFD > 4698.83 4698.83
Enter #Units & Code-Potable Wa t er > 1 2400.00
Enter 11yu for Plumbi ng Issue Fee > 20.00
Each Plumbing Fixture or Trap > 19 7.00 133.00
Each Building Sewer > 1 15.00 15.00
Each Install/Repair Water Line > 1 7 .00 7.00
Each Water Heater and/or Vent > 1 7.00 7.00
Gas Piping System > 1 7.00 7.00
Each Vacuum Breaker > 2 7 .00 14.00
Enter II y U for Electric Issue Fee > 10.00
Single Phase Per AMP > 200 .25 50.00
Enter ' y , for Mechanical Issue Fee> 15.00
Install Furn/Ducts/Heat Pumps > 3 9.00 27.00
Each Install Fireplace > 3 6.50 19 .50
Each Exhaust Fan > 4 6.50 26.00
Each Install/Reloc Vent > 2 4.50 9.00
INS? KB
CLEAH.+-· .. """"~-------
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
3
y
y
D5/8
y
y
y
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB973344 FOR 09/17/98
DESCRIPTION: PLAN 3,3264+713 GAR+82 SF DECK
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
TYPE: SFD
STE:
INSPECTOR AREA RB
PLANCK# ORIG CB9
OCC GRP
CONSTR . TYPE VN
LOT: 47 JOB ADDRESS: 1215 WIND STAR WY
APPLICANT: MONARCH COMMUNI TIES
CONTRACTOR:
PHONE: 714 363-7010
OWNER:
REMARKS: C/JAMES/929-3188
SPECIAL INSTRUCT:
TOTAL TIME:
CD
19
29
39
49
DATE
LVL DESCRIPTION
ST Final Structural
PL Final Plumbing
EL Final Electrical
ME Final Mechanical
DESCRIPTION
091198 Final Elect rical
082098 Gas/Test/Repairs
*****
072798 Interior Lath/Drywall
072798 Exterior Lath/Drywall
072098 Insulation
071798 Insulation
071598 Rough Combo
071498 Rough Combo
071398 Rough Combo
061998 Shear Panels/HD's
061898 Shear Panels/HD's
061798 Shear Panels/HD's
061698 Shear Panels/HO'S
061598 Shear Panel s/HD's
061098 Roof/Reroof
042798 sewer/Water service
042398 Underground/Under Floor
042398 Sewer/Water Service
041598 Underground Combo
032598 Underground/Under Floor
032598 Sewer/Water Service
PHONE:
PHONE:
INSPECTOR I
ACT COMMENTS
tlf ______ _
INSPECTION HISTORY *****
ACT INSP COMMENTS
AP RB EMR
AP RB
AP RB
AP RB
AP RB
NS RB WORKING BEFORE 7 AM
AP RB
NS RB
co PD COULD NOT FIND SUPER
AP RB
NS RB
CA RB
CA RB
NS RB
AP RB
AP RB
CA RB
CA RB
AP PS
AP RB HAS B.W. VALVE
PA RB SEWER ONLY
L BUILDING INSPECTION
DEPT: BUILDING FIRE PLANNING CMWD ST LITE
PLAN CHECK#: CB973344
PERMIT#: CB973344
PROJECT NAME: PLAN 3,3264+713 GAR+82 SF DECK
DATE: 09/14/98
PERMIT TYPE: SFD
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
ADDRESS: 1215 WIND STAR WY Lot# 47
SEP I 7
CONTACT PERSON/PHONE#: C/FRANZ/929-0257
SEWER DISTt CA WATER DIST: CA
-==============================-=======-=====================
INSPEC DATE cr(rt/1 ~ BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
===============================================-=============================
COMMENTS:
.,.
FINAL BUILDING INSPECTION
ENGINEERING FIRE e CMWD
PLAN CHECK#: CB973344
DEPT: BUILDING
PERMIT#: CB973344
PROJECT NAME: PLAN 3,3264+713 GAR+82 SF DECK
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
ST LITE
DATE: 09/14/98
PERMIT TYPE: SFD
ADDRESS: 1215 WIND STAR WY Lot# 47
CONTACT PERSON/PHONE #: C/FRANZ/929-0257
SEWER DIST: CA WATER DIST: CA
==--=====---------------------==----------------======--=====================
INSPECTED DATE q. ,1 j&, ✓ BY: M1z INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
------------------------------------------------========-========---------===
COMMENTS:
FIN~ING INSPECTION
DEPT: BUILDING ENGINEERING V PLANNING CMWD ST LITE
PLAN CHECK#: CB973344 DATE: 09/14/98
PERMIT#: CB973344 PERMIT TYPE: SFD
PROJECT NAME: PLAN 3,3264+713 GAR+82 SF DECK
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
ADDRESS: 1215 WIND STAR WY Lot# 47
CONTACT PERSON/PHONE#: C/FRANZ/929-0257
SEWER DIST: CA WATER DIST: CA
=========---------------------------------------=======-==================---
INSPECTED~ 0 f-_ DATE
CJ (j_g_/ 1i INSPECTED: APPROVED A DISAPPROVED BY: · o-l~ I J
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
----=----------------------------------=--------=================------------
COMMENTS:
FINAL BUILDING
DEPT: BUILDING ENGINEERING
PLAN CHECK#: CB973344
PERMIT#: CB973344
FIRE PLANNING
PROJECT NAME: PLAN 3,3264+713 GAR+82 SF DECK
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
ADDRESS: 1215 WIND STAR WY Lot# 47
CONTACT PERSON/PHONE#: C/FRANZ/929-0257
SEWER DIST: CA WATER DIST: CA
LITE
DATE: 09/14/98
PERMIT TYPE: SFD
~PPROVED~ DISAPPROVED _
INSPECTED
BY:
INSPECTED
BY:
COMMENTS:
DATE
INSPECTED:
DATE
INSPECTED:
&P ?tzT(?
APPROVED
APPROVED
DISAPPROVED
DISAPPROVED
SEP I 4 1998
:' ' r r -~
'
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING
PLAN CHECK#: CB973344
PERMIT#: CB973344
FIRE PLANNING
PROJECT NAME: PLAN 3,3264+713 GAR+82 SF DECK
CMWD
PHASE 2,SALTAIRE-MONARCH COMMUNITIES
g
DATE: 09/14/98
PERMIT TYPE: SFD
ADDRESS: 1215 WIND STAR WY Lot# 47
CONTACT PERSON/PHONE#: C/FRANZ/929-0257
SEWER DIST: CA WATER DIST: CA
=================-=--------------------------------------------==============
INSPECTED
i1~
DATE qfr(p (q[ BY: INSPECTED: APPROVED J.,,,-"' DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
===============================--====-=======================================
COMMENTS:
SOUTHWEST INS~ECfI6N AND TESTING INC.
10826 S. Norwalk #A
Santa Fe Springs, CA 90670
714-526-8441 Fax-562-946-0026
===================================================================----=---=----
FIELD DATA ON TEST SPECIMENS
ASTM C31, C138, C143, C172, C173, C231, C1064
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: 1215 WIND STAR WAY
JOB NAME: SALT AIRE
ARCHITECT: CTA
JOB#: 7265 DATE: 5/19/98
PERMIT#: 973344 ISSUED BY: CARLSBAD
ENGINEER: SPECIALTY STEEL
CONTRACTOR: MONARCH SUB CONTRACTOR: DI CARLO --------------------------------------------------------------------------------LOCATION IN STRUCTURE: EXT. FOOTINGS LIVING AREA BACK LOT 47 --------------------------------------------------------------------------------CONCRETE SUPPLIER : ESCONDIDO PLANT: 02
TYPE OF CEMENT: V ADMIXTURE:
SLUMP: 3 3/4" WATER ADDED: 10
CONCRETE TEMP: 74 MIXING TIME: 1:00
MIX#: 6 37PAE
TICKET#: 229634
AIR TEMP: 68
TIME CAST: 9:05
-------------------------------------------------------------------------------
DATE CAST: 4/17/98 RECEIVED AT LAB: 4/20/98 -------------------------------------------------------------------------------
SPECIMENS MADE BY: STEVE ST. GERMAIN SPECIFIED PSI: 4500 -------------------------------------------------------------------------------FIELD IDENTIFICATION A B C D E F -------------------------------------------------------------------------------LAB IDENTIFICATION : 802917 : 802917 : 802917
----------------------1---------1---------1---------1--------1--------1--------
AGE DAYS 7 28 28
DATE TESTED 5/15 4/24 5/15
SIZE-IN. 6X12 6X12 6X12
AREA-SQ. IN 28.27 28.27 28.27
CRUSH LOAD-LBS 161000 120000 167500
COMP-STR.-PSI. 5694 4244 5924
I H/D
CORR FACTOR
CORR. STR. -PSI
TIME TESTED -------------------------------------------------------------------------------
REMARKS: ------------------------------------------------------------------------------ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
BREAK TYPE A: X B: C: D: E:
-------------------------------------------------------------------------------
SAMPLES CAST BY OTHERS:
FULL WITHOUT THE APROVAL OF SIT!
SUBMITTED
PECTION AND TESTING
OS ARD. ANDRES
LAB. MANAGER
ASTM C39 BREAKS A= cone B= cone and split C= cone D= shear E= columnar