HomeMy WebLinkAboutPRE 2026-0001; HOOVER STREET SITE; Admin Decision LetterFebruary 25, 2026
Adam Kooienga
Hofman Planning
5900 Pasteur Court
Carlsbad, CA 92008
SUBJECT: PRE 2026-0001 {DEV2026-0003} -HOOVER STREET SITE
APN 206-171-03-00
{city of
Carlsbad
VIA EMAIL AND MAIL
Thank you for submitting a preliminary review application/informational request regarding a potential
residential development of either condominium units or a subdivision of single-family homes proposed at
the western end of the Hoover Street cul-de-sac bordering the Agua Hedionda Lagoon. The project site,
an approximately 1.4-acre site, currently is undeveloped. No preliminary site plan or other exhibits were
included with this application.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: Residential, R-4 (0-4 dwelling units per acre)
b. Zoning: One-Family Residential, 15,000 square foot minimum lot size (R-1-15,000)
c. The property is located in the Coastal Zone. The Coastal land use designation and zone are the
same as the general plan and zoning discussed above.
This project site is subject to the Agua Hedionda Segment of the Local Coastal Program {LCP).
Please be aware that the California Coastal Commission has permit authority for this location.
A Coastal Development Permit (CDP), issued by the California Coastal Commission, would be
required for any development proposal on this site subsequent to any other city actions on the
project. The policies of the Agua Hedionda Segment of the LCP would be enforced by the CCC
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003) -HOOVER STREET SITE
February 25, 2026
Page 2
during their review of the CDP. You will want to review these policies for understanding. It is
highly recommended that you meet and discuss any proposal for this site with the San Diego
branch of the California Coastal Commission prior to making a formal application submittal to
the city.
2. A potential residential development of either condominium units or a subdivision of single-family
homes on this undeveloped site will require the following permits from the City of Carlsbad:
a. Minor Subdivision (MS). A MS is an administrative permit that would be required for division
of land into four (4) or fewer lots or condominium units; or
b. Carlsbad Tract Map (CT). A CT is a discretionary permit that would be required for division of
land into five (5) or more lots or condominium units.
c. Planned Unit Development (PUD) Permit. A PUD is required for development of one-family
dwellings or twin-homes on lots of less than seven thousand five hundred square feet or as
otherwise allowed by the underlying zone, attached or detached condominiums, and private
streets. (CMC Section 21.45.020.A).
d. Minor Habitat Management Plan (HMP) Permit.
Please be aware that a minor permit has an administrative (City Planner) review and approval process
unless other permits require the decision to be elevated to the Planning Commission or City Council.
In these instances, all permits are elevated to the Planning Commission or City Council for decision
according to procedures outlined in CMC Section 21.54.040.
3. The project requires the following permits from the California Coastal Commission:
d. Coastal Development Permit (CDP). Submittal of an application for CDP to the California
Coastal Commission would be subsequent to the City's action on the project.
4. Slope Analysis/Vegetation Constraints Map. Any development proposal that affects steep slopes
(twenty-five percent inclination or greater) shall be required to prepare a slope map and analysis for
the affected slopes. Please review the development standards outlined in CMC Section 21.203.040
and submit all necessary information where applicable.
5. Applicant Questions/Staff Responses:
a. How many condominium units could be permitted on this site?
Staff Response: Cannot determine based on limited information provided. Please be aware
that project density, based on net developable acreage, is how the Carlsbad Municipal Code, Title
21, calculates density. The entirety ofTitle 21 is adopted as part of the City's local Coastal Program
Implementation Plan. For more specifics, please see Carlsbad Municipal Code (CMC) §21.53.230.
b. How many single-family homes could be permitted on this site?
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003) -HOOVER STREET SITE
February 25, 2026
Pa e 3
Staff Response: Cannot determine based on limited information provided (See response to
Question Sa above).
c. After review of the HMP we have identified that there are Hardline Conservation areas onsite.
• To develop the site would there be required buffers from the Hardline areas?
Staff Response: The Agua Hedionda Lagoon and a portion of the subject property is mapped
in the HMP as existing hardline (see HMP Figure 28). A formal application submittal for a
residential project would need to evaluate itself against the "additional conservation
standards to be applied to properties in the coastal zone" as discussed is the city's Habitat
Management Plan (HMP) beginning on page D-114. All buffers are discussed in Section 7-11.
• Would development of the site trigger any mitigation requirements?
Staff Response: Cannot determine based on information provided.
d. With biologically sensitive habitat on site, would the applicant be able to go through the
planned development process to develop condominium units onsite?
Staff Response: Cannot determine based on the information provided. However, in the R-1
Zone, One-Family Dwelling or Twin-Home on Small Lots (one unit per lot); or a Condominium
Project consisting of One-family dwellings, Two-family dwellings or Multiple-family dwelling
are permitted when the project site contains sensitive biological resources as identified in the
Carlsbad Habitat Management Plan. In the case of a condominium project, attached or detached
units may be permitted when the site contains sensitive biological resources. (CMC Section
21.45.040, Table A, Footnote 4)
e. If the site is developed with single-family homes, would each lot be eligible to include both an
Accessory Dwelling Unit (ADU) and a Junior Accessory Dwelling Unit (JADU)?
Staff Response: Any dwelling unit, including ADUs, are considered dwelling units and must be
included in, or as separate, Coastal Development Permits consistent with the existing
regulations. There are limited cases where existing conversions can be considered exempt,
but not in this location. Consistent with the Carlsbad Municipal Code, one (1) ADU and one
(1) JADU could be considered allowed.
f. What technical studies would the city require for this type of development at this location?
Staff Response: As part of a formal application submittal, Developer shall consult with a
professional environmental consultant to initiate preparation of a CEQA Environmental Initial
Study. Technical studies are required to support any findings in your CEQA Environmental
Initial Study and will need to be listed in an appendix to said document. As it relates to any
studies provided, please be aware of the following:
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003} -HOOVER STREET SITE
February 25, 2026
Page 4
Biological Resource Studies. As it relates to biological resource studies, your environmental
consultant will want to refer to the city's Guidelines for Biological Studies (2022) linked below:
https://www.carlsbadca.gov/home/showpublisheddocument/1604/637819050500430000
Tribal. Cultural and/or Paleontological Resources Studies. As it relates to any tribal, cultural
and/or paleontological resources studies, your environmental consultant will want to refer
to the Carlsbad Tribal, Cultural and Paleontological Resources Guidelines linked below:
https://www.carlsbadca.gov/home/showpublisheddocument/254/637425976516870000
Geotechnical/Soils Report. In addition to the typical submittal requirements of a preliminary
geotechnical/soils report, please be sure to also address specific requirements listed under the
Coastal Resources Protection Overlay Zone (CMC Chapter 21.203). More specifically, pursuant to
CMC Section 21.203 .040.C -Landslide and Slope Instability, developments within five hundred
feet of areas identified generally in the PRC Toups report, Figure 8, as containing soils of the La
Jolla group (susceptible to accelerated erosion) or landslide prone areas shall be required to
submit additional geologic reports containing the additional information required in the Coastal
Shoreline Development Overlay Zone. Additionally, pursuant to CMC Section 21.203.040.D -
Seismic Hazards, development in liquefaction-prone areas shall include site-specific investigations
addressing the liquefaction problem and suggesting mitigation measures. New residential
development in excess of four units, commercial, industrial, and public facilities shall have site-
specific geologic investigations completed in known potential liquefaction areas.
g. If planned development is required, would it be major or minor planned development permit?
Staff Response: This would be dependent on whether the project is proposing a Major
Subdivision (CT); or a Minor Subdivision (MS). See Section 2 above for differences.
h. If desired by the client, could this site be eligible for density bonus units?
Staff Response: A density bonus is not restricted to only areas outside of the Coastal Zone.
However, limitations to waivers or incentives may be present if they conflict with coastal
resources defined in the Coastal Act and the City's Local Coastal Program. More specifics
would be needed, but density bonus waivers can be denied if it conflicts with an existing state
law, which includes the Coastal Act. Additionally, a density bonus would only be eligible if the
site provided for density of at least five (5) units. Additionally, while the city would be
required to process a density bonus consistent with state law, the Coastal Development
Permit would be required to be processed by the California Coastal Commission. We would
recommend early coordination on what they would support.
6. The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process for
housing projects. It is not mandatory unless applicants seek the vesting and processing benefits
offered under SB 330. Participation in the SB 330 streamline process would occur first, followed by
the formal development application process required under Government Code (Gov. Code)§§ 65940,
65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by the city of a
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003} -HOOVER STREET SITE
February 25, 2026
Page 5
complete SB 330 Streamline Application {Form P-32) and fee will vest the project for 180 days in
accordance with the ordinances, policies and standards in effect at the time the SB 330 Application is
accepted.
7. Per the Housing Crisis Act of 2019 (SB 330), any project that includes the removal or demolition of a
"protected unit" is required to provide the occupants with 1) relocation benefits (Gov. Code § 7260
et seq.), and 2) right of first refusal for a comparable unit available in the new housing development.
(Gov. Code § 66300 {d)(2)(D).) "Protected units" are generally defined by Gov. Code §
66300(d)(2)(E)(ii) as including residential units subject to affordability restrictions, price controls, or
occupied by low income households. The formal submittal of the project will need to include
documentation regarding any existing "protected units."
8. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal will need to include
a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to
the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric
vehicle charging, water heating and traffic demand management requirements, as set forth in the
California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and
18.51 which is available on the city's website at the following address:
http://www.qcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for grading
or building permits, the project will be required to comply with the effective requirements even if
different than what is proposed in the project's planning approvals. GHG reduction requirements may
impact, but are not limited to, site design and local building code requirements. If incorporating new
GHG reduction requirements results in substantial modifications to the project after planning
approvals are obtained, then prior to issuance of grading or building permits, the applicant may be
required to submit and receive approval of a Consistency Determination or an Amendment
application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please
review all information carefully before submitting.
Land Development Engineering:
1. Please complete a Stormwater Standards Questionnaire Form E-34. Form E-34 will guide you and the
city in determining what type of reports and storm water mitigation must be completed to satisfy
state and City storm water quality requirements. The questionnaire is located on the City of Carlsbad
website:
https://www.carlsbadca.gov/home/showpublisheddocument/604/638683035715330000.
2. Based on a preliminary analysis it appears that this project is a Priority Development Project (PDP). All
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003} -HOOVER STREET SITE
February 25, 2026
Page 6
impervious surfaces being created or replaced (onsite and offsite) shall be included for treatment.
Please submit a Storm Water Quality Management Plan. Review the Hydromodification Exemption
Map and Potential Critical Coarse Sediment Yield Area Map on the City website to see if this criterion
applies to your project. The post construction stormwater treatment BMPs shall be shown on a
conceptual grading plan and drainage plan with the discretionary application.
3. Please provide a Preliminary Title Report (current within the last six (6) months).
4. Please annotate and delineate all existing easements and encumbrances listed in the Preliminary Title
Report on the site plan. Existing city records indicate the property is encumbered by 20-ft sewer
easement made part of the North Agua Hedionda Sewer Realignment (review link below):
https://records.carlsbadca.gov/Weblink/DocView.aspx?id=4790234&dbid=0&repo=C ityofCarlsbad
5. A Preliminary Hydrology Study including map and calculations is required to demonstrate
capacity/sizing of proposed and existing storm drain infrastructure. Please show 100-year storm
hydrologic calculations before and after development for each drainage basin.
6. A Preliminary Geotechnical Report is required to evaluate the feasibility of the project. Guidelines for
preliminary geotechnical studies is available on the City of Carlsbad Engineering website through the
following link:
https://www.carlsbadca.gov/home/showpublisheddocument/326/638054006747270000.
7. Per CMC Section 15.16.060 this project will require a grading permit and grading plan.
8. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey Map
17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical control
per City of Carlsbad Engineering Standards.
9. Please delineate and annotate the limits of grading.
10. Please delineate and annotate approximate topographic contours for existing and proposed
condition. Provide 1-foot contours for slopes less than 5%; 2-foot (2') intervals for slopes between 5%
and 10%, and five-foot (5') intervals for slopes over 10%. Extend contours a minimum 25 feet beyond
the project boundary.
11. On the site plan, please show and identify all existing surface improvements screened back (ac berm,
paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at the project
site, project frontage and within 25 feet of the boundary.
12. Please delineate location of all existing and proposed buildings, walls, fences and permanent
structures onsite and within 25 feet of the site.
13. Please indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project
in cubic yards.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003) -HOOVER STREET SITE
February 25, 2026
Pa e 7
14. Please provide spot elevations at the corners of the pad in the proposed condition. Include finish pad
and floor elevations.
15. Please provide the method of draining the lot. Unless otherwise specified by a geotechnical engineer,
method of drainage shall comply with California Building Code (latest version) section 1804.4.
16. Clearly show and label the 100-year flood line for existing and proposed conditions.
17. Please delineate all walls that will be utilized on the project site and show top of wall and bottom of
wall elevations, including at the highest and lowest points.
18. Please provide chain of title report to determine lot legality. A Certificate of Compliance may be
required pending results of the chain of title documents.
19. Please show existing lot line bearing and distance.
20 . Please provide typical street cross sections for Hoover Street. Provide existing right-of-way width and
existing improvements and proposed improvements and dedications.
21. Please delineate and annotate all proposed driveways and driveway widths.
22. Please show all existing and proposed utilities and callout size for: water, sewer, storm drain,
underground dry utilities, street lights in Hoover Street and laterals affecting the property. Utilize
existing records:
DWG 450-9 (Sewer):
https://records.carlsbadca.gov/Weblink/DocView.aspx?id=5619031&dbid=0&repo=CityofCarlsbad
DWG 278-4 (Water):
https://records .carlsbadca.gov/Weblink/DocView.aspx?id=5446140&dbid=0&repo=CityofCarlsbad
DWG 463-7D (Storm Drain):
https://records.carlsbadca.gov/Weblink/DocView.aspx?id=4594209&dbid=0&repo=CityofCarlsbad
23 . All transformers and electrical facilities solely serving this project site shall be located onsite and
outside of the public right-of-way
24. Please obtain a letter from SDG&E confirming their approval of the proposed transformer location
and stating that no additional off-site facilities will be necessary for this project. Please also include
all existing and proposed dry utilities and the services that will supply power to the proposed
transformer.
25. Public potable water and sewer mains along project frontages must meet minimum design diameter
and material as specified in City of Carlsbad Engineering Standards Vol. 2 Section 3.2.2 for water and
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0001 (DEV2026-0003) -HOOVER STREET SITE
February 25, 2026
Page 8
Volume 1 Section 6.2 for sewer. Utility replacement and/or upsizing may be required as a condition
of development.
26. Please locate fire service, backflows, potable and recycled water services, meters, landscape irrigation
services, and sewer laterals for the new development in compliance with City of Carlsbad Engineering
Standards requirements.
27. Please provide multiple cross-sections of the site to demonstrate differences in grade from adjacent
properties, existing and proposed grades onsite, fences and location of structures onsite and on
adjacent properties.
28. Dedications and frontage improvements are required per CMC Chapter 18.40 and/or CMC Chapter
20.16. A three-foot-wide {3') public street and utility easement shall be dedicated for this project.
29. Hoover Street is designated as an alternative design street. Therefore, this development is not subject
to installing street frontage improvements. The property owner will be required to enter into a
Neighborhood Improvement Agreement (NIA) with the city. The Agreement will be recorded with San
Diego County Recorder's Office.
30. If a vehicle gate will be proposed, a minimum 20 feet from the public right-of-way is required so that
approaching vehicles will not queue in the public right-of-way of Hoover Street.
31. Please be advised that a more in-depth review of the proposed development will occur with the
discretionary permit application and when a more complete design of the project has been provided .
Fire & Life Safety:
1. Fire access shall comply with the current edition of the California Fire Code, as amended by the City
of Carlsbad Municipal Code, and Carlsbad Fire Department Guideline for Fire Access and Water
Supply.
2. Fire hydrants shall be provided along the length of the fire access roadway in the quantities and up to
the maximum distances prescribed in CFC Table C 102.1 and in accordance with the approved Form
P99-F.
Building:
1. No comments.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600