HomeMy WebLinkAboutSDP 2021-0016; CARLSBAD OAKS NORTH LOT 3; FINAL SOILS REPORT IMPROVEMENTS; 2025-08-29FINAL REPORT OF TESTING AND OBSERVATION SERVICES PERFORMED DURING IMPROVEMENT CONSTRUCTION CARLSBAD OAKS NORTH BUSINESS PARK - LOT 3 (DRAWING NO. 541-4A, PROJECT NO. SDP2021-0016) CARLSBAD, CALIFORNIA AUGUST 29, 2025 PROJECT NO. 06442-32-34B PREPARED FOR: 320 15 16 17 18 BI0-BASIN BI0-BASI N BI0-BASIN ENT R A N C E ENT R A N C E 4 4 8 COM P A C T 5 GRADE LEVEL OVERHEAD DOORS ENTRANCE ENTRANCE ENTRANCE GRA D E L E V E L O V E R H E A D D O O R S GRA D E L E V E L O V E R H E A D D O O R S ENTRANCE 4 6 6FT MAX RETG WALL 3 5 7 6 64 CO M P A C T 4 6FT M A X R E T G W A L L 8 8 COM P A C T COM P A C T 56 ENTRANCEENTRANCE WHIPTAIL LOOP PROPOSED BUILDING C PROPOSED BUILDING APROPOSED BUILDING B COMPACT 4 OPEN SPACE NEW TRANSFORMER FIRE RISER RM ELEC RM FIRE RISER RM FIRE RISER RM ELEC RM ELEC RM 15' - 6 3/4"15' - 6 3/4" ASSUMED IMAGINARY PROPERY LINE MAX 7 5 % U N P R O T E C T E D O P E N I N G S ( 7 0 5 . 8 ) MAX 7 5 % U N P R O T E C T E D O P E N I N G S ( 7 0 5 . 8 ) PROPOSED OCCUPANCIES: B, S1, F1FIRE SPRINKLEREDPROPOSED OCCUPANCIES: B, S1, F1FIRE SPRINKLEREDPROPOSED OCCUPANCIES: B, S1, F1FIRE SPRINKLERED CONC SCREEN WALL TRASH/RECYCLE ENCLOSURE TRASH/RECYCLE ENCLOSURE 6X8 CONC. PAD W/ (2) GALV. U-RACKS FOR (4) SHORT TERM BICYCLES CLOSE EXISTING D R I V E W A Y . NEW CURB, GUTTE R & S I D E W A L K P E R C I V I L . 6X6 CONC. PAD W/ (2) GALV. U-RACKS FOR (3) SHORT TERM BICYCLES CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH CLNAIRVEH EXISTING DRIVEWAY. TRASH/RECYCLE ENCLOSURE STANDARD4 R 28' - 0 " R 2 8 ' - 0 " R 94' - 0 " FIRE LANE FIRE LANE FIRE LANE FIR E L A N E FIR E L A N E 26' - 0" 26' - 0 " 26' - 0" 26' - 0 " R 2 8 ' - 0 " R 50' - 0 " 6X8 CONC. PAD W/ (2) GALV. U-RACKS FOR (4) SHORT TERM BICYCLES 48' - 0" 89' - 2 1 / 2 " 84' - 4 3 / 4 " 66' - 9 5 / 8 " 141' - 4 1/4" 84' - 1 7 / 8 " 78' - 3 " DE S DS 4" ON 6960 Flanders Drive ■ San Diego, California 92121-2974 ■ Telephone (858) 558-6900 ■ www.geoconinc.com Project No. 06442-32-34B August 29, 2025 Tech Contractors 3575 Kenyon Street San Diego, California 92110 Attention: Mr. Raul Guzman Subject: FINAL REPORT OF TESTING AND OBSERVATION SERVICES PERFORMED DURING IMPROVEMENT CONSTRUCTION CARLSBAD OAKS NORTH BUSINESS PARK – LOT 3 (DRAWING NO. 541-4A, PROJECT NO. SDP2021-0016) CARLSBAD, CALIFORNIA References: 1. Improvement Plans for: Lot 3, Whiptail Loop, Project No. SDP2021-0016, Drawing No. 541-4A, prepared by Spear & Associates, Inc., dated July 1, 2024. 2. Private Utility Plans for: Lot 3, Whiptail Loop, Project No. SDP2021-0016, prepared by Spear & Associates, Inc., dated August 19, 2024. 3. Fire Plans for: Lot 3, Whiptail Loop, Project No. SDP2021-0016, Drawing No. 541- 4A, prepared by Spear & Associates, Inc., dated August 26, 2024. 4. Grading Plans for: Lot 3 Whiptail Loop, Drawing No. 541-4A, Project No. SDP2021- 0016, Carlsbad, California, prepared by Spear & Associates, Inc., dated July 1, 2024. Dear Mr. Guzman: In accordance with your request, we provided compaction testing and observation services during construction of improvements at the subject project. We provided our services between August 2024 and August 2025. The scope of our services consisted of performing in-place density tests on a “call out” basis during minor grading and trench backfill of underground utilities (see Table I for specific utilities) and wall backfill. We also performed in-place density tests on curb/gutter subgrade, drive isle/parking lot subgrade, aggregate base and asphalt concrete pavement. Carlsbad Oaks North Business Park – Lot 3 Final Report of Testing and Observation Services Performed During Improvement Construction Project No. 06442-32-34B - 2 - August 29, 2025 We provided full-time testing and observation services during construction of Mechanically Stabilized Earth (MSE) retaining wall No. 1. Specific to MSE wall No. 1, our services consisted of observing the foundation excavation prior to placement of base rock and block layers, observing geogrid placement and observing installation of the wall drainage system. We understand that the wall drain will be connected to the project storm drain system by TFW Construction Incorporated, the project general contractor. Reinforcement of the wall consisted of Miragrid 3XT. We checked that the grid lengths were consistent with the project plans (Reference 4) during wall construction. Slack was removed from the grids by pulling the grid tight and either nailing the back of the grid down or placing soil on the back of the grid. Our observations indicated that the grids were placed in substantial conformance with the referenced plans. The wall drain system was constructed in general conformance with the project plans. The drain system placed behind the wall units consisted of a 4-inch-diameter, PVC perforated drainpipe encapsulated in ¾-inch gravel and wrapped in Mirafi 140N filter fabric. Minor grading consisted of constructing the portion of fill slope above the MSE wall that was removed as part of the wall back cut excavation. Soil fills were placed in lifts no thicker than would allow for adequate bonding and compaction. The soil was moisture conditioned, as necessary, and mixed during placement. We performed in-place density tests in general conformance with ASTM D 6938 for soil and aggregate base, and ASTM D2950 for asphalt concrete. Table I presents the in-place dry density and moisture content tests results. Where fill soil contained rock larger than ¾-inch, a correction was made to the laboratory maximum dry density and optimum moisture content using methods suggested by AASHTO T224. The values of maximum dry density and optimum moisture content presented on Table I reflect these corrections Results of in-place density tests indicate soil placed during minor grading, trench backfill, wall backfill, and curb/gutter subgrade possess a dry density of at least 90 percent of the laboratory maximum dry density near or slightly above optimum moisture content at the locations tested. Similarly, a relative compaction of at least 95 percent was achieved on the drive isle/parking lot subgrade soil, aggregate base and asphalt concrete. Carlsbad Oaks North Business Park – Lot 3 Final Report of Testing and Observation Services Performed During Improvement Construction Project No. 06442-32-34B - 3 - August 29, 2025 We performed laboratory compaction tests on representative soil samples in accordance with ASTM D 1557 (maximum dry density and optimum moisture content), D 4318 (Atterberg Limits), D 6913 (sieve analyses for soil) and AASHTO T-236 (shear strength characteristics). We also performed laboratory tests on asphalt concrete samples in accordance with ASTM D 2726 (Hveem density), D 2041 (theoretical maximum density), D 1560 (asphalt concrete stability), D 6307 (asphalt content), and C 136 (sieve analysis for asphalt). Tables II through VI present the laboratory test results. Figures 1 through 4 present the direct shear and sieve analyses laboratory test results. If there are questions regarding this report, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, GEOCON INCORPORATED Emilio Alvarado RCE 66915 EA:am Attachments: Figures 1 through 4 (e-mail) Addressee SAMPLE NO.: GEOLOGIC UNIT: SAMPLE DEPTH (FT): NATURAL/REMOLDED: 1 K 2 K 4 K AVERAGE 1053.8 2261.4 4657.4 -- 7.3 7.3 7.4 7.3 120.0 120.3 120.0 120.1 1 K 2 K 4 K AVERAGE 11.4 11.9 11.4 11.6 1256 2000 3623 -- 1014 1932 3517 -- 540 33 320 35 Figure 1 FRICTION ANGLE (DEGREES) NORMAL STRESS TEST LOAD ACTUAL NORMAL STRESS (PSF): WATER CONTENT (%): ULTIMATE RESULTS PEAK NORMAL STRESS TEST LOAD WATER CONTENT (%): PEAK SHEAR STRESS (PSF): 06442-32-34B CARLSBAD OAKS NORTH BUSINESS PARK - LOT 3 COHESION, C (PSF) FRICTION ANGLE (DEGREES) DIRECT SHEAR - AASHTO T-236 PROJECT NO.: COHESION, C (PSF) DRY DENSITY (PCF): AFTER TEST CONDITIONS 3 ULT.-E.O.T. SHEAR STRESS (PSF): INITIAL CONDITIONS R Qcf N/A 0 500 1000 1500 2000 2500 3000 3500 4000 0.000 0.050 0.100 0.150 0.200 0.250 0.300 SH E A R S T R E S S ( P S F ) HORIZONTAL DEFORMATION (IN) 1 K 2 K 4 K 1 K PEAK 2 K PEAK 4 K PEAK 1 K ULTIMATE 2 K ULTIMATE 4 K ULTIMATE 4 K 2 K 1 K 0 1000 2000 3000 4000 5000 6000 7000 0 1000 2000 3000 4000 5000 6000 SH E A R S T R E S S ( P S F ) NORMAL STRESS (PSF) SAMPLE NO.: GEOLOGIC UNIT: SAMPLE DEPTH (FT): NATURAL/REMOLDED: 1 K 2 K 4 K AVERAGE 1053.8 2261.4 4657.4 -- 6.6 6.9 6.6 6.7 124.1 123.7 124.1 124.0 1 K 2 K 4 K AVERAGE 10.4 10.9 10.8 10.7 995 1749 3217 -- 918 1749 3217 -- 350 32 270 32 Figure 2 COHESION, C (PSF) DRY DENSITY (PCF): AFTER TEST CONDITIONS 4 ULT.-E.O.T. SHEAR STRESS (PSF): INITIAL CONDITIONS R Qcf N/A 06442-32-34B CARLSBAD OAKS NORTH BUSINESS PARK - LOT 3 COHESION, C (PSF) FRICTION ANGLE (DEGREES) DIRECT SHEAR - AASHTO T-236 PROJECT NO.: FRICTION ANGLE (DEGREES) NORMAL STRESS TEST LOAD ACTUAL NORMAL STRESS (PSF): WATER CONTENT (%): ULTIMATE RESULTS PEAK NORMAL STRESS TEST LOAD WATER CONTENT (%): PEAK SHEAR STRESS (PSF): 0 500 1000 1500 2000 2500 3000 3500 0.000 0.050 0.100 0.150 0.200 0.250 0.300 SH E A R S T R E S S ( P S F ) HORIZONTAL DEFORMATION (IN) 1 K 2 K 4 K 1 K PEAK 2 K PEAK 4 K PEAK 1 K ULTIMATE 2 K ULTIMATE 4 K ULTIMATE 4 K 2 K 1 K 0 1000 2000 3000 4000 5000 6000 7000 0 1000 2000 3000 4000 5000 6000 SH E A R S T R E S S ( P S F ) NORMAL STRESS (PSF) Qcf D10 (mm)D30 (mm)D60 (mm) 0.047 0.274 1.080 CARLSBAD OAKS NORTH BUSINESS PARK - LOT 3 PROJECT NO.: U.S. STANDARD SIEVE SIZE 06442-32-34B SAMPLE NO.:3 GEOLOGIC UNIT: SAMPLE DEPTH (FT.):N/A Figure 3 Cc 1.5 TEST DATA SOIL DESCRIPTION SC - Clayey SAND23.0 Cu SIEVE ANALYSES - ASTM D 6913 6"5"4"3"2" 1- 1 / 2 " 1"3/ 4 " 1/ 2 " 3/ 8 " #4 #8 #1 0 #1 6 #2 0 #3 0 #4 0 #5 0 #6 0 #1 0 0 #2 0 0 0 10 20 30 40 50 60 70 80 90 100 0.010.11101001000 PE R C E N T P A S S I N G PARTICLE SIZE (mm) SAND SILT OR CLAY COARSE FINE COARSE MEDIUM FINE GRAVEL Qcf D10 (mm)D30 (mm)D60 (mm) 0.034 0.142 1.617 Figure 4 Cc 0.4 TEST DATA SOIL DESCRIPTION SM - Silty SAND with gravel46.9 Cu SIEVE ANALYSES - ASTM D 6913 CARLSBAD OAKS NORTH BUSINESS PARK - LOT 3 PROJECT NO.: U.S. STANDARD SIEVE SIZE 06442-32-34A SAMPLE NO.:#4 GEOLOGIC UNIT: SAMPLE DEPTH (FT.):N/A 6"5"4"3"2" 1- 1 / 2 " 1"3/ 4 " 1/ 2 " 3/ 8 " #4 #8 #1 0 #1 6 #2 0 #3 0 #4 0 #5 0 #6 0 #1 0 0 #2 0 0 0 10 20 30 40 50 60 70 80 90 100 0.010.11101001000 PE R C E N T P A S S I N G PARTICLE SIZE (mm) SAND SILT OR CLAY COARSE FINE COARSE MEDIUM FINE GRAVEL Project Name:Project No.: Pre. No. Re. AC 1 11/20/24 Whiptail Loop Rd 15+14 0.0 AC-1 149.5 143.7 96 95 AC 2 11/20/24 Whiptail Loop Rd 16+10 0.0 AC-1 149.5 144.6 97 95 AC 3 11/27/24 Whiptail Loop Rd 16+10 0.0 AC-1 149.5 145.6 97 95 AC 4 11/27/24 Whiptail Loop Rd 15+14 0.0 AC-1 149.5 145.2 97 95 AC 5 07/24/25 Whiptail Loop Rd 16+10 0.0 AC-1 149.5 144.9 97 95 AC 6 07/24/25 Whiptail Loop Rd 15+50 0.0 AC-1 149.5 144.3 97 95 AC 7 07/24/25 Whiptail Loop Rd 14+50 0.0 AC-1 149.5 143.9 96 95 AC 8 07/24/25 Whiptail Loop Rd 15+75 0.0 AC-1 149.5 143.7 96 95 AC 9 07/24/25 Whiptail Loop Rd 15+15 0.0 AC-2 149.7 144.0 96 95 AC 10 07/24/25 Whiptail Loop Rd 16+10 0.0 AC-2 149.7 144.9 97 95 AC 11 07/24/25 Whiptail Loop Rd 15+50 0.0 AC-2 149.7 145.0 97 95 AC 12 07/24/25 Whiptail Loop Rd 15+75 0.0 AC-2 149.7 144.3 96 95 AC 13 07/24/25 Whiptail Loop Rd 15+15 0.0 AC-2 149.7 144.2 96 95 Test No. Date (MM/DD/YY) Required Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Relative Compaction (%) Location Elev. or Depth (feet)Curve No. Max. Density (pcf) Field Density (pcf) Project Name:Project No.: Pre. No. Re. B 1 11/19/24 Whiptail Loop Rd 16+10 B 6 0 124.4 9.6 121.4 10.9 98 95 B 2 11/19/24 Whiptail Loop Rd 15+14 B 6 0 124.4 9.6 120.6 11.5 97 95 B 3 11/19/24 Whiptail Loop Rd 15+14 B 6 0 124.4 9.6 120.8 10.3 97 95 B 4 11/19/24 Whiptail Loop Rd 16+10 B 6 0 124.4 9.6 121.0 11.6 97 95 B 5 06/25/25 Entrance Whiptail Loop Rd 15+61 B 7 0 121.6 11.3 115.9 11.3 95 95 B 6 06/25/25 Entrance Whiptail Loop Rd 15+70 B 7 0 121.6 11.3 116.3 11.1 96 95 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. CG 1 02/06/25 N of Bldg C 0 4 0 137.7 6.8 129.5 7.0 94 95 CG 2 02/06/25 N of Bldg C 0 4 0 137.7 6.8 133.5 6.9 97 95 CG 3 02/06/25 W of Bldg C 0 4 0 137.7 6.8 131.8 7.2 96 95 CG 4 02/06/25 W of Bldg C 0 4 0 137.7 6.8 132.3 7.0 96 95 CG 5 06/10/25 S of Bldg B 0 3 10 135.5 7.2 128.3 6.9 95 95 CG 6 06/10/25 S of Bldg C 0 3 10 135.5 7.2 129.0 7.1 95 95 CG 7 06/10/25 S of Bldg C 0 3 10 135.5 7.2 129.7 6.9 96 95 CG 8 06/10/25 S of Bldg B 0 3 10 135.5 7.2 128.4 7.1 95 95 CG 9 06/23/25 Whiptail Loop Rd 14+50 314 3 0 132.8 8.0 119.1 7.3 90 95 CG 10 06/23/25 Whiptail Loop Rd 14+75 315 3 0 132.8 8.0 118.1 3.3 89 95 CG 11 06/25/25 Entrance from Whiptail Loop Rd 15+30 316 3 0 132.8 8.0 128.9 7.2 97 95 CG 12 06/25/25 Entrance from Whiptail Loop Rd 15+80 321 3 0 132.8 8.0 129.1 7.2 97 95 CG 9 A 06/25/25 Whiptail Loop Rd 14+55 314 1 0 124.0 11.6 118.5 10.8 96 95 CG 10 A 06/25/25 Whiptail Loop Rd 14+70 315 1 0 124.0 11.6 117.6 11.1 95 95 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. ET 1 03/12/25 E of Bldg C -3 2 10 133.4 8.5 124.5 8.9 93 90 ET 2 03/12/25 E of Bldg C -2 2 10 133.4 8.5 124.4 9.3 93 90 ET 3 03/12/25 E of Bldg C -1 2 10 133.4 8.5 122.9 8.6 92 90 ET 4 03/18/25 E of Bldg A -3 2 10 133.4 8.5 125.9 9.0 94 90 ET 5 03/18/25 E of Bldg A -2 2 10 133.4 8.5 125.6 9.5 94 90 ET 6 03/18/25 E of Bldg A -1 2 10 133.4 8.5 126.2 8.7 95 90 ET 7 03/18/25 E of Bldg B -3 2 10 133.4 8.5 123.4 8.8 93 90 ET 8 03/18/25 E of Bldg B -2 2 10 133.4 8.5 124.7 8.5 93 90 ET 9 03/24/25 E of Bldg C -2 2 20 136.3 7.5 124.9 7.5 92 90 ET 10 03/24/25 E of Bldg C -1 2 20 136.3 7.5 123.4 7.5 91 90 ET 11 06/24/25 South of Building B 320 1 0 124.0 11.6 113.8 10.8 92 90 ET 12 06/24/25 South of Building B 320 3 0 132.8 8.0 118.9 10.6 90 90 ET 13 06/24/25 South of Building B 321 3 0 132.8 8.0 121.5 10.7 91 90 ET 14 06/24/25 South of Building B 321 3 0 132.8 8.0 123.2 11.0 93 90 ET 15 08/11/25 Whiptail Loop/Caribou Ct -1 2 0 130.6 9.4 118.6 9.9 91 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. FS 1 10/30/24 S of Bldg A -1 2 10 133.4 8.5 122.7 8.3 92 90 FS 2 10/30/24 S of Bldg A 0 2 10 133.4 8.5 125.2 8.5 94 90 FS 3 10/30/24 S of Bldg A -1 2 10 133.4 8.5 123.9 8.1 93 90 FS 4 10/31/24 S of Bldg A 0 2 10 133.4 8.5 129.1 8.8 97 90 FS 5 10/31/24 S of Bldg A -1 2 10 133.4 8.5 125.5 8.7 94 90 FS 6 10/31/24 S of Bldg A 0 2 10 133.4 8.5 123.8 8.8 93 90 FS 7 11/01/24 E of Bldg A -1 2 10 133.4 8.5 125.6 8.9 94 90 FS 8 11/01/24 E of Bldg A 0 2 10 133.4 8.5 122.6 10.3 92 90 FS 9 11/01/24 E of Bldg A 0 2 10 133.4 8.5 124.9 9.1 94 90 FS 10 11/01/24 E of Bldg A 0 2 10 133.4 8.5 121.0 8.3 91 90 FS 11 11/01/24 E of Bldg A 0 2 10 133.4 8.5 119.7 8.5 90 90 FS 12 12/02/24 E of Bldg B -1 2 10 133.4 8.5 124.6 8.6 93 90 FS 13 12/02/24 E of Bldg B 0 2 10 133.4 8.5 123.9 8.0 93 90 FS 14 12/02/24 E of Bldg B 0 2 10 133.4 8.5 128.1 8.1 96 90 FS 15 12/02/24 N of Bldg C 0 2 10 133.4 8.5 125.3 8.3 94 90 FS 16 12/02/24 N of Bldg C 0 2 10 133.4 8.5 123.0 8.5 92 90 FS 17 12/02/24 N of Bldg C -1 2 10 133.4 8.5 126.5 8.3 95 90 FS 18 12/03/24 N of Bldg C 0 2 10 133.4 8.5 124.9 8.4 94 90 FS 19 12/03/24 W of Bldg C 0 2 10 133.4 8.5 122.6 8.9 92 90 FS 20 12/03/24 W of Bldg C 0 2 10 133.4 8.5 123.6 8.8 93 90 FS 21 12/03/24 W of Bldg B -1 2 10 133.4 8.5 126.2 8.0 95 90 FS 22 12/03/24 W of Bldg B 0 2 10 133.4 8.5 125.5 8.2 94 90 FS 23 12/03/24 W of Bldg B 0 2 10 133.4 8.5 123.8 9.0 93 90 FS 24 12/03/24 W of Bldg B 0 2 10 133.4 8.5 126.3 8.4 95 90 FS 25 02/05/25 E of Bldg A -2 2 10 133.4 8.5 127.6 8.5 96 90 FS 26 02/05/25 E of Bldg A -1 2 10 133.4 8.5 129.3 8.8 97 90 FS 27 02/05/25 E of Bldg A 0 2 10 133.4 8.5 127.8 8.5 96 90 FS 28 02/05/25 E of Bldg A -3 2 10 133.4 8.5 126.5 8.9 95 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B FS 29 02/05/25 E of Bldg A -2 2 10 133.4 8.5 124.9 9.4 94 90 FS 30 02/05/25 E of Bldg A -1 2 10 133.4 8.5 128.2 8.6 96 90 Project Name:Project No.: Pre. No. Re. GT 1 05-27-25 Bldg A 0 3 5 134.1 7.6 120.6 7.6 90 90 GT 2 05/27/25 Bldg B 0 3 5 134.1 7.6 121.9 8.2 91 90 GT 3 05/27/25 N of Bldg B 0 3 5 134.1 7.6 121.2 8.0 90 90 GT 4 05/27/25 East of Bldg B -2 3 5 134.1 7.6 119.6 8.9 89 90 GT 4 A 05/27/25 East of Bldg B -2 3 5 134.1 7.6 122.1 7.6 91 90 GT 5 05/27/25 East of Bldg B 0 3 5 134.1 7.6 120.8 7.7 90 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. MG 1 01/13/25 Slope Above MSE Wall 0 + 40 333 3 0 132.8 8.0 124.1 7.6 93 90 MG 2 01/13/25 Slope Above MSE Wall 0 + 80 333 3 0 132.8 8.0 118.9 7.1 90 90 MG 3 01/13/25 Slope Above MSE Wall 0 + 55 334 3 0 132.8 8.0 119.0 7.2 90 90 MG 4 01/13/25 Slope Above MSE Wall 0 + 90 334 3 0 132.8 8.0 120.6 7.4 91 90 MG 5 01/28/25 Slope Above MSE Wall 4+00 327 3 0 132.8 8.0 121.1 10.5 91 90 MG 6 01/28/25 Slope Above MSE Wall 3+70 328 3 0 132.8 8.0 123.4 8.4 93 90 MG 7 01/28/25 Slope Above MSE Wall 3+40 331 3 0 132.8 8.0 123.9 8.2 93 90 MG 8 01/28/25 Slope Above MSE Wall 3+10 332 3 0 132.8 8.0 122.6 8.3 92 90 MG 9 01/29/25 Slope Above MSE Wall 2+95 333 3 0 132.8 8.0 123.5 8.8 93 90 MG 10 01/29/25 Slope Above MSE Wall 2+75 334 3 0 132.8 8.0 122.8 8.5 92 90 MG 11 01/29/25 Slope Above MSE Wall 2+55 332 3 0 132.8 8.0 121.9 8.0 92 90 MG 12 01/30/25 Slope Above MSE Wall 2+45 333 4 0 137.7 6.8 127.2 7.4 92 90 MG 13 01/30/25 Slope Above MSE Wall 2+25 336 4 0 137.7 6.8 124.9 7.2 91 90 MG 14 01/30/25 Slope Above MSE Wall 2+05 335 4 0 137.7 6.8 128.4 6.8 93 90 MG 15 01/30/25 Slope Above MSE Wall 1+85 335 4 0 137.7 6.8 127.7 7.0 93 90 MG 16 01/31/25 Slope Above MSE Wall 1+50 333 4 0 137.7 6.8 124.0 7.0 90 90 MG 17 01/31/25 Slope Above MSE Wall 1+10 334 4 0 137.7 6.8 123.5 6.8 90 90 MG 18 01/31/25 Slope Above MSE Wall 0+75 335 4 0 137.7 6.8 126.6 7.4 92 90 MG 19 01/31/25 Slope Above MSE Wall 0+30 334 4 0 137.7 6.8 124.2 6.9 90 90 MG 20 02/26/25 Between Bldgs B & C 320 3 10 135.5 7.2 121.3 7.3 90 90 MG 21 02/26/25 Between Bldgs B & C 320 3 10 135.5 7.2 121.7 7.6 90 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. PT 1 09/05/24 Bldg A -1 2 0 130.6 9.4 121.4 8.9 93 90 PT 2 09/05/24 Bldg A -1 2 0 130.6 9.4 122.6 9.4 94 90 PT 3 09/05/24 Bldg A -1 2 0 130.6 9.4 126.1 9.4 97 90 PT 4 09/05/24 Bldg A 0 2 0 130.6 9.4 122.3 9.7 94 90 PT 5 09/05/24 Bldg A 0 2 0 130.6 9.4 121.0 9.5 93 90 PT 6 09/06/24 Bldg A -1 2 0 130.6 9.4 120.6 8.6 92 90 PT 7 09/06/24 Bldg A 0 2 0 130.6 9.4 117.4 9.0 90 90 PT 8 09/06/24 Bldg A 0 2 0 130.6 9.4 118.3 9.1 91 90 PT 9 09/06/24 Bldg B 0 2 0 130.6 9.4 117.8 8.2 90 90 PT 10 09/06/24 Bldg B 0 2 0 130.6 9.4 119.6 8.9 92 90 PT 11 09/06/24 Bldg B 0 2 0 130.6 9.4 120.3 9.0 92 90 PT 12 09/06/24 Bldg B 0 2 0 130.6 9.4 120.7 8.8 92 90 PT 13 09/17/24 Bldg C -1 2 10 133.4 8.5 126.0 7.9 94 90 PT 14 09/17/24 Bldg C 0 2 10 133.4 8.5 124.3 8.3 93 90 PT 15 09/17/24 Bldg C 0 2 10 133.4 8.5 122.8 8.7 92 90 PT 16 09/17/24 Bldg C 0 2 10 133.4 8.5 121.5 7.9 91 90 PT 17 09/17/24 Bldg C 0 2 10 133.4 8.5 122.2 8.5 92 90 PT 18 09/17/24 Bldg C 0 2 10 133.4 8.5 121.4 8.2 91 90 PT 19 09/18/24 Bldg C 0 2 10 133.4 8.5 124.6 8.7 93 90 PT 20 09/18/24 Bldg C 0 2 10 133.4 8.5 120.3 8.1 90 90 PT 21 09/18/24 Bldg C 0 2 10 133.4 8.5 123.6 8.5 93 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. SD 1 08/29/24 Line 5 -4 2 10 133.4 8.5 123.8 8.3 93 90 SD 2 08/29/24 Line 5 -2 2 10 133.4 8.5 127.4 8.5 95 90 SD 3 08/30/24 Line 4 -3 2 10 133.4 8.5 123.9 9.1 93 90 SD 4 08/30/24 Line 4 -1 2 20 136.3 7.5 126.7 7.7 93 90 SD 5 08/30/24 Line 4 -4 2 20 136.3 7.5 125.3 8.8 92 90 SD 6 08/30/24 Line 4 -2 2 20 136.3 7.5 127.8 7.2 94 90 SD 7 09/03/24 Line 5 -3 2 20 136.3 7.5 129.4 7.6 95 90 SD 8 09/03/24 Line 5 -1 2 20 136.3 7.5 126.6 7.9 93 90 SD 9 09/27/24 Box 15 -7 2 20 136.3 7.5 124.4 7.8 91 90 SD 10 09/27/24 Box 15 -6 2 20 136.3 7.5 127.1 7.3 93 90 SD 11 09/27/24 Box 15 -5 2 20 136.3 7.5 125.7 7.5 92 90 SD 12 09/27/24 Box 15 -5 2 20 136.3 7.5 128.4 7.6 94 90 SD 13 10/02/24 LINE 2-3 -1 2 20 136.3 7.5 125.8 7.2 92 90 SD 14 10/02/24 LINE 2-3 -1 2 20 136.3 7.5 125.7 7.8 92 90 SD 15 R 10/02/24 LINE 3-4 -2 2 20 136.3 7.5 118.4 5.0 87 90 SD 16 10/02/24 LINE 3-4 -2 2 20 136.3 7.5 115.2 8.0 84 90 SD 17 10/02/24 LINE 3 -3 2 0 130.6 9.4 119.1 4.7 91 90 SD 18 10/02/24 LINE 3-4 -4 2 0 130.6 9.4 118.8 5.6 91 90 SD 19 10/02/24 LINE 3-4 -2 2 0 130.6 9.4 119.7 6.6 92 90 SD 20 10/02/24 Line 4&5 -2 2 10 133.4 8.5 125.7 8.2 94 90 SD 21 10/02/24 Line 4&5 -1 2 10 133.4 8.5 122.5 8.6 92 90 SD 16 A 10/02/24 LINE 3-4 -3 2 0 130.6 9.4 120.8 9.7 92 90 SD 22 10/02/24 LINE 3-4 -2 2 0 130.6 9.4 121.3 9.4 93 90 SD 23 10/02/24 LINE 3-4 -2 2 0 130.6 9.4 119.4 10.3 91 90 SD 24 10/02/24 LINE 3-4 -1 2 0 130.6 9.4 119.8 10.5 92 90 SD 25 10/02/24 LINE 3-4 -1 2 0 130.6 9.4 120.0 10.2 92 90 SD 26 02/10/25 LINE 1 0 4 0 137.7 6.8 126.2 7.9 92 90 SD 27 02/10/25 LINE 1 0 4 0 137.7 6.8 125.8 7.5 91 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B SD 28 02/21/25 LINE 9 -1 4 0 137.7 6.8 124.7 8.0 91 90 SD 29 02/21/25 LINE 9 0 4 0 137.7 6.8 127.2 7.6 92 90 SD 30 02/21/25 LINE 7 0 4 0 137.7 6.8 127.8 6.9 93 90 SD 31 02/21/25 LINE 8 -1 4 0 137.7 6.8 126.4 7.3 92 90 SD 32 02/21/25 LINE 6 0 4 0 137.7 6.8 125.9 7.1 91 90 SD 33 02/21/25 LINE 10 0 4 0 137.7 6.8 125.6 7.8 91 90 SD 34 02/21/25 LINE 10 0 4 0 137.7 6.8 126.0 7.2 92 90 Project Name:Project No.: Pre. No. Re. SG 1 02/04/25 N OF BLDG C 0 4 10 140.1 6.1 132.7 7.6 95 95 SG 2 02/04/25 N OF BLDG C 0 4 10 140.1 6.1 132.9 6.8 95 95 SG 3 02/04/25 N OF BLDG C 0 4 10 140.1 6.1 132.8 6.9 95 95 SG 4 02/04/25 N OF BLDG C 0 4 10 140.1 6.1 135.2 7.0 96 95 SG 5 02/06/25 W OF BLDG C 0 4 10 140.1 6.1 132.5 7.3 95 95 SG 6 02/06/25 W OF BLDG C 0 4 10 140.1 6.1 135.3 7.7 97 95 SG 7 02/06/25 W OF BLDG C 0 4 10 140.1 6.1 133.7 7.1 95 95 SG 8 02/06/25 W OF BLDG C 0 4 10 140.1 6.1 135.3 6.9 97 95 SG 9 02/06/25 W OF BLDG C 0 4 10 140.1 6.1 132.9 6.9 95 95 SG 10 02/11/25 W OF BLDG B 0 4 10 140.1 6.1 133.5 7.3 95 95 SG 11 02/11/25 W OF BLDG B 0 4 10 140.1 6.1 130.4 6.8 93 95 SG 12 02/11/25 W OF BLDG B 0 4 10 140.1 6.1 135.6 6.6 97 95 SG 13 02/11/25 W OF BLDG B 0 4 10 140.1 6.1 135.1 7.0 96 95 SG 14 02/11/25 E OF BLDG C 0 4 10 140.1 6.1 133.8 6.8 95 95 SG 15 02/11/25 E OF BLDG C 0 4 10 140.1 6.1 131.4 8.0 94 95 SG 16 02/11/25 E OF BLDG C 0 4 10 140.1 6.1 132.7 7.2 95 95 SG 17 02/11/25 E OF BLDG C 0 4 10 140.1 6.1 134.0 6.9 96 95 SG 18 02/20/25 between BLDG's A-B 0 4 10 140.1 6.1 133.5 7.9 95 95 SG 19 02/20/25 between BLDG's A-B 0 4 5 138.9 6.5 131.9 7.5 95 95 SG 20 02/20/25 between BLDG's A-B 0 4 5 138.9 6.5 132.3 7.7 95 95 SG 21 02/24/25 E OF BLDG C 0 3 10 135.5 7.2 126.8 8.2 94 95 SG 22 02/24/25 E OF BLDG C 0 3 10 135.5 7.2 127.1 8.0 94 95 SG 23 02/24/25 E OF BLDG C 0 3 10 135.5 7.2 125.7 8.1 93 95 SG 24 02/25/25 E OF BLDG C trash enclosure 0 3 10 135.5 7.2 124.8 7.4 92 90 SG 25 02/25/25 W OF BLDG A 0 3 5 134.1 7.6 126.9 7.2 95 95 SG 26 02/25/25 W OF BLDG A 0 3 5 134.1 7.6 127.5 7.4 95 95 SG 27 02/25/25 W OF BLDG A 0 3 5 134.1 7.6 128.5 7.8 96 95 SG 28 02/27/25 N OF BLDG C 0 3 5 134.1 7.6 128.3 7.8 96 95 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B SG 29 02/27/25 N OF BLDG C 0 3 5 134.1 7.6 126.8 7.6 95 95 SG 30 02/27/25 N OF BLDG C 0 3 5 134.1 7.6 126.9 7.6 95 95 SG 31 02/28/25 E OF BLDG C 0 3 5 134.1 7.6 127.6 7.8 95 95 SG 32 02/28/25 E OF BLDG C 0 3 5 134.1 7.6 129.1 7.6 96 95 SG 33 02/28/25 E OF BLDG C 0 3 5 134.1 7.6 130.4 7.9 97 95 SG 34 02/28/25 E OF BLDG C 0 3 5 134.1 7.6 129.6 7.6 97 95 SG 35 03/03/25 W OF BLDG C 0 3 5 134.1 7.6 128.3 7.7 96 95 SG 36 03/03/25 W OF BLDG C 0 3 5 134.1 7.6 127.9 7.6 95 95 SG 37 03/03/25 W OF BLDG C 0 3 5 134.1 7.6 127.5 7.6 95 95 SG 38 03/04/25 W OF BLDG C 0 3 5 134.1 7.6 129.2 7.9 96 95 SG 39 03/04/25 W OF BLDG C 0 3 5 134.1 7.6 126.9 8.1 95 95 SG 40 03/04/25 W OF BLDG C 0 3 5 134.1 7.6 130.4 7.5 97 95 SG 41 03/05/25 W OF BLDG C 0 3 10 135.5 7.2 130.1 7.4 96 95 SG 42 03/05/25 W OF BLDG C 0 3 10 135.5 7.2 126.8 7.8 94 95 SG 43 03/05/25 W OF BLDG C 0 3 10 135.5 7.2 132.1 7.3 98 95 SG 44 03/05/25 W OF BLDG C 0 3 10 135.5 7.2 132.6 7.2 98 95 SG 45 06/10/25 S OF BLDG B 0 3 10 135.5 7.2 128.1 7.0 95 95 SG 46 06/10/25 S OF BLDG C 0 3 10 135.5 7.2 130.2 6.4 96 95 SG 47 06/10/25 S OF BLDG C 0 3 10 135.5 7.2 131.8 7.0 97 95 SG 48 06/10/25 S OF BLDG B 0 3 10 135.5 7.2 128.2 7.6 95 95 SG 49 06/11/25 S OF BLDG A 0 3 10 135.5 7.2 129.5 7.9 96 95 SG 50 06/11/25 Road S of Building A 0 3 10 135.5 7.2 129.9 7.0 96 95 SG 51 06/18/25 Entry Driveway 0 3 10 135.5 7.2 130.4 7.0 96 95 SG 52 06/18/25 Entry Driveway 0 3 10 135.5 7.2 129.0 7.5 95 95 SG 53 06/25/25 South of Building B 0 3 10 135.5 7.2 129.5 7.9 96 95 SG 54 06/25/25 South of Building B 0 3 10 135.5 7.2 128.7 8.2 95 95 SG 55 06/25/25 South of Building B 0 3 10 135.5 7.2 128.9 7.7 95 95 Project Name:Project No.: Pre. No. Re. Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B SG 56 06/25/25 Entrance from Whiptail Loop Dr 0 3 10 135.5 7.2 129.5 8.0 96 95 SG 57 07/01/25 South of Building B 0 3 10 135.5 7.2 133.2 6.3 98 95 SG 58 07/01/25 South of Building B 0 3 10 135.5 7.2 132.2 6.6 98 95 SG 59 07/01/25 South of Building C 0 3 10 135.5 7.2 133.4 6.8 98 95 Project Name:Project No.: Pre. No. Re. SW 1 04/29/25 W of Bldg C 0 3 0 132.8 8.0 122.8 7.6 92 90 SW 2 04/29/25 W of Bldg C 0 3 0 132.8 8.0 119.9 8.0 90 90 SW 3 04/29/25 W of Bldg C 0 3 0 132.8 8.0 122.2 8.0 92 90 SW 4 04/29/25 W of Bldg C 0 3 0 132.8 8.0 124.6 8.3 94 90 SW 5 04/29/25 W of Bldg C 0 3 0 132.8 8.0 128.6 7.3 97 90 SW 6 04/29/25 W of Bldg B 0 3 0 132.8 8.0 124.5 7.4 94 90 SW 7 04/29/25 W of Bldgs B 0 3 0 132.8 8.0 127.9 7.7 96 90 SW 8 04/29/25 W of Bldg A 0 3 0 132.8 8.0 122.8 8.6 92 90 SW 9 04/29/25 S of Bldg A 0 3 0 132.8 8.0 123.1 8.0 93 90 SW 10 04/29/25 S of Bldg A 0 3 0 132.8 8.0 122.2 7.3 92 90 SW 11 06/23/25 Whiptail Loop Rd 14+90 315 3 0 132.8 8.0 116.7 4.4 88 90 SW 12 06/23/25 Whiptail Loop Rd 14+40 315 3 0 132.8 8.0 115.2 3.5 87 90 SW 13 06/25/25 Entrance from Whiptail Loop Rd 15+85 318 3 0 132.8 8.0 127.3 7.1 96 90 SW 11 A 06/25/25 Whiptail Loop Rd 14+80 315 3 0 132.8 8.0 122.3 7.7 92 90 SW 12 A 06/25/25 Whiptail Loop Rd 14+50 318 3 0 132.8 8.0 121.7 8.0 92 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. SM 1 12/31/24 E Bldg A 317 2 0 130.6 9.4 119.4 10.2 91 90 SM 2 12/31/24 E Bldg A 316 2 10 133.4 8.5 125.1 8.1 94 90 SM 3 01/02/25 E Bldg A 316 2 10 133.4 8.5 124.1 8.5 93 90 SM 4 01/02/25 E Bldg A 316 2 10 133.4 8.5 123.2 8.0 92 90 SM 5 01/02/25 E Bldg A 316 2 10 133.4 8.5 122.5 10.2 92 90 SM 6 01/02/25 E Bldg B 316 2 10 133.4 8.5 123.6 7.5 93 90 SM 7 01/03/25 E Bldg B 317 2 10 133.4 8.5 120.2 9.2 90 90 SM 8 01/03/25 Bldg B & C 320 2 10 133.4 8.5 123.2 8.7 92 90 SM 9 01/03/25 Bldg B & C 320 2 10 133.4 8.5 119.9 7.8 90 90 SM 10 01/07/25 E Bldg A -5 2 20 136.3 7.5 127.5 7.2 94 90 SM 11 01/07/25 E Bldg A -3 2 20 136.3 7.5 127.9 7.6 94 90 SM 12 01/07/25 E Bldg A -1 2 20 136.3 7.5 128.1 7.5 94 90 SM 13 01/07/25 E Bldg B 0 2 20 136.3 7.5 126.6 7.3 93 90 SM 14 01/07/25 S Bldg C 0 2 20 136.3 7.5 128.8 7.5 94 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. WB 1 11/05/24 MSE Wall 1 0+75 325 3 0 132.8 8.0 121.4 8.6 91 90 WB 2 11/05/24 MSE Wall 1 1+50 325 3 0 132.8 8.0 124.8 8.0 94 90 WB 3 11/06/24 MSE Wall 1 0+25 326 3 0 132.8 8.0 128.3 8.4 97 90 WB 4 11/06/24 MSE Wall 1 1+00 327 3 0 132.8 8.0 127.9 8.9 96 90 WB 5 11/07/24 MSE Wall 1 1+75 327 3 0 132.8 8.0 128.0 7.9 96 90 WB 6 11/07/24 MSE Wall 1 2+60 327 3 0 132.8 8.0 128.7 8.0 97 90 WB 7 11/08/24 MSE Wall 1 0+75 327 3 0 132.8 8.0 126.2 8.6 95 90 WB 8 11/08/24 MSE Wall 1 2+00 328 3 0 132.8 8.0 124.9 8.9 94 90 WB 9 11/08/24 MSE Wall 1 3+25 324 3 0 132.8 8.0 127.3 8.2 96 90 WB 10 11/08/24 MSE Wall 1 1+35 328 3 0 132.8 8.0 125.5 8.4 95 90 WB 11 11/11/24 MSE Wall 1 0+40 328 3 0 132.8 8.0 126.0 7.6 95 90 WB 12 11/11/24 MSE Wall 1 1+15 329 3 0 132.8 8.0 124.5 8.5 94 90 WB 13 11/12/24 MSE Wall 1 1+80 329 3 0 132.8 8.0 123.8 8.1 93 WB WB 14 11/12/24 MSE Wall 1 3+50 323 3 0 132.8 8.0 124.7 7.7 94 90 WB 15 11/12/24 MSE Wall 1 3+85 323 3 0 132.8 8.0 127.4 8.2 96 90 WB 16 11/12/24 MSE Wall 1 3+60 325 3 0 132.8 8.3 125.0 7.9 94 90 WB 17 11/13/24 MSE Wall 1 3+30 327 3 0 132.8 8.0 126.0 8.0 95 90 WB 18 11/13/24 MSE Wall 1 2+20 328 3 0 132.8 8.0 124.8 8.4 94 90 WB 19 11/13/24 MSE Wall 1 1+60 329 3 0 132.8 8.0 122.9 8.7 93 90 WB 20 11/13/24 MSE Wall 1 0+40 329 3 0 132.8 8.0 125.4 8.4 94 90 WB 21 11/14/24 MSE Wall 1 3+45 326 3 0 132.8 8.0 128.9 8.3 97 90 WB 22 11/14/24 MSE Wall 1 3+70 327 3 0 132.8 8.0 126.2 8.0 95 90 WB 23 11/14/24 MSE Wall 1 4+00 324 3 0 132.8 8.0 123.6 8.9 93 90 WB 24 11/15/24 MSE Wall 1 0+60 329 3 0 132.8 8.0 128.4 7.9 97 90 WB 25 11/15/24 MSE Wall 1 1+50 330 3 0 132.8 8.0 125.1 8.2 94 90 WB 26 11/15/24 MSE Wall 1 2+10 330 3 0 132.8 8.0 126.8 7.9 95 90 WB 27 11/15/24 MSE Wall 1 2+95 329 3 0 132.8 8.0 125.4 8.4 94 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B Project Name:Project No.: Pre. No. Re. WM 1 11/07/24 Whiptail Loop Tie-In 15+14 -1 1 0 124.0 11.6 117.5 11.9 95 90 WM 2 11/07/24 Whiptail Loop Tie-In 15+14 0 5 0 132.4 8.3 126.5 8.6 96 90 WM 3 11/14/24 Whiptail Loop Tie-In 15+14 -1 1 0 124.0 11.6 119.4 10.2 96 90 WM 4 11/14/24 Whiptail Loop Tie-In 15+14 0 1 0 124.0 11.6 118.0 10.3 95 90 WM 5 11/15/24 Whiptail Loop Tie-In 15+90 -1 1 0 124.0 11.6 120.8 11.7 97 90 WM 6 11/15/24 Whiptail Loop Tie-In 15+90 -1 1 0 124.0 11.6 121.6 11.4 98 90 WM 7 11/18/24 Whiptail Loop Tie-In 16+10 -1 1 0 124.0 11.6 118.3 11.8 95 90 WM 8 11/18/24 Whiptail Loop Tie-In 16+10 -1 1 0 124.0 11.6 119.9 11.6 97 90 WM 9 11/19/24 Whiptail Loop Tie-In 16+10 -1 1 0 124.0 11.6 117.2 10.7 95 90 WM 10 11/19/24 Whiptail Loop Tie-In 16+10 -1 1 0 124.0 11.6 117.8 11.2 95 90 WM 11 01/23/25 NE of Bldg B -1 3 0 132.8 8.0 124.5 8.7 94 90 WM 12 01/23/25 NE of Bldg B -1 3 0 132.8 8.0 122.9 9.0 93 90 WM 13 01/23/25 NE of Bldg B -1 3 0 132.8 8.0 122.2 9.5 92 90 WM 14 01/23/25 N of Bldg B 0 3 0 132.8 8.0 121.6 9.4 92 90 Required Relative Compaction (%) Test No. Date (MM/DD/YY) Curve No. >¾" Rock (%) Location Elev. or Depth (feet) Max. Dry Density (pcf) Opt. Moist Content (%) Field Dry Density (pcf) Field Moisture Content (%) Relative Compaction (%) TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS Carlsbad Oaks North Business Park, Lot 3 06442-32-34B AC Asphalt Concrete IT Irrigation Trench SG Subgrade AD Area Drain JT Joint Trench SL Sewer Lateral B Base M Moisture Test SM Sewer Main CG Curb/Gutter MG Minor Grading SR Slope Repair DW Driveway MSE Mechanically Stabilized Earth Wall ST Slope Test ET Electrical Trench PT Plumbing Trench SW Sidewalk ETB Exploratory Trench RG Regrade SZ Slope Zone FB Footing Backfill RWL Reclaimed Water Lateral UT Utility Trench FG Finish Grade RWM Reclaimed Water Main WB Wall Backfill FS Fire Service SBT Subdrain Trench WL Water Lateral GT Gas Trench SD Storm Drain WM Water Main A, B, C, … R *SC Denotes Sandcone Density Test Fill in area of density test was removed during construction operations ELEVATION OR DEPTH TABLE I SUMMARY OF FIELD DENSITY TEST RESULTS TEST NO. - PREFIX TEST NO. - RE. Retest of previous density test failure following additional moisture conditioning or recompaction Corresponds to the elevation or the depth, in feet, of the in-place density/moisture content test. The value has been rounded to the nearest whole foot. CURVE NO. Corresponds to the curve numbers presented in the summary of the laboratory maximum dry density and optimum moisture content test results. The field representative selected the curve no. based on the laboratory test results and field observations. >¾" ROCK - ROCK CORRECTION The laboratory maximum dry density and optimum moisture content can be adjusted for in-place soil that possesses rock larger than ¾ inch. The curve no. is adjusted for the percentage of ¾ inch rock in accordance with ASTM D 4718 or Woodward Clyde guidelines. Carlsbad Oaks North Business Park – Lot 3 Final Report of Testing and Observation Services Performed During Improvement Construction Project No. 06442-32-34B August 29, 2025 TABLE II SUMMARY OF LABORATORY MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT TEST RESULTS ASTM D 1557 Sample No. Description Maximum Dry Density (pcf) Optimum Moisture Content (% dry wt.) 1 Yellowish brown, Silty, fine to coarse SAND with little gravel and trace clay 124.0 11.6 2 Yellowish brown to brown, Silty, fine to coarse SAND with few to little gravel and trace clay 130.6 9.4 3 Yellowish brown to brown, Silty, fine to coarse SAND with little gravel and few clay 132.8 8.0 4 Dark grayish brown, Silty, f-c SAND with little gravel and trace clay (Import - ERTC) 137.7 6.8 5 Yellowish brown, Silty, fine to medium SAND with little gravel and trace clay (Import - Ionis Pharmaceuticals Lots 21&22) 132.4 8.3 6 Dark grayish brown, Gravelly SAND with trace silt (Import Recycled Class II Base) 124.4 9.6 7 Grayish brown, Gravelly SAND with trace silt (Import Recycled Class II Base) 121.6 11.3 TABLE III SUMMARY OF ATTERBERG LIMITS TEST RESULTS ASTM D 4318 Sample No.* Liquid Limit Plastic Limit Plasticity Index 3 34 21 13 4* 0 0 0 *Non-Plastic. TABLE IV SUMMARY OF LABORATORY TEST RESULTS FOR ASPHALT CONCRETE Sample No. Test Greenbook Specifications Aggregate Size (inch) Theoretical Maximum Density (pcf) Hveem Maximum Density (pcf) Air Voids (%) Stability Air Voids (%) Stability AC-1 ¾ 156.6 149.8 4.6 45 3-6 >35 AC-2 ½ 155.0 149.7 3.4 39 3-6 >35 Carlsbad Oaks North Business Park – Lot 3 Final Report of Testing and Observation Services Performed During Improvement Construction Project No. 06442-32-34B August 29, 2025 TABLE V SUMMARY OF LABORATORY ASPHALT CONCRETE GRADATION AND ASPHALT CONTENT TEST RESULTS ASTM C 136 AND D 6307 Sieve Analysis ASTM C 136 (sieve size / test type) 3/4-Inch Asphalt Concrete Sample No. Green Book Section 400-4.3 Specifications Class B3 (% passing) AC-1 1 inch 100 100 ¾ inch 100 90-100 ½ inch 90 85-100 ⅜ inch 79 60-84 No. 4 55 40-60 No. 8 38 24-50 No. 30 19 11-29 No. 200 5 1-9 Oil Content (%)* 5.7 4.6-6.0 *Designated as “Asphalt %” in Greenbook. TABLE VI SUMMARY OF LABORATORY ASPHALT CONCRETE GRADATION AND ASPHALT CONTENT TEST RESULTS Sieve Analysis ASTM C 136 (sieve size / test type) ½-Inch Aggregate Greenbook Section 203-6.5.4 Class C3 (% passing) AC-2 (% passing) ¾ inch 100 100 ½ inch 96 95-100 ⅜ inch 84 80-95 No. 4 58 55-72 No. 8 41 38-55 No. 30 22 18-33 No. 200 5 4-8 Oil Content (%)* ASTM D 6307 5.9 4.6-7.0 *Greenbook refers to as “Asphalt %”.