HomeMy WebLinkAbout111 SEQUOIA AVE; G; CBR2025-1999; PermitPrint Date: 02/05/2026 Building Permit Finaled Residential Permit CBR2025-1999Permit No: Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: 111 SEQUOIA AVE, # G, CARLSBAD, CA 92008 BLDG-Residential 2060132007 $80,360.00 Work Class: Lot #: Project #: Deck Status: Applied: Issued: 08/13/2025 10/15/2025 Finaled Close Out:02/05/2026 #of Dwelling Units: Track #: Plan #: Closed - Finaled Plan Check #: Orig. Plan Check #:Bathrooms: Final Inspection:02/02/2026Bedrooms:Construction Type: Occupant Load: Code Edition: Sprinkled: INSPECTOR:de Roggenbuke, Dirk GORDON: BALCONY REMODEL INCLUDING REPLACEMENT OF BALCONY PONY WALL WITH GLASS RAILING (E-REVIEW)Description: Project Title: Applicant: MARTIN GORDON 111 SEQUOIA AVE, # APT G CARLSBAD, CA 92008-4030 Property Owner: MARTIN GORDON 111 SEQUOIA AVE, # APT G CARLSBAD, CA 92008-4030 Contractor: GARCILASO CONSTRUCTION GRANT GARCILASO 2577 JOANN DR OCEANSIDE, CA 92056-3428(760) 631-2012 AMOUNTFEE BUILDING PLAN CHECK $211.25 DECKS/BALCONY – NEW/REPLACE $333.00 PLUMBING, MECHANICAL & ELECTRICAL PERMITS $233.00 SB1473 – GREEN BUILDING STATE STANDARDS FEE $4.00 STRONG MOTION – RESIDENTIAL (SMIP)$10.45 Total Fees:$791.70 Total Payments To Date:$791.70 Balance Due:$0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 442-339-2719 ï 760-602-8560 f ï www.carlsbadca.gov Building Division Page 1 of 1 {"Cityof Carlsbad (Cityof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION FOR CITY USE ONLY Plan Check No.: _____ _ PC Deposit: _____ _ B-1 Date: _____ _ This form shall be completed to initiate a residential building permit application. The building permit application is not a building permit. No work shall start until a building permit is duly issued. Job Address: 111 Sequoia Ave Carlsbad CA 92008 Unit#: G APN: 2060132007 ---- Description of Work: Balcony remodel including replacement of balcony pony wall with glass railing Project Valuation: $_8-'0,'--3_6_0 ____ Is there an active code enforcement violation on this site? D Y ~ N Are Planning permits required?: D Y D N Case File Nos.: ______________ _ Please indicate the type of application(s) requested and provide the applicable information: □ New SF: Living SF, ____ ~• Deck SF,----~· Patio SF,----~· Garage SF,----~ Is this to create a new ADU/JADU? □ Y □ N. New fireplace? □ Y □ N. l!!!!I Remodel: 213 SF of affected area . ------Is the area a conversion or change of use? □ Y ~ N. □ Pool/Spa: ______ SF . Additional Gas or Electrical Features? ____________ _ □ Solar: ____ KW, ____ Modules. Mounted: □ Roof □ Ground. Tilt: □ Y □ N. RMA: □ Y □ N. Battery: □ Y □ N. Panel Upgrade: □ Y □ N. Electric Meter Number:--~---~~-----,--- 1!!!!1 Plumbing, Mechanical, Electrical: Move one electrical outlet and add one electrical outlet in balcony □ Other: ________________________________ _ APPLICANT (PRIMARY CONTACT): Name: Martin Gordon Address: 111 Sequoia Ave Unit G City: Carlsbad State: CA Zip: 92008 Phone: (760)815-8639 Email: martin.scott.gordon@gmail.com DESIGN PROFESSIONAL: Name: Mark L. McKinney, Architect AIA Address: 12146 Lomica Dr City: San Diego State: CA Zip: 92128 Phone: (858)485-8787 Email: mckinneyarchitect@hotmail.com State License: C26548 ------------ PROPERTY OWNER: Name: Martin Gordon Address: 111 Sequoia Ave Unit G City: Carlsbad State: CA Zip: 92008 Phone: (760)815-8639 Email: martin.scott.gordon@gmail.com CONTRACTOR: Name: Garcilaso Construction LLC Address: 2577 Joann Dr. City: Oceanside State: CA Zip: 92056 Phone: (760)631-2012 Email : g.garcilaso@hotmail.com CSLB License#: 893920 Class: B --- City Business License#: _ln~p_ro~g'-re_s_s ___ _ Billing Party: ~·Applicant □ Property Owner □ Contractor □ Other: _____________ _ Page 1 of 4 rev 11/24 The construction, addition, or alteration of buildings is governed by the California Contractors License Law (commencing with Business Professions Code section 7000). The law has an exemption that allows a person who is not a California Licensed Contractor to construct a single-family residential structure and engage in home improvements and repairs, provided they meet certain requirements. (Form 8-61 provides information about the requirements that apply to Owner-Builders makes you aware of your responsibilities and possible risk you may incur by having a permit issued to an Owner-Builder.) Permits for multi-family projects are only to be issued to California Licensed Contractors. Refer to Form 8-16 for other frequently asked questions. APPLICANT (PROPERTY OWNER, CONTRACTOR, OR AGENT) CERTIFICATIONS: CHECK EACH BOX [l] [l] [l] [l] [l] [l] I/We certify that I/we a legal right, interest, or entitlement to the use of the property that is the subject of this application. I/We understand that State law mandates the Applicant to provide an estimated value of all work proposed (B-29 form). I/We hereby certify the construction valuation provided is accurate and includes all proposed work such as all structural work, finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, labor costs, and all permanent equipment and systems. If the valuation is underestimated, the permit may be denied, unless the Applicant can show detailed estimates to meet the approval of the Building Official. If the Applicant is not the Property Owner, both the Property Owner an<;! Applicant (authorized Contractor or authorized Agent of the Property Owner/Contractor) must sign below. By signing this declaration, the Property Owner authorizes the Applicant listed in this application to act as the Property Owner's Agent on all matters before the city pertaining to development on this property. I/We understand that State law requires construction to be done by a Licensed Contractor and the Property Owner may apply for an Owner-Builder permit under an exemption from the law. □ A. If the Contractor is the Applicant, the License Contractor Declaration on page· 4 must be completed. D B. If the Applicant is an Owner-Builder, an Owner-Builder affidavit is required and must be submitted (Form 8-61 ). The city will not issue a building permit until this form has been submitted. The License Contractor Declaration on page 4 does not need to be submitted. I/We have read this application form in its entirety and reviewed the building permit application and the information I/we h,we provided is true and correct to the best of our knowledge. Grade lines as shown on drawings accompanying this application are assumed to be correct. This certifies that the description of the project and all the plans and supporting documentation; including the location and labeling of all existing and proposed buildings, structures, access roads, and utilities and easements; are accurate in all material respects as of the date when made. I/We understand that it is my responsibility to ensure that statements and representations are not misleading. I/We agree to promptly remove, correct, or add information as needed to correct any misleading or materially inaccurate information. I/We understand that any misstatement or omission of the requested information or of any information subsequently requested might be grounds for rejecting the application, denying the application, suspending or revoking a permit issued on the basis of these or subsequent representations, or for the seeking of such other and further relief as deemed appropriate by the City of Carlsbad. If a digital submittal is made or required, I/we certify that the submittal package includes digital files that follow the city's electronic submissions standards.) Failure to submi.t correctly formatted electronic files may result in the submittal being returned, which will delay intake and/or review. Page 2 of 4 rev 11/24 [Z] [Z] [Z] [Z] [Z] I/We certify that I am (we are) aware of all permit requirements and will not willfully deviate from the approved plan. I/We agree to comply with all applicable city and county ordinances and state laws relating to building construction. I/We assume full responsibility for the satisfactory completion of all work authorized under the permit(s), including work performed prior to assuming control. After construction begins, I/we understand that a height certification, pad certification, or boundary certification may need to be submitted to the Building Inspector, when required. I understand that a building permit application will expire If a permit has not been issued/obtained within one year from the application date (original filing date), unless an extension of time has been granted (Form 8-25). With some limited exceptions, if a building permit application expires and there is interest in proceeding with the same project, a new application will be required and the project will be subject to new fees and regulations that are in effect at the time the new application is submitted. After submitting the application, the Billing Party designated as part of the application will be sent future city invoices for above referenced building permit(s). I understand that if a permit fee or development impact fee refund is issued, the check will be mailed to the financial responsible party (the actual person or company that paid the invoice). If the information on file for the financially responsible party is outdated or inaccurate, it must be corrected before the refund can be sent. Form 8-498 may be completed to update the financially responsible party's contact information. I/We agree to waive, release, and discharge the City of Carlsbad ("City") and its officers, elected or appointed officials, employees, volunteers and agents (the "Indemnified Parties") from all claims and demands, rights and causes of action of any kind with respect to the building permit application, the purpose of which is to challenge, attack set aside, void, modify, or annu I the approval or denial of the application, or the processing thereof, except liability caused by the Indemnified Parties' sole negligence or willful misconduct, in which case the indemnity received by the city shall be reduced by the amount: (a) that the city's active negiigence contributed to the liability on a comparative basis; or (b) such othe~ amount as may be required. by law. This obligation is effective without reference to the existence or applicability of any insurance coverages which may have been required by city or any additional insured endorsements which may extend to Indemnified Parties. Property Owner(s) and Applicant, on behalf of themselves and all parties claiming under or through them, waive all rights of subrogation and contribution against the Indemnified Parties while acting within the scope of their duties, from all claims, losses and liabilities arising out of or incident to activities or operations performed, regardless of any prior, concurrent or subsequent passive negligence by the Indemnified Parties . By signing below, I acknowledge that I have completely read, understand, and agree to the declarations above an~accep~~r set forth herein. {This section must be signed by both p~rt,~i not the same individual.) Ma 'S"co t Gordon Digitally signed by Martin Scott Gordon 1 ~ Z--5 Date: 2025.08.06 05:09:49 -07'00' Date: 8 6 025 -----------Signature of Property Owner Date: -----------Signature of Applicant Page 3 of 4 rev 11/24 CONTRACTOR CERTIFICATIONS: '"";:.r dJ License Contractor Declarations I hereby affirm under penalty of perjury that I am a licensed under provisions of Chapter 9 (commencing with section 7000) of Division 3 of the Business and Professions Code, and the license is in full force and effect. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. Place a check mark next to the declaration regarding the workers' compensation coverage that applies. Check only one (A), (B), or (C): □ A. I have and will maintain a certificate of consent to self-insure for workers' compensation. issueci by the Director of Industrial Relations as provided for by Sect ion 3700 of the Labor Code, for the performance of the work for which this permit is isyied. f;$ B. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issu • • • • ~ □ C. I , shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forth with comply with those provisions. D I hereby affirm under penalty of perjury that there is a construction lending agency for the J performance of the work for which this permit is issued (Civil Code section 3097). If not using a construction lending agency write N/A: Lender: __________________ _ I understand that I will need a current Carlsbad business license to obtain the building permit. By signing below, I acknowledge that I have completely read, understand, and agree to the declarations above II term s forth herein. FOR CITY USE ONLY Receipt Acknowledgement: ____________ _ Date:. _________ _ BUILDING STAFF Page 4 of4 rev 11/24 Building Permit Inspection History Finaled PERMIT INSPECTION HISTORY for (CBR2025-1999) BLDG-Residential 08/13/2025Application Date:Permit Type:Owner:MARTIN GORDON Deck 10/15/2025Work Class:Issue Date:Subdivision:CARLSBAD TCT#84-18 07/06/2026Expiration Date:Status: IVR Number: 65334 Closed - Finaled 111 SEQUOIA AVE, # G CARLSBAD, CA 92008 Address: Scheduled Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection InspectionActual Start Date 12/02/2025 12/02/2025 BLDG-14 Frame/Steel/Bolting/We lding (Decks) 302310-2025 Partial Pass Dirk de Roggenbuke Reinspection Incomplete COMMENTS PassedChecklist Item BLDG-Building Deficiency 12/2/25 partial pending door/ widow framing Yes BLDG-15 Roof/ReRoof (Patio) 302464-2025 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes 01/07/2026 01/07/2026 BLDG-14 Frame/Steel/Bolting/We lding (Decks) 305090-2026 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency 12/2/25 partial pending door/ widow framing Yes BLDG-16 Insulation 305266-2026 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes BLDG-17 Interior Lath/Drywall 305267-2026 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes BLDG-18 Exterior Lath/Drywall 305268-2026 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes BLDG-34 Rough Electrical 305265-2026 Passed Dirk de Roggenbuke Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes 02/02/2026 02/02/2026 BLDG-Final Inspection 307282-2026 Passed Dirk de Roggenbuke Complete Thursday, February 5, 2026 Page 1 of 2 {cityof Carlsbad PERMIT INSPECTION HISTORY for (CBR2025-1999) BLDG-Residential 08/13/2025Application Date:Permit Type:Owner:MARTIN GORDON Deck 10/15/2025Work Class:Issue Date:Subdivision:CARLSBAD TCT#84-18 07/06/2026Expiration Date:Status: IVR Number: 65334 Closed - Finaled 111 SEQUOIA AVE, # G CARLSBAD, CA 92008 Address: Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection InspectionActual Start Date COMMENTS PassedChecklist Item BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Thursday, February 5, 2026 Page 2 of 2 [1 1cc EVALUATION SERVICE ICC-ES Evaluation Report ESR-3563 Reissued January 2025 Subject to renewal January 2026 This report also contains: • City of LA Supplement -FL Supplement ICC-ES Evaluation Reports are not to be construed as representing aesthetics or eny other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There Is no warranty by ICC Evaluation Service, LLC, express or Implied. as to any finding or other matter In this report, or as to any product covered by the report. Cop right e 2025 ICC Evaluation Service, LLC. All rights reserved. DIVISION: 05 00 00- METALS Section: 05 52 00-Metal Railings Section: 05 73 13- Glazed Decorative Metal Railings DIVISION: 08 00 00- OPENINGS Section: 08 81 00- Glass Glazing Section: 08 88 00- Special Function Glazing REPORT HOLDER: GLASS VICE HOLDINGS USA LLC Compliance with the following codes: EVALUATION SUBJECT: GLASS VICE GLASS PANEL RAILING AND GLASS BALUSTER SYSTEMS ■2021, 2018, 2015, 2012 and 2009 /nternational Buildm 2 ■ 2021, 2018, 2015, 2012 and 2009 International Residential ■ 2021 and 2018 International Sw1mmm Properties evaluated: ■ Structural ■ Durability u l:: C' The Glass Vice Glass Panel Railing and Glass Baluster Syst ~ n4 SET Of nE Pt.AAS ANO SPE'., FICATlONS MUIT 8E KEPT ON THE Jv8 snt AT ~Ll TIMES N«J IT 1$ UNLAWFUL TO MAl<E ~y "H.'NQES OR ALTWTIONS W1Tt-0Vl PERMISSION FROM TME. CITY OCCUPANCV Of: STRVCTURfaS1 IS NOl PEM11TTED UNTIL FINAL ~O\i/\1. 1S GRANTED BY ALL AJ>PllCASlE OEPAJr~MENTS interior and exterior use in residential, commercial, and indus or guards along balconies, porches, mezzanines, stairs, and similar locations except where vehicle impact resistance is required. The system may also be used as a pool or spa barrier. The system is compatible with all construction types. Use in W ind-borne Debris Regions must be In accordance with Section 3.4 of this report. The Glass Vice Glass Panel Railing and Glass Baluster Systems described in this report must be constructed using monolithic tempered or laminated tempered glass within the limitations specified in this report. See Section 4.1.5.1 in this report for limitations on the installation of laminated tempered glass. The use of 9/,s-inch (14.3 mm) and 5/a-inch (15.87 mm) laminated tempered glass panel and anchorage systems have not been evaluated for use as a guard or handrail system where the 50 plf (0.73 kN/m) loading Page 1 of 31 ESR-3563 Page 2 of 31 -------------l[~tt5'1-J u oc1w,oc•y1.:ccp1cdand rru~1cd !-----------.....;;'------ is required by 2021 IBC Section 1607.9.1 (2018, 2015 and 2012 IBC Section 1607.8.1; 2009 IBC Section 1607.7.1). The system may be installed up to a total height of 42 inches (106.7 cm) without a top rail or handrail when 9/,s-inch thick (14.3 mm) or 5!a-inch thick (15.87 mm) laminated tempered glass panels up to 41 inches (104.1 cm) in height with an interlayer meeting the requirements of Section 3.2.1 are used. Installation without a top rail complies with the Exceptions noted in IBC Section 2407.1.2 and 2021 and 2018 IRC Section R308.4.4.1. This use is limited to installations under the IRC or in one and two family dwellings under the IBC where the 50 plf (0.73 kN/m) live load is not applicable. The system may also be installed without a top rail or handrail with monolithic or laminated glass panels when use as a spa or pool barrier and installed in accordance with Section 4.2.6. This use is limited to configurations in which the system is not required to function as a guard or handrail. 3.0 DESCRIPTION 3.1 General: The Glass Vice Glass Panel Railing and Glass Baluster Systems allow for the construction of frameless glass balustrade guards, wind breaks and pool fences. The systems include the monolithic tempered glass (to be provided by others) or laminated tempered glass (to be provided by others), the railing, the glass clamp, the glass bracket, and the fastening into the substrate. The Glass Vice system uses a proprietary glass clamp cast from Duplex 2205 (UNS S32205) or 316 stainless steel, complying with ASTM A890/A890M, to anchor and fully support ½-inch (12.7 mm) or 5!a-inch (15.87 mm) monolithic tempered glass or, 9/,s-inch (14.3 mm) or %-inch (15.87 mm) laminated tempered glass balustrades. Monolithic tempered glass installations may have a stainless steel handrail located between 34 and 42 inches (864 and 1067 mm) above floor surface as appropriate for the installation. A handrail or guard must be installed when the monolithic tempered glass balustrade is required for fall protection to comply with IBC 2407.1 . The laminated tempered glass is limited to installations where a handrail or guard is not required as noted in Section 2.0 of this report. The balustrade system must be anchored into wood, concrete or steel substrates with a Glass Vice clamp and appropriate fasteners. The clamp is available in various configurations (See Table 1 and Figures 4 through 16 in this report) based on the substrate and location of attachment. The various clamps are supplied with the Glass Vice fasteners and must be used for the installation. The Glass Vice clamps are the same for all glass thicknesses with the bearing gasket thickness matched to the glass thickness. The glass moment strengths are indicated in Tables 2 and ~ of this report for the specified glass type and thickness. 3.2 Material: The glass must be fully tempered glass complying with ASTM C 1048, ANSI 297 .1 and CPSC 16 CFR 1201 (procured separately). The minimum thickness of the tempered glass for each guard system is as required for the loading conditions; refer to Tables 2 and ~ of this report. The handrail is manufactured out of stainless steel material and is 11/2-inch by 1-inch (38.1 mm by 25.4 mm) tube. The handrail must be connected to the glass balustrade with a proprietary bracket made from 316 stainless steel supplied by Glass Vice. The handrail bracket consists of a bent 9/,s-inch (14.3 mm) diameter 316 stainless steel bar with attached mounting flanges and a mounting plate on the opposite face of the glass connected together with one M8 by 20 mm countersunk stainless steel screw. The Glass Vice glass clamp is composed of an adjustable clamping system which is made up of duplex 2205 or 316 stainless steel clamp, 8 mm diameter adjustable screws, 3 mm by 140 mm Polyethylene plastic strips, 8 mm by 8 mm by 140 mm stainless steel bars, and an 8 mm by 12 mm by 40 mm stainless steel bar at the bottom center of clamp cavity. The clamp is approximately 71/16 inches (179 mm) in height. The base is available in various configurations as described in this report, depending on the substrate, concrete, wood or steel substrate and the attachment to the surface or fascia. Connection to the top of a concrete substrate uses two M10 stainless steel (SS) threaded rods, ISO 3506-1 Class A4, which must be installed into the concrete substrate with Hilti HIT-RE 500 V3 adhesive (ESR-3814). See Figures 4 through § and Figure 10, as applicable, in this report. Installation of the rods must comply with the installation details noted in ESR-3814. For top installation into wood, a stainless steel adaptor plate (American Baseplate SLDPRT) must be used for the base. The adaptor plate is 316 stainless steel, machined from 0.394-inch (10 mm) flat bar and anchored to the wood with four 3/s-inch (9.5 mm) SS lag screws, all fasteners are supplied with the clamp by Glass Vice. ESR-3563 Page 3 of 31 -------------l[tftpf1 Moct 1Yidc'1Aeccp1ca,ndTM1ca !-------------=~--- For fascia mounting installation, the Glass Vice is available as an architectural clamp made of cast stainless steel with a stainless steel cover to conceal the two mounting bolts. The architectural clamp is available for use with concrete, wood and steel substrates for balustrades installed per the IBC and IRC. The architectural clamp consists of a tapered extension leg 6¼ inches (159 mm) from the base for fascia mount. To mount to wood fascia, flat bar standoffs or threaded standoff nuts must be used with the two mounting bolts or screws, between the clamp leg extension and the fascia substrate as shown in Figures 11 , 12 and 16. To mount to metal or concrete substrates, flat bar standoffs or round standoffs of minimum 0.394 inch (10 mm) in diameter must be used with the two mounting bolts between the clamp leg extension and the fascia substrate as shown in Figures 10 and 15. 3.2.1 Laminated Tempered Glass: The laminated tempered glass must be fully tempered laminated glass complying with ASTM C1172, ANSI Z97.1 and CPSC 16 CFR 1201 (glass procured separately-not supplied by Glass Vice). The fully laminated tempered glass used in the fabrication must comply with ASTM C1048. The interlayer must be 0.06-inch (1.54 mm) thick, and must have a minimum shear modulus of 1640 psi (11 .3 MPa) for T s 122°F (50°C) and a minimum ultimate tensile strength of 5000 psi (34.5 MPa) for T s 122°F (50°C). The minimum glass thicknesses specified in ASTM C1036 and C1300 are modified as specified in this report. All glass edges must be polished. 3.2.1 .1 The 9/,s-inch (14.3mm) laminated tempered glass must be made from ¼-inch (6 mm) nominal tempered glass with a minimum true thickness of 0.225 inch (5.72 mm). The overall true thickness of the laminated tempered glass must be between 0.510-inch (12.95 mm) minimum and 0.560-inch (14.22 mm) maximum. Evidence of compliance with these requirements must be submitted to the code official. 3.2.1.2 The 5/a-inch (15.87 mm) laminated tempered glass must be made from one ply of ¼-inch (6 mm) nominal tempered glass with a minimum true thickness of 0.225 inch (5.72 mm) and 5/16-inch (8 mm) nominal tempered glass. The overall true thickness of the laminated tempered glass must be between 0.577 inch (14.65 mm) minimum and 0.625 inch (15.87 mm) maximum. Evidence of compliance with these requirements must be submitted to the code official. 3.3 Durability: The materials incorporated in the system described in this report are inherently corrosion-resistant. The material type specified must be appropriate for the environment of the installation. Information verifying the durability must be submitted to the code official, when requested. 3.4 WINDBORNE DEBRIS REGIONS: The system has been evaluated for use in windborne debris regions under the following conditions: 1. The system must be installed without a top rail or handrail at a total height of less than or equal to 42 inches (106.7 cm) with 9/16-inch thick (14.3 mm) or 5/8-inch thick (15.87 mm) laminated tempered glass panels up to 41 inches (104.1 cm) in height with an interlayer meeting the requirements of Section 3.2.1. 2. The system must be limited to installations in one and two family dwellings under the IBC where the 50 plf (0.73 kN/m) live load is not applicable or installations under the IRC. 4.0 uESICN AND INbTALLATIO 4.1 Design: 4.1 .1 Loading: The applicable project-specific loads must be identified. Minimum required loads are one of the following: ■ 50 plf (0.73kN/m) live load on the top rail or handrail in any direction ■ 200 lb (0.89kN) live load on the top rail or handrail in any direction ■ 50 lb (0.22kN) live load on one square foot at any location perpendicular to the glass balustrade Deflection of the top rail when subjected to a 200-pound (0.89kN) concentrated live load is less than 1 inch (25.4 mm) for the following system configurations: ■ System height of 36 inches (91.4 cm) or less for 9'1s-inch-thlck (14.3 mm) laminate glass panels. ■ System height of 42-inches (106.7 cm) or less for ½-inch thick (12.7 mm) monolithic glass panels or 5/a-inch thick (15.87 mm) laminate glass panels. ■ System height of 48 inches (121 .9 cm) or less for 5/a-inch thick (15.87 mm) monolithic glass panels Deflection of the top rail when subjected to a 50 plf (. 73kN/m) live load is less than 1 inch (25.4mm) for the following system configurations: ESR-3563 Page 4 of 31 -------------l[~tq3'J IAOCt\V,dc'yl,:et,prcdondTru~•cdl---------------- ■ System height of 24-inches (61 cm) or less for 1/2-inch (12.7 mm) thick monolithic glass panels. ■ System height of 42-inches (106.7 cm) or less for 51a-inch thick (15.87 mm) monolithic glass panels. Glass panel widths are limited to the maximum allowable width noted in Table 5 when consideration of the 50 plf (0. 73KN/m) live load is required. The required wind load must be determined by a qualified design professional based on the project-specific conditions, taking into account the balustrade location on the structure, and must not exceed the values shown in Tables 1, i and ~ of this report, as applicable. For installations in accordance with the one and two family dwellings under the IBC and installations in accordance with the IRC, the 50 plf (0.73 kN/m) top rail load is not applicable. 4.1.2 Monolithic Tempered Glass Balustrade System : The glass thickness, panel size and system height for the ½,-inch (12.7 mm) and 5/e-inch (15.87 mm) monolithic tempered glass must be designed for the loading conditions, see Table 2 in this report. The required spacing between the glass lites must be 25/32-inch (20 mm) minimum to 13/16-inch (30 mm) maximum for installation of the handrail brackets. A handrail or top rail must be installed with the monolithic tempered glass balustrade system unless installed as noted in Section 4.2.6 of this report. 4.1.3 Glass Vice Glass Clamp: The Glass Vice Glass Clamp and fasteners that are required for each mounting option are shown in Table 1 of this report. The Glass Vice Glass Clamp must be installed in accordance with the manufacturer's published installation instructions and this report. 4.1.4 Holes and Notches for Monolithic Tempered Glass: Holes and notches must not be located within the first third of the balustrade height from the base. Holes and notches must conform to ASTM C1048. Holes or notches located within the first third of the balustrade height from the base shoe are outside the scope of this report. 4.1.5 Laminated Tempered Glass: 4.1.5.1 Laminated Tempered Glass Loading: Installation of the laminated tempered glass with a required handrail or guard has not been evaluated. Therefore, installation of the laminated tempered glass is limited to locations where the design loading condition is either wind load alone or 200-pound (0.89 kN ) concentrated load, and the 50 pit (0.73 kn/m) handrail load is not applicable. Maximum allowable wind loads are as indicated in Table 3 of this report. Installation of laminated tempered glass with the handrail brackets is outside the scope of this report. 4.1.5.2 Laminated Glass Baluster System: The glass thickness, panel size and system height must be as indicated in Tables 3 and 1 of this report. The required spacing between the glass lites is 25132 inch (20 mm) minimum to 13/16 inch (30 mm) maximum for installation of the H-bracket (see Figure 19 in this report). When required to support the 200 lb (0.89 kN) concentrated load, the adjacent lites must be connected together with the supplied H-bracket installed within 4 inches (102 mm) from the top edge of the glass. Corner lites must be connected together with the supplied corner H-bracket. The end lites must be attached to a supporting structure or post capable of supporting 200 pounds (0.89kN) using the supplied terminal bracket (see Figure 18 in this report). The connection between glass lites is not required when designed for wind load only and a 2-inch (51 mm) minimum gap between lites is maintained. 4.1 .5.3 Mixed Panel Widths: Glass panels of different widths are permitted with the allowable wind load based on the longest glass panel or for the specific wind load on each panel. 4.1.5.4 Holes and Notches: Holes and notches in the laminated tempered glass are outside the scope of this report. 4.2 Installation: 4.2.1 General: Installation of the Glass Vice glass panel railing and guards must comply with the manufacturer's published instructions, this report and 2021 IBC Sections 1015 and 1607.9.1; 2018 and 2015 IBC Sections 1015 and 1607.8.1; 2012 IBC Sections 1013 and 1607.8.1; or 2009 IBC Sections 1013 and 1607.7.1, as applicable. Handrails must comply with 2021 , 2018 and 2015 IBC Section 1014; 2012 and 2009 IBC Section 1012; or 2021 , 2018, 2015, 2012 and 2009 IRC Section R311.7.8, as applicable. Glass lite dimensions for the monolithic tempered glass must be within the limits shown in Figure 1 of this report for ½-inch (12. 7 mm) glass and Figure 2 of this report for 5/e-inch (15.87 mm) glass. 4.2.2 Installation of Glass Vice Clamp to Concrete: 4.2.2.1 Concrete strength, condition and minimum dimensions must be as indicated in Table 1 of this report for the specific mounting option. For cracked concrete condition, the mounting option used must be indicated as cracked concrete in Table 1 of this report. Uncracked concrete condition may use any of the concrete mounting options in Table 1 of this report. 4.2.2.2 Surface Mounting: The Glass Vice clamps must be located as shown in Figure 1 of this report. Before attachment of any of the interchangeable bases, a layer of protective lanolin must be applied between the Glass Vice glass clamp and the base. 4.2.2.3 Two holes must be drilled into concrete for the installation of the glass vice clamp. The center line of each hole must not be closer than 2.36 inches (60 mm) from the edge of the slab and no less than 55/8 inch (143 mm) from the slab end. The holes must be between 12 mm (15/32 inch} and 20 mm (25'32 inch) in diameter and drilled to the required depth based on the installation option. After cleaning the holes, each hole must be filled with Hilti-HIT-RE 500 V3 adhesive. Installation must be into dry holes only and for use in temperature range A (130°F short-term maximum and 110°F maximum long-term temperature). Hole cleaning and adhesive installation must comply with the manufacturer's published installation instructions and ESR-3814. Mounting options 1 a-e in Table 1 of this report which do not involve installation of nuts on the inserted rod. Special inspection is required for installation of adhesive anchors, as noted in ESR-3814. 4.2.2.4 Fascia Mounting: When fascia mounted to a slab edge, beam, wall, or similar item the minimum concrete slab face thickness must be at least 71/8 inches (181 mm) and width perpendicular to the face must be at least 83/4 inches (222 mm). Clamps must be a minimum of 55/8 inches (143 mm) from the outside slab corner. The Architectural Bracket must be used and the clamp nuts for the 1 OM SS threaded rods insert must be tightened to 10 lb-ft torque (reduced torque installation). Special inspection is required for installation of adhesive anchors, as noted in ESR-3814. 4.2.3 Installation of Glass Vice Clamp to Wood: Wood may have a moisture content over 19 percent at the time of fabrication and in service and must be a species and grade with specific gravity greater than 0.43 or 0.50 as specified for the mounting option. Supporting wood structure must be constructed to support the imposed moments from the Glass Vice Clamps. In lieu of calculating the imposed loads, the structure may be designed for the mounting option to resist the moment strength shown in Table 2 of this report, plus dead load. 4.2.4 Installation of Glass Vice Clamp to Steel: Supporting steel member must be constructed to support the imposed moments from the Glass Vice Clamps. In lieu of calculating the imposed loads, the member may be designed for the mounting option to resist the moment strength shown in Table 1 of this report, plus dead load. 4.2.5 Handrail Installation (monolithic tempered glass): Where required to provide fall protection , along stairs or other locations requiring an installed handrail, the handrail must be installed at the required height. 4.2.5.1 Handrails must be supported using the proprietary stainless steel clamp bracket assembly, shown in Figures 1 and i of this report, installed at the joints between the glass lites and at the ends as shown in Figure 17 of this report. At the balustrade end, the handrail must be attached to a structure, free standing wall or post of sufficient strength, able to support 200 lbs (0.89 kN) concentrated horizontal shear load, using the termination brackets In Figure 17 and screws (not included), of a type appropriate for the supporting material. 4.2.5.2 Handrails must be installed no higher from the bottom of the glass to the top of the handrail than: 42 inches (1067 mm) for 5/s-inch (15.87 mm) glass in any occupancy requiring 50 plf (0.73 kN/m) live load. 48 inches (1219 mm) for %-inch (15.87 mm) glass in occupancy R3 (IRC) and one and two family dwellings under the IBC where the 50 plf (0.73 kN/m) live load is not applicable. 23 inches (584 mm) for ½-inch (12.7 mm) glass in any occupancy requiring 50 plf (0.73 kN/m) live load. 41 inches (1041 mm) for ½-inch (12.7 mm) glass in occupancy R3 (IRC) and one and two family dwellings under the IBC where the50 plf (0.73 kN/m) live load is not applicable. 4.2.5.3 Handrail brackets are designed for use with a square, rectangular or flat bottom cross section with minimum 15/8-inch (41 mm) width complying with the dimensional and structural requirements of 2021 , 2018 and 2015 IBC Section 1014 (2012 and 2009 IBC Section 1012), IRC R311 .7.8.3. 4.2.6 Pool or Spa Barrier Applications: When installed as a pool or spa barrier in compliance with 2021 or 2018 ISPSC Section 305 and 2015, 2012, and 2009 IBC Section 3109.4.1 , the top of glass must be a minimum ESR-3563 Page 6 of 31 -------------l[~t;Q\J Most W1delyAcc,p1edandTMted !---------------"----- of 48 inches (1219 mm) above grade on the side facing away from the pool. Minimum glass thickness shall be 5!e inch (15.87 mm) nominal , monolithic or laminated, tempered glass. Maximum lite width must comply with the allowable width shown in Figure 3 of this report and for the mounting option used for the design wind loads per Tables 2 and ~ of this report, as applicable. Where a handrail is required, the monolithic glass panels must be limited to the widths outlined in Table 5, and the handrail must be installed on the pool side at 34 inches (864 mm) to 42 inches (1067 mm) above the walking surface. Where a handrail or guard is not installed, the glass joints must be connected together with glass H brackets at 42 inches (1067 mm) above the walking surface. Refer to Figure 3 of this report. For installations with a handrail at a height of up to 42 inches (1067 mm), system deflection for a 50 plf (0.73KN/m) live load applied to the handrail is less than one inch (25.4 mm). A 50 pit (0.73KN/m) live load applied to the top of the panel results in a deflection of 1.2 inches (30.5 mm). 5 0 CONDITION4) OF USE · The Glass Vice Glass Panel Railing and Glass Baluster Systems described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The product is limited to installation where it is not subjected to vehicle impacts. 5.2 Installation must comply with this report and the manufacturer's published installation instructions. When the manufacturer's instructions are in conflict with this report, this report shall govern. 5.3 All glass must be fully tempered, fabricated, and inspected in accordance with ASTM C1 048. Laminated tempered glass must also comply with ASTM C1172. The glass fabricator must provide certification of compliance with Section 2407.1 of the IBC and ASTM C1048. Glass must be procured directly from a qualified glass fabricator and is not produced or supplied by Glass Vice USA LLC. 5.4 The supporting structure must be designed and constructed to support the loads imposed by the glass balustrade system in accordance with the applicable code. The anchorage of the panel railing and glass baluster system to the supporting structure must be as specified in this report. Drawings and design details for the Glass Vice system must be included on the construction plans submitted to the code official for approval. The drawings and details must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is constructed. 5.5 Monolithic fully tempered glass is permitted to be used in handrails and guardrails where there is not a walking surface beneath them or the walking surface is permanently protected from the risk of falling glass, as noted under the exception in Section 2407.1 of the 2021, 2018 and 2015 IBC. 5.6 Installation of the laminated tempered glass with a handrail is outside the scope of this report. See the last paragraph of Section 2.0 and Section 4.1 .5.1 of this report for additional details and limitations. 5.7 The Glass Vice Panel Railing and Balustrade Systems including anchorage components (except for the glass) are supplied by Glass Vice USA LLC. 5.8 Use of the system as a grab bar is outside of the scope of this report. 6 0 LVID NCE -.>l I:? TT 0 Data in accordance with the ICC-ES Acceptance Criteria for Glass Railing and Balustrade Systems (AC439), approved April 2019 (editorially revised August 2020). /.0 IDt:NTlrtC,AT ON 7.1 The Glass Vice Panel Railing and Glass Baluster Systems described in this report are identified by a stamp on the packaging bearing the manufacturer's name (Glass Vice) product description or part number, and the ICC-ES evaluation report number (ESR-3563). 7.2 The report holder's contact information is the following: GLASS VICE HOLDINGS USA LLC 14035 KIRKHAM WAY, SUITE 106 POWAY, CALIFORNIA 92064 (858) 539-6250 www.glassvlce.com ESR-3563 Page 7 of 31 -------------------1l1,1[,:i~~tf5i,:fS::iJL'~~~oa~1~1V~,dc'~1:_A::cc~p~1cd~illl~d~T1U~~~rcd~j----------------...;a.----- TABLE 1-GLASS VICE SYSTEMS AND CONFIGURATIONS System Mounting Option Mounting Glass Clamp Allowable Anchorage to Substrate Option Type Material Subatrate Moment Refer to attached Figure■ Number Specification st,..ngth M., and Figure (In-lb) 1a Direct Fix Vice Glass Vice Concrete· 2,166 10M SS threaded rods with 4· ernbedrnent set Hlltl HIT-RE ~ (Duplex 2205 or cracked 500 V3 per ESR-3814 316 SS) fc l! 2,500 psi 1b Direct Fix Vice Glass Vice Concrete· 2,g53 10M SS threaded rods with 4· ernbedrnent set Hlltl HIT-RE ~ (Duplex 2205 or uncracked 500 V3 per ESR-3814 316SS) fc l! 2,500 psi 1c Direct Fix Vice Glass Vice Concrete• 4,686 10M SS threaded rods with 5· embedment set Hlltl HIT-RE El9.!!ru (Duplex 2205 or cracked 500 V3 per ESR-3814 316 SS) fc l! 2,500 psi 1d Direct Fix Vice Glass Vice Concrete• 4,686 10M SS threaded rods with 5" embedment set Hlltl HIT-RE £!gyrtl (Duplex 2205 or uncracked 500 V3 per ESR-3814 316 SS) fc l'! 2,500 psi le Direct Fix Vice Glass Vice Concrete-6,902 10M SS threaded rods with 7-1/4" embedment set HIT-RE ~ ( Duplex 2205 or cracked or 500 V3 per ESR-3814 316 SS) uncrecked fc l'! 2,500 psi 2 Adaptor base Glass Vice Wood,G 4,569 M10 x 140mm (5.5") SS lag screws ~ plate (Duplex 2205 or l'! 0.43 316 SS) Any MC 3Aa Architectural Glass Vice Concrete• 4_g32 10M SS threaded rods with 7-1/2" embedment set Hlltl HIT- ~ Bracket (Duplex 2205 or cracked RE 500 V3 per ESR-3814 316 SS) f C l'! 3,000 psf 1.77" top edge distance. 3Ab Architectural Glass Vice Concrete• 5,421 10M SS threaded rods with 7-1/2" embedment set Hiltl HIT- ~ Bracket (Duplex 2205 or cracked RE 500 VJ per ESR-3814 316 SS) r c " 3,000 psi 2.165" top edge distance 3Ac Architectural Glass Vice Concrete• 4,g32 10M SS threaded rods with 7-1/2" embedment set Hllll HIT-E.!.9JlliL1.Q Bracket (Duplex 2205 or uncracked RE 500 VJ per ESR-3814 316 SS) r. i, 3,000 psi 1.77" top edge distance 3B Architectural Glass Vice Wood, Hem-10,450 10M SS bolts through wood beam with E!mla!...11 Bracket (Duplex 2205 or Fir, DFL, SP, 3'x3/8"x5 1/4' flat bar. 316 SS) SCLAny MC 3Ca Architectural Glass Vice Wood, DFL, 4,569 10mm SS Lag screws with 5.209" minimum embedment to ~ Bracket (Duplex 2205 or SP,SCL primary member with 3"x3/8"x5 1 /4' flat bar 316 SS) Any MC 3Cb Archllectural Glass Vice Wood, Hem-4,569 10mm SS Lag screws with 5.76" minimum embedment to E.l9la1l Bracket (Duplex 2205 or Fir primary member with 3"x3/8"x5 1/4" flat bar 316 SS) Any MC 3Cc Architectural Glass Vice Wood, DFL, 4,569 10mm SS Lag screws with 3.65" minimum embedment to ~ Bracket (Duplex 2205 or SP,SCL primary member with 3"x3/8"x5 1/4" flat bar 316 SS) MC s 1g% 3Cd Architectural Glass Vice Wood, Hem-4,569 10mm SS Lag screws with 4.03" minimum embedment to .EJ!IY!Lll Bracket (Duplex 2205 or Fir primary member with 3"x3/8"x5 1/4" flat bar 316 SS) MC s 19% 4 Direct Fix Vice Glass Vice Steel or 8,994 M1 0 SS bolt ASTM F738M or equivalent strength whh washer E.!slall Duplex (2205 or aluminum and nut, length as required 316 SS) Designed for loads 5 S Bracket Glass Vice Steel or 8,994 M10 SS bolt ASTM F738M or equivalent strength with washer f.lruJa..li (Duplex 2205 or aluminum and nut. length as required 316 SS) Designed for loads ESR-3563 Page 8 of 31 ------------------1[~,a-1 MOOIIV1dc'yAcccp1cdondTMlcd 1----------------~----- System Mounting Option Mounting Glau Clamp Allowable Ancho~ to Substrate Option Type Material Substrate Moment Refer to attached Flgurea Number Specification Strength M., and Figure (ln•lb) 6 Archlteclural Glass Vice Steel or 11,045 M10 SS bolt ASTM F738M or equivalent strength with washer ~ Bracket (Duplex 2205 or aluminum and nul, length as required. 316 SS) Designed for loads 3Oa Architectural Glass Vice Wood, DFL, 6,265 10mm SS Hanger Lag Screw with 3.S-minimum embedment ~ Bracket (Duplex 2205 or SP,SCL to primary member with 10mm x 25mm diameter SS threaded 316 SS) MCs 19% standoff nut. 3Db Architectural Glass Vice Wood, DFl, 6,265 10mm SS Hanger lag Screw with 5" minimum embedment to E.:rua1li Bracket (Duplex 2205 or SP, SCl primary member with 10mm x 25mm diameter SS threaded 316 SS) Any MC standoff nut. 3Dc Architectural Glass Vice Hem-Fir and 6,265 10mm SS Hanger leg Screw with 4 39" minimum ~ Bracket (Duplex 2205 or PT Wood embedment to primary member with 10mm x 25mm dlameter 316 SS) MC s 19% SS threaded standoff nut, 3Dd Architectural Glass Vice Hem-Fir and 6,265 10mm SS Hanger lag Screw with 6.27" minimum ~ Bracket (Duplex 2205 or PT Wood embedment to primary member with 10mm x 25mm diameter 316 SS) Any MC SS threaded standoff nut. SI: 1 psi = 0.006897 MPa: 1 inch = 25.4 mm ESR-3563 Page 9 of 31 ----------------1l~[~~!Sla:!it'1~/.A~o~cr~11~•,a:::c•y~A'.:ccc~p~r~cd~illl'.'.:d~rr~u~~rcd~l-------------.....:=----- TABLE 2-EQUATIONS FOR CALCULATION OF (ASD) ALLOWABLE WIND LOADS1 Eq. 1 -Allowable Wind Load (w) Load For Mounting Optlon2 Mal w = 3.3BH2 Eq. 2 -Allowable Wind Load (w) for 1/2-inch monolithic glass3 310 w =--h2 Eq. 3 -Allowable Wind Load (w) for 5/8-inch monolithic glass3 498.79 w = h2 SI: 1 Inch= 25.4 mm; 1 foot= 304.8mm; 1 plf = .0146kN/m; 1 psf = 0.0479 kN/m2 1. The systems allowable wind load must be the lesser of the allowable wind load for the selected mounting option calculated using equation 1 or the allowable wind load for the glass using equation 2, equation 3, or il!.l2!.!Ll, as applicable. 2. Mar= Mounting Option Allowable Moment Strength from ~ B ~ overall width of glass panel in feet. For systems requiring consideration of the 50plf load, refer to ~ for limitations on glass panel width. For systems that do not require consideration of the 50plf load: For ½-inch glass: 2.50 feet s B s 6.00 feet For 5/s-lnch glass: 2.50 feet s B s 6.5625 feet H = For surface mounted option: height from top of deck to top of glass in feet H = For fascia mounted option: height from bottom of mounting clamp to top of glass in feet w = ASD allowable wind load (psf). For LRFD strength design multiply wind load by 1.6. 3. h = glass height in feet w = allowable wind load (psf) for ASD. For strength design multiply wind load by 1.6 TABLE 3-(ASD) ALLOWABLE WIND LOAD FOR LAMINATED TEMPERED GLASS PANELS Glass Allowable wind load (w911e) for Allowable wind load (W51a) for Allowable wind load (W51a) for Panel 9/1e-lnch panel 35 Inches In 6/a-lnch panel 41 Inches In 5/a-lnch panel 47 Inches In Width height (psf)1•2•4•5 height (psf) 1,3,4,5,8 height (psf) 1,3,u 9 (Inches) 36 62.9 59.3 45.1 48 46.3 43.7 33.3 60 40.6 38.3 29.1 72 32.2 30.4 23.1 SI: 1 Inch= 25.4 mm; 1 psf = 0.0479 kN/m2 1. Linear interpolation for glass panel heights and widths between those shown Is permitted. 2. Wind load for glass panel height less than 35 Inches : W = W911ax (2.9167/h)2. Where h is the glass panel height in feet and Vl/9/15 = Allowable wind load for 9/16" laminated tempered glass. The minimum panel height must be limited to the minimum height outlined in ~. 3. Wind load for glass height less than 41 Inches : W = W51a x (3.4167/h)2. Where h Is the panel height In feet and W5/s = Allowable wind load for 5/s" laminated tempered glass. The minimum panel height must be limited to the minimum heig ht outlined In ~. 4. Wind load is limited to the lesser of the glass strength from ~ or the Clamp strength calculated using equation 1 In ~ of this report. 5. w = ASD allowable wind load (psf) . For LRFD strength design multiply wind load by 1.6. 6. 5/8-lnch thick laminated glass panels must meet the parameters outlined in Section 3.2.1.2. ESR-3563 Page 10 of 31 ----------------l[~!Sl=J-1 u oa111·,dc'YA:ccprcdil/1dfrurn,d j-------------....;;.----- TABLE 4-GLASS PANEL SIZES FOR LAMINATED TEMPERED GLASS Glass Thickness Min Panel Width Max Panel Width Max Panel Height Min Panel Height (Inches) (Inches) (Inches) (Inches) 9/16 Inch (14.3mm) 36 72 35 12 51a inch (15.87mm) 36 72 41 1 12 SI: 1 inch = 25.4 mm 1. Panel height of 4 ?-inches ( 119.4 cm) is permitted when the system is installed in accordance with Section 4.2.6 of this report. TABLE F-EQUATIONS FOR CALCULATION OF MAXIMUM PANEL WIDTH FOR LIVE LOAD OF 50 PLF4 Eq. 4 -Maximum Panel Width M al for 1/2-inch Monolithic Glass1•2 B = SO Eq. 5 -Maximum Panel Width M al for 5/8-inch Monolithic Glass1•3 B = 87.5 SI: 1 inch = 25.4mm; 1 ft= 305mm; 1 lb= 4.45N; 1. Mar= Mounting Option Allowable Moment Strength from ~ (In-lb) B = overall width of glass panel in inches 2. For 1/2-inch thick glass: 2.50 feet s B s 6.00 feet : Panel height is limited to a maximum of 23-inches (58.4 cm) for 1/2-inch (12.7 mm) thick monolithic glass. 3. For 5/8-inch thick glass: 2.50 feet s B s 5.00 feet : Panel height Is limited to a maximum of 41 -inches (104.1 cm) for 5/8-inch (15.5 mm) thick monolithic glass when the system must act as a guard. 4. Equations are limited to use with monolithic glass panels. Use of laminated glass panels in areas requiring consideration of a 50plf live load is outside of the scope of this report. ESR-3563 Page 11 of 31 ----------------1[~.P'i-J Uoat\V,dc1yA:ccp1cdandTru~1Ct1 !---------------"------- 8 B H RHS Hand Rail 112' Tempered Glass Om-.en,,cno & Tolerono .. (n>eln< (SI] • H 12 ~ ,rn tom&> per '"M load Tab!• 2 "i:SR b 10mm(•2 -OmmJ (314mll(•1116" -01] c: 3L m.tllffll.lffl to 42 ~ rM.11-,,um ~ve vrat-. "9 u,ihce d• S.. ,..-' L5.2 of ESR B ,., Tablt 2 m ESR 2/38 -Glass Vice"' Base Clamps Centered at m1dwidth- of each :•~ m, I 2/3B RHS Handrail 100mm 7 (lJf} ' -~,---------~---~-----------, I I ' ' '+' I I I I I I Section 8 0415mm R,vot t 11 316SS B 0 .. 2/3B 40mm t 11fi 11 25.4 mm (11 _j_ Ex2 / Plastic Gasket ( I00x40) one 3mm & 1mm 03te Juty 2014 W'IIIW.gb.CO\i U com Sc::a,iit· Sealo-1.1,"to Phone -+64 9 -41" 6..'-6S Glass Vice System for 1/2" Tempered Glass lnloCllf ... vi<e com US0 1 FIGURE 1 ESR-3563 Page 12 of 31 ----------------1[~!113'1 Ucsr l\'1ac•yMccp1cdaMTnmcd !--------------=----- 8 H RHS Hand Rall O.men«OnS & Tolemnctt rmetnc 1s111 ~ 12 nch6 "'" to ma., p,1 w-.nd load Tab:. 2 "' ESR b 20mm(•2 -Orm>) l314 lr.cl>(•1l16", -0)) c 3'.m1ntl'\umioA2...chumomJm d Sum,.onl.H2ofESR B su Ttbie 2 .. esR 2138 8 518" Tempered Glass -Glass Vice<!< Base Clamps Centered at midwrdth I m ·~::'" •• I RHS Handrail 100mm B d ., 2138 I I I I '+' I I 11~11:r i i Section B r 15mm 0415mm R1vot 316SS 01A'IV11 !j\1 Ex2 / Plastic Gasket ( I00x40) one 3mm& Imm Oat~. Jlif 201◄ SC&Je Sc.,le 1 I Ml Glass Vice System for 5/8" Tempered Glass FIGURE 2 www.~e.com Pncnt -64 9 414 656S _,to@g!Oi14"1Ce com US01 .,, i5 C ;:o m "' .J1,-- @~ ,: 0 ?;o ~ C: :le z 5' ~ :E " Ir ~2 I SE FOR POOi~ FENCE FALL PROTECTION NOT REQUIRED n , I 6'-6 3/4' MAXIMUM 2'-6" MINIMUM 25 mm f 2000 mm maximum GI.ASS Cl.AMPS 0A HAIIORAIL AT -a• ABOVE WALKING SURFACE [ l n n f 25 mm I J I I _fl_ ·-.. -2~rnm) Ancl!ora9e per app,qrete de1al .. I, II: 1/6 'l,1Dn-t "I 2/3WIDTH I, I, "I .., 116 WIDTH For installations with handrails requiring consideration of a 50plf load, panel width shall be limited to the widths outlined in Table 5. 0»11 ,,..,.....,..:,1u .. ~ -•a-.~~•,;ii,-\c...t'"l""-1 ~.,..w.,.~..c..J _,.. ..... ~°' ,....,..~_._,,." ft~...-S_!_~ -..u •L~ffl411'"ftlr'9'll'W •\ ..... t•.t~~ t'"-'"'11Wd~~ I Glass Vice Direct Fix Bracket .......-Frameless 16mm (5/8") FULLY-TEMPERED ~•· June201S Sc•lo SQlo 12li ~0:Jde. n Ai4,M....,., .... ~ www.gla••~.com "'"'""-··••<156~ ,nfn@glas.s'-"Ce com OF-A ;: ~ ! ~ )> I i 1 [ [ m u, :;o ' C,,,J c.n O'> C,,,J ,, I» cc (D ..... C,,,J 0 -C,,,J ..... ESR-3563 Page 14 of 31 ---------------l(~tt!;E.J Ucar W1dc•y11cccp1cdondTru~1cd , ____________ __;:::....... ___ _ 23/8 3 27/64 5/8 Glass Vice Clamp Concrete Deck ~- 10M SS threaded rods inserted 4" into 15/32" to 25/32" diam x 4-1 /4" deep holes and anchored with Hilti HIT-RE 500-V3 Glass Vice (option 1 a) Direct Fix -Fixing Detail Minimum Embedment -Cracked Concrete Tile > 5 1/4" minimum concrete depth f'c ~ 2,500 psi cracked condition Anchor Strength: <l>Mn = 3,466 in-lb Ma = 2,166 in-lb Oate: Mar 2020 Scale 1 :5 AU a,men5,ons an Inches www.glassvice.com Phone (760) 740-2338 usainfo@glassvlce.com FIGURE 4 _E_S_R_-3_5_6_3 ___________ , [dil*I /AOQI IV.do'yl.:ccprcd il!ld r,u~lcd I------------P_a..;;g;..e_1_5_o_f_3_1_ r- 3 27/64 5/8 Glass Vice Clamp Concrete Deck 1 OM SS threaded rods inserted 4" Tile ,,. 5 1/4" minimum concrete depth into 15/32" to 25/32" diam x 4-1 /4" deep holes and anchored with Hilti HIT-RE 500-V3 Glass Vice ( option 1 b) Direct Fix -Fixing Detail Minimum Embedment -Uncracked Concrete re 2: 2,soo psi uncracked condition Anchor Strength: <!>Mn = 4,741 in-lb M8 = 2,963 in-lb Date: Mar 2020 Scale 1:5 A• aimer,~ In .ncnes www glassvlce.com Phone (760) 740-2338 usainfo@glassvice.com FIGURE 5 _E_S_R_-3_5_6_3 __________ ,[Bili'I Uoal w,oc•yA!ccp1cd;)fldTru11cd I------------P_a..;;g;..e_1_6_o_f_3_1 ~ 2 3/8 3 27/64 5/8 / Glass Vice Clamp Concrete Deck I 1 OM SS threaded rods inserted 5" into 15/32" to 25/32" diam x 5-1/4" deep holes and anchored with Hilti HIT-RE 500-V3 Glass Vice (option 1 c) Direct Fix -Fixing Detail Standard Embedment -Uncracked Concrete Tile j 6 1/4" minimum concrete depth f'c i? 2,500 psi cracked condition Anchor Strength: <l>Mn = 7,498 in-lb Ma = 4,686 in-lb Date: Mar 2020 Scale 1:5 An aimensicm in lnct'M!s www.glassv1ce.com Phone (760) 740-2336 usainfo@glassvice.com FIGURE 6 ESR-3563 Page 17 of 31 --------------1[~13-1 /AOCIIVIOC1y Aeccp1cdil11dTMlcd 1-------------=----- ,._ co "' 2 3/8 3 27/64 5/8 Glass Vice Clamp Concrete Deck Tile t 1 OM SS threaded rods inserted 5" 6 1/4" minimum concrete depth into 15/32" to 25/32" diam x 5-1/4" deep holes and anchored with Hilti HIT-RE 500-V3 Glass Vice ( option 1 d) Direct Fix -Fixing Detail Standard Embedment -Uncracked Concrete fc l!: 2,500 psi uncracked condition Anchor Strength: <!>Mn = 7,498 in-lb Ma = 4,686 in-lb Date: Mar 2020 Scale 1 :5 A.ld~Jrlk\d'lo1 www.glassvice.com Phone (760) 740-2338 usalnfo@glassvlce.com FIGURE 7 ESR-3563 Page 18 of 31 --------------1[~13'11Aoc1w,oc•y1.:ccp1CdondTrvs1Cd !------------..;;;.. ___ _ I HIT-RE 100 co i?i ..- 3 1/8 D 3 27/64 5/8 Glass Vice Clamp r-- Concrete Tile > 8 1/2" minimum concrete depth 10M SS threaded rods inserted 7-1/4" into 15/32" to 25/32" diam x 7-1/2" deep holes and anchored with Hilti HIT-RE 500-V3 Glass Vice ( option 1 e) Direct Fix -Fixing Detail Standard Embedment -Uncracked/Cracked Concrete fc ~ 2,50 0 psi cracked or un cracked condition Anchor Strength: ¢Mn = 11,043 in-lb M0 = 6,902 in-lb Date: Mar 2020 Scale 1:5 Al O•mtnliont lf'I tne.nf9 www.glassvice.com Phone (760) 740-2338 usalnfo@glassvice.com FIGURE 8 ESR-3563 Page 19 of 31 --------------l[~tJS'J-1 IA0~11V,dr:'yt.:e<>p1cdllfldTru~1cd , ___________ .....;::;..._ ___ _ (X) -~ " N 3 27/64 5/8 ;, > 1/ / ~ f f /, / ~ ~ / / 1/ /j ,I/ // > Beam Glass Vice Clamp Adaptor Base Plate Timber Decking (4) M10x140 (5.5"Iong) lag screws into primary member 1-1/4" minimum hole edge distance Anchorage Strength Ma = 4,569 in-lb Glass Vice (Option 2) Date: Mar 2020 Scale 1 :5 Al cwntnMOnl w, tnchl.t www.glassvice.com Phone (760) 740-2338 usainfo@glassvice com Adaptor Base Plate Detail Decking Over Wood Framing -Lag Screws FIGURE 9 ESR-3563 Page 20 of 31 --------------l!~!:P'i-1 'ICGIIV"1c'yA:«,pted:lfldTMICd l-----------.....a"------- 3 27/64 5/8 /✓ ?' f ~ f .... ,..__ ~ /. 1/'// / / ~ ..... c.o 10mm x 25mm dia. (3/8" x 1 ") standoff // / :, f f' ~ / / // ,'J CX) i?i .... tO --C'") ~ C'") ..... ,..__ 8 3/4 MIN CONCRETE WIDTH 1 OM SS threaded rods inserted 7-1/2" into 15/32" to 25/32" diam X 7-3/4" deep holes and anchored with Hilti HIT-RE 500-V3 Option 3Aa Cracked cone. w/ 1-3/4" min edge dist 3Ab Cracked cone. w/ 2-3/16" min edge dist 3Ac Uncracked cone. w/ 1-3/4" min edge dist Anchorage Strength: Mn= 7,891 in-lb Ma = 4,932 in-lb Mn= 8,674 in-lb Ma = 5,421 in-lb Mn= 7,891 in-lb Ma = 4,932 in-lb Glass Vice ( option 3A) Date: Mar 2020 Scale 1:5 www.glassvice.com Phone (760) 740-2338 usalnlo@glassvice.com Architectural Bracket Fixing Detail Bracket Detail -Concrete FIGURE 10 ESR-3563 Page 21 of 31 --------------1[~13-1 Uostll',OC'yl.:copted(lfldTMICd 1-----------....;:;._ ___ _ 3 27/64 5/8 / 1/ 1/ ?'.,. Glass vice clamp f /. , Jack Screw 1/ 1/' ~ ,._,f ~ •• '.,,:· I.() Timber decking 1-3/8" max thickness r./1/ // 11/ -: ., C'5 ,, , ~ ..- c.o v co --.... N co ;::::: v 3"X3/8"X5.25" flat 'bar ~ standoff M 10 X length as req'd J t r. W 3"X3/16"X5.25" flat bar 316 S/S washer 316 S/S bolt MIN. DOUBLE 2X8 OR LARGER BEAM Mc ANY ANY SPECIES Glass Vice (option 38) Architectural Bracket -Fixing Detail Timber Deck Bolts Anchorage strength: Ma= 10,450 in-lb Al dtrnon~ hi ln«;noa Date: Mar 2020 www.glassvice.com Scale 1 :5 Phone (760) 740-2338 usainfo@glassvlce.com FIGURE 11 _E_S_R_-3_5_6_3 ________ ,[3:ailii /l oct IV1dc'1!.:ecp1cd.J11d lnmcd I---------P_a..,;;;g;...e_2_2_o_f_3_1 3 27/64 ~ // / / Glass Vice Clamp f !12 ... f ,._ ~ / ,:/// ~ :✓ f 1 f, Jacked Screw ,I I // ,f' I nntl n,,....t H '\\\', \ Spec,<Od fmoec•nJ for W00<l ,,.., Md mOlltu,e content (Mc . ... Timber decking Max 1-3/8" thick under clamp ✓ 3"X3/8"X5.25" flat bar standoff Framing 10 mm SS Lag Screws Length as required for specifed embedment 3Ca 5.209" Embedment for (DFL/SP/SCL) 3Cb 5. 76" Embedment for Hem-Fir 3Cc 3.65" Embedment for (DFL/SP/SCL) 3Cd 4.03" Embedment for Hem-Fir Any MC Any MC MC s 19% MC s 19% Ma= 4,569 in-lb Ma= 4,569 in-lb Ma = 4 ,569 in-lb Ma= 4,569 in-lb Glass Vice ( option 3C) Date: Mar 2020 Scale 1 :5 M CMl'lll'lJ,OOI in lnCtl,tS www.glassvlce.com Phone (760) 740-2338 usainfo@glassvlce.com Architectural Bracket Fixing Detail Timber Deck -Lag Screws FIGURE 12 ESR-3563 Page 23 of 31 ------------ll~!3'J tAoS11V1dc'1A:ccp1cdondTfu~1cd !------------------ 10mm dia S/S threaded rod with washers and nuts snug tight lengths as required 3 27/64 5/8 -. ' Glass Vice Clamp Concrete Deck Topping Slab Optional tile or other finish Steel Framing Hot rolled or cold formed Anchorage strength: ct>Mn = 14,390 in-lb Ma = 8,994 in-lb Glass Vice ( option 4) Date: Mar 2020 Scale 1 :5 Al auntnSiOns In tr'(:NI www.glassvlce.com Phone (760) 7 40-2338 usainfo@glassvice.com Direct Fix -Fixing Detail Concrete On Steel Framing FIGURE 13 ESR-3563 Page 24 of 31 -------------l[to;3-1 1ha!l\'1dC1y/.e«p1cdoMTMlcd 1------------=----- 3 27/64 5/8 ::, Glass Vice Clamp 1/ 1/ f f ~ f / N ~ 1/ /1/ Decking Any Material .,.... M10 SS bolt with nut and washer snug tight length as required ' .... Steel Framing i ·-is :g • >, ~ Threaded rods screwed into vice. Slide on the S-Bracket and lock into place with 1/2 Oam) nuts Hot rolled or cold formed Glass Vice ( option 5) S Bracket Fixing Detail Decking On Steel Framing Anchorage strength: <l>Mn = 14,390 in-lb Ma = 8,994 in-lb Date: Mar 2020 Scale 1:5 Mcknen.o'll~ine:htt www.glassvlce.com Phone(760)740-2338 usalnfo@glassvice.com FIGURE 14 ESR-3563 Page 25 of 31 --------------1l~[~l.:!Pa.:S$:J'IL.'.'~Ao:'.~1~11',o~cz.•1~M~cc~p1cd~an'.:'..d~T1u~s•~cd !----------------- ~ ..... ,-.. co cv5 <D 1" Diameter spacer or standoff 3 27/64 5/8 ...i ~ ..... N l() 10mm 316 Stainless steel bolts or studs length as required nut to either side of beam thickness as required Metal framing: Steel, Stainless Steel, Aluminum or alloy metal Hot rolled, Cold formed, built-up or extruded Glass Vice ( option 6) Architectural Bracket Fixing Detail Bracket Detail -Steel Anchorage strength: ct>Mn = 17,672 in-lb Ma = 11 ,045 in-lb Date: Mar 2020 Scale 1:5 Al dlfOtn~ In inc.nu www.glassvice.com Phone (760) 7 40-2338 usainfo@glassvlce.com FIGURE 15 ESR-3563 Page 26 of 31 --------------l[t{tts3'J Mc~tlV,dc'yt,xrp1cdant1TMlcd !--------------------- co --..... ...... ' SIS M 1 0 hex nut / 1"OD 10mm x25mm dla StS 1hreaded slandoff ni,1 Cladding 3 27/64" \l ;' Le rn,,,IIIT'f~"Mrll / (r ,.c U .Pf M'lD POlnl) Glass Vice® clamp Plas1lc shims as per Install manual W aterproof mombrane F.F.L. -' ... '~ ,;:; Deck Joist M10 S/S hanger lag screw must penetrate specified length into the rim joists/beam (excl. tapered tip.) Cavily May be filled with rigid Insulation or wood shim ...__ __ 1• OD min. melal or wood spacer ~---Sealant MS Silicone 3Oa 3.50" Embedment for (DFL/SP/SCL) 3Ob 5.0" Embedment for (DFL/SP/SCL) 3Oc 4.39" Embedment for Hem-Fir and PT 3Dd 6.27" Embedment for Hem-Fir, and PT ,o,t l.,_rllPr"ll)l'tl'l• O • 1 p 'J'°'U~ I/ I It 'ff" o 1 ..,, I f.!f•t, t>' ,, __," ., •1'" tt ttc.,. l JJ\ ,, ,"-~ f "ir """ ,,.., Glass Vice® Option 3D Architectural Bracket Fixing Detail ---Sheel Cladding MC :s; 19% Any MC MCS19% Any MC Ma = 6,265 in-lb Ma = 6,265 in-lb Ma = 6,265 in-lb M8 ;;;; 6,265 in-lb Oalc, _..,..2020 www.gleuvlce.com Phone (760) 740-2338 usalnf<>Cglnavlce .com Settle Al ,.,d-CtUed CAO 8, ,1,;ad 0.:,1.1 FIGURE 16 ESR-3563 Page 27 of 31 ----------------1[~13-J /Ao~, w,0~1y1<accp1cdand r,u~rcd !--------------------- LJ u ., ::, '8 :t .. I ~ > VI "' ~ l ' ...J M 8 ;, <.) > r . (!) I t . ~ ~ ~ ~ :. ~ < !t <.) -.:, ~ : , .,. .-- j • ' .. I 0::: :; \ ... ' ~ t.' .... "C ~ " C ,. ,, r .., '! r: ~ :r fol . " t ., 'l .., ~ ' ~ ' f " c· ;;;-.::: .x ... t, ";;; ..., ~ "(/'I ti t. ~ C, s-0 -~ f r-C. C c~r • Ql ~ M.,. .. ◄ 1 . --:: t., ..... ~ ~ t-~ '1 t-: • t ., ' 1 .... --\' .. 1 s C" ~I-{ _w : -t _, r ~ -' ii 0 D u 1 I .. ' I ~ , ~-t r: CJ r,, ' • "' ~ e A l ; ~ . 1 , ...... -C B 0 a., 0 8f • . ~ -ra :< L : ::t ~ 0(/) •' -, C .: ..: r "t' ~ _; u 0 -C .c 0 ~ a l4 "' "' < ~o ~ 0 ~ .... (/'I FIGURE 17-HAN0RAIL TERMINATION BRACKET ESR-3563 Page 28 of 31 -----------------1Jl[~~~tpi,;j3i~:l~IA~o~t1~1~~•,a'.:c'y~A:;<~cc~p~rcd~.lll~d~T1u~~~rcd~j--------------.;;;,_----- 0 le-\\00<1 1$,0 W,"vd ~c.1t ~ l,1ng1h ac; nN'<1l,d for :ic1oQ IJIO On'!' (1'1'('01 lo {;\IU or Gonc-cte • 6 x 2 S,mp.~on StrC'nl)-" l ~ I ,, &ro 11 ' .,. "' ,,. "1"1~• r• .. r:-T"' . ' '"""' --.. ~"" 240 ' FIGURE 18-TERMINATION BRACKET WITHOUT HANDRAIL ..J I'"') g:.. u > (:) > ,, ; .,, .:. J ESR-3563 Page 29 of 31 -----------------l[~t:Jn-1 /AC~I \V,dc1y1,:ccp1Cda11dTMlcd 1-------------------- J, C • :; 't l: ·-, l .. z ... - ; ~ 0 0 .,.. \ i ' -:. -. ' ' "I <- J.1!:0 .. ,,. i:.. ,.. .... ~ ,, ' / -/ FIGURE 19-H-BRACKET ::, ::, N .. ., l I ..J ., , C"') 0 ,::> ii l) I 6 .. ,, .. ~ -i .. < ~ ~ -~ (.) f f ~ : \ , ; -... -'g •C .. • a: ~ ~ i , ., -C, :...; ~ ~ -r ., .• ... 0 ' ~; . ... \ ' ~ ICC fVAlUATION SERVICE" ICC-ES Evaluation Report ESR-3563 City of LA Supplement Reissued January 2025 This report is subject to renewal January 2026. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the lntemational Code Council® DIVISION: 05 00 00-METALS Section: 05 52 00-Metal Railings Section: 05 7313-Glazed Decorative Metal Railings DIVISION: 08 00 00-0PENINGS Section: 08 81 00-Glass Glazing Section: 08 88 00-Special Function Glazing REPORT HOLDER: GLASS VICE HOLDINGS USA LLC EVALUATION SUBJECT: GLASS VICE GLASS PANEL RAILING AND GLASS BALUSTER SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Glass Vice Glass Panel Railing and Glass Baluster Systems, described in ICC-ES evaluation report ESR-3563, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). Applicable code editions: ■ 2020 City of Los Angeles Building Code (LABC) ■ 2020 City of Los Angeles Residential Code (LARC) 2.0 CONCLUSIONS The Glass Vice Glass Panel Railing and Glass Baluster Systems, described in Sections 2.0 through 7 .0 of the evaluation report ESR-3563, comply with the LABC Chapter 24, and the LARC, and are subject to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Glass Vice Glass Panel Railing and Glass Baluster Systems described in this evaluation report supplement must comply with all of the following conditions: • All applicable sections in the evaluation report ESR-3563. • The design, Installation, conditions of use and identification of the Glass Vice Glass Panel Railing and Glass Baluster Systems are in accordance with the 2018 International Building Codell'J (IBC) provisions noted in the evaluation report ESR-3563. • The design, installation and Inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. • Under the LARC, an engineered design in accordance with LARC Section R301.1.3 must be submitted. This supplement expires concurrently with the evaluation report, reissued January 2025. ICC·ES Evalumlon Rrportr are ,wt w he cmnt111ed as represemlng ,,estln!liCl or any 01her uttrllmteJ not speciflcal(,• addressed, nor arc they to be ronJcnu!ll a~ an endors,ment of the subject of the Yf!/XJrt ur u Yf!COmni,ndation for Its r,s,, There I.• no warranty by ICC £1"U/11atlon Semce. llC, exp res, or lm11lied, as tu a11y fi,u/i11>: or Olht!T mum:r in thi,'t repon, ur u,· tu any p1y,c/11ct ,·ov~red by tltt' nqXJrt Copyright C 2025 ICC Evaluation Service, LLC. All rights reserved. Page 30 of 31 ~ ICC EVALUATION SERVICE" ICC-ES Evaluation Report www.lcc-es.org I (800) 423-6587 I (562) 699-0543 DIVISION: 05 00 00-METALS Section: 05 52 00-Metal Ralllngs Section: 05 731~Iazed Decorative Metal Railings DIVISION: 08 00 OO--OPENINGS Section: 08 81 00-Glass Glazing Section: 08 88 00-Speclal Function Glazing REPORT HOLDER: GLASS VICE HOLDINGS USA LLC EVALUATION SUBJECT: ESR-3563 FL Supplement Reissued January 2025 This report is subject to renewal January 2026. A Subsidiary of the International Code Council® GLASS VICE GLASS PANEL RAILING AND GLASS BALUSTER SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Glass Vice Glass Panel Railing and Glass Baluster Systems, described in ICC-ES evaluation report ESR-3563, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2020 and 2023 Florida Building Code-Building ■ 2020 and 2023 Florida Building Code-Residential 2.0 CONCLUSIONS The Glass Vice Glass Panel Railing and Glass Baluster Systems, described in Sections 2.0 through 7.0 of ICC-ES evaluation report ESR-3563, comply with the 2020 and 2023 Florida Building Code-Building and the 2020 and 2023 Florida Building Code-Residential. The design requirements must be determined in accordance with the Florida Building Code-Building or the Florida Building Code-Residential, as applicable. The installation requirements noted in ICC-ES evaluation report ESR-3563 for the 2018 and 2021 International Bui/ding Code® meet the requirements of the Florida Building Code-Building or the Florida Building Code-Residential, as applicable. Use of the Glass Vice Glass Panel Railing and Glass Baluster Systems has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code-Building or the Florida Building Code-Residential wtth the following conditions: 1. The system must be installed without a top rail or handrail at a total height of less than or equal to 42 inches ( 106. 7 cm) with 9/16-inch thick (14.3 mm) or 5/8-inch thick (15.87 mm) laminated tempered glass panels up to 41 inches (104.1 cm) in height with an interlayer meeting the requirements of Section 3.2.1 of ESR-3563. 2. The system must be limited to installations in one and two family dwellings under the Florida Building Code-Building the where the 50 plf (0.73 kN/m) live load is not applicable or the Florida Building Code-Residential. For products falling under Florida Rule 61G20-3, verification that the report holder's quality assurance program Is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted Is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued January 2025. ICC·ES Evalumiun R'1porls are not to he t·m,,,,ruecl Uf repreJenllttg a~sthetics or any oth(•r at1rih11tes nut spedfical(v addressed. nor are lhi!J· to hv cunJtrovd ~ ~ u.r an ~ndorsemcmr ofrhe subject ,,flhP repo11 or a recummendali(.)fl/or irj Jiff'. Thetl! is nn lt.'urranf)• hy ICC En1/11a,ion Se,,•lre, LLC. (!).p1•e5s or Imp/le(/, as ~- r, I h I d lb h ••• :--·. to any me, iug or 01 ,1r mauer In t u:f n!ptJrt, ur u.r lo any /Jl'U U<'l cu,·,•re, _V t <' report, Copyright Q 2025 ICC Evaluation Service, LLC. All rights reserved. Page 31 of 31 True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T | 562.733.8030 October 8, 2025 City of Carlsbad City of Carlsbad – FINAL REVIEW Community Development Department - Building Division City Permit No: CBR2025-1999 1635 Faraday Ave. True North No.: 25-018-849 Carlsbad, CA 92008 Plan Review: Balcony Remodel Address: 111 Sequoia Ave Unit G, Carlsbad CA Applicant Name: Martin Gordon Applicant Email: martin.scott.gordon@gmail.com OCCUPANCY AND BUILDING SUMMARY: Occupancy Groups: R2 Occupant Load: N/A Type of Construction: VB Sprinklers: No Stories: 3 Area of Work (sq. ft.): 213 sq. ft. The plans have been reviewed for coordination with the permit application. Valuation: Confirmed Scope of Work: Confirmed Floor Area: Confirmed Attn: Building & Safety Department, True North Compliance Services, Inc. has completed the final review of the following documents for the project referenced above on behalf of the City of Carlsbad: 1. Drawings: Electronic copy dated September 29, 2025, by M. McKenny 2. Other Documents: Electronic copy of ESR-3536 The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review. Please note that our review has been completed and we have no further comments. We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Ed Dion - Plan Review Engineer .JTrue North ~ COMPLI ANCE SERV ICES True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T | 562.733.8030 August 25, 2025 City of Carlsbad City of Carlsbad– FIRST REVIEW Community Development Department - Building Division City Permit No: CBR2025-1999 1635 Faraday Ave. True North No.: 25-018-849 Carlsbad, CA 92008 Plan Review: Balcony Remodel Address: 111 Sequoia Ave Unit G, Carlsbad CA Applicant Name: Martin Gordon Applicant Email: martin.scott.gordon@gmail.com True North Compliance Services, Inc. has completed the review of the following documents for the project referenced above on behalf of the City of Carlsbad. Our comments can be found on the attached list. 1. Drawings: Electronic copy dated June 6, 2024, by M. McKenny. 2. Other Documents: Electronic copy of Permit Application Attn: Permit Technician, the scope of work on the plans has been reviewed for coordination with the scope of work on the permit application. See below for information if the scope of work on plans differs from the permit application: Valuation: See Notes Below Scope of Work: Confirmed Floor Area: Confirmed Notes: no valuation given Our comments follow on the attached list. Please call if you have any questions or if we can be of further assistance. Sincerely, True North Compliance Services Review By: Ed Dion - Plan Review Engineer .JTrue North ~ COMPLI ANCE SERV ICES Balcony Remodel City of Carlsbad– FIRST REVIEW 111 Sequoia Ave Unit G City Permit No.: CBR2025-1999 August 25, 2025 True North No.: 25-018-849 Page 2 Plan Review Comments ELECTRONIC - RESUBMITTAL INSTRUCTIONS: Please do not resubmit plans until all departments have completed their reviews. For status, please contact building@carlsbadca.gov Please make all corrections, as requested in the correction list. Corrected sets can be submitted as follows: • Email the revised plans and comment response letter(s) to building@carlsbadca.gov for continued review. o Note: If this project requires FIRE PREVENTION review, ensure that you follow their specific instructions for resubmittal review. The city will not route plans back to Dennis Grubb & Associates for continued Fire Prevention review. GENERAL INFORMATION: A. The following comments are referred to the 2022 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California). B. There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. C. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re-check. D. Where applicable, be sure to include the architect and engineer’s stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This item will be verified prior to plan approval. E. If you have any questions regarding the comments below, please contact Ed Dion via email edion@tncservices.com or telephone (562) 733-8030. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: R2 Occupant Load: N/A Type of Construction: VB Sprinklers: No Stories: 3 Area of Work (sq. ft.): 213 sq. ft. ARCHITECTURAL COMMENTS: A1. Revise occupancy to R2 per CBC Chapter 3 Balcony Remodel City of Carlsbad– FIRST REVIEW 111 Sequoia Ave Unit G City Permit No.: CBR2025-1999 August 25, 2025 True North No.: 25-018-849 Page 3 A2. Per city policy, specify the roofing material to have a Class A fire classification. A3. Licensed Architect to stamp and sign all plan sheets. (Business & Professions Code Sections 5537, 5538, and 6737.1) A4. The following comments apply to the balcony: a) Provide transition detail from the exterior wall to the balcony floor. CBC 1403.2. b) Provide a floor assembly for the balcony floor system. CBC 1406.3. c) Provide ventilation to the to enclosing framing in the balcony. Openings shall provide a net free cross ventilation and not less than 1/150 of the area of each space. CBC 2304.12.2.6 ACCESSIBILITY COMMENTS: No Comments MECHANICAL COMMENTS: No Comments ELECTRICAL COMMENTS: No Comments PLUMBING COMMENTS: No Comments GREEN BUILDING COMMENTS: No Comments ENERGY COMPLIANCE COMMENTS: T1. Note 0.30 Max U factor and 0.23 Max SHGC for the new sliding glass door per CEnC table 180.2-B STRUCTURAL COMMENTS:GUARD General: S1. Provide guard attachment detail and calculations capable of resisting a 200 pound load at the top per CBC 1607.8.1. If you have any questions regarding the above comments, please contact Ed Dion via email edion@tncservices.com or telephone (562) 733-8030. [END]