Loading...
HomeMy WebLinkAbout6183 PASEO DEL NORTE; 200; AS000016; Permit10/31/25, 7:32AM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: about:blank Fees($) 416.5 AS000016 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS000016 6183 PASEO DEL Status: NORTE SPRINK Applied 2110401800 Approved: 0 Issued: Inspector: EYE LASER CENTER #200 Owner: Add'I Fees ($) 0 Total($) 416.5 ISSUED 2/16/2000 Balance($) 0 1/1 Carlsbad Fire Department 990460 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Auto. Sprinkler, OH Reviewed by: Date of Report: 0211812000 ------------ Name: Lifeguard Fire Prot Address: 2613 Temple Heights Dr Ste B City, State: Oceanside CA 92056 Plan Checker: Job #: 990460 . Job Name: Eye Laser Center Bldg #: CB994394 ------------------Job Address: 6183 Paseo Del Norte Ste. or Bldg. No. 200 [8l Approved D Approved Subject to D Incomplete Review FD Job# ------ The item you have submitted for review has been approved. The approval is based on plans, information and/ or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office lo insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 990460 2nd FD File# 3rd Other Agency ID PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS UNIVERSAL MODEL A QUICK RESPONSE, 3mm BULB TYPE, 1/2" (15mm) ORIFICE, 1/2" NPT** WRENCH FLAT * 2-3/16" l5~.6mm) 112· 3 SSP DEFLECTOR* PENDENT MODEL F700orF705 RECESSED ESCUTCHEON ** t NPT ~----2-7/8" (73,0mm) DIA. --ol 7/16"(11,lmml MAKE-IN RECESSED PENDENT UPRIGHT CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7 /1 can be provided on special request 1 -Frame 2 • Button 3 -Gasketed Spring Plate 4 • Bulb 5 -Compression Screw 6 • Deflector FIGURE A 1/2 INCH ORIFICE MODEL A QUICK RESPONSE PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS , GENERAL DESCRIPTION The 1/2 inch (15mm) orifice Universal Model A Quick Response Pendent, Recessed Pendent, and Upright Sprin- klers (Rel. Figure A) are automatic sprinklers of the frangible bulb type. They are "quick response -standard orifice spray sprinklers" 'intended tor use in lire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble Listing or Approval agency (e.g., UL Listing is based on NFPA 13 re- quirements). The Pendent, Recessed Pendent, and Upright Sprinklers all produce a hemispherical water distri- bution pattern below the deflector. The recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- nation with either the Model F700 or F705 Recessed Escutcheon (Ref. Fig- ures A and C). The Recessed Escutch- eons have a separable two-piece de- sign which allows installation of the sprinklers and pressure testing of the fire protection system, prior to ceiling construction and/or application of a fin- ish coat to the ceiling. They also permit refinishing of a ceiling surface without Printed in U.S.A. 11-98 having to first shut down the fire pro- tection system and remove the sprin- klers. The vertical adjustment provided by the Recessed Escutcheons substan- tially reduces the accuracy to which the length of fixed pipe drops to the sprinklers must be cut. Also, the Clo- sure has a 1/2 inch (12,7mm) wide flange which provides ample clear- ance for covering the mounting hole. APPROVALS AND STANDARDS Laboratory listings and approvals tor the 1/2 inch (15mm) orifice Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers are given in Table A. WARNING The 112 inch orifice Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having juris- diction. Failure to do so may impair the integrity oflhese devices. The owner is respo!',sible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should be contacted relative fo any questions. Installation of Model A Pendent Sprinklers in recessed escutcheons other than the F700 or F705 will void all sprinkler warranties, as wetl as possibly void the sprinkler's Approv- als and I or Listings. TECHNICAL DATA The 1/2 inch (15mm) orifice Model A Quick Response Pendent, Recessed Pendent, and Upright Sprinklers are rated tor use at a maximum service pressure of 175 psi (12, 1 bar) and they are available in the temperature rat- ings and finishes indicated in Table A. Recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- TD51 SM SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL CHROME POLYESTER RATING LIQUID BRASS PLATED COATED COLOR (All Colors) 135'F/57'C Orange PENDENT 155'F/68'C Red and 175'F/79'C Yellow 1,2,3,4,5,6 UPRIGHT 200'F/93'C Green 286'F/141 'C Blue RECESSED 135'F/57'C Orange PENDENT 155'F/68'C Red with F700 1,2,5,6, 7 RECESSED 175'F/79'C Yellow ESCUTCHEON 200'F/93'C Green RECESSED 135'F/57'C Orange PENDENT with 155'F/68'C Red F705 1,2,3,5,6, 7 1,2,5,6, 7 RECESSED 175'F/79'C Yellow ESCUTCHEON 200'F/93'C Green NOTES: 1.Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers. 2.Listed by Underwriters' Laboratories of Canada as Quick Response Sprinklers. 3.Approved by Factory Mutual Research Corporation as Quick Response Sprinklers for use in Light or Ordinary Hazard (Groups 1 and 2) Occupancies.The FM Approvals are for wet sprinkler systems only and exclude occupancies involvlng low flash point (less than 100"F/38'C) flammable liquids or flammable hydraulic liquids. 4.Approved by the Loss Prevention Council (United Kingdom) as Quick Response Sprinklers. 5.Approved by the Scientific Services Laboratory (Australia} as Quick Response Sprinklers. 6.Accepted by the City of New York under MEA 241-94-E. 7 .Approved by the Loss Prevention Council (United Kingdom). The LPC does not rate the sensitivity of recessed sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS nation with either the Model F700 or F705 Recessed Escutcheon. The Re- cessed Escutcheons are available with a chrome plated finish or a coated finish in any color. The nominal discharge curve plotted in Figure B represents the flow "Q" in GPM (LPM) as determined by the fol- lowing formula: where the nominal discharge coeffi- cient "K" equals 5.6 (80, 7); and, "p" equals the residual flowing pressure in psi (bar). Listing standards permit the actual value of "K" to vary from 5.3 to 5.8 (76,4 to 83,6); however, for hy- draulic calculations, a K-factor of 5.6 (80, 7) is to be applied. The Frame of the Model A Sprinkler (Ref. Figure A), is bronze per ASTM B176 (C87800) or, a proprietary alloy designated QM. The Button (bulb re- tainer) is phospher bronze per ASTM B103 (C51000 or C52100). The Gas- keted Spring Plate consists of a Berylium Nickel (N03360) disc spring that is sealed on both its inside and outside faces with a Teflont gasket. The Compression Screw is bronze per ASTM B140 (C31400) and the Deflec- tor is brass per ASTM B152 (C11000). The Model A Sprinklers utilize a 3mm diameter frangible bulb: Table A indi- cates the bulb liquid color as a function of temperature rating. The F700 and F705 Recessed Es- cutcheons provided for use with the Model A Pendent Sprinkler (Ref. Fig- ure C) have a Closure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it, maintain a tight friction fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and compensate for minor non-perpendicularity between the Model A Sprinkler and the ceiling. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bub- ble should be present. The diameter of the air bubble is approximately I I 16 inch (1,6mm) for the 135'F/57'C to 3 I 32 inch (2,4mm) for the 286'F I 141'C rating. (At higher ambi- ent temperatures, the bubble may be barely perceptable for the lower tem- perature ratings.) Installation of Model A Pendent Sprinklers in recessed escutcheons DIICHAIIGt: IN U.I. GALLONI PHI IIIJIUTE fQPII) 1011HH3035 .. t" IIAflTIAl CUIIYt: ONLY ,., ; .. ....... "" IHU1111H"I 5 .. ,,, , • z • • ... .. . • . r • • , ! H m 2" 1,1 I! • • • in ,., ~ f 10 f'AIITIAL CUii YI! ONLY IIAI. PIIESIUlll 11,1 IAR , .. ,0 H ,oo 111 110 OIBCMAl'IGll IN LITlll!S Pllll MINUTE FIGURE B NOMINAL DISCHARGE CURVE other than the F700 or F705 will void all sprinkler warranties, as well as possibly void the sprinkler's Approv- als and I or Listings. The Model A Sprinklers must be in- stalled in accordance with the follow- ing instructions. 1. Prior to installing pendent sprinklers and if applicable, verify that the face of the sprinkler fitting is within the proper range of distance which can be accommodated by the type of escutcheon being used. t DuPont Registered Trademark MODEL F700 FULLY RECESSED DIMENSIONSt Up to 1/2 inch adjustment from minimum 1/4 Inch to maximum 3/4 Inch recessed position. Dim. Inches MM A-5/8 1/8tt 15,9 3,2 8-Min. 3/4 19,1 8-Nom. 1 25,4 B-Max. 1-1/4 31,8 C-Mln. 1/4 6,4 C-Max. 3/4 19,1 HIGH ADJUSTMENT DIMENSIONS Up to 3/4 Inch adjustment from the flush celling position to 3/4 Inch recessed position. Dim. Inches MM A-1/2 1/4tt 12,7 6,4 B-Min. 3/4 19, 1 B-Nom. 1-1/8 28,6 8-Max. 1-1/2 38, 1 C-Min. FLUSH - C-Max. 3/4 19, 1 MODELF705 FULLY RECESSED DIMENSIONSt Up to 1/4 Inch adjustment from minimum 1/4 Inch to maximum 1/2 Inch recessed position. Dim. A- B-Mln. B-Nom. B-Max. C-Mln. C-Max. Inches 1/2tt 1 1-1/8 1-1/4 1/4 1/2 HIGH ADJUSTMENT DIMENSIONS MM 12,7 25,4 28,6 31,8 6,4 12,7 Up to 1/2 Inch adjustment from the flush celling position to 1/2 Inch recessed position. Dim. Inches MM A-3/8 1/8tt 9,53,2 B-Min. 1 25,4 B-Nom. 1-1/4 31,8 B-Max. 1-1/2 38, 1 C-Min. FLUSH C-Max. 1/2 12,7 2-7/8" DIA. {73,0mm) FACE 2-1/4" DIA. OF FITTING t For best overall appearance. tt Remaining 1/4 inch (6,4mm) of adjustment can be used to compensate for variations in sprinkler make-in and fitting take-out. (57,2mm) 1-Model A Pendent Sprinkler 2-Model F700 or F705 Recessed Escutcheon a-Mounting Plate b-Closure FIGUREC MODEL A RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F700 OR F705 RECESSED ESCUTCHEON When installing a Model A Pendent Sprinkler with the either the F700 or F705 Recessed Escutcheon, for best overall appearance, use Di- mension "A" indicated under the "Fully Recessed Dimensions" head- ing of Flgure C. Otherwise, use Di- mension "A" under the "High Adjust- ment Dimensions" heading. In either case, the remaining adjustment can be used to compensate for the pos- sible manufacturing variations in take-out of the fiming, as well as in the make-in of the sprinklers (as per- mitted by ANSI B1.20.1 ). 2. With pipe thread sealant applied to the pipe threads and after installing the F700 or F705 Mounting Plate ( or other escutcheon, as applicable) over the sprinkler threads, hand tighten the sprinkler into the sprin- kler fitting. 3. Refer to Figure D and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. The F850 Sprinkler Wrench must be used for installing polyester coated sprinklers, in order to prevent dam- age to the sprinkler finish. NOTES A leak tight 112 inch NPT sprin- kler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19, 0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install the sprinklers. Higher lev- els of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to make-up for in- sufficient adjustment in the es- cutcheon plate by under· or over- tightening the sprinkler. Reac!Just the position of the sprinkler fitting to suit. 4. In recessed pendent sprinkler instal- lations, after the ceiling has been installed or the finish coat has been applied, slide on the F700 or F705 Closure over the Model A Sprinkler and push the Closure over the Mounting Plate until Its flange comes in contact with the ceiling. CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 1 00'F/38'C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com-