HomeMy WebLinkAbout2663 GATEWAY RD; 101; AS100138; Permit10/10/25, 12:23 PM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: AS100138 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS100138 2663 GATEWAY RD Status: ISSUED SPRINK Applied 11/2/2010 2131912600 Approved: 11/2/2010 0 Issued: 11/2/2010 Inspector: CHASE BANK STE. 101 Owner: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY LNR CPI BRESSI RETAIL LL C C/O LNR PROPERTY CORP 4350 VON KARMAN AVE #200 NEWPORT BEACH CA SAN MARCOS, CA 760-310-6122 about blank Fees($) 130 Add'I Fees ($) 0 Total($) 130 Balance($) 0 1/1 SUBMITTAL SERIAL N0:2932HY7 CHASE BANK T.I. BRESSI RANCH PROOF CALC .10/1500 FLOW TEST RESULTS Water Supply STATIC 52.20 PSI RESIDUAL 50.40 PSI @ 1065.00 GPM CITY PRESSURE AVAILABLE AT 341.5 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 100 40.59 40.00 8.00 101 40.57 40.00 8.00 102 40.14 40.00 8.00 103 40.12 40.00 8.00 104 40.02 40.00 8.00 105 40.00 40.00 8.00 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 10 TO 100 GPM 51.98 PSI PRESSURE ___ .,. ____ 25.74 25.72 25.18 25.16 25.02 25.00 241.45 GPM 100.00 GPM 341.45 GPM 50.41 PSI 0.00 PSI 14.22 FPS 11-01-2010 PAGE 1 SUBMITTAL SERIAL N0:2932HY7 11-01-2010 PAGE 2 CHASE BANK T.I. BRESSI RANCH PROOF CALC .10/1500 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 15 105 1.080 L 9.00 C=120 PT 25.00 (105) Q 40.00 F=T,E F 11.00 l?E -1.73 AO T 20.00 0.4071 PF 8.14 13 15 2.203 L 16.00 C=l20 PT· 31.41 15) Q 40.00 F=O F 0.00 PE o.oo BN T 16.00 0.0126 PF 0.20 PT 31.61 13) ------------------14 104 1.080 L 9.00 C=l20 PT 25.02 (104) Q 40.02 F=T,E F 11.00 PE -1.73 AO T 20.00 0.4075 PF 8.15 12 14 2.203 L 16.00 Cal20 PT 31.44 14) Q 40.02 F=O F 0.00 PE o.oo BN T 16.00 0.0127 PF 0.20 PT 31.64 12) ------------------13 103 1.080 L 9.00 C=l20 PT 25.16 (103) Q 40.12 F=T,E F 11.00 PE -1.73 AO T 20.00 0.4094 PF 8.19 11 l3DQ 40.00 2.203 L 16.00 C=l20 PT 31.62 ( 13) Q 80.12 F=O F 0.00 PE 0.00 BN T 16.00 0. 0457 PF 0.73 PT 32.35 11) ------------------12 102 1.080 L 9.00 C=l20 PT 25.18 (102) Q 40 .14 F=T,E F 11.00 PE -1.73 AO T 20.00 0.4098 PF 8.20 10 12DQ 40.02 2.203 L 16.00 C=l20 PT 31.65 ( 12) Q 80.16 F=O F 0.00 PE 0.00 BN T 16.00 0.0458 PF 0.73 PT 32.38 ( 10) ------------------11 101 1.080 L 9.00 C=l20 PT 25.72 (101) Q 40.57 F=T,E F 11.00 PE -1.73 AO T 20.00 0.4179 PF 8.36 9 llDQ 80.12 2.203 L 15.00 C=120 PT 32.35 11) Q 120.69 F=2T F 23.20 PE 0.43 BN T 38.20 0.0976 PF 3.73 PT 36.51 ( 9) ------------------10 100 1.080 L 9.00 C=l20 PT 25.74 (100) Q 40.59 F=T,E F 11.00 PE -1.73 AO T 20.00 0.4183 PF 8.37 • SUBMITTAI, SERIAL NO:2932HY7 11-01-2010 PAGE 3 CHASE BANK T.I. BRESSI RANCH PROOF CALC .10/1500 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 l0DQ 80.16 2.203 L 15.00 C=l20 PT 32.38 10) Q 120.76 F=2T F 23.20 PE 0.43 BN T 38.20 0.0977 PF 3.73 PT 36.54 8) ------------------8 9 4.316 L 10.00 C=l20 PT 36,50 9) Q 120.69 F=0 F 0.00 PE 0.00 FM T 10.00 0.0037 PF 0.04 2 8DQ 120.76 4.316 L 49.00 C=l20 PT 36.54 8) Q 241.45 F=0 F 0.00 PE 0.00 FM T 49.00 0.0133 PF 0.65 1 2 6.357 L 14.00 C=l20 PT 37.19 2) Q 241.45 F=2E F 22.68 PE 6.07 FR T 36.68 0.0020 PF 0.07 0 1 6.134 L 270.00 C=l50 PT 43.33 ( 1) Q 241.45 F=T,4E/2EE,DDC F 94.28 PE 0.00 UN T 364.28 0.0016 PF 0.58 6 II AMES 4000S8 6.50 PT 50.41 0) ii . l'"" ~ • ID . .. ~ • j ., iii ii f1 IJ af If Jf I I Jf I I Ja fi I J fl I J I ii II ~ i 1-II f i ~-II II 11 II ii II ii 11 • 'I .. ! li1II nu IIU 1(11! llli IIU I • :,, Hi • 1 • I ~, . • .. I i I I ., j .. ., I l I it~ . ., ., -u • . . . • _, ., ., ., • • ., . ., :! .. ., --.. u ., - a; 11 11 JI I I JI I I 11 I I 11 JI I I f1 11 I 11111 1111 1111 1111~ -t I 1111 illl f TlJH IIU Hli 11111 ll!i Hli • ~!,~ ~sl • .. ! Ii I I i p f I l I f ! ! ~ I I J i I ! I t I ! I ; I ~ . . . . ' g I -X I S-; ! ti !i ! I I ~ ~ ~ ~ 1 ... "' ~ • 1i • i i f ( ft ti I I i 1 i i 11 ! ! ! ! ! ! ! ! t -II ii ! i s • Ii i ) 'tqca I Fire & Building / Products Tec:hnbl s.tvloN: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-B -s;o K-factor Extended Coverage (light HazardJ Pendent and Recessed Pendent Sprinklers General Description n. SeilN Ee.a Exllnditd Cwerage Ptindent SprinlQera are decoratl'III glaa b!A aprlrti9rs dellgned lor UN In light hazaRi oocupancl8I. They are inlllnded ror iae ln automa1lc aprinldar systems designed In accordlnce ..,_ standard installllllon NIN (e.g., NFPA 13) klr • fflllXlmum oovenige .,_ o1 400 fl2 {37,2 mZ). A-compaq,dlo Ille maximum coverage ...._ of 225 aa (20,6 m2) for slandardcowni,a sprh-~ WNd lnlighthllZanf occupanclu. The recessed _..Ion of the EC-8, In- aided for UN In llr9aB with a finlshad c.1(1111J, t,aN .ithlr 1M two-piece SM! 30 ot= o40 RIICNNd &culct.on. The SMe 30 ReceaNd Escutclleon p!O-vldes up lo 1/2 lrch.ft2,7mm) oltotal f4ullrnenl from ltie ._, pendent po- ,11on, wt.1'11118, ... Styla 40 plO'lldN 31-4 Inch (19, 1 mm} cf wrtlcal adJUlt· men! from .. flllh pencw,t poeltlon. The adjustment pnM:led by 1he Re, ceancl Eacuteheo .. IUIC88 the ac-curacy lo~ the ftmd pipe ~pa to lhe apmklere must be CUI. Con'OslDn rnlfltarrt coating&, wtiere applicable, are utlbed to liDlend the Ille ol copper 1110v sprinillell beyond that which woukl olhtrwln be ob-tained wllen. eicposed lo corTOliYe at- mosphefff.. Allhough Wfl'Oli:)n mis• --AIW•Y• ,,,,., to TIM:lmfcal 0.ta 51»6t TFP700 tor,,_ "INSTALLER WARN/Mfr that prrw/d,16 caWMI Mffl ,npftt fo handlktg and lnal-latloncl lfPrlnld#.,.,_. _, _ p,onem. lffl/JfflPIK handing and~ Alltalon -~ dlltnage • sprlrlder a)WIMI or Its C!Off¥)Cl-11111nf1Jattdcac.. tn,, ,ptfrldt,rto faJI ti openll,/tla hdflM!lon«cause II lo opc1raflll pnmaturely. ..... 1 .,. tantcoatedspmlclers MWDUNdh nmdard com111lon IHtil ol tha ~ cable appnwafag,enclN, tie IMIIIQIB not rep1'9Mntatlllll a, all l)l)Nible CO,• .... almolpherN. Conuquenlly, It II ,-,unendld that .. end UIWbe COR8IAM:I wllh reepectlo1he 1ullabllty of hN corrosb, rnllllnt coatings br any (liven COl'!Ollw ll'Mn:inment. Thi alllcts of ambient temperature, concentration ol chemlca:18. and gukhemical veloclly. should be eon--lideied, U a minimum, along wtlh h COll1)$lya n&1ure of tha chemlcal to which th!t •Prinlcists WIii bl Sllp,t,Md. .,,_ = ==In c:::c ~d alld maintained Jn compll-anoa wfth lhls documed, • -.R ff lrithlhe~fllan:Jsfflsollhe NlllloMI RN P/OIJJction Auoc:wlion, In addition IO lhe 8tandal'm ol .any other .IUlhorltlH N\lfng /Urf6dlCIJOn. Fdul"llOdoMJ1Mylntpalrthep,,t- ~otfll-~ Th9ow,wrl, r«JPO(ld,lsfa(maJntaln-..... ,..__,.,..,..,., ... w;,n In propflf ~ (:MdlliOn. n. ~ oontraai:rarsprltlld,N" ,ruanutaduf8t should be contactfld Mfn any qlMtlons. Model/Sprinkler Identification Number TY"232 • Pa"ldlftt, I.OK TY4232 la a r9deslgnation br C4232. JANUARY, :ZOOS Technical Data er.:~ l..lsled. FM and NYC Ap· proved. (Refer lo Table A br complete approval Information lncb:llng con-o-slon 198lltant s1alui. Thi approwl& 9"IY tu 1he 8el'Vlce <:ondlllolla lndl- e-.:1 In Iha Daslgn Crttarill MCllon.) llnJnMm Worting ,_ ... 175ps1(12,1 bar') Plp.ffll'NdConMCdorl $'41nch NPT Dlsctwp co.tflclalts K "' 8.0 GPMlpsi11'-(l 1S,2 LPMlbarl12.J TFP22> ) ) P ... zor• TFP2ltl -.... """""""'"'" :::= '~ Li"" """"'~""""""7 3·8Mlr,g~ 4·1116 2: s.-~ I 2-11r Saft a (5'.0 mm) 11 • Ddolc:a• 1/2'" •~llllll'O■ 4 ~ fl·ffll" ~ on Dlllllm>r. MAKE-Ir,! (311.!i rrm) **1'11»"'-5 ~~s• 00-- FIGURE! SERIES E04 (TY.un) EXTENOED COl'ERAGE PENDENT Sl'fflNKLERS IPIWtKURFaall(a..Nalt4} ........ "" ..... .... NATIJIIAL 1-~-UQUID IRA8S PI.A11!0 YD"'lml """' ---°'""' -""' 1.2,3.5 ....,laTllll98b" ULandc-uL --............ '"'"'"""" °'""' .. .,.,...&A. ,...,,...., ... 1,2,3,5 fw.rloT.w.Cb"FII --............ ,.....,.., """" .,..,.. .. &A. -... t,2,5 ..... , 1.l.llMllf' Llndentrlllrs Ult>Gr-.iorln, Inc:. (IA.). Z.U.011', l.lndenrml9nl Labaral.arlllOl, lnc.1Dr...-nCanadll(C,UI..I. 3. "411,r°"'9d II', FaclOl'y MLAIII RIINarch Carparalkln !FM). 4. Whe<9 ~• C°"'9d Splt,lder8 _,. nota:110 lie UL and C-Ul. Usled, !he aprWars Ml UL and c.uL. LIited as Corrwlon ,.. __ S. ~ II', lhe City Cl! New Ycrk ulldef MEA 113-04-E. •Frr,me andDellector only. Llltlnosand apprwals ~ 10 color(Sp9cl&rl c:>n.r). ,._perabn Ratlnp 135"F/57"C and 155°F'6B"C -SptWder: Reier to Teble A RICIIHd Eseu1cheon: While COated, Chronw Plated. and Braas Plated Physical CharecleNlic. Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . . . . . Bronze ~-':'=ixii Niekeiwir~ Bui) • • • • • • • • Glase (3 mm Ill.) Compraaelon Screw •.•..••.. ..............•. Bf"onze Oe1leclor •••• ·•·••···Brua t Reglsteted tradernanr. of DuPont TASt.EA LASOAAroRY USTWGS ANO APPROVALS ~la"'-D-,,,nel'llfflls.ctlon} Operation The glllllS bulb mntalna a fluid !hat lll(p8flda when npoudb hut. When the laled lemr,eraklre 1s reached, the lluld eiq,llll(tl sufflclenlly b •hatter the glMs b!A, llilowlng the sprtnkter to aetlvale and flow-tar. Design Criteria ~~~ex::~ staled In ICCOfdence wllh the appllca- bii, UL end C-UL l.lltlr,g or FM Ap- prou.i requlremanh es Indicated below. Oliy the Style 30 or 40 Re- ceesed Eecia:heon I& to be used for recessed lnstalatlon, u appllcable (Rel. Table A, B. and C), UL and c--ul Lllttl'lf __ ... 1. The &Mies Ec-e Sprfnk$a111 may be Ullld lorh lXM!ragB anw snown In Table 0, bMedcnmelntMWlglha rnri'tlum tpecllisd low ra1a as a lundlon (If COV8l'8Qlt IUU. and Im:· artf \'IIVIJP for ad of 111a: sprinklers In ... __ 2. =-~:=.~~ii!: with WIObstNclilcl constNcllon GOn-atlrlg of llat. snool1 celllngs (i"\- ckldng bar )Oilts) wlh a ll'l9Dlllffl pllch of one In m aa dBflnlld and pennllledtr,NFPA13. 3. The minimum allowable~ be- ) TFPZ23 ,,.., , .... .... SME 1h18 Pendlnt OR "" 1h: 11 6tlle :,0 Alll:aled QR OR 1&x11 Sl)W40,___ QR QR 111111 Ptndanl QA QR 1&x 11 Slyle 30 ,..__ QA " 18x11 Slyla4011..-1 QR " 20 K20 Pendent OR " 20x20 81)1,,30Fleoaled OR " 2Dx20 Slyla40A«aeed " " QA:QulclrRelpc,!N SR:~IIMpurM ft'A:Nol~ TAIIUB &EHSl1MTYRATING FOR UL AND c-Ut. l.lS71NG OFSERIES Ee-I SPRINKLERS ,,... , .... -mt.E 16.-1& Penitent OR "' 18 x 1l ~ 30 Aill0el8ed QA WA 16 :dt S¥e 40 Ra:eaecl WA WA 18 x 1l Pendant QR Q' 18':18 8'4930~ OR WA 181118 Style30~ WA NIA 20x20 Pend9rl QA OR 20 1<20 61'/1930A9ceald QA NIA 20 X 20 Slyla 40 RacOICled WA WA QR;QulclrRNp01118 SR:Slanda!d~ WA: Nal Applcablt TAIIUC SEIISIT1WTYRATWG l'OR FIi APPROVAL OF SERIES EC.. SPRINKLERS tw.nthe Serial EC-&Spmldenl, ID prws,1 co1c1 90lderlng, 1s a feet (2,4 m). ._ TheSerlee~Spr1nlcl8ll;a191Dbl Nllllld~acc«dancewllhalollwr ~ of NFPA 13 IDr ex• tenclad coverage pe,ndant aprln- -· :C..."t:=. Thll Seri1s EC-6 &landed co-age Sprtntclel'I 1119 lo be inllalled In ac-cadanca with the applclble Factory ..._. LoN Prewnloft Data Sheet. lllmmatlon plOV!ded In lhl FM Loa PiwenlonDala81-tBNMteto,but =·: ~.:·~~~ mum and mulmum allowable apaclng, Ind deflector-lo eeiMng dl&tance. ..... ., ... Installation The 6eriN EC-a Sprlnidllf'II muet be lnstallld lnKCOl'dance wtththe follow. Ing hstrucllons: NOTff Do not Install any bulb p -,,rln/d«" lhe tub la cnu:nd or,,,.,_ Is• Ion af #quid from ,,. bulb. WIii! Im apt1nldM Mid hodzonlaNy. • llnd air bubble .tJOUldbeptNfld. Th81iantllNl'alllMJ air 6LOll{e 15 ~ t/16 inch (1.8mm). :?::.:=:::=:: ti 20 ..... (13,4 lo 26,B Nm). A fM»-llUII al so ft.k (40,7 Nm) al t«QU8 S It! be Wff 10 1"""'11 ,prl111tlars. HlghetifwMofb"QIICI maydat«tllle _,_,., "1let ll'lrfl llltHIHqUMt '-k· • O( tmp,drm,,nt"',,,. .,,,,._,_ Do not_,,,, lo~ tor ln-Nl'ldent~olanEscuttiwon ,,,.,. by under-Ol' ~ ,,. s,,rlrrld,H. ~ tl»pol1ltlon oflhe .,,,,,..,,.lltinglOltJlt. .., 1. The'fl'lltitrmultbalnmlled wtthtiedllleelorpatllllllllolhe mount• Ing aurlace. Pendlnl aprlnklars fflUBI be lnnllled In the pendent poaillon. 8lep t. After lnstallng the Style 30 or , 40 mounting plate (or ottiar HCUlch- eon, u appllcatlle) over the spl'lnkler pipe lhrNda, and wllh~pe thread _.rd eppled IC the lhreads, hand tJghhln the 1prlnk r Into Iha lf)rlnlNr filllnSI. 8lilp :I. Wrench tighten peodant sprtn-klll'I ulfng only the W-'fyptl 3 (End A) Sprlnkllr w~ Wrench tighten the reeel81d pend,m 1Prlnkler11 Ullng only the W-lypll 4 Sprinkler Wiwnch . TIii wrench racM8 ol the appllcabl9 l9rlflkllll"wren:h (Allf. Flguni 4 and 5) 181o be applkld ID Iha lfJffnkler wrench !lats (Ref. FigUf11 1). ) P ... 4ofl -TYGaZpc.u)PSmefT 1 IL•0.304llm 1112 .. o.093m2 1 gpm • 3.715 ~ 1 JIii • O.oees& b9r 1 QllffV'fl" • 40.74 IIWMm ,.., .. (12.7.a,2nwn) ""'"' -,.,,.,..., ~ ""'''" a.oouRE .... 18• 1'I 18xte "'" ... "' 28 10.8 33 17.0 .. "" 1-114"@1.&nwn] 1"(215,4mm) RGUREZ SERIES EC-a RECESSED PENDENT SPRINKLER ASSEM'BL V Wfflf nro-AECE 1/Z INCH TOTAL ADJUSTMENT STVU 30 RECESSED ESCUTCHEON ""'""' 314"j1Q,1 U4"{Ll,41ffl\) , .. :r ~] I 13/18"(20.8~ ,...,.., RReS EC4 ~PENDEIIF SPIIIIIKlBf ASSEMBLY Wfflf 1WO-l'ECE S/4 INCH roTAL. AOJUSTIIENT SJYLE 40 RECESSED ESCUTCHEON ) TFPZ23 "FITTING SIDE' TOWARDS SPRHK!.ER FITTING ?RENCH] RECESS END"A") -· W-TYl'E 3 Sl'RINKt.ER WRENCH - ft~5,-~ (i) __ _, : L.. i, <:::i@ : ____ ., ' .....,. """ -· W-TYPE-fRECESSED --- Care and Maintenance The SeriH Ee-a Sprlnkier11 must be maintained and NM0ld In acconj-ance with 1h11 foluwlng ln&tructions: """ :-.:=:1:.:~: MJtfc"onthellrepn:,lectJonl)'Sfem M II conm,is, ~ ta ehut dow,i the •ffecl«I ffAI ~n sysMmS =-t!:t.°!:!~'::-'°"ma'; be decled by thlll lldlon must be no--_,_ Sprtnldera !hat are tic.nd lo be lllll.kng or IIXhlblllng Ylslble llgns of eorTOtlon mUlt be l'lll)B)8d, Auloma1ic aprlnldera must -be :.S::iJ.~IN'Mg-=.:.i~= fled sprinklera must be replaced. Sprlnkle,$ Iha! have been exposed IC ' ) T ...... COl'l'Olllve productl of combustion, but t..not~.llhollldbertlplaced If hy camot be oomplalely cleaned by wiping the spn..._ with • cloth or by bruaHng It with a 80ft brilde btuah. Care muat be -.rciled to avoid dam-age to-1hfl apnnklln • be1or,, dUring, and lft« lnstalatlon. Sprlnklenl dlm- :: .. ~~"I;,, =-~~n: plllced. A11o,r9Ptaee..-,911rlnklllrlt'at t.s a cracked bulb or lhal has bat llf!kl fiom Ill tub. (Ref. lnalalation """"l• frtquent vialaf Inspections are NC· ornmended to be lnllially Pffl1)l'ffllJd 101' corrosion resistant coallld eprlnlders, _.. the-ln8tdatlon hM been com· plek!ld. IDwrffylhe lmtgrilyoflhe eor- roslorl INl&tant ocallng. n.r.fter, anrwal Inspections per NFPA 25 lf'lould IU!llce: '-'· lnsleal ol ln-~flom thelloo(klYII, atandom samplng of doff.up vt&ual npec- tc,na ahould be made, ao • to better dllermlne the elUlcl ,pmlder QCJl'ldl-don and lie long term lnllVltY ol Iha cor«Mllon iedclanl coating, ... may be affacied by Ille corroelve ccndlllons -"' The OW!lllt II JMpONibll br the in,, lpecllon, '"11ng, and maintenance of llllr firs proleellon ityatam and de- ricea In compliance wtth lhls docu-ment. a weN aa with lh& appllcable llandarda of the National Fite Protec-'°" Asaoclallon (a.g., NFPA 25), in llddltlon to Iha atandards of any IJlh&r aulhortt181 haYlrig jurisdiction. The ln- 11ding contractor or &prinkler manu• laciurer1houldbe contacledl'IU.tlva to .. .-. It 11 recommended thal automatic 1prlnkler ,y,tema ba Inspected, tested. and maintained by • (Jlallied Inspection Sarvlca In IICCOfdance with loc:aJ requll'9fflanl9 andl'or na11onlll ""'= Umlted Wan-anty Produete manutactured ~r: a.. Proctucls are warranted IO lo 1he orlglnal Bu)'11r for ten (10 years againlt dlfeca In material and work-manship when paid for Md prcpe1ly lnstallad and maintained under normal UM and Nrvlce. This ft!l'lnty wll P· p1111 ten (10) years from date ol ~ menl by lyco Fin Producta. No war-ranty 11 given !or prodwetl or aimponants manulllctlaed by compa- nies not aftllatad by ownership wllh TyooFINIPr:~~...-= ~ lmpiq,erln81d811on,corro- lion. or MIid\ have not bNr'I hBlallld, ::«'w11t11110dlfledor=9:t Ille National Fire PRnlCllon Anocla-llon, andfofllle standardll d Mt OChel" Aulhorilles Having Jurtldicllon. ,.... rlall t.xn:l ~ Tyco Finl f>!Odl.Jcig to be defeethe ahall be eltber 111palrvd or n,ple,oed, at 1yco Fire Products' llole option. Tyco Flre,-Products neither - 111n1&, nor authorbs any peraoi'I 10 -for it, a1PJ other oblipllliDn ~ connection with !hi ..re GI' pllClducta Of pa.rt& of product,, lp Fire Procb:ts shall not be responalbla for &prlnkllr =::'fmo~~~~~:; 8uyer or Buyer'a Npl'9lllltallvl8. IN NO EVENT SHAU TYCO ARE PRODUCTS BE LIABLE. IN CON- TRACT, TORT. STRICT UABUTY OR UNDER ANY OTHER LEGAL THE• ORV, FOR INCIDENTAL, INDIRECT. SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO U..BOR CHARGES, RE• GAROLESS OF WHETHER TYCO ARE PRODUCTS WAS INF'ORMED "80UT THE POSSIBIUTV OF SUCH DAMAGES, AND IN NO EVENT SHAU. TYCO FIRE PRODUCTS' LI· ABILITY EXCEED AN A.MOUNT EQUAL TO THE SALES PRICE. tflf R?BEGQIHG lffff84HTY ts M4Pf Ill l /Ell OF INY 4M2 41 l CZPWll'f8B4HI'ESFYPRES9?8 W!J 'fP WCI l!OPKi "4884NDF$ PE HfBGH1Hl4fW UY 4NP BI· NEV E9B 4 Pt1RDCCU 48 PUB· ,,,... ~•ot• Ordering Procedure Whlnplaclngenorder, lndlcatl1hlfull product name. Please specify the Sprinkler ldlntlllcl.tlon Number (SIN). ., __ .... ___ .... , 10 fie Price Ust tor complete llsllng ot Part Numblis, Contac:t your bc9I <btrlbulor lor ~ -SpmldlJ "--'bllN with NPT 1llrNd ConnecHons: Speclfy:TY-4232, (specify temperature =L ~i=Tri11~ (apedfy). -----••• •••·•••••l'&NSHOl•MS!i -Codd ............ Pst150«l1.+1'5 -fl,\UO'IO)" .• ······--1♦1S5 C11aM -• l'SN IIMID1+1S5 ....... --·· .PSNIIO«l1-1·1S5 wn..eo.ci ............ Pstl!Kl«l1.+1S5 -jFW.I0111)' ........• PSNSMD1+155 a-PWod .......... PSNeo,.aot+156 "Eadtfn~ ..... orly. ...._&cull:hNn: Specify: St)4I (30-or 40) Recessed Ealulcheon wilh (speclly flrnh), PIN -)-.,.. ___ _ aw.n. -............ P$H N-7US+O't 1 -Celor~ .•.•..• PSN 5lH~1 -,..,UOICl)" ....•...•• PSN.7ll5-3-011 -Plllad .......... PSN.705--2-011 .,.. __ _ a--............ l'&N.11»+-0'10 -CGID<c...lod ....••.• P'SNM-7ll0--+01P WIIIIO(AAU010)" •......••• PSN•Tl»-G--01o ... Plllad ............. PSNM-100+010 'Eanlm ~..,. tny. Bprlnldlr lft'lndl: Spec:lfy: W• lype 3 Sprinkler Wrench, P/N~1-001 Specify. W-lype ◄ RUC8&Sed Sprinkler W191\Ch, PIN 56-875-4-001 ) ) p ....... TFP223 TYCO FIREPAOOUCT8, 451 Morth ClnnorlA-. IAnld!IIII, ~ 1114-411 I 1:qc:a I Fire & Building / Products Tedlnlclf SerYlcN:Tel: (BOO) 381"'312/ Fax: jllOO) 791-5500 Series EC-11 & EC-14 -11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard} Upright, Pendent, and Rec. Pendent Sprinklers General Description The s,rtn EC-11 •nd EC-14 Ex-■ndec!Cotera,ge Uprtititand Pend&nl Sprinklef8 ani dacotallve gluB bulb' ....,_. deslg,Bd for 1,11e In llghl or ordinary hazard occupancillL They .,. lnknded for UM In automatic: sprlnkler sysllml dMlgned In IICCOld- in;:e wlh atandatcl Installation rules (e.g., NF!¥. 13) for a mexlmulTI OOYer• 191 arN d 400 ~ (37,2 m"), u com· par9d ti! h mulmum cowrage area of 1301P 112,1 m2)forl1andan:ICOWf• age tpllnldallil used In on:lnary haz· llfd occupancies or 225 ft2 (20,6 n,:l} br standard cwerags sp!Wden used In llghl tezard occupancies. The Serlff EC-11 and EC-14 Sprln-ldaf'S 1aatute a UL and C-ut. U.Ung Iha! ptrmlt1 their un With unot>- atructad or non•eombustlbkl ob- ltrUCted eeHlng conslr1ldbn u de- lMCI and perml!led bW' NFPA 13, u well as a specific appllcatlon n.tlng for UH under concnita lee8. The s,rier. EC-11 and EC-14 Ell• tended Coverage Sprlnkktrs have been Ira lelted lo compare lhelr per- formance !(I that of standard COVlll'a(lfl !r!:n~~~~~iwv: equal toor mon11 effee1lve flan ltand-ard cowraoe spray aprinkSllrs. --Alnys n,fer to Tee/In/cal Data ShHt TFP700 for It» "INSTALLER WARNING" that prrwldes calllllons ::.,~'i:.. ~~"::: po,w,u. ~ handl/rJg ar,d ln-stai.tlon can ,-,,,-,,tty damerQ6 • ~ ,ystem or II$ compo-lWH'b Mid C8U# 11w ,prtndsr lo fall lo opet11• In II lrs aifualkM OfC8llS8 II to opsnd& prema.fllfllly. ..._.tote Corroalon rasllltant eoallnge, where llrOOlii:able,-utlllzedtoaxlltndlhe lil9 of copper alloy lf)nl'lklerl. beyond lhat which would olhlrwlM bll ob-tained whan exposed to conoalw al· rnot,p11111"-Although eom:islon re.11-lanl omed sprinklers h9Ye puaed1he atandard COflUIIIDn 111s1a ol the appli- cable apprwal agencll!t. the leetlng Is not rep!Mffltatlwt of Ill posalblll eor- n:l8MI llllnoephel'IIB. Co~ntlY'. It ~ 1600i1w1.a1Kled Uia.t the and uaer be coneull9,j wtlh reepecttothe aullabllily of ltN.N COrfOlllon resistant coatings lor llnf glwn eonmlva envlrwment. The effects of ambient lemperatu«t, concentration o1 chemtcels, and gas/ehemlcal "nloclty, 8hould be oon,-aidered. as e mlrimum, along with Ille eormalve nature of Iha chemical to lmlct. ttw Sjlrinklers wll bl!I axposed. w-Thll Series EC-11 and EC-14 Ex- t.nd&d~Sprill/dBrldeacxlbed hllfllln muat be /nfla//fd end ma/n- m/Md Ill ~-wttfl this docu-~ u trell n with the appllcleJo standR/'$ ot the NatJoral ~ Prolei,- tlon Anoclf,/lofl, In addition to the llfllndsn:ls of any otht,rauthotflle, t,av- lflr, Jur(adctlotl. Fa/lunfcl do eo may lm,-Jr ,,_ ~ot ti!-.. ..... TheOlfflel'ls~formalnlllln- ln(J !hair 1/nJ p,otectlon 1)1111,m and de-vices In proper opMallng condillon. 1'hll liMWJino comactrx « sprinkler manuracturar shauld bf contactad llrithanyquntions. IEPTEllaER, 2004 IT /-~~~ ~~,ii: Model/Sprinkler Identification Number TYS137 • Upright, 11.2K TY&U7 • Ptnofeni, t1 .2K TYl137 • Uii,laht, 14.0K TYtl237 • Ptnd.ni, 14.0K TY5137 ls I rede8lgrotdion tor CS137, G1894, and S2510. TYS237 I& • l9deslgnation for C5237, G1893,andS2511. TY6137 le I redNlgnalion for C6137, G1S96. end 82610. TY6237 is a redesignldloo tor CS237, G1895. end $2611. TFP220 ) ,._..2ou , __ , __ 3.~_.....,. •--S-~-••-- •T ........... atiogil ----........ _pe,l60 m ..,, • ..,_ --- WRENCH FlAT ~• ... ESCUTCHEON PI..KTE II NPT SEATm~SU"""" 2-7/16" (61.9mm) -· J PENDENT 1-11/16' '._l I ,.._,_, ,12·,12.7rnm)T -~~i..Ll NOMINAL MAKE-IN --RGI/REI SERES EC-11 ANO l!C-14 EXTl:NDEDCOrERAGESl'Rl#KLERS 11.2 K-FACTOR (rY6'37' IJPRIGHr AND (n'anJ PENOENT 14.0 K-FACTOR (T"IB137' Ul'RIGHr AND (T1'82VJ PENDEIIT """" --- ...... • ,. SPRNKLER FNSH ISNNIIII>~_ ...,.,., I ,..,. I """'· '"'""" '-.I Ka~.!1_!:11JJf""" , ... ,...,, ,_., ""''"" ( AL)-CIIWii ..,,..,, ""-1oT.,.8fol' 286"F/141-C ...... .,.,_ --'"'""" ... .... ......., '""""" Rew tD Tabla C fol' 1Cio11.2(TY1217) "' .............. "'''"" _ ... ,. ---...... 'C -286"Ff141-C """""" '""""" Ka11.2(1'Yi127) ,..-.-c OR ..... , K-1,U (1'WIJ7} .., ,,..""" Fldtrto Tabla 8 lor ~1.2(T'\'5D7)1""" '"-""'""'---1 41-C ... Ra:..P&meNT 136"1'/57"C Rew to Tabla C for Ka11.2{1YllQ7) 165"Ml8-C .. Ka14Jl(l'YID7) ----· '"""""" ...,,..,, ..,,,., 1.1..lllad by Underwrbn l.abalalain:, Inc. (UL). 2..UIIBd by Undetwrlen ~. lh;. iarlllll hCllnldl(C-Ul.l, 3.Apprc-dbyf8cw.yMuwl"'"-aiehCorpordgn (FIi). 4.~ byfl9 City ofNN'Vo!l<undllrMu. 177-o:J-E. ...,, I ......... ....., ..... -... y--... -... y--... "'-... y----... ,_ - """°"'1 ........ 1 LOO PLATED r°"YEBYER! COATED 1,2, 3-,4 1.2,"4 1,2.4 f,2,3,4 , .. 1,2,4 1,2,3,4 1,2,3,4 1.2.4 1.2.4 ~, 6. Wher9 ~ Coat.d er I.Nd C..111d Spmkli,m -naiad lo lit UL and CU. Lllt9d. 11>9 9Pr1Mlem an, UL end C-UL Ulled 11 ConollonANtslanlSprinldem. ~...io.1111c1ororv,.~ar,i;1~~tocdoo-(8pKialOidilir). .. '"-ndl,n!Only. NIA: Nat Awlabllt TASLE A, LABORATORY UST1NGS ANO APPROVALS J ) ) ) TFP220 , ... aota ,...,..,. TFPUO """ ...... ,......,..,,.. ..... , ... , ,,..,. .... , ,.., ..... . .. ~ ,,.., ..~ _., .... mu 1◄x1<1 Up.orP9nd. -----'" '" ,. .. .. ,..,. 8,;1130Recellllld -----SR " ,. ,. ... 1◄x1<1 IIIVll40"'-------,. " '" '" ... ,e,.,e Up.orf>tnd. OR" QR" ... OR" ... '" .. • • .. SR 1h 16 Slylt30"'--! ... QR• ... • •• ... .. .. ,. ,. .. . 1h 18 8\41140"--I ... ... "" ... •• .. .. .. ,. ..A 18 X 18 Up. or f>9nd. ... OR" ... .,. QR• SR .. ,. .. .. Technical Design ample: obltruclonl to aprt,klat dB-charge, obstfuctlol'II to sprtnkler Data Criteria peni,m development, obltructlona m prevem 1prtnlder dllcharge rrom -The Serio EC.11 and EC-14 Ex-ru::hlng hazard, eleerance lo n,r- UL and C-UL LiBtlld.. FM AppttMld. illnded Cc:wenige Sprlnlder11 mual only _ ... (Re!erlo Tabla A for~ approval be IM.tallad In accordance with tt,e..,.. UL and C-UL ap.affll! Appladon lnlorfflllllon alClldng conoalon reall-pllcabla UL and c-uL Uatlng or FM =I Requlnm9nta For tant statue. The ~ apply to Iha Approval requirements n lndleated UndarCMctnTlff service condition&-lndlcllld In the De-below. Ony Iha Style 30 or 40 Re-TIKI Sirin EC-11 -~ EC-1◄ Ex-sign Crfllrlll IIICllon,J Cl8Hd Eleuleheon ii lo be U&ld for llndldCowrage Up~..,.-• llull'Mlffl Wofklng PIHall'9 rec:ieued installatlon, u appllcable Sprinldel'lil (TY5137, 5237, TY8137 175 p&i (12, 1 bar) (Ref, Table A, B, .nd C)._ & TY6237) have • UL lllld C-UL Spe- Plpa ThNlldConMctlon UL and C-UL Uttlng clllc Applklal:lon u.tlng for uae under --contl9le feel when lnltaled 81 fol-3'41nchNPT _, 1h11 _,..30"--d ... o,· QR• .,. QR• ,. '" '" .. ..A 18xl8 8""'40R--' ... NI. NI. NI. •• .. .. .. .. ..A ZOx20 Up.01Pand. ... .,. QR• ... ... SR '" .. .. "' 20x2CI 6'W30~ ... ... QR" ... ... SR .. .. .. ... 20•20 S1ylt40"-ud ... ... ... ... NIA SR '" SA .. ... OR: 01.fck ~ SR:SllndardRNpora NIA: Nd:Appl:llllbl,, • 0-r,ol oppt,, IO Upright K • 14.0 TABLES SENSITIVITY RA TING FOR UL ANO G-UL USTINQ OF SERIES EC-11 OR EC-14 SPRtHKLERS (SEE TABLE O FOR PERMITTEOK-FACTONAREA CO.VB#IA110NS} DIIIC ..... co.fflc'8nr. 1. The Serles EC-11 .nd EC-1◄ Spm-1. The 11111m11 o1 the concme ... con-K • 11.2 GPM,lpsill2 lclel'lil may be 1.-.:! lortlMt COVlll1IOI ~!1,i~/2 111'111111.tiownlnTIIDltD,b...ton llrucllon must lpeced at Ila lhln ~thlrin.rnspecllled 7.5 felt {2.3 m) on Oll'lllr but 11101e {201,6 LPM/baf11Z) lowlala••U'lelionofCOWl9fllllll lhln 3 fllllt (0,9 m) on oanter. The ---.... and hazard group for .. of1hl deptl ol thl oonolWteM must not ~ In Iha dMlgn 11198, IXCINd 30 t1ct1M (792 mm)-The 135"f/57"C kl 286"f/1◄1"C maximum permitted cone,.. IN ..... 2. The Serln; EC-11 and EC-1◄Splln-llllglh ii 32 felt (9.8 m); however, Sprlnlcl9r:Flefwlo1'aol9A kllll'IJ -pa,rmlted lo be I.Md with whlnl Iha COl'ICl'HI llee lengtl llll• R.-ed Eacukheon: Whllll Coalad, Ulklb&trucled or non-oombus1lble ceD32 fNt(9,8 en), non-corTtlu5- Chrome Plaled, .nd Bniu Plallld obllNclld a,a,g ~ .. .. ballet, equal In height to 1hl detlned and permMld b)' NFPA 13. .., allhe leel, can be ll'lltllll9cf 10 Phyak:a1Cha.ac11ilolllc. ,.,_ llal 11'11 apace belween 1he WIS Frame-. . . . . . . . . . . . . Bnmze =._ not e)CC8fld 32 fNt (¥,8 m) In ButlDn . . . . . . . . . . . . . Bronze IJnoblnlCl8d, combustl,la or nan- """""""' --,,.., .... , 17S"F -.. ~ 13!1'F ,..., ,,.., -,..., --····--···· oombusttbla, celling coutrucllon 2. The spt1nl:ler ddaclooi are to be . . . . . Beryllum Nlctal w/Teflont wtlh a deflector lo oellno'loaf dect( BUib , , . , .• , • Gius (3 nvn dla.) diltanca-al 1111121nches (2510300 bcaled In a horlz.onlll plane at or Compre8111on Screw . . . . . . . . . -·· above 1 n:h (25,◄ rm,) bebW the , ..... , ..•...... Bronze bollum of 1hl concme 1e1 s1em1. ..... mu 1<1 x 1• Up. or Pand. -----'" .. '" '" .. , •• ,. 8\11130~ -----... NI. .., "" NIA 14x1,4Slyll,40AecNNd -----... WA .. , NIA NIA 1&xt8 Up.arPend. ... .,. "' ... .., .. SR .. SR .. 18x18 Slyk,30"--OR o, ... '" •• NI. .., ,,. "" .. A 1h18 6\119.-0~ .. A ... ... ... •• ... ... ... '" NIA 18x18 Up.orf'ltnd. ... .,. ... ... •• '" .. '" '" , . lh 18 Slyil 30 AeceA9d OR •• "' .. , ... "" .. , ... ... .., 1h 18 Slyl,,<IORaceued "" .. , ... ... •• ... .., .. , ... WA 20 x 20 Up. or Pend. ... .,. "" ,,. ... '" '" "' " ,. 20x20 8r;ll30R--.d OR •• NI. .., ... NI • ... '" ... ..A 20x20 Brt'll40Reclued '" ... ... .., ... NI• ... .., ... ... QA:QlttRelporwe SR:~Reaporwe NIA:NCil~ ....... ""' T...._.C SENSITMTY RATJNG FOR RI APPROVAL OFSERIES EC-11 Off EC-1,f SPRtNKl.BfS (BEE FM LOSS PREVENTION DA TA SHEET 2-IN FOR l"EJflllTTED K-FACTORIAREA COIISINA TJONS) Oeltector . . . .. . . . . . . . Brass ObalJuctld. n01.-co,1b1ettbil, cell-3. When "'8 ll)Mkllr ddeclol'II ara Ing constn£tion wf1h a deflector b--.... callon below ltrucual ~ al =~.T:n;t!:"~ 1 to 8 lncl'II& (25to150mm)anda U.S.A. Patent Nimbers 5,368,022.; m&Jdrtum ddaclor 1o oelln;lroof bollum of Iha cm:t8lit IN dams, 5,579,8◄8"; 5,58◄,34◄; 5,609,211; dick clslanOI of 22. lndlel (560 1ha ob1tructlon lo sprinkler dis-5,862,99◄; and 5,885,258. ,m). =,r;3c~:,~u::9ra:;! Operation 3. TheSeriNEC-11andEC-1◄Spm-IV1llPrHcler9applaa. '""::::'Cbeenlpecllicalyllllllild The glah. tub contains a Md whk:h andlllad 1101-IAl!bleob-FIi- eocpands when e,cposed to heat When slruetld cor.truclon 111'11 permbd Aaqulluta•nlw Ille rated temperature II reachad, 1ha to be UNdwWllntn.Norblr Jo11it1 The Serlea EC-11 and EC·1◄ Ell· lluld expands IIJfflcianltylo lhaltarlhe hawing non-eombustibl8 web ~ llnd.td Cowraga Sprlnklara are lo be glaa8 bulb, which !hen alow8 Iha lplin• berl gr9lder lh8n 1 Inch (25.◄ IIW'i'I) ~IM:Ol~ :p:..-=:; kier to activate and flaw waler. -~tha ◄ timal ot:.:ruc-llon crilerla dellnad unmr "Ob-Data Sheet b' llmlted UN In bulclnga: 9'ructlonl to Sprinkler Olrictlarga ol apeclll,;; l'tlOf conatruetion and lor1ha ---=otec:tlon ,A oertaln specific ordinary (oo-:_ard'or non-flam• 4. ::.~~~:m.~ mabla or combust llquld) occupan- cles. Information provided In lhe FM Sl'fWdal'lil, to pnyent oold IOldlr-Lou P~n De.la St.els relale1o, ~,il81eet(2.◄m)foruprighll1Prin-but an, not lmltild lo, t¥:irmlc dalgn, klan: and 9 feet (2,7 m) lor pende,11 callincJ dope and obelructlorw, miN-........ nun .ct mu:tmurn allciwatN apac-Ing, and dallac:tJr-lo GIiiing ~ 5. TheSarieB EC-11 and EC-1◄ Sprln-Thaae criteria may differ from UL ldarl aN to be lrwlalad In aa:ad-anator NFPA crllarle., theretor. the de- ante wHh al olhar ~ al =~=:!'::1! =~=~: mente bltlore procee<lng wl1h design. TFPUO """"" 1-318" (34.9 mm)I t-1/B" (28,6 mm) SERIES EC-1 f AND EC-14 RE.CESSEO PIENDENT Sl'RINICLER ASSEIIIIL Y wtrH TWO-PIECE 1/Z INCH TOTAL ADJUSTIIENT STl'LE IO RECESSED ESCUTCHEON FACE OF SPRINKLER F!TTING 'i" CLOSURE ....... , 1/8' ~m) 1-:W' (34,9 nvn: 7/8' (22,2 mm) SERIES EC-11 ANDEC-14 RECESSED PENrJENT SPAfNICLER ASSEIIBI. Y WJJH J'WO-PECE 114 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON ) .,...,ate "FITTING SIDE' TOWARDS SPRINKLER F!TTING ?RENCH RECESS ENO'A1 ROURE4 W•TYPE 3 SPRINKLER WRENCH -m~-~ fr '1 (j) i ¢JG) / ' l--L_F, """"" ""' RGURE6 W•TYPE 22 RECESSED SPRfNICLER WRENCH ...... ., . .......,,.. TYS137(L11.2)UPMiHT TYl237(L11.l)PENDENT TY8137(Ko,14.0J WAIGHT TYSZS7 (lt-14.0) P!ND!NT 1ft.•0.304llm fftt,.OJJ113m' 1 ,apm., S.785 fpm 1 pel-o.o8l95 bolt 1gprrv'IP•«l.7•1111M111n ..... 14x14 16x18 18x18 """ 14X14 16x16 ,ex 11 .,,., 1<4x 14 tfixlll 18x 18 .,,., 14x14 tex te 18X 18 .,,., """'...,...., G.11Gf'IM'I" ... ""' ., ,, " ,., ., ,,. ., ,, 33 ., ., ,,. ... .. . ... ... ... ... ... ... -- "' '" " '" "' ., TABLED TFP22G ....,., ...... ORIJIUJIY HAZARD --· 0.11GPll/l'TI ........... ... "' ... "' "' ,, " 12.1 .. ,., " "·' .. 19.1 .. "·' "' ,._, ., ,,. i :w " 12.1 ( " "·' .. "·' "' ,._, ., ,,. .. ,. " ,,, .. ,,., .. ,,. ., , ... ., ,,_, ---- " ,. " ,,, .. ,,., .. ,,. "' "' ., "·' R.CWICRITERIA FOR UL AND C-UL UST1NG OFSl!RJES EC-ff AND EC-14 SPRINKLERS Installation The Series EC-t1 and EC-14 Sprln-- kler& must be lnllalled In llCCO!dance with the IDlowlng lnatructton.; .,,,.. Do not lnslall any bulb ry,,. spr/nklM II 1M bulb,. cradtfld or IN,. ls a lotra of ~ tram ltw, bufb. With ti» sprlnklM hsld horlzontalty, • small air bubble shouldbeprn«t. Tht,dametefdlh& ., bubblf, is appro,tlmataly 1116 Inch (1,6 mm) for lhlf 135"F/57"C lo 3132 Inch (2,4 mm) for the 2tWFlt4t"C -,np,,.flmtl'llt/n(I$ . A /rJak llahl Slf /nch NPT ,pr/nlclerjolm tJhouklbeabt111""'1with11~oftO to20ft.lbll. (13,4 ID26,8Nm). A fflllld-mum cl ao lt.bs.. (.W.7 Nm) ol torque Is lo be uud to lnirtllll sprlnlders. HighM lftwls oftorqwmay dlsbtlhlf ~ lni.t wfth ~ /Hk- 9 or ~otin. sp,Wder. Do not llll9n,,f to oompenute for fn-,u(flde,Jt~t In an Escttc:tw,on ::,n:,~::;~~= sprlnld,n titting IO lllit. Step 1. The 1Prinkler ffilllit be lnslalled with lhedefleetorparallel to Iha mount• lnQ auiface. 1'9ndent ip!'lnldeni mult be innlllld In thl!t pendent position, and uprlglll •Pflnki.ni must be ln-1!:dld In the upright poaltton. 8tap 2. Aflar Installing !he Style 30 or 40 mounllng plate (or olher neiAch-eon, u sppllcable) OWlr !he 1pmlder plpa threads and with pipe thread ...nt applecl to the pipe threade, hand llght:9n the sprinkler lnlo the aprllllder fitting. ,.,.._w __ "'"""",... dent lfll'lnkl911 ualng only 11\e W-l\'Pe :CEnd A) Sprinkler Wrench. Wrench ten the l'8C88l8d pendenl aprin-Ullng oolv lhe W-Type 22 Sprin-kler Wrench. The wrench l'8CIII of Iha applicable sprinkler wrench (Ref. Fig- ure • an:I 51 le to t. applied to Ille gprinldar wnmchtlats (Rel. Flguni 1). • ' I '>_ C ) TFP220 care and Maintenance The S9r1N EC•11 1111d EC-14 Sprin- ktars mu.I be murtained and serviced in accordance with the followlng In-.-, NOTE &tlor&doslngahprolacllon,yn,fl'I msln contrrJJ valVt' lor malnttJnanc» wort on thtJ flnl pratecllon 9yst&m llllt ltoontmls, p«m/akNI to shutdown 11w llif8ded fire protlldiofl syn,ms must t» obtained from the propN aulhorl· tin 1111d 1111 petmn(IBI who may bit d9cledbyltuaeflloomustbenotlfifJd. Sprinkllts that.,. bund lo be leaking or uhlbllhg Ylsi>le slgn9 of eorroslon nwt be replaced . Allliomatlc aprlnklera must -be ptlnad, Dialed. coatld, Of ottiarw111 illlHlld lflar klaollng 1h11 ~ Modt. Had sprlnlda111 must be replaced. Sprtnlderli 1hat ,-bNn expoHd to com»lve produt:19 of combUlllon, but :.-~ia:-=r:= by ~no u. tprtr...-wllh a cloth or by brushing It wl1h a mt brlllla btulh. Care m1J81: be exerolsed lo INOid dam-age b1he lll)rinl4ffll • before, di.Iring. and llflar lnatalallan. Sprinklers dam· aoed by dropping, Itflklng, wrenctl M~llllppag,e, Of the Uke, mull be !$- placed. Aho, leplaca llll'fspmldarthat hu a eraekad bulb or 1tiat has lost iqUld mlm 1t11 bulb. (Ref. ln&talla1lon ......,,_ ~"'::.~rtoi~ted~ eort'IJ81on rMls18nt coallld sprlnk1ers, aller tl'e lrmtallallon nm been com- pleted, to -iiy lie lntegttly of the cor-roelon rniatanl coating. TherNfter, annual lnapectlona par NFPA 25 should llllfflce; howewr, lnstnd ol ln- fll)eCllng ll'om !he flool' level, a random sampling of dole-up vllual lnapec- Vons should be lllllde, so llll to better detemlN 1he exac1 aprlnlder condt. lion and the long arm Integrity ot the COff'Olllon n11111tant coating, 18 II may be llfla:tecl by the corrostw 00ndftlon1 ........ Thi OWl'l9r III responalble for the ln- apection, flllting, and maln'8nance ol Mr fire protacllon syAllm and di,. =i:.~w:== slllndalal of the Nat1one1 Ani PIOl9c-llon Asloclatlon (e.g., NFPA. 25), In addillon to lhe atand8fds of any ottler aulhDrities having Juriadicllon. Th8 In- staling conb'aal)r-ot-apriMler manu- ladurershouldbeCOIUCl9dl'lldYeto ""'-· It is recommended tllet eutometlc sprinkler systems be inepecled, lffted, end melnlalned bye quelilied lnlpectlon Service ln acconiance wtlh local requirements and/or natlonel --- l.lmited Warranty P ... 7Dfl ProduCIIJ manulac:tured by Tyco Are Producla are wan-anted solely to the original Buyer for ten (10) yaar■ again.I ddcta in materifll and won(. manehlp when paid tor and properiy inlnlllMI end maintained \A'lder normal UH and l«Wle, Thia -naflty wll ex-pire ten (10) years from cte.11!1 or ahlp- ment by lyco Fn Prowc15. No war· ranty II given for producta or C0111ponenta tnanufaclured by cornpa- niN not affllated by -hip with 1yoo Aie Pnxluc19 or for products and oomponente which have been &Wjecl lo misiae, Improper lnllallirtion, COITO-slon, Of' wtlich have not beell installed, fflllintlllned, modified or ieD&irN In ac-COl'darloe wllh lPP(loable Standludsol the Nationld Aie Protadlon Assocla· llon, an6'or !he stendards ol' any ott.r Autllonhs Having ..uisdlction. Mala-ria found by Tyco Fn Produl;:ts lo be defecllva shal be alit.-rapalnld or ~. ;~ ;top~m:,-: ~-=~~: connection with 1h11 sale of product& or parts of products. 1yoo Fl,. Producls shall not be responsible lot' sprinkler syslem deelgn em,rs or inacc:ura,te or Incomplete lnlor~tlon supplied by Bll)'Bf or Buye(s reprnenbttlvaB. IN NO EVENT SHAU. TYCO FIRE PRODUCTS BE LIABLE, IN CON-TRACT, TORT, STRICT UABIUTY OR UNDER ANY OTHER LEGAL THE-ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE• GARDLESS OF WHETHER TYCO FIRE PRODUCTS WM INFORMED ABOUT THE POSSIBtLJTY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THf EQBEGQING WIBB4HlY Ui #APE II' I 1£11 OF ANY 4HP 4' I OlfffSW4BBANDEl!EIPRFSSOB PffO WCflWINGIP884AmfS OE Hf8Ct£4Hlt'Bll UY 4HP BI· NEU EOB 4 N:RDCMI 48 PIIA· -. ) p ....... Ordering Procffure When placing an onter, lndrcale the ful product name. Pleate specify the Spmkler ldenllflcallon Number {SIN), quantity, and lllmperstwe ,.ting. Refer Iii the Price Ust for complete llellng of ---Coruct your local distrllulor Jor avd-,blity. Sprlnldlr AuemblM with NPT lh!Md ConnectSctnl: Specify: (speelfy SIN), (tpeclfy K-Fac- tor), (apeclty temperature rating), =Pendent or Uprwrt) Exlendld Sl)l'lnlffl with (tpecffy lln- h), (1pectfy-fromTableE,where -·· --:::r~1:io~wi:(~:: i&h), PIN (epectfy), Style 30 Rec:eesed EscuEheon Cllnlmo-............ PSNN-7D5+011 WNloColoree.Md .......• .,.____,, WhlojRA\.II010l' .......•. PSN-,1 --·········· .. •·--•011 S¥9 40 Receesed Escuteheon Clvo,no l'w.,t ..•.•.....•. P8NS.-7!l0+010 -ColorC-,,., .... P8NS.-700-+0t0 -(Ml.91?10)' ••••••••• PIN S.-700+010 -Plillld ••• ,.. • ••• P8N M--.o10 "Elnlm Hemlsphe(e 1a11e ONJ. lprlnlder Wrencfl: Specify: W-l'fpe 3 Sprinkler Wier.eh, PIN 66-896-1-(101 Specify: W-"fype 22 Flecened Sprin-kler Wrench, PIN 5$-$5-7-001 PIN 51 • AAA-B -C:CC AAA • 893 (f«TY5237 K11.2 Pendent) MA•894(forTYS137 K11.2 Upright) MA• 895 (forTY8237 K14.0 Pend9nl) AAA·• 898 (fOrTV6137 K14.0 Upright) B .. 1 (tor Nelural Brul) B•3(tlr~ [RAl..9010])" B = 4 (for~ P°'fN!er) B = 7 (for LAd co-d 8 • 9 (forctwome Plalld) CCC• 135 (for 135"FtSrC) CCC a 155 (for 156'FJarC) CCC• 175 (for 17S"F/1'9"C) ccc-200 (for 200"F.93"C) "Eaalem Hamlllph8re aalss only. TABLEE PART NUMIIERS FOIi Ec;..11 ANOl!c;..14 Sl'fllNICtERS 1YCO fl'II!: PftOOUCTS, 451 Nor1hCamcnA-, 1.an1K111s.,..,..... 11M-4S ) TFPUO - Dyna-Thread· Full Line Sch-40 Replacement Dyn•Thffllld" offelS the life expectancy of St:h-40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 • Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. • Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. • The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. • The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. • The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. ® <8> (W Listed Approved Listed • With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Specifications NPS Namlull.D. WI. WI. (H20 Alledl Pcs/ WIJLlft (21') WI/Lift (24') WIA.lfl(Z&' ln;mm tn;mm Lbs/Ft; Kg/m Lbs/F!; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1051 1¼' 1.408 1.870 2.54 51 2002 2288 23& 32 35.8 2.8 3.78 51 908 1038 108 1½' 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114. 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103, Comparison to L.W.T. Pipes • More wall thickness at the thread (CRR-1.00) gives Dyna-Thread better life expectancy than lightwall tbreadable pipe joints. • Unlike lightwall tbreadable pipe, Dyna-Thread bas no thread gauge warning. • Dyna-Thread is approved for standard banger spacing ( 15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna-Thread is safer to weld on. • Dyna-Thread is more widely accepted than ligbtwall threadable where Sch-40 is specified. Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes ofSuper40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). 1:qca I Flow Control (.;.> allied 16100 S. Lathrop• Harvey, IL 60426 Customer Service: (800) 882-5543 1\JBE a. CONOUrT 11350 Norcom Rd.• Philadelphia, PA 19154 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3-3 ,--..., 8007957 GST 10 8020957 SWG10 8008957 GST20 8068925 GST20SS 8010957 GST30 8009925 GST 25-380 8022925 SWG 25-380 8021957 SWG20 8073925 SWG20SS 8139957 SH GST20 8141957 SH GST30 8140957 SH GST20 SS 8142957 SH GST 30 SS 8038957 DSTR 1 8037957 DSTR 1-1/2 8039957 DSTR 516 8045957 DST 516 8046957 TEK50 8055957 SWDR 1 8056957 SWDR 516 8054957 SWDR 1-1/2 8137957 SH DSTR 1 8150922 XP20 8153922 XP35 8059957 CST 20 8061957 swc 20 X X X X X X X X X X X X X X X X X X X X X X X X CPVC 1-1/2 300 CPVC 1-1/2 300 2-1/2 850 2-1/2 850 4 1500 4 1500 3-1/2 -4' 1500 2-1/2 -3" 1250 2-1/2 1250 3 1050 4 1500 3 1050 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 2 750 3-1/2 1250 ®s LISTED 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 ,. 0.035 0.035 0.037 0.188 0.250 0.037 0.037 0.037 0.035 0.027 0.043 X X X X X X X X X X X X X X X X X X X • SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" • .---..., •• SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1.5 1.5 1.5 1.5 1.5 1.5 0.1050 0.1050 0.1050 0.1875 0.1875 0.0600 0.0600 0.0600 0.1050 0.1050 0.1050 3000 PSI 3000 PSI www.itwbuildex.com 800-284-5339 SSS26 I MECHANICAL TEE The Shurjoint hole-cut mechanical tee provides a fast and easy mid-point branch outlet without welding. First a hole is cut or drilled at the desired outlet location. The mechanical tee is then positioned so that the built-in locating collar fits within the hole. As the housing bolts are tightened the pressure moulded gasket forms a leak-tight seal. Use of the Shurjoint mechanical tee can eliminate the need for multiple couplings and fittings. Shurjoint offers a full range of mechanical tees: Model 7721 Threaded outlet, NPT or B521 (150-7) pipe threads Model 7722: Cut-grooved outlet (machined) Model 723: Saddle-Let; Small mechanical tee with threaded outlet, NPT or 8521 (150-7) pipe threads MECHANICAL CROSS A mechanical cross connection can be made by combining two mechanical tee upper housing segments. While the housing segments must be the same size, the branch outlets can be of the same or differing sizes or configurations. 0¢0 Threaded X Threaded Grooved X Oroovcd Th,aded X Grooved (Model 1121+1121) (Model 7722+7722) (Model m1+n22) caution: Piping practices require that main and branch connections are at a true 90" angle. Also be certain that the locating collar is securely positioned inside the outlet hole before tightening the hous- ing. When mechanical tees or mechanical crosses are used as transi- tion pieces between two runs, the tees or crosses shall be assembled prior to making the branch connections. MODEL 723 SADDLE-LET (Small Mechanical Tee) The Model 723 Saddle-Let is the ideal outlet fitting for direct comections to sprinkler heads, drop nipples and or gauges. No need for welding, just cut or drill a hole at the desired outlet loca- tion Position the Saddle-Let so that the locating collar fits within the hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle-Let allows full bore _flow and is pressure rated to 300 psi (20 bar). 28 I SHTJRJOTNT®