HomeMy WebLinkAbout1902 WRIGHT PL; 180; CB110748; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
05-06-2011 Commercial/Industrial Permit Permit No: CB110748
Building Inspection Request Line (760) 602-2725
Job Address: 1902 WRIGHT PL CBAD St: 180
Permit Type: Tl Sub Type: INDUST
0 Parcel No: 2120912600 Lot#: Status:
Valuation: $278,326.00 Construction Type: 3A Applied:
Occupancy Group: Reference #: Entered By:
Project Title: TRANSPORTATION MANAGEMENT
7498 SF OFFICE TO OFFICE
Applicant:
WHITE CONSTRUCTION
2540 GATEWAY RD
CARLSBAD, CA 92009
760-931-1130
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Fire Expedited Plan Review
$1 ,297.49
$0.00
$843.37
$0.00
$0.00
$58.45
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$8.00
$317.50
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
REAL TY ASSOCIATES FUND V LP
1301 DOVE ST #860
NEWPORT BEACH CA 92660
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
T raffle Impact Fee ( 4305541 )
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
TOTAL PERMIT FEES
ISSUED
04/11/201 1
RMA
05/06/2011
05/06/2011
Total Fees: $2,609.81 Total Payments To Date: $2,609.81 Balance Due:
VAL
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$41 .00
$20.00
$24.00
$0.00
$0.00
$0.00
$0.00
??
$2 ,609.81
$0.00
Inspector: Date: _.s,4-!..JI..L,..L...,!.I __ Clearance: ______ _
NOTICE: Please take NOTICE that approval cf your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review. set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions f which ou have revious been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
~ «•::~ ~ C I TY OF
CARLSBAD
JOB ADDRESS L
CT/PROJECT #
CITY
PHONE
EMAIL
EMAIL
ARCH/DESIGNER NAME & AOORESS
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718/ 2719
Fax: 760-602-8558
www .ca rlsba dca .gov
# BEDROOMS
PROPOSED USE GARAGE (SF) -n -o f-t'·
vtA-Date
STATE ZIP so
FAX
92olt
3
p~CPO 'l3/ -lt 30
EMAIL
STATE LIC. # STATE LI.# sz <5 l 3
STATE CA
FAX
FAX
CLASS
CONSTR. TYPE OCC. GROUP g
FIRE SPRINKLERS
YES;(' NO □
c ,
}00
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct. alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Cha'fter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 703 .5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-insure for wor1<ers' compensation as provided by Section 3700 of the Labor Code, tor the performance ot the wor1< f0< which this permit is issued. ,tJ.-' have and will maintain worker.;" compensation, as required by Section 37 of the Labor ode ~e performance of the work for which this permit is issue My wor1<ers' CO<npensation insurance carrier and policy
number are: Insurance Co. l V c'pohcy No. _...i..:,µu.,.~<-1...A."\cGl-'-"-"-l-£""'--Expiration Date _________ _
This section need not be CO<npleted if the permit is for one hundred dollars ($100) or less. c~ vi)f). N D Certificate of Exemption: I certify that in the performance of the wor1< fOf which this permit is issued, I shall not employ any person in any manner so as to beCO<ne subject to the Wor1<ers' Compensation Laws of
Calif0<nia. WARNING: Failure to secure workers' compensation coverage is unlawfu all subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as rovided for in S • e Labor code,· terest and attorney's fees.
I hereby affirm that I am exempt from Contract0<'s Ucense Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the wor1< and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds °' improves thereon, and who does such wOfk himself or through his own employees, provided that such improvements are not intended Of offered f0<
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder wiU have the burden of proving that he did not build Of improve for the purpose of sate).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds Of improves thereon, and contracts for such projects with contract0<(s) licensed pursuant lo the Contractor's License Law).
D I am exempt under Section _____ B,usiness and Professions Code for this reason:
1. I personalty plan to provide the maj0< labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have / have not) signed an application f0< a building permit f0< the proposed wor1<.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractOfS' license number):
4. I plan lo provide portions of the WOfk, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone I contract0<s' iicense number):
5. I will provide SO<ne of the wor1<, but I have contracted (hired) the following persons to provide the wor1< indicated (include name / address / phone I type of wor1<):
,J!S PROPERTY OWNER SIGNATURE □AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Address
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinan""5 and State laws relating to building construction,
I hereby authorize representative of \he City of Carlsbad 10 enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations (Ner 5'0' deep and demolition Of construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by Imitation and becorre null and void ~ \he building Of wori< authorized by such permt is not commenced within
180 days from \he date of such permt or if the buiding Of WOO< auth • rmil is suspended or abandoned at any time after the worl< is commenced fOf a period of 180 days (Section 106.4.4 Uniform Building Code).
_€5 APPLICANT'S SIGNATURE DATE 4 -{ -( Ii
~ Chi 11 Clrllllllll m nnal Bulldlna lnspacdan
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check #: Date: 06/02/2011
Permit#: CB110748 Permit Type: Tl
Project Name: TRANSPORTATION MANAGEMENT Sub Type: INDUST
7498 SF OFFICE TO OFFICE
Address: 1902 WRIGHT PL #180 Lot: 0
Contact Person: NA Phone:
Sewer Dist: CA Water Dist: CA -~:~~~;~;~--~-----~£~:=:··~r;;J··i~-~;~-;~~~~--~~~~:~:~~:·=·
a ._..,,
Inspected Date
By: ___________ Inspected: _____ Approved: ___ Disapproved:
Inspected Date
By: ___________ Inspected: _____ Approved: ___ Disapproved: __
Comments: ______________________________ _
@) .
. City of Carlsbad Bldg Inspection Request
. For: 06/06/2011 .
Permit# CB110748
Title: TRANSPORTATION MANAGEMENT
Description: 7498 SF OFFICE TO OFFICE
Type: Tl Sub Type: IN DUST
Job Address: 1902 WRIGHT PL
Suite: 180 Lot: 0
Location:
OWNER REAL TY ASSOCIATES FUND V L P
Owner: REAL TY ASSOCIATES FUND V L P
Remarks:
Total Time:
CD Description Act Comments
Inspector Assignment: TP ---
Phone:
Inspector: _f!__
Requested By: NA
Entered By: JANEAN
19 Final Structural _£_ __________ _
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
lnsQection History
Date Description Act lnsp Comments
06/02/2011 89 Final Combo co TP
06/02/2011 152 Final Bldg Inspection -Fire AP cw
05/23/2011 14 Frame/Steel/Bolting/Welding AP TP T-CLNG GRID PATCH IN TO EXIST.
05/23/2011 24 Rough/Topout WC TP
05/23/2011 34 Rough Electric AP TP NEW CLNG LITES.
05/23/2011 44 Rough/Ducts/Dampers WC TP NO NEW WORK
05/13/2011 17 Interior Lath/Drywall AP PD
05/09/2011 14 Frame/Steel/Bolting/Welding AP TP
05/09/2011 24 Rough/Topout WC TP
05/09/2011 31 Underground/Conduit-Wiring AP TP
05/09/2011 34 Rough Electric AP TP
05/09/2011 44 Rough/Ducts/Dampers WC TP
DATE: 5/5/ 11
JURISDICTION: Carlsbad
PLAN CHECK NO.: 110748
EsGil Corporation
In <Partnersliip witli (jovernment for <Bui{aing Safety
SET: III
PROJECT ADDRESS: 1902 Wright Pl, Suite #180
□~NT
□(JURIS. ')
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Transportation Management & Design Office TI
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
Safdie Rabines Interior, Att'n: Michele Arnold-Kush
925 Ft. Stockton Dr, San Diego, CA 92103
~ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Michele Arnold-Kush Telephone#: (619) 297-6153
Date contacted: (by: ) Email: michele@safdierabines.com Fax #:
Mail Telephone Fax In Pe rson
~ REMARKS: The loose sheets (Tl.5 and Tl.8) must be slip-sheeted into the sets already at the
City.
By: Chuck Mendenhall
EsGil Corporation
□ GA □ EJ □ PC
Enclosures:
log
9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fornia 92 123 ♦ (858) 560-1 468 ♦ Fax (858) 560-1 576
DATE: 4/29/11
JURISDICTION: Carlsbad
PLAN CHECK NO.: 110748
EsGil Corporation
In (!'artnersliip witli (Jovernment for <Bui{aing Safety
SET: II
PROJECT ADDRESS: 1902 Wright Pl, Suite # 180
~~T ~
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Transportation Management & Design Office TI
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Safdie Rabines Interior, Att'n: Michele Arnold-Kush
925 Ft. Stockton Dr, San Diego, CA 92103
D Esgil Corporation staff did not advise the applicant that the plan check has been completed .
~ Esgil Corporation staff did advise the applicant that the plan check has been completed .
Person contacted : Michele Arnold-Kush (" • 1--1) Telephone #: (619) 297-6153
Date contacted: 5'~ L \ 1 1 (by: ~ ) Email: michele@safdierabines.com Fax #:
t Mail ./ Telephone/ Fax In Person
0 REMARKS:
By: Chuck Mendenhall
EsGil Corporation
□ GA □ EJ □ PC
Enclosures:
4/26/11
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
NOTE: The items listed below are from the previous correction list. These remaining items
have not been adequately addressed. The numbers of the items are from the previous check
list and may not necessarily be in sequence. The notes in bold font are current.
Please make all corrections, as requested in the correction list. Submit FOUR new complete
sets of plans for commercial/industrial projects (THREE sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will
route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining
sets of plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete.
1. Incidental use areas may need to be separated from the main occupancy. See Table 508.2.5
below. Please address the following specific concerns:
Even if sprinklers are used to eliminate the need for 1-hour wall construction, Section
508.2.5.2 still requires the partitions to extend to the underside of the floor/roof above and for
any doors in the partitions to be self-closing. This applies to storage room 101. NOTE: The
walls of room 101 between 101 and adjacent reception Rm 110 must be full height
extending to the roof or floor above and sealed to prevent spread of smoke. The door
into the Storage 101 must be self closing with smoke seals.
END OF RECHECK
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed , i.e., plan sheet, note or detail number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review items,
please contact Chuck Mendenhall at Esgil Corporation. Thank you.
EsGil Corporation
In <Partnersliip witli (Jovernment for <Buifaing Safety
DATE: 4/19/11
JURISDICTION: Carlsbad
PLAN CHECK NO.: 110748 SET: I
□ FILE
ANT
.
REVIEWER
PROJECT ADDRESS: 1902 Wright Pl, Suite #180
PROJECT NAME: Transportation Management & Design Office TI
□
□
□
□
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person .
The applicant's copy of the check list has been sent to:
Safdie Rabines Interior, Att'n: Michele Arnold-Kush
925 Ft. Stockton Dr, San Diego, CA 92103
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: J:lich/le ArlJ?11d-Kush Telephone #: (619) 297-6153
Date contacted:1 ( l'f / I 1(bJ~ Email: michele@safdierabines.com Fax #:
~ail✓'relephom.
REMARKS:
By: Chuck Mendenhall
EsGil Corporation
0 GA O EJ O PC
Enclosures:
4/12/11
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 110748
OCCUPANCY: B
TYPE OF CONSTRUCTION: III A
ALLOWABLE FLOOR AREA: no change
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 4/19/11
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Office
ACTUAL AREA: 7 498 TI Only
STORIES: 3
HEIGHT: n o change
OCCUPANT LOAD: 108
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/12/11
PLAN REVIEWER: Chuck Mendenhall
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC.
The following items listed need clarification , modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2009 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Please make all corrections, as requested in the correction list. Submit FOUR new complete
sets of plans for commercial/industrial projects (THREE sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will
route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining
sets of plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete.
1. Incidental use areas may need to be separated from the main occupancy. See Table 508.2.5
below. Please address the following specific concerns:
a) Even if sprinklers are used to eliminate the need for 1-hour wall construction, Section
508.2.5.2 still requires the partitions to extend to the underside of the floor/roof above
and for any doors in the partitions to be self-closing. This applies to storage room
101
Storage rooms over 100 square 1 hour or provide automatic fire-extinguishing
fu~ s~em
2 . Note onsheet Tl.5 of the plans: "All egress doors shall be readily openable from the egress
side without the use of a key or special knowledge or effort." Section 1008.1.9.3. In lieu of the
above, in a Group B, F, Mor S occupancies (or Group A having an occupant load of 300 or
less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR
TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." This signage is only allowed at
the main exit.
• ENERGY CONSERVATION
3. Occupancy sensors are required for the following room types: Offices 250 square feet and
smaller, multipurpose rooms less than 1,000 square feet, and classrooms and conference
rooms of any size. Please add where appropriate. Section 131 . Mot5in sensor ( occupancy
sensor) light switch is required in Conf. Room 103. •
END OF REVIEW
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review items,
please contact Chuck Mendenhall at Esgil Corporation. Thank you.
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Chuck Mendenhall
PLAN CHECK NO.: 110748
DATE: 4/19/11
BUILDING ADDRESS: 1902 Wright Pl, Suite #180
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: III A
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplie r
Office Tl 7498 City Est
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance I ""' I
Plan Check Fee by Ordinance I• I
Type of Review: 0 Complete Review
D Reprtive Fee -1,.. Repeats
----'
Comments:
D Other
0 Hourly
EsGil Fee
Reg . VALUE
Mod.
D Structural Only
($)
278,326
278,326
$1 ,297.491
$843.371
$726.591
Sheet 1 of 1
macvalue.doc +
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER _C_'B_l _l -_7_4_CZ __ _ Mr it /,, DATE_....;.4 ...... --.-----t
ADDRESS \O") O 2--'N Rl&H\ PL-A C€ I STC
I
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
(<$17,000.00)
C TENANTIMPROVE~
<.
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER __________ DATE ________ _
ENGIN~ DATE____,;~ ... 0 _/1/_,,__/ _{-_
. Q:IFOEng\OaweloplMnl ~Viar plada:lcit,Q\IIUN.DING PI.NtCHECK CKLIST FORM. PlANNING ENGINERING
APPROV ALS.docx '-' •
I ' '
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 11-0748 DATE4/11/11
ADDRESS 1902 Wright Place #180
RESIDENTIAL ADDITION-.
MINOR (<17,000.00)
RETAINING WALL
VILLAGE FAIRE
OTHER --
POOL/SPA
E NTIMP ~OVEMENT ---__.-// ··---
COMPLETE OFFICE BUILDING
PLANNER ~~rl"\ DATE J../-//-/ /
ENGINEER. ________ _ DATE ______ _
11:\ADlllN\aJUNTER/l'LANNING/F.NGINF.ERING APPROVALS
.
I
I
I m . Carlsbad Fire Department 1
Plan Review Requirements Category: TI , INDUST
Date of Report: 05-03-2011
Name:
I WHITE CONSTRUCTION
Address: 2540 GATEWAY RD 1
CARLSBAD, CA
92009
Permit#: CBl 10748
Job Name: TRANSPORTATION MANAGEMENT
Job Address: 1902 WRIGHT PL CBAD St: 180
~ UiLDl~G DEPT ..
-or.· .... , • .. • i. •
Reviewed by: _I/...,,__. ~-1----
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxjxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
XX~ftlPM'J~XX~~~Ai~~~~~ ~,:~~)i~JiH~tt)t¥~X~'i!J.lC~~~~UW.M~l'XXXXXXX ::!~■-!---!!!tlli!milEi XXMX~m~~xxxxxxxxx1xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Conditions:
Cond: CON0004593
[MET]
** CITY OF CARLSBAD FIRE DEPARTMENT-APPROVED: W/NOTES.
THIS PROJECT HAS BEEN REVIEWED AND 1APPROVED FOR THE PURPOSES OF ISSUANCE OF
BUILDING PERMIT. I
I
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON,
CONDITIONS IN ku
CORRESPONDENCE AND CONFORMANCE I .. ITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
1. ACCESS TO LIFE SAFETY SYSTEM REQUIRED -OCCUPANT MUST PROV1DE KEY ACCESS TO SUITE
AND OFFICE
104. I
Entry: 05/03/2011 By: GR Action: AP '