HomeMy WebLinkAbout1900 WRIGHT PL; 100; CB020938; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
• 04-24-2002 Commercial/Industrial Permit Permit No: CB020938
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Tille:
1900 WRIGHT PL CBAD St: 100
Tl Sub Type:
2120912500 Lot#:
$129,060.00 Construction Type:
Reference #:
HEDGEWORKS -Tl 4302 SF
SHELL TO OFFICE
COMM
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
ISSUED
03/28/2002
JM
04/24/2002
04/24/2002
Applicant:
Inspect Area:
Owner: 5830 04/24/02 0002 01
REALTY ASSOCIATES FUND V LP CGP HORN PENNE
4141 JUTLAND DRIVE
SAN DIEGO CA 92117
858-739-9090
Total Fees: $3,575.27
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
STD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Inspector: _ ___.6'-----'0;;;;;...._
C/O LEGACY PARTNERS
101 LINCOLN CENTRE DR
FOSTER CITY CA 94404
Total Payments To Date: $415.32 Balance Due:
$638.96
$0.00
$415.32
$0.00
$0.00
$27.10
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF
PFF (CFO Fund)
License Tax
License Tax (CFO Fund)
Traffic Impact Fee
Traffic Impact (CFO Fund)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOT AL PERMIT FEES
$3,159.95
$0.00
$0.00
$0.00
$0.00
$2,348.89
$0.00
$0.00
$0.00
$0.00
$0.00
$34.00
$60.00
$51.00
$0.00
$0.00
$0.00
$0.00
$3,575.27
FINAL AP,PROVAL
Date: b.--I/' t? ,,a._ Clearance: _____ _
NOTICE: Please take NOTICE that approval of your project includes the "Imposition· of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.• You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any . . . Tl . . • I • •
02
3159-95
FOR OFFICE USE ONLY
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008 Validated B ,,._J-,;.. _ _,_ __ .,....,__,....,,.._~
Date ________ __.4--=::c.....::;µ.. __ _
1. PROJECT INFORMATION
al # of uni s. > "3 )
\ttv\ P-e-t}✓ ~~T. 4-~2. #of Stories 8
licant)
State/Zip Telephone# Fax#
0
SD cA-Cf
City State/Zip
5. CO TRACTOR • COMPANY NAME
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exam tion. Any violation of Section 7031.5 by any applicant for a permit subjects the a plicant to a civil penalty of not more than five hundred dollars ($5001). 1u :TB cot-JS,"'\", B-'l , 0, zo ~ //30
State license # _________ _
6. WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
D"J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
,rs;;:;ed. My worker's compensation insurance carrier and policy number are: ~ I,,. L /
Insurance Company '?'"TA-Tc;, P\A. tJD Policy No. ~!CJ-02 Expiration Date I_/ /03 • (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to cure workers' ation coverage is unlawful, and shall subject an employer to crimin • nd civil fines up to one hundred
thousand dollars ($10 0 st of compensation, damages as provided for in Section 3706 of the I0nt~and attorney·s fees.
SIGNATURE ___ ~S:::,!~~~=.....!.S:::i~!.!::~=---------------DATE __ ..._,...,..._..,__=----
7. OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors license number): _________________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work): ____________________________________________________________ _
PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 D YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
8. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME ______________ _ LENDER'S ADDRESS ________________________ _
9. APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit i n menced within 180 da from the date of such permit or 11 the building or work authorized by su~h permit 1s suspended or abandoned
at any time after the work is ced or a period of 1 0 s (S ct1on 106.4 4 Uniform Building Code) DATE 3 ,~d 'A?
APPLICANT'S SIGNATURE -~·-~ I
YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 06/10/2002
Permit# CB020938
Title: HEDGEWORKS -Tl 4302 SF
Description: SHELL TO OFFICE
Type:TI
Job Address:
Suite:
Location:
Sub Type: COMM
1900 WRIGHT PL
100 Lot 0
APPLICANT HORN PENNE
Owner: REAL TY ASSOCIATES FUND V LP
Remarks:
Total Time:
Inspector Assignment: TP ---
Phone: 7604973114
Inspector: !:Ls
Requested By: BOB
Entered By: CHRISTINE
CD Description Act Comments
19 Final Structural f1 ,-0
29 Final Plumbing t 39 Final Electrical
49 Final Mechanical
Associated PCRs
lnsgection Histor:t
Date Description Act lnsp Comments
06/06/2002 89 Final Combo co TP NEED ACCESS TO SUB PNLS
05/29/2002 39 Final Electrical PA TP MTR REL
05/23/2002 14 Frame/Steel/Bolting/Welding AP TP T-BAR CEIL
05/23/2002 24 Rough/Topout WC TP
05/23/2002 34 Rough Electric AP TP CEIL LITES
05/23/2002 34 Rough Electric AP TP SUB PNLS, TRANS
05/23/2002 44 Rough/Ducts/Dampers AP TP DUCTS, HP S
05/22/2002 84 Rough Combo NS TP
05/15/2002 17 Interior Lath/Drywall AP TP
05/08/2002 14 Frame/Steel/Bolting/Welding AP TP WALLS
05/08/2002 34 Rough Electric AP TP
04/30/2002 22 Sewer/Water Service WC TP
04/30/2002 24 Rough/Topout AP TP
..
Citv of Carlsbad
~ -~ Final Building Inspection .~-
Dept: Building Engineering Planning CMWD St L~
Plan Check#:
Permit #:
Project Name:
Address:
CB020938
HEDGEWORKS -Tl 4302 SF
SHELL TO OFFICE
1900 WRIGHT PL #100
Contact Person: JASON Phone: 7604978411
Water Dist: CA Sewer Dist: CA
~;:pected {!_ (;Jufd__ Date t-;ff:>-Inspected:
Inspected Date
By: Inspected:
Inspected Date
By: Inspected:
Comments:
Date: 06/06/2002
Permit Type: Tl
Sub Type: COMM
Lot: 0
Approved: ~approved:
Approved: Disapproved: __
Approved: Disapproved : __
--------------------------------
r--,
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 4/11/02
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 02-938 SET: I
PROJECT ADDRESS: 1900 Wright Place Suite 100
PROJECT NAME: Hedgeworks -TI
~
CANT
JUR
0 AN REVIEWER
0 FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: Fax#:
Mail Telephone Fax In Person
~ REMARKS: The person responsible for the plans to make changes marked in red to the city
held sets.
By: Doug Moody
Esgil Corporation
0 GA O MB O EJ O PC
Enclosures:
4/1/01 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
....
City of Carlsbad 02-938
4/11/02
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Doug Moody
PLAN CHECK NO.: 02-938
DATE: 4/11/02
BUILDING ADDRESS: 1900 Wright Place Suite 100
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN
BUILDING AREA Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod.
Tl 4302 City Valuation
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1994 UBC Building Permit Fee j -..1
1994 UBC Plan Check Fee , ,.. ,
Type of Review: Complete Review D Structural Only
0 Repetitive Fee ~ Repeats
Comments:
D Other
D Hourly ._ ___ ___,I Hour*
Esgil Plan Review Fee
($)
129,060
129,060
$638.961
$415.321
$357.821
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS , /Cf tlJ
RESIDENTIAL ••
RESIDENTIAL ADDITION MINOR
( < $10,000.00)
·oTHER
r:=IMPRO-~
· PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLACE' FAIRE
COMPLETE OFFICE BUILDING
--------------------
OOCS/MISformslPfanning Engineering Approvars
Carlsbad Fire Department 020938
1635 Faraday Ave.
Carlsbad, CA 92008 Fire Prevention
(760) 602-4660
Plan Review Requirements Category: Building Plan
Reviewed by: Date of Report: _0_41_22_1_20_0_2 _______ _
Name: Inter Arch
Address: 4141 Juliand Dr #320
City, State: San Diego CA 92121
Plan Checker: Job #: 020938 -------
Job Name: Hedgeworks #100 Bldg #: CB020938 ------------------"~
Job Address: 1900 Wright Place Ste. or Bldg. No. 100 ------------------------
[8J Approved
D Approved
Subject to
D Incomplete
Review
FD Job#
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and/ or specifications to this
office for review and approval.
1st
020938
2nd
FD File#
3rd Other Agency ID
Carlsoad Fire Department 020938 -,
1635 Faraday Ave.
Carlsbad, CA 92008
Fire Prevention
(760) 602-4660
Plan Review Requirements Category: Building Plan
Reviewed by: Date of Report: _o_41_18_t_20_0_2 _______ _
Name: Inter Arch
Address: 4141 Juliand Dr #320
Cit,r, State: San Diego CA 92121
Plan Checker: Job #: 020938
Job Name: Hedgeworks #100 Bldg #: CB020938 ________________ ___,:c.__
Job Address: 1900 Wright Place Ste. or Bldg. No. 100 ------------------------
LJ Approved
LJ Approved
Subject to
[ZI Incomplete
Review
FD Job#
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and/ or specifications to this
office for review and approval.
1st
020938
2nd
FD File#
3rd Other Agency ID
"
City of Carlsbad
li•i4i•J4·EIIU,14111
Office of Fire Protection Services
POLICY
October 25, 2000
SMOKE FIRE DAMPERS
Background -The 1997 California Building Code Section 713.10 has revised the
actuation requirements for smoke dampers. Generally, smoke dampers are required to be
actuated by either a smoke detector or a total-coverage smoke-detection system. Deputy
Fire Marshals, Plan Checkers and Field Inspectors have found that stand-alone smoke
detectors used to actuate these dampers are not listed with the California State Fire
Marshal for that purpose. This complicates and extends the plan review process and
causes delays in final inspection in the field. Therefore, until industry lists stand-alone
smoke detectors for use in actuating smoke-fire dampers, the following policy will be
· used in the City of Carlsbad:
Policy -Smoke fire dampers are required to be wired to an approved fire alarm system.
Building plan submittals are required to note that the smoke fire dampers and smoke
detectors that actuate the dampers comply with the above provision. A separate submittal
to the Fire Department from a licensed fire alarm contractor is required for plan review of
these systems. The submittal shall include floor plans, mechanical details of the dampers,
wiring diagrams, permit fees, State Fire Marshal listings and manufacturer's cut sheets on
all devices.
This policy may be reconsidered and modified when the smoke detector manufacturers
have listed these devices with the California State Fire Marshal for this specific purpose.
Building permits including such stand-alone systems will not be issued until it can be
demonstrated prior to permit issuance that all components of such systems are listed for
their intended purpose by the California State Fire Marshal's Office.
Fire Marshal Approval Date
1635 Faraday Avenue• Carlsbad , CA 92008 • (760) 602-4660 • FAX (760) 602-8561