Loading...
HomeMy WebLinkAbout1903 WRIGHT PL; 300; CB102552; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-09-2011 Commercial/Industrial Permit Permit No: CB102552 Building Inspection Request Line (760) 602-2725 Job Address: 1903 WRIGHT PL CBAD St: 300 Permit Type: Tl Sub Type: INDUST 0 Parcel No: 2120912200 Lot#: Status: Valuation: $60,740.00 Construction Type: 3A Applied: Occupancy Group: Reference #: Entered By: Project Title: COSTANZO FINANCIAL-1635 SF Tl OFFICE TO OFFICE Applicant: WHITE CONSTRUCTION 2540 GATEWAY RD CARLSBAD, CA 92009 760-931-1130 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee STD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $468.48 $0.00 $304.51 $0.00 $0.00 $12.76 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $302.50 Plan Approved: Issued: Inspect Area: Plan Check#: Owner: REALTY ASSOCIATES FUND V LP 1301 DOVE ST #860 NEWPORT BEACH CA 92660 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax ( 4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES ISSUED 12/28/2010 RMA 01/14/2011 01/14/2011 TP Total Fees: $1 ,133.25 Total Payments To Date: $1 ,133.25 Balance Due: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 ?? $1,133.25 $0.00 Inspector: FINAL APPROVAL Date: ~/tf" /; I 5 Clearance: ______ _ NOTICE: Please take NOTICE that approval of your project includes the 'Imposition· of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carl$bad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exrirPd. .. ~ «1~· ~ C I TY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www.carlsbadca.gov SUITEI/SPACEI/UNI JOB ADDRESS 1903 WRIGHT PLACE, CARLSBAD, CA 92008 CT/PROJECT# LOT# PHASE# # OF UNITS # BEDROOMS # BATHR MS Plan Check No. Est. Value 091 22 00 CONSTR. TYPE OCC. GROUP TCT81-46 Lot 8 & 11 Unit 1 Costanzo Financial Group Ill-A B DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) T.I. WILL NOT INCLUDE STRUCTURAL WORK. T.I. WILL INCLUDE NON-LOAD BEARING PARTITIONS ONLY, EXISTING AND RELOCATED SUSPENDED CEILINGS INCLUDING RELOCATED LIGHT FIXTURES. HVAC/ MEC NICAL S JFJS,-/l EXISTING USE PROPOSED USE GARAGE (SF) Vacant B Occupancy B-Occ. Bus.Offica CONTACT NAME (If Different Fom Applicant) ADDRESS ADDRESS ~2S f-r.s CITY STATE ZIP CITY STATE ZIP 0A "21 PHONE FAX EMAIL CITY Ca. TATE cA ZIP q']Olfti'f PHONE f-l 'Clo- FAX PHONE 1vD · EMAIL EMAIL STATE UC.# L\:s 2-S \? CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the prov,srons of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or fhat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}}. WORl<ERS ' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the pertormance of the work for which this permit is issued. ~ have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the pertorma9ce of the WO\k for which thEi ~rm:~d. My workers' compensation i~urancezcamer and policy number are: Insurance eo t> Policy No. C.\/e !( es\ N ~+-,o ~ Expiration Date O 11...P} I 1 I ~section need net be completed ~ the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I cert~y that in the pertormance of the work for which this permit is issued, I sha not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' • co ·s unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as n ection 3706 of the Labor code, interest and attorney's fees. ~ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: □ □ □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is net intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are net intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s} licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. O Yes O No 2. I (have/ have not} signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone I contractors' license number}: 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address/ phone/ type of work): ~ PROPERTY OWNER SIGNATURE □AGENT DATE CO PLETE ,THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business..ll!filJ, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes ~No Is the applicant or future building occupant required to obtain a permit from the air pollution control disttict or a~lity management disttict? [Jves [3 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O Yes l..!:'.INo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and strtethatthe above Information iscolTOCt and that the information on the plans is accurate. I agree to comply ~th all City ordinances and State laws relating to building construction. I hereby authO<ize representative of the City of Car1sba:l to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permtt is required for excavations over 5'CY deep and demolition or oonstruction of structures over 3 stories in height. EXPIRATION: Every permtt issued by the Building Official under the provisions of this Code shall expire by limttation and become null and IIOid ~ the building or work authoozed by such permtt is not commenced within 180 days from the date of such penmtt or if the building orworl\ authorized by such perrrit is sus or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ~ APPLICANT'S SIGNATURE DATE City of Carlsbad Bldg Inspection Request For: 02/11 /2011 Permit# CB102552 Title: COSTANZO FINANCIAL-1635 SF Tl Description: OFFICE TO OFFICE Type:TI Job Address: Suite: Location: Sub Type: INDUST 1903 WRIGHT PL 300 Lot: 0 OWNER REAL TY ASSOCIATES FUND V LP Owner: REALTY ASSOCIATES FUND V LP Remarks: Total Time: CD Description Act Comments 19 Final Structural x_ 29 Final Plumbing t 39 Final Electrical 49 Final Mechanical --- Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# lns12ection Histoey: Date Description Act lnsp Comments Inspector Assignment: TP --- Phone: Inspector..£__ Requested By: NA Entered By: CHRISTINE 02/02/201 1 14 Frame/Steel/Bolting/Welding AP TP T-CLNG PATCH IN TO EXIST & NEW WALLS ELECT/MECH EXISTNG 02/02/201 1 24 Rough/Topout WC TP 02/02/2011 34 Rough Electric WC TP 02/02/2011 44 Rough/Ducts/Dampers WC TP 01 /26/2011 17 Interior Lath/Drywall AP TP 01/20/2011 14 Frame/Steel/Bolting/Welding AP TP 01/20/2011 34 Rough Electric AP TP ~ CltJ DI Carlsbad m Flnal Bulldlng lnspecdon StLiteQ Dept: Building Engineering Planning CMWD Plan Check #: Permit#: Project Name: CB102552 COSTANZO FINANCIAL-1635 SF Tl OFFICE TO OFFICE Address: 1903 WRIGHT PL #300 Contact Person: NA Phone: Sewer Dist: CA Water Dist: CA Inspected Date By: Inspected: Inspected Date By: Inspected : C2 02/11/2011 Permit Type: Tl Sub Type: INDUST Lot: 0 Approved: Disapproved: __ Approved: Disapproved: __ ........................................................................................................................................................... Comments: _______________________________ _ ~ «_~:.~ ,I ~ CITY OF BUILDING Plan Check Comments loo..--CARLSBAD 3"1 Development Services Bulldlng Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov By: Steve Borossay (Contact Hours for Steve: Tuea.-Frt., 1pm -5pm) Phone: 760-602-7541 Permit· C...~ I0'2. :;-i;-z_Addreu· \ 9:03 \/rL~h+:-:: 3?\ Date· \1-['l..E /to I I • When corrections from all departments are received please run new prints • • Please respond by lndlcatln1 location of Plan Check Items on plans • D Provide: A statement on the Title Sheet of the plans stating that the project shaJI comply with the 2007 CA Building Code, 2007 CMC, 2007 CPC, 2007 CEC and the 2008 CA Energy Efficiency Standards. 0 Provide: A note titled "Scope of Wort<' describing the work to be performed under this permit. Tyf'e Of A/~~, V ~~~ ...... ~c..-, ' 12-/:~~jo Cd-f Approved on=--------~~---By: __ 7-:::::r_,c.-::::::""'-------------- ,. .. PLANNING/ENGINEERING APPROVALS PERMIT NUMBER &';3 /I rt7JT2---DATE ;fl,/// ADDREss __ /_9_o 3 _ __;._W,_l'-.;«g+--11/ __ A_t __ _ RESIDENTIAL RESIDENTIAL ADDITION MINOR < < $17,000.00) SOLAR PANELS TENANT IMPROVEMENT PLAZA CAMINO REAL PREMIER OUTLETS VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER _______________ _ PLANNER ______ DATE ______ _ ENGINEER ~,._.____, DATE -~/ /_~_,_!---L../-"--J_ I I off A n-..__ r!J39?-2,-i9t S£ '77 CJ I 7 9 oocs/MlsformS/Plannlng Engineering Approvals «~~ ~ CITY OF CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: jil--Building Permit □ Right-of-Way Permit Patio/Deck Re-Roofing Sign Spa-Factory Sprinkler □ My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria ~My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat' assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tier 1 -Low Threat Assessment Criteria D My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 -Moderate Threat Assessment Criteria D My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 -Significant Threat Assessment Criteria D My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or D My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, D My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I certify to the best of my knowledge that the above checked statements are true and correct. I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. Assessor Parcel No. 'The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be sho'Ml that a lesser or higher Construction SWPPP Tier Level is warranted. B-24 -10 Page 1 of 1 Rev.03/09 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 10-2552 DATE 12/30/10 ADDRESS 1903 Wright Pl RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE OTHER -- POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING PLANNER ~ , Jde~ DATE /~-30-/0 ENGINEER _________ _ DATE ______ _ 11:\ADMIN\COUNTEII/PI.ANNING/ENGINF.ERI 'G Al'PllOVAI.S Recommended for Approval Page: 1 of 3 BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Checked by: Jared Ataiyan Date: January 13, 2011 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Michele Arnold Kush michele@safdierabines.com JURISDICTION: Carlsbad Fire Department PROJECT NAME: Costanzo Financial Group PROJECTADDRESS: 1903 Wright Place .5/e • 5oo PROJECT DESCRIPTION: CB102552 1,635.sf T.I. INSTRUCTIONS ■ This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. ■ The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. ■ To expedite the recheck process, please note on this list (or copy) where each correction item has been addressed, i.e. sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. • PLEASE SEND OR DELIVER REVISED PLANS WITH COMMENTS DIRECTLY TO: Jared Ataiyan 4058 Via De La Paz Oceanside, CA 92057 ■ Please direct any questions regarding this review directly to: Jared Ataiyan 760-721-7660 or ✓Ts.1 Provide List of Applicable Codes (see below) 2007 California Administrative Code (CAC ...................... (Part 1, Title 24, CCR) 2007 California Building Code (CBC), Volumes 1 and 2 ....... (Part 2 Title 24 CCR) (2006 Edition International Building Code with 2007 California Amendments) 2007 California Electrical Code (CEC) ............................ Part 3, Title 24, CCR) (2005 Edition National Electrical Code with 2007 California Amendments) 2007 California Mechanical Code (CMC)...... .. . . . . ... . . . .. . . . . (Part 4, Title 24, CCR) (2006 Edition IAPMO Uniform Mechanical Code with 2007 California Amendments) 2007 California Plumbing Code (CPC) ............................ (Part 5, Title 24, CCR) (2006 Edition IAPMO Uniform Plumbing Code with 2007 California Amendments) 2007 California Energy Code ......................................... (Part 6, Title 24, CCR) (2006 Edition California Energy Commission Building Energy Efficiency Standards) 2007 California Fire Code (CFC) .................................... (Part 9, Title 24, CCR) (2006 Edition International Fire Code with 2007 California Amendments) Page: 2 of 3 Professional Seal Sign professional stamp on all sheets. Required only when structural elements such as bearing walls are demolished and/or constructed. Deferred Submittals List all deferred submittal items. Add the CFC 901.2 for Fire Sprinkler System and CFC 907.1.1 for Fire Alarm Systems. Floor Level Identification Identify floor level. Fire Safety and Prevention Notes Note 5: Revise travel distance to 75'-0" Telephone and Electrical Notes Note 4: Clarify reference to H2A Architects Door and Hardware Notes Note 7: Make corrections to CBC 2007, Section 11011.2 Please verify this code section. Path of Egress Clearly indicate all doors in the path of egress to the public way on the site plan. ✓ EX.3 Revise Break Room occupant load to 15 and revise square footage summary accordingly. Common path of travel is the distance measured from the most remote point (Office 304 and Conference Room 301) to the midpoint in corridor. This distance shall not exceed 75 feet. Revise distance to demonstrate compliance. List exit width requirement and denote actual exit width. Denote occupancy classification of above and below tenant. Denote penetrations of ariy rated assemblies if applicable and provide details and listings for fire and smoke protection. Identify floor level on exit plan. Denote location and mounting height of 2A 1 0BC fire extinguishers on plans with spacing not to exceed 75' max. If applicable, fire extinguisher cabinets in rated walls shall be rated with listings. ✓n.s Denote any penetrations through rated partitions. Add note stating: All doors shall be operable from the egress side without the use of key, special knowledge or effort. Door E-1 : Manually operated flush bolts or surface bolts are not permitted (see CBC 2007, Section 1008.1.8.4). For allowable flush bolts see CBC 2007, Section 1008.1.8.4.3. E-1 : Provide door signage according to CBC 2007, Section 1008.1.8.3.2.2. ✓n.s Provide note on electrical plans to state that installation of back to back outlets shall be staggered 24" min. ✓n.s Denote thermal and acoustical insulation shall comply with CBC 2007, Chapter 7. Provide burning characteristics for all insulation materials specified for this project. ✓r1.9 Provide finish plan note: All interior finishes, decorative materials and furnishings shall comply with the provisions of Title 19 Division 1 Sec. 3.08 and CFC and CBC Chapter 8. Page: 3 of 3 ✓ E2.0 Denote dedicated circuits with Lock-On devices for all fire and safety devices. ✓ E3.0 Denote all emergency lighting shall have minimum 1 foot candle. ✓ M1.0 Mechanical General Notes Note 11: Avoid referencing to generic codes; specify applicable codes such as California Mechanical Code, 2007 Edition. Denote on plans CFM output for existing HVAC. Ducts with cumulative air supply in excess of 2000 CFM shall be equipped with smoke detectors. If applicable, provide note on drawings to state; duct smoke detectors shall interface with fire alarm drawings. If applicable, provide burning characteristics for duct insulation. Add provide California State Fire Marshal Listing which denotes an expiration date of June 30, 2011. CORRECTION LIST Page: 1 of 3 BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Checked by: Jared Ataiyan Date: January 1, 2011 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Michele Arnold Kush michele@safdierabines.com PROJECT NAME: Costanzo Financial Group JURISDICTION: Carlsbad Fire Department PROJECTADDRESS: 1903 Wright Place PROJECT DESCRIPTION: CB102552 1,635.sf T.I. INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. • To expedite the recheck process, please note on this list (or copy) where each correction item has been addressed, i.e. sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. • PLEASE SEND OR DELIVER REVISED PLANS WITH COMMENTS DIRECTLY TO: Jared Ataiyan 4058 Via De La Paz Oceanside, CA 92057 • Please direct any questions regarding this review directly to: Jared Ataiyan 760-721-7660 or TS.1 Provide List of Applicable Codes (see below) 2007 California Administrative Code (CAC ...................... (Part 1, Title 24, CCR) 2007 California Building Code (CBC), Volumes 1 and 2 ....... (Part 2 Title 24 CCR) (2006 Edition International Building Code with 2007 California Amendments) 2007 California Electrical Code (CEC)............................ Part 3, Title 24, CCR) (2005 Edition National Electrical Code with 2007 California Amendments) 2007 California Mechanical Code (CMC)... ... ... . .. . .. . .. .. . .. . (Part 4, Title 24, CCR) (2006 Edition IAPMO Uniform Mechanical Code with 2007 California Amendments) 2007 California Plumbing Code (CPC) ............................ (Part 5, Title 24, CCR) (2006 Edition IAPMO Uniform Plumbing Code with 2007 California Amendments) 2007 California Energy Code ......................................... (Part 6, Title 24, CCR) (2006 Edition California Energy Commission Building Energy Efficiency Standards) 2007 California Fire Code (CFC) .................................... (Part 9, Title 24, CCR) (2006 Edition International Fire C.ode with 2007 California Amendments) Page: 2 of 3 --? TS.1, Continued Professional Seal Sign professional stamp on all sheets. Required only when structural elements such as bearing walls are demolished and/or constructed. Deferred Submittals List all deferred submittal items. Add the CFC 901.2 for Fire Sprinkler System and CFC 907.1.1 for Fire Alarm Systems. • Floor Level Identification Identify floor level. Fire Safety and Prevention Notes Note 5: Revise travel distance to 75'-0" Telephone and Electrical Notes Note 4: Clarify reference to H2A Architects Door and Hardware Notes Note 7: Make corrections to CBC 2007, Section 11011.2 Please verify this code section. Path of Egress Clearly indicate all doors in the path of egress to the public way on the site plan. EX.3 Revise Break Room occupant load to 15 and revise square footage summary accordingly. Common path of travel is the distance measured from the most remote point (Office 304 and Conference Room 301) to the midpoint in corridor. This dista nce shall not exceed 75 feet. Revise distance to demonstrate compliance. List exit width requirement and denote actual exit width. Denote occupancy classification of above and below tenant. Denote penetrations of any rated assemblies if applicable and provide details and listings for fire and smoke protection. Identify floor level on exit plan. Denote location and mounting height of 2A 1 0BC fire extinguishers on plans with spacing not to exceed 75' max. If applicable, fire extinguisher cabinets in rated walls shall be rated with listings. T1.5 Denote any penetrations through rated partitions. Add note stating: All doors shall be operable from the egress side without the use of key, special knowledge or effort. Door E-1: Manually operated flush bolts or surface bolts are not permitted (see CBC 2007, Section 1008.1.8.4). For allowable flush bolts see CBC 2007, Section 1008.1.8.4.3. E-1: Provide door signage according to CBC 2007, Section 1008.1.8.3.2.2. T1 .6 Provide note on electrical plans to state that installation of back to back outlets shall be staggered 24" min. T1 .8 Denote thermal and acoustical insulation shall comply with CBC 2007, Chapter 7. Provide burning characteristics for all insulation materials specified for this project. T1.9 Provide finish plan note: All interior finishes, decorative materials and furnishings shall comply with the provisions of Title 19 Division 1 Sec. 3.08 and CFC and CBC Chapter 8. Page: 3 of 3 E2.0 Denote dedicated circuits with Lock-On devices for all fire and safety devices. E3.0 Denote all emergency lighting shall have minimum 1 foot candle. M1.0 Mechanical General Notes Note 11 : Avoid referencing to generic codes; specify applicable codes such as California Mechanical Code, 2007 Edition. Denote on plans CFM output for existing HVAC. Ducts with cumulative air supply in excess of 2000 CFM shall be equipped with smoke detectors. If applicable, provide note on drawings to state; duct smoke detectors shall interface with fire alarm drawings. If applicable, provide burning characteristics for duct insulation. Add provide California State Fire Marshal Listing which denotes an expiration date of June 30, 2011. SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# ______ _ HV# ________ _ BP DATE._---'--"---- The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 1. Explosive or Blasting Agents 2. Compressed Gases 3. Flammable/Combustible Liquids 4. Flammable Solids 5. Organic Peroxides 6. Oxidizers 7. Pyrophorics 8. Unstable Reactives 9. Water Reactives 1 o. Cryogenics 11. Highly Toxic or Toxic Materials 12. Radioactives 13. Corrosives 14. Other Health Hazards 15. None of These. PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISIONS (HMO): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 31" floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit. /.f FEES ARE REQUIRED. Expected Date of Occupancy: M1! 120 f-0 CalARP Exempt YES NO Date :nitials 1. D flt' Is your business listed on the reverse side of this form? (check all that apply). 2. D ~ Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3. D ~ Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? ii'.! Will your business use an existing or install an underground storage tank? 4. 5. 6. D D D [21' Will your business store or handle Regulated Substances (CalARP)? ~ Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES 1. D 2. D 3. D 4. D Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 0 (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/; or contact the appropriate school district). ~ Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? 121' Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities: fu.ClM~ D~lP Briefly describe proposed project: Name of owner or Authorized Agent Signature of Owner or Authorized Agent FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________________________ _ BY: __________________________ _ DATE: __ _,_/ __ _!/ __ _ EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD APCD COUNTY-HMD APCD COUNTY-HMD APCD HM-9 171 (04/07) County of San Diego -DEH -Hazardous Materials Division