Loading...
HomeMy WebLinkAbout4411 PARK DR; ; AS020102; Permit10/10/25, 12:21 PM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: about:blank Fees($) 190 AS020102 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS020102 4411 PARK DR Status: SPRINK Applied 2061924700 Approved: 0 Issued: Inspector: GAITAUD RESIDENCE Owner: Add'I Fees ($) 0 Total($) 190 ISSUED 7/19/2002 7/22/2002 7/22/2002 Balance($) 0 1/1 CARLSBAD FIRE ~E?T FAX NO, 7609280255 P. 02 CARLSBAD FIRE PROTECTION SERV~~" Permit Submittal Form 'JI.~ IF-If S (j}O/ D )__ A. Chc,k or fill in pertinent information for type of pennit you are ~ubmitting. AS • A utommic Sprfnklcrs • ,x--· Commercial_____ Residential ___ _ Number of l,\eads per Sy>tem: System #__l___ He.idsJf:J_ Sy~tem # ___ Heads_ System#_ Heads__ SyS!cm # Heads __ System# ___ He~ds__ S)stcm # Heads __ Undc:ground included for appro,·al -~===--- t.:ndcrground inch1ded for refrr~nce only ___ _ FA -Fil'e Al<Jrm l 0 devices or less Over l 0 dev:ces # of devices * Total Fees ! :1 0 ---- FS -Fixed Systems (Circle One) Hood & Duct, Halon, S;ecial Cbemical Agent, Standpipe, Sprey Booth, or Appliance. -··· Total Fees __ _ There JnilY bee an additional fee cfS50.00 rer 1/, hour for Failed Inspections. B. Address of job sit~-Y '-{ (/ -p fl {LK )) ru\lE Suite# __ _ ff; Building Permit# <.:B ~ /~ C Contractor Information t?'tl/ t~ ,e 6-7 /c/t::ac --e., ,t--,;L -/7 ;-.;ame IN I\) D v f\,~c 'f' 1~15" :f:e__o:::, TE CT7 ~,J Address~ D S V E:f2N tl J W 11\ Y City, State, Zip l~\.-C fu \\N Lt\ • Kind of License and number~lli] l I \ j ~ Phon{ G l U\ ) S lf '3 -i 2-(') 0 Certillcatc oflnsurance on file with Fire Dept,? ~r N Bu sines License n filr wi City? ~r N Signature J\J---r./J Date 1-\ 't> -"ti ':L SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 Date: 07/18/2002 Cl780SDF.SDF JOB TITLE: GAITAUD RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RES ID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 70.0 65.0 500.0 70.0 29.2 61. 3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 29.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 24.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 61. 3 29.2 2 a.a ----55.4 2A 0.0 ----42.4 3A 0.0 HOSE STREAM 40.7 5.0 3 0.6 ----39.4 4 3.6 ----36.6 5 9.6 31. 8 6 9.6 ----15.4 7 9.6 ----9.8 7A 9.0 K= 4.20 8.2 12.0 8A 9.0 K= 4.20 8.4 12.2 9 9.6 ----19.7 9A 9.0 ----19.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 Date: 07/18/2002 Cl780SDF.SDF JOB TITLE: GAITAUD RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) F.L./FT (PSI) Pipe: 1 29.2 1.025 PL 20.00 PF 5.8 1 0.0 SRCE 61. 3 (N/A) 11.4 150 FTG TG PE 0.0 2 0.0 o.o 55.4 0.0 0.194 TL 30.00 PV 0.9 Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 55.4 0.0 13.0 psi, 29.2 gpm 2A 0.0 0.0 42.4 0.0 Pipe: 3 29.2 1.360 PL 30.00 PF 1. 8 2A 0.0 0.0 42.4 0.0 6.4 150 FTG 3L PE 0.0 3A 0.0 H.S. 40. 7 5.0 0.049 TL 36.00 PV 0.3 Pipe: 4 24.2 1.265 PL 10.00 PF 1.0 3A 0.0 H.S. 40.7 5.0 6.2 150 FTG TL PE -0.3 3 0.6 0.0 39.4 0.0 0.049 TL 21.00 PV 0.3 Pipe: 5 24.2 1.049 PL 3.00 PF 1. 5 3 0.6 0.0 39.4 0.0 9.0 120 FTG C PE -1. 3 4 3.6 0.0 36.6 0.0 0.185 TL 8.00 PV 0.5 Pipe: 6 24.2 1.109 PL 14.00 PF 2.2 4 3.6 0.0 36.6 0.0 8.0 150 FTG 2E PE -2.6 5 9.6 a.a 31.8 a.a 0.093 TL 24.00 PV 0.4 Pipe: 7 14.4 0.874 PL 102.00 PF 16.3 5 9.6 0.0 31.8 0.0 7.7 150 FTG 7E4TR PE 0.0 6 9.6 0.0 15.4 0.0 0.114 TL 143.00 PV 0.4 Pipe: 8 24.2 0.874 PL 12.00 PF 5.7 6 9.6 0.0 1.5.4 0.0 1.2.9 150 FTG T4R PE 0.0 7 9.6 0.0 9.8 0.0 0.298 TL 19.00 PV 1.1 Pipe: 9 12.0 0.874 PL 8.00 PF 1. 9 7 9.6 0.0 9.8 0.0 6.4 150 FTG 3ET PE 0.3 7A 9.0 4.2 8.2 12.0 0.081 TL 23.00 PV 0.3 Pipe: 10 12.2 0.874 PL 7.00 PF 1.6 7 9.6 0.0 9.8 0.0 6.5 150 FTG 3E PE 0.3 SA 9.0 4.2 8.4 12.2 0.084 TL 19.00 PV 0.3 Pipe: 11 -9.8 0.874 PL 61.00 PF 4.2 6 9.6 0.0 15.4 0.0 5.2 150 FTG E2T5R PE 0.0 9 9.6 0.0 19.7 0.0 0.056 TL 76.QQ PV 0.2 Pipe: 12 0.0 0.874 PL 5.00 PF 0.0 9 9.6 0.0 19.7 0.0 0.0 150 FTG 2T PE 0.3 9A 9.0 0.0 19.9 0.0 0.000 TL 11.00 PV 0.0 Pipe: 13 -9.8 0.874 PL 180.00 PF 12.1 9 9.6 0.0 19.7 0.0 5.2 150 FTG 5E5TR PE 0.0 5 9.6 0.0 31.8 0.0 0.056 TL 216.00 PV 0.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Date: 07/18/2002 JOB TITLE: GAITAUD RESIDENCE TWO HEAD CALC NOTES: Page 3 C1780SDF.SDF (1) Calculations were performed by the HASS 6.6.0 computer program under license no. 16080621 granted by HRS Systems, Inc. 4792 Lavista Road Tucker, GA 30084 (2) The system has been balanced to provide an average imbalance at each node of 0.010 gpm and a maximum imbalance at any node of 0.120 gpm. (3) Velocity pressures are printed for not used in balancing the system. is 12.9 ft/sec at pipe 8. information only, and are Maximum water velocity (4) PIPE FITTINGS TABLE Pipe Table Name: PSS.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 1.50 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B Ell Tee TEERUN COUPLG EL45 0.874 4.00 3.00 1.00 0.00 1.00 1.00 3.00 1.109 5.00 5.00 1.00 0.00 1.00 1.00 3.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1.025 3.00 8.00 2.00 2.00 2.00 2.00 0.00 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 D 1.00 L 1.00 1.00 D 0.00 0.00 D 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Date: 07/18/2002 JOB TITLE: GAITAUD RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 72+ O*\\ \\ I \\\\ \\\\\ 66+ \ \ \ \ I * <-65.0 psi@ 500 gpm Flow Test Point X 60+ I 54+ I P 4a+ i I S 42+ : I 36+ i I I 30+ ) I 24+ I 18+ '============================== 12+ LEGEND I X = Required Water Supply 61.28 psi@ 29.2 gpm 6+ I O = Available Water Supply 69.97 psi@ 29.2 gpm Page 4 Cl780SDF.SDF O++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 Date: 07/18/2002 Cl780SDF.SDF JOB TITLE: GAITAUD RESIDENCE ONE HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 70.0 65.0 500.0 70.0 21.0 47.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 21. 0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 16.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 47.6 21.0 2 0.0 ----44.5 2A 0.0 ----31.5 3A' 0.0 HOSE STREAM 30.5 5.0 3 0.6 29.8 4 3.6 27.8 5 9.6 ----24.1 6 9.6 ----18.7 7 9.6 ----18.7 7A 9.0 ----18.9 BA 9.0 18.9 9 9.6 ----15.8 9A 9.0 K= 4.20 14.5 16.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 Date: 07/18/2002 Cl780SDF.SDF JOB TITLE: GAITAUD RESIDENCE ONE HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA ( IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL (FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) F.L./FT (PSI) Pipe: 1 21. 0 1. 025 PL 20.00 PF 3.2 1 0.0 SRCE 47.6 (N/A) 8.2 150 FTG TG PE 0.0 2 0.0 0.0 44.5 0.0 0.105 TL 30.00 PV 0.4 Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 44.5 0.0 13.0 psi, 21. O gpm 2A 0.0 0.0 31. 5 0.0 Pipe: 3 21. 0 1.360 PL 30.00 PF 1.0 2A 0.0 0.0 31.5 0.0 4.6 150 FTG 3L PE 0.0 3A 0.0 H.S. 30.5 5.0 0.027 TL 36.00 PV 0.1 Pipe: 4 16.0 1.265 PL 10.00 PF 0.5 3A 0.0 H.S. 30.5 5.0 4.1 150 FTG TL PE -0.3 3 0.6 0.0 29.8 0.0 0.023 TL 21.00 PV 0.1 Pipe: 5 16.0 1. 049 PL 3.00 PF 0.7 3 0.6 0.0 29.8 0.0 5.9 120 FTG C PE -1. 3 4 3.6 0.0 27.8 0.0 0.086 TL 8.00 PV 0.2 Pipe: 6 16.0 1.109 PL 14.00 PF 1.0 4 3.6 0.0 27.8 0.0 5.3 150 FTG 2E PE -2.6 5 9.6 0.0 24.1 0.0 0.043 TL 24.00 PV 0.2 Pipe: 7 8.0 0.874 PL 102.00 PF 5.5 5 9.6 0.0 24.1 0.0 4.3 150 FTG 7E4TR PE 0.0 6 9.6 0.0 18.7 0.0 0.038 TL 143.00 PV 0.1 Pipe: 8 0.0 0.874 PL 12.00 PF 0.0 6 9.6 0.0 18.7 0.0 0.0 150 FTG T4R PE 0.0 7 9.6 0.0 18.7 0.0 0.000 TL 19.00 PV 0.0 Pipe: 9 0.0 0.874 PL 8.00 PF 0.0 7 9.6 0.0 18.7 0.0 0.0 150 FTG 3ET PE 0.3 7A 9.0 0.0 18.9 0.0 0.000 TL 23.00 PV 0.0 Pipe: 10 0.0 0.874 PL 7.00 PF 0.0 7 9.6 0.0 18.7 0.0 0.0 150 FTG 3E PE 0.3 BA 9.0 0.0 18.9 0.0 0.000 TL 19.00 PV 0.0 Pipe: 11 8.0 0.874 PL 61.00 PF 2.9 6 9.6 0.0 18.7 0.0 4.3 150 FTG E2T5R PE 0.0 9 9.6 0.0 15.8 0.0 0.038 TL 76.00 PV 0.1 Pipe: 12 16.0 0.874 PL 5.00 PF 1.5 9 9.6 0.0 15.8 0.0 8.6 150 FTG 2T PE 0.3 9A 9.0 4.2 14.5 16.0 0 .139 TL 11.00 PV 0.5 Pipe: 13 -8.0 0.874 PL 180.00 PF 8.4 9 9.6 0.0 15.8 0.0 4.3 150 FTG 5E5TR PE 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Date: 07/18/2002 JOB TITLE: GAITAUD RESIDENCE ONE HEAD CALC NOTES: Page 3 C1780SDF.SDF (1) Calculations were performed by the HASS 6.6.0 computer program under license no. 16080621 granted by HRS Systems, Inc. 4792 Lavista Road Tucker, GA 30084 (2) The system has been balanced to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.055 gpm. (3) Velocity pressures are printed for not used in balancing the system. is 8.6 ft/sec at pipe 12. information only, and are Maximum water velocity (4) PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1. 049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B Ell Tee TEERUN COUPLG EL45 0.874 4.00 3.00 1.00 0.00 1.00 1.00 3.00 1.109 5.00 5.00 1.00 0.00 1.00 1.00 3.00 PAGE, I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1.025 3.00 8.00 2.00 2.00 2.00 2.00 0.00 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 PAGE: J MATERIAL: S40PVC HWC, 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A Ell Tee 1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 D 1.00 L 1.00 1.00 D 0.00 0.00 D 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Date: 07/18/2002 JOB TITLE: GAITAUD RESIDENCE ONE HEAD CALC WATER SUPPLY CURVE 72+ O*\ \ \\ I \\\\ \\\\\ 66 +1 \\\\* <-65.0 psi@ 500 gpm Flow Test Point 60+ I 54+ I P 48+X i I S 42+ ~ I 36+ i I I 30+ ) I 24+ I 18+ I============================== 12+ LEGEND 11 I X = Required Water Supply 47.62 psi@ 21.0 gpm 6+ I O = Available Water Supply 69.99 psi@ 21.0 gpm " " " " " " " Page 4 C1780SDF.SDF O++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS UNIVERSAL MODEL A QUICK RESPONSE, 3mm BULB TYPE, 1/2" (15mm) ORIFICE, 1/2" NP,..,. SSU DEFLECTOR* MODEL F700orf7D5 RECESSED ESClfTCHEON rf 112• NPT ** , , ,, PENDENT 1------2-7/8" (73,0mm) DIA. --<..f RECESSED PENDENT 7116• (I 1,1mm) MAKE·IN UPRIGHT CROSS SECTION •Temperature.rating Is Indicated on deflector or adjacent to orifice seat on frame. .. Pipe thread connections par ISO 7/1 can be provided on special request 1 -Frame 2. Button 3 • Gasketed Spring Plate 4 -Bulb 5 -Compression Screw 6 • Oerlector FIGURE A 1/2 INCH ORIFICE MODEL A QUICK RESPONSE PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS GENERAL DESCRIPTION The 1/2 inch (15mm) orifice Universal Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers (Ref. Figure A) are auto- matic sprinklers of the frangible bulb type. They are "quick response • stan- dard orifice spray sprinklers" intended for use in fire sprinkler systems de- signed In accordance with the stan- dard Installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing ls based on NFPA 13 requirements). The Pendent, Recessed Pendent, and Upright Sprinklers all produce a hemispherical water distribution pattem below the de· flector. The recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- nation with either the Model F700 or F705 Recessed Escutcheon (Ref. Rg- uras A and C). The Recessed Escutch- eons have a separable two-piece de- sign which allows installation of the sprinklers and pressure testing of the fire protection system, prior to ceiling construction andlor application of a fin- ish coat to the calling. They also permit Printed In U.S.A. 12·96 refinishing of a ceiling surface without having lo first shut down the fire pro- tection system and remove the sprink- lers. The vertical adjustment provided by the Recessed Escutcoeons substan- tially reduces the accuracy to which the length of fixed pipe drops lo the sprinklers must be cut. Also, the Clo• sure has a 112 inch (12,7mm) wide flange which provides ample clear- ance for covering the mounting hole. APPROVALS AND STANDARDS Laboratory listings end approvals for the 1/2 inch (15mm) orifice Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers are given in Table A. WARNING The 112 inch orifi,tt Mod.el A Quick &spon,;e Pendent, &cessed Pendent, and Upright Sprinklers described herein must b, installed and main- tained in compliance with this docu- ment, as well as applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having juris- diction. Failure to do so may impair the integrity of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should b, contacted rel- ative to any questions. Installation of Model A Pendent Sprinklers in rece6sed escutcheons other than the F700 or F705 will void all sprinkler wcirranties, as well as possibly void the sprinkler's Approv- als and I or Listings. TECHNICAL DATA The 1/2 inch (15mm) orifice Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers are rated for use al a maximum service pressure of 175 psi (12, 1 bar) and they are available in the temperature rat- ings and finishes indicated In Table A. Recessed versions of the Model A Sprinkler are obtained by utilizing the TD515M SELECTION: Sel'OCI the appropriate wrench based on the following requirements: • Model A Sprinklers with a natural brass or chrome plated finish and where the Wrench Flats shown In Agurs A are accas- slble, may be be Install ad using an 8 or 10 Inch adjustable Crescent type wrench or the Model F850 Sprinkler Wrench. • Model A Sprinklers with a polyester coated finish must only be lnstallod with the Model F850 Sprinkler Wrench. Model A Recessed Pendant Sprinklers which are to be Installed after completion of a fixed calHng must only be Installed with Iha Model F850 Sprinkler Wrench. USE: Model F850 Nylon Coated Sprinkler Wrench When using an 8 or 10 Inch adjustable Crescent type wrench the wrench is to be applied to the sprinkler wrench flats only (Ref. Figure A). ' To use the FSSO Sprinkler Wrench, slip Iha Wrench opening over the Model A Sprinkler Deflector by passing the Sprinkler Wrench around the side of the Sprinkler as shown In the above IUustration. Using a 1/2 inch ratchet drive or by applying an 8 or 10 inch adjustable wrench to the hex end of the Sprinkler Wrench, tighten the sprinkler Into the fitting. The two lugs located on opposite sides of the Wrench Indicate the orientation of the sprinkJer frame arms. NOTE Pus.h up on. the Sprinkler Wren.ch, while it is being turned, to ensure: that thi Wrer..ch. recess llay• fully •1160lled with th< ,prin/u,r wrench fiats. Carefully remove tho Sprinkler Wrench by disengaging It from the sprinkler wrench flats, and then passing It sideways over the sprinkler deflector. FIGURED SPRINKLER WRENCH SELECTION AND USE PSN 57 -XXX I X -XXX I TEMPERATURE RATING 135 135"F/57"C SPRINKLER FINISH 155 155"F/68"C TYPE 1 NATURAL BRASS 175 175'F/79'C 371 OR PENDENT 4 WHITE POLYESTER 200 200"F/93'C 370 OR UPRIGHT 9 CHROME PLATED 286 286'F/141'C TABLEB PRODUCT SYMBOL NUMBER SELECTION FOR 1/2 INCH ORIFICE MODEL A QUICK RESPONSE PENDENT AND UPRIGHT SPRINKLERS WITH 1/2 INCH NPT CONNECTIONS been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing ii with a soft bristle brush. Care must be exercised to avoid dam• age to the sprinklers -both before and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from ils bulb (ref. Installation Section Note). NOTES Absence of an escutcheon, which is used to cooer a ckarance lwk, may dekiy the tirM to sprinkler operation in a fire situation. Before closing a fire protectiDn system control oaloe for maintenance work on the fire protection system which it con- trols, permission to shut down the af· fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. ' It is recommended that automatic sprinkler systems be Inspected quar- terly by s qualified Inspection Service. --- WARRANTY Seller warrants for a period of one year from the date of shipment (wenanty period) that the products furnished hereunder will be free from defects In material and workmanship. For further details on Wa1Tanty, see Price List. ----- ORDERING PROCEDURE A Product Symbol Number (PSN) is not specified when ordering polyester coated Model A Sprinklers wllh olher than a while color; when ordering color coated Recessed Escutcheons with other than a white color; or, when or- dering sprinklers with thread connec- tions per ISO 7/1. It is suggested that a color chip be provided when ordering special color finishes. Otherwise, re- sponsibility for duplication cannot be accepted. Contact your local distributor for avail- ability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify tempera- ture rating), Model A Quick Response (specify Pendent or Upright) Sprinkler with (specify type of finish), PSN (specify from Table B). •special Order• Sprinkler Assemblies with ISO 7/1 Thread Connections: Specify: 112• orifice, (specify tempera- ture rating), Mbdel A Quick Response (specify Pendent or Upright) Sprinkler with (specify type of finish) and with thread connection per ISO 7/1. Recessed Escutcheon: Specify: 112• (15mm) Model (specify) Recessed Escutcheon with (specify finish), PSN (specify). 1/2" F700 Chrome ......... PSN 56-701-10 112• F700 While .......... PSN 56·701◄-010 1/2" F705 Chrome ......... PSN 56-705-9-010 1/2' F705 Wille ........... PSN 56•705-4-010 Sprinkler Wrench: Specify: Model F850 Sprinkler Wrench, PSN 56-850-4-001. GD Rao.. -al GRINNELL CORPORATION. 3 TYCO PARK. EXETER, NH 03833 A 'tuca INTERNAOONAL LTD. COMPANY