HomeMy WebLinkAbout2736 LOKER AVE WEST; ; AS030001; Permit10/16/25, 4:03 PM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: about blank Fees($) 100 AS030001 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS030001 2736 LOKER AV WEST SPRINK 0 HISAMITSU Add'I Fees ($) 0 Status: Applied Approved: Issued: Inspector: Owner: Total($) 100 ISSUED 1/2/2003 2/28/2003 2/28/2003 Balance($) 0 1/1 LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. SUITE. F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 TRANSMITTAL ~'lfSo;O{()/ COMPANY: FROM: CARLSBAD FIRE CHUCK HOLLANDS ATIN: DATE: PLAN REVIEW JAN. 15,2003 ADDRESS: FAX NUMBER: RE: HISAMITSU T.I. RESUBMITTAL NOTES/COMMENTS: THE CHANGES YOU REQUESTED HAVE BEEN MADE. RESUBMITTING: 4 SETS OF PLANS. 2 SETS OF MATERIAL DATA SHEETS. PLEASE CALL IF YOU HAVE ANY QUESTIONS. FIRE PROTECTION DESIGN & INSTALLATION CALIFORNIA LICENSE #758459 t)O .00 MATERIAL DATA SUBMITTAL HISAMITSU T.I. 2736 LOKER AVE. WEST STE. A$ B CARLSB?D,CA.92008 LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92056 760-806-9997 • 760-806-4813 F,.AX EXTENDED COVERAGE ORDINARY HAZARD SPRINKLERS MODEL F895 DESIGNER, K=11.2 & K=14.0, 3/4" NPT** For NFPA Unobstructed or Non-Combustible Obstructed Ceiling Construction WRENCH FLAT 2 2-7/16" 1 3 (61,9 mm) 4 1-11/16" 5 (42,7 mm) 6 7------1! 7/16~ (11, 1 mm) CROSS SECTION PENDENT 1 -Frame 2 -Button ESCUTCHEON PLATE SEATING SURFACE 2-7 /8" (7~,0 mm) DIA. RECESSED PENDENT MODEL f700 RECESSED ESCUTCHEON WRENCH FLAT 3 • Gasketed Spring Plate 4 -Bulb 6 -Deflector· 5 • Compression 7 -Pintle Screw 7/16" (11,1 mm) t 2-7/16" (61,9 mm) l 1/2" (12,7 mm) MAKE-IN Temperature rating is indicated on deflector. .. Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE A EXTENDED COVERAGE ORDINARY HAZARD SPRINKLERS 11.2 K-FACTOR MODEL F895 (SIN G1893) PENDENT & (SIN G1894) UPRIGHT 14.0 K-FACTOR MODEL F895 (SIN G1895) PENDENT & (SIN G1896) UPRIGHT GENERAL DESCRIPTION The 11.2 and 14.0 K-factor, Model F895 Designer Extended Coverage Ordinary Hazard (ECOH) Pendent, Recessed Pendent, and Upright Sprin- klers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for the protection of ordinary hazards up to a maximum coverage area of 256 tt2 (23,8 m2) for the 11.2 K-factor and 400 ft2 (37,2 m2) for the 14.0 K-factor, as com- pared to the maximum coverage area of 130 ft2 (12, 1 m2) for standard cover- age sprinklers. The F895 ECOH Sprinklers have been fire tested to compare their perform- ance to that of standard spray sprin- klers installed at standard spacings (i.e. 15 feet maximum on center spac- ing and 130 sq. ft. maximum coverage area for ordinary hazard). These tests Printed in U.S.A. 2-00 have shown that the protection pro- vided by the F895 ECOH Sprinklers is equal to or more effective than stand- ard spray sprinklers. The recessed version of the F895 ECOH Sprinkler is obtained by com- bining the pendent sprinkler with the Model F700 Recessed Escutcheon (Ref. Figures A and B). The F700 Re- cessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19, 1 mm) of adjustment from the flush pendent position. The F700 is a separable two-piece design which allows installation of the sprin- klers and pressure testing of the fire protection system, prior to ceiling con- struction and/or application of a finish coat to the ceiling. They also permit refinishing of a ceiling surface without having to first shut down the fire pro- tection system and remove sprinklers. The adjustment provided by the F700 substantially reduces the accuracy to which the fixed pipe drops to the sprin- klers must be cut. Also, the Closure has a 1/2 inch (12,7 mm) wide flange which provides ample clearance for covering the mounting hole. APPROVALS AND STANDARDS Laboratory listings and approvals for the 11.2 and 14.0 K-factor, Model F895 Extended ' Coverage Ordinary Hazard (ECOH), Pendent, Recessed Pendent, and Upright Sprinklers are given in Table A. The laboratory listings and approvals only apply to the service conditions indicated in the 'Technical Data and Design Criteria sections. WARNING The Model FB9!5 ECOH Sprinklers described herei11 must be installed and maintained· in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any other TD596A SPRINKLER FINISH TEMPERATURE BULB NATURAL CHROME TYPE RATING COLOR BRASS PLATED CODE 135°F/57°C Orange PENDENT 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4 UPRIGHT 200°F/93°C Green 286°F/182°C Blue 135°F/57°C Orange 155°F/68°C Red RECESSED• 1,2,4 175°Fn9°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters Laboratories for use in Canada (i.e. C-UL Listed). 3. Approved by Factory Mutual Research Corporation. 4. Approved by the Scientific Services Laboratory (Australia) . * Installed with 3/4 Inch Model F?00 Recessed Escutcheon TABLE A POLYESTER LEAD COATED CqATED 'All Colors' I I 1, 2, 3, 4 LABORATORY LISTINGS AND APPROVALS (The laboratory listings and approvals only apply to the service conditions indicated in the Technical Data and Design Criteria sections.) ' authorities having jurisdiction. Fail- ure to do so may impair the integrity of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should be contacted relative to any questions. TECHNICAL DATA The 11.2 and 14.0 K-factor, Model F895 Extended Coverage Ordinary Hazard (ECOH) Pendent, Recessed Pendent, and Upright Sprinklers are rated for use at a maximum service pressure of 175 psi (12, 1 bar) and they are available in the temperature rat- ings and finishes indicated in Table A. Recessed versions of the F895 ECOH Sprinklers are obtained by utilizing the Model F895 Pendent Sprinkler in com- bination with the Model F700 Re- cessed Escutcheon. The Model F700 Escutcheons are available either with a chrome plated finish or a coated fin- ish in any color. The flow "Q" in GPM (LPM) is deter- mined by the formula: where the nominal sprinkler discharge coefficient "K" equals either 11.2 (161.3) or 14.0 (201.6); and "p" = pressure in psi (bar). The Frame of the Model F895 Sprin- kler, (Ref. Figure A), is brass per ASTM B584 (C83600 or C84400). The Button (bulb retainer) is phosphor bronze per ASTM B103 (C54400) or brass (C36000). The Gasketed Spring Plate consists of a Beryllium Nickel (N03360) disc spring that is sealed on both its inside and outside faces with a Teflont gasket. The Compression Screw is bronze per ASTM B 140 (C31400) and the Deflector is brass per ASTM B36 (C22000, C24000, or C24000). The Pintle is stainless steel (S42000). The Model F895 Sprinklers utilize a 3 mm diameter frangible bulb. Table A indicates the bulb liquid color as a function of temperature rating. The F700 Recessed Escutcheon pro- vided for use with the F895 ECOH Sprinklers (Ref. Figure B) has a Clo- sure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it, maintain a tight friction fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and compensate for non-perpendicularity between the F895 ECOH Sprinkler and the ceiling. -2- DESIGN CRITERIA The Model F895 ECOH Sprinklers must only be installed in accordance with the applicable UL and C-UL List- ing or FM Approval requirements, as indicated below. Only the Model F700 Recessed Escutcheon is to be used for recessed installation: UL and C-UL Listing Requirements 1. The F895 Sprinklers may be used for the coverage areas shown in Table B, based on maintaining the mini- mum specified flow rate, as a func- tion of coverage area and hazard group, for all of the sprinklers in the design area. 2. With repect to heat sensitivity, the F895 ECOH Sprinklers are permit- ted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permit- ted by NFPA 13. For example: • Unobstructed, bombustible or noncombustible, ceiling con- struction with a deflector to ceil- ing/roof deck distance of 1 to 12 inches (25 to 300 mm). • Obstructed, noncombustible, ceiling construction with a de- flector location below structural members of 1 to 6 inches (25 to 300 mm) and a maximum deflec- tor to ceiling/roof deck distance of 22 inches (550 mm). 3. The minimum allowable spacing be- t DuPont Regis\ered Trademark FULLY RECESSED DIMENSIONSt Up to 1/2 inch adjustment from minimum 1/4 inch to maximum 3/4 inch recessed position. Dim. A- B-Min. B-Nom. B-Max. C-Min. C-Max. Inches MM 5/8 1/8tt 15.9 3,2 7/8 1-1/8 1-3/8 1/4 3/4 HIGH ADJUSTMENT DIMENSIONS 22,2 28,6 34,9 6,4 19,1 Up to 3/4 inch adjustment from the flush ceiling position to 3/4 inch recessed position. Dim. Inches MM A-1/2 1/4tt 12,7 6,4 8-Min. 7/8 22,2 B-Nom. 1-1/4 31,8 8-Max. 1-5/8 41,3 C-Min. FLUSH C-Max. 3/4 19, 1 t For best overall appearance. ~ t Remaining 1 /4 inch (6,4 mm) of adjustment can be used to compensate tor variations in sprinkler make-in and fitting take-out. FACE OF FITTING 2-7 /8" DIA. (73,0 mm) 2~7/4" DIA. (:'.i7,2 mm) MOUNTING ·-~L_-_-_-;r::_-;;__=_:ztt_z_::;-t;i:-::;i~J.,.,-,,,lti!'-!-!!~:::J SURFACE A 8 j 2 2a 1-Model F895 ECOH Pendent Sprinkler 2-Model F700 Recessed Escutcheon a-Mounting Plate b-Closure FIGURE B 1 /8" (3,2 mm) J MODEL F895 ECOH RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F700 RECESSED ESCUTCHEON tween the F895 ECOH Sprinklers, to prevent cold soldering, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. 4. The Model F895 ECOH Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage upright and pendent sprinklers. FM Approval Requirements The F895 ECOH Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to-ceiling distance. INSTALLATION NOTE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bub- ble should be present. The diameter of the air bubble is approximately 1 I 16 inch (1,6 mm) for the 135°F 157°C to 3 I 32 inch (2,4 mm) for the 286°F/ 141°C temperature ratings. (The bubble, in some cases, may be barely perceptible for the lower tem- perature ratings.) The Model F895 ECOH Sprinklers must be installed in accordance with the following instructions. 1. Prior to installing each sprinkler, ver- ify that the face of the sprinkler fitting is within the proper range of distance which can be accommodated by the particular type of escutcheon. -3- When installing the F895 Sprinkler with the F700 Recessed Escutch- eon, tor best overall appearance, use Dimension "A" indicated under the "Fully Recessed Dimensions" heading of Figure 8. Otherwise, use Dimension "A" under the "High Ad- justment Dimensions" heading. In either case, the remaining adjust- ment can then be used to compen- sate for the possible manufacturing variations in the take-out of the fit- tings, as well as in the make-in of the sprinklers (as permitted by ANSI 81.20.1). 2. The sprinkler must be installed with the deflector parallel to the mounting surface. Pendent sprinklers must be installed in the pendent position, and upright sprinklers must be installed in the upright position. 3. After installing the F700 mounting plate (or other escutcheon, as appli- cable) over the, sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand K=11.2 Coverage Area (a) Maximum Distance From Ft.x Ft. Sq.Ft Wall(b) Ft. 14 X 14 196 7 16 X 16 256 8 K=14.0 Coverage Area (a) Maximum Distance From Ft. X Ft. Sq. Ft. Wall (b) Ft. 16 X 16 256 8 18 X 18 324 9 20x20 400 10 NOTES: ORDINARY HAZARD GROUP1 0.15 gpm/tt2 Density Minimum Minimum Flow, Pressure, GPM PSI 29.6 7.0 38.4 11.8 ORDINARY HAZARD GROUP1 0.15 gpm/tt2 Density Minimum Minimum Flow, Pressure, GPM PSI 38.4 7.5 48.6 12.1 60.0 18.4 ORDINARY HAZARD GROUP 2 0.20 gpm/tt2 Density Minimum Minimum Flow, Pressure, GPM PSI 39.2 12.3 51.2 20.9 ORDINARY HAZARD GROUP 2 0.20 gpm/tt2 Density Minimum Minimum Flow, Pressure, GPM PSI 51.2 13.4 64.8 21.4 80.0 32.7 Conversion Factors 1 ft.= 0,3048 m • 1 sq. ft.= 0,093 m2 1 gpm = 3,785 1pm 1 psi = 0,06695 bar 1 gpm/tt2 = 40,74 mm/min (a} For spacing dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next higher spacing (e.g., if the required spacing is 15' x 17', the minimum flow rate for the 18' x 18' coverage area must be applied). (b) The distance from a sprinkler to a wall (or boundary of the sprinkler coverage area) must not exceed one-half of the maximum specified distance between sprinklers (e.g., if the minimum flow rate for a 14' x 14' coverage area is being applied, the maximum allowable distance between sprinklers is 14 feet and one-half of the maximum specified sprinkler spacing is 7 feet. TABLE B UL AND C-UL LISTING CRITERIA FOR THE INSTALLATION OF MODEL F895 ECOH SPRINKLERS tighten the sprinkler into the sprin- kler fitting. 4. Wrench tighten upright or pendent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprin· klers using only 1he W-Type 4 Sprin- kler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figures C and D) is to be applied 10 the sprinkler wrench 1Ia1s (Ref. Fig· ure A). NOTES A leak tight 3 I 4 inch NPT sprin- kler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or im- pairment of the sprinkler. Do not attempt to make-up for in- sufficient adjustment in the es- cutcheon plate by under-or over- tightening the sprinkle,: Readjust the position of the sprinkler fitting to suit. 5. In recessed installations, after the ceiling has been installed or 1he fin- ish coa1 has been applied, slide on 1he F?00 Closure over the F895 Sprinkler and push the Closure over the Mounting Plate until its flange comes in con1act wi1h the ceiling. -4- CARE ANO MAINTENANCE Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/38°C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -both before and after installation. Sprinklers dam- aged by dropping, striking, wrench twisVslippage. or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (rel. Installation Section). NOTE BefOre closing a fire protection system control ualve for maintenance work on the fire protection system which it con- trols, permission to shut down the af- fected fire protection system must be obtained /Tom the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quar- terly by a qualified Inspection Service. WARRANTY Seller warrants tor a period at one year tram the date of shipment (warranty period) that the products turnished hereunder will be free tram defects in material and workmanship. For further details on Warranty, see Price List. "FITTING SIDE" TOWARDS SPRINKLER FITTING FIGURE C WRENCH RECESS (END "A") W-TYPE 3 SPRINKLER WRENCH (For Pendent & Upright Installations ) fr ® FIGURED ¢:J (i) WRENCH LUGS W-TYPE 4 SPRINKLER WRENCH (For Recessed Installations) PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS UNIVERSAL MODEL A STANDARD RESPONSE, 5mm BULB TYPE, 1/2" (15mm) ORIFICE, 1/2" NPT** MODEL WRENC~ FLAT 2-3/1611 (55,6mm) 1/211 2-3/16" (55,6mm) t SSP DEFLECTOR* PENDENT F700 RECESSED ESCUTCHEON ** t NPT ------2-7/8" (73,0mm) DIA,----<~ 7/16" (11 Imm) MAKE-IN RECESSED PENDENT UPRIGHT CROSS SECTION 1 -Frame 2 -Button 3 -Gasketed Spring Plate 4-Bulb 5 -Compression Screw • Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE A 6 -Deflector 1/2 INCH ORIFICE MODEL A PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS GENERAL DESCRIPTION The 1/2 inch (15mm) orifice Universal Model A Pendent, Recessed Pendent, and Upright Sprinklers (Ref. Figure A) are automatic sprinklers of the frangi- ble bulb type. They are "standard re- sponse -standard orifice spray sprink- lers" intended for use in fire sprinkler systems designed in accordance with the standard installation rules recog- nized by the applicable Listing or Ap- proval agency (e.g., UL Listing is based on NFPA 13 requirements). The Pendent, Recessed Pendent, and Up- right Sprinklers all produce a hemi- spherical water distribution pattern below the deflector. The recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- nation with the Model F700 Recessed Escutcheon (Ref. Figures A and C). The F700 Recessed Escutcheon pro- vides 1/2 inch (12,7mm) of recessed adjustment or up to 3/4 inch (19, 1 mm) of adjustment from the flush pendent position. The F700 has a separable two-piece Printed in U.S.A. 4-94 design which allows installation of the sprinklers and pressure testing of the fire protection system, prior to ceiling construction and/or application of a fin- ish coat to the ceiling. They also permit refinishing of a ceiling surface without having to first shut down the fire pro- tection system and remove the sprink- lers. The adjustment provided by the F700 substantially reduces the accuracy to which the length of fixed pipe drops to the sprinklers must be cut. Also, the Closure·has a 1/2 inch (12,7mm) wide flange which provides ample clear- ance for covering 1he mounting hole. APPROVALS AND STANDARDS Laboratory listings and approvals for the 1 /2 inch (15mm) orifice Model A Pendent, Recessed Pendent, and Up- right Sprinklers are given in Table A. WARNING The 1 I 2 inch orifice Model A Pendent, Recessed Pendent, and Upright Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as applicable standards of the National Fire Protection Association, in addi- tion to the standards of any other au- thorities having jurisdiction. Failure to do so may impair the integrity of these deuices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should be contacted rel- ative to any questions. Installation of Model A Pendent Sprinklers in recessed escutcheons other than the F700 will void all sprinkler warranties, as well as possi- bly void the sprinkler's Approvals and I or Listings. TECHNICAL DATA i The 1/2 inch (15mm) orifice Model A Pendent, Recessed fendent, and Up- right Sprinklers are rated for use at a maximum service pri,ssure of 175 psi (12, 1 bar) and they are available in the TD516M SPRINKLER FINISH TYPE TEMPERATURE FRAME BULB NATURAL CHROME POLYESTER RATING COLOR LIQUID BRASS PLATED COATED CODE COLOR (All Colors) 135"F/STC Unpainted Orange 1 SS"F/68"C Unpainted Red PENDENT 175"F/79"C White Yellow and 1, 2, 3, 5, 6 UPRIGHT 200'F/93'C White Green 286"F/141'C Blue Blue 360"F/182"C Red Mauve 135"F/57'C Unpainted Orange RECESSED 155"F/68"C Unpainted Red PENDENT' 175"F/79'C 1,2,4,6 1, 2, 6 White Yellow 200"F/93"C White Green NOTES: 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters· Laboratories of Canada. 3. Approved by Factory Mutual Research Corporation. 4. Approved by Factory Mutual Research Corporation for use in Light Hazard and Ordinary Hazard (Groups 1 and 2) Occupancies.The FM Approvals for Ordinary Hazard Occupancies is limited to wet pipe sprinkler systems and preaction systems qualifying as wet pipe systems. 5. Approved by the Loss Prevention Council (United Kingdom). 6. Approved by the Scientific Services Laboratory (Australia). Installed with 1/2" Model F?00 Recessed Escutcheon. TABLE A temperature ratings and finishes indi- cated in Table A. Recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- nation with the Model F700 Recessed Escutcheon. The F700 Escutcheons are available with a chrome plated fin- ish or a coated finish in any color. The nominal discharge curve plotted in Figure B represents the flow "O" in GPM (LPM) as determined by the fol- lowing formula: where the nominal discharge coeffi- cient "K" equals 5.6 (80,7): and, "p" equals the residual flowing pressure in psi (bar). Listing standards permit the actual value of "K" to vary from 5.3 to 5.8 (76,4 to 83,6): however, for hydrau- lic calculations, a K-factor of 5.6 (80, 7) is to be applied. The Frame of the Model A Sprinkler (Ref. Figure A), is bronze per ASTM 8176 (C87800) or, a proprietary alloy designated as QM. The Button (bulb retainer) is phospher bronze per ASTM 8103 (C51000 or C52100). The Gasketed Spring Plate consists of a Berylium Nickel (N03360) disc spring that is sealed on both its inside and outside faces with a Teflont gasket. The Compression Screw is bronze per ASTM 8140 (C31400) and the Deflec- tor is brass per ASTM 8152 (C11000). The Model A Sprinklers utilize a 5mm LABORATORY LISTINGS AND APPROVALS diameter frangible bulb. Table A indi- cates the bulb liquid color as a function of temperature rating. The F700 Recessed Escutcheon pro- vided for use with the Model A Pendent Sprinkler (Ref. Figure C) has a Closure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it, maintain a tight fric- tion fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and com- pensate for minor non-perpendicular- ity between the Model A Sprinkler and the ceiling. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of" liquid lrom the bulb. With the sprinkler held horizontal, a sniall air bubble should be present. The diame- ter of the air bubble is approximately 1 I 16 inch (1,6mm) /"or the 135 "FI 57 ·c to 3 I 32 inch (2,4mm) for the 360"F/182"C rating. (At higher ambient teniperatures, the bubble may be barely perceptable /'or the lower temperature ratings.) Installation of" Model A Pendent Sprinklers in recessed escutcheons other than the F700 will void all sprinkler warranties, as well as possi- DISCHARGE IN U.S. GALLO~ PER MINUTE (GPM) ,0 " " " 0 35 50 PARTIA L CURVE ONL y i '·' MAX. PR !:$$URE 175 P$I -·~ ,, Q":. i~: ~ ~ ~ r_ 1 cf ' o" • "· '·' '·' il 1 it I, '.o C PA~TIAL CURVE ONLY MAX. PlflESSURE 12,1 BAR I11I l!l 11 1111111 0,5 50 15 ,oo 1 12s ,so DISCHARGE IN LITR~S PER MINUTE FIGU~E B NOMINAL DISCHrRGE CURVE bly void the sprinkler's Approvals and I or Listings. r The Model A Sprin~lers must be in- stalled in accordanC with the follow- ing instructions. 1. Prior to installing endent sprinklers and if applicable, erify that the face of the sprinkler f tting is within the proper range of istance which can be accommodat d by the type of escutcheon bein9 used. When installing al Model A Pendent ' t DuPont Regi~tered Trademark ! FULLY RECESSED DIMENSIONSt Up to 1/2 inch adjustment from minimum 1/4 inch to maximum 3/4 inch recessed position. Dim. A· B-Min. 8-Nom. B-Max. C-Min. C-Max. Inches MM 5/8±1/8tt 15,9±3,2 3/4 1 1-1/4 1/4 3/4 HIGH ADJUSTMENT DIMENSIONS 19, 1 25,4 31,8 6,4 19, 1 Up to 3/4 inch adjustment from the flush ceiling position to 3/4 inch recessed position. Dim. Inches MM A-1/2±114tt 12,7±6,4 8-Min. 3/4 19, 1 8-Nom. 1-1/8 28,6 8-Max. 1-1/2 38,1 C-Min. FLUSH C-Max. 3/4 19, 1 Sprinkler with the F700 Recessed Escutcheon, for best overall appear- ance, use Dimension "A" indicated under the "Fully Recessed Dimen- sions" heading of Figure C. Other- wise, use Dimension "A" under the "High Adjustment Dimensions" heading. In either case, the remain- ing adjustment can be used to com- pensate for the possible manufac- turing variations in take-out of the timing, as well as in the make-in of the sprinklers (as permitted by ANSI B1 .20.1 ). 2. After installing the F700 Mounting Plate (or other escutcheon, as appli- cable) over the sprinkler threads, apply pipe thread sealant sparingly to the sprinkler threads only. Use of a Teflont based pipe thread sealant is recommended. 3. Hand tighten the sprinkler into the sprinkler fitting. 4. Refer to Figure D and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. The F850 Sprinkler Wrench must be used for installing polyester coated sprinklers, in order to prevent dam- age to the sprinkler finish. NOTES A leak tight 1 I 2 inch NPT sprink- 2-7/811 DIA. (73,0mm) FACE 2-1/4" DIA. OF FITTING (57,2mm) t For best overall appearance. tt Remaining 1/4 inch (6,4mm) of adjustment can be used to compensate for variations in sprinkler make-in and fitting take-out. I 1-Model A Pendent Spri~kler 2-Modal F700 Recesse~ Escutcheon a-Mounting Plate ! FIGURE C b-Closure 1· MODEL A RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F700 RECESSED ESCUTCHEON lerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install the sprinklers. Higher lev- els of torque may distort the sprinkler inlet with consequent leakage or impainnent of the sprinkle,: Do not attempt to make-up for in- sufficient adjustment in the es- cutcheon plate by under-or over- tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. 5. In recessed pendent sprinkler instal- lations, after the ceiling has been installed or the finish coat has been applied, slide on the F700 Closure over the Model A Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their temper- atures will exceed 1 00'F/38'C and they must never be painted, plated, coated or otherwise altered after leav- ing the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of I combustion, but har,e not operated, should be replaced it they cannot be completely cleaned by wiping the sprinkler with a cloth, or by brushing it with a soft bristle brush. I Care must be exerci$ed to avoid dam- age to the sprinkler~ -both before and after installation!' Sprinklers dam- aged by dropping, striking, wrench twisVslippage, or tha like, must be re- placed. Also, replace,any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). NOTS Absence of an escu cheon, which is used to cover a cle ranee hole, may delay the tim.e to sp inkier operation in a fire situation. Before closing a fire rotection system .. control valve for mai tenance work on the fire protection sy teni which it con- trols, permission to hut down the af- fected fire protectio system must be obtained from the p oper authorities and all personnel wli,o may be affected by this action must ~e notified. I It is recommende~ that automatic sprinkler systems b~ inspected quar- terly by a qualified In pection Service. SELECTION: Select the appropriate wrench based on the following require- ments: A. Model A Sprinklers with a natu- ral brass or chrome plated fin- ish and where the Wrench Flats shown in Figure A are accessi- ble, may be be installed using an 8 or 10 inch adjustable Cres- cent type wrench or the Model F850 Sprinkler Wrench. B. Model A Sprinklers with a poly- ester coated finish must only be installed with the Model F850 Sprinkler Wrench. C. Model A Recessed Pendent Sprinklers which are to be in- stalled after completion of a fixed ceiling must only be in- stalled with the Model F850 Sprinkler Wrench. USE: t ® ; ' ' : ~----- ' --, "----- r: ' I I I 1 'l<---,-,----r-,--"" I I I l __ 1. ___ ..J.._) '-'---~~~~--4' L-J.-~~ WRENCH LUGS------' Model F850 Nylon Coated Sprinkler Wrench When using an 8 or 10 inch adjustable Crescent type wrench, the wrench is to be applied to the sprinkler wrench flats only (Ref. Figure A). To use the F850 Sprinkler Wrench, slip the Wrench opening over the Model A Sprinkler Deflector by passing the Sprinkler Wrench around the side of the Sprinkler as shown in the above illustration. Using a 1/2 inch ratchet drive or by applying an 8 or 10 inch adjustable wrench to the hex end of the Sprinkler Wrench, tighten the sprinkler into the fitting. The two lugs located on opposite sides of the Wrench indicate the orientation of the sprinkler frame arms. NOTE Push up on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the spri.nhler wrench f1ats. Carefully remove the Sprinkler Wrench by disengaging it from the sprinkler wrench flats, and then passing it sideways over the sprinkler deflector. FIGURED SPRINKLER WRENCH SELECTION AND USE PSN 57 -XXX -X -XXX I TEMPERATURE RATING 135 135"F/5TC 155 155"F/68"C SPRINKLER FINISH 175 175"F/79'C TYPE 1 NATURAL BRASS 200 200"F/93"C 571 PENDENT 4 WHITE POLYESTER 286 286"F/141'C 570 UPRIGHT 9 CHROME PLATED 360 360'F/182T TABLE B PRODUCT SYMBOL NUMBER SELECTION 1/2 INCH ORIFICE MODEL A PENDENT AND UPRIGHT SPRINKLERS WITH 1/2 INCH NPT CONNECTIONS WARRANTY Seller warrants for a period of one year from the date of shipment (warranty period) that the products furnished hereunder will be free from defects in material and workmanship. For further details on Warranty, see Price List. ORDERING PROCEDURE A Product Symbol Number (PSN) is not specified when ordering polyester coated Model A Sprinklers with other than a white color; when ordering color coated Model F700 Recessed Es- cutcheons with other than a white color; or, when ordering sprinklers with thread connections per ISO 7 /1. It is suggested that a color chip be pro- vided when ordering special color fin- ishes. Otherwise, responsibility for du- plication cannot be fccepted. ' Contact your local distributor for avail- ability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify tempera- ture rating), Model A (specify Pendent or Upright) Sprinkler with (specify type of finish), PSN (specify from Table B). "Special Order" Sprinkler Assemblies with ISO 7/1 Thread Connectio11s: Specify: 1/2" orifice.i'(specify tempera- ture rating), Model A (specify Pendent or Upright) Sprinkler with (specify type of finish) and with thread connection per ISO 7/1. Recessed Escutcheon: Specify: 1/2" (15mm) Model F700 Re- cessed Escutcheon with (specify fin- ish), PSN (specify). 112" (15mm) F700 Chrome Plated 1/2" (15mm) F700 White Color Coated .. Sprinkler Wrench: ... PSN 56-701-9-010 . PSN 56-701-4-010 Specify: Model F850 Sprinkler Wrench, PSN 56-850-4-001. WEIGHT The nominal weights are as follows. 1 /2" Orifice Model A Pendent Sprinkler 2.2 ozs. (62 g) 1 /2" Orifice Model A Upright Sprinkler . 2.3 ozs. (66 g) 1 /2" Model F700 Recessed Escutcheon ; . . . . 1.2 ozs. (35 g) Model FSSO Sprinkler Wrench .... 1 . 15.5 ozs. (440 g) ®Reg.trademark of GRINNELL CORPORATION, 3 TYCO PARK, EXETER; NH 03833 A 1:lJCO INTERNATIONAL LTD. COMPANY