HomeMy WebLinkAbout2800 ATADERO CT; ; CBR2024-1352; PermitBuilding Permit Finaled
Residential Permit
Print Date: 09/16/2025
Job Address: 2800 ATADERO CT, CARLSBAD, CA 92009-9201
Permit No:
Status:
(cityof
Carlsbad
CBR2024-1352
Closed -Finaled
Permit Type: BLDG-Residential
2551012200
$51,289.80
Work Class: Second Dwelling Unit
Parcel#: Track#:
Valuation: Lot#:
Project#:
Plan#:
Occupancy Group:
#of Dwelling Units: 1
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#:
Occupant Load: Plan Check#:
Code Edition:
Sprinkled:
Project Title:
Description: JENSEN: NEW 292 SF DETACHED ADU
Applicant: Property Owner:
PERMITS IN MOTION
TERRY MONTELLO
4152 60TH ST
JENSEN FAMILYTRUST06-12-12
2802 ATADERO CT
SAN DIEGO, CA 92115-6301
(619) 994-5557
FEE
BU ILDING PLAN CHECK
CARLSBAD, CA 92009-9201
BU ILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN)
CERTIFICATE OF OCCUPANCY
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SFD & DUPLEXES
STRONG MOTION -RESIDENTIAL (SMIP)
SWPPP INSPECTION TIER 1 -Medium BLDG
SWPPP PLAN REVIEW TIER 1 -Medium
Total Fees: $2,957.17 Total Payment s To Date: $2,957.17
Applied: 05/28/2024
Issued: 11/06/2024
Finaled Close Out: 09/16/2025
Final Inspection: 06/30/2025
INSPECTOR: de Roggenbuke, Dirk
Contractor:
SPECIALTY HOME IMPROVEMENT INC
539 SHADYWOOD DR
ESCONDIDO, CA 92026-1426
(760) 738-6270
Balance Due:
AMOUNT
$864.50
$204.00
$107.00
$21.00
$3.00
$1,374.00
$6.67
$292.00
$85.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information w ith the City Manager for processing in accordance with Carlsbad M unicipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
~$00
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check c/;>,eJd). Y -'l,,SSJ
Est. Value i:.SZJ -28 °I. 8d
PC Deposit S 86'{. So
Date .5/eNVd lf
Job Addres~tadero Court Unit: APN:255-101-22 -----
CT/Project #: __________________ Lot#: 354 Year Built: _1_9_7_8 _______ _
BRIEF DESCRIPTION OF WORK: Proposed adu w/ storage above the bathroom and closet
□ New SF : Living SF,292 Deck SF, ___ Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Un it? O Y O N New Fireplace? O YE) N , if yes how many? ___ _
D Remodel:. _____ SF of affected area Is the area a conversion or change ofuse? O YON
0 Pool/Spa:. _____ SF Additional Gas or Electrical Features? ____________ _
0 Solar: ___ KW, ___ Modules, Mounted:QRoofQGround, Tilt: 0Y0 N, RMA: CY ON,
Battery:OYC N, Panel Upgrade: OY ON Electric Meter number: -------------0th er:
APPLICANT (PRIMARY CO TA ) PROPERTY OWNER
Name ....... =-T""rt=-~---::--'----:---:'-7-:--~+-------Name: Jarett Jensen
Address:2802 Atadero Court :=i-....;.~....;...:....,._~~-=---1:--=--~..--....... ..-:::=-
, .................. 5 .... __ city:, _C_a_r l_s_b a_d _______ St ate: _C_A __ Zip: 92009
·.:.::.L....,1......1...,.;.....;_~:::....:::;.......;_...-...,... __ ,...,... ___ Phone: 760-81 5-7843
Email.: _ _.,_._...._ ......... _._ .......................... _.__....._ ______________ Email: ____________________ _
DESIGN PROFESSIONAL
Name: Jesse Leon
Address: 10245 Casa Court
City: Santee State:_C_A __ Zip: 92071
Phone: 619-733-8134
Email:iessealeon@hotmail.com
Architect State License : N/A ------------
CONTRACTOR OF RECORD
Business Name:Specialty Home Improvement Inc
Address: 539 Shadywood Drive
City: Escondido State: CA Zip: 92026 ---Phone: 760-738-6270
Email: sheen@specialtyhomeimprovementcom
CSLB License #: 799853 Class: B --------
Carlsbad Business License# (Required): BLOS1240294
APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I
agree to comply with all City ordinances and State laws relating to building construction.
REV. 04122
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
{OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaf firm under penalty of perjury that I am /icensedunder provisions of Chapter 9 ( commencing with Section 7000) of Division]
of the Business and Professions Code, and my license is in fu/lforceand effect. I also affirm under penalty of perjury one of the
following declarations(CHOOSE ONE):
D I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of t he
work which this permit is issued. Policy No. ____________________________________________ _
-OR-
D I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: _______________________ _
Policy No. _____________________________ Expiration Date: ________________ _
-OR-
[) Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: _______________________ lender's Address: _______________________ _
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All improvements exiS1ong on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): Jesse Leon SIGNATURE: ~ ~)!,, DATE: 5120124
Note: If the person signing above is an authorized agent for the contractor rovide a let~zation on contractor letterhead.-----------
-OR-
{OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license l aw does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Cont ractor's license Law).
-OR-
D I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" Is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Cade, is available upon request when this application is
submitted orot the following Web site: http://www.leginfo.ca.gov/calaw.html.
OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city"s approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: __________ DATE: ______ _
Note: If the erson si nin above is an authorized a ent for the ro ert owner include form B-62 si ned b ro ert owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
REV. 04/22
PERMIT INSPECTION HISTORY for (CBR2024-1352)
Permit Type: BLOG-Residential Application Date: 05/28/2024 Owner: TRUST JENSEN FAMILY TRUST
06-12-12
Work Class: Second Dwelling Unit Issue Date: 11/06/2024 Subdivision: CARLSBAD TCT#73-18 UNIT#05
Status: Closed -Finaled Expiration Date: 10/22/2025 Address: 2800 ATADERO CT
IVR Number: 56669 CARLSBAD, CA 92009-9201
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 283129-2025 Passed Dirk de Roggenbuke Complete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
06/26/2025 06/26/2025 BLDG-Final Inspection 288905-2025 Partial Pass Dirk de Roggenbuke Relnspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency B-59 needed No
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
06/30/2025 06/30/2025 BLDG-Final Inspection 289327-2025 Passed Dirk de Roggenbuke Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency B-59 needed Yes
Received B-59
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, September 16, 2025 Page 4 of 4
PERMIT INSPECTION HISTORY for (CBR2024-1352)
Permit Type: BLDG-Residential Application Date: 05/28/2024 Owner: TRUST JENSEN FAMILY TRUST
06-12-12
Work Class: Second Dwelling Unit Issue Date: 11/06/2024 Subdivision: CARLSBAD TCT#73-18 UNIT#05
Status: Closed -Finaled Expiration Date: 10/22/2025 Address: 2800 ATADERO CT
IVR Number: 56669 CARLSBAD, CA 92009-9201
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
BLDG-SW-Inspection 281360-2025 Partial Pass Dirk de Roggenbuke Reinspection Incomplete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
04/17/2025 04/17/2025 BLDG-16 Insulation 282030-2025 Passed Dirk de Roggenbuke Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-18 Exterior 282032-2025 Passed Dirk de Roggenbuke Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Inspection 282186-2025 Partial Pass Dirk de Roggenbuke Reinspection Incomplete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
04/25/2025 04/25/2025 BLDG-17 Interior 282955-2025 Passed Dirk de Roggenbuke Complete
Lath/Drywall
Tuesday, September 16, 2025 Page 3 of 4
PERMIT INSPECTION HISTORY for (CBR2024-1352)
Permit Type: BLDG-Residential Application Date: 05/28/2024 Owner: TRUST JENSEN FAMILY TRUST
06-12-12
Work Class: Second Dwelling Unit Issue Date: 11/06/2024 Subdivision: CARLSBAD TCT#73-18 UNIT#05
Status: Closed -Finaled Expiration Date: 10/22/2025 Address: 2800 ATADERO CT
CARLSBAD, CA 92009-9201 IVR Number: 56669
Scheduled
Date
04/09/2025
Actual Inspection Type
Start Date
Inspection No.
Checklist Item
BLDG-Building Deficiency
BLDG-13 Shear Panels-HD (ok
to wrap)
BLDG-15 Roof
Sheathing-Reroof
COMMENTS
BLDG-SW-Inspection
Checklist Item
276536-2025
COMMENTS
Are erosion control BMPs
functioning properly?
Are perimeter control BMPs
maintained?
Is the entrance stabilized to
prevent tracking?
Have sediments been tracked
on to the street?
Has trash/debris accumulated
throughout the site?
Are portable restrooms
properly positioned?
Do portable restrooms have
secondary containment?
04/09/2025 BLDG-23 281358-2025
Gas/TesURepairs
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-27 Shower
Pan/Tubs
281 359-2025
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-84 Rough
Combo(14,24,34,44)
281188-2025
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Tuesday, September 16, 2025
Inspection Primary Inspector
Status
Partial Pass Dirk de Roggenbuke
Passed Dirk de Roggenbuke
Passed Dirk de Roggenbuke
Passed Dirk de Roggenbuke
Reinspection Inspection
Passed
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Passed
Yes
Passed
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Complete
Page 2 of 4
Building Permit Inspection History Finaled
(city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2024-1352)
Permit Type: BLDG-Residential Application Date: 05/28/2024 Owner: TRUST JENSEN FAMILY TRUST
06-12-12
Work Class: Second Dwelling Unit Issue Date: 11/06/2024 Subdivision: CARLSBAD TCT#73-18 UNIT#05
Status: Closed -Finaled Expiration Date: 10/22/2025 Address: 2800 ATADERO CT
IVR Number: 56669 CARLSBAD, CA 92009-9201
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/17/2025 01/17/2025 BLDG-21 273656-2025 Passed Dirk de Roggenbuke Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-31 273657-2025 Passed Dirk de Roggenbuke Complete
Underground/Conduit•
Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-SW-Pre-Con 273784-2025 Passed Dirk de Roggenbuke Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/30/2025 01/30/2025 BLDG-11 274804-2025 Passed Dirk de Roggenbuke Complete
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 1 /30/25 footings/ slab rebar/ hardware/ Yes
vapor barrier/ Ufer ok for concrete
BLDG-SW-Inspection 275039-2025 Partial Pass Dirk de Roggenbuke Reinspection Incomplete
Checklist Item COMMENTS Passed
Are erosion control BMPs Yes
functioning properly?
Are perimeter control BMPs Yes
maintained?
Is the entrance stabilized to Yes
prevent tracking?
Have sediments been tracked Yes
on to the street?
Has trash/debris accumulated Yes
throughout the site?
Are portable restrooms Yes
properly positioned?
Do portable restrooms have Yes
secondary containment?
02/19/2025 02/19/2025 BLDG-83 Roof Sheating, 276535-2025 Passed Dirk de Roggenbuke Complete
Exterior Shear (13,15)
Tuesday, September 16, 2025 Page 1 of 4
True Nortl1
COMPLIANCE SERVICES
September 23, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
City of Carlsbad -FINAL REVIEW
City Permit No: CBR2024-I 352
True No11h No.: 24-018-462
Carlsbad, CA 92008
Plan Review: Residential New ADU & Storage
Address: 2802 Atadero Ct
Applicant Name: Terry Montello
Applicant Email: pennits@pennitsinmotion.com
OCCUPANCY AND BUILDING SUMMARY:
Occupancy Gro ups: R-3
Occupant Load: N/ A
Type of Constructio n: V-B
Sprinklers: No
Stories: Two
Area of Work (sq. ft.): 292 sq. ft.
The plans have been reviewed for coordinati on with the permit application.
Valuation:
Scope of Work:
Floor Area:
Confirmed
Confirmed
Confirmed
Attn: Building & Safety Department,
True North Compliance Services, Inc. has completed the final review of the fo llowing documents fo r the project
referenced above on beha lf of the City of Carlsbad:
I. Drawings: One (I) copy dated May 22, 2024, by Jesse Leon.
2. Structural Calculations: One (1 ) copy dated April 26, 2024, by Coastline Engineering.
3. Geotechnical Repo11: One (I) copy dated March 14, 2024, by SB Consultant, Inc.
4. Other Documents: One (I) copy dated July 12, 2024, by SB Consultant, Inc.
5. Other Documents: One (I) copy dated May 22, 2024, by City of Carlsbad.
6. Other Documents: One (I) copy dated June 11 , 2024, by Coastline Engineering.
The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 202 1 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 Californ ia
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562. 733.8030
Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review.
Please note that our review has been completed and we have no further comments.
We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any
questions or if we can be of further assistance.
Sin cerely,
True North Compliance Services
Review By: Qamar Aloqaily -Plan Review Engi neer
Stru ctural Review By: A laa Atassi -Plan Review Engineer
Transmittal Letter
June 4, 2024
City of Carlsbad
Community Development Department -Building Division
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review: Residential New ADU w/ Storage
Address: 2802 Atadero Ct, Carlsbad CA
True North
COMPLI ANCE SERVICES
FIRST REVIEW
City Permit No: CBR2024-l 352
True North No.: 24-018-462
Applicant Name: Terry Montello Applicant Email: perrnits@permitsinmotion.com
True North Compliance Services, Inc. has completed the review of the following documents for the project
referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list.
1.
2.
3.
Drawings: Electronic copy dated May 22, 2024, by KL Drafting and Design.
Structural Calculations: Electronic copy dated April 26, 2024, by Coastline Engineering.
Geotechnical Report: Electronic copy dated March 14, 2024, by SB Consultants, Inc.
Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of
work on the permit application. See below for information if the scope of work on plans differs from the permit
application:
Valuation:
Scope of Work:
Floor Area:
Confirmed
Confirmed
Confirmed
Our comments follow on the attached list. Pl ease call if you have any questions or if we can be of further
assistance.
Sincerely,
True North Compliance Services
Review By: Qamar Aloqaily -Plan Review Engineer
Quality Review By: Alaa Atassi -Plan Review Engineer
True North Compliance Services, Inc.
8369 Vickers Street, Suite 207, San Diego, CA 92111
T / 562. 733.8030
Residential New ADU w/ Storage
2802 Atadero Ct
June 4, 2024
Plan Review Comments
HARD COPY -RESUBMITT AL INSTRUCTIONS:
City of Carlsbad-FIRST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page2
Please do not resubmit plans until all departments have completed their reviews. For status, please
contact building@carlsbadca.gov
Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans
for commercial/industrial projects (THREE sets of plans fo r residential projects). Corrected sets can be
submitted as follows:
Deliver THREE corrected sets of plans and TWO corrected calculations/reports directly to the City
of Carlsbad Building Division, 1635 Faraday Ave., Carlsbad, CA 92008, (442) 339-2719. The city
will route the plans to True North, Planning and Land Development Engineering Departments (if
applicable) for continued review.
Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific
instructions for resubmittal review. The city will not route plans back to Dennis Grubb &
Associates fo r continued Fire Prevention review.
GENERAL INFORMATION:
A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical
Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020
NEC, as amended by the State of California).
B. There may be other comments generated by the Building Division and/or other City departments that will
also require your attention and response. This attached list of comments, then, is only a portion of the plan
review. Contact the City for other items.
C. Respond in writing to each comment by marking the attached comment list or creating a response letter.
Indicate which details, specification, or calculation shows the required information. Your complete and
clear responses will expedite the re-check.
D. Where applicable, be sure to include the architect and engineer's stamp and signature on all sheets of the
drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This
item will be verified pri or to plan approval.
OCCUPANCY & BUILDING SUMMARY:
Occupancy Groups:
Occupant Load:
Type of Construction:
Sprinklers:
Stories:
Area of Work (sq. ft.):
R-3
NIA
V-B
No
Two
292 sq. ft.
ARCIDTECTURAL COMME TS:
A I . Sheet A 1:
Residential New ADU w/ Storage
2802 Atadero Ct
City of Carlsbad-FIRST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page3
June 4, 2024
a) Copy the following notes onto the plans:
i) Bathtub and shower floors and walls above bathtubs with installed shower heads and in
shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces
shall extend to a height of not less than 6 feet above the floor. CRC R307 .2
ii) Gypsum board shall not be used where there will be direct exposure to water, or in areas
subject to continuous high humidity. CRC R702.3.7. l
b) Revise the smoke alarm to be located at least 20 feet from a permanently installed cooking
appliance. CRC R314.3.3.
i) Smoke alarms are pennitted to be located at least 10 fee t from a permanently installed
cooking appliance if the smoke alarm is an ionization smoke alarm with alarm
silencing switch, or photoelectric smoke alarm in accordance with CRC R314.3.3 (4)
Exception.
3'-o· ' ' -.. . : ,, I a d I
I I
I I
.> I d
.>~
.:,, I
I
I I
I I I I I I I 0 I I >< \
I ~ \
I \ '
c) Indicate on the plans, the type, location, and size of the building address which must be clearly
visible and legible from the adjacent public way or street. Address letters/numbers shall be
minimum 4 inches hi gh, with a minimum stroke width of 1/2 inch, and shall contrast with their
background. CRC R3 19 .1.
d) On the plan, show enclosed rafter space ventilation per CRC R806. l.
i) Show the number of vents and calculation to justify the quantity is adequate to provide l
square feet of ventilation per 150 square feet of vented space. CRC R806.2.
ii) Specify a 1-inch minimum space between the bottom of the roof sheathing and the
insulation. CRC R806.3.
iii) Ensure cross-ventilation is provided where the addition and existing roof occurs.
MECHANICAL COMMENTS:
Ml. All new low-rise residential buildings must have a whole house ventilation system that provides a calculated
minimum amount of outdoor air by using either a continuously running bathroom fan or a supply or return
air ventilation thru a central HV AC system. The minimum ventilation volume must be a minimum of 1
c.f.m. for each 100 sq. ft. of floor area plus 7.5 c.f.m. for each occupant. The number of occupants is
determined by multiplying the number of bedrooms and then adding one. ASHRAE 62.2
M2. Sheet A-1:
a) Note on plans for kitchen and restroom exhaust termination: Air ducts shall exhaust and 3 '-0"
from openings into the building. CMC 504.5.
Residential New ADU w/ Storage
2802 Atadero Ct
City of Carlsbad-FIRST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page4
June 4, 2024
b) The following comments apply to the washer/dryer:
i) Note the following on the plans:
( l) Exhaust duct termination is as follows per CMC 502.2:
(2)
(3)
ELECTRICAL COMMENTS:
E l. Sheet Al:
(a) 3 feet from a property line,
(b) 10 feet from a forced air inlet, and
(c) 3 feet from openings into the building.
Exhaust duct shall not discharge onto a public way. CMC 502.2
Unless otherwise permitted or required by the dryer manufacturer's installation
instructions and approved by the city, domestic dryer moisture exhaust ducts shall
not exceed a total combined horizontal and vertical length of fourteen feet,
including two 90-degree elbows. Two feet shall be deducted for each 90-degree
elbow in excess of two. CMC 504.4.2.
a) Provide a GFCI, waterproof, and tamper resistant receptacle outlet at the front and rear of the
building per CEC 210.8, 406.9(B), 406.12, and 210.52(E).
b) Specify all kitchen receptacles to be GFCI protected.
PLUMBING COMMENTS:
Pl. Sheet A 1:
a) At showers, address the following:
i) Specify the shower door to be 22" minimum per CPC 408.5.
ii) Shower door shall open so as to maintain a 22" minimum unobstructed opening for egress
per CPC 408.5.
iii) Show the location of the shower head and control valves. Controls for the showerhead
shall be located on the sidewall of the shower compartment so that the showerhead does
not discharge directly at the entrance to the compartment per CPC 408.9.
iv) Showers are required to have a minimum 2" curb per CPC 408.5. Revise the plans to show
compliance.
b) Provide the following dimensions on the plan for the water closets per CPC 402.5:
i) Side clearances -15" from the centerline of the water closet to the walls or obstacles.
ii) Front clearance -24" in front of the water closet.
c) Provide seismic strapping for the water heater per CPC 507.2.
i) Strapping shall be at points wi thin the upper one third and lower one-third of the water
heater.
ii) At the lower point, a minimum distance of four inches shall be maintained above the
controls with the strapping.
Residential New ADU w/ Storage
2802 Atadero Ct
City of Carlsbad-FffiST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page5
June 4, 2024
GREEN BUILDING COMMENTS:
No comments.
ENERGY COMPLIANCE COMMENTS:
Tl. Sheet Al: Address the following comments:
a) Note on plans: All lighting to be high efficacy. CEnergyC 150.0(k) l(A)
b) Revise plan to show interior lighting fixtures to be equipped with dimming controls. CEnergyC
150.0 (K)(2)(F)
c) Revise plan to show at least one lu.minaire in the bathrooms to be controlled by a vacancy sensor.
CEnergyC 150.0(k)2(E)
d) For exterior lighting, specify luminaires to be high efficacy and shall meet the fo llowing
requirements, as applicable per CEnergyC 150.0(k)(3):
i) Controlled by a manual ON and OFF switch that does not override to ON the automatic
actions of Items b) or c) below; and
ii) Controlled by photocell and motion sensor. Controls that override to ON shall not be
allowed unless the override automatically reactivates the motion sensor within 6 hours; or
iii) Controlled by one of the following methods:
(1) Photocontrol and automatic time switch control.
(2) Astronomical time clock.
(3) Energy management control system.
T2. All new residential units are required to be Energy Storage System (ESS) ready. Provide the following on
the plans per CEnergyC 150.0(s):
a) At least one of the fo llowing shall be provided:
i) ESS ready interconnection equipment with a minimum backed-up capacity of 60 amps and
a minimum of four ESS-supplied branch circuits, or
ii) A dedicated raceway from the main service to a panelboard (subpanel) that supplies the
branch circuits in Section 150.0(s)(2). All branch circuits are permitted to be supplied by
the main service panel prior to the installation of an ESS. The trade size of the raceway
shall be not Less than l inch. The panelboard that supplies the branch circuits (subpanel)
must be labeled "Subpanel shall include all backed up load circuits."
b) A minimum of four branch circuits shall be identified and have their source of supply collocated at
a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply the
refrigerator, one lighting circuit shall be located near the primary egress and at least one circuit
shall supply a sleeping room receptacle outlet.
c) The main panelboard shall have a mini.mum busbar rating of225 amps.
d) Sufficient space shall be reserved to allow future installation of a system isolation
equipment/transfer switch wi thin 3 feet of the main panelboard. Raceways shall be installed
between the panelboard and the system isolation equipment/transfer switch location to allow the
connection of backup power source.
Residential New ADU w/ Storage
2802 Atadero Ct
June 4, 2024
City of Carlsbad-FIRST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page 6
T3. Water heaters using gas that serve individual dwelling units shall include the following per CEnergyC
150.0(n):
a) A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the water heater and
accessible to the water with no obstructions. The branch circuit conductors shall be rated at 30 amps
minimum. The blank cover shall be identified as "240V ready." All electrical components shall be
installed in accordance with the California Electrical Code.
b) The main electrical service panel shall have a reserved space to allow for the installation of a double
pole circuit breaker for a future water heater installation. The reserved space shall be permanently
marked as "For Future 240V use."
T4. Systems using gas cooktop to serve individual dwelling units shall include the following per CEnergyC
150.0(u):
a) A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the cooktop and
accessible to the cooktop with no obstructions. The branch circuit conductors shall be rated at 50
amps minimum. The blank cover shall be identified as "240V ready." All electrical components
shall be installed in accordance with the California Electrical Code.
b) The main electrical service panel shall have a reserved space to allow for the installation of a double
pole circuit breaker for a future electric cooktop installation. The reserved space shall be
permanently marked as "For Future 240V use."
STRUCTURAL COMMENTS:
S 1. Submit a letter from the geotechnical engineer confirming that the foundation plan, details, and
specifications have been reviewed and that it has been determined that the recommendations in the
geotechnical report are properly incorporated into the plans. Alternatively, the geotechnical engineer may
stamp and sign the foundation plan and all sheets containing foundation details.
S2. Structural calculations page 13 of 25: Structural calculation indicates the redundancy factor, p, is 1.0.
Provide explanation or calculation to justify use of l.0 instead of 1.3. ASCE 7-16 Section 12.3.4.
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
3.31 PSF
3.31 PSF
AREA
210SQFT
TRII
MUI
S3. Structural calculations page 16 of 25: the calculations how the shear wall segment length is 8', while the
upper floor framing plan shows it to be 12'. Please revise and coordinate.
Residential New ADU w/ Storage
2802 Atadero Ct
June 4, 2024
SHEAR WALL
SEGMENT UNGTH
SEGMENT HEIGHT
ASPECT RATIO
REDUCTION IN SEISMIC SHEAA PANEL CAPADTY
City of Carlsbad-FIRST REVIEW
City Permit No.: CBR2024-1352
True North No.: 24-018-462
Page 7
UPPER ROOF FRAMING PLAN
If you have any questions regarding the above comments, please contact Qamar Aloqaily via email
qamara@tncservices.com or telephone (562) 733-8030.
[END]
COASTLINE
ENGINEERING
structural engineering services
(760) 436-1 344
www.CoastlineEngi nc.c om
STRUCTURAL CALCULATIONS
JENSEN ADU
2802 ATADERO COURT,
CARLSBAD,CA 92009
PROJECT NUMBER: 24-013
4/26/2024
CALCULATED BY: M.I.
REVIEWED BY: -
DESIGNER
KL DRAFTING & DESIGN
(619) 733-8134
www.kidrafting.com
CLIENT
SPECIALTY HOME IMPROVEMENT
COASTLINE
ENGINEERING
DESIGN LOADS
VERTICAL LOAD ANALYSIS
LATERAL LOAD ANALYSIS
FOUNDATION ANALYSIS
2 -3
4 -8
9 -23
24
TABLE OF CONTENTS
GOVERNING CODES
2022 CALIFORNIA RESIDENTIAL CODE (CRC)
WOOD
CONCRETE
MASONRY
STEEL
ALUMINUM
M INIMUM DESIGN LOADS
ANSI/AWC NDS-18 / ANSI/AWC SDPWS-21
ACI 318-19
TMS 402-16 / TMS 602-16
ANSI/AISC 360-16 / ANSI/AISC 341-16 / AISI S100-16/S200-20
ADM-20
ASCE/SEI 7-16
1 of 24
JENSEN ADU
24-013
4/26/2024
,------✓,,
COASTLINE
ENGINEERING
ROOF LOADS
RLl
COMP. SHINGLE/ BUILT-UI
SHEATHING
FRAMING --INSULATION -DRYWALL
OTHER
i
DEAD LOAD
LIVE LOAD
TOTAL LOAD
FLOOR LOADS
Fll
HARDWOOD FLOORING
SHEATHING
FRAMING -DRYWALL -OTHER
~
-
2
2 -3
2
3
1.5
13.S PSF
20 PSF
33.S PSF
4
2.5
3
3
1.5
I ,-
-
DEAD LOAD
LIVE LOAD
TOTAL LOAD
EXTERIOR WALL LOADS
EWl
STUCCO
SHEATHING
FRAMING
INSULATION
DRYWALL
OTHER
DEAD LOAD
LIVELOAD
TOTAL LOAD
14 PSF
40 P5F
54 PSF
10
1
1.5
1
3
1.5
18 PSF
18 PSF
RL2
-
FL2
--~
·-
-
·--
EW2
DESIGN LOADS
,_
,_
,_
,_
,~
,.,. --,~
,_ -•-,~ -~--,--
•-·
2 of 24
JENSEN ADU
24-013
4/26/2024
I
---i
--i
-I
~
I
I
COASTLINE
ENGINEERING
INTERIOR WALL LOADS
IWl
DRYWALL x2
FRAMING -OTHER --
5.5
1.5
1.5
,_
DEAD LOAD 8.5 PSF
LIVE LOAD
TOTAL LOAD 8.5 PSF
I
I
I
I
I
I
I
I
I --~
f
I
I
IW2
DESIGN LOADS
,~
,-
~
,_
,.----,_
,_
__ ,_
,----
·-
-,_
~ ,,~
--
,_
-
·-
3 of 24
JENSEN ADU
24-013
4/26/2024
I
I
i
I
--i
I
,~
I,
COASTLINE
ENGINEERING
BEAM LOADS
4 of 24
JENSEN ADU
24-013
4/26/2024
Note: This sheet shows the loading calculations only, beam design is on the sheet(s) that follow. Loads from other calculated beams and lateral elements (i.e.
shear walls above) are applied directly on the beam design sheet(s). A summary of the beam reactions follows the beam calculations.
2ND FLOOR/ LOW ROOF LEVEL
RB-1 GRID LINE 3
LOAD TYPE I RLl EWl TOTAL
Wl TRIB. LENGTH 7.5 6.5 D= 0.218 KLF
D 0.101 0.117 Lr= 0.150 KLF
Lr (L) 0.150 L=
W2 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W3 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W4 TRIB. LENGTH D=
D Lr=
Lr (L) L=
Pl TRIB. AREA D=
D Lr=
Lr (L) L=
P2 TRIB. AREA D=
D Lr=
Lr (L) L=
P3 TRIB. AREA D=
D Lr =
Lr (L) L=
P4 TRIB. AREA D=
D Lr=
Lr (L) L=
RH-1 GRID LINE A
LOAD TYPE I RLl EWl TOTAL
Wl TRIB. LENGTH 5 1.5 D= 0.095 KLF
D 0.068 0.027 Lr= 0.100 KLF
Lr (L) 0.100 L=
W2 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W3 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W4 TRIB. LENGTH D =
D Lr=
Lr (L) L=
Pl TRIB. AREA D=
D Lr=
Lr (L) L=
P2 TRIB. AREA D=
D Lr=
Lr (L) L=
P3 TR/8. AREA D=
D Lr=
Lr (L) L=
P4 TRIB. AREA D=
D Lr=
Lr (L) L=
COASTLINE
ENGINEERING
I Multiple Simple Beam
UC#: KW-06016271, Build:20.24.04.09
Project Title:
Engineer:
Project ID:
Project Descr:
Coastline Engineering, Inc.
Description : 2ND FLOOR/ LOW ROOF LEVEL BEAMS & HEADERS
Wood Beam Design : RB-1
S of 24
JENSEN ADU
24-013
4/26/2024
Project File: 24-013.ec:6 I
(c) ENERCALC INC 1983-2023
Calculations per NDS 201 8, IBC 2021, ASCE 7-16
BEAM Size :
Wood Species :
Fb -Tension
Fb-Compr
Applied Loads
6x10, Sawn, Fully Unbraced
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Douglas Fir-Larch Wood Grade : No.1
1,350.0 psi Fe -Prll 925.0 psi Fv 170.0 psi Ebend-xx
1,350.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx
Unif Load: D = 0.2180, Lr= 0.150 k/ft, Trib= 1.0 ft
Design Summary D 2
-
1,600.0 ksi
580.0ksi
Density 31 .210 pcf
Max fb/Fb Ratio =
fb : Actual : 0.239 • 1 400.76 psf at
1,674.32 psi
+D+Lr
3.875 ft in Span# 1 ------·-----
Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv : Actual: Fv : Allowable :
Load Comb :
0.154 : 1
32.75 psi at
212.50 psi
+D+Lr
Max Reactions
Left Support
Right Support
(k) Q !.r .L 0.84 0.58
0.84 0.58
Wood Beam Design : RH-1
6.975 ft in Span # 1
ax De ecbons
'ti. Transient Downward
Ratio
LC:
Transient Upward
Ratio
6x10 ..
7.750 ft
0.019 in Total Downward 0.048 in
4777 Ratio 1947
Lr Only LC: +D+Lr
0.000 in Total Upward 0.000 in
9999 Ratio 9999
LC: LC:
Calculations per NDS 2018, IBC 2021, ASCE 7-16
BEAM Size :
Wood Species :
Fb -Tension
Fb-Compr
Applied Loads
4x6, Sawn, Fully Unbraced
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Douglas Fir-Larch Wood Grade : No.2
900.0 psi Fe -Prll 1,350.0 psi Fv 180.0 psi Ebend-xx
900.0 psi Fe -Perp 625.0 psi Ft 575.0 psi Eminbend -xx
Unif Load: D = 0.0950, Lr = 0.10 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual :
Fb : Allowable :
Load Comb :
0.446 • 1
647.51 psf at
1,451.66 psi
+D+Lr
3.125 ft in Span # 1
1,600.0 ksi
580.0 ksi
Density 31 .210 pcf
Max fv/FvRatio =
fv : Actual :
0.181 : 1
40.84 psi at
225.00 psi
+D+Lr
6.250 ft
Fv : Allowable :
Load Comb :
Max Reactions (k)
Left Support Right Support
Q !.r
0.30 0.31 0.30 0.31
5.813 ft in Span # 1
1 'ti. !::!
ax De lections
Transient Downward 0.044 in Total Downward 0.087 in
Ratio 1687 Ratio 865
LC: Lr Only LC: +D+Lr
Transient Upward 0.000 in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
COASTLINE
ENGINEERING
BEAM LOADS
6 of 24
JENSEN ADU
24-013
4/26/2024
Note: This sheet shows the loading calculations only, beam design is on the sheet(s) that follow. Loads from other calculated beams and lateral elements (i.e.
shear walls above) are applied directly on the beam design sheet(s). A summary of the beam reactions follows the beam calculations.
2ND FLOOR / LOW ROOF LEVEL
FH-1 GRID LINE 2
LOAD TYPE I Fll IWl TOTAL
Wl TRIB. LENGTH 3.25 1.5 D= 0.058 KLF
D 0.046 0.013 Lr=
Lr (L) (0.130) L= 0.130 KLF
W2 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W3 TRIB. LENGTH D=
D Lr=
Lr (L) L=
W4 TRIB. LENGTH D=
D Lr=
Lr (L) L=
Pl TRIB. AREA D=
D Lr=
Lr (L) L=
P2 TRIB. AREA D=
D Lr=
Lr (L) L=
P3 TRIB. AREA D=
D Lr=
Lr (L) L=
P4 TRIB. AREA D=
D Lr=
Lr (L) L=
~
COASTLINE
ENGINEERING
Multiple Simple Beam
UC#: KW-06016271, Build:20.24.04.09
Wood Beam Design : FH-1
BEAM Size :
Project Title:
Engineer:
Project ID:
Project Descr:
Coastline Engineering, Inc.
7 of 24
JENSEN ADU
24-013
4/26/2024
Project File: 24-013.ec:6
(c) ENERCALC INC 1983-2023
Calculations per NOS 2018, IBC 2021, ASCE 7-16
Wood Species :
4x6, Sawn, Fully Unbraced
Using Allowable Stress Design with IBC 2021 Load Combinations, Major Axis Bending
Douglas Fir-Larch Wood Grade : No.2
Fb -Tension
Fb -Compr 900.0 psi Fe -Prll 1,350.0 psi Fv 180.0 psi Ebend-xx
900.0 psi Fe -Perp 625.0 psi Ft 575.0 psi Eminbend -xx 1,600.0 ksi
580.0 ksi
Density 31 .21 O pcf
Applied Loads
Unif Load: D = 0.0580, L = 0.130 k/ft, Trib= 1.0 ft
Design Summary
Max fb/Fb Ratio =
fb : Actual : Fb : Allowable :
Load Comb :
Max fv/FvRatio =
fv : Actual :
Fv : Allowable :
Load Comb :
0.248 ; 1 288.66 psi at
1, 165.28 psi
+D+L
0.136: 1
24.49 psi at
180.00 psi
+D+L
Max Reactions
Left Support
Right Support
(k) Q
0.12 0.12
1r !.
0.28
0.28
2.125 ft in Span # 1
3. 797 ft in Span # 1
'ti.
D(_O.OS!!Q) L@_13Ql__
----. ---. -----...
.!::!
ax De ect1ons
Transient Downward
Ratio
4x6
4.250 ft
0.012 in
4127
LC: L Only
Transient Upward 0.000 in
Ratio 9999
LC:
Total Downward
Ratio
Total Upward
Ratio
0.018 in
2854
LC:+D+L
0.000 in
9999
LC:
-
RB-1
GRID: 3
RH-1
GRID: A
FH-1
GRID: 2
-
COASTLINE
ENGINEERING
D
RB-1: Rl 0.840
RB-1 : R2 0.840
RH-1 : Rl 0.300
RH-1 : R2 0.300
FH-1: Rl 0.120
FH-1 : R2 0.120
BEAM REACTIONS SUMMARY
FACTORED LOADS {K)
ASD LOAD CASES
UNFACTORED LOADS {K) EXCLUDING W,E INCLUDING W,E
Lr L w E CN-Sl E CE-WI MAX. MIN. MAX. MIN. MAX.
0.580 1.420 0.504 1.936
0.580 1.420 0.504 1.936
0.310 0.610 0.180 0.856
0.310 0.610 0.180 0.856
0.280 0.400 0.072 0.592
0.280 0.400 0.072 0.592
--~ ~
8 of 24
JENSEN ADU
24-013
4/26/2024
LRFD LOAD CASES
INCLUDING 00
MIN. MAX. MIN.
0.621 1.936 0.621
0.621 1.936 0.621
0.222 0.856 0.222
0.222 0.856 0.222
0.089 0.592 0.089
0.089 0.592 0.089
I
I
I
I
7
·1
l
i
I
~
COASTLINE
ENGINEERING
TOTAL DEAD LOADS (USED FOR SEISMIC DESIGN)
ROOF LEVEL
LOAD TYPE UNIT D.L. I AREA I HEIGHT 1 LENGTH 1 I HEIGHT 2 LENGTH 2 I HEIGHT 3 LENGTH 3 I HEIGHT 4 LENGTH 41 TOTAL
RLl 13.5 210 ----2.835 K
FLl 14.0 ---
EWl 18.0 -6 so 2.700 K
IWl 8.5 6
I = 210 SQFT I = 5.535 K
FLOOR LEVEL
LOAD TYPE UNIT D L. I AREA I HEIGHT 1 LENGTH 1 I HEIGHT 2 LENGTH 21 HEIGHT 3 LENGTH 3 I HEIGHT 4 LENGTH 4 1 TOTAL
RLl 13.5 170 ----2.295 K
FLl 14.0 80 --1.120 K
EWl 18.0 -8 85 6.120 K
IWl 8.5 8 20 0.680 K
I = 250 SQFT WALLS ABOVE 2.700 K
I= 12.915 K
9 of 24
JENSEN ADU
24-013
4/26/2024
,,.---,,,
COASTLINE
ENGI NEERING
SEISMIC DESIGN FORCES (EQUIVALENT LATERAL FORCE PROCEDURE)
SESMIC DESIGN CRITERIA
RISK CATEGORY
IMPORTANCE FACTOR (10)
SITE CLASS
II
1.00
C
MAIN SEISMIC FORCE-RESISTING SYSTEM
WOOD SHEAR WALL
R 6.5
0 • 0 3
Cd 4
c, 0.02
X 0.75
6. 0.025h
SITE SPECIFIC PARAMETERS
s, 1.007
Si ______ 0.364
Soi 0.364
Sos 0.805
SEISMIC DESIGN CATEGORY D
PERIOD
hn
Ta = C,(hn)x
k
15.25'
0.154 SEC
1
• WHERE APPLICABLE, REDUCTION FOR FLEXIBLE DIAPHRAGMS IS APPLIED ON
LATERAL BRACING ANALYSIS SHEETS
SEISMIC BASE SHEAR
C, = S05I./R 0.124
0.363
~ GOVERNS
C,. MAX. = 5011.f (TR)
C,. MIN = 0.44Sosle <' 0.01 0.035
C, MIN.= O.SS1l0/R (IF S1.: 0.6) N/A
V=C,W 2.285 K
VERTICAL DISTRIBUTION OF SEISMIC FORCES
Fx = C.,.,.V
C.,.,. = Wxhx "/(IW;h,")
LEVEL
ROOF
FLOOR
w.
5.535 K
12.915 K
h,
15.25'
8.50'
Fx (LRFD)
0.993 K
1.292 K
F, (ASD)
0.695 K
0.904 K
DISTRIBUTION OVER DIAPH.
Fx (LRFD) F, (ASD)
4.73 PSF
5.17 PSF
3.31 PSF
3.62 PSF
VERTICAL DISTRIBUTION OF SEISMIC FORCES FOR DIAPHRAGMS, CHORDS, & COLLECTORS
Fpx = (IF/IW,)Wp,
Fp,, MIN.= 0.2Sosl,Wpx
Fpx. MAX = 0.4SosleWpx
LEVEL F X (LRFD)
ROOF 0.993 K
FLOOR 2.079 K
F X (ASD)
0.695 K
1.456 K
COLLECTORS & THEIR CONN. • •
DISTRIBUTED OVER DIAPH. INCREASE BY 25% INCREASE BY 00
F X (LRFD) F X (ASD)
4.73 PSF 3.31 PSF
8.32 PSF 5.82 PSF
F X (LRFD) F X (ASD) F X (LRFD) F X (ASD)
5.91 PSF 4.14 PSF 11.82 PSF 8.28 PSF
10.40 PSF 7.28 PSF 20.79 PSF 14.56 PSF
•• 25% LOAD INCREASE SHALL BE USED AT BUILDING PORTIONS
BRACED BY WOOD LIGHT FRAMED SHEAR WALLS,
OTHERWISE OVERSTRENGTH LOADS SHALL BE USED
10 of 24
JENSEN ADU
24-013
4/26/2024
COASTLINE
ENGINEERING
11 of 24
JENSEN ADU
24-013
4/26/2024
WIND DESIGN PRESSURES (ENVELOPE PROCEDURE, PART 1)
WIND PRESSURE 1
N-S GRID LINES A _j
E-W GRID LINES 1 !
ENCLOSURE CLASSIFICATION ENCLOSED
ROOF TYPE GABLE/ HIP
NUMBER OF STORIES 2
DIRECTION OF RIDGE EAST-WEST
RISK CATEGORY II
BASIC WIND SPEED (V} llOMPH
EXPOSURE CATEGORY C
Kd 0.85
Ku 1.00
Kh 0.85
% = 0.00256KhKuKdV 22.43 PSF
P = qh[(GCpr)-(GCp,)] SEE CHART BELOW
GCp, +/-0.18
PRESSURE NORMAL TO SURFACE
N-S (LOAD CASE A)
SURFACE#• GC t p (LBS)
1 0.40 4.93
2 -0.69 -19.51
3 -0.37 -12.34
4 -0.29 -10.54
5
6
l E 0.61 9.64
2E -1.07 -28.04
3E -0.53 -15.92
4E -0.43 -13.68
SE
GE
TOTAL HORIZONTAL PRESSURE ON SURFACE
C
3
E-W (LOAD CASE B)
GC t p (LBS)
-0.45 -14.13
-0.69 -19.51
-0.37 -12.34
-0.45 -14.13
0.40 4.93
-0.29 -10.54
-0.48 -14.80
-1.07 -28.04
-0.53 -15.92
-0.48 -14.80
0.61 9.64
-0.43 -13.68
DIMENSIONS
LENGTH (L)
WIDTH(W)
ROOF HEIGHT
2ND STORY HT. [WALLS : FRAMING)
1ST STORY HT. [WALLS: FRAMING)
6.00'
8.00'
12.0'
13.0'
0.75'
0.50'
l l~· ~
W=l3.0' -~ .,,,. ____________ _
• SEE ASCE 7-10 FIGURE 28.4-1 FOR SURFACE
SURFACE AREA N-S (LOAD CASE A) E-W (LOAD CASE B)
SURFACE#• (Fr) p NORMAL TO SURFACE pHORIZ. COMPONENT p NORMAL TO SURFACE pHORIZ COMPONENT
1 92 0.451 0.451 -1.293 0
2 39 -0.761 0 -0.761 0
3 39 -0.481 0 -0.481 0
4 92 -0.965 0.965 -1.293 0
5 153 0 0 0.752 0.752
6 153 0 0 -1.608 1.608
l E 92 0.882 0.882 -1.354 0
2E 39 -1.093 0 -1.093 0
3E 39 -0.621 0 -0.621 0
4E 92 -1.252 1.252 -1.354 0
SE 46 0 0 0.441 0.441
GE 46 0 0 -0.626 0.626
!= 3.550 K != 3.427 K
DESIGN WIND PRESSURE MIN.= 2.928 K MIN.= 3.172 K
N-S E-W
AREAvERT. PROJ. 183 SQFT 198 SQFT
p 19.40 PSF 17.29 PSF
VERTICAL DISCRIBUTION OF WIND PRESSURE
LEVEL N-S (LRFD) E-W (LRFD) N-S (ASD) E-W {ASD)
2ND STORY 73 PLF 65 PLF 44 PLF 39 PLF
lSTSTORY 146 PLF 130PLF 87 PLF 78 PLF
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
TYPE OF LATERAL BRACE
DESIGN METHODOLOGY
2ND STORY
NORTH-SOUTH
A
WOOD SHEAR WALL
6.5
2.5
4
0.025h
ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I
OFFSET MULTIPLIER -------~--------
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
p
1.0
1.0
3.31 PSF
3.31 PSF
AREA
210 SQFT
TRIB. AREA
MULTIPLIER
0.5
TRIB. AREA
105 SQFT
12 of 24
JENSEN ADU
24-013
4/26/2024
CONTRIBUTING FORCES FROM
DIAPHRAGM ON LEVEL BELOW
AREA
TRIBUTARY AREA
DIST. TO NEXT BRACE
LOAD APPLICATION HT.
LOAD
0.348 K
LEVEL ABOVE 1-------I= 0.348 K
WIND LOAD DISTANCE TO
SOURCE PRESSURE NEXT BRACE LOAD
LOAD FROM LEFT WORST CASE 44 PLF
LOAD FROM RIGHT WORST CASE 44 PLF 12' 0.262 K
LEVEL ABOVE
I= 0.262 K
SHEAR WALL
SEGMENT LENGTH 6'
SEGMENT HEIGHT 14.5'
ASPECT RATIO 2.4 : 1
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY 17%
SEISMIC LOAD TO SEGMENT 0.058 KLF
WIND LOAD TO SEGMENT 0.044 KLF
SHEAR WALL TYPE [REQUIRED : USED] 1 I 2
HOLDOWN
SEGMENT LENGTH 6'
SEGMENT HEIGHT 14.5' -
SEISMIC LOAD TO SEGMENT 0.348 K
WIND LOAD TO SEGMENT 0.262 K
UNIFORM DEAD LOAD 0.261 KLF
~ '-j'-,-:==1 CONCENTRATED DEAD LOAD 1 (K) [LOAD : LOCATION] -·-, __ ,~1·~ CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION] , __ ----1--~~ ,_ -, __
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION] ' -I I I CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT) l I ' i ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT] 0.486 0.486 I I
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHT] ,
ASD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT) 0.173 0.173 I I I I
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT) I
I __ ,_
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT) 0.658 0.658
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT] i ~ ~--LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT) 0.371 0.371 I
REQUIRED HOLDOWN TYPE [LEFT : RIGHT] 10 1 I . I I I
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 1.200 K I I
1.055 K
I
i
I
I
COASTLINE
ENGINEERING
13 of 24
JENSEN ADU
24-013
4/26/2024
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
2ND STORY
NORTH-SOUTH
C
TYPE OF LATERAL BRACE FORCE-TRANSFER SHEAR WALL
6.5
2.5
4
0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I OFFSET MULTIPLIER
SEISMIC LOAD
p pF•
DIAPHRAGM 1.0 3.31 PSF
CANTILEVERED DIAPH. 1.0 3.31 PSF
W IND LOAD
SOURCE PRESSURE
LOAD FROM LEFT WORST CASE 44 PLF
LOAD FROM RIGHT WORST CASE 44 PLF
SHEAR WALL
TYPE OF OPENING
OVERALL ASPECT RATIO
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
MAXIMUM SEISMIC LOAD
MAXIMUM WIND LOAD
HEADER STRAP LOAD (K) [SEISMIC : WIND]
Sill STRAP LOAD (K) [SEISMIC: WIND)
SHEAR WALL TYPE [REQUIRED : USED]
HOLDOWN
OVERALL WALL LENGTH
OVERALL WALL HEIGHT
SEISMIC LOAD TO WALL
WIND LOAD TO WALL
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K] [LOAD : LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL WIND UPLIFT (K) [LEFT : RIGHTI
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHTI
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHTI
REQUIRED HOLDOWN TYPE [LEFT: RIGHT]
AREA
210 SQFT
DISTANCE TO
NEXT BRACE
12'
LEVEL ABOVE
!=
WINDOW
0.9: 1
0%
0.107 KLF
0.081 KLF
0.134 1 0.101
0.089 0.067
1 I 2
6.5'
6'
0.348 K
0.262 K
0.108 KLF
~
I I
o.158 I o.158
o.033 I 0.033
0.210 I 0.210
0.092 1 0.092
10 1 10
TRIS. AREA
MULTIPLIER
0.5
LOAD
0.262 K
0.262 K
VERTICAL LOAD AT EACH END OF SHEAR WALL (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.458 K
0.403 K
TRIS. AREA
105 SQFT
LEVEL ABOVE
!=
2'
;...
-
;..,
---
;.,,
CONTRIBUTING FORCES FROM
DIAPHRAGM ON LEVEL BELOW
AREA
TRIBUTARY AREA
DIST. TO NEXT BRACE
LOAD APPLICATION HT.
LOAD
0.348 K
0.348 K
DIMENSIONS
2.5' 2'
I
OPEN
I I
TOTAL LENGTH = 6.5'
INDIVIDUAL PIER ASPECT RATIOS
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
LEFT RIGHT
PIER PIER
1.0: 1 1.0: 1 °" 0%
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL 2ND STORY
DIRECTION EAST-WEST
GRID LINE 1
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R ~5
Oo _________ 2.5
Cd 4
0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE
OFFSET M ULTIPLIER
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
I
p pF4
1.0 3.31 PSF
1.0 3.31 PSF
SOURCE PRESSURE
WORST CASE 39 PLF
WORST CASE 39 PLF
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED : USED]
HOLDOWN
SEGMENT LENGTH
SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD : LOCATION)
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION)
CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION)
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT)
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT)
ASD -WIND UPLIFT FROM ABOVE (K) (LEFT : RIGHT)
ASD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT)
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT)
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT)
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT)
LRFD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT)
REQUIRED HOLDOWN TYPE [LEFT : RIGHT)
AREA
210 SQFT
DISTANCE TO
NEXT BRACE
13'
LEVEL ABOVE
12'
6'
0.5: 1
0%
l=
0.029 KLF
0.021 KLF
1 1
12'
6'
0.348 K
0.253 K
0.209 KLF
,_ --
--
-
i
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.253 K
0.253 K
·-
·-
-
I~~~ ·-
,.-
_,_
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.248 K I I
0.211 K
TRIB. AREA
105 SQFT
LEVEL ABOVE
l=
--
,_ ,~
,-.
I
14 of 24
JENSEN ADU
24-013
4/26/2024
CONTRIBUTING FORCES FROM
DIAPHRAGM ON LEVEL BELOW
AREA
TRIBUTARY AREA
DIST. TO NEXT BRACE
LOAD APPLICATION HT.
LOAD
0.348 K
0.348 K
~,~ =I -,-
,~
-,~ I
I
I I
I -,_
--,~
I
I I
I
-,~
I
I
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL 2ND STORY
DIRECTION EAST-WEST
GRID LINE 3
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R U
Oo _________ 2.5
Cd 4
0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
OFFSET M ULTIPLIER
GRID LINE I
---------------
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
p
1.0
1.0
SOURCE
WORST CASE
WORST CASE
3.31 PSF
3.31 PSF
PRESSURE
39 PLF
39 PLF
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGM ENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED : USED)
HOLDOWN
SEGMENT LENGTH -SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION)
CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT)
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT]
REQUIRED HOLDOWN TYPE [LEFT : RIGHTI
AREA
210 SQFT
DISTANCE TO
NEXT BRACE
13'
LEVEL ABOVE
l=
8'
6'
0.8: 1
0%
0.043 KLF
0.032 KLF
1 I 2
8'
6'
0.348 K
0.253 K
0.209 KLF
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.253 K
0.253 K
,--
--
,---1'---·-
-I .
-
I
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.372 K I I
0.316 K
TRIB. AREA
105 SQFT
LEVEL ABOVE
l =
--
-,-
-,~
I
I -
I I
I
15 of 24
JENSEN ADU
24-013
4/26/2024
CONTRIBUTING FORCES FROM
DIAPHRAGM ON LEVEL BELOW
AREA
TRIBUTARY AREA
DIST. TO NEXT BRACE
LOAD APPLICATION HT.
LOAD
0.348 K
1------0.348 K
-
-,_ -,,-
_,_ ~ ·-i
I -
I
I I
!
I
I I
I
I
I
I
---
I
I
I
:
,'
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
1ST STORY
NORTH-SOUTH
A (1-2)
TYPE OF LATERAL BRACE WOOD SHEAR WALL
DESIGN METHODOLOGY
6.5
2.5
4
0.025h
ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I
OFFSET MULTIPLIER
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
p
1.0
1.0
SOURCE
WORST CASE
WORST CASE
3.62 PSF
3.62 PSF
PRESSURE
87 PLF
87 PLF
REDUCTION IS SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED : USED]
HOLDOWN
SEGMENT LENGTH
SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (Kl [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 4 (K) [LOAD : LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHTI
ASD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT]
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD -WIND UPLIFT FROM ABOVE (Kl (LEFT: RIGHT]
LRFD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT]
REQUIRED HOLDOWN TYPE [LEFT : RIGHT]
AREA
80 SQFT
DISTANCE TO
NEXT BRACE
12'
LEVEL ABOVE
I=
3.5'
8'
2.3: 1
13%
0.041 KLF
0.150 KLF
1 I 2
3.5'
8'
0.145 K
0.524 K
0.144 KLF
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.524 K
0.524 K
,~ -
-,-
,--
·---·-
0.230 0.230
i
1.156 1.156 I
0.316 0.316
1.955 1.955
1 1
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
I 0.472 K I I 1.996 K
SEISMIC LOAD (WITHOUT p)
WIND LOAD
TRIB. AREA
40 SQFT
LEVEL ABOVE
I =
-,--~ ,~
---
LOAD
0.145 K
r-------0.145 K
-·-
I
~ ,_
--
~ --~
I
I
I
I
-
l ,~
I I-
' I
I
I
16 of 24
JENSEN ADU
24-013
4/26/2024
l I
-
-
I
I
I
i
,,---------;,,
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
1ST STORY
NORTH-SOUTH
A (3-4)
TYPE OF LATERAL BRACE FORCE-TRANSFER SHEAR WALL
DESIGN METHODOLOGY
6.5
2.5
4
0.025h
ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
OFFSET MULTIPLIER
GRID LINE I
----~~----------
SEISMIC LOAD
p
DIAPHRAGM
CANTILEVERED DIAPH.
1.0
1.0
3.62 PSF
3.62 PSF
WIND LOAD
SOURCE PRESSURE
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
TYPE OF OPENING
OVERALL ASPECT RA TIO
WORST CASE 87 PLF
WORST CASE 87 PLF
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
MAXIMUM SEISMIC LOAD
MAXIMUM WIND LOAD
HEADER STRAP LOAD (K) [SEISMIC: WIND]
SILL STRAP LOAD (K) [SEISMIC: WIND]
SHEAR WALL TYPE [REQUIRED: USED]
HOLDOWN
OVERALL WALL LENGTH
OVERALL WALL HEIGHT
SEISMIC LOAD TO WALL
WIND LOAD TO WALL
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD: LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHn
ASD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT]
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT)
LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT]
REQUIRED HOLDOWN TYPE [LEFT : RIGHT]
·-
AREA
170 SQFT
DISTANCE TO
NEXT BRACE
8'
LEVEL ABOVE
I=
WINDOW
0.8: 1
0%
0.073 KLF
0.083 KLF
0.220 I 0.2SO
0.154 0.175
1 I 2
10.5'
8'
0.307 K
0.349 K
0.212 KLF
!
I
I
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.349 K
0.349 K
VERTICAL LOAD AT EACH END OF SHEAR WALL (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.335 K
0.443 K
TRIB. AREA LOAD
85 SQFT 0.307 K
LEVEL ABOVE ------I= 0.307 K
DIMENSIONS
2' 6'
OPEN
TOTAL LENGTH = 10.5'
INDIVIDUAL PIER ASPECT RATIOS
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
2.5'
17 of 24
JENSEN ADU
24-013
4/26/2024
00
,-:x: I,!) w :x: _,
<I: ti ,-
LEFT RIGHT
PIER PIER
2.0: 1 1.6 : 1
0% 0%
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL 1ST STORY
DIRECTION NORTH-SOUTH
GRID LINE B
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R U
0 0 _________ 2.5
Cd 4
63 0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
OFFSET MULTIPLIER
GRID LINE I
----------------
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
p pF,
1.0 3.62 PSF
1.0 3.62 PSF
SOURCE PRESSURE
WORST CASE 87 PLF
WORST CASE 87 PLF
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED: USED]
HOLDOWN
SEGMENT LENGTH
SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION)
CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD-TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT)
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHTI
ASD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT]
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHTI
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT)
REQUIRED HOLDOWN TYPE [LEFT: RIGHT]
AREA
170 SQFT
DISTANCE TO
NEXT BRACE
8'
LEVEL ABOVE
17'
8'
0.5: 1
0%
I=
0.018 KLF
0.021 KLF
1 1 1
17'
8'
0.307 K
0.349 K
0.212 KLF
_,_
-
l:
--
I
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.349 K
0.349 K
·--
~-~,~
i
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.207 K I I
0.274 K
TRIB. AREA
85 SQFT
LEVEL ABOVE
I=
-
-~
-,-
-,~
i
LOAD
0.307 K
0.307 K
-·-
-
~-,~~ --
I
I
I
I
I
1-,_
i--
,_
I
I
I
I
18 of 24
JENSEN ADU
24-013
4/26/2024
I
I
1
•
I
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL 1ST STORY
DIRECTION NORTH-SOUTH
GRID LINE C
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R U
Oo _________ 2.5
~ 4
63 0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I
OFFSET MULTIPLIER -----------~~-~
C
SEISMIC LOAD TRIB. AREA
p pF4 AREA MULTIPLIER TRIB. AREA
DIAPHRAGM 1.0 3.62 PSF 80SQFT 0.5 40SQFT
CANTILEVERED DIAPH. 1.0 3.62 PSF
LEVEL ABOVE
I=
WIND LOAD DISTANCE TO
SOURCE PRESSURE NEXT BRACE LOAD
LOAD FROM LEFT WORST CASE 87 PLF 12' 0.524 K
LOAD FROM RIGHT WORST CASE 87 PLF
LEVEL ABOVE 0.262 K
I= 0.786 K
SHEAR WALL
SEGMENT LENGTH 6'
SEGMENT HEIGHT 8'
ASPECT RATIO 1.3 : 1
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY 0%
SEISMIC LOAD TO SEGMENT 0.082 KLF
WIND LOAD TO SEGMENT 0.131 KLF
SHEAR WALL TYPE [REQUIRED: USED) 1 I 2
HOLDOWN
SEGMENT LENGTH 6' -SEGMENT HEIGHT 8' --SEISMIC LOAD TO SEGM ENT 0.492 K -WIND LOAD TO SEGMENT 0.786 K
UNIFORM DEAD LOAD 0.144 KLF
j ~,~ -~ CONCENTRATED DEAD LOAD 1 (K) [LOAD: LOCATION) I -,_ -·-CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION] --, ___ ----CONCENTRATED DEAD LOAD 3 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION)
ASD • SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT] 0.158 0.158
ASD • TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT] 0.630 0.630
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHTI 0.033 I 0.033
ASD • TOTAL WIND UPLIFT (K) [LEFT: RIGHT] 0.868 0.868
LRFD • SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT] 0.210 0.210
LRFD -TOTAL SEISMIC UPLIFT {K) [LEFT: RIGHT] 0.865 0.865
LRFD • WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHTI o.092 I o.092
LRFD • TOTAL WIND UPLIFT (K) [LEFT: RIGHT] 1.529 1.529
REQUIRED HOLDOWN TYPE [LEFT : RIGHT] 1 I 1
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD {WITHOUT p) I 0.938 K I I
1.746 K WIND LOAD
LOAD
0.145 K
0.348 K
0.492 K
'----
,-··-, __
I
I
I
·-I I
I
I I
I I
19 of 24
JENSEN ADU
24-013
4/26/2024
:=-~I
-,_
_,_
I
!
!
COASTLINE
ENGINEERING ,,
LATERAL BRACING ANALYSIS
LEVEL 1ST STORY
DIRECTION EAST-WEST
GRID LINE 1
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R ~5
Oo _________ 2.5
Cd 4
6a 0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I
OFFSET MULTIPLIER
1
SEISMIC LOAD TRIB. AREA
p pF4 AREA MULTIPLIER TRIB. AREA
DIAPHRAGM 1.0 3.62 PSF 80SQFT 0.5 40SQFT
CANTILEVERED DIAPH. 1.0 3.62 PSF
LEVEL ABOVE
r=
WIND LOAD DISTANCE TO
SOURCE PRESSURE NEXT BRACE LOAD
LOAD FROM LEFT WORST CASE 78 PLF 7' 0.272 K
LOAD FROM RIGHT WORST CASE 78 PLF
LEVEL ABOVE 0.253 K
r= 0.525 K
SHEAR WALL
SEGMENT LENGTH 12'
SEGMENT HEIGHT 8'
ASPECT RATIO 0.7: 1
REDUCTION IS SEISMIC SHEAR PANEL CAPACITY 0%
SEISMIC LOAD TO SEGMENT 0.041 KLF
WIND LOAD TO SEGMENT 0.044 KLF
SHEAR WALL TYPE [REQUIRED: USED) 1 I 1
HOLDOWN
SEGMENT LENGTH 12'
SEGMENT HEIGHT 8' ·-SEISMIC LOAD TO SEGMENT 0.492 K
WIND LOAD TO SEGMENT 0.525 K
UNIFORM DEAD LOAD 0.190 KLF --CONCENTRATED DEAD LOAD 1 (K) [LOAD : LOCATION) --~
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION)
~
, ___ --·-CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION) -·-CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION)
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT)
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT) -
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT) -
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT)
LRFD-WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT)
LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT) -
REQUIRED HOLDOWN TYPE [LEFT: RIGHT) I -
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p) I 0.469 K I I
0.583 K WIND LOAD
LOAD
0.145 K
0.348 K
0.492 K
I~ ,-•,·-
I•-------------., ·-
I
I
I .
20 of 24
JENSEN ADU
24-013
4/26/2024
I
!
I
·--===
-
I I
I
I '
I
COASTLINE
ENGI N EERING
LATERAL BRACING ANALYSIS
LEVEL 1ST STORY
DIRECTION EAST-WEST
GRID LINE 2
TYPE OF LATERAL BRACE WOOD SHEAR WALL
R 6.5
Oo _________ 2.5
~ 4
63 0.025h
DESIGN METHODOLOGY ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
OFFSET MULTIPLIER
GRID LINE I
--~~~-~-~-~~-----
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
p
1.0
1.0
SOURCE
WORST CASE
WORST CASE
3.62 PSF
3.62 PSF
PRESSURE
78 PLF
78 PLF
REDUCTION IS SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED: USED]
HOLDOWN
SEGMENT LENGTH
SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 4 (K) [LOAD: LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD -WIND UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
ASD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT]
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD -WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD -TOTAL WIND UPLIFT (K) [LEFT: RIGHT]
REQUIRED HOLDOWN TYPE [LEFT : RIGHT]
AREA
80 SQFT
DISTANCE TO
NEXT BRACE
7'
5'
LEVEL ABOVE
3.25'
8'
2.5: 1
19%
I =
0.045 KLF
0.144 KLF
1 1 2
3.25'
8'
0.145 K
0.467 K
0.114 KLF
[
0.297 0.297
1.157 1.157
0.415 0.415
1.949 1.949
1 I 1
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.272 K
0.194 K
0.467 K
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD (WITHOUT p)
WIND LOAD I 0.509 K I I
1.915 K
TRIB. AREA
40 SQFT
LEVEL ABOVE
I=
LOAD
0.145 K
1------0.145 K
21 of 24
JENSEN ADU
24-013
4/26/2024
COASTLI N E
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
1ST STORY
EAST-WEST
3
TYPE OF LATERAL BRACE WOOD SHEAR WALL
DESIGN METHODOLOGY
6.5
2.5
4
0.025h
ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
GRID LINE I
OFFSET MULTIPLIER
3
SEISMIC LOAD
p pF4
DIAPHRAGM 1.0 3.62 PSF
CANTILEVERED DIAPH. 1.0 3.62 PSF
WIND LOAD
SOURCE PRESSURE
LOAD FROM LEFT WORST CASE 78 PLF
LOAD FROM RIGHT WORST CASE 78 PLF
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED : USED]
HOLDOWN
SEGMENT LENGTH ·-SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGM ENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD : LOCATION]
AREA
170 SQFT
DISTANCE TO
NEXT BRACE
18'
7'
LEVEL ABOVE
r=
4.25'
8'
1.9:1
0%
0.154 KLF
0.288 KLF
2 I 2
4.25'
8'
0.655 K
1.225 K
0.144 KLF
TRIS. AREA
MULTIPLIER TRIS. AREA
0.5 85 SQFT
LEVEL ABOVE
r=
LOAD
0.700 K
0.272 K
0.253 K
1.225 K
,_ ' -
-·--·-
,_ ,_ -,_
-,~--,-CONCENTRATED DEAD LOAD 3 (K) [LOAD: LOCATION) -, ___ ·-
-,-
CONCENTRATED DEAD LOAD 4 (K) (LOAD : LOCATION]
ASD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT] 1.176 1.176
ASD -WIND UPLIFT FROM ABOVE (K) (LEFT: RIGHn
ASD -TOTAL WIND UPLIFT (K) [LEFT : RIGHT] 2.303 2.303
LRFD -SEISMIC UPLIFT FROM ABOVE (K) [LEFT : RIGHT]
LRFD -TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT] 1.666 1.666
LRFD -WIND UPLIFT FROM ABOVE (K) (LEFT: RIGHT]
LRFD -TOTAL WIND UPLIFT (K) (LEFT : RIGHT] 3.872 3.872
REQUIRED HOLDOWN TYPE (LEFT: RIGHT] 1 1 I
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
I 1.762K I I
3.844 K
SEISMIC LOAD (WITHOUT p)
WIND LOAD
LOAD
0.307 K
0.348 K
0.655 K
I I~
I
I
I I i
I
I
22 of 24
JENSEN ADU
24-013
4/26/2024
I
I
-1
-·-
-,~
~~--
I
I
I
I
COASTLINE
ENGINEERING
LATERAL BRACING ANALYSIS
LEVEL
DIRECTION
GRID LINE
1ST STORY
EAST-WEST
4
TYPE OF LATERAL BRACE WOOD SHEAR WALL
DESIGN METHODOLOGY
6.5
2.5
4
0.025h
ASD
CONTRIBUTING FORCES FROM LEVEL ABOVE
OFFSET MULTIPLIER
GRID LINE I
~~-~-----------
SEISMIC LOAD
DIAPHRAGM
CANTILEVERED DIAPH.
WIND LOAD
LOAD FROM LEFT
LOAD FROM RIGHT
SHEAR WALL
SEGMENT LENGTH
SEGMENT HEIGHT
ASPECT RATIO
p
1.0
1.0
SOURCE
WORST CASE
WORST CASE
3.62 PSF
3.62 PSF
PRESSURE
78 PLF
78 PLF
REDUCTION IN SEISMIC SHEAR PANEL CAPACITY
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
SHEAR WALL TYPE [REQUIRED : USED]
HOLDOWN
SEGMENT LENGTH
SEGMENT HEIGHT
SEISMIC LOAD TO SEGMENT
WIND LOAD TO SEGMENT
UNIFORM DEAD LOAD
CONCENTRATED DEAD LOAD 1 {K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 2 (K) [LOAD: LOCATION]
CONCENTRATED DEAD LOAD 3 (K) [LOAD : LOCATION]
CONCENTRATED DEAD LOAD 4 (K) [LOAD : LOCATION]
ASD • SEISMIC UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
ASD • TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
ASD • WIND UPLIFT FROM ABOVE {K) [LEFT: RIGHT]
ASD • TOTAL WIND UPLIFT (K) [LEFT : RIGHT]
LRFD • SEISMIC UPLIFT FROM ABOVE {K) [LEFT : RIGHT]
LRFD • TOTAL SEISMIC UPLIFT (K) [LEFT: RIGHT]
LRFD • WIND UPLIFT FROM ABOVE (K) [LEFT: RIGHT]
LRFD • TOTAL WIND UPLIFT (K) [LEFT : RIGHT]
REQUIRED HOLDOWN TYPE [LEFT: RIGHT]
AREA
170 SQFT
DISTANCE TO
NEXT BRACE
18'
LEVEL ABOVE
l=
3.25'
9'
2.8 : 1
28%
0.095 KLF
0.215 KLF
1 I
3.25'
9'
0.307 K
0.700 K
2
0.162 KLF
0.806 0.806
1.984 1.984
1.138 1.138
3.337 3.337
1 1
TRIB. AREA
MULTIPLIER
0.5
LOAD
0.700 K
0.700 K
VERTICAL LOAD AT EACH END OF SHEAR WALLS (FROM UNFACTORED E/W ONLY)
SEISMIC LOAD {WITHOUT p)
WIND LOAD I 1.216K I I
3.231 K
TRIB. AREA
85 SQFT
LEVEL ABOVE
l =
LOAD
0.307 K
1------0.307 K
23 of 24
JENSEN ADU
24-013
4/26/2024
I
·:
i
I
I
I
,,-,,,
COASTLINE
ENGINEERING
SOIL PROPERTIES
BEARING PRESSURE
INCREASE FOR WIDTH
INCREASE FOR DEPTH
MAXIMUM BEARING PRESSURE
2500 PSF
2S00 PSF
FOUNDATION ANALYSIS
MINIMUM FOOTING DIMENSIONS
NEW
CONTINUOUS FTG. WIDTH 15"
PAD FOOTING WIDTH 24"
FOOTING DEPTH 18"
FOOTING REINFORCEMENT PER PLAN
CONTINUOUS FOOTING DESIGN
GRID LINE 1
LOAD TYPE
TRIS. LENGTH
D
Lr
L
RLl
7.5
0.101
0.1S0
MAXIMUM FACTORED LOAD
REQUIRED FOOTING WIDTH
FOOTING DEPTH USED
PAD FOOTING DESIGN
Fll EWl
3.25 14.5
0.046 0.261
0.130
0.618 KLF (D+0.75L+0.75Lr)
15"
18"
EXISTING
12"
24"
12"
I
24 of 24
JENSEN ADU
24-013
4/26/2024
TOTAL
0.408 KLF
0.1S0 KLF
0.130 KLF
--i
I
To:
Subject:
Mr. Jensen,
SB Consultants, Inc.
Geotechnical-Concrete-Forensic Engineering Services
619-922-3302
Jerett Jensen
R--:-r::~VEO
MA'< '2 b 2024
CARLSBAD
~3:gl~G DIVISION
Proposal for Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Job No. 221119
March 14, 2024
In accordance with your request, we have conducted a geotechnical investigation for the
proposed development for the property located at 2802 Atadero Court, Carlsbad, CA. The
scope of work performed for this investigation was as follows:
• Review of background geologic maps and other reports,
• Subsurface exploration,
• Laborat ory soil testing,
• Geotechnical analysis and preparation of this report sum marizing our findings and
conclusions and presenting recommendations for design and construction of building
foundations and floor slabs and other geotechnical parameters, as well as
recommendations for site grading and other geotechnical aspect s of construction.
SITE DESCRIPTION
The site location is shown on the attached Vicinity Map, Figure 1. For purposes of this report,
the front of the property faces south towards Atadero Court. The site is an irregular-shaped
parcel with an area of approximately 0.22 acres. The property is bordered by other residential
properties to the north, east, Los Pi nos Circle to the west, and Atadero Court to the south.
The property to the east is near the same building pad elevation, and Atadero Court is a few
feet lower. The property to the north is 16 feet higher, w ith the elevation change accomplished
by a terraced slope and a 5-feet high concrete masonry unit (CMU) wall at t he toe of the slope.
Vegetation consists of shrubs, turf, and mature palms.
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
PROPOSED CONSTRUCTION AND SCOPE OF WORK
Page2
Job No. 240305
March 14, 2024
Based on our review of the preliminary plans by Specialty Home Improvement and our
discussions with you, the proposed building will co nsist of a new one-to two-story accessory
dwelling unit (ADU}. The AD U will be situated in the backyard below the slope and near the
northwest corner of the flat portion of the pad. The ADU will be approximately 300 sft in plan
area. Figure 2 provides a layout of the project.
The ADU will be supported on continuous and isolated pad footings with slab-on-grade floors.
The structure will be wood-framed.
Site grading will consist primarily of removal of existing concrete and excavation for the
perimeter footings and removal and recompaction of near-surface soils, to a maximum depth of
approximately 1 foot. The existing CMU retaining wall at the base of the slope will remain.
SUBSURFACE EXPLORATION
The subsurface exploration was performed on March 5, 2024, and consisted of hand excavating
3 borings to a maximum depth of 6 feet where practical refusal was encountered on dense,
sandstone bedrock. The approximate locations of the excavations are shown on Figure 2. The
excavations were logged and sampled by a licensed engineer. The logs of the excavations are
presented on Figure 3.
LABORATORY SOIL TESTING
Laboratory testing was performed on soil sa mples obtained from the borings and consisted of
in-place moisture content test s. The results of the tests are presented on the boring logs.
SUBSURFACE FINDINGS
The site is underlain by a thin layer of fill, in turn underlain by sedimentary sa ndstone bedrock.
These materials are presented herein in order of increasing age.
Fill (Qf):
Fill soils were encountered to a maximum depth of approximately 2 feet. The 2 feet of fill was
encountered at Boring B-2 that was extended through a raised planter adjacent to the
SBCI
SBURNSRCE(gGMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page 3
Job No. 240305
March 14, 2024
proposed ADU. Fill soils were encountered to a maximum depth of 0.5 feet in the area of the
proposed ADU. The fill consisted of gray and orange-brown, damp, loose, silty sand with roots.
The fill ha s a very low expansion index (El<21) based on visua l observations and experience
with similar materials in the area. Table 1 provides a breakdown of expansion classifications.
TABLE 1
EXPANSION CLASSIFICATION BASED ON EXPANSION INDEX
ASTM D 4829
Expansion Index (El) Expansion CBC Expansion
Classification Classification
0-20 Very Low Non-Expansive
21-50 Low
51-90 Medium
91 -130 High Expansive
Greater Than 130 Very High
The fill is not suited for the support of the proposed development but can be reused as
compacted, engineered fill. The fill will require removal and recompaction in the area of the
ADU.
Santiago Formation (Tsa):
Natural sedimentary bedrock designated as Santiago Formation was encountered below the fill.
As observed, the natural soils consisted of light brown and orange-brown, damp, dense
sandstone.
The bedrock has a very low expansion index (El<21) based on visual observation and experience
with similar soils in the area.
GEOLOGY
The subject site is located within the Peninsular Ranges Geomorphic Province of California. This
province is generally comprised of northwest-southeast trending structural blocks and ext ends
SBCI
SBURNSRCF.@;GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page4
Job No. 240305
March 14, 2024
930 miles from Baja California to Southern California. Within San Diego County, the coastal
portion of the province varies from upper Cretaceous-aged to Tertiary-aged (1.8 million to 65
million years) bedrock units that have been deposited within a northwest-trending basin known
as the San Diego Embayment.
Within the San Diego coastal margin, marine terrace deposits associated with a combination of
sea-level changes and geologic uplift blanket large portions of the area. These deposits
generally consist of marine, beach, and lagoonal facies and range from early to mid-
Quaternary-aged (45,000 to 1.5 million years) and are designated in geologic literature as
Paralic Deposits.
According to geologic literature, the site is underlain by middle Eocene-aged sedimentary
bedrock designated as Santiago Formation.
SEISMICITY
No known active faults traverse the property according to our review of published and
unpublished literature.
It should be noted that much of Southern California, including the San Diego County area, is
characterized by a series of Quaternary-age fault zones, which typically consist of several
individual, en echelon faults that generally strike in a northerly to northwesterly direction.
Some of these fault zones (and the individual faults within the zones) are classified as active
w hile others are classified as only potentially active, according to the criteria of the California
Division of Mines and Geology (currently California Geological Survey; CGS, 2018). Active fault
zones are those that have shown conclusive evidence of faulting during the Holocene Epoch
(the most recent 11,700 years), while potentially active fault zones have demonstrated
movement during the Pleistocene Epoch (11,700 to 2.6 million years before the present) but no
movement during Holocene time.
Rupturing of the ground is not likely due to the absence of known active fault traces within the
project limits. Due to the generally active seismicity of Southern California, however, the
possibility for ground lurching or rupture cannot be completely ruled out.
SBCI
SBURNSRCE(gGMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
LANDSLIDE POTENTIAL AND SLOPE STABILITY
Page 5
Job No. 240305
March 14, 2024
A review of geologic hazards maps indicates there are no known, deep, or suspected ancient
landslides located on the site. Features typical of landsliding were not observed on the
property. Indications of clay beds were not observed in our borings or on the slope face. The
proposed development will not decrease the existing slope stability. Due to the competent
nature of the underlying sedimentary bedrock, site observat ions, and soils conditions
encountered, landslide haza rds do not appear to present a significant risk to the proposed
project.
GROUNDWATER
Groundwater was not encountered and is anticipated to be more than 40 feet below existing
grade.
A perched groundwater condition should be anticipated near the contact between the fill and
natural sa ndstone during extended rainfall and/or heavy irrigation.
CORROSIVITY TO CONCRETE AND METAL
Corrosion testing was not performed on the on-site soils.
Based on our experi ence, onsite soils should be considered as having negligible su lfate content
with respect to exposure to concrete. The onsite soils are also considered corrosive to buried
metals.
SBCI is not a corrosion consultant and does not provide recommendations related to corrosion.
Laboratory testing should be performed at the completion of grading by the proj ect corrosion
engineer to evaluate the corrosion charact eristics of the graded soils.
SEISMIC DESIGN VALUES
Seismic design values are presented on Figure 4.
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
CONCLUSIONS AND RECOMMENDATIONS
Page6
Job No. 240305
March 14, 2024
The site is suitable for construction of the proposed development, provided the following
recommendations are incorporated into the design and construction of the project.
1. GRADING AND EARTHWORK
• Site Clearing
All debris, concrete, and organic materials, including roots and root balls, should be removed
from the site.
• Removal of Loose Surface Soils
For the ADU and surrounding exterior concrete slabs and to a distance of at least 4 feet outside
these improvement limits (where space permits}, existing fill soils shall be removed. Based on
our investigation, removals are anticipated to extend to a depth of 0.5 to 1 foot below existing
grade. Soils disturbed as part of the demolition process and fill soils associated with existing
utility trenches shall be removed and recompacted.
Actual removal depths may be greater based on conditions encountered and shall be confirmed
during grading by a representative of SBCI.
• Excavation and Soil Characteristics
Excavation of the fill and natural soils should be possible w ith moderate effort using
conventional heavy-duty equipment and hand tools.
• Fill Suitability
The natural soils may be reused as compacted fill, provided they are free of debris, concrete,
organic materials, clay, and rocks or cobbles over 6 inches in dimension.
Any import fill soils should be predominantly sandy with a very low expansion index (El less
than 21) and approved by the engineering firm providing geotechnical services.
SBCI
SBURNSRCf'.€GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
• Temporary Excavations and Slopes
Page7
Job No. 240305
March 14, 2024
Temporary cut slopes and excavations may be excavated vertically to a max imum height of 4
feet. Temporary cut slopes and excavations great er than 4 feet in height should be inclined no
steeper than 3/4:1 {horizontal to vertica l}.
Th e contractor shall protect and support existing improvements.
• Compaction and Method of Filling
The exposed subgrade soils at the bottom of the soil removal areas shall be sca rified to a depth
of 6 to 8 inches, moisture conditioned slightly above the soils' optimum moisture content, and
compacted to at least 90 perce nt relative compaction in the ADU and surrounding hardscape
areas.
Fill soils should be placed soils in 6-to 8-inch thick lifts, moisture co nditioned slightly above the
soils' optimum moisture content, and compacted by mechanical means to a minimum relative
compaction of 90 percent {per ASTM D1557).
Utility trench backfill should be compacted to at least 90 percent relative compaction.
Approximately 10 to 12 percent shrinkage resulting from recompacting the on-site soils is
anticipated but may be more.
All grading, fill placem ent, and compaction should be performed in accordance with the grading
requirements of the City of Carlsbad, CBC, and this report. Fill placement and compaction
should be observed and tested as necessary by the engineering firm providing geotechnical
services.
2. FOUNDATIONS
The recommended foundation design parameters and guidelines are considered minimums.
They do not preclude more restrictive criteria, which the governing agency or structural
engineer may require. The architect or structural engineer should evaluate the foundation
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page8
Job No. 240305
March 14, 2024
configurations and reinforcement requirements for structural loading, concrete shrinkage, and
temperature stress.
• Footing Type and Depth
The proposed structure may be supported on continuous and/or individual spread footings
bearing in dense, natural soils.
Footings for one-story structures shall extend a minimum of 15 inches below lowest adjacent
grade, or 6 inches into dense, natural sandstone, whichever is deeper.
Footings for two-story structures shall extend a minimum of 18 inches below lowest adjacent
grade or 6 inches into dense, natural sandstone, whichever is deeper.
Continuous footings shall have a minimum width of 15 inches. Individual footings shall have a
minimum width of 18 inches.
• Allowable Soil Bearing Pressure
Footings may be designed for an allowable, dead plus live load bearing pressure of 2,500 psf,
with a one-third increase for short-term, wind, or seismic loads.
• Footing Reinforcing
Minimum reinforcing of continuous footings should consist of four No. 4 rebars placed two at
the top of the footing and two at the bottom of the footing. Individual footings should be
reinforced with a grid of No. 4 rebars spaced 12 inches on centers (each way) and placed on
concrete blocks at the bottom of the footing. Reinforcing steel should have a minimum
concrete cover of 3 inches.
• Lateral Load Resistance
A passive soil resistance equal to an equivalent fluid pressure of 250 psf /ft may be used for
design.
The upper 6 inches should be omitted unless t he surface is finished with concrete.
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page9
Job No. 240305
March 14, 2024
A coefficient of friction between concrete and soil of 0.35 may also be used. If passive and
friction values are used together, the passive value should be reduced by one-third.
• Cleaning and Inspection of Footing Excavations
Footing depths should be verified by the engineering firm providing geotechnical services prior
to the placement of reinforcing steel.
Footing excavations should be thoroughly clea ned of loose soils prior to inspection and pouring
of concrete.
• Anticipated Footing Settlement
Anticipated total and differential settlements should be less than 1/2-inch.
It should be recognized that minor cracks normally occur in concrete slabs and foundations due
to shrinkage during curing and/or redistribution of stresses, and some cracks may be
anticipated. Such cracks are not necessarily an indication of excessive vertical movements.
3. CONCRETE SLABS
The recommended concrete slab parameters are considered minimums. They do not rule out
more restrictive requirements, which the governing agency or structural engineer may require.
The architect or structural engineer should evaluate the reinforcement requirements for
structural loading, concrete shrinkage, and temperature stress.
• Interior Floor Slabs
Unless otherwise specified by the project's structural engineer, interior floor slabs should be at
least 5 inches thick and reinforced with No. 3 rebars spaced at 18 inches on centers in two
directions and placed near the upper 1/3 of the slab.
Control joints, if necessary, shall be specified by the project structural engineer.
Interior floor slabs should be underlain by 2 inches of clean sand, over a 10-mil visqueen
moisture barrier, placed over a 4-inch layer of sub-rounded gravel. All visqueen products, laps,
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page 10
Job No. 240305
March 14, 2024
and splices should be in accordance with standard industry practices and CBC requirements. In
moisture-sensitive floor areas, 15-mil Stego Wrap is recommended.
To reduce permeability, floor slab concrete should have a minimum compressive strength of
3,000 psi and maximum water-cement ratio of 0.5. No special inspection of concrete is
required.
Following placement of concrete floor slabs, sufficient drying time must be allowed prior to
placement of floor coverings. Premature placement of floor coverings may result in
degradation of adhesive materials and loosening of t he finish floor materials. Prior to
installation, standardized testing (ca lcium ch loride test and/or relative humidity) can be
performed to determine if the slab moisture emissions are within the limits recommended by
the manufacturer of the specified floor-covering product.
Brittle finishes placed on the new slabs may crack. If tile is placed, slip sheets should be
considered in all floor tile areas to reduce the potential of slab cracks reflecting up through the
tile finishes.
• Exterior Concrete Slabs
Exterior concrete slabs shall be the sa me as recommended for interior concrete slabs but the
visqueen and gravel can be omitted. Crack control joint spacing should not exceed 10 feet in
any direction for both ext erior slabs and curbs. Control joints should be placed within 8 hours
of concrete placement.
4. DRAINAGE, LANDSCAPING, AND EROSION CONTROL
Surface water should not be allowed to pond next to the building or along the top of retaining
walls. Surface drainage shall not flow over the top of retaining walls. Finished grades should
slope and be maintained at a minimum of 2 percent away from the buildings, patios and
retaining walls for a minimum of 8 feet away from the structure where the water should be
captured by surface drains or directed to an approved outlet. Roof gutters and downspouts
connecting to solid outlet pipes are recommended for both buildings. Drainage water should
be discharged to an approved outlet.
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page 11
Job No. 240305
March 14, 2024
Solid-walled drainage pipes should be a minimum of 3 inches in diameter, schedule 40 or
better, and with all joints gl ued and taped.
Surface erosion on the slope can be reduced by proper irrigation and landscaping. In general,
we recommend drought tolerant, deep rooted plants. We defer to a qualified landscape
architect, however, in providing specific recommendations for the site.
In addition, appropriate erosion-control measures shall be taken at all times during
construction to prevent surface runoff waters from entering footing excavations, ponding on
finished building pad or pavement areas, or running uncontrolled over the tops of newly-
constructed cut or fill slopes. Appropriate Best Management Practice (BMP) erosion control
devices should be provided in accordance with loca l and federal governing agencies.
5. REVIEW OF BUILDING PLANS
Final building plans should be reviewed by SBCI to ensure that they conform with the
recommendations presented in this report. The recommendations presented in this report may
be amended based on the plan review.
6. ADDITIONAL TESTING
The finished grade soils should be tested for expa nsion index to confirm the ass umptions in this
report. The recommendations presented in this report may be amended based on the testing
results.
7. SAFETY
It should be noted that the contractor is solely responsible for the support of the existing
building and designing and constructing stable, temporary excavations and may need to shore,
slope, or bench the sides of trench excavations as required to maintain the stability of the
excavation sides where friable sands or loose soils are exposed. The contractor's "responsible
person," as defined in the OSHA Construction St andards for Excavations, 29 CFR, Part 1926,
should evaluate the soil exposed in the excavations as part of the contractor's safety process .
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page 12
Job No. 240305
March 14, 2024
In no case should slope height, slope inclination, or excavation depth, including utility trench
excavation depth, exceed those specified in loca l, state, and federal safety regulations. Actual
safe slope angles should be verified by the engineering consultant at the time of ex cavation.
LIMITATIONS
The recommendations and opinions expressed in this report reflect our best interpretation of
the project requirements based on an evaluation of the subsurface soil conditions encountered
at the subsurface exploration locations performed and on the assumption that the soil
conditions do not deviate appreciably from those encountered. It should be recognized that
the performance of the foundations may be influenced by undisclosed or unforeseen va ri ations
in the soil conditions that may occur in the intermediate and unexplored areas. Any unusual
conditions not covered in t his report that may be encount ered du ring site development should
be brought to the attention of the engineering firm providing geotechnical services so that
modifications ca n be made, if necessary.
This office should be advised of any changes in the project scope or proposed site grading so
that we may determine if the recommendations contained herein are appropriate. It should be
verified in writing if the recommendations are found to be appropriate for the propose d
changes, or our recommendations should be modified by a written addendum.
In t he performance of our professional services, we comply with that level of care and skill
ordinarily exercised by members of our profession currently practicing under similar conditions
and in the same locality. The cl ient recognizes that subsurface conditions may va ry from those
encountered at the locations w here our borings, surveys, and explorations are made and that
our data, interpretations, and recommendations are based solely on the information obtained
by SBCI. We will be responsible for those data, interpretations, an d recommendations but shall
not be responsible for the interpretations by others of the information developed. Th is report
provides no w arranty, either expressed or implied, conce rning future building performance.
Future damage from geotechnical or other causes is a possibility.
It is the responsibility of the stated client or their representatives to ensure that the
information and recommendations contained herein are brought to the attention of the
st ructural engineer and architect for the project and incorporated into the project's plans and
specifications. It is further their responsibilit y to take the necessary measures to ensure that
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
Page 13
Job No. 240305
March 14, 2024
the contractor and his subcontractors carry out such recommendations during construction.
This report should be considered valid for a period of two years and is subject to review and
possible changes following that time.
This opportunity to be of service is appreciated.
Respectfully submitted,
Scott C. Burns, PE
Principal Engineer
ATTACHMENTS
• Figure 1 -Site Location
• Figure 2 -Excavation Location Map
• Figure 3 -Excavation Logs B-1 through 8-3
• Figure 4 -Seismic Design Parameters
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
N
OSCALE
FIGURE 1
VICINITY MAP
Soi,jru Beoch
Del M:ll
SITE
LOCATION ,_,
,-c V,
::i ~
CJ)
(')
:ii
2802 Atadero Ct., Carlsbad, CA 92009
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Page 14
Job No. 240305
March 14, 2024
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
FIGURE 2
EXCAVATION LOCATION AND GEOLOGIC MAP
SCHEMATIC ONLY
LEGE D
Page 15
Job No. 240305
March 14, 2024
B-3 @ APPROXIMATE LOCATIO OF EXPLORATO RY BORI G
Q£'Tsa == FILL OYER SANTIAGO FORMATIO
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
FIGURE 3
LOGS OF EXCAVATIONS
B-1
Approx. elev.= 213' amsl
Depth (ft.) Description
0-0.5' Fill (Qf): Gray-brown, slightly moist, loose, silty sand
0.5-4'
Depth (ft.)
Santiago Formation (Tsa): Light gray and orange-brown, damp,
dense sandstone
Excavated and backfilled 03/05/24
No groundwater encountered
B-2
Approx. elev.= 211' amsl
Description
Page 16
Job No. 240305
March 14, 2024
MC
9.8%
10.3%
MC
0-2' Fill (Qf): Dark brown, damp, loose, silty sand with organics and roots 11.6%
2-6'
Depth (ft.)
0-0.5'
0.5-4'
Santiago Formation (Tsa): Light gray and orange-brown, damp,
dense sandstone
Excavated and backfilled 03/05/24
No groundwater encountered
B-3
Approx. elev.= 209' amsl
Description
Fill (Qf): Gray, damp, loose, silty sand
Santiago Formation (Tsa): Light gray and orange-brown, damp,
dense sandstone
Excavated and backfilled 03/05/24
No groundwater encountered
MC= Moisture Content
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
10.2%
MC
12.8%
11.2%
Limited Geotechnical Investigation
New Accessory Dwelling Unit
2802 Atadero Court
Carlsbad, CA 92009
FIGURE 4
Page 17
Job No. 240305
March 14, 2024
Site Coefficients and Spectral/Ground Response Acceleration
Parameters
LATTITUDE: 33.070467/ LONGITUDE: -117.251622
Risk Category II
Site Class "C" -Very Dense Soil, Soft Rock
ASCE 7-22 ST ANDA RD
ASCE
....... n-.-at."Cna
Seismic
Site Soil Clau: C -Very ee.-Sol aoo Soft Rod<
Results:
s..,
Sa,.
s.,,
0.5
1.22
0.52
0.81
0.35
Seiamic Design Category: 0
o•
o.
0
'
M-MCE,, Spee1nm
• S•(g)vsT(•)
Two--Period MCEftSpedrum
T l :
s.:
S,:
v..,
10
co
8
1.14
0.36
530
Muft>.Pencd Oeoogn Spea\.111
Two--Period Oe9gn Spedrum
,o
I , < e 1 e a, . ' 1 • ' S.(Q) vs T(•I S.(g)vs T(•)
MCG, Vertical Reaponoe Spedrum Design Vertical Rell)On9e Spedrum
Vertical grou,d moilondma '-not yet been made Verlk:el !lnuld motion data hlll not yet been made
--by VSGS. avatlable by USGS
SBCI
SBURNSRCE@GMAIL.COM
5215 La Jolla Hermosa Ave., La Jolla, CA 92037
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs 'M-iEN RAIN
IS EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING
RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES 'M-ilCH MAY ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL.
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6. ADE QUA TE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
OWNER'S CERTIFICATE:
I UNDERSTAND ANO ACKNOV.U:OGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT ANO TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; ANO (2) ADHERE TO, ANO AT All TIMES,
COMPLY WlTH THIS CHY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED
BY THE OTY OF CARLSBAD.
Jesse Leon
E-29
PRINT
SIGNATURE
10/28/24
DATE
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
CB
SW
Erosion Control Sediment Control BMPs Traddng Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs
C ! -~ 1j -0 ~ 0 -0 C ., 6 g' E C .. ~ .Q ·E 0 ~ 0 ~ .. .5 .5 '5 .9->-0 :::E -0 .,, "' g ~ ' ::, "' g' C 4' a. .s. .. E E~ 8 <T ~ g -~ Best Management Practice• .:,i o c 0 a, Q. t: ! I; w :c ~~ .,, ,= !l"' 0 _s; u 1' u ~ -0 ~ ~ 0 ] -., " .s. E .,, "' (D "' -0 .,, :::E ~ii (BMP) Description ➔ .. "3 ~4) e " 0 ~ 0 3' C ~] -g~ ~~ 0., 65 C 0 ::::, ~E :;:; ,. 0 ~ ii 0 a, ~-~ "' u 1: 0 C, " " K Oc,, "' 0 ~ ~ c,t:Z " ~--!g' :§ ~ o:e ~" j 0 " ... E -" 1 .0 s~ =. ~ti -~ ~ :c UC I; g "' 1 :-5 .E " I; "::, ~ :g ~ ~8 0 -0 0 Q. ii " _; g ~~ o.B =] ~o 0 .0 ~ -o ~J 0 0 ~~ o~ 6 ell i it WO vi iii (/) t.: V>> vi it iii C (/) a: Q. >U ,. (/) :,; iii o!"u
CASOA Designalioo ➔ .... a:, "' .,, .... "' <O .... a:, 0 N .,, .... (0 ' N .,, .... "' I I I I ' I I I I I ' I ' I ' I I I I ' ' I u u u u w w ~ w w ~ w w J!, J!, (/) (/) (/) (/) i i i i i Construction Activity w w w w (/) (/) (/) (/) (/) (/) z z z z
>I Grodino/Soi Disturbance X
Y Trenchino/Excovotion ',(
I><' Stockoilino y... X. Orillin° /Rorino
Concrete/Asoholt Sowcuttino
Concrete Flotworl<
Povino
Conduit/Pioe Installation
Stucco/Morter Work
'>( Waste Disposal
Stoaino /l av Down Area
Enuinment Maintenance end Fuelino
Hazardous Substance Use /Storooe
Oewoterino
Site Access Across Dirt
Other llistl:
Instructions:
1. Check the box to the left of ell applicable construction activity (first column) expected to occur during construction.
2. Located along the top of the BMP Tobie is o list of BMP's with it's corresponding Colifomio Stormwoter Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
J. Refer to the CASQA construction handbook for information end details of the chosen BMPs end how to apply them to the project.
SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE
ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN.
SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
EROSION CONTROL PLAN.
PROJECf INFORMATION
Site Address: 2800 Atadero Court
Assessor's Parcel Number. 255-101-22
Emergency Contact:
Name: Sheen Fischer
24 Hour Phone: 760-738-6270
Construction Threet to Storm Weter Quality
(Check Box)
□ MEDIUM ~ LOW
-;; ~-.,, ii i! E
-0 " ~ "' O 0 NC 0 0 :,::,;
<O ' i
-;;
o-~ ii
"E ~~ uo
66 u :,;
(0
I i
'I---.
Poge 1 of 1 REV 02/16
(Cityof
Carlsbad
SEWER DISTRICT CERTIFICATION
Leucadia Wastewater District
1960 La Costa Ave.
Carlsbad, CA 92009
(760) 753-0155
D Vallecitos Water District
201 Vallecitos de Oro
San Marcos, CA 92069
(760) 744-0460
The following project has been submitted for building permits:
Plan Check #: ____________ Permit #: _C_B_R_2_0_24_-_1_3_5_2 ______ _
Property Owner: JENSEN FAMILY TRUST 06-12-12
Project Address: 2800 ATADERO CT -----------------------------
Assessor's Parcel #: 2551012200 -----------------------------
Project Description: JENSEN: NEW 292 SF DETACHED ADU
City Certification: City of Carlsbad Building Division Date: October 22, 2024 _________ _;_ ______ _
Please indicate in the space below that the owner has entered into an agreement to have your
agency provide public sewer service to the premises, and/or if the existing service is adequate
for this project and all required conditions have been satisfied.
Permits will not be issued until this form is completed and returned to our office.
···----····· -··--·-··· -··················---·····-·-·-· ···········-------··········································----·--. . . .
This space to be completed by District Personnel
I certify the district requirements for sewer service have been sat isfied.
Approved by: t~.s -<~ Date: I\ /t {:ad
Title: CA~d:o.l Pcajec,,+ ®.,:aser . '················-············-·····································-·······--········--·--·········--·-························--·
COMMUNITY DEVELOPMENT -Building Division
1635 Faraday Ave I Carlsbad, CA 92008-7314 I 442-339·2719 I building@carlsbadca.gov I www.carlsbadca.gov
C cityof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov
This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements
apply to their project. This completed checklist (8-50) and summary (B-55) must be included with the building permit
application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
The 8-50 checklist was originally developed several years ago to support implementation of the CAP. Recent updates to
the California Building Standards Code have imposed newer performance standards on building permit applications.
Therefore, the applicant is advised to review all applicable code sections and apply the maximum performance standard,
which may exceed the CAP consistency checklist requirements
Consultation with a certified Energy Consultant is encouraged to assist in filling out th is document. Appropriate
certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy
compliance, IECC/HERS Compliance Specialist, ICC G8 Energy Code Specialist, RESNET HERS rater certified, certified
ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen
Inspector/Plans Examiner, or Green Building Residential Plan Examiner.
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
check N/A and provide an explanation or code section describing the exception.
The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and
Green Code sections.
Project Name/Building
Permit No.: Jensen ADU BP No.: Date: 5/22/24
PropertyAddress/APN: 2802 Atadero Court, Carlsbad, CA 92009 APN: 255-101-22
Applicant Name/Co.: Jesse Leon
Applicant Address: 10245 Casa Court, Santee, CA 92071
Contact Phone: 619-733-8134 Contact Email: jessealeon@hotmail.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
B-50
Contact Phone:
Contact Email:
Page 1 of 7 Revised 12/22
Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing
buildings, attach a Permit Valuation breakdown on a separate sheet. For purposes of determining valuation, the amount should be upon either
the actual contract price for the work to be permitted or shall be determined with the use of the current "ICC Building Valuation Data" as
published by the International Code Council, whichever is higher (refer to Section 18.04.035 of the CMC).
Building Permit Valuation (BPV) $ breakdown ___________ _
j COllllructlonTp I Compl1l18lclan(a>
II] Residential
~ New construction 2A*, 3A*, 4A* *Includes detached, newly constructed ADU
D Additions and alterations:
D BPV < $60,000 NIA All residential additions and alterations
D BPV ~ $60,000 1A, 4A 1-2 family dwellings and townhouses with attached garages
D Electrical service panel upgrade only only.
*Multi-family dwellings only where interior finishes are
D BPV ~ $200,000 1A, 4A* removed and significant site work and upgrades to structural
and mechanical, electrical, and/or plumbing systems are
proposed
2B* *Multi-family dwellings only where ~$1,000,000 BPV AND
BPV ~ $1,000,000 affecting ~75% existing floor area
0 Nonresidential and hotels/motels
D New construction 1 B, 2B, 3B, 4B and 5
D Alterations:
D BPV ~ $200,000 or additions~ 1B, 5 1,000 square feet
D BPV ~ $1,000,000 1B, 2B, 5 Building alterations of~ 75% existing gross floor area
~ 2,000 sq. ft. new roof addition 2B,5 1 B also applies if BPV ~ $200,000
Instructions:
1. Choose first between residential or non-residential based on the type of project being submitted.
2. Next chose between new construction or addition/alteration for residential or non-residential.
3. The columns to the right of your selection will determine which sections of the CAP program are applicable to your project.
4. Appropriate details must be included on the plans for selections made.
EXAMPLE:
Scope of work includes a new, 2 story, single family residential structure.
i
The selections would be: Residential and New construction in the table above. For a 2-story structure, CAP sections 2A, 3A and 4A would be
applicable. (Solar PV, water heating, EV charging) The • indicates that new detached ADU's are included.
EXAMPLE:
Scope of work includes a tenant improvement (i.e., alterations) valued at over one million dollars.
The selections would be: Non-residential and Alteration BPV ~ $1 ,000,000. CAP sections 1 B, 28 and 5 would be applicable to this project. (Energy
efficiency, Solar PV and Transportation Demand Management (TOM)*)
It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with
CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need
to attach to this checklist separate calculations and documentation as specified by the ordinances.
3
1. Energy Efficiency
Please refer to Section 18.30.060 of the Carlsbad Municipal Code (CMC) and Section 150.2 of the CEC for more information. Appropriate
details and notes must be placed on the plans according to selections chosen in the design.
A. 0 Residential addition or alteration .?: $60,000 building permit valuation.
Details of selection chosen below must be placed on the plans
referencing CMC 18.30.060.
D N/A _________ _
D Exception: Home energy score
~ 7 (attach certification)
Year Built Single-family Requirements Multi-family Requirements
D Before 1978 Select one option:
D Duct sealinQ D Attic insulation □Coolroof D Attic insulation
D 1978 and later Select one option:
D Lighting package D Water heating package
D Between1978 -1991 Select one option:
D Duct sealing D Attic insulation D Cool roof
D 1992 and later Select one option:
D Lighting package D Water-heating package
B. 0 New Nonresidential construction (including additions over 1,000sf), new hotel/motel construction AND alterations ~
$200,000 building permit valuation. See Section 18.21.050 of the CMC and CALGreen Appendix AS.
At least one measure from each applicable building component required. 0 N/A _______ _
AS.2O3.1.1 Choose one:
D Outdoor lighting D Restaurant service water heating (Section 140.5 of the CEC)
D Warehouse dock seal doors D Daylight design PAFs D Exhaust air heat recovery
AS.2O3 .1 .2.1 Choose one: D .95 Energy budget
(Projects with indoor lighting OR mechanical)
D .90 Energy budget
(Projects with indoor lighting AND mechanical)
AS.211 .1 ** D On-site renewable energy:
AS.211.3** D Green power: (If offered by local utility provider, 50% minimum renewable sources)
AS.212.1 D Elevators and escalators:(Project with more than one elevator or two escalators)
AS.213.1 D Steel framing: (Provide details on plans for options 1-4 chosen)
* High-rise residential buildings are 4 or more stories.
0 N/A ----------
0 N/A ________ _
0 N/A
0 NIA
0 N/A
0 N/A. ________ _
** For alterations~ $1 ,000,000BPV and affecting> 75%existing gross floor area, OR alterations that add 2,000 square feet of new roof addition: comply
with Section 18.030.040 of the CMC (section 28 below) instead.
4
2. Photovoltaic Systems
Residential new construction. Refer to Section 150.1 (c)14 of the CEC for single-family requirements and Section
170.2(d) of the CEC for multi-family requirements. If project includes installation of an electric heat pump water
heater pursuant to CAP section 3 below (residential water heating), increase system size by .3kWdc if PV offset
option is selected.
Floor Plan ID (use additional CFA or SARA #d.u. Calculated kWdc* Exception
sheets if necessary)
ADU 292 1 0 0 N/A per title 24
D
□
□
Total System Size: kWdc
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
B. □ Nonresidential, hotel/motel and multifamily additions, alterations and repairs of these projects ~$1,000,000 BPV AND
affecting ~75% existing floor area, OR addition that increases roof area by ~2,000 square feet. Please refer to
Section 18.30.040 and 18.30.070 of the CMC when completing this section.
Choose one of the following methods: (Gross floor area or Time-Dependent Valuation method)
D Gross Floor Area (GFA)Method
GFA: Min.System Size: kWd
D If< 1 O,OOOs.f. Enter: 5 kWdc
D If~ 1 O,OOOs.f. calculate: 15 kWdc x (GFA/10,000) **
**Round building size factor to nearest tenth, and round system size to nearest whole number.
D Time-Dependent Valuation Method
C. 0
Annual TDV Energy use:*** ______ x .80= Min. system size: ______ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
* All newly constructed non residential, hotel/motel and highrise multifamily buildings that are required by CEC section
140.10(a) to have a PV system shall also have a battery storage system meeting CEC section 140.10(b). Non
residential, hotel/motel and multifamily additions, alterations or repairs that trigger solar due to the Carlsbad Climate Action
Plan will NOT require battery storage. Battery storage is required when triggered by CEC section 140.10(a) and/or 170.2(9).
5
3. Water Heating
A. Residential. Refer to Section 18.30.050 of the CMC and Sections 150.1 (c)8 or 170.2(d) of the CEC when completing this
section. Provide complete details on the plans.
Residential new construction and alterations:
□ Required: 60% of energy needed for service water heating from on-site solar or recovered energy.
For systems serving individual units, choose one system:
"" Single 240-volt heat pump water heater AND compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
□ Single 240-volt heat pump water heater AND PV system .3 kWdc larger than required.
□ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher.
□ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
□ Gas or propane system with a solar water hearing system and recirculation system.
For systems serving multiple units, choose one system:
□ Heat pump water heating system with recirculation loop tank and electric backup.
□ Solar water heating system that is either:
□ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recover
OR:
□ System meets performance compliance requirements of section 150.1(d) or 170.2(d) and deriving at least 60% of energy from
on-site solar or recovered energy.
□ Exception: ______________________________________ _
8. Nonresidential and hotel/motel new construction. This section also applies to high-rise residential. Refer to Sections 18.030.020
and 18.040.030 of the CMC and Sections 140.5 and 170.2 of the CEC when completing this section. Provide complete details
on the plans.
1. Non-residential:
□ Required: Water heating system derives at least 40% of its energy from one of the following:
□ Solar-thermal □ Photovoltaics □ Recovered energy
□ Required: High-capacity service water heating system
2. Water heating system is (choose one):
D Heat pump water heater
□ Electric resistance water heater(s)
□ Solar water heating system with .40 solar savings fraction
3. Hotel/motel:
□ Required: High-capacity service water heating system (meeting Section 170.2( d) of the CEC)
□ Required: Located in garage or conditioned space
Exception:
6
4. Electric Vehicle Charging
A. liJ Residential • New construction and major alterations.* This section also applies to hotel/motel projects. Refer to Section
18.21.030 of the CMC and Section 4.106.4 of the GBSC when completing this section.
Choose one:
□ One and two-family residential dwelling alterations with attached private garage. (not required if a panel upgrade would be needed)
□ New detached ADU. (no EV space required when no additional parking facilities are added)
□ New one and two-family residential dwellings and townhouse with attached private garage. . . □ One EV Ready parking space required !!!!I Exception: No parking required
□ New and major alterations to multi-family and hotel/motel projects: □ Exception: ________________ _
Total Parking Spaces Proposed EVSE Spaces
EV Capable (10% of total) I EV Reoov (25% of Total) I EV charqers (5% of Total)
I I
*Major alterations are:
(1) for one and two-family dwellings and for town houses with an attached garage, alterations have a building permit valuation ~$60,000 or
include an electrical service panel upgrade.
(2) for multifamily dwellings (three un~s or more without attached garages), alterations have ab uilding permit valuation ~ $200,000, i nteriorfinishes a re
removed and significant site work and upgrades to structural and mechanical, electrical, a nd/orp lumbing systems are proposed.
B. D Non-Residential -New construction □ Exception : _____________ _
Please refer to Section 18.21.040 of the CMC when completing this section
Total Par1<ing Spaces
Proposed EV Capable I EVCS (Installed with EVSE) I EV Ready (optional) I EV Space (optional)
I I I
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Capable Spaces Number of required EVCS (Installed with EVSE)
□ 0-9 1 1
□ 10-25 4 1
□ 26-50 8 2
□ 51-75 13 3
□ 76-100 17 5
□ 101-150 25 6
□ 151-200 35 9
□ 201 andover 20 percent of total 25 percent of Required EV Spaces
Calculations: Total EV Capable spaces= .20 x Total parking spaces proposed (rounded up to nearest whole number)
EVSE Installed= Total EVSE Spaces x .25 (rounded up to nearest whole number)
EVSE other maybe "EV Ready" or "EV Space"
7
5. D Transportation Demand Management (TOM): Nonresidential ONLY
An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether your permit requires a TDM plan. If TDM is applicable to
your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
Use
Office (all)2
Restaurant
Retaib
Industrial
Manufacturing
Warehousing
EmpADTfor
first 1,000 s.f.
20
11
8
4
4
4
EmpADTI
1000 s.f.1
13
11
4.5
3.5
3
1
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 1 ()th Edition
2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
sample ca1cu1atjons:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT
I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be
contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance.
Applicant Signature: __________ _
Name: Jesse Leon
Date: 5/22/24
Phone No.: 619-733-8134
8
C Cityof
Carlsbad
CLIMATE ACTION PLAN (CAP} COMPLIANCE
CAP Building Plan
Template
B-55
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
The following summarizes project compliance with the applicable Climate Action Plan ordinances of the Carlsbad Municipal Code and California
Green Building Standards Code (CALGreen), current version. The following certificate shall be included on the plans for all building permits that
are required to comply with the CAP measures:
1. ENERGY EFFICIENCY APPLICABLE: □YES □ NO
Complies with CMC 18.30.060
or 18.21.050 O Yes D N/A
Existing Structure, year built: _____ _
Prepared Energy Audit? Q es D No
Energy Score: _____ _
Efficiency Measures included in scope:
NIA per title 24
2. PHOTOVOLTAIC SYSTEM APPLICABLE: DYES [j] NO
Complies with CMC section 18.30.040 and 2022 California Energy
Code section 150.l(c}14 D Yes D IA
Size of PV system (kWdc):
Sizing PV by load calculations O Yes O No
If by Load Calculations:
Total calculated electrical load:
80% of load:
Exception Requested
Exception Approved
0 Yes ~ D Yes ONo
3. ALTERNATIVE WATER HEATING SYSTEM APPLICABLE: [j] YES □ NO
4.
5.
Complies with CMC sections 18.30.020
[Z]yes D N/A 18.20.030 and/or 18.30.050?
Alternative Source:
o Electric
o Passive Solar
Exception Requested
Exception Approved
D Yes
□Yes
□No
□No
ELECTRIC VEHICLE (EV) CHARGING APPLICABLE: DYES [j]NO
Complies with CMC
section 18.21.030?
Panel Upgrade?
Total EV Parking Spaces:
No. of EV Capable Spaces:
No. of EV Ready Spaces:
No. of EV Installed Spaces:
Hardship Requested
Hardship Approved
D Yes O N/A D Yes O No
Required Provided
----r:'jves
□Yes
ONo
□No
TRAFFIC DEMAND MANAGEMENT APPLICABLE: DYESDNo
0Yes ONo
□Yes oNo
Compliant?
TOM Report on file with city?