Loading...
HomeMy WebLinkAbout7988 PASEO ESMERADO; ; AS010080; Permit10/31/25, 2:19 PM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: about:blank Fees($) 190 ASO 10080 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS010080 7988 PASEO Status: PENDING ESMERADO SPRINK Applied 4/5/2001 2645500300 Approved: 0 Issued: Inspector: THORELL RESIDENCE Add'I Fees ($) 0 Owner: THORELLLENNYJ&ANDREAS 7988 PASEO ESMERADO CARLSBAD CA Total($} 190 Balance($) 0 1/1 Carlsbad Fire Department 982730 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report _04_1_10_12_0_0_1 _______ _ Auto. Sprinkler, OH Reviewed by: Name: RL T Fire Protection Address: P.O. Box 2209 City, State: Lakeside CA 92008 Plan Checker: Job#: Job Name: Thorell Residence Bldg#: CB982730 --------------------==--- Job Address: 7988 Paseo Esmerado Ste. or Bldg. No. IZI Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and I or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 982730 2nd FD File# 3rd Other Agency ID Caution Model F1 /RES ·CCP Concealed Residential Sprinkler Read Carefully! Installation Instructions -General 1. ~Joo..~~~~~Mg.,Q,O~~~~~l!¥ I • 1 dent pnnkler. Igure Is typical. 2. ~08fe~?r¥fte6W~kf;:®blywith Model F1FR. 3. Use only the 135°F (57°C) temperature rated Model CCP cover plate assembly with the Model F1/RES 18 Pendent sprinkler. Refer to Buftetin 141 and this caution sheet for tech- nical information. 4. Use the appropriate temperature· rated Model CCP cover plate assembly with either the Model F 1 FR or F 1 FR OREC Pendent sprinkler in accordance with Bulletin 143 or 151 and Caution Sheet CA-70. 5. Install sprinklers after ceiling Is in place. 6. Never apply paint and/or other coating spnnkler or concealed sprinkler cover plate. 7. Do not install concealed sprinkler in ceilings, which have posi- tive pressure in the space above. and do not cover the cup vent holes. An open plenum space must be above the sprin- kler cup. 8. Use a Model C 1 Wrench (Fig. 1) to install sprinklers. Face of ~nk!er fitting to ceiling dimension is shown on Fig. 3 or Fig. 4. Ceiling hole diameter Is 2¼" {67mm). 9. Final adjustment of each cover can be made by hand tuming the cover plate in the clockwise direction until it Is tight against the ceiling. 10. Never install the Model F1/RES CCP Concealed Residential Sprinkler in areas where ceiling temperatures exceed 100 °F {38°C). 11. When residential sprinklers are installed in plastic piping sys- tems containing glycerin, special care is required to achieve a proper thread seal. Installation Wrench Model RC 1 Sprinkler Wrench Fig.2 Description The Model F1/RES CCP Concealed Residential Sprinkler is a UL listed residential sprinkler intended to be installed in the wet pipe sprinkler_ systems ot one and tow family dwellings and mobile homes. in resIdentIal occupancies up to tour stones in height or the residential portions of any occupancy per NFPA 130, 13R or 13. The Deflector of the Model F1/RES 18 is marked "Pend.", "Res. Sprkr". "F1/RES 18," "155 °P' and "K=3.9." The frame wrench boss is marked "RASCO" and "F1 3.9.~ The riush-on cover plate assembly is labeled "RASCO," 135 °F (57 °C) Mode! CCP cover plate --for use with Reliable Model f:1/RES 18. 3.9 K orifice, 155 °F (68°C) sprinkler only." Installation Apply a Teflon'"1-based thread sealant to the sprinkler threads only. The Model RC 1 Wrench is then used to engage the sprinklr,;r wrenching surfaces to install the sprinkler in 1he fitting. A 2Ya" (67mm) diameter hole cut into the ceiling allows the sprinkler to be properly covered by the push on cover plate. Push the over plate assembly by hand into the cup. Final adjustment, if required. is made turning the cover plate clockwise until the cover late flange is in contact with ceiling surface. Th M 1 1 r· kl r is in II •:V1th 1 °F 7° n- I V r la P. m Ii . Use care to avoid damaging the sprinkler before. during and after installation. Replace all sprinklers, which have any sign of dam- age. Tne temQ_erature rating of residential sprinklers is stamped on d~ fleeter. The sprinkler or1!1ce size 1s determined by the "K Factor which 1s marked on the spnnkler. Technical Data Fig 1 Reliable authorized plated and painted Model F1/RES Sprinklers _:_::_c=-c.______c__:_:__ ___________________ are distinguished by the ,Jronze pipe cap inset. v-Jhen ambient "Thread Maximum Ternp,rature Rating ~/.;1:,num temperatures are in doubt. measure with an accurate thermom~ Size Pressure Sprinkler Cover Ambient Temp .. ter. Refer to NFPA 13, 130, 13R and Reliable product Bulletin 141 for ·:/' (RY,) 17Spsig(12barl 1ss°F(68°C) I3S°F(57"C) • 100'ff3B'Cl further installation details and for specific approval information. Installation Data NFPA 13, 13D and 13R Maximum Minimum Required Sprinkler Dlseharga Nominal "K"Factor Sprinkler Spacing DIStanceTo Single Sprinkler Two Or More Sprinklefs Model Orfflce Wall Size Flow Pressure FlowEa. Pnl9ure Ea. us Metric : ft. X ft. mxm tt. m .,. gpm Umin psi bar gpm Umin; psi bar 12x 12 3.7x3.7 6 18 1J 41.6 8.0 0.6 10.5 39.7 7.2 0.5 Fl/RES 14 X 14 43 X 4.3 7 2.1 12 45.4 9.5 0.7 10.5 39.7 7.2 0,5 39 55.B 16x 16 49x49 3 2.4 15 568 148 1.0 12 454 95 0.7 Concea,ea· r1ommI 18x 18 5.5 X 5.5 g 27 16 60.6 168 1.2 13 49.2 11.1 0,8 20x20 60x60 i(; ::i'J 18 68.1 21.3 1,5 14 53.0 12.9 0.9 The Reliable Automatic Sprinkler Co., Inc., 525 North MacOuesten Parkway, Mount Vernon. New York 10552 CA-60C Reliabl~ The Lifesaver Line of Residential Glass Bulb Sprinklers 1. Model F1/RES 16 Pendent (8.0 gpm/7.1 psi)11l 2. Model F1/RES 18 Pendent (10.5 gpm/6.2 psif 1 3. Model F1 /RES 20 Pendent ( 14.0 gpm/11.1 psif 1 4. Model F1/RES Pendent 5. Model F1/RES 2 Pendent 6. Model F1/RES 16/F1 or F2 Recessed Pendent 7. Model F1/RES 18/F2 Recessed Pendent 8. Model F 1 /RES 20/F 1 or F2 Recessed Pendent 9. Model F1/RES/F2 Recessed Pendent 10. Model F1/RES 2/F2 Recessed Pendent 11. Model F1/RES/3 Horizontal Sidewall 12. Model F1/RES Horizontal Sidewall 13. Model F1/RES/3/F2 Recessed Horizontal Sidewall 14. Model F1/RES/F2 Recessed Horizontal Sidewall i1lMinimum two sprinkler flow requirement Refer to Installation Data Table. Product Description All Model F1 Residential Sprinklers are fast response residential glass bulb automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model F1 Residential Sprinklers utilize a 3.0mm frangi- ble glass bulb_ These sprinklers have demonstrated re- sponse times in laboratory tests which are five to ten times faster than standard sprinklers of the same tem- perature rating. • The Models F1 Pendent and Recessed Pendent Resi- dential Sprinklers discharge water in a hemispherical pattern below the sprinkler deflector Models F1 Horizon- tal Sidewall and Recessed Horizontal Sidewall Resider.- tial Sprinklers discharge water in a quarter spherical pattern which distributes approximately 10% ot the water on the backwall and 90% on the three remaining walls and floor. These residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high dis- charge pattern has demonstrated. in fire testing. an abil- ity tor controlling residential fires thereby providing significant evacuation time for occupants. The Model F 1 Residential Sprinklers may be installed in the resrdential portions of any occupancy in accordance with NFPA 13. 130 or 13R. IVlodel F1 • Residential· Sprinklers Pendent Horizontal Sidewall 8uI1eur, 139r, Recessed Horizontal Sidewall Recessed Pendent The Reliable Automatic Sprinkler Co., Inc., 525 North MacOuesten Parkway, Mount Vernon. New York 10552 OJ :::: w c.o z M =1 /RES 16, F1 /RES 18, F1 /RES 20, F1 /RES 2 and i::-1 /RES Penaent Res_idential Spri. Jers Installation Wrench )del D Sprinkler Wrench Approval Organizations Underwriters Laboratories. Inc. Underwriters' Laboratories of Canada N.Y.C. BS&A 587-75-SA (F1/RES) N.Y.C. MEA 258-93-E (F1/RES 2. F1/RES 18) Te,ehnical Data Thread Temp. Maximum Maximum Sprinkler ' Size Rating Pressure , Celling Temp. Height ½" NPT : 155°F , 175 ps1g i 100°F 2.2" 1/," NPT ! l75°FP1 175 psig I 150°F 2.2" !1lOnly F1/RES 18. ULI Listed Only Model F1/RES 16 Model F1/RES/F2, F1/RES2/F2, F1/RES 16/F1 or F2, F1/RES 18/F2 and F1/RES 20/F1 or F2 Recessed Pendent Residential Sprinklers Installation Wrench Model GFR 1 Sprinkler Wrench Approval Organizations Underwriters Laboratories. Inc. Underwriters' Laboratories of Canada N.Y.C. BS&A 587-75-SA (F1/RES/F2) Model F1/RES 18 Model F1 /RES 2 __,_? 1/4" HQl( Q:...7 ? -I l~rf(.' .[}.,I--, ; ,· -.J,.---I i. / 1~-' Model F1/RES N.Y.C. MEA 258-93-E (F1/RES 2/F2, F1/RES 18/F2) : : _ ls~ast~t, · ,1: 1 J -,·, •/r otouc,• 1------·-1 / I ' I Technical Data fhread Temp. Maximum Maximum ! S~rlnkler Size Rating Pressure Celling Temp. i eight I ½" NPT 155°F 175 psig 100°F ! 2.2" I ½" NPT 175°F(1l 175 psig 150°F : 2.2" <1f Only F1/RES 18/F2 and F1/RES 20/F1 or F2. ULI Listed Only. <2> Refer to escutcheon data table for dimensions. Installation Data (Pendent/Recessed Pendent) i Nominal I Orifice : Temp . Sprinkler Size I Rating ••K" Spacing Model In. : •F I Factor • ft. F1/RES 16 12 X 12 & ¾ 155 3.0 14 X 14 Ft/RES 16/F1 or F2 Ft/RES tall I 155 14 X 14 & ¾ & 3.9 16x 16 Ft/RES 18/F2<1l 175 18 JC 18 F1/RES 20 155 & 1/,6 & 4.2 20 X20 F 1 /RES 20/F 1 or F2 17 12 X 12 Fl/RES 2 14 X 14 & 1/,£ 155 4.2 16x 16 F1/RES 2/F2 18x 18 20x 20 12 X 12 F1/RES/F2 J', 155 5.6 14 X 14 16 X 16 12x 12 Fl/AES 155 14 X 14 5.6 16 X 16 18 X 18 1 1' 9 fool m, nimum soac 1ng required oetween sprinklers Max. Olatance To Wall ft. 6 7 6 7 B 9 1 10 6 7 8 9 10 6 7 8 6 7 8 9 2. I (7 • I '-r..-t-+-------'-(tj r,;,cr or nm;yc ro ClN..wc:=IJ,,u(~SIQN r-1 ! ! +------;; ./T/Jl l)jA Minimum Required Sprinkler Discharge Single Sprlnkler ! Two Or More Sprinklers Flow PresSl.nt ' Flow Ea. Pf9:s!KnEa m 9 8 7.1 10 111 8 7.1 10.5 7.2 7.2 12 9.5 7.2 12 9.5 10.5 7.2 15 14.8 10.5 7.2 16 14.5 14 11.1 12 8.2 11.5 7.5 13 9.6 11.5 7.5 15 12.8 12 8.2 17 16.4 15 12.8 19 205 17 164 20 12.8 15 7.2 20 12.8 15 7.2 20 12 6 20 12 e 20 128 15 7.2 20 128 15 7,2 20 12.8 20 12.8 28 250 22 154 Model F1 /RES and F ... -IES/3 Horizontal Sidewall Rb.sident~al Sprinklers Installation Wrench Model D Sprinkler Wrench Approval Organizations Underwriters Laboratories, Inc. Underwriters' Laboratories of Canada N.Y.C. MEA 258-93-E (F1/RES, F1/RES/3) T ·-I na.t!!:11 .. Thread Temp. Maximum Maximum Size Rating Pressure Celling Temp. ½"NPT 155°F 175 psig 100°F ½"NPT 175°FP) 175 psig 150°F (l) Only F1/RES/3 UL and ULC Listed Only. Model F1 IRES/3 Model F11RES Sprinkler Length 2 75" 2.75" Model F1/RES/F2 and F1/RES 3/F2 Recessed Horizontal Sidewall Residential Sprinklers Installation Wrench Model GFR 1 Sprinkler Wrench Approval Organizations Underwriters Laboratories, Inc. Underwriters' Laboratories of Canada , NYC. MEA 258-93-E {F1/RES/F2, F1/RES 3/F2) Technical Data Tnread I Temp. Maximum I Maximum ·1 Sprinkler j Size Rating Pressure I Celling Temp. Length , ½" NPT 155°F 175 psig I 100°F I ½" NPT 175°F<1) 175 psig I 150°F I <1lOnly F1/RES/3/F2 ULI and ULC Listed Only. <2l Refer To Escutcheon Data Table For Dimensions. Installation Data HSW/Recessed HSW Model I i Nominal i Orifice Size (In) F1/R&ES/3 I F1/AES/3/F2 3/8 ! Fl/AES/3 i & F1/RES/3/F2 : I I 3/8 Temp Rating (•F) 155 175 (W) x (L) : Sprinkler MK" Spacing Factor ' (ft ) 3.9 3.9 12 X 12 , I 14 x 14 i i ~:: ~: !I 16x20 18 X 18 12 X 12 14 X 14 16 X 16 12 X 12 14 X 14 16 X 16 16 X 18 : 16 x 20 i I 12 X 12 I I , 14 X 14 , 16 X 16 ' r---------------- Fl/RES 155 F1/RES/F2 155 5.6 5.6 12 X 12 14 X 14 16 X 16 16 X 18 16 X 20 12 X 12 14 X 14 2.75" I 2.75" I Maximum Distance To Adjacent Wall (ft) 6 7 8 8 8 9 6 7 8 6 7 B B B 6 7 8 6 7 8 B 8 6 7 3, 1• X 1/:?" RCDUC£P 7 sec INSTAU..ATION O,UA 1ABI.C r----:;::::::::~(1/A,.-----.,.---.-J 2 1/4. HOLE lWi. r r,/ l L l-L fUfffi CDU.AR UNr#.. rlGMr AGtfNS'r sPRiN1(1_(R 'lm!NCH BOSS ~ 21/J2· °"- Minimum Required Sprinkler Dlscnarge Deflector to : CelUng Dimension i I Mln (In>· Max (In) I Single Sprinkler ! Two or More Sprinklers Flow I Pressure I Flow Ea. 1 Pressure Ea. (gpm) ! (psi) jgpm) (pal) I ! I I ' 4-6 4-6 4-6 4-6 4-6 4-6 6 -12 6-12 6-12 4-6 4-6 4-6 4-6 4-6 6 -12 6 -12 6 -12 4-6 4-6 4-6 4-6 4-6 4-6 4-6 ! 13 14 17 18 25 22 13 17 20 14 14 17 19 25 13 17 20 25 25 30 34 37 28 28 11.1 12.9 19.0 21.3 41.1 31,8 11.1 19.0 26,3 12.9 12.9 19.0 23 7 41.1 11.1 19,0 26,3 19.9 19,9 28.7 36.9 43.7 25.0 25.0 11 12 14 16.5 19.5 21 13 16 17 11 12 14 16,5 20 13 16 17 18 18 21 24 26 20 20 I I I 7.9 9.5 12.9 17.9 25,0 29.0 11.1 16.8 19.0 7,9 9,5 12,9 17.9 263 11.1 16.B 19,0 10.3 10.3 14.1 18.4 21.6 12.8 12 8 Application and Installation Model.F1 Residential Sprinklers must be installed in accordance with NFPA 13,130 or 13R. These sprinklers are approved solely for use with indoor wet pipe sprinkler systems. Model ·F1 Recessed Residential Sprinklers are to be installed only as shown. The Model F1 or Model F2 Escutcheon illustrated is the only recessed escutcheon to be used with the Model F1 Pendent or Horizontal Sidewall Residential Sprinklers. The use of any other recessed escutcheon will void all approvals on these sprinklers and negate all warranties. When installing Model F1 Residential Sprinklers use the Model D Sprinkler Wrench and when installing Model F1 Recessed Residential Sprinklers use the Model GFR 1 Sprinkler Wrench. Any other type of wrench may cause damage to these sprinklers. MoQels F 1 /RES,. F 1 /RES 2, F 1 /RES 16, F 1 /RES 18 and F1/RES 20 Pendent Residential Sprinklers shall be positioned such that the deflectors are within 1 to 4 inches from the ceiling. Finishes Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Brass Plated White Polyester Coated Bright Chrome Plated Black Plated While Painted Other finishes and colors are available on special order. Consult factory for details. Escutcheon Data Escutcheon Recessed Sprinkler Model I Model F1/RES Pendent F2 !Model F1/RES 2 Pendent F2 I ' Model F1/RES 18 Pendent F2 Model F1/RES HSW F2 I Model F 1 /RES/3 HSW F2 !Model F1/RES 16 Pendent F1 or i Model F1/RES 20 Pendent F2 Adjustment (inches) \' 12 v.: ,2 ½ ½ ½ ¾ ½ Maintenance Model F1. Residential Sprinklers sh"ould be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 130, and 13R. Do not clean sprinkler with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (Other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. ULI Listing Category Residential Automatic Sprinkler ULI Guide Number VKKW Patents US. Patent No. 5,687,914 ai:wties to the Model F1/RES 18 Pendent Sprinklers. U.S. Patent number 5,727,737 applies to the Model F1/RES/3 Horizontal Sidewall Sprinklers. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Temperature Ratiog 5. Sprinkler Finish • 6. Escutcheon Finish (where applicable) 7. Escutcheon Mqdel (F1/RES 16 and 20 Only) Note: When a Model Fi Recessed Residential Sprinkler is ordered, sprinklers and escutcheons are packaged separately. UA" Face of Fitting to Celling or Wall Dimension (inches) (Inches) '¾6 1/.s:1½6 '1/,r, Yia-1Xe 1X6 ··¾s•1Xs· 1¾6 I 1/.s·1½£ 11/,6 I ½6·1Yr6 J' I 3/,'5-1¾6 /4 I ,Yi~ 1/.5·1½0 The equIpmen1·presen1ed In lhIs bullehn Is to be installed In accordance with !he latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporauon. or other s1mItar orgami:atIons and also with the provIsIons ol governmental codes or ordmances whenever applicable. Products manufactured and distributed by Reliable have been protecung Ille and property for over 70 years. and are installed and serviced by the mos1 highly qualified and reoutabte sprinkler contractors located throughout the United States. Canada and foreign coun111es. Manufactured by Reliabl~ The Reliable Automatic Sprinkler Co., Inc. (BOO) 431-1588 Sates Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.rehablesprinkler.com Internet Address 4. Re111s1on llnes indicate updated or new data E.G. Pr1nIeo 111 USA 6199 PIN 9999970030